• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 8
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 40
  • 33
  • 18
  • 12
  • 10
  • 10
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Carotid artery stenosis : surgical aspects /

Kragsterman, Björn, January 2006 (has links)
Diss. (sammanfattning) Uppsala : Uppsala universitet, 2006. / Härtill 5 uppsatser.
12

Coupled hemodynamics and mechanics of the repaired human carotid artery

Kamenskiy, Alexey. January 2009 (has links)
Thesis (Ph.D.)--University of Nebraska-Lincoln, 2009. / Title from title screen (site viewed February 25, 2010). PDF text: 1 v. (ca. 280 p. : ill.). UMI publication number: AAT 3386755. Includes bibliographical references. Also available in microfilm and microfiche formats.
13

Operative Versorgung von Karotisstenosen in Kombination mit herzchirurgischen Eingriffen an der extrakorporalen Zirkulation / Carotid Endarterectomy combined with Heart Surgery using Cardiopulmonary Bypass

Pölert, Nicolas 14 June 2017 (has links)
No description available.
14

Cerebral haemodynamic control and carotid endarterectomy : comparison of general and locoregional anaesthesia

Dellagrammaticas, Demosthenes January 2012 (has links)
The role of CEA for stroke prevention in the presence of symptomatic carotid artery stenosis is well established. In order to maximize the benefit of surgery, several perioperative processes of care have been under scrutiny, of which one is the choice of anaesthetic method. The differing effects of GA vs. LA on the cerebral circulation after CEA may be of significance, since changes in the cerebral circulation post-CEA may give rise to cerebral hyperperfusion and intracerebral haemorrhage. This work assessed the effect of GA vs. LA on cerebral haemodynamic control after CEA using transcranial Doppler (TCD) techniques, and correlated these changes with serum markers of cerebral injury. Subjects undergoing CEA had perioperative TCD monitoring of middle cerebral artery blood flow velocity (MCAV). Pre- and postoperative (within 48 hours of surgery) testing of cerebral autoregulation [CA] (tilt-testing) and cerebral vasoreactivity to CO2 [CVR] (rebreathing expired air) was conducted. Cerebral haemodynamic parameters and clinical outcome were correlated with changes in jugular venous and peripheral levels of protein S100β and neurone-specific enolase (NSE).The change in CA and CVR was not different between GA (n=16) and LA (n=20). Overall, CA and CVR improved significantly within 48 hours of CEA for patients with preoperative impairment of these parameters, although some patients with normal baseline CA and CVR exhibited postoperative impairment. Increase of MCAV >100% from baseline after restoration of carotid blood flow was observed in patients with impaired CVR, but resolved by the first postoperative day. Transient elevation in jugular venous (but not peripheral) S100β during surgery was seen. Both jugular and peripheral NSE levels dropped during surgery. Neither anaesthetic method nor CA or CVR status had any effect on changes in serum S100β or NSE. Cerebral autoregulatory parameters thus improve rapidly after CEA, but appear unaffected by anaesthetic technique. This supports the concept that cerebral hyperperfusion is dependent on factors in addition to impaired CA or CVR. Changes in serum S100β or NSE do not reflect cerebral haemodynamic changes. However, the variability encountered between patients warrants further investigation. The implications for clinical practice and directions for further research are discussed.
15

Análise comparativa dos parâmetros adquiridos com o US doppler transcraniano durante a endarterectomia carotídea por semi-eversão e a angioplastia carotídea / A comparative analysis of transcranial doppler parameters acquired during semi-eversion carotid endarterectomy and carotid stenting

Oliveira, Germano da Paz, 1982- 24 August 2018 (has links)
Orientador: Ana Terezinha Guillaumon / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T11:44:57Z (GMT). No. of bitstreams: 1 Oliveira_GermanodaPaz_M.pdf: 4750891 bytes, checksum: 517650637fcacb4ffebc12ad859189bb (MD5) Previous issue date: 2014 / Resumo: Objetivos: Analisar a distribuição temporal de sinais de microembolias (SM) ao longo de diferentes estágios da endarterectomia carotídea (EC) e da angioplastia carotídea (AC) e as variáveis associadas com a ocorrência destes sinais, além de avaliar as mudanças na velocidade média aferida na artéria cerebral média (ACM) durante os dois tipos de intervenção. Material e métodos: Trinta e três pacientes com estenose carotídea foram submetidos ou a EC (17) ou a AC (16). Os SM bem como as velocidades médias na ACM foram adquiridas utilizando o US doppler transcraniano (DTC) e esses dados então analisados e associados a diferentes estágios cirúrgicos (pré-proteção, durante a proteção e pós-proteção), tipos de intervenção (EC ou AC) e diferentes variáveis para encontrar potenciais fatores de risco para embolização. Para análise estatística, foram usados os testes de Qui-quadrado, de Fisher e de Mann-Whitney, além de análise por medidas repetidas das variâncias com transformação por postos (ANOVA), seguido de teste de perfil por contrastes e análise de regressão linear múltipla ajustada para o grupo. Resultados: Uma diferença significativa foi encontrada para o número de SM em ambos os grupos. Houve, em média, 89,8 (± 171,4) sinais por procedimento no grupo EC, enquanto a média no grupo AC foi de 597,5 (± 343,3) sinais por procedimento. A média da velocidade média na ACM foi, em ambos os grupos, significantemente menor no estágio durante a proteção. Anestesia local correlacionou-se positivamente (p=0,003) com aumento dos SM, e, associado a isso, o histórico de tabagismo importante (desde que houvesse a cessação do vício há mais de um ano) correlacionou-se negativamente (0,014) com a ocorrência de SM. Conclusão: EC por semi-eversão, à luz do DTC, provocou uma menor incidência de SM por procedimento do que AC com filtro distal, em todos os estágios cirúrgicos. A média da velocidade média na ACM se comportou de maneira similar em ambos os grupos (EC e AC). Anestesia geral e histórico de tabagismo importante (desde que o paciente houvesse cessado por menos um anos antes da intervenção) foram as únicas duas variáveis no estudo que se correlacionaram significativamente (negativamente) com a ocorrência de SM / Abstract: Objectives: To analyze the temporal distribution of microembolic signals throughout the different stages of both the semi-eversion carotid endarterectomy (CEA) and the carotid artery stenting (CAS) procedures and the variables associated with occurrence of them and to evaluate changes in mean blood flow velocity, for both CAS and CEA, within the ipsilateral middle cerebral artery (MCA). Methods: Thirty three patients with carotid stenosis underwent either a CEA (17) or a CAS (16). Microembolic signals, as well as mean blood flow velocity, were acquired using a Transcranial Doppler scan (TCD) and these data were then analyzed and associated to different surgical stages (pre-protection, during protection, and post-protection), types of procedure (CAS or CEA) and different variables to find potential risk factors. To statistical analysis, chi-squared test, Fisher test, Mann-Whitney test, repeated measures analysis of variance with rank transformation (ANOVA) followed by contrast test and multiple linear regression analysis were used. Results: A significant difference was found for the number of microembolic signals in both groups. There were, on average, 89.8 (± 171.4) signals per procedure in the CEA group, while the average in the CAS group was 597.5 (± 343.3) signals per procedure. The average blood flow in the MCA was, in both groups, significantly lower during the stage of protection. Local anesthesia correlated positively (p= .003) with increase in microembolic signals and history of prolonged tobacco use having dropped the addiction for over a year correlated negatively (p= -.014) with the frequency of microembolic signals. Conclusion: Semi-eversion CEA, in light of our TCD findings, evoked a smaller incidence of hyperintense microemboli per procedure than CAS with a distal filter in all the protection stages. The average of the mean blood flow velocity within the MCA has behaved similarly between both groups (CAS and CEA). General anesthesia and the history of tobacco use (as long as the patient had quit for a year or more prior to surgery) were the only two variables in the study that correlated significantly (negatively) with the frequency of microembolic signals / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências
16

Carotid stenosis / Karotisstenos

Johansson, Elias January 2011 (has links)
Carotid stenosis is one of several causes of ischemic stroke and entails a high risk of ischemic stroke recurrence. Removal of a carotid stenosis by carotid endarterectomy results in a risk reduction for ischemic stroke, but the magnitude of risk reduction depends on several factors. If the delay between the last symptom and carotid endarterectomy is less than 2 weeks, the absolute risk reduction is >10%, regardless of age, sex, or if the degree of carotid stenosis is 50–69% or 70–99%. Thus, speed is the key. However, if many patients suffers an ischemic stroke recurrence within the first 2 weeks of the presenting event, an additional benefit is likely be obtained if carotid endarterectomy is performed even earlier than within 2 week after the presenting event. Carotid endarterectomy for asymptomatic carotid stenoses carries a small risk reduction for stroke. Screening for asymptomatic carotid stenosis requires a prevalence of >5% in the examined population, i.e., higher than in the general population; however, directed screening in groups with a prevalence of >5% is beneficial. The aims of this thesis were to investigate the length of the delay to carotid endarterectomy, determine the risk of recurrent stroke before carotid endarterectomy, and determine if a calcification in the area of the carotid arteries seen on dental panoramic radiographs is a valid selection method for directed ultrasound screening to detect asymptomatic carotid stenosis. Consecutive patients with a symptomatic carotid stenosis who underwent a preoperative evaluation aimed at carotid endarterectomy at Umeå Stroke Centre between January 1, 2004–March 31, 2006 (n=275) were collected retrospectively and between August 1, 2007–December 31, 2009 (n=230) prospectively. In addition, 117 consecutive persons, all preliminarily eligible for asymptomatic carotid endarterectomy and with a calcification in the area of the carotid arteries seen on panoramic radiographs, were prospectively examined with carotid ultrasound. The median delay between the presenting event and carotid endarterectomy was 11.7 weeks in the first half year of 2004, dropped to 6.9 weeks in the first quarter year of 2006, and had dropped to 3.6 weeks in the second half year of 2009. The risk of ipsilateral ischemic stroke recurrence was 4.8% within 2 days, 7.9% within 1 week, and 11.2% within 2 weeks of the presenting event. For patients with a stroke or transient ischemic attack as the presenting event, this risk was 6.0% within 2 days, 9.7% within 1 week, and 14.3% within 2 weeks of the presenting event. For the 10 patients with a near-occlusion, the risk of ipsilateral ischemic stroke recurrence was 50% at 4 weeks after the presenting event. Among the 117 persons with a calcification in the area of the carotid arteries seen on panoramic radiographs, eight had a 50–99% carotid stenosis, equalling a prevalence of 6.8% (not statistically significantly over the pre-specified 5% threshold). Among men, the prevalence of 50–99% carotid stenosis was 12.5%, which was statistically significantly over the pre-specified 5% threshold. In conclusion: The delay to carotid endarterectomy was longer than 2 weeks. Additional benefit is likely to be gained by performing carotid endarterectomy within a few days of the presenting event instead of at 2 weeks because many patients suffer a stroke recurrence within a few days; speed is indeed the key. The finding that near-occlusion entails an early high risk of stroke recurrence stands in sharp contrast to previous studies; one possible explaination is that this was a high-risk period missed in previous studies. The incidental finding of a calcification in the area of the carotid arteries on a panoramic radiograph is a valid indication for carotid ultrasound screening in men who are otherwise eligible for asymptomatic carotid endarterectomy.
17

Proteína S-100ß do bulbo da jugular interna : um marcador de dano neuronal isquêmico em endarterectomia de carótida com clampeamento temporário

Minuzzi, Rosângela da Rosa January 2009 (has links)
A endarterectomia de carótida tem um papel bem estabelecido na prevenção de AVC ipsilateral em pacientes com mais de 50% de estenose sintomática da artéria carótida interna. No entanto, o dano cerebral isquêmico contribui significativamente para a morbidade e mortalidade perioperatórias aumentadas na endarterectomia de carótida com clampeamento intra-operatório temporário. Portanto a relação entre a gravidade do dano isquêmico neuronal durante o procedimento e o sistema de auto-regulação do funcionamento da relação oferta/consumo de oxigênio cerebral precisa ser explorado. Esta avaliação poderia ser feita usando-se um marcador sensível de estresse hipóxico, tal como a proteína S-100ß, que é liberada das células da astroglia que sofreram dano estrutural, para o interior da circulação sangüínea quando a permeabilidade da barreira hemato-encefálica está alterada. Isto é especialmente verdadeiro porque uma baixa pressão no coto distal ao clampeamento continua a ser o critério principal para shunt, embora ela possa estar normal em 6% a 30% dos pacientes que subseqüentemente desenvolvem sinais neurológicos, e anormal em 3% a 11% daqueles que não desenvolvem sinais de isquemia. Então, faz sentido investigar outros métodos para detectar dano cerebral isquêmico em endarterectomia de carótida, tais como a taxa de extração de oxigênio cerebral (ECO2) para permitir a otimização de variáveis acessíveis à intervenção médica, como: shunt, parâmetros ventilatórios e parâmetros hemodinâmicos. O objetivo deste trabalho foi avaliar a correlação entre um marcador de dano cerebral isquêmico, a proteína S-100ß sérica, com a fração de extração de oxigênio cerebral (ECO2) e com a pressão arterial de dióxido de carbono (PaCO2) em pacientes submetidos à endarterectomia de carótida para estenose sintomática, com clampeamento temporário. Este estudo transversal avaliou 33 pacientes, estado físico II e III e média de idade de 70 ± 8 anos que foram submetidos à anestesia geral endovenosa e inalatória . PaCO2 (mmHg) e % ECO2 foram medidas antes do clampeamento da carótida (T1), 5 minutos após o clampeamento (T2) e 5 minutos após o desclampeamento (T3) a partir de amostras sangüíneas retiradas da veia jugular interna. S-100ß foi determinada nos seguintes momentos: antes do clampeamento da carótida (T1), imediatamente antes do desclampeamento (T2) e 6 horas após o desclampeamento (T3). O tempo médio de isquemia cerebral foi de 16 minutos [(IQ25-75) 11,05 a 19,00]. Os coeficientes de correlação de Spearman (rs) para a relação entre os níveis de S-100β em 6 horas após a cirurgia e os níveis de ECO2 e PaCO2 durante o período do estudo foram rs = 0,59 (P = 0,00) e rs = -0,36 (P = 0,00) respectivamente. Em conclusão, os presentes achados sugerem que o dano neuronal isquêmico avaliado pela ECO2 durante o período isquêmico podem predizer um aumento de S-100ß. Contudo, futuros estudos são necessários para determinar o impacto clínico de tais achados. / Carotid endarterectomy (CED) is a well established procedure to prevent ipsilateral stroke in patients with more than 50% symptomatic internal carotid artery (ICA) stenosis. However, ischemic brain injury persists as a significant contributing factor to increased perioperative morbidity and mortality in carotid endarterectomy with temporary intraoperative clamping. Hence, the relationship between the severity of neuronal ischemic damage during carotid endarterectomy (CED) and the autoregulation system of the functioning brain oxygen supply/consumption ratio needs to be further explored. This appraisal could be made using a sensitive marker of hypoxic stress, such as S-100ß released into de bloodstream when structural damage to astroglial cells alter the permeability of the blood-brain barrier. This methodological resource can be valuable since a low stump pressure is generally the main criterion for shunting, although normal in about 6-30% of patients who subsequently develop neurological signs and abnormal in 3-11% in those without signs of ischemia. Thus, it makes sense to search for additional subsidies to detect ischemic brain damage during carotid endarterectomy, such as the rate of brain oxygen extraction (ECO2). This earlier accessible variable at low cost could help medical decision-making such as shunt or changes in hemodynamic and ventilatory parameters. The aim of this study was, therefore, assess the correlation between a marker of neuronal ischemic damage, serum S-100ß, and brain oxygen extraction fraction (ECO2) and PaCO2 (arterial carbon dioxide tension) in patients undergoing carotid endarterectomy for symptomatic stenosis with temporary clamping. This cross-sectional study assessed 33 patients, physical status II-III, and mean age of 70 ± 8 years, who undergoing intravenous general anesthesia. PaCO2 (mmHg) and %ECO2 were measured prior to carotid clamping (T1), 5 min after carotid clamping (T2) and 5 min after carotid unclamping (T3) with blood drawn from the internal jugular vein. Serum S-100β was determined at T1 - prior to carotid clamping, T2 - immediately before carotid unclamping, and T3 - 6 h after carotid unclamping. The median time of brain ischemia was 16 min [(IQ25-75) 11.05 to 19.00]. Spearman correlation coefficients (rs) for the relationship between S-100ß level at 6 h after surgery and PaCO2 and ECO2 levels during the study period were rs = -0.36 (P < 0.01) and rs = 0.59 (P < 0.01), respectively. To conclude, the present findings suggest that brain ischemic neural damage monitored by ECO2 during the ischemic time may predict an increase in S-100ß. Further studies are warranted to assess the clinical impact of these results.
18

Proteína S-100ß do bulbo da jugular interna : um marcador de dano neuronal isquêmico em endarterectomia de carótida com clampeamento temporário

Minuzzi, Rosângela da Rosa January 2009 (has links)
A endarterectomia de carótida tem um papel bem estabelecido na prevenção de AVC ipsilateral em pacientes com mais de 50% de estenose sintomática da artéria carótida interna. No entanto, o dano cerebral isquêmico contribui significativamente para a morbidade e mortalidade perioperatórias aumentadas na endarterectomia de carótida com clampeamento intra-operatório temporário. Portanto a relação entre a gravidade do dano isquêmico neuronal durante o procedimento e o sistema de auto-regulação do funcionamento da relação oferta/consumo de oxigênio cerebral precisa ser explorado. Esta avaliação poderia ser feita usando-se um marcador sensível de estresse hipóxico, tal como a proteína S-100ß, que é liberada das células da astroglia que sofreram dano estrutural, para o interior da circulação sangüínea quando a permeabilidade da barreira hemato-encefálica está alterada. Isto é especialmente verdadeiro porque uma baixa pressão no coto distal ao clampeamento continua a ser o critério principal para shunt, embora ela possa estar normal em 6% a 30% dos pacientes que subseqüentemente desenvolvem sinais neurológicos, e anormal em 3% a 11% daqueles que não desenvolvem sinais de isquemia. Então, faz sentido investigar outros métodos para detectar dano cerebral isquêmico em endarterectomia de carótida, tais como a taxa de extração de oxigênio cerebral (ECO2) para permitir a otimização de variáveis acessíveis à intervenção médica, como: shunt, parâmetros ventilatórios e parâmetros hemodinâmicos. O objetivo deste trabalho foi avaliar a correlação entre um marcador de dano cerebral isquêmico, a proteína S-100ß sérica, com a fração de extração de oxigênio cerebral (ECO2) e com a pressão arterial de dióxido de carbono (PaCO2) em pacientes submetidos à endarterectomia de carótida para estenose sintomática, com clampeamento temporário. Este estudo transversal avaliou 33 pacientes, estado físico II e III e média de idade de 70 ± 8 anos que foram submetidos à anestesia geral endovenosa e inalatória . PaCO2 (mmHg) e % ECO2 foram medidas antes do clampeamento da carótida (T1), 5 minutos após o clampeamento (T2) e 5 minutos após o desclampeamento (T3) a partir de amostras sangüíneas retiradas da veia jugular interna. S-100ß foi determinada nos seguintes momentos: antes do clampeamento da carótida (T1), imediatamente antes do desclampeamento (T2) e 6 horas após o desclampeamento (T3). O tempo médio de isquemia cerebral foi de 16 minutos [(IQ25-75) 11,05 a 19,00]. Os coeficientes de correlação de Spearman (rs) para a relação entre os níveis de S-100β em 6 horas após a cirurgia e os níveis de ECO2 e PaCO2 durante o período do estudo foram rs = 0,59 (P = 0,00) e rs = -0,36 (P = 0,00) respectivamente. Em conclusão, os presentes achados sugerem que o dano neuronal isquêmico avaliado pela ECO2 durante o período isquêmico podem predizer um aumento de S-100ß. Contudo, futuros estudos são necessários para determinar o impacto clínico de tais achados. / Carotid endarterectomy (CED) is a well established procedure to prevent ipsilateral stroke in patients with more than 50% symptomatic internal carotid artery (ICA) stenosis. However, ischemic brain injury persists as a significant contributing factor to increased perioperative morbidity and mortality in carotid endarterectomy with temporary intraoperative clamping. Hence, the relationship between the severity of neuronal ischemic damage during carotid endarterectomy (CED) and the autoregulation system of the functioning brain oxygen supply/consumption ratio needs to be further explored. This appraisal could be made using a sensitive marker of hypoxic stress, such as S-100ß released into de bloodstream when structural damage to astroglial cells alter the permeability of the blood-brain barrier. This methodological resource can be valuable since a low stump pressure is generally the main criterion for shunting, although normal in about 6-30% of patients who subsequently develop neurological signs and abnormal in 3-11% in those without signs of ischemia. Thus, it makes sense to search for additional subsidies to detect ischemic brain damage during carotid endarterectomy, such as the rate of brain oxygen extraction (ECO2). This earlier accessible variable at low cost could help medical decision-making such as shunt or changes in hemodynamic and ventilatory parameters. The aim of this study was, therefore, assess the correlation between a marker of neuronal ischemic damage, serum S-100ß, and brain oxygen extraction fraction (ECO2) and PaCO2 (arterial carbon dioxide tension) in patients undergoing carotid endarterectomy for symptomatic stenosis with temporary clamping. This cross-sectional study assessed 33 patients, physical status II-III, and mean age of 70 ± 8 years, who undergoing intravenous general anesthesia. PaCO2 (mmHg) and %ECO2 were measured prior to carotid clamping (T1), 5 min after carotid clamping (T2) and 5 min after carotid unclamping (T3) with blood drawn from the internal jugular vein. Serum S-100β was determined at T1 - prior to carotid clamping, T2 - immediately before carotid unclamping, and T3 - 6 h after carotid unclamping. The median time of brain ischemia was 16 min [(IQ25-75) 11.05 to 19.00]. Spearman correlation coefficients (rs) for the relationship between S-100ß level at 6 h after surgery and PaCO2 and ECO2 levels during the study period were rs = -0.36 (P < 0.01) and rs = 0.59 (P < 0.01), respectively. To conclude, the present findings suggest that brain ischemic neural damage monitored by ECO2 during the ischemic time may predict an increase in S-100ß. Further studies are warranted to assess the clinical impact of these results.
19

Proteína S-100ß do bulbo da jugular interna : um marcador de dano neuronal isquêmico em endarterectomia de carótida com clampeamento temporário

Minuzzi, Rosângela da Rosa January 2009 (has links)
A endarterectomia de carótida tem um papel bem estabelecido na prevenção de AVC ipsilateral em pacientes com mais de 50% de estenose sintomática da artéria carótida interna. No entanto, o dano cerebral isquêmico contribui significativamente para a morbidade e mortalidade perioperatórias aumentadas na endarterectomia de carótida com clampeamento intra-operatório temporário. Portanto a relação entre a gravidade do dano isquêmico neuronal durante o procedimento e o sistema de auto-regulação do funcionamento da relação oferta/consumo de oxigênio cerebral precisa ser explorado. Esta avaliação poderia ser feita usando-se um marcador sensível de estresse hipóxico, tal como a proteína S-100ß, que é liberada das células da astroglia que sofreram dano estrutural, para o interior da circulação sangüínea quando a permeabilidade da barreira hemato-encefálica está alterada. Isto é especialmente verdadeiro porque uma baixa pressão no coto distal ao clampeamento continua a ser o critério principal para shunt, embora ela possa estar normal em 6% a 30% dos pacientes que subseqüentemente desenvolvem sinais neurológicos, e anormal em 3% a 11% daqueles que não desenvolvem sinais de isquemia. Então, faz sentido investigar outros métodos para detectar dano cerebral isquêmico em endarterectomia de carótida, tais como a taxa de extração de oxigênio cerebral (ECO2) para permitir a otimização de variáveis acessíveis à intervenção médica, como: shunt, parâmetros ventilatórios e parâmetros hemodinâmicos. O objetivo deste trabalho foi avaliar a correlação entre um marcador de dano cerebral isquêmico, a proteína S-100ß sérica, com a fração de extração de oxigênio cerebral (ECO2) e com a pressão arterial de dióxido de carbono (PaCO2) em pacientes submetidos à endarterectomia de carótida para estenose sintomática, com clampeamento temporário. Este estudo transversal avaliou 33 pacientes, estado físico II e III e média de idade de 70 ± 8 anos que foram submetidos à anestesia geral endovenosa e inalatória . PaCO2 (mmHg) e % ECO2 foram medidas antes do clampeamento da carótida (T1), 5 minutos após o clampeamento (T2) e 5 minutos após o desclampeamento (T3) a partir de amostras sangüíneas retiradas da veia jugular interna. S-100ß foi determinada nos seguintes momentos: antes do clampeamento da carótida (T1), imediatamente antes do desclampeamento (T2) e 6 horas após o desclampeamento (T3). O tempo médio de isquemia cerebral foi de 16 minutos [(IQ25-75) 11,05 a 19,00]. Os coeficientes de correlação de Spearman (rs) para a relação entre os níveis de S-100β em 6 horas após a cirurgia e os níveis de ECO2 e PaCO2 durante o período do estudo foram rs = 0,59 (P = 0,00) e rs = -0,36 (P = 0,00) respectivamente. Em conclusão, os presentes achados sugerem que o dano neuronal isquêmico avaliado pela ECO2 durante o período isquêmico podem predizer um aumento de S-100ß. Contudo, futuros estudos são necessários para determinar o impacto clínico de tais achados. / Carotid endarterectomy (CED) is a well established procedure to prevent ipsilateral stroke in patients with more than 50% symptomatic internal carotid artery (ICA) stenosis. However, ischemic brain injury persists as a significant contributing factor to increased perioperative morbidity and mortality in carotid endarterectomy with temporary intraoperative clamping. Hence, the relationship between the severity of neuronal ischemic damage during carotid endarterectomy (CED) and the autoregulation system of the functioning brain oxygen supply/consumption ratio needs to be further explored. This appraisal could be made using a sensitive marker of hypoxic stress, such as S-100ß released into de bloodstream when structural damage to astroglial cells alter the permeability of the blood-brain barrier. This methodological resource can be valuable since a low stump pressure is generally the main criterion for shunting, although normal in about 6-30% of patients who subsequently develop neurological signs and abnormal in 3-11% in those without signs of ischemia. Thus, it makes sense to search for additional subsidies to detect ischemic brain damage during carotid endarterectomy, such as the rate of brain oxygen extraction (ECO2). This earlier accessible variable at low cost could help medical decision-making such as shunt or changes in hemodynamic and ventilatory parameters. The aim of this study was, therefore, assess the correlation between a marker of neuronal ischemic damage, serum S-100ß, and brain oxygen extraction fraction (ECO2) and PaCO2 (arterial carbon dioxide tension) in patients undergoing carotid endarterectomy for symptomatic stenosis with temporary clamping. This cross-sectional study assessed 33 patients, physical status II-III, and mean age of 70 ± 8 years, who undergoing intravenous general anesthesia. PaCO2 (mmHg) and %ECO2 were measured prior to carotid clamping (T1), 5 min after carotid clamping (T2) and 5 min after carotid unclamping (T3) with blood drawn from the internal jugular vein. Serum S-100β was determined at T1 - prior to carotid clamping, T2 - immediately before carotid unclamping, and T3 - 6 h after carotid unclamping. The median time of brain ischemia was 16 min [(IQ25-75) 11.05 to 19.00]. Spearman correlation coefficients (rs) for the relationship between S-100ß level at 6 h after surgery and PaCO2 and ECO2 levels during the study period were rs = -0.36 (P < 0.01) and rs = 0.59 (P < 0.01), respectively. To conclude, the present findings suggest that brain ischemic neural damage monitored by ECO2 during the ischemic time may predict an increase in S-100ß. Further studies are warranted to assess the clinical impact of these results.
20

Avaliação da resposta hemodinâmica cerebral através da monitorização com a espectroscopia próxima ao infravermelho (NIRS) em pacientes com doença aterosclerótica submetidos à endarterectomia de carótida = Evaluation of the brain hemodynamic response by means of near-infrared spectroscopy (NIRS) monitoring in atherosclerotic patients who underwent carotid endarterectomy / Evaluation of the brain hemodynamic response by means of near-infrared spectroscopy (NIRS) monitoring in atherosclerotic patients who underwent carotid endarterectomy

Siqueira, Letícia Cristina Dalledone, 1981- 28 August 2018 (has links)
Orientador: Ana Terezinha Guillaumon / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-28T09:17:18Z (GMT). No. of bitstreams: 1 Siqueira_LeticiaCristinaDalledone_M.pdf: 5041737 bytes, checksum: 615b5b4269f2f46490565662d28dfb21 (MD5) Previous issue date: 2015 / Resumo: Introdução: A espectroscopia próxima ao infra-vermelho (NIRS) é uma técnica não invasiva e de baixo custo que detecta as alterações hemodinâmicas teciduais. O NIRS pode monitorar de forma contínua as informações fisiológicas vasculares intracranianas. Por ser portátil, ele pode ser utilizado a beira do leito e no centro cirúrgico. Objetivo: Avaliar o comportamento das possíveis alterações hemodinâmicas cerebrais, durante a endarterectomia, em pacientes com estenoses maiores que 70%, utilizando NIRS. Casuística e métodos: Foram avaliados 10 voluntários portadores de doença carotídea aterosclerótica com indicação de endarterectomia. Após a seleção dos pacientes que responderam um questionário com dados epidemiológicos e informações referentes a presença de comorbidades, a doença foi confirmada por métodos diagnósticos. No procedimento cirúrgico utilizou-se o NIRS para monitorização. Foram avaliadas as variáveis saturação de oxigênio (Sat O2) hemoglobina total (HbT), hemoglobina reduzida (HbR) e hemoglobina oxigenada (HbO) nos três tempos cirúrgicos pré, trans e pós-clampeamento carotídeo. Resultados: Utilizou-se p<0,05 como nivel de significância. A avaliação dos resultados obtidos através das medidas registradas pelo NIRS permite afirmar que as etapas da cirurgia diferem quanto ás variável HbR e SatO2. Durante a etapa do clampeamento, a variável HbR mostra valores mais elevados que nas outras duas etapas da cirurgia. De outra parte, a variável SatO2 mostra redução durante o clampeamento. Conclusão: O NIRS é um método viável e aplicável de monitorização intracerebral, não-invasivo e em tempo real, durante a endarterectomia carotídea, capaz de medir de forma precisa as mudanças das condições hemodinâmicas capilares intra-cerebrais / Abstract: Introduction: Near-infrared spectroscopy (NIRS) is a low-cost, non-invasive technique that detects tissue hemodynamic alterations. It enables continuous monitoring of the intracerebral vascular physiologic information. Due to its portable nature, NIRS may be used beside a bed or in the operating room. Objective: To evaluate the use of NIRS for intra-surgical monitoring of the brain hemodynamic response, during an endarterectomy procedure of the atherosclerotic carotid artery. Casuistry and Methods: 10 patients with atherosclerotic carotid disease and recommended endarterectomy were evaluated. They were identified in a survey which provided epidemiologic data and the presence of comorbidities. Disease was confirmed by diagnostic methods. NRIS monitoring was used during the surgical procedure. Oxygen saturation (O2 Sat), total hemoglobin (THb), reduced hemoglobin (RHb), and oxyhemoglobin (OHb) were the variables analyzed at the three carotid clamp stages: pre-, trans- and post-. Results: A p<0.05 value was considered statistically significant. The results obtained from the NIRS data reveal that the surgical stages differ in relation to the RHb and O2Sat variables. RHb presents higher levels during clamping when compared with the other two surgical stages. On the other hand, O2Sat is decreased during clamping. Conclusion: NIRS is a feasible, realtime and non-invasive intracranial monitoring method, during carotid endarterectomy, which measures accurately and reliably the changes of the intracerebral capillary hemodynamic conditions / Mestrado / Cirurgia / Mestra em Ciências

Page generated in 0.0832 seconds