Spelling suggestions: "subject:"elementos dde proteção solar"" "subject:"elementos dde proteção polar""
1 |
Análise da eficiência de elementos de proteção solar em relação ao sombreamento e a iluminação natural estudo de caso: salas de aula do campus I da UFPBMarques, Matheus Peixoto de Paula 29 March 2012 (has links)
Made available in DSpace on 2015-05-14T12:09:17Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 11721835 bytes, checksum: d91df33daa9451f253a6f22c8d5b1f6b (MD5)
Previous issue date: 2012-03-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work addresses topics such as shading devices, shading and daylighting. It
aims at verifying the efficiency of shading devices found classroom buildings at
UFPB's campus I, with respect to shading and daylighting. The results of the
research focus in the diagnosis of the solutions in the case study, by using three
dimensional models (3D) and computer simulation. The digital models were
constructed from data collected in field surveys. The computer programs used were
the Solar Tool, Ecotect and Daysim. In parallel, we investigated a set of hypothetical
situations, considering all the solutions found in the survey, in order to identify the
performance of the solutions in other orientation facade. The evaluation of the
models was made from performance measures such as the percentage of shading,
percentage of sky visibility and useful daylight illuminances (UDI). From the results,
we observed that: a) south-oriented façades with unprotected openings allow for
environments with higher levels and better distribution of natural lighting; b) a large
part of the orientation facade analyzed, except in the northwest and east, more than
50% of the samples obtained a good performance of daylighting; c) the percentage of
shading is not enough to say whether an element of sunscreen is effective or not,
which can generate misleading conclusions when used alone; d) the correlation of
the performance of daylighting and performance of shading with the percentage of
sky visibility, showed that for every orientation facade there is an optimal ratio
between the percentage of shading and the percentage of sky visibility, and for the
facade analyzed, the values of these measures are generally around 88.7% of
shading of the opening and 8.1% of sky visibility. / Este trabalho aborda temas como elementos de proteção solar, sombreamento e iluminação natural. Tem como objetivo a verificação da eficiência de proteções solares encontradas em edificações de salas de aula no campus I da UFPB, no que diz respeito ao sombreamento e à iluminação natural. Os resultados da investigação centram-se no diagnóstico das soluções encontradas no estudo de caso, através da utilização de modelos tridimensionais (3D) e simulação computacional. Os modelos digitais foram construídos a partir de dados coletados em levantamento de campo. Os programas computacionais utilizados foram o Solar Tool, Daysim e o Ecotect. Em paralelo, foi investigado um conjunto de situações hipotéticas, considerando todas as soluções encontradas no levantamento, com objetivo de identificar o desempenho das soluções em outras orientações. A avaliação dos modelos foi feita a partir de medidas de desempenho como o percentual de sombreamento, percentual de visibilidade do céu e do useful daylight illuminances (UDI). Com os resultados obtidos foi possível observar que: a) fachadas com aberturas sem proteção orientadas para o Sul geram ambientes com melhores níveis e distribuição da iluminação natural; b) em grande parte das orientações analisadas, exceto na Noroeste e Leste, mais de 50% da amostra obteve um bom desempenho da iluminação natural; c) o percentual de sombreamento não é suficiente para afirmar se um sombreamento é eficaz ou não, podendo gerar conclusões equivocadas quando utilizado isoladamente; d) a correlação da performance da iluminação natural e do desempenho do sombreamento com o percentual de visibilidade do céu, mostrou que para cada orientação existe uma relação ideal do percentual de sombreamento com o percentual de visibilidade do céu, sendo que para as orientações analisadas os valores destas medidas se encontraram, em geral, próximo de 88,7% de sombreamento da abertura e 8,1% de visibilidade do céu.
|
2 |
A Influência do sombreamento e da absortância da envoltória no desempenho térmico e energético de edificações residenciais multipavimentos na cidade de João Pessoa-PB / The influence of shading and absortance of the envelope in the thermal and energy performance of residential buildings in João Pessoa-PBMartins, Lúcia Helena Aires 30 September 2013 (has links)
Made available in DSpace on 2015-05-14T12:09:28Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 11490325 bytes, checksum: c5db739b54c8a079086312556753c528 (MD5)
Previous issue date: 2013-09-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Given the importance of adaptation of the building to the climate in search of more
thermally and energy efficient buildings, this study evaluates the influence of shading devices
and solar absorption coefficient of the envelope in the thermal and energy performance of
residential buildings located in the Manaíra, João Pessoa-PB , through computer simulations,
using the DesignBuilder program. The work involved the development of a methodology for
the identification of the main characteristics of residential buildings in urban cutout study.
Were analyzed 25 buildings with respect to: frequency of occurrence of numbers of floors,
terrain and edification shape, area of apartments, percentage area of window and of wall in
the facades, facade orientation, existence of elements of sun protection and constructive
characteristics general. Based on the data collected, a representative model of constructive
reality was elaborated, called predominant typology and used as the base case in the
simulations. One set of typologies was simulated, determined from alterations constructive
variables such as solar protection and absorption coefficient of the envelope, as well as, the
urban variable surroundings obstruction. The analysis variables considered were the
temperature of the internal air, solar gain through opaque and transparent closings and load
required for cooling. Was observed that the shading caused in the area around contributes to
a reduction in internal temperature and solar gain, but the balance is not always favorable,
some models analyzed presented an increase in solar gain by opaque closings. Just like the
density of surrounding area can elevate the air temperature and energy consumption in
domestic environments. The use of the shutter openings resulted in better thermal and
energy performance, higher than the adoption of low absorption coefficient ( = 0.20). / Diante da importância da adequação da edificação ao clima em busca de edificações
mais eficientes termicamente e energeticamente, este trabalho avalia a influência dos
dispositivos de sombreamento e do coeficiente de absorção solar da envoltória no
desempenho térmico e energético de edifícios residenciais multipavimentos localizados no
bairro de Manaíra, município de João Pessoa-PB, através de simulações computacionais,
utilizando o programa DesignBuilder. O trabalho compreendeu o desenvolvimento de uma
metodologia para o levantamento das principais características de edifícios residenciais
multipavimentos no recorte urbano em estudo. Foram analisados 25 edifícios com relação à:
frequência de ocorrência de números de pavimentos, forma do terreno e da edificação, área
dos apartamentos tipo, percentual de área de janela e de parede nas fachadas, orientação
das fachadas, existência de elementos de proteção solar e características construtivas
gerais. Com base nos dados levantados, um modelo representativo da realidade construtiva
foi elaborado, denominada de tipologia predominante e utilizada como caso base das
simulações. Um conjunto de tipologias foi simulado, determinado a partir de alterações de
variáveis construtivas, como proteção solar e coeficiente de absorção da envoltória, assim
como, a variável urbana obstrução do entorno. As variáveis de análise consideradas foram a
temperatura do ar interna, o ganho solar através dos fechamentos opacos e transparentes e
a carga necessária para resfriamento. Observou-se que o sombreamento provocado pelo
entorno contribui para a redução da temperatura interna e ganho de calor, porém nem
sempre o balanço é favorável, alguns modelos analisados apresentaram um aumento no
ganho solar pelos fechamentos opacos. Assim como, o adensamento do entorno, pode
elevar a temperatura do ar e o consumo de energia nos ambientes internos. O uso da
veneziana nas aberturas resultou no melhor desempenho térmico e energético, superior à
adoção de baixo coeficiente de absorção (=0,20).
|
Page generated in 0.0714 seconds