Spelling suggestions: "subject:"ecocardiografia/métodos"" "subject:"ecocardiografias/métodos""
1 |
Determinação do tamanho e extensão do infarto agudo do miocárdio pela ecocardiografia com perfusão em tempo real em seres humanos: comparação com a ressonância magnética / Determination of size and extent of acute myocardial infarction by real time myocardial contrast echocardiography in humans: a comparison with magnetic resonance imagingTrindade, Maria Luciana Zacarias Hannouche da 08 July 2005 (has links)
O objetivo da reperfusão mecânica ou medicamentosa em pacientes com infarto agudo do miocárdio (IAM) é a restauração do fluxo sangüíneo na artéria relacionada ao infarto, a fim de limitar a necrose miocelular e preservar a função contrátil, que são os maiores preditores de sobrevida após o IAM. Entretanto, seu sucesso é indicado pela reperfusão nos capilares miocárdicos e não pela recanalização da artéria relacionada ao infarto. A ecocardiografia com perfusão miocárdica em tempo real pode ser usada para avaliar a perfusão nos capilares miocárdicos e estimar o tamanho do infarto em vários estudos experimentais. O objetivo deste estudo foi determinar a área do miocárdio infartado e sua extensão transmural pela ecocardiografia com perfusão miocárdica em tempo real, em pacientes hospitalizados nos primeiros dias após primo infarto agudo do miocárdio, tendo como padrão de referência a ressonância magnética de perfusão. Prospectivamente, foram estudados 20 pacientes (12 homens), com idade média de 64,2 ± 13,3, dentro de 12 horas de reperfusão mecânica ou medicamentosa. Os exames de ecocardiografia e ressonância magnética foram realizados do segundo ao quinto dia de infarto. O contraste \"PESDA (perfluorocarbon-exposed sonicated dextrose albumin)\" foi administrado em veia periférica, na dose de 0,1ml/Kg, em infusão contínua. A análise ecocardiográfica foi feita por uma análise qualitativa (visual) denominada escala de cinza e por uma análise quantitativa, chamada imagem paramétrica. A área de infarto média foi de 3,03 ± 2,77 cm2 para a escala de cinza (r=0,97), de 3,36 ± 2,82 cm2 para a imagem paramétrica (r= 0,99) e de 3,42 ± 2,80 cm2 para a ressonância magnética. O porcentual médio da área de infarto pela ecocardiografia em escala de cinza foi de 15,22% ± 14,84% (r= 0,97), pela imagem paramétrica foi de 16,46% ± 14,41% (r= 0,99) e pela ressonância magnética foi de 16,76% ± 14,48%. A extensão transmural do infarto em cada segmento infartado pela escala de cinza,apresentou uma correlação menor (r=0,77) em relação à imagem paramétrica (r=0,93). Em conclusão, este estudo mostrou uma excelente correlação entre ecocardiografia com perfusão miocárdica em tempo real (sobretudo pela imagem paramétrica) e ressonância magnética nas medidas da área de infarto e seu porcentual, assim como na determinação de sua extensão transmural em pacientes internados por infarto agudo do miocárdio / The aim of mechanical or pharmacological reperfusion in patients with AMI is to restore blood flow through the infarct related artery in order to limit myocellular necrosis and ultimately preserve myocardial contractile function, which is still the most powerful predictor of survival after acute myocardial infarction. The success of reperfusion, however, is indicated by perfusion of myocardial capillaries rather than simply patency of the infarct related artery. Myocardial contrast echocardiography (MCE) can be used to assess myocardial capillary perfusion and ultimately the infarct size in animals. The aim of this study was to determine by MCE the transmural extent and infarct size using magnetic resonance imaging (MRI) as a gold standard. We prospectively studied 20 patients (12 men; mean age 64.2 ± 13.3) admitted for a first acute myocardial infarction, within 12 hours after mechanical or pharmacological reperfusion. The MCE and MRI were performed between the 3rd and 5th day of acute myocardial infarction (AMI). A suspension of 0.1 ml/kg of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) ultrasound contrast agent was administered as a continuous infusion. The interpretation of perfusion images by MCE was assessed by qualitative analysis (visual- VIS) and a quantitative one called parametric image (PI). The average infarct area showed by VIS was 3.03 ± 2.77 cm 2, by PI was 3.36 ± 2.82 cm 2 and by MRI was 3.42± 2.80cm 2. The average percentage of infarct area by VIS was 15.22% ± 14.84%, by PI was 16.46% ± 14.41% and by MRI was 16.76% ± 14.48%. The transmural extent was calculated in each infarcted segment by VIS, with a worse correlation (r=0,77) than PI (r=0,93). In conclusion, this study showed that MCE, in special PI, correlates well with MRI in detecting infarct size, percentage of infarct size and transmural extent in patients with acute myocardial infarction
|
2 |
Medida do strain bidimensional do ventrículo esquerdo pré-implante percutâneo de endoprótese valvar aórtica: correlação com a evolução após o procedimento / Measurement of bidimensional strain of left ventricle before percutaneous implantation of aortic valve endoprosthesis: correlation with evolution after the procedureFrança, Lucas Arraes de 24 May 2017 (has links)
INTRODUÇÃO: O implante transcateter de prótese valvar aórtica (TAVI) surge nos dias atuais como uma opção terapêutica para os pacientes sintomáticos portadores de estenose aórtica grave. Cerca de 200 mil pacientes em todo o mundo já foram submetidos ao TAVI. Não há grandes estudos que tenham avaliado a correlação prognóstica entre parâmetros ecocardiográficos antes do TAVI e eventos cardiovasculares a longo prazo. É relevante analisar se o strain pré-procedimento e outros parâmetros se comportam como fatores preditores independentes de eventos após o procedimento. MÉTODOS: Foram avaliados, de novembro de 2009 a outubro de 2016, 86 pacientes, submetidos a avaliação ecocardiográfica antes do TAVI e 30 dias após o procedimento, com análise do strain do ventrículo esquerdo pelo speckle tracking bidimensional e outros parâmetros ecocardiográficos. Esses pacientes foram acompanhados clinicamente e avaliados quanto aos desfechos: mortalidade global, mortalidade cardiovascular, classe funcional de insuficiência cardíaca e necessidade de reinternação cardiovascular. RESULTADOS: O strain global longitudinal pré-TAVI reduzido (valor absoluto) aumentou a chance de reinternação cardiovascular (OR: 0,87; 0,77 ±0,99; P= 0,038). A redução da relação E/e´ em 30 dias após o TAVI associou-se à queda da mortalidade global (OR: 0,97; 0,95 ±0,99; P = 0,006), bem como valores elevados pré procedimento dessa relação se associaram a maiores taxas de insuficiência cardíaca classe funcional III ou IV da New York Heart Association após a intervenção (OR: 1,08; 1±1,18; P = 0,049). CONCLUSÃO: Os resultados deste trabalho indicam que o strain global longitudinal pré-procedimento demonstrou ser um preditor de reinternação cardiovascular pós-intervenção a longo prazo. A relação E/e´ pré-procedimento apresentou correlação diretamente proporcional com o desenvolvimento de insuficiência cardíaca classe funcional III ou IV a longo prazo, assim como sua queda acentuada 30 dias após o procedimento correlacionou-se com menor mortalidade global. / INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a therapeutic option for symptomatic patients with severe aortic stenosis. Approximately 200,000 patients around the world have already undergone TAVR. No large studies have evaluated prognostic correlation between echocardiographic parameters before TAVR and long-term cardiovascular events. It is relevant to analyze strain before procedure and how other parameters work as independent predictors of events after the procedure. METHODS: A total of 86 patients were evaluated from November 2009 to October 2016. They underwent echocardiographic evaluation before TAVR and 30 days after the procedure with analysis of strain of the left ventricle by bidimensional speckle tracking and other echocardiographic parameters. Patients were followed clinically and evaluated in relation to outcomes: global mortality, cardiovascular mortality, functional class of heart failure and need for cardiovascular readmissions. RESULTS: Global longitudinal strain before reduced TAVR (absolute value) increased the chance of cardiovascular readmission (odds ratio: 0.87; 0.77 ± 0.99; p = 0.038). Reduction of E/e´ relationship 30 days after TAVI was associated with a drop in global mortality (odds ratio: 0.97; 0.95 ± 0.99; p = 0.006). In addition, high values for this relation before the procedure were associated with higher rates of New York Heart Association functional class III or IV heart failure after the intervention (odds ratio: 1.08; 1.00 ± 1.18; p = 0.049). CONCLUSIONS: Results of this study indicate that global longitudinal strain before the procedure is a predictor of cardiovascular readmission after TAVR. The E/e´relationship before the procedure presented a correlation directly proportional to the development of long-term functional class III or IV heart failure as well as its accentuated drop 30 days after the procedure was correlated with lower global mortality.
|
3 |
Medida do strain bidimensional do ventrículo esquerdo pré-implante percutâneo de endoprótese valvar aórtica: correlação com a evolução após o procedimento / Measurement of bidimensional strain of left ventricle before percutaneous implantation of aortic valve endoprosthesis: correlation with evolution after the procedureLucas Arraes de França 24 May 2017 (has links)
INTRODUÇÃO: O implante transcateter de prótese valvar aórtica (TAVI) surge nos dias atuais como uma opção terapêutica para os pacientes sintomáticos portadores de estenose aórtica grave. Cerca de 200 mil pacientes em todo o mundo já foram submetidos ao TAVI. Não há grandes estudos que tenham avaliado a correlação prognóstica entre parâmetros ecocardiográficos antes do TAVI e eventos cardiovasculares a longo prazo. É relevante analisar se o strain pré-procedimento e outros parâmetros se comportam como fatores preditores independentes de eventos após o procedimento. MÉTODOS: Foram avaliados, de novembro de 2009 a outubro de 2016, 86 pacientes, submetidos a avaliação ecocardiográfica antes do TAVI e 30 dias após o procedimento, com análise do strain do ventrículo esquerdo pelo speckle tracking bidimensional e outros parâmetros ecocardiográficos. Esses pacientes foram acompanhados clinicamente e avaliados quanto aos desfechos: mortalidade global, mortalidade cardiovascular, classe funcional de insuficiência cardíaca e necessidade de reinternação cardiovascular. RESULTADOS: O strain global longitudinal pré-TAVI reduzido (valor absoluto) aumentou a chance de reinternação cardiovascular (OR: 0,87; 0,77 ±0,99; P= 0,038). A redução da relação E/e´ em 30 dias após o TAVI associou-se à queda da mortalidade global (OR: 0,97; 0,95 ±0,99; P = 0,006), bem como valores elevados pré procedimento dessa relação se associaram a maiores taxas de insuficiência cardíaca classe funcional III ou IV da New York Heart Association após a intervenção (OR: 1,08; 1±1,18; P = 0,049). CONCLUSÃO: Os resultados deste trabalho indicam que o strain global longitudinal pré-procedimento demonstrou ser um preditor de reinternação cardiovascular pós-intervenção a longo prazo. A relação E/e´ pré-procedimento apresentou correlação diretamente proporcional com o desenvolvimento de insuficiência cardíaca classe funcional III ou IV a longo prazo, assim como sua queda acentuada 30 dias após o procedimento correlacionou-se com menor mortalidade global. / INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a therapeutic option for symptomatic patients with severe aortic stenosis. Approximately 200,000 patients around the world have already undergone TAVR. No large studies have evaluated prognostic correlation between echocardiographic parameters before TAVR and long-term cardiovascular events. It is relevant to analyze strain before procedure and how other parameters work as independent predictors of events after the procedure. METHODS: A total of 86 patients were evaluated from November 2009 to October 2016. They underwent echocardiographic evaluation before TAVR and 30 days after the procedure with analysis of strain of the left ventricle by bidimensional speckle tracking and other echocardiographic parameters. Patients were followed clinically and evaluated in relation to outcomes: global mortality, cardiovascular mortality, functional class of heart failure and need for cardiovascular readmissions. RESULTS: Global longitudinal strain before reduced TAVR (absolute value) increased the chance of cardiovascular readmission (odds ratio: 0.87; 0.77 ± 0.99; p = 0.038). Reduction of E/e´ relationship 30 days after TAVI was associated with a drop in global mortality (odds ratio: 0.97; 0.95 ± 0.99; p = 0.006). In addition, high values for this relation before the procedure were associated with higher rates of New York Heart Association functional class III or IV heart failure after the intervention (odds ratio: 1.08; 1.00 ± 1.18; p = 0.049). CONCLUSIONS: Results of this study indicate that global longitudinal strain before the procedure is a predictor of cardiovascular readmission after TAVR. The E/e´relationship before the procedure presented a correlation directly proportional to the development of long-term functional class III or IV heart failure as well as its accentuated drop 30 days after the procedure was correlated with lower global mortality.
|
4 |
Determinação do tamanho e extensão do infarto agudo do miocárdio pela ecocardiografia com perfusão em tempo real em seres humanos: comparação com a ressonância magnética / Determination of size and extent of acute myocardial infarction by real time myocardial contrast echocardiography in humans: a comparison with magnetic resonance imagingMaria Luciana Zacarias Hannouche da Trindade 08 July 2005 (has links)
O objetivo da reperfusão mecânica ou medicamentosa em pacientes com infarto agudo do miocárdio (IAM) é a restauração do fluxo sangüíneo na artéria relacionada ao infarto, a fim de limitar a necrose miocelular e preservar a função contrátil, que são os maiores preditores de sobrevida após o IAM. Entretanto, seu sucesso é indicado pela reperfusão nos capilares miocárdicos e não pela recanalização da artéria relacionada ao infarto. A ecocardiografia com perfusão miocárdica em tempo real pode ser usada para avaliar a perfusão nos capilares miocárdicos e estimar o tamanho do infarto em vários estudos experimentais. O objetivo deste estudo foi determinar a área do miocárdio infartado e sua extensão transmural pela ecocardiografia com perfusão miocárdica em tempo real, em pacientes hospitalizados nos primeiros dias após primo infarto agudo do miocárdio, tendo como padrão de referência a ressonância magnética de perfusão. Prospectivamente, foram estudados 20 pacientes (12 homens), com idade média de 64,2 ± 13,3, dentro de 12 horas de reperfusão mecânica ou medicamentosa. Os exames de ecocardiografia e ressonância magnética foram realizados do segundo ao quinto dia de infarto. O contraste \"PESDA (perfluorocarbon-exposed sonicated dextrose albumin)\" foi administrado em veia periférica, na dose de 0,1ml/Kg, em infusão contínua. A análise ecocardiográfica foi feita por uma análise qualitativa (visual) denominada escala de cinza e por uma análise quantitativa, chamada imagem paramétrica. A área de infarto média foi de 3,03 ± 2,77 cm2 para a escala de cinza (r=0,97), de 3,36 ± 2,82 cm2 para a imagem paramétrica (r= 0,99) e de 3,42 ± 2,80 cm2 para a ressonância magnética. O porcentual médio da área de infarto pela ecocardiografia em escala de cinza foi de 15,22% ± 14,84% (r= 0,97), pela imagem paramétrica foi de 16,46% ± 14,41% (r= 0,99) e pela ressonância magnética foi de 16,76% ± 14,48%. A extensão transmural do infarto em cada segmento infartado pela escala de cinza,apresentou uma correlação menor (r=0,77) em relação à imagem paramétrica (r=0,93). Em conclusão, este estudo mostrou uma excelente correlação entre ecocardiografia com perfusão miocárdica em tempo real (sobretudo pela imagem paramétrica) e ressonância magnética nas medidas da área de infarto e seu porcentual, assim como na determinação de sua extensão transmural em pacientes internados por infarto agudo do miocárdio / The aim of mechanical or pharmacological reperfusion in patients with AMI is to restore blood flow through the infarct related artery in order to limit myocellular necrosis and ultimately preserve myocardial contractile function, which is still the most powerful predictor of survival after acute myocardial infarction. The success of reperfusion, however, is indicated by perfusion of myocardial capillaries rather than simply patency of the infarct related artery. Myocardial contrast echocardiography (MCE) can be used to assess myocardial capillary perfusion and ultimately the infarct size in animals. The aim of this study was to determine by MCE the transmural extent and infarct size using magnetic resonance imaging (MRI) as a gold standard. We prospectively studied 20 patients (12 men; mean age 64.2 ± 13.3) admitted for a first acute myocardial infarction, within 12 hours after mechanical or pharmacological reperfusion. The MCE and MRI were performed between the 3rd and 5th day of acute myocardial infarction (AMI). A suspension of 0.1 ml/kg of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) ultrasound contrast agent was administered as a continuous infusion. The interpretation of perfusion images by MCE was assessed by qualitative analysis (visual- VIS) and a quantitative one called parametric image (PI). The average infarct area showed by VIS was 3.03 ± 2.77 cm 2, by PI was 3.36 ± 2.82 cm 2 and by MRI was 3.42± 2.80cm 2. The average percentage of infarct area by VIS was 15.22% ± 14.84%, by PI was 16.46% ± 14.41% and by MRI was 16.76% ± 14.48%. The transmural extent was calculated in each infarcted segment by VIS, with a worse correlation (r=0,77) than PI (r=0,93). In conclusion, this study showed that MCE, in special PI, correlates well with MRI in detecting infarct size, percentage of infarct size and transmural extent in patients with acute myocardial infarction
|
5 |
Avaliação da função sistólica biventricular pelo speckle tracking em pacientes com anemia falciforme / Evaluation of biventricular systolic function by speckle tracking in patients with homozygous sickle cell anemiaBraga, João Carlos Moron Saes 28 July 2014 (has links)
Introdução: A doença falciforme (DF) é a afecção hematológica hereditária de maior prevalência no mundo, sendo que a anemia falciforme (AF) é a forma mais grave com elevada morbidade e mortalidade. Alterações cardíacas são reconhecidamente associadas à AF, como aumento cavitário, hipertensão arterial pulmonar e disfunção diastólica do ventrículo esquerdo. No entanto, ainda não existe consenso quanto à função sistólica ventricular nesses pacientes. O objetivo deste estudo foi o de investigar a função ventricular de pacientes com anemia falciforme utilizando o strain e o twist ventricular obtidos pelo speckle tracking bidimensional, e reconhecer os indivíduos sob maior risco cardiovascular, em que a instituição precoce de tratamento específico poderá beneficiar essa população. Métodos: Foram recrutados 40 pacientes com anemia falciforme (23,5 ± 9,3 anos; 24 homens) e 40 controles saudáveis pareados por sexo e idade, submetidos à entrevista estruturada, ecocardiograma transtorácico, cintilografia pulmonar ventilação perfusão e coleta de amostras de sangue. Todos os indivíduos foram submetidos à avaliação ecocardiográfica convencional padrão e subsequente avaliação offline do strain sistólico biventricular e estudo rotacional do ventrículo esquerdo utilizando speckle-tracking ecocardiográfico. Resultados: Os pacientes com AF apresentaram volume do VE indexado, massa do VE indexado, pressão arterial pulmonar e E/E\' médio superiores aos controles. As medidas de FE do VE, excursão sistólica do plano da tricúspide (TAPSE), Strain Global do VE (longitudinal, circunferencial, radial) e Strain Global do VD (longitudinal) não evidenciaram diferenças entre os grupos. Twist VE se mostrou reduzido em comparação aos controles (7,4 ± 1,2? vs 10,7 ± 1,8? , P <0,0001 ) e Tempo de pico de rotação apical prolongado (366,7 ± 26,1ms vs 344,6 ± 11,7ms , P <0,0001 ). Algumas variáveis se mostraram fortemente relacionadas ao twist VE, como índice de gravidade clínico (Rho= - 0,97, Z value= - 6,05, P < 0,0001), relação E/E\' médio (r = 0,94, F valor= 156.9, p<0,0001), IVDFVE (índice do volume diastólico final do ventrículo esquerdo)(r = 0,81 e p<0,0001) e pressão sistólica arterial pulmonar (r = 0,72 e p<0,0001). Conclusões: Os resultados deste trabalho indicam que o twist ventricular esquerdo derivado do speckle tracking bidimensional encontra-se alterado em pacientes com anemia falciforme e função sistólica ventricular preservada, avaliada pela metodologia convencional, e existe forte correlação entre o twist ventricular esquerdo e o índice clínico de gravidade, relação E/E\', índice do volume diastólico final do ventrículo esquerdo e pressão sistólica arterial pulmonar. / Background: Sickle cell disease (SCD) is the most prevalent hematological condition in the world, with sickle cell anemia (SCA) being its most serious form, displaying a high level of morbidity and mortality. Cardiac changes are known to be associated with SCA, including an increase in cardiac chamber size, pulmonary hypertension and left ventricle diastolic dysfunction. However, there is still no consensus regarding the ventricular systolic function in these patients. The purpose of this study is to investigate the ventricular function of patients with sickle cell anemia utilizing the strain and ventricular twist, obtained by two-dimensional speckle tracking, as well as to identify individuals with higher cardiovascular risk, in which early application of specific treatment could benefit this group of people. Methods: 40 patients were recruited with sickle cell anemia (ages 23.5 ± 9.3 years; 24 males) and 40 healthy control individuals paired by gender and age, submitted to structured interviews, transthoracic echocardiogram, pulmonary scintigraphy and collection of blood samples. All individuals were submitted to a standard echocardiographic evaluation and subsequent off line evaluation of the biventricular systolic strain and rotational study of the left ventricle using echocardiographic speckle-tracking. Results: Patients with SCA presented LV volume indices, LV mass Indices, pulmonary arterial pressure and E/ E\' ratios statistically higher than the control individuals. Measurements of Ejection Fraction (EF) of the left ventricle, tricuspid annular plane systolic excursion (TAPSE), Overall LV Strain (Longitudinal, Circumferential, and Radial) and Overall RV Strain (Longitudinal) did not present differences between the groups. LV twist was significantly lower in relation to the control group (7,4 ± 1,2? vs 10,7 ± 1,8? , P <0,0001 ) and prolonged time to peak apical rotation (366.7 ± 26.1ms vs 344.6 ± 11.7ms , P <0.0001 ). In addition, some variables showed themselves to be strongly related to LV twist such as the clinical severity index ( Rho= - 0.97, Z value= - 6.05, P < 0.0001), E/E\' Ratio (r = 0.94, F value=156.9 e p<0.0001) ), left ventricle end diastolic volume index (LVEDV index) (r = 0,81, p<0,0001) and pulmonary systolic arterial pressure (r = 0.72 e p<0.0001). Conclusions: The results of this study indicate that the left ventricular twist derived from two-dimensional speckle tracking is altered in patients with sickle cell anemia and a preserved ventricular systolic function, evaluated using conventional methodology and that there is a strong correlation between left ventricular twist and the clinical severity index, E/E\' ratio, left ventricle end diastolic volume index and the pulmonary systolic arterial pressure.
|
6 |
Efetividade clínica e segurança do tratamento percutâneo da comunicação interatrial tipo ostium secundum com a prótese Amplatzer / Efficacy and safety of percutaneous treatment of the secundum atrial septal defect with the Amplatzer® prosthesisBraga, Sergio Luiz Navarro 10 September 2003 (has links)
O fechamento percutâneo da comunicação interatrial tipo ostium secundum, tem se constituído no método terapêutico alternativo ao tratamento cirúrgico. A presente investigação avaliou a prótese autocentrável Amplatzer. na oclusão desses defeitos, sob a hipótese da eficácia e segurança desta nova concepção instrumental. Para tanto, averiguamos: o porcentual de sucesso técnico, a presença e quantificação do fluxo residual imediato e sua evolução e o impacto do tratamento nas dimensões do ventrículo direito. A casuística foi de 49 pacientes, com a idade variando de 3,4 a 56,2 anos (mediana de 13,3 anos) e 59,2% eram do sexo feminino. O ritmo sinusal esteve presente em 96% dos casos e 85,7% destes evidenciaram índice cardiotorácico > 0,50. O defeito apresentou-se como orifício único em 91,8% dos casos. A borda ântero-superior era deficiente em 40,6% e as médias dos diâmetros longitudinal e transverso corresponderam a 14,3 mm (DP = 5,0 mm) e 14,4 mm (DP = 4,9 mm). A relação fluxo pulmonar / fluxo sistêmico oscilou entre 1,2 a 3,5 [média 2,0 (DP = 1,4)]. A média dos diâmetros estirados foi de 19,3 mm (DP = 5,1 mm) e o das próteses empregadas de 20,3 mm (DP = 4,9 mm). Houve sucesso técnico em 97,9%. A média dos tempos do procedimento foi de 73,8 min (DP = 30,9 min). A única complicação imediata foi taquicardia supraventricular paroxística em 6,1% dos casos. Observou-se fluxo residual imediato em 54,1% dos casos, (45,8% mínimos ou pequenos e 8,3% moderados) caindo para 25% após 24 horas (p = 0,0002). Neste mesmo período houve também diminuição dos pacientes com índice cardiotorácico > 0,50 de 85,7% para 68,4% (p = 0,016). Ao final de 13,1 meses (DP = 1,3 meses) a incidência do fluxo residual reduziu-se para 14,6%, sendo apenas 4,1% moderados. Houve redução significante do diâmetro diastólico do ventrículo direito nas diversas fases do seguimento clínico (p < 0,001). Conclusões: o porcentual de sucesso técnico com o dispositivo Amplatzer® foi alto (97,9%); a incidência de fluxo residual tardio foi de 14,6%; houve redução progressiva e importante do índice cardiotorácico > 0,50 em conseqüência da diminuição significante e progressiva das dimensões do ventrículo direito, o qual atingiu normalização entre o 3º e o 12º meses. As evidências foram de que o dispositivo Amplatzer® permaneceu estável e incorporado ao septo interatrial ao final da observação constituindo-se numa opção segura e eficaz para o tratamento de casos selecionados / Percutaneous closure of the secundum atrial septal defect has been employed as an alternative to surgical treatment. The present investigation evaluated the safety and efficacy of the Amplatzer. prosthesis in the treatment of such defects. For that, we assessed the presence and magnitude of immediate and follow-up residual shunting, the rate of technical success and its impact on the right ventricle. Forty-nine patients with a maximal defect diameter of ¡Ü 30 mm and left-to-right shunting were studied. Age varied from 3.4 to 56.2 years (median of 13.3 years) and 59% were female. Sinus rhythm was present in 96% of cases and 85.7% had a cardiothoracic index of > 0.50. There was a single defect in 91.8% of cases. The anterosuperior rim was deficient in 40.6% and the mean longitudinal and transverse diameters were 14.3 mm (SD = 5.0 mm) and 14.4 mm (SD = 4.9 mm), respectively. The pulmonary to systemic flow ratio varied from 1.2 to 3.5 [mean of 2.0 (SD = 1.4)]. The mean stretched and device diameters were 19.3 mm (SD 5.1 mm) and 20.3 mm (SD = 4.9 mm), respectively. Technical success was achieved in 97.9%. The mean procedure time was 73.8 minutes (SD = 30.9 min). Supraventricular tachycardia was the only complication in 6.1% of cases. Immediate residual shunt was observed in 54.1% of cases (trivial to mild in 45.8% and moderate in 8.3%) falling to 25% after 24 hours (p = 0.0002). At this time, there was also a decrease in the percentage of patients with a cardiothoracic index > 0.50 from 85.7% to 68.4% (p = 0,016). After 13.1 months (SD = 1.3 months) the incidence of residual shunting decreased to 14.6%, being moderate in only 4.1%. There was a significant reduction in the end-diastolic diameter of the right ventricle during follow-up (p < 0,001). Conclusions: the rate of technical success with the Amplatzer® device was high (97.9%); the rate of late residual shunting was 14.6%; there was a progressive and important reduction in the cardiothoracic index > 0.50 as a consequence of the significant and progressive reduction in the dimensions of the right ventricle, which reached normal values between the 3rd and 12th month. At the end of the study, the Amplatzer® device remained stable within the interatrial septum and was incorporated to it, being considered as a safe and effective option in the treatment of selected cases.
|
7 |
Acurácia diagnóstica da ecocardiografia sob estresse associada ao estudo da perfusão miocárdica com contraste na avaliação da isquemia miocárdica: estudo comparativo entre adenosina e dobutamina / Diagnostic accuracy of quantitative real time myocardial contrast echocardiography for the detection of myocardial ischemia. A comparative study between adenosine and dobutamineKowatsch, Ingrid 23 August 2005 (has links)
A ecocardiografia com perfusão miocárdica em tempo real (EPMTR) permite a quantificação do fluxo sangüíneo miocárdico e, quando realizada durante o estresse, da reserva de fluxo miocárdico (reserva Axß). Essa técnica tem potencial para ser uma importante ferramenta para o diagnóstico não-invasivo da doença arterial coronariana (DAC). Apesar do conhecimento atual das alterações fisiológicas que ocorrem com o uso de agentes vasodilatadores ou catecolaminas na circulação coronariana, não há dados na literatura comparando diretamente o valor da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de DAC em humanos. Os objetivos deste estudo foram: avaliar, em um mesmo grupo de pacientes, a exeqüibilidade e a acurácia da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de estenose arterial coronariana angiograficamente significativa e determinar o valor adicional da análise quantitativa da perfusão miocárdica sobre o eletrocardiograma de 12 derivações, da motilidade segmentar e da análise qualitativa da perfusão miocárdica obtidas durante o estresse pela dobutamina e pela adenosina. Estudamos 54 pacientes (média etária de 60±9 anos, 33 homens) com suspeita clínica de DAC e indicação de angiografia coronariana. Todos os pacientes foram submetidos à EPMTR sob estresse pela adenosina na dose de 140 g/kg/min por seis minutos e, após um intervalo de três a cinco horas, à EPMTR sob estresse pela dobutamina-atropina. O contraste ecocardiográfico utilizado foi o PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin), administrado por via intravenosa periférica de forma contínua. Para ambas as EPMTR sob estresse pela dobutamina e pela adenosina, foram feitas análises do eletrocardiograma em 12 derivações (ECG), da motilidade segmentar e análise qualitativa e quantitativa da perfusão miocárdica. A quantificação da velocidade do fluxo miocárdico (ß) e do fluxo sangüíneo miocárdico (Axß) foi realizada por meio da utilização do programa computacional QLab 3.0 (Philips Medical Systems, Bothell, WA, USA). Todos os pacientes foram submetidos à angiografia coronariana quantitativa (ACQ) em um intervalo de até 30 dias da EPMTR. Foi considerada DAC a presença de lesão coronariana > 50% do diâmetro luminal. Dos 54 pacientes estudados, 25 (46%) apresentaram lesão coronariana >50% e 29 (54%) não apresentaram lesão coronariana significativa. A exeqüibilidade da quantificação da reserva Axß foi semelhante para a EPMTR sob estresse pela adenosina e pela dobutamina (91% versus 90% dos territórios arteriais; p = ns). A variabilidade da quantificação interobservador para os parâmetros de reserva ß e Axß foi de 6,8% (r = 0,98) e 5,5% (r = 0,97), respectivamente. A variabilidade intra-observador para os mesmos parâmetros foi de 2,1 % (r = 0,99) e 7,4 % (r = 0,95), respectivamente. A análise quantitativa da perfusão miocárdica, obtida pela EPMTR sob estresse pela dobutamina, apresentou sensibilidade de 84%, especificidade de 76% e acurácia de 80% para a detecção de DAC, enquanto que a EPMTR sob estresse pela adenosina apresentou sensibilidade de 88%, especificidade de 72% e acurácia de 80%. O valor incremental das modalidades estudadas para o diagnóstico de DAC foi analisado em modelo que incluiu o ECG, ECG e motilidade segmentar, ECG e motilidade segmentar e perfusão qualitativa e, por último, ECG e motilidade segmentar e perfusão qualitativa e quantitava, tanto para a EPMTR sob estresse pela dobutamina como pela adenosina (2 de 4,9 versus 20,1 versus 23,7 versus 38,4) e (2 de 9,9 versus 20,1 versus 26,7 versus 59,4), respectivamente. Concluímos que a avaliação quantitativa da EPMTR apresenta boa exeqüibilidade. A EPMTR sob estresse pela dobutamina e a pela adenosina apresentam acurácias diagnósticas similares para a detecção de lesão angiograficamente significativa. A análise quantitativa da perfusão miocárdica apresenta valor diagnóstico adicional aos outros parâmetros obtidos durante o estresse pela dobutamina e adenosina. / Real time myocardial contrast echocardiography (RTMCE) has allowed for the quantification of myocardial blood flow reserve (MBFR). This technique is a valuable tool for the noninvasive detection of coronary artery disease (CAD). Both adenosine and dobutamine are currently used stressor agents during RTMCE. Although it has already been shown the effects of these drugs on the coronary physiology, no study has directly compared both agents during RTMCE. The aims of this study were to determine the feasibility and diagnostic accuracy of adenosine versus dobutamine stress RTMCE for the detection of angiographically significant CAD. In addition, we sought to determine the additional value of quantitative RTMCE over the electrocardiogram, wall motion, and qualitative analysis of myocardial perfusion. The study involved 54 patients (60±9 years, 33 men) with suspected CAD. Patients underwent RTMCE at rest and during continuous infusion of 140g/kg/min of adenosine for six minutes, and dobutamine stress. The contrast agent used in the study was PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin) administered in continuous intravenous infusion. Quantification of plateau of acoustic intensity (A) and microbubble velocity () was performed off line using a specific software (QLab 3.0, Philips Medical Systems, Bothell, WA, USA). Myocardial blood flow was determined as Ax. Quantitative coronary angiography was performed in all patients within 30 days of RTMCE, and CAD was defined as >50% luminal diameter coronary stenosis. There were 25 (46%) patients with CAD and 29 (54%) patients without obstructive lesion. The feasibility of quantitative MBFR was the same for adenosine and dobutamine stress RTMCE (91% versus 90% in all arterial territories; p=ns). The intraobserver variabilities for the measurements of ß and Axß reserve were 2.1% (r = 0.99) and 7.4% (r = 0.95), respectively. The interobserver variabilities for the same parameters were 6.8% (r = 0.98) and 5.5% (r = 0.97), respectively. The sensitivity, specificity and diagnostic accuracy of ß reserve obtained during dobutamine stress RTMCE for detecting CAD were 84%, 76%, and 80%, respectively, and during adenosine stress RTMCE they were 88%, 72% and 80%. The incremental value for the diagnosis of CAD was analyzed in a model that included the EKG, EKG and wall motion, EKG and wall motion and qualitative perfusion analysis and finally, EKG and wall motion and qualitative and quantitative perfusion analysis, for dobutamine and adenosine RTMCE (2= 4,9 versus 20,1 versus 23,7 versus s 38,4) and (2= 9,9 versus 20,1 versus 26,7 versus 59,4), respectively. In conclusion, quantitative RTMCE is a feasible technique in patients with suspected CAD. Dobutamine and adenosine stress RTMCE had similar diagnostic accuracy for the detection of angiographically significant lesion. Quantitative analysis of myocardial perfusion had incremental diagnostic value over the other parameters obtained during both dobutamine and adenosine stress RTMCE.
|
8 |
Avaliação da função sistólica biventricular pelo speckle tracking em pacientes com anemia falciforme / Evaluation of biventricular systolic function by speckle tracking in patients with homozygous sickle cell anemiaJoão Carlos Moron Saes Braga 28 July 2014 (has links)
Introdução: A doença falciforme (DF) é a afecção hematológica hereditária de maior prevalência no mundo, sendo que a anemia falciforme (AF) é a forma mais grave com elevada morbidade e mortalidade. Alterações cardíacas são reconhecidamente associadas à AF, como aumento cavitário, hipertensão arterial pulmonar e disfunção diastólica do ventrículo esquerdo. No entanto, ainda não existe consenso quanto à função sistólica ventricular nesses pacientes. O objetivo deste estudo foi o de investigar a função ventricular de pacientes com anemia falciforme utilizando o strain e o twist ventricular obtidos pelo speckle tracking bidimensional, e reconhecer os indivíduos sob maior risco cardiovascular, em que a instituição precoce de tratamento específico poderá beneficiar essa população. Métodos: Foram recrutados 40 pacientes com anemia falciforme (23,5 ± 9,3 anos; 24 homens) e 40 controles saudáveis pareados por sexo e idade, submetidos à entrevista estruturada, ecocardiograma transtorácico, cintilografia pulmonar ventilação perfusão e coleta de amostras de sangue. Todos os indivíduos foram submetidos à avaliação ecocardiográfica convencional padrão e subsequente avaliação offline do strain sistólico biventricular e estudo rotacional do ventrículo esquerdo utilizando speckle-tracking ecocardiográfico. Resultados: Os pacientes com AF apresentaram volume do VE indexado, massa do VE indexado, pressão arterial pulmonar e E/E\' médio superiores aos controles. As medidas de FE do VE, excursão sistólica do plano da tricúspide (TAPSE), Strain Global do VE (longitudinal, circunferencial, radial) e Strain Global do VD (longitudinal) não evidenciaram diferenças entre os grupos. Twist VE se mostrou reduzido em comparação aos controles (7,4 ± 1,2? vs 10,7 ± 1,8? , P <0,0001 ) e Tempo de pico de rotação apical prolongado (366,7 ± 26,1ms vs 344,6 ± 11,7ms , P <0,0001 ). Algumas variáveis se mostraram fortemente relacionadas ao twist VE, como índice de gravidade clínico (Rho= - 0,97, Z value= - 6,05, P < 0,0001), relação E/E\' médio (r = 0,94, F valor= 156.9, p<0,0001), IVDFVE (índice do volume diastólico final do ventrículo esquerdo)(r = 0,81 e p<0,0001) e pressão sistólica arterial pulmonar (r = 0,72 e p<0,0001). Conclusões: Os resultados deste trabalho indicam que o twist ventricular esquerdo derivado do speckle tracking bidimensional encontra-se alterado em pacientes com anemia falciforme e função sistólica ventricular preservada, avaliada pela metodologia convencional, e existe forte correlação entre o twist ventricular esquerdo e o índice clínico de gravidade, relação E/E\', índice do volume diastólico final do ventrículo esquerdo e pressão sistólica arterial pulmonar. / Background: Sickle cell disease (SCD) is the most prevalent hematological condition in the world, with sickle cell anemia (SCA) being its most serious form, displaying a high level of morbidity and mortality. Cardiac changes are known to be associated with SCA, including an increase in cardiac chamber size, pulmonary hypertension and left ventricle diastolic dysfunction. However, there is still no consensus regarding the ventricular systolic function in these patients. The purpose of this study is to investigate the ventricular function of patients with sickle cell anemia utilizing the strain and ventricular twist, obtained by two-dimensional speckle tracking, as well as to identify individuals with higher cardiovascular risk, in which early application of specific treatment could benefit this group of people. Methods: 40 patients were recruited with sickle cell anemia (ages 23.5 ± 9.3 years; 24 males) and 40 healthy control individuals paired by gender and age, submitted to structured interviews, transthoracic echocardiogram, pulmonary scintigraphy and collection of blood samples. All individuals were submitted to a standard echocardiographic evaluation and subsequent off line evaluation of the biventricular systolic strain and rotational study of the left ventricle using echocardiographic speckle-tracking. Results: Patients with SCA presented LV volume indices, LV mass Indices, pulmonary arterial pressure and E/ E\' ratios statistically higher than the control individuals. Measurements of Ejection Fraction (EF) of the left ventricle, tricuspid annular plane systolic excursion (TAPSE), Overall LV Strain (Longitudinal, Circumferential, and Radial) and Overall RV Strain (Longitudinal) did not present differences between the groups. LV twist was significantly lower in relation to the control group (7,4 ± 1,2? vs 10,7 ± 1,8? , P <0,0001 ) and prolonged time to peak apical rotation (366.7 ± 26.1ms vs 344.6 ± 11.7ms , P <0.0001 ). In addition, some variables showed themselves to be strongly related to LV twist such as the clinical severity index ( Rho= - 0.97, Z value= - 6.05, P < 0.0001), E/E\' Ratio (r = 0.94, F value=156.9 e p<0.0001) ), left ventricle end diastolic volume index (LVEDV index) (r = 0,81, p<0,0001) and pulmonary systolic arterial pressure (r = 0.72 e p<0.0001). Conclusions: The results of this study indicate that the left ventricular twist derived from two-dimensional speckle tracking is altered in patients with sickle cell anemia and a preserved ventricular systolic function, evaluated using conventional methodology and that there is a strong correlation between left ventricular twist and the clinical severity index, E/E\' ratio, left ventricle end diastolic volume index and the pulmonary systolic arterial pressure.
|
9 |
Acurácia diagnóstica da ecocardiografia sob estresse associada ao estudo da perfusão miocárdica com contraste na avaliação da isquemia miocárdica: estudo comparativo entre adenosina e dobutamina / Diagnostic accuracy of quantitative real time myocardial contrast echocardiography for the detection of myocardial ischemia. A comparative study between adenosine and dobutamineIngrid Kowatsch 23 August 2005 (has links)
A ecocardiografia com perfusão miocárdica em tempo real (EPMTR) permite a quantificação do fluxo sangüíneo miocárdico e, quando realizada durante o estresse, da reserva de fluxo miocárdico (reserva Axß). Essa técnica tem potencial para ser uma importante ferramenta para o diagnóstico não-invasivo da doença arterial coronariana (DAC). Apesar do conhecimento atual das alterações fisiológicas que ocorrem com o uso de agentes vasodilatadores ou catecolaminas na circulação coronariana, não há dados na literatura comparando diretamente o valor da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de DAC em humanos. Os objetivos deste estudo foram: avaliar, em um mesmo grupo de pacientes, a exeqüibilidade e a acurácia da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de estenose arterial coronariana angiograficamente significativa e determinar o valor adicional da análise quantitativa da perfusão miocárdica sobre o eletrocardiograma de 12 derivações, da motilidade segmentar e da análise qualitativa da perfusão miocárdica obtidas durante o estresse pela dobutamina e pela adenosina. Estudamos 54 pacientes (média etária de 60±9 anos, 33 homens) com suspeita clínica de DAC e indicação de angiografia coronariana. Todos os pacientes foram submetidos à EPMTR sob estresse pela adenosina na dose de 140 g/kg/min por seis minutos e, após um intervalo de três a cinco horas, à EPMTR sob estresse pela dobutamina-atropina. O contraste ecocardiográfico utilizado foi o PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin), administrado por via intravenosa periférica de forma contínua. Para ambas as EPMTR sob estresse pela dobutamina e pela adenosina, foram feitas análises do eletrocardiograma em 12 derivações (ECG), da motilidade segmentar e análise qualitativa e quantitativa da perfusão miocárdica. A quantificação da velocidade do fluxo miocárdico (ß) e do fluxo sangüíneo miocárdico (Axß) foi realizada por meio da utilização do programa computacional QLab 3.0 (Philips Medical Systems, Bothell, WA, USA). Todos os pacientes foram submetidos à angiografia coronariana quantitativa (ACQ) em um intervalo de até 30 dias da EPMTR. Foi considerada DAC a presença de lesão coronariana > 50% do diâmetro luminal. Dos 54 pacientes estudados, 25 (46%) apresentaram lesão coronariana >50% e 29 (54%) não apresentaram lesão coronariana significativa. A exeqüibilidade da quantificação da reserva Axß foi semelhante para a EPMTR sob estresse pela adenosina e pela dobutamina (91% versus 90% dos territórios arteriais; p = ns). A variabilidade da quantificação interobservador para os parâmetros de reserva ß e Axß foi de 6,8% (r = 0,98) e 5,5% (r = 0,97), respectivamente. A variabilidade intra-observador para os mesmos parâmetros foi de 2,1 % (r = 0,99) e 7,4 % (r = 0,95), respectivamente. A análise quantitativa da perfusão miocárdica, obtida pela EPMTR sob estresse pela dobutamina, apresentou sensibilidade de 84%, especificidade de 76% e acurácia de 80% para a detecção de DAC, enquanto que a EPMTR sob estresse pela adenosina apresentou sensibilidade de 88%, especificidade de 72% e acurácia de 80%. O valor incremental das modalidades estudadas para o diagnóstico de DAC foi analisado em modelo que incluiu o ECG, ECG e motilidade segmentar, ECG e motilidade segmentar e perfusão qualitativa e, por último, ECG e motilidade segmentar e perfusão qualitativa e quantitava, tanto para a EPMTR sob estresse pela dobutamina como pela adenosina (2 de 4,9 versus 20,1 versus 23,7 versus 38,4) e (2 de 9,9 versus 20,1 versus 26,7 versus 59,4), respectivamente. Concluímos que a avaliação quantitativa da EPMTR apresenta boa exeqüibilidade. A EPMTR sob estresse pela dobutamina e a pela adenosina apresentam acurácias diagnósticas similares para a detecção de lesão angiograficamente significativa. A análise quantitativa da perfusão miocárdica apresenta valor diagnóstico adicional aos outros parâmetros obtidos durante o estresse pela dobutamina e adenosina. / Real time myocardial contrast echocardiography (RTMCE) has allowed for the quantification of myocardial blood flow reserve (MBFR). This technique is a valuable tool for the noninvasive detection of coronary artery disease (CAD). Both adenosine and dobutamine are currently used stressor agents during RTMCE. Although it has already been shown the effects of these drugs on the coronary physiology, no study has directly compared both agents during RTMCE. The aims of this study were to determine the feasibility and diagnostic accuracy of adenosine versus dobutamine stress RTMCE for the detection of angiographically significant CAD. In addition, we sought to determine the additional value of quantitative RTMCE over the electrocardiogram, wall motion, and qualitative analysis of myocardial perfusion. The study involved 54 patients (60±9 years, 33 men) with suspected CAD. Patients underwent RTMCE at rest and during continuous infusion of 140g/kg/min of adenosine for six minutes, and dobutamine stress. The contrast agent used in the study was PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin) administered in continuous intravenous infusion. Quantification of plateau of acoustic intensity (A) and microbubble velocity () was performed off line using a specific software (QLab 3.0, Philips Medical Systems, Bothell, WA, USA). Myocardial blood flow was determined as Ax. Quantitative coronary angiography was performed in all patients within 30 days of RTMCE, and CAD was defined as >50% luminal diameter coronary stenosis. There were 25 (46%) patients with CAD and 29 (54%) patients without obstructive lesion. The feasibility of quantitative MBFR was the same for adenosine and dobutamine stress RTMCE (91% versus 90% in all arterial territories; p=ns). The intraobserver variabilities for the measurements of ß and Axß reserve were 2.1% (r = 0.99) and 7.4% (r = 0.95), respectively. The interobserver variabilities for the same parameters were 6.8% (r = 0.98) and 5.5% (r = 0.97), respectively. The sensitivity, specificity and diagnostic accuracy of ß reserve obtained during dobutamine stress RTMCE for detecting CAD were 84%, 76%, and 80%, respectively, and during adenosine stress RTMCE they were 88%, 72% and 80%. The incremental value for the diagnosis of CAD was analyzed in a model that included the EKG, EKG and wall motion, EKG and wall motion and qualitative perfusion analysis and finally, EKG and wall motion and qualitative and quantitative perfusion analysis, for dobutamine and adenosine RTMCE (2= 4,9 versus 20,1 versus 23,7 versus s 38,4) and (2= 9,9 versus 20,1 versus 26,7 versus 59,4), respectively. In conclusion, quantitative RTMCE is a feasible technique in patients with suspected CAD. Dobutamine and adenosine stress RTMCE had similar diagnostic accuracy for the detection of angiographically significant lesion. Quantitative analysis of myocardial perfusion had incremental diagnostic value over the other parameters obtained during both dobutamine and adenosine stress RTMCE.
|
10 |
Efetividade clínica e segurança do tratamento percutâneo da comunicação interatrial tipo ostium secundum com a prótese Amplatzer / Efficacy and safety of percutaneous treatment of the secundum atrial septal defect with the Amplatzer® prosthesisSergio Luiz Navarro Braga 10 September 2003 (has links)
O fechamento percutâneo da comunicação interatrial tipo ostium secundum, tem se constituído no método terapêutico alternativo ao tratamento cirúrgico. A presente investigação avaliou a prótese autocentrável Amplatzer. na oclusão desses defeitos, sob a hipótese da eficácia e segurança desta nova concepção instrumental. Para tanto, averiguamos: o porcentual de sucesso técnico, a presença e quantificação do fluxo residual imediato e sua evolução e o impacto do tratamento nas dimensões do ventrículo direito. A casuística foi de 49 pacientes, com a idade variando de 3,4 a 56,2 anos (mediana de 13,3 anos) e 59,2% eram do sexo feminino. O ritmo sinusal esteve presente em 96% dos casos e 85,7% destes evidenciaram índice cardiotorácico > 0,50. O defeito apresentou-se como orifício único em 91,8% dos casos. A borda ântero-superior era deficiente em 40,6% e as médias dos diâmetros longitudinal e transverso corresponderam a 14,3 mm (DP = 5,0 mm) e 14,4 mm (DP = 4,9 mm). A relação fluxo pulmonar / fluxo sistêmico oscilou entre 1,2 a 3,5 [média 2,0 (DP = 1,4)]. A média dos diâmetros estirados foi de 19,3 mm (DP = 5,1 mm) e o das próteses empregadas de 20,3 mm (DP = 4,9 mm). Houve sucesso técnico em 97,9%. A média dos tempos do procedimento foi de 73,8 min (DP = 30,9 min). A única complicação imediata foi taquicardia supraventricular paroxística em 6,1% dos casos. Observou-se fluxo residual imediato em 54,1% dos casos, (45,8% mínimos ou pequenos e 8,3% moderados) caindo para 25% após 24 horas (p = 0,0002). Neste mesmo período houve também diminuição dos pacientes com índice cardiotorácico > 0,50 de 85,7% para 68,4% (p = 0,016). Ao final de 13,1 meses (DP = 1,3 meses) a incidência do fluxo residual reduziu-se para 14,6%, sendo apenas 4,1% moderados. Houve redução significante do diâmetro diastólico do ventrículo direito nas diversas fases do seguimento clínico (p < 0,001). Conclusões: o porcentual de sucesso técnico com o dispositivo Amplatzer® foi alto (97,9%); a incidência de fluxo residual tardio foi de 14,6%; houve redução progressiva e importante do índice cardiotorácico > 0,50 em conseqüência da diminuição significante e progressiva das dimensões do ventrículo direito, o qual atingiu normalização entre o 3º e o 12º meses. As evidências foram de que o dispositivo Amplatzer® permaneceu estável e incorporado ao septo interatrial ao final da observação constituindo-se numa opção segura e eficaz para o tratamento de casos selecionados / Percutaneous closure of the secundum atrial septal defect has been employed as an alternative to surgical treatment. The present investigation evaluated the safety and efficacy of the Amplatzer. prosthesis in the treatment of such defects. For that, we assessed the presence and magnitude of immediate and follow-up residual shunting, the rate of technical success and its impact on the right ventricle. Forty-nine patients with a maximal defect diameter of ¡Ü 30 mm and left-to-right shunting were studied. Age varied from 3.4 to 56.2 years (median of 13.3 years) and 59% were female. Sinus rhythm was present in 96% of cases and 85.7% had a cardiothoracic index of > 0.50. There was a single defect in 91.8% of cases. The anterosuperior rim was deficient in 40.6% and the mean longitudinal and transverse diameters were 14.3 mm (SD = 5.0 mm) and 14.4 mm (SD = 4.9 mm), respectively. The pulmonary to systemic flow ratio varied from 1.2 to 3.5 [mean of 2.0 (SD = 1.4)]. The mean stretched and device diameters were 19.3 mm (SD 5.1 mm) and 20.3 mm (SD = 4.9 mm), respectively. Technical success was achieved in 97.9%. The mean procedure time was 73.8 minutes (SD = 30.9 min). Supraventricular tachycardia was the only complication in 6.1% of cases. Immediate residual shunt was observed in 54.1% of cases (trivial to mild in 45.8% and moderate in 8.3%) falling to 25% after 24 hours (p = 0.0002). At this time, there was also a decrease in the percentage of patients with a cardiothoracic index > 0.50 from 85.7% to 68.4% (p = 0,016). After 13.1 months (SD = 1.3 months) the incidence of residual shunting decreased to 14.6%, being moderate in only 4.1%. There was a significant reduction in the end-diastolic diameter of the right ventricle during follow-up (p < 0,001). Conclusions: the rate of technical success with the Amplatzer® device was high (97.9%); the rate of late residual shunting was 14.6%; there was a progressive and important reduction in the cardiothoracic index > 0.50 as a consequence of the significant and progressive reduction in the dimensions of the right ventricle, which reached normal values between the 3rd and 12th month. At the end of the study, the Amplatzer® device remained stable within the interatrial septum and was incorporated to it, being considered as a safe and effective option in the treatment of selected cases.
|
Page generated in 0.0715 seconds