Spelling suggestions: "subject:"energia elétrica - proteção."" "subject:"energia elétrica - roteção.""
1 |
Sistema simulador para treinamento presencial e a distância de operação da proteção de sistemas elétricosBezerra, Hamurabi 11 1900 (has links)
BEZERRA, H. Sistema simulador para treinamento presencial e a distância de operação da proteção de sistemas elétricos. 2008. 106 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2017-01-10T11:48:44Z
No. of bitstreams: 1
2008_dis_hbezerra.pdf: 3224412 bytes, checksum: b21e69e2e4e62493e20b0b25a734cd84 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2017-01-18T18:28:53Z (GMT) No. of bitstreams: 1
2008_dis_hbezerra.pdf: 3224412 bytes, checksum: b21e69e2e4e62493e20b0b25a734cd84 (MD5) / Made available in DSpace on 2017-01-18T18:28:53Z (GMT). No. of bitstreams: 1
2008_dis_hbezerra.pdf: 3224412 bytes, checksum: b21e69e2e4e62493e20b0b25a734cd84 (MD5)
Previous issue date: 2008-11 / The area of electrical power systems worldwide, particularly in developing countries
like Brazil, has expressive importance because it is the basic input to industrial production.
The new institutional model of the Brazilian electrical power sector has demanded greater
competitiveness and larger amount of investment, which brings encouragement to the training
of skilled people for current and future demands, in order to make possible the adequacy of
existing methods and concepts to new operational and commercial technical challenges. The
human resources management policies prevailing in the electricity utility companies have
caused difficulties in recent years for the release of staff to attend training courses. In order to
keep up the qualification and training activities, traditionally carried out in presence courses,
the Virtual Learning Environments (AVA), such as Teleduc, Moodle and AulaNet, have been
continually developed, tested and implemented for courses at distance. This dissertation
presents a system designed for present and at distance training courses for professionals in the
area of protection of electrical power systems. The tool has been developed in the Teleduc
environment, and it offers modules with theory contents in the specific area and a power
system simulator that can represent practical situations, designed for training engineers and
technicians of the electricity sector. The integration of the simulator into the Teleduc interface
for remote and shared operation represents a breakthrough in the teaching-learning process of
technological education and vocational at distance. / A área da energia elétrica ocupa no mundo moderno e, particularmente, nos países em
desenvolvimento como o Brasil expressivo destaque, por se tratar de insumo básico ao
desenvolvimento do país. O novo modelo institucional do setor elétrico brasileiro vem
exigindo maior competitividade e maior quantidade de investimentos, o que incentiva à
formação de pessoas qualificadas para demandas atuais e futuras, de forma a tornar possível a
adequação de métodos e conceitos existentes aos novos desafios técnicos, operacionais e
comerciais na área. A política de racionalização da gestão de recursos humanos das empresas
concessionárias de energia elétrica provocou nos últimos anos dificuldades de liberação de
pessoal para participar de cursos de capacitação. Com o objetivo de dar suporte às atividades
de formação e treinamento, antes tradicionalmente presenciais, Ambientes Virtuais de
Aprendizagem (AVA), tais como Teleduc, Moodle e AulaNet, vêm sendo continuamente
desenvolvidos, testados e aplicados em cursos à distância. Este trabalho apresenta um sistema
desenvolvido para treinamento presencial e a distância de profissionais da área de operação e
proteção de sistemas elétricos de potência. A ferramenta proposta desenvolvida inicialmente
para o ambiente Teleduc oferece módulos com conteúdo de formação teórica no domínio
específico e um simulador capaz de representar situações realísticas, projetado para o
treinamento de engenheiros e técnicos do setor elétrico. A integração do simulador à interface
do Teleduc para operação remota e compartilhada representa um avanço do processo ensinoaprendizagem
do ensino tecnológico e profissional à distância.
|
2 |
Limitador de corrente supercondutor resistivo monofasico : projeto, construção e ensaioHomrich, Roberto Petry 29 July 2018 (has links)
Orientador : Ernesto Ruppert Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:02:12Z (GMT). No. of bitstreams: 1
Homrich_RobertoPetry_D.pdf: 4872054 bytes, checksum: 4d50cf9f2e5b10f0f9c7b1b92bc88613 (MD5)
Previous issue date: 2001 / Doutorado
|
3 |
Modelagem dinâmica de transformadores de corrente para uso em estudos de qualidade da energia e proteção do sistema elétrico /Borges, Fernando de Almeida. January 2014 (has links)
Orientador: José Alfredo Covolan Ulson / Banca: Rogério Andrade Faluzino / Banca: André Luiz Andreoli / Resumo: Os sistemas de proteção, medição e controle das concessionárias de energia elétrica utilizam transdutores eletromagnéticos de tensão e corrente para adequar as grandezas elétrica de interesse em níveis aceitáveis e necessários para relés de proteção e medidores de energia em geral. A não linearidade da corrente e a presença de frequências da fundamental provenientes de transitórios motivaram esse estudo, o qual buscou o entendimento e modelagem da função de transferência entre as correntes secundárias e primárias. Partindo do levantamento de dados em ensaios de laboratório de um transformador de corrente determinou-se a matriz admitância proposta, como modelo, em função da frequência e em seguida a função de transferência também como função da frequência utilizando o Algoritmo "Vector Fitting". Como resultado obteve-se uma função analítica que foi utilizada na estimação de correntes secundárias quando da aplicação de correntes primárias com frequências fundamental e múltiplas. O trablaho teve um resultado positivo em relação ao seu objetivo promovendo o levantamento do comportamento da relação entre as correntes primária e secundária e mostrando um método factível para a modelagem da resposta dos transformadores de corrente como função de frequência / Abstract: Protection systems, measurements and control of electric utilitiesuse electromagnetic transducers for voltage and current to match the electrical quantities at acceptable levels of interest and necessary for protection relays and power meters in general. The nonlinearity of the current and the presence of frequencies different from fundamental one arising from electrical transients motivated this study which sought the understanding and modeling of the transfer function between the primary and secondary currents. Based on the survey data in laboratory testing for a current transformer, admittance matrix model proposed as a function of frequency was determined, and then the transfer function also a function of frequency using Algorithm "Vector Fitting". As a result there was obtained and analytic function that was used in the estimation of secondary currents when applying primary currents at fundamental and multiple frequencies. The work had had a positive result in relation to its objective by promoting the survey of the behavior of the relationship between the primary and secondary currents and showing a feasible approach for modeling the response of Current Transformers as a function of frequency / Mestre
|
4 |
Modelagem dinâmica de transformadores de corrente para uso em estudos de qualidade da energia e proteção do sistema elétricoBorges, Fernando de Almeida [UNESP] 27 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:34Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-01-27Bitstream added on 2014-06-13T20:29:08Z : No. of bitstreams: 1
000741718.pdf: 1195293 bytes, checksum: 25768d5d0666ab49aa2c8ffee3482075 (MD5) / Os sistemas de proteção, medição e controle das concessionárias de energia elétrica utilizam transdutores eletromagnéticos de tensão e corrente para adequar as grandezas elétrica de interesse em níveis aceitáveis e necessários para relés de proteção e medidores de energia em geral. A não linearidade da corrente e a presença de frequências da fundamental provenientes de transitórios motivaram esse estudo, o qual buscou o entendimento e modelagem da função de transferência entre as correntes secundárias e primárias. Partindo do levantamento de dados em ensaios de laboratório de um transformador de corrente determinou-se a matriz admitância proposta, como modelo, em função da frequência e em seguida a função de transferência também como função da frequência utilizando o Algoritmo Vector Fitting. Como resultado obteve-se uma função analítica que foi utilizada na estimação de correntes secundárias quando da aplicação de correntes primárias com frequências fundamental e múltiplas. O trablaho teve um resultado positivo em relação ao seu objetivo promovendo o levantamento do comportamento da relação entre as correntes primária e secundária e mostrando um método factível para a modelagem da resposta dos transformadores de corrente como função de frequência / Protection systems, measurements and control of electric utilitiesuse electromagnetic transducers for voltage and current to match the electrical quantities at acceptable levels of interest and necessary for protection relays and power meters in general. The nonlinearity of the current and the presence of frequencies different from fundamental one arising from electrical transients motivated this study which sought the understanding and modeling of the transfer function between the primary and secondary currents. Based on the survey data in laboratory testing for a current transformer, admittance matrix model proposed as a function of frequency was determined, and then the transfer function also a function of frequency using Algorithm Vector Fitting. As a result there was obtained and analytic function that was used in the estimation of secondary currents when applying primary currents at fundamental and multiple frequencies. The work had had a positive result in relation to its objective by promoting the survey of the behavior of the relationship between the primary and secondary currents and showing a feasible approach for modeling the response of Current Transformers as a function of frequency
|
5 |
Desenvolvimento de um sistema para detecção de falhas de alta impedancia em redes de distribuiçãoJota, Patricia Romeiro da Silva 31 May 1996 (has links)
Orientador: Anesio dos Santos Jr / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-21T11:41:43Z (GMT). No. of bitstreams: 1
Jota_PatriciaRomeirodaSilva_D.pdf: 9312605 bytes, checksum: d193b1ca7fd04de6a0be95f4bf346b52 (MD5)
Previous issue date: 1996 / Resumo: Nesta tese, apresenta-se desenvolvimento de uma metodologia para detecção de falhas de alta impedância em Redes de Distribuição Radial. As técnicas empregadas se baseiam na resposta do alimentador a um impulso de tensão injetado periodicamente na saída da subestação. Esta resposta é armazenada e comparada com um banco de dados previamente construído. Este banco contém as respostas do alimentador para configurações normais de operação. Considera-se que o alimentador está operando em condição faltosa toda vez que a sua resposta não coincidir com as respostas armazenadas no banco de dados. Três técnicas distintas foram implementadas e testadas utilizando dados medidos em um alimentador real da concessionária CEMIG, na cidade de Caratinga, MG... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: In this thesis, the development of a methodology for detection of High Impedance Faults in primary distribution feeders is presented. The technique used is based on the feeder response to a short pulse signal periodicaly injected at the substation outlet. The response to each pulse is compared to the ones previously stored in a database. The database contains the feeder response to the known normal operating configurations. It is assumed that if the response does not coincide with any of the stored responses, then the feeder is operating in a faulty condition. Three different techniques have been implemented and tested using data collected from a real feeder of Campanhia Energetica de Minas Gerais (CEMIG), at Caratinga city, State of Minas Gerais (MG), Brazil... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Engenharia Elétrica
|
6 |
Limitador de corrente eletrica monofasico resistivo supercondutor de alta temperatura critica / Single phase resistive high critical temperature superconducting fault current limiterFreitas, Rafael Cassiolato de 13 August 2018 (has links)
Orientadores: Ernesto Ruppert Filho, Carlos Alberto Baldan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T08:37:22Z (GMT). No. of bitstreams: 1
Freitas_RafaelCassiolatode_M.pdf: 4732668 bytes, checksum: 0819e8d6aca546a3c44b407acd86b0a9 (MD5)
Previous issue date: 2008 / Resumo: O crescimento da demanda de energia elétrica nos centros urbanos e industriais tem levado à necessidade de expansão dos sistemas de energia elétrica o que tem causado aumento nos níveis de curto-circuito, atingindo o limite da capacidade dos sistemas de proteção existentes exigindo sua substituição por outros de maior capacidade. Nessa situação nem sempre a recapacitação dos sistemas de proteção resolve o problema sendo necessário duplicar circuitos. Para postergar investimentos ou para funcionar na rede juntamente com o disjuntor ou ainda, para proteger os circuitos existentes quando conectados a geradores distribuídos, os limitadores de corrente instalados em série com os disjuntores atuais permitem limitar a corrente de falta, principalmente nos primeiros 100ms até a atuação do sistema de proteção. Dentre os diversos tipos de dispositivos limitadores de corrente elétrica existentes no mercado e também ainda em pesquisa
atualmente, os construídos a partir de materiais supercondutores possuem a vantagem de
proporcionar limitação de corrente elétrica praticamente instantânea causando mínima
interferência no funcionamento normal dos sistemas de energia elétrica. Neste trabalho foram
estudadas diversas configurações de limitadores de corrente elétrica utilizando fitas de materiais
cerâmicos supercondutores de alta temperatura crítica (HTS), de modo especial os limitadores
resistivos em forma de bobinas helicoidais enroladas com fita supercondutora BSCCO. Foi
desenvolvida metodologia para o cálculo eletromagnético, projeto, construção e ensaio das
bobinas supercondutoras do limitador de corrente, bem como se procurou caracterizar
eletricamente a fita HTS sob influência de campo magnético externo com o objetivo de
determinar as condições de corrente elétrica e de campo magnético sobre ela aplicado para a
transição do estado supercondutor para o estado condutor normal do material ("quench"). Ao
final do trabalho foram construídos e ensaiados dois protótipos limitadores de corrente elétrica
supercondutores mostrando que, apesar da fita HTS de BSCCO ainda não possuir características
adequadas para aplicação em limitadores de corrente, com a esperada evolução destes materiais
já existe disponível a técnica para projetá-los e construí-los. / Abstract: The growth in demand of electric energy in urban and industrial centers has lead to the need of expansion of the electrical systems which has caused increase in short circuit levels, reaching the limit capacity of the existing protection systems requiring its replacement by others of greater capacity. In these situations the upgrade of protection systems does not always solve the problem being necessary the circuit's duplication. To postpone investments, to operate together in the electrical system with the circuit breakers or even to protect the existing circuits when connected to distributed generators, fault current limiters should be installed in series with the circuit breakers allowing to limit fault currents, specially in the first 100m until the protection system is triggered. Among the many different types of fault current limiter devices existing in the market and which are under development, the ones made of superconducting materials have the
advantage of providing practically instantaneous fault current limitation causing minimum
interference in the normal operation of the electrical systems. In this work many configurations of
electric fault current limiters were studied using superconducting ceramic materials of high
transition temperature (HTS), specially the resistive superconducting fault current limiters in
form of helical coils with BSCCO superconducting tapes. The methodology for the
electromagnetic calculation, project, construction and tests of the superconducting coils of the
fault current limiter was carried out along with the HTS tape characterization under external
magnetic field influence in order to determine the conditions of electric current and magnetic
field for the transition from superconducting state to normal conducting state (quench). At the
end of this work two fault current limiters were built and tested showing that, although BSCCO
HTS tapes yet do not have good characteristics for fault current limiters application, when these
materials which tend to be developed reach applicability level, the technique to design and built
them is already available. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
7 |
Analise dos sistemas de proteção e controle de instalações industriais com geradores sincronos durante operação ilhada / Protection and control systems analysis of industrial plants with synchronous generators during islanded operationArioli, Fernanda Caseño Trindade, 1984- 13 August 2018 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T11:32:14Z (GMT). No. of bitstreams: 1
Trindade_FernandaCasenoLima_M.pdf: 1160331 bytes, checksum: 8645597088992da29acb335423c8dbc4 (MD5)
Previous issue date: 2009 / Resumo: Sistemas industriais modernos são instalações bastante complexas com elevado grau de automatização e com capacidade de operar de forma isolada (ilhada) da rede elétrica após a ocorrência de contingências devido à utilização de geradores próprios compostos principalmente por máquinas síncronas e turbinas térmicas. Tais instalações, na presença de geradores, são denominadas genericamente como consumidores autoprodutores. Como muitos desses autoprodutores são conectados em redes de distribuição e subtransmissão de energia elétrica, tais consumidores estão sujeitos às normas técnicas requeridas por essas concessionárias. Assim, a desconexão da instalação industrial logo após a ocorrência de um ilhamento na rede de distribuição é um procedimento obrigatório. Imediatamente após a detecção do ilhamento pelo sistema de proteção da instalação industrial, a rede de distribuição e o sistema industrial são separados (isolados). Esta separação é realizada através da abertura do disjuntor instalado no lado de baixa tensão do transformador (lado do consumidor) que faz a conexão entre os dois sistemas. Então, a concessionária pode realizar os procedimentos necessários para reenergização da rede. Logo após a realização da separação dos sistemas, é necessário adotar uma série de medidas que garanta que o sistema industrial possa continuar operando isoladamente de forma adequada. Basicamente, três ações devem ser tomadas: (a) mudança do modo de operação do regulador de velocidade e do sistema de excitação dos geradores síncronos; (b) implementação do sistema de rejeição de carga e (c) alteração dos ajustes dos relés de sobrecorrente do sistema de proteção da rede industrial. Nesse contexto, o objetivo desta dissertação de mestrado é investigar tais procedimentos e propor metodologias de análise dessas questões previamente mencionadas de forma a obter um melhor entendimento do problema. Com o desenvolvimento dessas metodologias, objetiva-se que os estudos desses procedimentos automáticos possam ser realizados de forma mais eficiente e sistemática. / Abstract: Modern industrial systems are very sophisticated installations with a high number of automatic processes and capability of isolated (islanded) operation after contingences by using onsite generators composed mainly by synchronous machines and steam turbines. Such installations, in the presence of generators, are generically called autoproducers. Since many of these autoproducers are connected to electrical power distribution and subtransmission grids, they must respect the technical recommendations imposed by these utilities. As a consequence, the disconnection of these systems from the grid after islanding occurrence is a mandatory procedure.
Soon after the islanding detection by the industrial protection system, the industry and the grid must be electrically separated (isolated) by opening the circuit breaker installed at the low voltage side of the interconnection transformer. Thus, after the separation, the utility can carry out the necessary technical procedures to restore the network. From the industrial system perspective, after the separation, it is necessary to take control actions to guarantee that the industrial system continues operating with quality and reliability. Basically, three actions must be taken: (a) change the operation mode of the speed governor and excitation system of the generators; (b) implement the load shedding system and (c) change the settings of the protection system overcurrent relays. In this context, the objective of this master thesis is to investigate these procedures and propose methods for analysis in order to obtain a better understanding of these issues. With this methodologies development, it is expected that new automatic proceedings can be achieved in a more efficient and systematic way. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
8 |
Estudo de controle e proteção para sistemas de transmissão HVDC multiterminais baseados em conversores modulares multiníveis. / Control and protection study of multiterminal HVDC transmission systems based on modular multilevel converters.Suzuki, Nayara Yuko 28 June 2018 (has links)
O crescente interesse por sistemas de transmissão do tipo VSC-based HVDC (VSCHVDC) como alternativa aos atuais tem levado à necessidade de estudos sobre o principal desafio associado à sua implantação, que é o desenvolvimento de um esquema de proteção que seja rápido e que identifique a zona de proteção na qual uma eventual falta tenha ocorrido, respeitando-se assim o princípio de seletividade. Para estudo de um sistema de proteção que atenda a estes requisitos, foi utilizada neste trabalho uma rede com quatro terminais e transmissão High-Voltage Direct Current (HVDC), implementada com conversores modulares multiníveis (Modular Multilevel Converter (MMC)) e simulada em situações de contingência. Grandezas medidas nos elos de Corrente Contínua (CC) ligados a um dos terminais foram utilizadas para identificar a ocorrência de uma contingência na rede e então para decidir se trata-se de uma falta interna à zona de proteção considerada na análise. Para classificar as faltas em interna ou externa, observaram-se os espectros dos sinais de tensão CC em um terminal, calculados sobre uma janela do sinal através de Fast Fourier Transform (FFT), para várias situações de falta. Destes espectros, notou-se que uma característica varia de acordo com a distância da falta até o terminal, com o fato de a falta ser interna ou externa e com a resistência de falta. Através desta característica, denominada aqui \"frequência de centro de massa\", foi possível distinguir as faltas internas com resistências de falta baixas do restante dos eventos testados. Considerando-se apenas este parâmetro, não foi possível classificar corretamente faltas internas com resistência de falta muito alta. / The growing interest in VSC-based HVDC (VSC-HVDC) transmission systems as an alternative to the current ones has required studies about the the main challenge associated with its application, which is the development of a protection scheme that is able to both fast and efficiently determine the protection zone where a fault may have happened so as to achieve selectivity. In order to study a protection system that complies with those requirements, a High-Voltage Direct Current (HVDC) transmission system with four terminals implemented with Modular Multilevel Converter (MMC) converters was simulated under contingency condition. Electrical quantities measured in one of the terminal\'s Direct Current (DC) links were used to determine the occurrence of a fault event in the system, as well as to decide whether that event belonged to the protection zone considered in the analysis. Spectra obtained via Fast Fourier Transform (FFT) over a window of the DC voltage measured in one of the terminals were observed in order to discriminate between internal and external fault events. From these observations, it was noticed that a certain characteristic, named here \"center of mass frequency\", varies according to the distance between the fault location and the terminal, fault resistance, as well as whether that the fault is either internal or external to the analysed protection zone. By using this characteristic, it was possible to tell internal faults with low resistance fault from other events. Considering this parameter only, it was not possible to correctly classify internal faults with high fault resistance.
|
9 |
Estudo de controle e proteção para sistemas de transmissão HVDC multiterminais baseados em conversores modulares multiníveis. / Control and protection study of multiterminal HVDC transmission systems based on modular multilevel converters.Nayara Yuko Suzuki 28 June 2018 (has links)
O crescente interesse por sistemas de transmissão do tipo VSC-based HVDC (VSCHVDC) como alternativa aos atuais tem levado à necessidade de estudos sobre o principal desafio associado à sua implantação, que é o desenvolvimento de um esquema de proteção que seja rápido e que identifique a zona de proteção na qual uma eventual falta tenha ocorrido, respeitando-se assim o princípio de seletividade. Para estudo de um sistema de proteção que atenda a estes requisitos, foi utilizada neste trabalho uma rede com quatro terminais e transmissão High-Voltage Direct Current (HVDC), implementada com conversores modulares multiníveis (Modular Multilevel Converter (MMC)) e simulada em situações de contingência. Grandezas medidas nos elos de Corrente Contínua (CC) ligados a um dos terminais foram utilizadas para identificar a ocorrência de uma contingência na rede e então para decidir se trata-se de uma falta interna à zona de proteção considerada na análise. Para classificar as faltas em interna ou externa, observaram-se os espectros dos sinais de tensão CC em um terminal, calculados sobre uma janela do sinal através de Fast Fourier Transform (FFT), para várias situações de falta. Destes espectros, notou-se que uma característica varia de acordo com a distância da falta até o terminal, com o fato de a falta ser interna ou externa e com a resistência de falta. Através desta característica, denominada aqui \"frequência de centro de massa\", foi possível distinguir as faltas internas com resistências de falta baixas do restante dos eventos testados. Considerando-se apenas este parâmetro, não foi possível classificar corretamente faltas internas com resistência de falta muito alta. / The growing interest in VSC-based HVDC (VSC-HVDC) transmission systems as an alternative to the current ones has required studies about the the main challenge associated with its application, which is the development of a protection scheme that is able to both fast and efficiently determine the protection zone where a fault may have happened so as to achieve selectivity. In order to study a protection system that complies with those requirements, a High-Voltage Direct Current (HVDC) transmission system with four terminals implemented with Modular Multilevel Converter (MMC) converters was simulated under contingency condition. Electrical quantities measured in one of the terminal\'s Direct Current (DC) links were used to determine the occurrence of a fault event in the system, as well as to decide whether that event belonged to the protection zone considered in the analysis. Spectra obtained via Fast Fourier Transform (FFT) over a window of the DC voltage measured in one of the terminals were observed in order to discriminate between internal and external fault events. From these observations, it was noticed that a certain characteristic, named here \"center of mass frequency\", varies according to the distance between the fault location and the terminal, fault resistance, as well as whether that the fault is either internal or external to the analysed protection zone. By using this characteristic, it was possible to tell internal faults with low resistance fault from other events. Considering this parameter only, it was not possible to correctly classify internal faults with high fault resistance.
|
10 |
Análise do impacto da proteção antiilhamento na estabilidade de geradores conectados via inversores / Stability analysis of inverter-based distributed generators with antiislanding protectionRicciardi, Tiago Rodarte, 1986- 16 August 2018 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T21:04:55Z (GMT). No. of bitstreams: 1
Ricciardi_TiagoRodarte_M.pdf: 3291776 bytes, checksum: c647c3c5eaa394835294087b10e89863 (MD5)
Previous issue date: 2010 / Resumo: O uso de geradores conectados via inversores em redes de distribuição de energia elétrica tem aumentado consideravelmente nos últimos anos em razão dos avanços obtidos nas tecnologias de células a combustível e fotovoltaicas bem como de microturbinas e turbinas eólicas. Nesse contexto, a utilização de sistemas de proteção antiilhamento no ponto de conexão do gerador com a rede elétrica é uma das exigências previstas nos principais guias técnicos empregados pelas concessionárias. Ilhamento ocorre quando uma parte da rede de distribuição torna-se eletricamente isolada da fonte de energia principal (subestação), mas continua a ser energizada por geradores distribuídos conectados no subsistema isolado. No caso particular dos geradores conectados via inversores, os principais dispositivos utilizados comercialmente para fornecer proteção antiilhamento são baseados no conceito de realimentação positiva, cuja idéia básica é empregar um dos parâmetros que definem a tensão terminal do gerador como sinal de realimentação positiva no seu sistema controle. Caso o gerador esteja conectado ao sistema de distribuição, a realimentação positiva não consegue, a priori, desestabilizar o gerador. Por outro lado, caso o gerador torne-se ilhado, a realimentação positiva fará com que o gerador se torne instável e, por conseguinte, a situação de ilhamento pode ser rapidamente detectada por relés de sub/sobre tensão e/ou sub/sob freqüência. Visto que tal esquema de proteção esforça-se para desestabilizar o gerador independentemente da ocorrência ou não de ilhamentos, é fundamental desenvolver ferramentas para analisar a estabilidade de redes com múltiplos geradores equipados com proteção antiilhamento via realimentação positiva. O objetivo desta dissertação de mestrado foi desenvolver uma série de modelos linearizados no espaço de estados para representar os principais dispositivos de proteção antiilhamento existentes comercialmente a fim de investigar a estabilidade frente a pequenas perturbações de sistemas de distribuição de energia elétrica com múltiplos geradores conectados via inversores utilizando-se análise modal / Abstract: The usage of inverter-based generators connected directly to electric Power distribution systems has considerably increased in recent years due to the technological advances of fuel and photovoltaic cells as well as microturbines and wind turbines. In this context, the usage of anti-islanding protection devices at the interconnection point is required by the main technical guides utilized by the utilities. Islanding occurs when a portion of the distribution system becomes electrically isolated from the remainder of the power system, yet continues to be energized by distributed generators. In the case of inverter-based generators, the main devices commercially employed to supply anti-islanding protection are based on the positive feedback concept. These methods use the deviations of voltage frequency and/or magnitude from normal values as positive feedback signals into the control system to influence the operation of inverterbased distributed generators. If the generator is connected to a strong utility system, in priori, the destabilizing force of the positive feedback has a negligible impact and the generator can operate without difficulties. On the other hand, when the generator is islanded, the positive feedback can destabilize the generator easily. Such distinctively different generator behaviors facilitate the detection of islanding conditions by using under/over voltage and frequency relays. Since the positive feedback scheme is a destabilizing force, the impact of this scheme on the stability of system with multiples inverter-based generators is of concern. If the positive feedback gain is too high, the generator may become unstable even if it is connected to the main supply system. Thus, the objective of this master thesis is to develop several small-signal models to investigate the stability of distribution network with multiple inverter-based generators with positive feedback anti-islanding protection by using modal analysis / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
Page generated in 0.0576 seconds