• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase / Experimental study and modeling of health goods packaging using phase change materials

Pech, Thibault 22 April 2016 (has links)
Les emballages thermiques, fabriqués à partir de matériaux isolants et associés à des matériaux à changement de phase, constituent une solution à la problématique de la conservation de produits thermosensibles tout au long de la chaîne de distribution. Cependant, l'optimisation des configurations représente un défi, compte tenu du nombre de paramètres en jeu, et la voie expérimentale demeure coûteuse en temps et en ressources. C'est pourquoi un modèle numérique simplifié a été développé dans le cadre de cette thèse. La thèse comporte un volet expérimental sur la détermination de la perméabilité des emballages ainsi que l'observation de la répartition des températures au sein d'un modèle d'emballage, et un volet numérique. Le volet expérimental a permis de déterminer les coefficients de perméabilité de deux types d'emballages pour différentes configurations, montrant des différences notables selon le modèle de caisse considéré. Les fuites d'air sont principalement dues à l'ouverture de la porte, d'où l'importance du type de joint utilisé et du système de fermeture. Le corps de la caisse, de par sa méthode de manufacture, présente lui aussi des fuites, rendant impossible l'éventualité d'une caisse totalement imperméable. L'observation des températures au sein d'un emballage met en évidence une certaine stratification des températures intérieures, pouvant être diminuée par la présence d'un volume d'air suffisamment important pour permettre des mouvements de convection. Un test avec simulation d'ensoleillement a permis d'observer l'impact important du flux solaire sur le comportement thermique de la caisse, tout en mettant en évidence l'efficacité des matériaux à changement de phase pour l'absorption des variations de température. Le modèle développé est basé sur une méthode nodale. Le programme a été construit de manière à pouvoir simuler un grand nombre de configuration en faisant varier l'agencement des éléments et leur nature. La simulation d'un certain nombre de ces configurations a permis de déterminer la sensibilité du système à divers paramètres. Ainsi il a été montré que la nature du chargement (caractérisée par les valeurs de conductivité, densité et capacité thermique) constitue un paramètre influent sur le système, et donc la connaissance des produits transportés s'avère indispensable à la définition d'une configuration optimale. De la même manière, la nature des matériaux à changement de phase, et en particulier la température de fusion, a une importance notable sur le comportement du système. En revanche, la température d'introduction des MCP a peu d'influence, du moment que le matériau est introduit dans la bonne phase correspondant à son application. La perméabilité de l'emballage quant à elle montre peu d'incidence sur les résultats à long terme, mais des effets de sursaut de température ponctuels dus à des variations brusques de pression extérieure peuvent être observés localement. / Thermal packaging made from insulating materials and associated with phase change materials are a solution to the problem of preservation of temperature sensitive products throughout the distribution chain. However, optimizing configurations is challenging, given the number of parameters involved, and experimentally remains costly in time and resources. This is why a simplified numerical model was developed as part of this thesis. The thesis includes an experimental part on determining the permeability of packaging as well as observation of the temperature distribution within a packaging model, and a digital component. The experimental component made it possible to determine permeability coefficients of two types of packaging for different configurations, showing significant differences in the packaging considered. Air leaks are primarily due to the opening of the door, hence the importance of the type of seal used and the closure system. The body of the box, due to its manufacturing method, presents leaks, making impossible the possibility of a completely impermeable case. The observation of the temperatures within a package highlights some stratification of internal temperatures, which can be reduced by the presence of a sufficiently large volume of air to allow convection movements. A test with sunlight simulation allowed to observe the impact of the solar flux on the thermal behavior of the fund, while highlighting the effectiveness of phase change materials to absorb temperature changes. The developed model is based on a nodal method, associating with each node a wall thickness, which are solved for the associated heat balance equations. Treatment of the phase change is by a method called "equivalent heat capacity". The program was constructed to be able to simulate a large number of configuration by varying the arrangement of the elements and their nature. Simulating a number of these configurations enabled to determine the sensitivity of the system to various parameters. Thus it has been shown that the nature of the load (characterized by the values ​​of conductivity, density and thermal capacity) is a parameter influencing the system, and therefore knowledge of the transported products is essential to the definition of an optimal configuration . Similarly, the nature of phase change materials, and in particular the melting temperature, has a significant importance on the system behavior. In contrast, the PCM introduction temperature has little influence as long as the material is fed in the proper phase corresponding to its application. The permeability of the packaging shows little impact on long-term results, but occasional startle temperature effects due to the rapid changes in external pressure can be observed locally.
2

Modélisation des écoulements d’air et des transferts de chaleur dans un camion frigorifique : Etude des performances d’un dispositif de rideau d’air innovant pour le maintien de la chaîne du froid et la réduction des pertes à l’ouverture des portes / Modeling of airflow, heat and mass transfers in a refrigerated truck : Study of an innovative air curtain device to protect the cold chain and to reduce energy losses at the door opening

Lafaye de Micheaux, Téo 09 June 2016 (has links)
La préservation de la chaîne du froid est un paramètre particulièrement important dans le cadre de la distribution urbaine, où les fréquentes ouvertures de portes induisent une charge thermique d’infiltration. Afin de réduire les transferts de masse et de chaleur et de protéger l’ouverture, des rideaux d’air ont récemment été installés au niveau de l’ouverture des camions frigorifiques. L’objet de la présente étude est d’étudier ce type confinement. Deux modèles CFD ont été développés pour simuler les champs de températures et de vitesses dans un camion réfrigéré clos. Ils ont permis de montrer que la variation de la vitesse de soufflage ne modifie pas de manière significative la structure des écoulements. Différents conduits d’air sont modélisés. Les résultats numériques montrent que la configuration avec un conduit ouvert améliore fortement le renouvellement d’air. Puis, une étude numérique est réalisée dans le but d’étudier les infiltrations de chaleur et de masse au cours de l’ouverture des portes. Ces écoulements sont bien prédits par le modèle CFD, excepté à la transition entre les deux régimes d’infiltration. Une caisse expérimentale a été équipée d’un dispositif de rideau d’air composé d’un jet ambiant, d’un jet froid ou d’un jet double. En parallèle, un modèle numérique CFD a été développé pour étudier l’influence de différents paramètres. Une bonne concordance entre les résultats numériques et expérimentaux a été observée. L’efficacité du rideau d’air ambiant est maximale lorsque le point d’impact du rideau se situe dans le plan de l’ouverture. Le rideau double maintient efficacement l’homogénéité de la température pour de courtes ouvertures. Le rideau d’air froid est la meilleur configuration, il limite fortement l’augmentation de température de l’enceinte et permet des gains énergétiques importants. / Cold chain safety is a key parameter for urban distribution where the frequent door-opening induces a heat infiltration. In order to reduce heat and mass transfer, air curtain have recently been installed to protect the doorway of refrigerated truck. The aim of this work is to study this type of door insulation. Two CFD numerical models were developed to simulate the temperature and velocity fields in a closed refrigerated truck. These models showed that modifying the blowing velocity does not modify the air flow structure inside the cavity. Different air chutes were modelled. Numerical results demonstrate that the configuration with a convergent and an open duct strongly improves the air renewal. A numerical investigation was performed in order to study heat and mass infiltration rates during the opening. The infiltration flow rate is well predicted by the CFD model, except at the transition between both flow regimes. An experimental truck was equipped with an air curtain setup, composed by an ambient air jet, a cold air jet or a double jet. In parallel, a numerical CFD model was developed to study the influence of various parameters. Experimental and numerical results were found to be in good agreement. The maximum efficiency of the ambient air curtain is reached when the impact point of the jet occurs in the door plane at the ground level. This configuration is only relevant for short opening times. The double air curtain efficiently maintains the temperature homogeneity for short openings. The cold air curtain is the best configuration which strongly limits the temperature increase during the opening and allows important energy savings.

Page generated in 0.0817 seconds