• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Eliminación biológica de nutrientes en un reactor biológico secuencial.- Caracterización y estimulación de las fuentes de carbono del agua residual urbana.

Barajas López, María Guadalupe 05 April 2002 (has links)
Los objetivos de esta tesis doctoral son la caracterización de un agua residual urbana, la prefermentación del agua residual y la optimización de la eliminación biológica de nutrientes en el tratamiento del agua residual en un reactor biológico secuencial (RBS). El agua residual de una zona residencial de Barcelona se caracterizó mediante parámetros típicos de las aguas residuales y, específicamente, mediante los ácidos grasos volátiles (AGV), el potencial de ácidos grasos volátiles (potencial de AGV) y la DQO fraccionada, con el fin de evaluar su aptitud a la eliminación biológica de fósforo. Se desarrolló una modificación del método original del potencial de AGV, que simplifica el procedimiento.Los valores promedio del agua residual afluente fueron: 282 mg/l MES, 472 mg/l DQO, 39 mg/l NT, 30 mg/l N-NH4, 12 mg/l PT, 7 mg/l P-PO4 soluble. Aunque se encontraron valores bajos de AGV (8,5 mg/l) y de la ratio VFA/PT (0,71 mg DQO/mg P), el potencial de AGV (118 mg/l) y la ratio potencial AGV/PT (18 mg DQO/mg P) fueron comparables con los valores recomendados para la eliminación biológica de fósforo. Del análisis del fraccionamiento de la DQO y de los datos del potencial de AGV se concluyó que la mayor parte de la DQO fácilmente biodegradable y, probablemente una fracción de la lentamente biodegradable, se emplearon para la producción de AGV, en la prueba del potencial de AGV.Se diseñó un ciclo complejo de 6 h para optimizar la eliminación biológica de nutrientes (EBN): llenado estático (1 h), llenado anóxico (0,75 h), llenado aireado (0,25 h), llenado anóxico (0,75 h), llenado aireado (0,25 h), reacción aeróbica (1,5 h), reacción postanóxica (0,75 h), decantación (0,63 h) y vaciado (0,12 h). El tiempo de llenado representó el 50% del total, mientras que la aireación supuso el 33% del tiempo del ciclo. El oxígeno disuelto se controló con un regulador PID, con un punto de consigna de 2,0 mg/l. El tiempo de retención hidráulico (TRH) fue de 8 h y el tiempo de retención de sólidos (TRS) de 24 d. El RBS, de 24 litros, se alimentó con el agua residual en dos fases experimentales diferentes. En la Fase 1, el reactor se alimentó con agua residual cruda. En la Fase 2, el agua residual cruda se alimentó a un decantador primario continuo, explotado como un prefermentador (tanque primario activado, TPA) y su efluente se utilizó para alimentar el RBS. En la Fase 1, los valores del efluente fueron: 39 mg/l MES, 87 mg/l DQO, 8.9 mg/l NT, 1.3 mg/l PT. Las concentraciones de nutrientes quedaron por debajo del límite para poblaciones entre 10.000 y 100.000 habitantes-equivalentes. El llenado estático permitió condiciones fuertemente anaeróbicas durante el llenado, lo que mejoró la eliminación biológica de fósforo. Además, la nitrificación y desnitrificación simultánea, junto con la fase postanóxica, permitieron mejorar la eliminación de nitrógeno.En la Fase 2, se diseño y estudió un TPA con el fin de analizar el efecto de la separación de sólidos primarios y de su prefermentación en el funcionamiento del RBS. El prefermentador, de 3 litros, operó bajo las condiciones siguientes: TRH 1,3 h, TRS 5 y 10 d, recirculación 52% y velocidad del rascador 0,5 rpm. El mejor funcionamiento se consiguió con un TRS de 5 d y con el prefermentador cubierto para un mejor control de la temperatura y el potencial de oxidación-reducción. En estas condiciones se observó solubilización de DQO (22 mg/l) y formación de AGV (34 mg/l). Aunque la fermentación acidogénica fue considerable, la producción de AGV alcanzó sólo el 35% del potencial de AGV del agua residual cruda. Este hecho se atribuyó al flujo no completamente mezclado, intrínseco del prefermentador. El efecto de retención de sólidos en el prefermentador predominó sobre el efecto de fermentación y solubilización, y la eliminación de nutrientes se vio perjudicada, especialmente la eliminación de fósforo. Los valores del efluente en esta fase fueron: 28 mg/l MES, 55 mg/l DQO, 11 mg/l NT, y 5.3 mg/l PT.
2

Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP

Knobelsdorf Miranda, Juliana 14 July 2005 (has links)
El objetivo principal de esta tesis doctoral es profundizar en el conocimiento de los procesos biológicos responsables de la eliminación simultánea de nitrógeno y fósforo en un ARU de baja carga orgánica, mediante un reactor de flujo continuo del tipo Virginia Initiative Plant (VIP). Se han evaluado los parámetros limitantes del proceso y las formas de promover la disponibilidad de la materia orgánica fácilmente biodegradable para los OAF. Se ha llevado a cabo una caracterización de los parámetros físico-químicos del ARU, así como de sus fuentes de carbono, incluyendo la aportación de un sustrato externo, con el fin de determinar y estimular su aptitud para la EBIF. Se ha sistematizado el fraccionamiento de la DQO y la estimación del contenido de AGV y del potencial de AGV, mediante el desarrollo de una alternativa del método original para valorar el potencial de AGV, que simplifica el procedimiento operativo. Aunque el contenido de AGV fue bajo, el potencial de AGV y la fracción potencial AGV/PT fueron comparables a los valores recomendados para la EBIF. La mayor parte de la DQOFB y una fracción de la DQOLB se transformaron en AGV durante el ensayo del potencial de AGV. La aportación de acetato sódico permitió aumentar y mantener un porcentaje medio de AGV del 74% de la DQOFB, del 42% de la DQOs y del 20% de la DQO. La DQO del afluente sin decantar estuvo compuesta mayoritariamente por DQOBT (75% DQOLB y 25% DQOFB). Los incrementos de la DQOFB se tradujeron en incrementos de la DQOs. La mayor parte de la DQOLB del afluente estuvo formada por materia orgánica particulada, haciendo que la presencia de MES en el afluente fuera determinante para incrementar la aportación de DQOLB al sistema.Los rendimientos de eliminación fueron del 85% de la MES, el 87% de la DQO, el 99% del amoníaco y el 42% del P. La mayor eliminación de DQO se registró en la zona anaerobia, con independencia del grado de subdivisión del reactor. La DQO residual se eliminó progresivamente en las siguientes zonas del reactor (89%, 3,8%, 1,7% y 2,2%). La fracción F/M en la zona de contacto inicial estuvo determinada en gran medida por la subdivisión aplicada al reactor biológico.La mayor concentración de PT del efluente se registró los días con mayor recirculación de nitratos al reactor anaerobio y aquellos con episodios de bulking, debido a la adición de un exceso de sustrato. Concentraciones de nitratos en el afluente al reactor anaerobio superiores a 0,20 mg N/L se tradujeron en una liberación de fósforo inferior a 1 mg P/L. A medida que el flujo de nitratos recirculados al reactor anaerobio aumentó, la liberación de P registró una disminución progresiva, rebajando su asimilación posterior en el reactor aerobio. El valor medio de la fracción DQO/PT en el afluente fue inferior al recomendado en la bibliografía (77 mg/mg) para una óptima eliminación simultánea de nutrientes. La fracción DQO/PT máxima (72 mg/mg) se alcanzó agregando un sustrato externo fácilmente biodegradable. La menor concentración de P del efluente se alcanzó con valores altos de la fracción DQO/PT. La relación consumo/liberación de P registró un valor medio de 1,14, si se incluye la liberación en los reactores anaerobios y anóxicos, y de 1,57 si sólo se tiene en cuenta la liberación en el reactor anaerobio. La eliminación de P disminuyó cuando la adición de acetato sódico alcanzó 150 mg DQO/L, debido a un deterioro rápido de la decantabilidad del fango por formación de bulking. La asimilación de P en la zona aerobia fue proporcional a la liberación de P en la zona anaerobia. La liberación de P en la zona anóxica pudo ocurrir como resultado de la fermentación de una fracción de la DQOLB presente en esta zona. / The main objective of this thesis is to advance the knowledge of the biological processes for simultaneous removal of nitrogen and phosphorous from a low-strength municipal wastewater using a continuous flow reactor, based on a Virginia Initiative Plant (VIP) design. An evaluation was conducted of the limiting parameters of the process and the strategies for promoting the availability of easily biodegradable organic matter to the PAO microorganisms. A follow-up was conducted of common wastewater physico-chemical parameters, and its sources of carbon, including the contribution from an external substrate, to determine and promote its potential for the enhanced biological phosphorus removal (EBPR) process. A new protocol was developed for COD fractionation, and for estimating the VFA concentration and the VFA potential, using a modified VFA potential test that simplifies the original operating procedure.Although the VFA content was generally low, the values of the VFA potential and the VFA potential/P ratio were comparable to those required by the EBPR process. Most of the RBCOD and a fraction of the SBCOD were readily converted to VFA during the VFA potential test. The addition of sodium acetate contributed to increase and maintain a mean percentage of VFA at 74% of the RBCOD, 42% of the SCOD and 20% of the COD. The COD of the unsettled influent was mainly formed by TBCOD (75% SBCOD, and 25% RBCOD). Increments of RBCOD translated into increments of SCOD. Most of the influent SBCOD corresponded to particulate organic matter, making the influent TSS content a determining factor for increasing the SBCOD contribution to the system. The removal efficiencies were 85% for TSS, 87% for COD, 99% for ammonia, and 42% for P. The highest COD removal efficiencies were observed in the anaerobic zone, regardless of the reactor subdivision arrangement adopted. The residual COD was removed in subsequent zones of the reactor (89%, 3.8%, 1.7%, and 2.2%). The F/M ratio in the initial contact zone was largely determined by the reactor subdivision adopted. The highest effluent TP concentration was observed during the days with the largest nitrate recirculation rates to the anaerobic reactor, and also during bulking episodes generated by an excessive substrate addition. Influent nitrate concentration to the anaerobic reactor higher than 0.20 mg N/L resulted in a phosphorous release lower than 1 mg P/L. As the recycled nitrates flow to the anaerobic reactor increased, the phosphorous release rates showed a steady decrease, preventing its subsequent uptake in the aerobic reactor. The mean influent COD/TP ratio was lower than that recommended in the literature (77 mg/mg) for an optimum simultaneous nutrient removal process. The maximum COD/TP ratio (72 mg/mg) was reached by adding an easily biodegradable external substrate. The lowest effluent P concentration was observed with high values of the COD/TP ratio. The mean P uptake/release ratio observed was 1.14, when P release from the anaerobic and anoxic reactors was included, while it reached 1.57 when only the release at the anaerobic reactor was considered. Phosphorous removal decreased when sodium acetate addition reached 150 mg COD/L, due to a rapid deterioration of the sludge settling properties caused by bulking. Phosphorous uptake in the aerobic zone was proportional to P release in the anaerobic zone. Phosphorous release in the anoxic zone may have occurred by partial fermentation of the SBCOD input to this reactor zone.
3

Operation and control of SBR processes for enhanced biological nutrient removal from wastewater

Puig Broch, Sebastià 15 January 2008 (has links)
In the last decades, the awareness of environmental issues has increased in society considerably. There is an increasing need to improve the effluent quality of domestic wastewater treatment processes. This thesis describes the application of the Sequencing Batch Reactor (SBR) technology for Biological Nutrient Removal (BNR) from the wastewater. In particular, the work presented evolves from the nitrogen removal to the biological nutrient removal (i.e. nitrogen plus phosphorous removal) with special attention to the operational strategy design, the identification of possible reactor cycle controls or the influent composition related to the process efficiency. In such sense, also the use of ethanol as an external carbon (when low influent Carbon:Phosphorus (C:P) or Carbon:Nitrogen (C:N) ratios are presented) are studied as an alternative to maintain the BNR efficiency.
4

SBR technology for wastewater treatment: suitable operational conditions for a nutrient removal

Vives Fàbregas, M. Teresa 29 November 2004 (has links)
Actualment, la legislació ambiental ha esdevingut més restrictiva pel que fa a la descàrrega d'aigües residuals amb nutrients, especialment en les anomenades àrees sensibles o zones vulnerables. Arran d'aquest fet, s'ha estimulat el coneixement, desenvolupament i millora dels processos d'eliminació de nutrients.El Reactor Discontinu Seqüencial (RDS) o Sequencing Batch Reactor (SBR) en anglès, és un sistema de tractament de fangs actius que opera mitjançant un procediment d'omplerta-buidat. En aquest tipus de reactors, l'aigua residual és addicionada en un sol reactor que treballa per càrregues repetint un cicle (seqüència) al llarg del temps. Una de les característiques dels SBR és que totes les diferents operacions (omplerta, reacció, sedimentació i buidat) es donen en un mateix reactor. La tecnologia SBR no és nova d'ara. El fet, és que va aparèixer abans que els sistema de tractament continu de fangs actius. El precursor dels SBR va ser un sistema d'omplerta-buidat que operava en discontinu. Entre els anys 1914 i 1920, varen sorgir certes dificultats moltes d'elles a nivell d'operació (vàlvules, canvis el cabal d'un reactor a un altre, elevat temps d'atenció per l'operari...) per aquests reactors. Però no va ser fins a finals de la dècada dels '50 principis del '60, amb el desenvolupament de nous equipaments i noves tecnologies, quan va tornar a ressorgir l'interès pels SBRs. Importants millores en el camp del subministrament d'aire (vàlvules motoritzades o d'acció pneumàtica) i en el de control (sondes de nivell, mesuradors de cabal, temporitzadors automàtics, microprocessadors) han permès que avui en dia els SBRs competeixin amb els sistemes convencional de fangs actius.L'objectiu de la present tesi és la identificació de les condicions d'operació adequades per un cicle segons el tipus d'aigua residual a l'entrada, les necessitats del tractament i la qualitat desitjada de la sortida utilitzant la tecnologia SBR. Aquestes tres característiques, l'aigua a tractar, les necessitats del tractament i la qualitat final desitjada determinen en gran mesura el tractament a realitzar. Així doncs, per tal d'adequar el tractament a cada tipus d'aigua residual i les seves necessitats, han estat estudiats diferents estratègies d'alimentació.El seguiment del procés es realitza mitjançant mesures on-line de pH, OD i RedOx, els canvis de les quals donen informació sobre l'estat del procés. Alhora un altre paràmetre que es pot calcular a partir de l'oxigen dissolt és la OUR que és una dada complementària als paràmetres esmentats.S'han avaluat les condicions d'operació per eliminar nitrogen d'una aigua residual sintètica utilitzant una estratègia d'alimentació esglaonada, a través de l'estudi de l'efecte del nombre d'alimentacions, la definició de la llargada i el número de fases per cicle, i la identificació dels punts crítics seguint les sondes de pH, OD i RedOx. S'ha aplicat l'estratègia d'alimentació esglaonada a dues aigües residuals diferents: una procedent d'una indústria tèxtil i l'altra, dels lixiviats d'un abocador. En ambdues aigües residuals es va estudiar l'eficiència del procés a partir de les condicions d'operació i de la velocitat del consum d'oxigen. Mentre que en l'aigua residual tèxtil el principal objectiu era eliminar matèria orgànica, en l'aigua procedent dels lixiviats d'abocador era eliminar matèria orgànica i nitrogen.S'han avaluat les condicions d'operació per eliminar nitrogen i fòsfor d'una aigua residual urbana utilitzant una estratègia d'alimentació esglaonada, a través de la definició del número i la llargada de les fases per cicle, i la identificació dels punts crítics seguint les sondes de pH, OD i RedOx.S'ha analitzat la influència del pH i la font de carboni per tal d'eliminar fòsfor d'una aigua sintètica a partir de l'estudi de l'increment de pH a dos reactors amb diferents fonts de carboni i l'estudi de l'efecte de canviar la font de carboni. Tal i com es pot veure al llarg de la tesi, on s'han tractat diferents aigües residuals per a diferents necessitats, un dels avantatges més importants d'un SBR és la seva flexibilitat. / Actualmente, la legislación ambiental se ha convertido más restrictiva por lo que concierne al vertido de aguas residuales con nutrientes, especialmente en las llamadas áreas sensibles o zonas vulnerables. A partir de este hecho, se ha estimulado el conocimiento, desarrollo y mejora de los procesos de eliminación de nutrientes.El Reactor Discontinuo Secuencial (RDS) o Sequencing Batch Reactor (SBR) en inglés, es un sistema de tratamiento de fangos activados que opera mediante un procedimiento de llenado-vaciado. En este tipo de reactores, el agua residual es adicionada en un solo reactor que trabaja por cargas repitiendo un ciclo (secuencia) a lo largo del tiempo. Una de les características de los SBR es que todas las diferentes operaciones (llenado, reacción, sedimentación y vaciado) se dan en el mismo reactor. La tecnología SBR no es nueva. De hecho, apareció antes que el sistema de tratamiento continuo de fangos activados. El precursor de los SBR fue un sistema de llenado-vaciado que operaba en discontinuo. Entre los años 1914 y 1920, surgieron ciertas dificultades muchas de ellas a nivel de operación (válvulas, cambios de caudal de un reactor a otro, elevado tiempo de atención por parte del operario...) para estos reactores. Pero no fue hasta finales de la década de los '50 principios de los '60, con el desarrollo de los nuevos equipamientos y las nuevas tecnologías, cuando volvió a resurgir el interés en los SBRs. Importantes mejoras en el campo de los suministro de aire (válvulas motorizadas o de acción neumática) y en el de control (sondas de nivel, medidores de caudal, temporizadores automáticos, microprocesadores) han permitido que hoy en día los SBRs compitan con los sistemas convencionales de fangos activados.El objetivo de la presente tesis es la identificación de las condiciones de operación adecuadas para un ciclo según el tipo de agua residual en la entrada, las necesidades del tratamiento y la calidad deseada de la salida utilizando la tecnología SBR. Estas tres características, el agua a tratar, las necesidades del tratamiento y la calidad final deseada determinan en gran medida el tratamiento a realizar. Así pues, para poder adecuar el tratamiento a cada tipo de agua residual y a sus necesidades, han sido estudiados diferentes estrategias de alimentación. El seguimiento de los cambios de las medidas en línea de pH, OD y RedOx proporciona información sobre el proceso. A su vez, otro parámetro que se puede calcular a partir del OD es la OUR que también da información del proceso.Se han evaluado las condiciones de operación para eliminar nitrógeno de una agua residual sintética utilizando una estrategia de alimentación escalonada, a partir del estudio del efecto del número de alimentaciones, la definición de la longitud y el número de fases por ciclo, y la identificación de los puntos críticos siguiendo las sondas de pH, OD y RedOx.Se ha aplicado la estrategia de alimentación escalonada a dos aguas residuales diferentes: una procedente de una industria textil y la otra, de los lixiviados de un vertedero. En las dos aguas residuales se estudió la eficiencia del proceso a partir de las condiciones de operación y de la velocidad de consumo de oxigeno. Mientras que en el agua residual textil el principal objetivo era eliminar materia orgánica, en el agua procedente de los lixiviados del vertedero era eliminar materia orgánica y nitrógeno.Se han evaluado las condiciones de operación para eliminar nitrógeno y fósforo de una agua residual urbana utilizando una estrategia de alimentación escalonada, a partir del estudio de la definición de la longitud y el número de fases por ciclo, y la identificación de los puntos críticos siguiendo las sondas de pH, OD y RedOx.Se han analizado la influencia del pH y la fuente de carbono para eliminar fósforo de un agua sintética a partir del estudio del incremento de pH en dos reactores con diferentes fuentes de carbono y el estudio del efecto de cambiar la fuente de carbono.Como se puede apreciar a lo largo de la tesis, donde se han tratado diferentes aguas residuales para a diferentes necesidades, una de las ventajas más importantes de los SBR es su flexibilidad. / Nowadays, environmental legislation has become more restricted in the nutrient wastewater discharge, especially in the sensitive areas and vulnerable zones. So, many studies have been stimulated on the understanding, developing and improving the biological nutrient removal processes.The Sequencing Batch Reactor (SBR) is a fill-and-draw activated sludge system for wastewater treatment. In this system, wastewater is added to a single reactor which operates in a batch treatment mode repeating a cycle (sequence) continuously. All the operations (fill, react, settle and draw) are achieved in a single batch reactor. SBR technology is not new. In fact, it precedes the use of continuous flow activated sludge technology. The precursor to this was a fill-and-draw system operated on batch, similar to the SBR. Between 1914 and 1920, many difficulties were associated with operating these fill-and-draw systems, most resulting from the process valving required to switch flow from one reactor to another, operator attention required. Interest in SBRs was revived in the late 1950s and early 1960s, with the development of new equipment and technology. Improvements in aeration devices (i.e. motorized valves, pneumatically actuated valves) and controls (level sensors, flowmeters, automatic timers, microprocessors) have allowed SBRs to successfully compete with conventional activated sludge systems.The aim of this thesis consists in the identification of suitable operation conditions for a cycle according to kind of influent wastewater, treatment requirements and effluent quality using a SBR technology. The influent wastewater, treatment requirements and effluent quality desire determinate in great measure the treatment to realize. So, different studies have been carried out in order to obtain a suitable treatment for each wastewater and requirement using a step-feed strategy.By means of on-line pH, DO and ORP measurements are possible follow the status of the process. At the same time another parameter, that complements all these, is the OUR calculated through DO dada.Evaluation the operation conditions for nitrogen removal using a step-feed strategy for a synthetic wastewater through the study of the effect of number of filling events, the definition of the length and number of phases for a cycle, and the identification of the critical points following the pH, DO and ORP sensors. Application of the step-feed strategy in two different industrial wastewaters: textile wastewater and landfill leachate wastewater. In both wastewaters, the efficiency has been studied through the operational conditions and oxygen uptake rate. While in the textile wastewater the main objective was only organic matter removal, in the landfill leachate wastewater was carbon and nitrogen removal.Evaluation of the operation conditions for nitrogen and phosphorus removal using a step-feed strategy for an urban wastewater through, the definition of the number and length of phases for a cycle, and the identification of the critical points following the pH, DO and ORP sensors.Influence of pH and carbon source in phosphorus removal using synthetic wastewater through the study of pH increase in two different carbon sources and the effect of change of carbon source.As it can be observed in this thesis, where it is treated different wastewaters for different requirements, one of the main advantages of the SBR is its flexibility.

Page generated in 0.1305 seconds