• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de sistemas híbridos em estabelecimentos assistenciais de saúde (EAS) visando o conforto térmico e redução de consumo energético / Hybrid systems analysis in healthcare establishments aiming the thermal comfort and energy consumption reduction

Ana Marta Aragão Grimm 08 October 2012 (has links)
No contexto de questões ambientais mundiais, os estabelecimentos assistenciais de saúde (EAS), devido a diversas mudanças apresentadas na fisiologia dos edifícios hospitalares nos últimos 100 anos, se inserem como grandes consumidores de energia. Tais alterações devem-se ao avanço das ciências médicas, a novas tecnologias em sistemas e equipamentos e ao crescimento populacional. O presente trabalho pretende analisar a contribuição do uso de tecnologias passivas em Estabelecimentos Assistenciais de Saúde (EAS) no que tange o desempenho térmico e energético, considerando normas específicas para este uso que exigem áreas assépticas através do uso de tecnologias ativas visando o controle da infecção hospitalar e a qualidade do ar interior. Esta configuração caracteriza para estes edifícios, sistemas híbridos com relação a tecnologias ativas e passivas. O caráter experimental da pesquisa foi realizado através de Simulação Computacional com o Software Energy Plus versão 7.0 em que foi analisado o desempenho térmico e energético de um edifício hospitalar. Inicialmente o edifício foi simulado em condições existentes e posteriormente foram realizadas diversas simulações com diferentes soluções arquitetônicas entre elas a inserção de tetoverde. / In the context of global environmental issues the Healthcare Establishments due to several changes on the physiology of hospital buildings over the past one hundred years have fallen as large energy consumers. Such changes were due to the advancement of medical science, new technologies in systems and equipments, and population growth. The present work intends to analyze the contribution of the use of passive technologies in Healthcare Establishments regarding the thermal and energetic performance considering specific standards for this use that demands aseptic areas through the use of active technologies aiming hospital infection control and indoor air quality. This configuration characterizes for these buildings hybrid systems related to active and passive technologies. The research\'s experimental character was made through Computer Simulation with the Software Energy Plus version 7.0 in which were analyzed the thermal and energetic performance of a hospital building. Initially the building was simulated in existing conditions and afterwards several simulations were made with different architectural solutions, in which was among them the insertion of a green roof.
2

Análise de sistemas híbridos em estabelecimentos assistenciais de saúde (EAS) visando o conforto térmico e redução de consumo energético / Hybrid systems analysis in healthcare establishments aiming the thermal comfort and energy consumption reduction

Grimm, Ana Marta Aragão 08 October 2012 (has links)
No contexto de questões ambientais mundiais, os estabelecimentos assistenciais de saúde (EAS), devido a diversas mudanças apresentadas na fisiologia dos edifícios hospitalares nos últimos 100 anos, se inserem como grandes consumidores de energia. Tais alterações devem-se ao avanço das ciências médicas, a novas tecnologias em sistemas e equipamentos e ao crescimento populacional. O presente trabalho pretende analisar a contribuição do uso de tecnologias passivas em Estabelecimentos Assistenciais de Saúde (EAS) no que tange o desempenho térmico e energético, considerando normas específicas para este uso que exigem áreas assépticas através do uso de tecnologias ativas visando o controle da infecção hospitalar e a qualidade do ar interior. Esta configuração caracteriza para estes edifícios, sistemas híbridos com relação a tecnologias ativas e passivas. O caráter experimental da pesquisa foi realizado através de Simulação Computacional com o Software Energy Plus versão 7.0 em que foi analisado o desempenho térmico e energético de um edifício hospitalar. Inicialmente o edifício foi simulado em condições existentes e posteriormente foram realizadas diversas simulações com diferentes soluções arquitetônicas entre elas a inserção de tetoverde. / In the context of global environmental issues the Healthcare Establishments due to several changes on the physiology of hospital buildings over the past one hundred years have fallen as large energy consumers. Such changes were due to the advancement of medical science, new technologies in systems and equipments, and population growth. The present work intends to analyze the contribution of the use of passive technologies in Healthcare Establishments regarding the thermal and energetic performance considering specific standards for this use that demands aseptic areas through the use of active technologies aiming hospital infection control and indoor air quality. This configuration characterizes for these buildings hybrid systems related to active and passive technologies. The research\'s experimental character was made through Computer Simulation with the Software Energy Plus version 7.0 in which were analyzed the thermal and energetic performance of a hospital building. Initially the building was simulated in existing conditions and afterwards several simulations were made with different architectural solutions, in which was among them the insertion of a green roof.
3

A Influência do sombreamento e da absortância da envoltória no desempenho térmico e energético de edificações residenciais multipavimentos na cidade de João Pessoa-PB / The influence of shading and absortance of the envelope in the thermal and energy performance of residential buildings in João Pessoa-PB

Martins, Lúcia Helena Aires 30 September 2013 (has links)
Made available in DSpace on 2015-05-14T12:09:28Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 11490325 bytes, checksum: c5db739b54c8a079086312556753c528 (MD5) Previous issue date: 2013-09-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Given the importance of adaptation of the building to the climate in search of more thermally and energy efficient buildings, this study evaluates the influence of shading devices and solar absorption coefficient of the envelope in the thermal and energy performance of residential buildings located in the Manaíra, João Pessoa-PB , through computer simulations, using the DesignBuilder program. The work involved the development of a methodology for the identification of the main characteristics of residential buildings in urban cutout study. Were analyzed 25 buildings with respect to: frequency of occurrence of numbers of floors, terrain and edification shape, area of apartments, percentage area of window and of wall in the facades, facade orientation, existence of elements of sun protection and constructive characteristics general. Based on the data collected, a representative model of constructive reality was elaborated, called predominant typology and used as the base case in the simulations. One set of typologies was simulated, determined from alterations constructive variables such as solar protection and absorption coefficient of the envelope, as well as, the urban variable surroundings obstruction. The analysis variables considered were the temperature of the internal air, solar gain through opaque and transparent closings and load required for cooling. Was observed that the shading caused in the area around contributes to a reduction in internal temperature and solar gain, but the balance is not always favorable, some models analyzed presented an increase in solar gain by opaque closings. Just like the density of surrounding area can elevate the air temperature and energy consumption in domestic environments. The use of the shutter openings resulted in better thermal and energy performance, higher than the adoption of low absorption coefficient ( = 0.20). / Diante da importância da adequação da edificação ao clima em busca de edificações mais eficientes termicamente e energeticamente, este trabalho avalia a influência dos dispositivos de sombreamento e do coeficiente de absorção solar da envoltória no desempenho térmico e energético de edifícios residenciais multipavimentos localizados no bairro de Manaíra, município de João Pessoa-PB, através de simulações computacionais, utilizando o programa DesignBuilder. O trabalho compreendeu o desenvolvimento de uma metodologia para o levantamento das principais características de edifícios residenciais multipavimentos no recorte urbano em estudo. Foram analisados 25 edifícios com relação à: frequência de ocorrência de números de pavimentos, forma do terreno e da edificação, área dos apartamentos tipo, percentual de área de janela e de parede nas fachadas, orientação das fachadas, existência de elementos de proteção solar e características construtivas gerais. Com base nos dados levantados, um modelo representativo da realidade construtiva foi elaborado, denominada de tipologia predominante e utilizada como caso base das simulações. Um conjunto de tipologias foi simulado, determinado a partir de alterações de variáveis construtivas, como proteção solar e coeficiente de absorção da envoltória, assim como, a variável urbana obstrução do entorno. As variáveis de análise consideradas foram a temperatura do ar interna, o ganho solar através dos fechamentos opacos e transparentes e a carga necessária para resfriamento. Observou-se que o sombreamento provocado pelo entorno contribui para a redução da temperatura interna e ganho de calor, porém nem sempre o balanço é favorável, alguns modelos analisados apresentaram um aumento no ganho solar pelos fechamentos opacos. Assim como, o adensamento do entorno, pode elevar a temperatura do ar e o consumo de energia nos ambientes internos. O uso da veneziana nas aberturas resultou no melhor desempenho térmico e energético, superior à adoção de baixo coeficiente de absorção (=0,20).

Page generated in 0.082 seconds