• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cellular and tissue responses to implant materials : development of a novel organ culture model

Leung, Theresa January 1998 (has links)
No description available.
2

Análise histológica e histomorfométrica da osseointegração de implantes de titânio inseridos na tíbia de ratos Wistar induzidos por ácido zoledrônico e dexametasona / Histologic and histomorphometric analysis of the osseointegration of endosseous implants placed on the tibiae of Wistar rats treated with zoledronic acid and dexamethasone

Oliveira, Marcio Augusto de 03 December 2012 (has links)
A terapia com bisfosfonatos tem sido frequentemente empregada no tratamento de doenças metabólicas do osso e neoplasias malignas. O objetivo deste estudo foi avaliar através de análise histológica e histomorfométrica em cortes não descalcificados, a influência dos bisfosfonatos nitrogenados endovenosos associados ou não a dexametasona sobre a osseointegração de implantes instalados em tíbias de 27 ratos Wistar. Ácido zoledrônico e dexametasona foram administrados por via subcutânea nos animais dos grupos experimentais. Os animais foram acompanhados por 7, 14 e 28 dias. Nossos resultados mostraram que não houve falha na osseointegração em nenhum animal avaliado e que não foram observadas diferenças estatisticamente significantes entre os 3 grupos com relação à quantidade de contato entre osso e implante e presença de osso em áreas pré determinadas, nos tempos observados. No entanto nossas observações histológicas revelaram que nos animais tratados com bisfosfonatos associados ou não com dexametasona, aos 14 e 28 dias após a colocação do implante não ocorreu o fenômeno de remodelação da cortical óssea, ao contrário do grupo controle. Concluímos que a terapia com bisfosfonatos associada ou não com dexametasona não impediu a osseointegração do implante com o osso mas inibiu severamente a remodelação da cortical óssea pré existente. / Bisphosphonate therapy has been often employed in the treatment of metabolic bone diseases and malignancies. The aim of this study was to evaluate through histological and histomorphometric analysis the influence of intravenous nitrogen-containing bisphosphonates alone or combined with dexamethasone on the osseointegration of implants placed in the tibia of 27 male Wistar rats in non decalcified samples. Zoledronic acid and dexamethasone were administered through sub cutaneous injections. The animals were followed through 7, 14, and 28 days. Our results showed that there was no failure in osseointegration in any animal, and that there were no statistically significant differences among the 3 groups regarding the amount of bone-implant contact and peri-implant bone density in predetermined areas. However our histological observations revealed that animals treated with bisphosphonates, associated or not with dexamethasone, at 14 and 28 days after implant placement has not occurred the phenomenon of cortical bone remodeling, unlike control group. We conclude that bisphosphonate therapy associated or not with dexamethasone did not prevent osseointegration of the implants but severely inhibited the remodeling of pre-existing cortical bone.
3

Análise histológica e histomorfométrica da osseointegração de implantes de titânio inseridos na tíbia de ratos Wistar induzidos por ácido zoledrônico e dexametasona / Histologic and histomorphometric analysis of the osseointegration of endosseous implants placed on the tibiae of Wistar rats treated with zoledronic acid and dexamethasone

Marcio Augusto de Oliveira 03 December 2012 (has links)
A terapia com bisfosfonatos tem sido frequentemente empregada no tratamento de doenças metabólicas do osso e neoplasias malignas. O objetivo deste estudo foi avaliar através de análise histológica e histomorfométrica em cortes não descalcificados, a influência dos bisfosfonatos nitrogenados endovenosos associados ou não a dexametasona sobre a osseointegração de implantes instalados em tíbias de 27 ratos Wistar. Ácido zoledrônico e dexametasona foram administrados por via subcutânea nos animais dos grupos experimentais. Os animais foram acompanhados por 7, 14 e 28 dias. Nossos resultados mostraram que não houve falha na osseointegração em nenhum animal avaliado e que não foram observadas diferenças estatisticamente significantes entre os 3 grupos com relação à quantidade de contato entre osso e implante e presença de osso em áreas pré determinadas, nos tempos observados. No entanto nossas observações histológicas revelaram que nos animais tratados com bisfosfonatos associados ou não com dexametasona, aos 14 e 28 dias após a colocação do implante não ocorreu o fenômeno de remodelação da cortical óssea, ao contrário do grupo controle. Concluímos que a terapia com bisfosfonatos associada ou não com dexametasona não impediu a osseointegração do implante com o osso mas inibiu severamente a remodelação da cortical óssea pré existente. / Bisphosphonate therapy has been often employed in the treatment of metabolic bone diseases and malignancies. The aim of this study was to evaluate through histological and histomorphometric analysis the influence of intravenous nitrogen-containing bisphosphonates alone or combined with dexamethasone on the osseointegration of implants placed in the tibia of 27 male Wistar rats in non decalcified samples. Zoledronic acid and dexamethasone were administered through sub cutaneous injections. The animals were followed through 7, 14, and 28 days. Our results showed that there was no failure in osseointegration in any animal, and that there were no statistically significant differences among the 3 groups regarding the amount of bone-implant contact and peri-implant bone density in predetermined areas. However our histological observations revealed that animals treated with bisphosphonates, associated or not with dexamethasone, at 14 and 28 days after implant placement has not occurred the phenomenon of cortical bone remodeling, unlike control group. We conclude that bisphosphonate therapy associated or not with dexamethasone did not prevent osseointegration of the implants but severely inhibited the remodeling of pre-existing cortical bone.
4

"Avaliação da densidade ótica perimplantar cervical em controle longitudinal de implantes com função oclusal imediata em maxila" / Evaluation of the cervical perimplantar optical density in a longitudinal control of implants with immediate occlusion function in maxilla

Hayek, Jorge Elie 11 October 2005 (has links)
A proposta neste estudo foi avaliar as alterações da densidade ótica do osso alveolar perimplantar cervical em controle longitudinal, por meio de radiografias periapicais digitalizadas de dez pacientes, nos quais foram instalados seis implantes na maxila submetidos à função oclusal imediata, mediante a instalação de uma prótese fixa 24 horas após a cirurgia. Todos os pacientes foram avaliados clinicamente, com exames da análise da freqüência de ressonância, além de controle radiográfico. Foi utilizada a técnica radiográfica intrabucal do parale lismo, com cone longo, sendo que o feixe de raios X incidiu perpendicularmente ao longo eixo do implante. Os controles radiográficos foram realizados na instalação da prótese, após 6 meses e após 12 meses. As radiografias obtidas foram então capturadas por uma câmera de vídeo (preto e branco) por meio de um microscópio ótico (40 vezes de aumento). Devido à ampliação utilizada, os implantes tiveram suas imagens digitalizadas em 2 etapas (metade direita e metade esquerda), sendo consideradas como amostras independentes. Após a sobreposição de um gabarito sobre a imagem, com a finalidade padronizar as áreas a serem estudadas, foram analisadas as densidades óticas na área de interesse osso + implante e na área de controle implante (onde não é esperada alteração) por meio do software ImageLab. Para a correção de possíveis variações na densidade da radiografia e projeção geométrica oriundas da metodologia empregada, foi utilizada uma equação matemática para validar a análise dos dados obtidos. Os resultados mostraram que ocorreu variação percentual da densidade ótica na área de interesse (osso + implante) nos primeiros seis meses (T2) com diminuição de aproximadamente 5% para o lado direito e diminuição de aproximadamente 6% para o lado esquerdo em relação às radiografias iniciais (T1) e após doze meses, a diminuição da densidade ótica estabilizou-se, não sendo encontradas alterações estatisticamente significantes em relação ao período correspondente entre T2 (seis meses) e T3 (doze meses). Os resultados da análise digital das radiografias periapicais demonstraram coincidência com os resultados da análise da freqüência de ressonância e exame clínico dos implantes e demonstraram um aspecto compatível com o sucesso dos implantes osteointegrados com função imediata na maxila. / The aim in this study was the evaluation of the variations of the perimplantar optical bone density at the cervical region in a longitudinal control, by the use of digitized radiographs of ten patients, who received six implants installed in the maxilla and submitted to immediate occlusion function, through fixed prosthesis installed 24 hours after the surgery. All the patients were observed in clinical control, with resonance frequency analysis and also radiographic control. It was performed a intraoral radiograph using the paralleling technique, with the long cone and the beam of x-ray aimed perpendicular to the long axis of the implant. The radiographic controls were done at the time of the installation of the prosthesis, after six months and after twelve months after the first control. The obtained radiographs were captured by a black and white video camera by an optical microscope (40 times of magnification). Due to the utilized magnification, the implants have their images digitized in two steps: half right and half left, and they were considered as independent samples. After the superimposition of a standardized pattern, to help the standardization of the areas of the study, it was analyzed the optical density at the areas of interest bone + implant and at areas of control bone (where it is not hope changes) through the software ImageLab. To correct possible variations of the effect of the absence of standardization of the geometric projection and the radiographic density, it was realized a mathematic equation and it was obtained a correction factor of density in order to compensate. The results sho wed that there were percentage variation of the optical density at the area of interest (bone + implant) at six months (T2) showed a decreased of about 5% for the right side and showed a decreased of about 6% for the left side when analyzed the first control and after twelve months no significant statistical difference was observed between the T2 period (six months) and T3 period (twelve months). The results of digital analysis from the intraoral radiographs showed as the same as the results of resonance frequency analysis and the clinic examination of the implants and showed a success of implants installed in the maxilla with immediate occlusion function.
5

"Avaliação da densidade ótica perimplantar cervical em controle longitudinal de implantes com função oclusal imediata em maxila" / Evaluation of the cervical perimplantar optical density in a longitudinal control of implants with immediate occlusion function in maxilla

Jorge Elie Hayek 11 October 2005 (has links)
A proposta neste estudo foi avaliar as alterações da densidade ótica do osso alveolar perimplantar cervical em controle longitudinal, por meio de radiografias periapicais digitalizadas de dez pacientes, nos quais foram instalados seis implantes na maxila submetidos à função oclusal imediata, mediante a instalação de uma prótese fixa 24 horas após a cirurgia. Todos os pacientes foram avaliados clinicamente, com exames da análise da freqüência de ressonância, além de controle radiográfico. Foi utilizada a técnica radiográfica intrabucal do parale lismo, com cone longo, sendo que o feixe de raios X incidiu perpendicularmente ao longo eixo do implante. Os controles radiográficos foram realizados na instalação da prótese, após 6 meses e após 12 meses. As radiografias obtidas foram então capturadas por uma câmera de vídeo (preto e branco) por meio de um microscópio ótico (40 vezes de aumento). Devido à ampliação utilizada, os implantes tiveram suas imagens digitalizadas em 2 etapas (metade direita e metade esquerda), sendo consideradas como amostras independentes. Após a sobreposição de um gabarito sobre a imagem, com a finalidade padronizar as áreas a serem estudadas, foram analisadas as densidades óticas na área de interesse osso + implante e na área de controle implante (onde não é esperada alteração) por meio do software ImageLab. Para a correção de possíveis variações na densidade da radiografia e projeção geométrica oriundas da metodologia empregada, foi utilizada uma equação matemática para validar a análise dos dados obtidos. Os resultados mostraram que ocorreu variação percentual da densidade ótica na área de interesse (osso + implante) nos primeiros seis meses (T2) com diminuição de aproximadamente 5% para o lado direito e diminuição de aproximadamente 6% para o lado esquerdo em relação às radiografias iniciais (T1) e após doze meses, a diminuição da densidade ótica estabilizou-se, não sendo encontradas alterações estatisticamente significantes em relação ao período correspondente entre T2 (seis meses) e T3 (doze meses). Os resultados da análise digital das radiografias periapicais demonstraram coincidência com os resultados da análise da freqüência de ressonância e exame clínico dos implantes e demonstraram um aspecto compatível com o sucesso dos implantes osteointegrados com função imediata na maxila. / The aim in this study was the evaluation of the variations of the perimplantar optical bone density at the cervical region in a longitudinal control, by the use of digitized radiographs of ten patients, who received six implants installed in the maxilla and submitted to immediate occlusion function, through fixed prosthesis installed 24 hours after the surgery. All the patients were observed in clinical control, with resonance frequency analysis and also radiographic control. It was performed a intraoral radiograph using the paralleling technique, with the long cone and the beam of x-ray aimed perpendicular to the long axis of the implant. The radiographic controls were done at the time of the installation of the prosthesis, after six months and after twelve months after the first control. The obtained radiographs were captured by a black and white video camera by an optical microscope (40 times of magnification). Due to the utilized magnification, the implants have their images digitized in two steps: half right and half left, and they were considered as independent samples. After the superimposition of a standardized pattern, to help the standardization of the areas of the study, it was analyzed the optical density at the areas of interest bone + implant and at areas of control bone (where it is not hope changes) through the software ImageLab. To correct possible variations of the effect of the absence of standardization of the geometric projection and the radiographic density, it was realized a mathematic equation and it was obtained a correction factor of density in order to compensate. The results sho wed that there were percentage variation of the optical density at the area of interest (bone + implant) at six months (T2) showed a decreased of about 5% for the right side and showed a decreased of about 6% for the left side when analyzed the first control and after twelve months no significant statistical difference was observed between the T2 period (six months) and T3 period (twelve months). The results of digital analysis from the intraoral radiographs showed as the same as the results of resonance frequency analysis and the clinic examination of the implants and showed a success of implants installed in the maxilla with immediate occlusion function.
6

Darstellbarkeit von Knochenstrukturen und enossalen Implantaten mit der Flächendetektor-Volumencomputertomographie und mit konventionellen radiologischen Verfahren - Ein Methodenvergleich / Radiologic representation of bone structures and endosseous implants using flat-panel volume computed tomography and conventional radiological techniques - A comparison of methods -

Jarnot, Lena 25 January 2011 (has links)
Ziel: Die Grundlage einer erfolgreichen Insertion dentaler Implantate ist neben dem klinischen Befund die adäquate radiologische Darstellung des geplanten Insertionsortes. Ziel dieser Studie war die Evaluation der Darstellbarkeit von enossalen Implantaten und benachbarten Strukturen mit der Flächendetektor- Volumencomputertomographie (fpVCT) im Vergleich zu derzeit klinisch anwendbaren radiologischen Verfahren in der Zahnmedizin. Methodik: Es wurden insgesamt 14 in Schweinekieferproben inserierte enossale Implantate und die umgebenden Strukturen mit einem Prototyp eines fpVCT untersucht. Die erhobenen Befunde wurden mit intraoralem Zahnfilm (ZF), Orthopantomographie (OPG) und Digitaler Volumentomographie (DVT) verglichen. Ergebnisse: Bei der Erhebung der Daten waren die 3D-Verfahren den 2D-Verfahren aufgrund der überlagerungsfreien Darstellung deutlich überlegen. Die Implantate und periimplantären anatomischen Strukturen, nebst Knochen- und Implantatdefekten und Fremdmaterial, ließen sich mit der fpVCT adäquat detektieren. Die Knochen- und Implantatdefekte konnten hinsichtlich ihrer genauen Lokalisation, Größendimension und Beziehung zu umliegenden Strukturen sehr detailliert beschrieben werden. Differenzierte Aussagen über Art, Anzahl und Größe verschiedener Fremdmaterialien waren möglich. Distanzmessungen ließen sich präzise ausführen. Die genaue Beurteilung von Zahnschmelz, Dentin, Pulpa und dem Parodontalspalt war möglich. Gegenüber in der Klinik etablierten DVT kann bei Verwendung von Flachbilddetekoren zur computertomographischen Bildgebung eine deutlich höhere räumliche Auflösung bis zu 200 μm (bei 10% MTF) erreicht werden. Der Zahnfilm hingegen ermöglicht durch seine hohe Ortsauflösung ebenso eine präzise Darstellung im Mikrometerbereich, stellt nachteilig jedoch wie ein OPG zweidimensionale Summationsdatenbilder dar. Sowohl Zahnfilm als auch OPG gehen vorteilig mit einer deutlich geringeren Strahlenbelastung für den Patienten bei deutlich höherer Verfügbarkeit einher. Im Vergleich von DVT und fpVCT kommt es bei der fpVCT zu geringeren Einschränkungen der Bildauswertung durch Streustrahlenartefakte. Allerdings ist derzeit aufgrund fehlender lokaler Strahlenapplikation eine klinische Anwendung noch nicht möglich. Schlussfolgerung: Die vorliegende Studie zeigt, dass die fpVCT die präzise zerstörungsfreie dreidimensionale Darstellung von Zahnimplantaten und periimplantären Strukturen ermöglicht.

Page generated in 0.0501 seconds