Spelling suggestions: "subject:"eletrodegradação"" "subject:"eletrodegradações""
1 |
Desenvolvimento de metodologia para eletrodegradação de ciprofloxacina por agentes oxidantes gerados in situSilva, Jaime Rodrigues da 28 August 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Environmental contamination by drugs of antibiotic action can bring as a consequence the development of more resistant bacteria, altering the microbial community structure in nature. Due to its widespread use, ciprofloxacin has been identified in trace concentrations in sewage treatment plants (STPs) and surface waters, since the conventional processes of wastewater treatment does not remove the usual drugs completely, these substances have been detected in drinking water, which represents a direct risk to humans, since the constant contamination of water may be associated with the continuous process and reuse of the water increasing worldwide. In this study, a method of electrochemical oxidation of ciprofloxacin, since the transfer of electrons, drugs can be processed, biodegraded or mineralized. The electrochemical oxidation of the drugs can occur in a satisfactory manner, the surface of some anode metal oxide, capable of generating oxygen and simultaneously with the formation of higher oxides or superoxide. This mechanism is at the surface of ADE ® coated and immobilized metal oxides. To identify and monitor the change in concentration of ciprofloxacin was analyzed their absorption spectra in the ultraviolet and visible (200-800 nm). Ciprofloxacin in aqueous solution shows two absorption peaks in completely different bands and with maximum at 270 nm and 315 nm. The nature of the electrolyte and the pH had great influence on the speed of the degradation process. In the midst of Cl- was a more efficient degradation. In studies with HCl, NaCl and KCl was observed 100% removal of the yellow color characteristic of the presence of Cl-anion and subsequent formation of hypochlorite (ClO-). In turn, the pH was a limiting factor in this process, where it was observed that the reaction proceeds in most satisfactorily at pH values below 4.0. The current that showed the best result was 80 mA. The method of supplying water to said acid chloride in ciprofloxacin can be completely degraded within 5 min. / A contaminação ambiental por fármacos de ação antibiótica pode trazer como consequência o desenvolvimento de bactérias mais resistentes, alterando a estrutura da comunidade microbiana na natureza. Devido a sua ampla utilização, a ciprofloxacina vem sendo identificada em concentrações-traço em estações de tratamento de esgotos (ETEs) e águas superficiais, uma vez que os processos convencionais de tratamento de efluentes usuais não removem os fármacos completamente, essas substâncias têm sido detectadas em águas potáveis, o que caracteriza um risco direto para os seres humanos, visto que a constante contaminação das fontes de água pode ser associada ao processo contínuo e crescente de reutilização da água em todo o mundo. Neste estudo foi desenvolvido um método de oxidação eletroquímica da ciprofloxacina, uma vez que na transferência de elétrons, os fármacos podem ser transformados, biodegradados ou mineralizados. A oxidação eletroquímica dos fármacos pode ocorrer de forma satisfatória, na superfície de alguns ânodos de óxidos metálicos, em condições de geração simultânea de oxigênio e com a formação de óxidos superiores ou superóxidos. Este mecanismo é observado na superfície dos ADE® revestidos e imobilizados por óxidos metálicos. Para identificar e acompanhar a mudança de concentração da ciprofloxacina foi analisado o seu espectro de absorção na região do ultravioleta e visível (200-800 nm). A ciprofloxacina em solução aquosa apresenta dois picos de absorção em bandas completamente distintas e com máximos em 270 nm e 315 nm. A natureza do eletrólito e o pH apresentou grande influência na velocidade do processo de degradação. Em meio a Cl- ocorreu uma maior eficiência na degradação. Nos estudos com HCl, NaCl e KCl foi observado 100% de remoção da cor amarelada, característica da presença do ânion Cl- e da posterior formação de hipoclorito (ClO-). Por sua vez, o pH foi um dos fatores limitantes deste processo, onde foi possível observar que a reação acontece de maneira mais satisfatória em valores de pH abaixo de 4,0. A corrente que apresentou o melhor resultado foi de 80mA. A aplicação do método em água de abastecimento indicou que em meio ácido contendo cloreto a ciprofloxacina pode ser completamente degradada em apenas 5 min.
|
2 |
Desenvolvimento de metodologias eletroquímicas para monitoramento ambiental da rifampicina e sua eletrodegradação pela geração de agentes oxidantes in situSantos, Renê Humberto Tavares 25 October 2010 (has links)
The drugs are considered pollutant emergent, a time that its presence in aquatic environments is each bigger time. This research has as objective to develop electrochemical methodologies that allow to monitor and to degrade the rifampicin in water of public supplying. In the stage of monitor a voltammetric method was developed using a biosensor of chitosan for rifampicin analysis. Parallel to this study was development and optimized a electrodegradation method using electrode of the type Dimensionally Stable Anodes DSA® (Ti/RuO2 - TiO2). The voltammetric behavior of the rifampicin in the biosensor of chitosan using itself it technique of
differential pulse voltammetry on indicates the presence of a peak of irreversible oxidation in 0,492 V (versus Ag/AgCl) corresponding the electronic transference of two electrons for molecule. The study of the effect of the speed of sweepings and pH of the way they indicate to be about a electrodic process with diffusional and dependent control of pH. The voltammetric method of determination of the rifampicin
presents a recovery of 110% for 1,0 10-5 mol.L-1. From the experiments of electrodegradation of the rifampicin under electrodes DSA® it was evaluated influence of the chain density, getting as excellent value 120 mA cm-2. For the
different assays in pHs, it was possible to observe that the half reacionais with pHs 8 and 3 favor the electrolysis of the rifampicin for this type of reactor in NaCl as electrolyte has supported with electrodegradation of 100% of organic molecules of the rifampicina in only 72s and 84s in these half reationais. Being that in only 48s the molecule of the rifampicin total is degraded, in turn, its by-products have a time of 24 electrodegradation of and 36s. The application in water of supplying with accompaniment of the loss of color was made through spectrophotometry in the region of UV-Visible, in =370 nm. It approximately had a complete removal of the color and total reduction of the absorbance in the electrodegradation of the rifampicin in 96 and 84s of electrolysis in the two studied ways, pH 3 and 8 respectively. / Os fármacos são considerados poluentes emergentes, uma vez que sua presença em ambientes aquáticos é cada vez maior. Essa pesquisa tem como objetivo desenvolver metodologias eletroquímicas que permitam monitorar e degradar a rifampicina em água de abastecimento público. Na etapa de monitoramento foi desenvolvido um método voltamétrico empregando um biossensor de quitosana
para análise de rifampicina. Paralelo a este estudo foi desenvolvimento e otimizado um método de eletrodegradação empregando eletrodo do tipo Ânodo Dimensionalmente Estável ADE® (Ti/RuO2 TiO2). O comportamento voltamétrico
da rifampicina no biossensor de quitosana empregando-se a técnica de voltametria de pulso diferencial evidencia a presença de um pico de oxidação irreversível em 0,492 V (vs Ag/AgCl) correspondente a transferência eletrônica de dois elétrons por molécula. O estudo do efeito da velocidade de varredura e do pH do meio indicaram tratar-se de um processo eletródico com controle difusional e dependente do pH. O método voltamétrico de determinação da rifampicina apresentou uma recuperação de 110% para 1,0 10-5 mol.L-1. Nos experimentos de eletrodegradação da rifampicina sob eletrodos ADE® Foi avaliada a influência da densidade de corrente, obtendo como valor ótimo 120 mA cm-2. Para os ensaios em diferentes valores de pH, foi possível observar que os meios reacionais com pH 8 e 3 favoreceram a
eletrólise da rifampicina para este tipo de reator em NaCl como eletrólito suporte com eletrodegradação de 100% das moléculas orgânicas da rifampicina em apenas 72s e 84s nestes meios racionais. Sendo que em apenas 48s a molécula da rifampicina foi totalmente degradada, por sua vez, seus subprodutos tiveram um tempo de eletrodegradação de 24 e 36s. A aplicação em água de abastecimento com acompanhamento da perda de cor foi feita por espectrofotometria na região do UV-Vis, em =370 nm. Houve uma remoção completa da cor e redução total da absorbância na eletrodegradação da rifampicina em aproximadamente 96 e 84s de eletrólise nos dois meios estudados, pH 3 e 8 respectivamente.
|
Page generated in 0.0547 seconds