Spelling suggestions: "subject:"edifícios, estruturas, etc."" "subject:"edifíciosl, estruturas, etc.""
1 |
Resposta dinâmica de edificações adjacentes acopladas : considerações sobre a interação solo – estrutura / Dynamic response of coupled adjacent buildings : considerations on soil – structure interactionPérez Peña, Luis Alejandro 10 February 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2017-04-13T13:06:10Z
No. of bitstreams: 1
2017_LuisAlejandroPérezPeña.pdf: 15303544 bytes, checksum: 5bf0c81c22e4dd29e8d6f4ab1caf9491 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2017-04-25T15:48:38Z (GMT) No. of bitstreams: 1
2017_LuisAlejandroPérezPeña.pdf: 15303544 bytes, checksum: 5bf0c81c22e4dd29e8d6f4ab1caf9491 (MD5) / Made available in DSpace on 2017-04-25T15:48:38Z (GMT). No. of bitstreams: 1
2017_LuisAlejandroPérezPeña.pdf: 15303544 bytes, checksum: 5bf0c81c22e4dd29e8d6f4ab1caf9491 (MD5) / Nos últimos anos tem sido implementada uma técnica de controle de vibrações chamada de acoplamento estrutural. Essa técnica consiste em ligar duas edificações vizinhas por meio de um dispositivo de acoplamento, com o objetivo de diminuir os efeitos dinâmicos em função das propriedades mecânicas de cada estrutura. Ao fazê-lo, em princípio, é possível controlar a resposta de ambas as estruturas simultaneamente, o que é precisamente a atratividade da técnica. Muitos pesquisadores examinaram a eficácia de vários dispositivos de controle sísmicos para a interconexão de dois edifícios adjacentes considerando que as estruturas estão apoiadas sobre uma base fixa. Porém, toda estrutura, em geral, interage com o solo circundante o qual modifica substancialmente a resposta dessa estrutura. Este processo é conhecido como a interação solo – estrutura (ISE) e os efeitos dessa interação na técnica de acoplamento estrutural são incipientes. Assim, este trabalho tem como objetivo estudar numericamente a influência da interação solo-estrutura no desempenho da técnica do acoplamento para o controle das respostas dinâmicas de duas edificações adjacentes, representadas por meio de pórticos planos, e avaliar a possibilidade de trabalhar com modelos que não considerem essa interação. Os resultados encontrados no presente trabalho evidenciam a importância da consideração dos efeitos de ISE na análise dinâmica de estruturas acopladas. Do mesmo modo, os resultados encontrados mostraram que as análises envolvendo a interação solo – estrutura são de alto grau de complexidade devido a ser a representação mais precisa do problema, razão pela qual a sua consideração ou não depende do grau de precisão que se desejem os resultados. Todas as análises foram realizadas com o programa MATLAB (MathWorks, R2009b). / In recent years, a vibration control technique, called structural coupling, has been studied. This technique consists on linking two neighboring buildings, through a coupling device, with the purpose of reducing dynamic response. It is possible to control both structures response simultaneously, which is precisely the attractiveness of the technique. Several researchers explored the effectiveness of various seismic control devices, in connecting two adjacent buildings, considering they are supported on a fixed base. However, in general, all structures interacts with the surrounding soil, what substantially affects the dynamic response, it is called soil-structure interaction (SSI). Considering SSI on structural coupling is still incipient in literature. Thus, the aim of this research is to study the coupling technique for the control of vibrations of neighboring buildings considering the soil - structure interaction to understand the complete phenomenon and to evaluate the possibility of working with simplified numerical models that do not consider this interaction. The results found show that SSI effects cannot be neglected on dynamic analysis of coupled structures. Furthermore, the results showed that the analyzes involving soil - structure interaction are highly complex due to be the most accurate representation of the problem, reason why its consideration or not depends on the degree of precision that the results are desired. All analyzes were performed with the MATLAB program (MathWorks, R2009b).
|
2 |
Eficiência energética em edificações públicas do Poder Executivo Federal : oportunidades e desafios no contexto do Programa Brasileiro de Etiquetagem (PBE – Edifica)Gomes, Anderson Ferreira 24 July 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2017. / Submitted by Priscilla Sousa (priscillasousa@bce.unb.br) on 2017-10-17T11:39:08Z
No. of bitstreams: 1
2017_AndersonFerreiraGomes.pdf: 3647211 bytes, checksum: de80241705c6b2aaa0c415170dd97972 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-11-07T15:27:23Z (GMT) No. of bitstreams: 1
2017_AndersonFerreiraGomes.pdf: 3647211 bytes, checksum: de80241705c6b2aaa0c415170dd97972 (MD5) / Made available in DSpace on 2017-11-07T15:27:23Z (GMT). No. of bitstreams: 1
2017_AndersonFerreiraGomes.pdf: 3647211 bytes, checksum: de80241705c6b2aaa0c415170dd97972 (MD5)
Previous issue date: 2017-11-07 / No contexto mundial, a eficiência energética em edifícios tem produzido mudanças significativas no processo de projeto, construção e gestão das edificações. Neste sentido, o Governo Federal brasileiro instituiu compulsoriedade às licitações com foco na Etiquetagem de Eficiência Energética de suas edificações na classificação máxima, Nível “A” do Programa Brasileiro de Etiquetagem (PBE-Edifica), (BRASIL, 2014). O presente trabalho tem como objetivo estabelecer um panorama nacional quantitativo e qualitativo das edificações públicas federais com foco na Etiquetagem de Eficiência Energética, visando identificar oportunidades e desafios neste processo. O método do trabalho inclui uma primeira etapa de pesquisas nas bases de dados do Governo Federal (Comprasnet e SPIUnet), envolvendo a investigação do panorama de Licitações Públicas Sustentáveis e o mapeamento do universo de edificações de propriedade da União. São também investigados atores importantes do processo, com entrevistas presenciais e questionários realizados online. Na segunda etapa realizou-se um estudo de caso em edifício da Advocacia Geral da União (AGU), para aprofundar alguns aspectos relativos ao processo de contratação de projetos e obras através de licitações. Os resultados identificam, primeiramente, que o universo de imóveis com tipologia-destinação e área construída abrangido efetivamente pela Instrução Normativa 02 (não residenciais) é de 5.503 edificações com área total de 218.980.875,00 m2, distribuídos nacionalmente em 923 municípios. O total de compras públicas entre 2010 e 2014 foi de 318,2 bilhões de reais, constatando-se, devido ao alto valor, que ainda há possibilidade de Uso do Poder de Compra. Com a identificação e localização do universo de edificações abrangidas de fato pela IN 02, o Governo Federal poderá estabelecer um plano de metas, acompanhando e gerindo a evolução por unidade da federação quanto à Etiquetagem das mesmas. A IN 02 busca aumentar as licitações sustentáveis segundo o critério de eficiência energética, apresentando-se de suma importância frente ao universo de edificações públicas e ao panorama atual das licitações. Identificou-se também como importante a continuidade dos trabalhos do Grupo Técnico Operacional da IN 02. Quanto ao estudo de caso o desafio está na criação de códigos de material sustentáveis no seu sistema de almoxarifado criando editais padrão, realizando licitações de registro de preços. Dentre os desafios e barreiras podem-se citar: a evolução do Catálogo de Material (CATMAT) com a inclusão de todos os itens de material etiquetados com nível “A” da tabela de produtos aprovados no PBE; a adequação do Catálogo de Serviços (CATSER) com a inclusão de itens de serviço de etiquetagem de eficiência energética de edificações do PBE-Edifica. Cabe aos órgãos do SISG assimilarem esta nova demanda, ajustando o cotidiano de seus processos de licitação e contratação para a consecução da ENCE “A” do PBE na esfera do Poder Executivo Federal. / In the world context, energy efficiency in buildings has produced significant changes in the design, construction and management of buildings. In this sense, the Brazilian Federal Government instituted compulsory bidding with a focus on Energy Efficiency Labeling of its buildings in the maximum classification, Level "A" of the Brazilian Program of Labeling (PBEEdifica), (BRAZIL, 2014). The present work aims to establish a national quantitative and qualitative panorama of federal public buildings with a focus on Energy Efficiency Labeling, aiming at identifying opportunities and challenges in this process. The work method includes an initial stage of research in the Federal Government databases (Comprasnet and SPIUnet), involving the investigation of the panorama of Sustainable Public Tenders and the mapping of the universe of buildings owned by the Union. Process, with face-to-face interviews and online questionnaires. In the second stage, a case study was carried out in a building of the Federal Attorney General's Office (AGU), in order to deepen some aspects related to the contracting process of projects and works through bids. The results identify, firstly, that the universe of real estate with typology-destination and built area effectively covered by Normative Instruction 02 (non-residential) is 5,503 buildings with a total area of 218,980,875.00 m2, distributed nationally in 923 municipalities. The total of public purchases between 2010 and 2014 was 318.2 billion Reais, evidencing, due to the high value, that there is still possibility of Use of Purchasing Power. With the identification and location of the universe of buildings actually covered by IN 02, the Federal Government will be able to establish a goal plan, monitoring and managing the evolution by unit of the federation as to their labeling. IN 02 seeks to increase sustainable bidding according to the criterion of energy efficiency, being of paramount importance in relation to the universe of public buildings and the current panorama of the bids. It was also identified as important the continuity of the IN 02 Operational Technical Group's work. Regarding the case study, the challenge is to create sustainable material codes in its warehouse system by creating standard edicts, conducting price registration bids. Among the challenges and barriers can be mentioned: the evolution of the Material Catalog (CATMAT) with the inclusion of all material items labeled "A" in the list of products approved in the PBE; The adequacy of the Service Catalog (CATSER) with the inclusion of energy efficiency labeling service items from PBEEdifica buildings. It is up to the SISG bodies to assimilate this new demand, adjusting the dayto- day of their bidding and contracting processes for the achievement of ENCE "A" of the PBE in the sphere of the Federal Executive Branch.
|
3 |
Manifestações patológicas em edifícios do Programa de Arrendamento Residencial (PAR) em Belo Horizonte, MG, executados em alvenaria estrutural / Pathological manifestations in buildings of the Program of Residential Leasing (PAR) in Belo Horizonte, MG, executed in structural masonryAlvarenga, Maria Cláudia Sousa 23 June 2010 (has links)
Made available in DSpace on 2015-03-26T13:28:35Z (GMT). No. of bitstreams: 1
resumo.pdf: 34712 bytes, checksum: c196e12310704414ba4f06e741ad13a4 (MD5)
Previous issue date: 2010-06-23 / The present work consists of the evaluation of constructive performance of some enterprises contained in the "Programa de Arrendamento Residencial (PAR) from Caixa Econômica Federal in Belo Horizonte, Minas Gerais/Brazil, executed with the structural masonry technology. The proposal of this research was the analysis of the existent pathological manifestations, with emphasis in the structural aspect of the enterprises, however, also contemplating other types of damages in the constructions. There were chosen five enterprises being taken into account the following parameters: age, load and location. The data were taken accomplished through inspections. Firstly it was made a qualitative analysis in the five enterprises through a meticulous evaluation of the pathological manifestations, demonstrated through the pictures took "in loco ", only two of these enterprises were inhabited and they could be analyzed internally. This interns analysis provided a meticulous quantification of the pathological manifestations found in the apartments and circulation in all the floors. After that, the types more frequent of pathological manifestations were verified in constructions of structural masonry in the loads and ages analyzed. The responsible administrator for the enterprises available the projects and some responsible builders accepted to answer referring questions about the projects and the executions of the works. Like this, it was possible to cross project information and execution of the work, diagnosing the origin of each type of found pathological manifestation. With the cause of the problems, collective and preventive solutions were proposed and, looking for the improvement of the quality of the enterprises already built and future enterprises, pointing out that the collective solutions a usually have a some difficulty to be executed. It was compared the quantitative results of the enterprises in different ages and loads and it was observed that, as expected, the age interferes in the number of occurrences of pathological manifestations, however project mistakes and execution makes that useful life of the work is reduced through the increase and the precocious emergence of pathologies in the constructions. / O presente trabalho consiste na avaliação de desempenho construtivo de empreendimentos contidos no Programa de Arrendamento Residencial (PAR) da Caixa Econômica Federal, na Cidade de Belo Horizonte, executados com a tecnologia de alvenaria estrutural. A proposta desta pesquisa foi a análise das manifestações patológicas existentes, com ênfase no aspecto estrutural dos empreendimentos, porém, contemplando também outros tipos de danos nas edificações. Foram escolhidos cinco empreendimentos, levando-se em conta os seguintes parâmetros: idade, porte e localização. O levantamento de dados foi realizado por meio de vistorias, de avaliação dos projetos disponibilizados e de entrevistas com representantes das construtoras a respeito dos projetos e das execuções das obras. Primeiramente, foi realizada uma análise qualitativa dos cinco empreendimentos por meio de uma avaliação minuciosa das manifestações patológicas. A partir desta avaliação, as manifestações patológicas encontradas nos apartamentos e na área de circulação foram quantificadas, sendo verificados os tipos mais frequentes nas edificações analisadas. Assim, foi possível confrontar informações de projeto e execução da obra, diagnosticando a origem de cada tipo de manifestação patológica encontrada. Com base nesta análise, foram propostas soluções corretivas e preventivas, visando à melhoria da qualidade dos empreendimentos já edificados e de empreendimentos futuros. Deve-se ressaltar que as soluções corretivas muitas vezes têm um elevado grau de dificuldade para serem executadas. Compararam-se os resultados quantitativos dos empreendimentos de idades e portes diferentes e observou-se que, como esperado, a idade interfere no número de ocorrências de manifestações patológicas. No entanto, erros de projeto e execução fazem com que a vida útil da obra seja reduzida, tendo em vista o aparecimento precoce de patologias nas edificações.
|
4 |
Análise da influência do sombreamento causado pelos edifícios na zona central de CuritibaCampos, Giovana de Almeida Coelho 02 December 2014 (has links)
O crescimento urbano e o ritmo acelerado na concentração de pessoas nas cidades são inevitáveis. A verticalização das construções como solução para atender a necessidade da máxima ocupação do solo e para justificar a infraestrutura investida pelo poder público nas áreas centrais, causa consideráveis impactos no entorno em que estão inseridas. Contudo, a urbanização em si não é um problema, e sim a forma como as cidades estão sendo construídas e ocupadas. Diante disso, o trabalho apresenta como objetivo principal a verificação da influência do sombreamento gerado pelos edifícios altos dentro de um recorte definido na zona com maior capacidade de verticalização em Curitiba. Esta pesquisa foi desenvolvida em quatro etapas: a primeira, de fundamentação teórica com o estudo da literatura existente sobre o tema, a segunda para definição da região de estudo na cidade e os períodos a serem analisados, a terceira etapa para delimitação do recorte de estudo com análises de cada período e, a quarta com a elaboração das simulações computacionais nos softwares Auto CAD, Sketchup Pro, Excel e Ecotect para obtenção de resultados. Durante a evolução da pesquisa, verificou-se que, de fato, o nsombreamento causado pelos edifícios altos comprometem consideravelmente as construções vizinhas a eles e todo o seu entorno imediato. Além disso, foi concluído que Curitiba, uma cidade considerada fria, sofre nos períodos de inverno com o excessivo sombreamento nas áreas públicas entre quadras. Em contrapartida, as áreas abertas de lazer estão posicionadas adequadamente e não se prejudicam com a verticalização da Zona Central. De qualquer forma, a intenção de redução de impacto gerado por esses processos deve ser planejada em um contexto mais significativo. A elaboração de projetos deve ter como premissa a adequação ao clima e ao contexto local, da mesma forma que devem ser analisados os impactos ambientais dessas sobre as construções vizinhas e os espaços externos localizados em uma área de influência. A idéia de preservar o skyline já consolidado na cidade, evitando edifícios muito altos, pode ser uma alternativa para minimização dos impactos de sombreamento. / Urban growth and the fast pace in the concentration of people in cities are inevitable. Building verticalization as a solution to attend the need of maximum land use and to justify the infrastructure invested by the government in central areas, cause considerable impacts on the environment which they are. However, urbanization is not a problem itself, but how cities are being built and occupied. Thus, the main goal of this work is to verify the shadow influence caused by tall buildings in a specific area inside of the zone with more capacity of verticalization in Curitiba. This research was developed in four steps: the first one was to study the existing literature about this topic, second to define study section in the city and periods to be analyzed, third step to delimit a zoom of study with analysis about all periods and, fourth with computer simulations on Auto CAD, Sketchup Pro, Excel and Ecotect softwares to obtain important results. During the evolution of this work, it was verified that the shading caused by tall buildings undertake considerably neighboring buildings and all surrounding area. Furthermore, it was concluded that Curitiba, a cold city, suffers in winter season due to excessive shading in public spaces between blocks. On the other hand, open spaces as squares are correctly positioned and do not harm with verticalization on the downtown zone. Anyway, the intention to reduce the impact caused by these processes must be planned in a more embracing context. Project elaboration must consider local climate and urban context, just as the environmental impacts of those on neighboring buildings and on open spaces. The idea of preserving skylines already consolidate, avoiding tall buildings, can be an alternative to minimize shading impacts.
|
Page generated in 0.0872 seconds