• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Approches analytique et expérimentale de la convection naturelle en canal vertical : Application aux double-façades photovoltaïques / Analytical and experimental approaches of natural convection in vertical channel : Application to double-façade photovoltaic

Li, Yiqin 06 January 2016 (has links)
Dans le contexte énergétique actuel, le développement de l'énergie solaire passe par son développement à grande échelle en milieu urbain. Les solutions actives et intégrées telles que les double-façades photovoltaïques permettent d'une part d'envisager une valorisation de la chaleur et d'autre part de valoriser l'enveloppe des bâtiments en tant que surface de captation. De plus, cette configuration limite la perte de rendement et l'accélération du vieillissement liées à la surchauffe des cellules. En effet, les composants photovoltaïques sont séparés du bâtiment par une lame d'air et la convection naturelle développée dans cet espace favorise l'évacuation de la chaleur absorbée par les panneaux. Cependant, le comportement global d'une double-façade photovoltaïque est très complexe et encore mal compris. Cette thèse se focalise sur l'expérimentation du phénomène de la convection naturelle. Un banc d'essais, développé dans le cadre de la thèse de Daverat, modélise la double-façade par un canal vertical avec chauffage pariétal. Le fluide d'étude est de l'eau afin de s'affranchir du rayonnement entre parois et d'étudier le couplage conduction-convection. Le banc d'essais est constitué d'un canal vertical de 65cm de haut, chauffé à une densité de flux uniforme, plongé dans une cellule de 1,5m de haut remplie d'eau. L'écoulement est observé par des mesures de densité de flux de chaleur, de température pariétale et de vitesse, ces dernières étant réalisées par vélocimétrie par images de particules et par vélocimétrie laser Doppler. Deux configurations de chauffage sont étudiées : symétrique et asymétrique. Pour l'étude de la configuration avec un chauffage symétrique, les données expérimentales issues du travail de thèse de Daverat sont analysées par une approche zonale. Un découpage du canal est proposé et une analyse des ordres de grandeur permet de comprendre les observations expérimentales. Ainsi, cette analyse se focalise sur le transfert thermique aux parois, l'évolution de la pression dans le canal et sur les fluctuations, en particulier, sur l'évaluation du terme croisé du tenseur de Reynolds. La configuration d'un chauffage asymétrique est étudiée expérimentalement pour la phase de démarrage et le régime stationnaire. Pour la phase de démarrage, la caractérisation des premières heures à partir de la mise en chauffage de la paroi est réalisée en termes de température pariétale, de vitesse et de comportement bi-/tri-dimensionnel de l'écoulement. Un écoulement de retour de grande échelle est mis en évidence. L'impact de la stratification thermique externe du canal est également étudié. Pour le régime stationnaire, les analyses sont réalisées sur des données pour lesquels le régime est considéré établi. Les comportements thermique et dynamique sont étudiés et mettent en évidence deux états distincts. Des écoulements de retour sont également observés. Enfin, les influences du nombre de Prandtl et de l'écartement du canal sont discutées. / Under the current energy context, the development of solar energy goes through its large scale development, especially in urban areas. Active and integrated solutions, such as photovoltaic double-skins, allow both the heat recovery for building needs and the exploitation of building envelope as collecting surface. Furthermore, this configuration limits the efficiency loss and the acceleration of ageing process due to overheating of the solar cells. Indeed, in this configuration, the photovoltaic panels are separated from the building by an air channel and the thermally driven flow that develops in the channel helps to evacuate the heat absorbed by the panels. However, the global behaviour of the photovoltaic double-skin is complex and not yet fully understood. This study is part of a scientific project on multi-scale modelling and experimentation of BIPV components. It focuses on the experimentation of the natural convection phenomenon in double-façades. An experimental apparatus developed during C. Daverat's thesis models the double-façade by a vertical channel with wall heating. The working fluid is water so as to avoid radiative heat transfer between walls. The experimental apparatus consists of a 65 cm high vertical channel, with isoflux heating, immersed in a 1.5 m high water tank. The fluid flow is instrumented with measurements of heat flux, wall temperature and velocity. The velocity measurements are made by Particle Image Velocimetry and Laser Doppler Velocimetry. Two heating configurations are studied: symmetrical (same heat flux is imposed on both walls) and asymmetrical (only one wall is heated, the other one being adiabatic). For the study with symmetrical heating configuration, experimental data from Daverat's thesis are analysed by a zonal approach. The channel is split into several zones and a scaling analysis is conducted in order to explain experimental observations. Thus, the study focuses on heat transfer, pressure evolution in the channel and fluctuations, in particular, the evaluation of the maximum Reynolds stress. The asymmetrical configuration is studied for the transient regime and the steady regime. For the transient regime, early stage (first hours) is characterised in terms of wall temperature, velocity and two- or three-dimensional flow behaviour. A large-scale reversal flow is observed. The impact of external thermal stratification is also studied. For the steady regime, thermal and dynamic behaviours are studied and two different states are distinguished and characterised. Reversal flows are also observed. Finally, the influence of the Prandtl number and the channel width is discussed.
2

Modélisation des écoulements d’air et des transferts de chaleur dans un camion frigorifique : Etude des performances d’un dispositif de rideau d’air innovant pour le maintien de la chaîne du froid et la réduction des pertes à l’ouverture des portes / Modeling of airflow, heat and mass transfers in a refrigerated truck : Study of an innovative air curtain device to protect the cold chain and to reduce energy losses at the door opening

Lafaye de Micheaux, Téo 09 June 2016 (has links)
La préservation de la chaîne du froid est un paramètre particulièrement important dans le cadre de la distribution urbaine, où les fréquentes ouvertures de portes induisent une charge thermique d’infiltration. Afin de réduire les transferts de masse et de chaleur et de protéger l’ouverture, des rideaux d’air ont récemment été installés au niveau de l’ouverture des camions frigorifiques. L’objet de la présente étude est d’étudier ce type confinement. Deux modèles CFD ont été développés pour simuler les champs de températures et de vitesses dans un camion réfrigéré clos. Ils ont permis de montrer que la variation de la vitesse de soufflage ne modifie pas de manière significative la structure des écoulements. Différents conduits d’air sont modélisés. Les résultats numériques montrent que la configuration avec un conduit ouvert améliore fortement le renouvellement d’air. Puis, une étude numérique est réalisée dans le but d’étudier les infiltrations de chaleur et de masse au cours de l’ouverture des portes. Ces écoulements sont bien prédits par le modèle CFD, excepté à la transition entre les deux régimes d’infiltration. Une caisse expérimentale a été équipée d’un dispositif de rideau d’air composé d’un jet ambiant, d’un jet froid ou d’un jet double. En parallèle, un modèle numérique CFD a été développé pour étudier l’influence de différents paramètres. Une bonne concordance entre les résultats numériques et expérimentaux a été observée. L’efficacité du rideau d’air ambiant est maximale lorsque le point d’impact du rideau se situe dans le plan de l’ouverture. Le rideau double maintient efficacement l’homogénéité de la température pour de courtes ouvertures. Le rideau d’air froid est la meilleur configuration, il limite fortement l’augmentation de température de l’enceinte et permet des gains énergétiques importants. / Cold chain safety is a key parameter for urban distribution where the frequent door-opening induces a heat infiltration. In order to reduce heat and mass transfer, air curtain have recently been installed to protect the doorway of refrigerated truck. The aim of this work is to study this type of door insulation. Two CFD numerical models were developed to simulate the temperature and velocity fields in a closed refrigerated truck. These models showed that modifying the blowing velocity does not modify the air flow structure inside the cavity. Different air chutes were modelled. Numerical results demonstrate that the configuration with a convergent and an open duct strongly improves the air renewal. A numerical investigation was performed in order to study heat and mass infiltration rates during the opening. The infiltration flow rate is well predicted by the CFD model, except at the transition between both flow regimes. An experimental truck was equipped with an air curtain setup, composed by an ambient air jet, a cold air jet or a double jet. In parallel, a numerical CFD model was developed to study the influence of various parameters. Experimental and numerical results were found to be in good agreement. The maximum efficiency of the ambient air curtain is reached when the impact point of the jet occurs in the door plane at the ground level. This configuration is only relevant for short opening times. The double air curtain efficiently maintains the temperature homogeneity for short openings. The cold air curtain is the best configuration which strongly limits the temperature increase during the opening and allows important energy savings.
3

On the interactions between urban structures and air flows : A numerical study of the effects of urban morphology on the building wind environment and the related building energy loads / Interactions entre les villes et l'aérodynamique : Etude numérique des effets de la morphologie urbaine sur l'environnement aéraulique urbain et leur impact sur les sollicitations énergétiques des bâtiments

Merlier, Lucie 04 September 2015 (has links)
Cette thèse exploratoire pose les bases scientifiques et méthodologiques d’une approche transversale visant à étudier l’énergétique urbaine et le bio-climatisme. Elle fait appel à des concepts et des outils de l’architecture et l’urbanisme, et à la physique du bâtiment et de la ville. Cette thèse étudie les relations entre la morphologie urbaine et les processus aérodynamiques qui se développent dans la canopée urbaine et leurs effets sur la demande énergétique des bâtiments induite par les infiltrations d’air et les échanges thermiques convectifs. Les spécificités de l’aérodynamique et de la physique urbaines sont d’abord synthétisées et la morphologie de tissus urbains réels est analysée. Une typologie générique de bâtiments isolés et une autre d’îlots urbains en sont déduites. Le modèle CFD est ensuite validé par comparaison des prédictions du modèle avec des résultats expérimentaux et numériques, et des expérimentations numériques sont réalisées sur les différents types morphologiques. Les écoulements moyens sont analysés dans leurs rapports avec la morphologie bâtie, et la distribution des coefficients de pression sur les façades des bâtiments est analysée. Ensuite, les échanges thermiques sont couplés aux processus aérodynamiques. L’amélioration des estimations des échanges convectifs des bâtiments grâce à la CFD est vérifiée par comparaison des résultats de simulation avec des données expérimentales et numériques, ainsi qu’avec les valeurs standard. Une adaptation des fonctions de paroi relatives au transfert thermique est proposée sur la base d’études existantes, et la distribution des échanges convectifs sur les façades de bâtiments est analysée. Enfin, la demande énergétique des bâtiments due aux infiltrations d’air et à la transmission de chaleur au travers de leur envelope est estimée pour différents types morphologiques, et comparée avec les valeurs estimées suivant une approche réglementaire. Les résultats de cette thèse mettent en évidence les effets des propriétés topologiques et métriques des bâtiments et ensembles bâtis sur le développement de recirculations d’air dans la canopée urbaine. Celles-ci induisent une distribution et intensité hétérogènes des coefficients de pression et d’échange convectif sur les façades des bâtiments, qui influent sur le comportement thermique des bâtiments non isolés et perméables à l’air. Par ailleurs, l’estimation de leur demande énergétique diffère suivant si celle-ci est basée sur les valeurs simulées ou standard des coefficients de pression et d’échange convectif. Cependant, l’influence relative de la structure bâtie sur la demande énergétique des bâtiments apparaît plus importante pour les bâtiments isolés thermiquement. La différence entre la demande énergétique par unité de surface de plancher, due aux infiltrations d’air et pertes thermiques au travers de l’enveloppe peut varier de 18% à 47% suivant si le bâtiment est isolé ou situé dans un environnement bâti. / This thesis is an exploratory study that lays the scientific and methodological foundations of a transverse approach for studying urban energy and bio-climatic issues. This approach involves concepts and tools of building and urban physics as well as urban planning and architecture. It addresses the relations between urban morphology and aerodynamic processes, and studies their effects on the building energy loads due to infiltration and convective heat losses. This thesis is divided into three main parts. The first part synthesizes the specificities of urban aerodynamics and urban physics, and analyzes existing urban fabrics from a morphological point of view. Generic typologies of isolated buildings and urban blocks for small scale aerodynamic studies are deduced. The second part validates the computational fluid dynamics (CFD) model (steady RANS RSM) against detailed experimental and numerical data, and presents the numerical experiments performed on the different morphological types. Mean flow structures that develop according to the construction shape and built environment, as well as pressure distribution on the building outer walls are examined. The last part couples heat and air fluxes to evaluate the contribution of urban air flows on the building energy loads. The improvement brought by CFD to the assessment of building convective heat transfers is verified by comparing numerical results to experimental data, detailed numerical studies and standard correlations. An enhanced temperature wall-function adapted for forced convection problems is adjusted to the model based on existing studies, and the convective heat transfers distribution on building facades is analyzed. Finally, the building energy loads due to air infiltration and heat transmission are estimated for typical constructions and compared to standard values. The results of this thesis show strong effects of the topology and dimensionality of constructions and urban structures on the development of recirculation phenomena within the urban canopy layer. The related aerodynamic conditions yield heterogeneous pressure and convective heat transfer intensities and distributions on building facades, which depend upon the considered built morphology. Their effects on building energy loads are logically particularly important in absolute value for buildings that are neither insulated nor air tight. Nonetheless, the estimates of the building energy needs based on standard or simulated pressure and convective heat transfer coefficients often show substantial deviation. Focusing on the relative contribution of the built structure, the effects of the aerodynamic context appear more influential for insulated buildings. Essentially, switching from an exposed to a sheltered building may decrease the energy needs per surface unit of floor due to air infiltration and heat transmission through outer walls by 18% up to 47% according to simulation.

Page generated in 0.0862 seconds