• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 23
  • 21
  • 21
  • 18
  • 15
  • 14
  • 7
  • 2
  • 2
  • 2
  • Tagged with
  • 427
  • 150
  • 145
  • 122
  • 74
  • 68
  • 54
  • 54
  • 53
  • 53
  • 51
  • 46
  • 44
  • 43
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Impedância bioelétrica na ocorrência da pré-eclâmpsia /

Silva, Elaine Gomes da. January 2012 (has links)
Orientador: José Carlos Peraçoli / Coorientador: Maria Antonieta de Barros Leite Carvalhaes / Banca: Roberto Antonio de Araújo Costa / Banca: Roseli Yamamoto Nomura / Banca: Mary Ângela Parpinelli / Banca: Maria Helena B. Benício / Resumo: Analisar possíveis associações entre resistência e reactância, avaliadas pela análise de impedância bioelétrica (BIA), no primeiro, segundo e terceiro trimestres de gestação, e ocorrência de pré-eclâmpsia; identificar qual o momento mais precoce da associação. Coorte prospectiva. Hospital das Clinicas da Faculdade de Medicina de Botucatu/Unesp. 380 gestantes acompanhadas no Serviço. As gestantes foram submetidas à BIA, no primeiro (até 14 semanas), segundo (15 a 28 semanas) e terceiro (29 a41 semanas) trimestres, para avaliação dos valores de resistência e reactância. Considerou-se o desenvolvimento de hipertensão arterial, após a 20ª semana, com ou sem proteinúria, respectivamente, Pré-eclâmpsia (PE) e Hipertensão Gestacional (HG). Foi realizada a análise estatística através teste T de student e do Odds-Ratio considerando p<0,05. No primeiro trimestre a média da resistência e reactância do grupo PE (508Ω;57Ω) foi significativamente menor que a observada no grupo normotenso (580Ω;66Ω). No segundo trimestre as médias de resistência e reactância no grupo PE, respectivamente, (502Ω e 53Ω), foram menores significativamente do que as encontradas no grupo normotenso (566Ω e 57Ω). No terceiro trimestre foram também significativamente menores quando comparadas com o grupo normotenso (452 Ω e 47 Ω). No primeiro trimestre o Odds ratio (OR) para a resistência foi de 0,99 (IC 0,98 - 1,0) com p=0,002 e reactância foi de 0,93 (IC 0,85- 1,01) com p=0,07. No Segundo trimestre o OR foi de 0,99 (IC 0,98-0,99) e p=0,001 e a reactância o OR foi de 0,95 (IC=0,9-1,00) com p=0,05. No terceiro trimestre o OR foi de foi de 0,99 (IC 0,98-0,99) e p=0,0010 para resistência e de 0,93 (IC 0,88 - 0,98) e p=0,01 para reactância. A bioimpedância mostrou associação através da resistência tanto no primeiro quanto no segundo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To analyze possible associations between resistance and reactance, as evaluated by electrical impedance analysis (BIA) in the first, second and third pregnancy trimesters, and preeclampsia occurrence; to identify the earliest moment of association. Prospective cohort. Botucatu School of Medicine University Hospital/Unesp. Population: 380 pregnant women attended to by the Service. The pregnant women underwent BIA in the first (up to 14 weeks), second (15 to 28 weeks) and third (29 to 41 weeks) trimesters for evaluation of resistance and reactance values. The development of arterial hypertension, after the 20th week, with or without proteinuria, respectively, Preeclampsia (PE) and Gestational Hypertension (GH) was considered. Statistical analysis by Odds-Ratio was performed considering p<0.05. In the first trimester, the resistance and reactance means in the PE group (508Ω;57Ω) were significantly lower than those observed in the healthy group (580Ω;66Ω). In the second trimester, the resistance and reactance means in the PE group, respectively (502Ω and 53Ω), were lower than those found in the healthy group (566Ω and 57Ω). In the third trimester were lower than than those found in the healthy group (452 Ω e 47 Ω). In the first trimester, the Odds ratio (OR) for resistance was 0.99 (CI 0.98 - 1.0) with p=0.002, and reactance was 0.93 (CI 0.85-1.01) with p=0.07. In the second trimester, OR was 0.99 (CI 0.98-0.99) and p=0.001, and for reactance, OR was 0.95 (CI=0.9-1.00) with p=0.05. In the third trimester, the Odds ratio (OR) for resistance was (IC 0,98-0,99) with p=0,0010 and 0,93 (IC 0,88 - 0,98) with p=0,01 for reactance. Bioimpedance showed association by means of resistance both in the first... (Complete abstract click electronic access below) / Doutor
32

Análise através de simulações numéricas TLM da influência do comportamento dispersivo do solo em sistemas de aterramento frente a descargas atmosféricas /

Wisintainer, Bruno William, Almaguer, Hugo Armando Dominguez, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2010 (has links) (PDF)
Orientador: Hugo Armando Domínguez Almaguer. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Elétrica.
33

Otimização da exploração de centrais hídricas utilizando algoritmos genéticos, em ambiente de mercado

Sampaio, Gil Silva January 2012 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores. Área de Especialização de Energia. Faculdade de Engenharia. Universidade do Porto. 2012
34

Reformulação das restrições de complementaridade em problemas de fluxo de potência ótimo /

Alencar, Marina Valença. January 2019 (has links)
Orientador: Edilaine Martins Soler / Banca: Leonardo Nepomuceno / Banca: Guilherme Guimarães Lage / Resumo: Neste trabalho duas abordagens de resolução são propostas para tratar restrições de complementaridade que modelam a atuação de dispositivos de controle de tensão no problema de fluxo de potência ótimo reativo, uma proposta de reformulação das restrições via programação inteira e a outra via desigualdades válidas. Este problema é modelado matematicamente como um problema de programação não linear inteira mista com variáveis discretas e restrições de complementariedade. As restrições de complementaridade na atuação dos dispositivos de controle de tensão (tap dos transformadores em fase e bancos de capacitores e reatores shunt) têm por objetivo viabilizar a implementação das soluções obtidas em sistemas elétricos de grande porte, para que eles operem apenas quando um dos limites de tensão da barra, por ele controlada, for atingido, restringindo o número de ajustes. Serão obtidas soluções para que o sistema elétrico opere de maneira ótima, com mínimas perdas, tensões nas barras dentro de limites rigorosamente fixados e com números mínimos de ajustes nos dispositivos controláveis. Testes numéricos com os sistemas elétricos IEEE 14, 30, 118 barras foram realizados para validar as abordagens propostas. Também foram realizados testes com outra reformulação das restrições de complementaridade proposta na literatura e com o problema de fluxo de potência ótimo reativo clássico para análise de resultados / Abstract: In this paper two approaches of resolution are proposed to treat complementarity constraints that model the performance of voltage control devices in the reactive optimal power flow problem, a proposal of reformulation of the restrictions through integer programming and the other via valid inequalities. This problem is mathematically modeled as a mixed integer nonlinear programming problem with discrete variables and complementarity constraints. The complementarity constraints in the performance of the voltage control devices (tap of the phase transformers and banks of capacitors and shunt reactors) has the objective of making feasible the implementation of the solutions obtained in large electrical systems, so that they operate only when one of the voltage limits of the bus controlled by it is reached, restricting the number of adjustments. Solutions will be obtained so that the electrical system operates optimally, with minimum losses, voltages in the buses within bounds strictly fixed and with minimum numbers of adjustments in controllable devices. Numerical tests with the electrical systems IEEE 14, 30, and 118 buses were carried out to validate the proposed approaches. We also performed tests with another reformulation of the complementarity constraints proposed in the literature and with the classical reactive optimal power flow problem for results analysis / Mestre
35

Efeitos de um campo elétrico na viscosidade e no mecanismo de riscamento do vidro soda-cal-sílica /

Ingraci Neto, Rubens Roberto. January 2018 (has links)
Orientador: Luiz Eduardo de Angelo Sanchez / Banca: Cesar Renato Foschini / Banca: Arthur Alves Fiocchi / Banca: Carlos Alberto Fortulan / Banca: Oscar Peitl Filho / Resumo: Nesta tese se investigou a redução da viscosidade do vidro soda-cal-sílica induzida pela ação de um campo elétrico e o aproveitamento desse efeito na inibição da nucleação de trincas durante o riscamento, que introduz danos similares aqueles característicos da usinagem por abrasão; assim, se introduziu um novo caminho para usinagem em modo dúctil de materiais frágeis. Os danos que são inseridos nos materiais frágeis como vidros e cerâmicas avançadas pelas etapas tradicionais de usinagem prejudicam a aplicação destes em componentes de alta confiabilidade com exatidão dimensional e geométrica. Uma vez que o regime plástico destes materiais pode ser acentuado por um campo elétrico, estudou-se a hipótese de que um método de usinagem assistido por campo elétrico pode vencer as fronteiras dos processos convencionais. Examinaram-se as relações entre o campo elétrico e a redução na viscosidade do vidro por meio de ensaios de compressão. Amostras cilíndricas aquecidas a uma taxa de 10 ºC/min e comprimidas com uma tensão inicial de 3 MPa revelaram que a temperatura de amolecimento decresceu de maneira exponencial com o aumento da intensidade do campo elétrico aplicado, caindo de 543 ºC para 418 ºC quando sob um campo elétrico de 1 000 V/cm. Os ensaios de compressão isotérmicos com a temperatura do forno a 400 ºC, 500 ºC e 550 ºC e campo elétrico de 1 000 V/cm, evidenciaram que após o início da condução da corrente elétrica pelo vidro sua viscosidade diminuiu em até 1 000 vezes e se est... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This thesis investigated the decrease of the viscosity of the soda-lime-silica glass induced by an electric field and the use of this effect in the inhibition of crack nucleation during a scratching test, which introduces damages similar to those of abrasive machining; thus presenting a new path for ductile machining of brittle materials. The damage inserted into fragile materials such as glass and advanced ceramics by traditional machining processes hamper the application of these in high reliability products with dimensional and geometric accuracy. Since the plastic regime of these materials can be accentuated by an electric field, the hypothesis that an electric field assisted machining method can overcome the boundaries of conventional processes had been studied. The relationships between the electric field and the reduction in the viscosity of the glass were examined by means of compression tests. Cylindrical samples compressed with an initial stress of 3 MPa under a constant heating rate, 10 ºC/min, revealed that the softening temperature decreased exponentially with the increase of the electric field, dropping from 543 ºC to 418 ºC when under an electric field of 1 000 V/cm. The isothermal compression tests, with furnace temperature at 400 ºC, 500 ºC and 550 ºC and electric field of 1 000 V/cm, showed that after the electric current began to flow through the glass, its viscosity decreased by up to 1 000 times and then stabilized, such as the electrical power being diss... (Complete abstract click electronic access below) / Doutor
36

Metodologia para definir um sistema de indicadores de desempenho socioambiental: um estudo de caso Coelba

Torres, Rita de Cássia Souza Ribeiro 04 October 2013 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2013-10-04T18:07:28Z No. of bitstreams: 1 Dissertação PEI - Rita de Cássia S. R. Torres.pdf: 1910330 bytes, checksum: 2dec3918ec13b9a63f6f72c1f5215f8e (MD5) / Approved for entry into archive by LIVIA FREITAS(livia.freitas@ufba.br) on 2013-10-04T18:09:14Z (GMT) No. of bitstreams: 1 Dissertação PEI - Rita de Cássia S. R. Torres.pdf: 1910330 bytes, checksum: 2dec3918ec13b9a63f6f72c1f5215f8e (MD5) / Made available in DSpace on 2013-10-04T18:09:14Z (GMT). No. of bitstreams: 1 Dissertação PEI - Rita de Cássia S. R. Torres.pdf: 1910330 bytes, checksum: 2dec3918ec13b9a63f6f72c1f5215f8e (MD5) / Em razão da pressão da sociedade civil, às medidas governamentais e o aumento da conscientização do mercado consumidor que exige, cada vez mais, uma postura responsável e transparente das empresas, o tema sustentabilidade vem sendo de fundamental importância para as organizações. O desafio atual é como medir a sustentabilidade empresarial. Existem algumas ferramentas para medir o desenvolvimento sustentável, mas um dos métodos mais utilizados para induzir e fomentar decisões estratégicas é a utilização de indicadores. Nesse contexto, este trabalho objetiva descrever a metodologia utilizada por uma distribuidora de energia elétrica na definição do sistema de indicadores de desempenho socioambiental. Neste estudo de caso utilizou-se como instrumento de coleta de dados a entrevista e análise de documentos. A pesquisa indicou que a metodologia para definir os indicadores socioambientais é alinhada com o mapa estratégico da empresa e baseia-se na premissa de que os impactos socioambientais ocorrem como consequência de suas atividades. Conclui-se que a metodologia permite a priorização de indicadores de sustentabilidade, com o objetivo de avaliar os impactos socioambientais de seus processos de negócio. Os indicadores foram definidos de modo a estabelecer o equilíbrio entre as dimensões da sustentabilidade (econômico, social e ambiental) e apoiar a tomada de decisão dos gestores quanto ao planejamento, controle e avaliação das ações de sustentabilidade empresarial. / Salvador
37

Planejamento integrado de sistemas multiarea com restrições de energia e de confiabilidade : uma abordagem via programação estocastica

Morozowski Filho, Marciano January 1995 (has links)
Tese (doutorado) - Universidade Federal do Rio de Janeiro, Coordenação dos Programas de Pos-Graduação em Engenharia / Made available in DSpace on 2012-10-16T08:11:22Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T19:25:36Z : No. of bitstreams: 1 99105.pdf: 5574296 bytes, checksum: 5f3b7cb5e934ebd278ac2e69e55ad571 (MD5)
38

Nitretação gasosa potenciostaticamente auxiliada /

Angioletto, Elídio January 1998 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T05:24:34Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T23:06:05Z : No. of bitstreams: 1 144961.pdf: 15270611 bytes, checksum: fd71ad5807bcc81e72cef0c9eea5583b (MD5)
39

Estudo de caso de envelhecimento magnético em aços elétricos de grão não orientado de baixa eficiência

Negri, Guilherme Maximiliano Reichert January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-26T03:35:17Z (GMT). No. of bitstreams: 1 299670.pdf: 3291576 bytes, checksum: b37ddfab2ad595f22a800f70104558a1 (MD5) / Sabe-se da literatura que o envelhecimento magnético está associado à precipitação de carbetos e/ou nitretos, que afetam a movimentação de paredes de domínios magnéticos, aumentando a coercividade e a energia dissipada em forma de calor. Com o objetivo de avaliar a influência do tratamento térmico descarbonetante no envelhecimento de aços elétricos, três tipos de aço GNO de baixa eficiência foram tratados em dois ciclos de tratamento diferentes: um em atmosfera úmida, outro em atmosfera seca. Em seguida, os aços já tratados foram submetidos a um tratamento térmico de envelhecimento magnético acelerado, em três temperaturas diferentes: 190ºC, 210ºC e 230ºC. Foi mostrado que apenas dois dos aços tratados a seco apresentaram envelhecimento, e que as perdas histeréticas foram as que apresentaram maior aumento. Com o auxílio do método de Arrhenius, foi estimado o tempo necessário para que os aços elétricos atingissem o máximo nível de perdas em condições normais de operação de um compressor hermético. / From literature it is known that magnetic aging is associated with the precipitation of carbides and/or nitrides. These particles affect the magnetic domain wall's movement, increasing the coercivity and the losses. In order to evaluate the influence of heat treatment in aging, three types of low efficiency GNO electrical steel were treated in two different cycles, one in a wet atmosphere, the other in a dry atmosphere. After these treatments the steels have been subjected to three different aging temperatures: 190°C, 210°C and 230ºC. It was shown that only two steel from the dry cycle had aging, and the hysteresis losses showed the greatest increase. Using the Arrhenius method, we estimated how long the electrical steels can work under normal operation temperature of a hermetic compressor until reach their maximum losses level.
40

Teoria do portfólio aplicada à previsão de recursos solar e eólico / Portfolio theory applied to solar and wind resource prevision

Lima, Marcello Anderson Ferreira Batista 14 October 2016 (has links)
LIMA, M. A. F. B. Teoria do portfólio aplicada à previsão de recursos solar e eólico. 2016. 105 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2017-02-06T12:13:28Z No. of bitstreams: 1 2016_dis_mafblima.pdf: 3767067 bytes, checksum: f60cb33702df959e03115cc616efc81d (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2017-02-23T13:46:39Z (GMT) No. of bitstreams: 1 2016_dis_mafblima.pdf: 3767067 bytes, checksum: f60cb33702df959e03115cc616efc81d (MD5) / Made available in DSpace on 2017-02-23T13:46:39Z (GMT). No. of bitstreams: 1 2016_dis_mafblima.pdf: 3767067 bytes, checksum: f60cb33702df959e03115cc616efc81d (MD5) Previous issue date: 2016-10-14 / The generation of electricity from alternative energy sources have been increasingly used in the world. Solar and wind power generators are those which stand out in terms of growth. The implementation of wind and solar power plants is restricted as to its location, because they are sources that depend on specific climatic factors. Brazil, due to its vast territory and climate, is composed of regions that can alternative energy sources for electricity generation. The challenges for the integration of electricity production sources in large scale depends mainly on predictability, flexibility of other energy sources, due to its variability. From the perspective of costs, from March to October 2010, in Germany for example, due to solar and wind forecast errors, electricity production from these sources was 2 GWh lower than expected, resulting in an additional cost of 2 20 euros per MWh generated. This work aims to adapt the Portfolio Theory to improve the solar and wind predictability, finding a limit where the combination of energy sources will result in lower prediction errors. The theory is used in the financial sector so that investment risks are reduced by diversifying applications of investors. Developed by the american Harry Markowitz in 1952, the theory has the ultimate goal of methodize the definition of penetration percentage of each asset in order to improve financial returns. The Portfolio Theory adapted to improve the predictability of alternative energy resources is little used, so this thesis is a pioneer research in Brazil. By combining 70% of wind resource and 30% of solar resource, defined by the application of portfolio theory, resulted in a reduction of risk (standard deviation) of forecast errors. For solar resource, the risk was found to be 11.24 and wind resource 7.38. After the integration proposal, the risk obtained was 6.09. This study have use of solar and wind data measurements in Maracanaú - CE. / A geração de energia elétrica a partir de fontes alternativas de energia tem sido cada vez mais empregada no mundo. Geradores elétricos solares e eólicos são os que mais se destacam em termos de crescimento. A implantação de usinas de energia eólica e solar se restringe quanto a sua localização, devido serem fontes que dependem de fatores climáticos específicos. O Brasil, devido ao seu vasto território e clima, é composto por regiões que podem explorar fontes alternativas de energia para a geração de eletricidade. Os desafios para a integração dessas fontes de produção de eletricidade em uma grande quantidade dependem principalmente da previsibilidade, da flexibilidade de outras fontes de energia, devido sua variabilidade. Na perspectiva de custos, em março a outubro de 2010, na Alemanha por exemplo, devido a erros de previsão solar e eólica, a produção de energia elétrica a partir dessas fontes foi de 2 GWh abaixo do previsto, resultando em um custo adicional de 2,20 euros por MWh gerado. A presente dissertação visa adaptar a Teoria do Portfólio ao melhoramento da previsibilidade solar e eólica, encontrando um limite em que a combinação dessas fontes de energia resulte em menores erros de previsão. A teoria é utilizada no setor financeiro para que os riscos dos investimentos sejam diminuídos através da diversificação das aplicações dos investidores. Desenvolvida pelo norte americano Harry Max Markowitz no ano de 1952, a teoria tem por objetivo final metodizar a definição do percentual de penetração de cada ativo a fim de melhores retornos financeiros. A Teoria do Portfólio adaptada para aperfeiçoar a previsibilidade de recursos alternativos de energia é pouco utilizada, portanto a presente dissertação constitui pesquisa pioneira no Brasil. Através da combinação de 70% de recurso eólico e 30% de recurso solar, definidos pela aplicação da Teoria do Portfólio, houve diminuição de riscos (desvio padrão) de erros de previsão. Em relação ao recurso solar, o risco encontrado foi de 11,24 e em relação ao recurso eólico 7,38. Após a integração proposta, o risco obtido foi de 6,09. O presente trabalho utilizou-se de medições de dados solares e eólicos realizadas em Maracanaú – CE.

Page generated in 0.0618 seconds