• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5292
  • 265
  • 34
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 1
  • Tagged with
  • 5599
  • 5599
  • 1967
  • 1900
  • 1569
  • 1555
  • 1555
  • 1387
  • 619
  • 568
  • 439
  • 341
  • 321
  • 319
  • 256
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
731

Mapa de risco de erosão e escorregamento das encostas com ocupações desordenadas no Município de Camaragibe -PE

Patrícia Nunes Bandeira, Ana January 2003 (has links)
Made available in DSpace on 2014-06-12T17:41:54Z (GMT). No. of bitstreams: 2 arquivo6627_1.pdf: 8984009 bytes, checksum: c573005f1d49ebc3e323b220d73c3a79 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Universidade Federal do Ceará / O crescimento das cidades associado à falta de política habitacional tem provocado graves problemas sociais como a ocupação desordenada nas encostas e nas áreas alagadas. Este trabalho tem como objetivo principal o estudo das características físicas e ambientais do município de Camaragibe, para avaliação do potencial de risco de erosão e escorregamento das encostas com ocupações precárias. Tal estudo faz parte de um convênio entre a Área de Geotecnia, Deptº de Engenharia Civil da UFPE, e a Prefeitura Municipal de Camaragibe, visando auxiliar no Plano Diretor da cidade e contribuir para o planejamento urbano. Camaragibe está localizada na Região Metropolitana do Recife com área de 52,9 km2 e população de 128.702 habitantes, com clima tropical chuvoso do tipo As pela classificação de Köppen. Os morros correspondem a 80% da área do município, onde nas ocupações desordenadas nas encostas é freqüente a ocorrência de escorregamentos e processos de erosão no período chuvoso. Geologicamente a cidade apresenta sedimentos da Formação Barreiras, rochas do Embasamento Cristalino recobertas pelo seu solo residual e os depósitos aluvionais. Foi avaliada a situação de risco de 70 setores de encostas, correspondendo a uma área de 293 ha. Para a avaliação do potencial de risco utilizou-se a metodologia qualitativa de GUSMÃO FILHO et al. (1992), adaptada às características das áreas e às recomendações do Programa de Prevenção e Erradicação de Riscos em Assentamentos Precários, do Ministério das Cidades. O município apresentou cerca de 62 ha de área de risco alto a muito alto (21% dos setores de encostas avaliados), 116 ha de área com risco médio (40%) e 115 ha de área com risco baixo (39%). Nos setores constituídos por sedimentos da Formação Barreiras verificaram-se que o fator predominante de risco é o geológico sendo fortemente induzido pelos fatores topográfico e ambiental, podendo desse modo receber tratamento alternativo. Nos setores constituídos pelo solo residual, o fator antrópico, expresso pelo fator ambiental é o mais importante para a deflagração dos escorregamentos, sendo necessário tratá-lo nesses setores, com obras de macro e microdrenagens, esgotamento sanitário e proteção superficial entre outros. Para dar subsídios a projetos de engenharia nas intervenções, analisou-se o material de três áreas piloto em sedimentos da Formação Barreiras e no solo residual maduro granítico, onde foram realizados ensaios básicos de caracterização geotécnica. Os sedimentos da Formação Barreiras de leque proximal apresentaram camadas predominantemente de silte argiloso e arenoso com alta (MH) e baixa plasticidades (ML) sendo susceptível aerosão. A Formação Barreiras de canal fluvial apresentou camadas de textura grossa classificada como areia argilosa (SC) e areia siltosa (SM). O solo residual maduro é constituído predominantemente de uma argila de baixa compressibilidade (CL) apresentando camadas intercaladas de areia argilosa (SC). Resultados de ensaios de cisalhamento direto indicaram maiores valores de φ para o solo residual maduro (φ = 37º), na camada classificada de CL. Para Formação Barreiras, φ foi de 29º, na camada classificada de ML. Os parâmetros de caracterização geotécnica encontrados podem ser utilizados como subsídios técnicos para intervenções nas áreas
732

Remediação de sitios contaminados atraves da extração de vapores do solo

Roehrig, Jackson 18 December 1991 (has links)
Orientador: Eugenio da Motta Singer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-14T02:47:06Z (GMT). No. of bitstreams: 1 Roehrig_Jackson_M.pdf: 3444161 bytes, checksum: 01f72e9b35dc5ec3afb329fb7887e5be (MD5) Previous issue date: 1991 / Resumo: : A Extração de Vapores do Solo (EVS) é uma técnica frequentemente aplicada na remediação de zonas vadosas contaminadas por compostos voláteis, como por exemplo gasolina e solventes orgâno-clorados, bem como no controle da migração de gases, como por exemplo o metano. Consiste da formação de um gradiente de pressões no solo, responsável pelo fluxo preferencial de gases e vapores. Este trabalho apresenta as equações de fluxo de gases em meios porosos, e compara os resultados correspondentes com as equações de fluxo de águas subterrâneas.As equações de equilíbrio entre as fases do solo são analisadas a partir dos fatores que afetam a EVS. Um modelo simplificado descrevendo a extração de vapores do solo é desenvolvido a partir destas equações básicas. Considerando-se o solo homogêneo e equilíbrio instantâneo entre fases, o modelo proposto também leva em consideração os efeitos decorrentes da presença de co-solventes. Finalmente, a relevância de alguns parâmetros tais como fração de carbono orgânico, umidade do solo e fração de co-solvente é analisada a partir de um exemplo de aplicação para um caso típico... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The Soil Vapor Extraction (EVS) is a technique frequently applied in the remediation of contaminated vadose zones by volatile compounds such as gasoline and chlorinated organic solvents, as well as on the gas migration, as methane for example. The procedure consists on creating apressure gradient in the soil, inducing preferencial flow of gases and vapours. This work presents the gas flow equations in the porous media and compares the corresponding results against established groundwater flow. The soil phase equilibrium equations are analysed under the light of the controlling factors over EVS. A simplified model describing vapour extraction is developed from those basic equations. Assuming homogeneous soil and instantaneous equilibrium amongst phases, the presently proposed model also takes into account the effects brought about by the presence of co-solvents. Finally, the relevance of some parameters such as organic carbon fraction, soil humidity and co-solvent fraction are analysed under one typical application case... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Civil
733

Influência da adição de cinza volante na elevação de temperatura de concretos aplicados em blocos de fundação

Junckes, Ricardo January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil. Florianópolis, 2015. / Made available in DSpace on 2016-05-24T17:48:16Z (GMT). No. of bitstreams: 1 338874.pdf: 3145391 bytes, checksum: 2768ad4229722dfd9fbf5b32c9e5d6b9 (MD5) Previous issue date: 2015 / Atualmente a estrutura de grandes edifícios tem requerido a construção de grandes blocos em concreto armado para o coroamento de suas fundações. Esses blocos, devido ao calor gerado pelo processo de hidratação do cimento, aliado ao seu grande volume e às características térmicas do concreto, são submetidos a elevadas temperaturas em seu interior, muitas vezes acima de 70 ºC. A utilização de cinza volante, quando aplicada em substituição parcial do cimento Portland, é tida como uma solução que pode minimizar o processo de elevação de temperatura. Contudo, como as resistências características desses blocos são geralmente especificadas para idades de 28 dias, e a ação pozolânica das cinzas volantes é lenta, geralmente o consumo de aglomerante das misturas é mais elevado do que quando se utiliza somente cimento Portland, pondo em dúvida a eficácia do uso das cinzas volantes para a redução da temperatura máxima a ser alcançada neste tipo de estrutura, que ocorre poucos dias após a concretagem. Assim sendo, o presente trabalho tem o objetivo de avaliar o efeito da substituição parcial de cimento Portland por cinza volante sobre a elevação de temperatura do concreto submetido a uma elevação adiabática de temperatura, durante sua cura nas idades iniciais e sobre a sua resistência à compressão, para diferentes tipos de cura. Para isso, foi desenvolvido um calorímetro adiabático com dimensões compatíveis para este estudo. Os concretos testados foram produzidos com resistência característica à compressão a 28 dias de 35 MPa, 45 MPa e 55 MPa, sob cura em temperatura de 23 oC, e todos receberam substituições de cimento por cinza volante nas seguintes porcentagens: 0% (referência), 15%, 30% e 45%. Sua elevação de temperatura foi monitorada durante as primeiras 72 horas após a mistura, e a resistência à compressão do concreto foi avaliada aos 28 dias de idade para diferentes temperaturas de cura. Além disso, a influência da cinza volante sobre o consumo de hidróxido de cálcio foi quantificada por ensaios de termogravimetria, em pastas preparadas com as mesmas proporções das utilizadas nos concretos testados. Os resultados demonstraram que a utilização de cinza volante em concretos submetidos à elevação autógena de temperatura não levou a uma redução significativa no coeficiente de elevação adiabática de temperatura, se comparada com as misturas de referência, e que cura a elevadas temperaturas nas idades iniciais traz prejuízos para a resistência à compressão aos 28 dias de idade.<br> / Abstract : Large reinforced concrete pile caps have been generally used in foundations of tall building. These pile caps, due to the heat generated by cement hydration process, coupled with its large volume and thermal characteristics of the concrete, are subjected to high temperatures, often above 70 °C, leading to crack formation. The use of fly ash as partial replacement of the Portland cement is one the solutions adopted to reduce this temperature rise. However, since the compressive strength of these structural elements are generally specified for 28 days and pozzolanic activity of fly ash is slow, typically the amount of binder used in these mixtures is higher than those of using exclusively Portland cement. This fact jeopardizes the efficacy of fly ash to reduce the maximum temperature achieved in this type of structure, which occurs a few days after concrete placement. Therefore, this study aims at evaluating the effect of partial replacement of Portland cement by fly ash on temperature rise of concrete subjected to adiabatic conditions during its curing at early ages and on the compressive strength for different types of curing. The experimental tests were carried out in an adiabatic calorimeter specially designed for this study. The concrete mixtures were produced with characteristic compressive strength of 35 MPa, 45 MPa and 55 MPa at 28 days. The cement replacement by fly ash where: 0% (reference), 15%, 30% and 45%. The temperature rise was monitored during the first 72 hours after mixing and the compression strength of concrete was assessed at 28 days for different curing conditions. In addition, the influence of fly ash on the calcium hydroxide consumption was measured by thermogravimetric tests in pastes prepared with the same proportions as those used in the concrete previously tested. The results obtained demonstrated that the replacement of cement by fly ash in concrete subjected to the autogenous temperature increase did not reduce the adiabatic temperature rise coefficient. Moreover, high temperature curing during early ages decreases the compressive strength of concrete mixtures after 28 days.
734

Avaliação experimental da interação de paredes de blocos de concreto de alta resistência sob ações verticais / Experimental evaluation of the interaction of high strenght concrete block walls under vertical loads

Castro, Lucas de Oliveira 21 August 2015 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2015-11-04T15:13:39Z No. of bitstreams: 1 texto completo.pdf: 5854616 bytes, checksum: b92aa55d530849787ca61c26ad02bcd1 (MD5) / Made available in DSpace on 2015-11-04T15:13:39Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5854616 bytes, checksum: b92aa55d530849787ca61c26ad02bcd1 (MD5) Previous issue date: 2015-08-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superio / Este trabalho tem como objetivo avaliar a interação entre paredes de alvenaria estrutural de blocos de concreto de alto desempenho (CAD), sob ações verticais. Foram ensaiadas duas séries de painéis em formato H em escala real, com amarração direta, sendo três painéis com a parede central (alma) apoiada e três painéis sem o apoio. O programa experimental abrangeu também ensaios de caracterização física e mecânica dos blocos, dos prismas de dois blocos e da argamassa. Foram obtidos os módulos de deformação, tanto para as argamassas, blocos e prismas, quanto para os painéis de alvenaria e o coeficiente de Poisson para os blocos. Para escolha do traço de argamassa, foram avaliadas três séries de prismas, utilizando-se argamassas com resistências médias à compressão iguais a 40% (série 1), 70% (série 2) e 100% (série 3) da resistência característica à compressão dos blocos, respectivamente, referida à área bruta. Todas as argamassas utilizadas no programa experimental foram dosadas utilizando o método proposto por Santos (2014). Com base nos resultados dessas séries, foram confeccionadas e ensaiadas duas novas séries, ambas utilizando a argamassa da série 2, sendo uma com argamassamento parcial nas paredes longitudinais (série 4) e outra com argamassamento total para sua caracterização (série 5). Os painéis de alvenaria utilizaram o segundo traço em sua confecção. Os resultados dos prismas permitiram avaliação da eficiência prisma/bloco, além dos modos de ruptura, que variaram para as diferentes configurações de ensaio. Os valores do módulo de deformação e coeficiente de Poisson médio mostraram uma boa relação com as recomendações da norma. A análise de variância das amostras submetidas à compressão (prismas) mostra que existe influência da resistência da argamassa na resistência à compressão dos prismas. Os resultados dos ensaios de painéis mostraram que os modos de ruptura foram predominantemente na parede central, abaixo do ponto de aplicação da carga com trincas na diagonal e escalonada e que existe transferência de carga da parede central (alma) para as abas, principalmente no trecho inferior dos painéis. / This study aims to evaluate the interaction between structural masonry walls of high strenght concrete blocks, under vertical loads. Two panels series were studied in format “H”, full scale and direct bond, three panels with the central wall (web) support and three panels without central wall support. The experimental program also included tests of physical and mechanical characterizations of mortar, blocks and prisms of two blocks. The modulus of elasticity were obtained for mortars, blocks, prism and for masonry painels; Poisson’s ratio was obtained for blocks. Three prisms series were evaluated to select the mortar’s line, each using a different mortar trace with mean resistance to compression equal to 40% (series 1), 70% (series 2) and 100% (series 3) of the block’s compressive strength characteristic, referred to its gross area. All mortars used in the experimental program were dosaged using the method proposed by Santos (2014). Two new series (serie 4 and serie 5) were made based on the results of these three series, both using the mortar from serie 2; serie 4 was made with partial mortar on longitudinal walls, while serie 5 was made with full mortar for its characterization. The results of the prisms allowed the evaluation of the prism/block efficiency, in addition to the failure modes, which changed for different test configurations. The values of the modulus of elasticity and Poisson’s ratio average showed good relationship with standard recommendations. The variance analysis of the samples subjected to compression (prism) shows that there is influence of mortar strength in the compression resistance of the prisms. To making masonry panels was used the second mortar trace. The results of the panel test show that the failure mode was predominantly in the central wall, below the load application point, with diagonal and staggered cracks, and that there is charge transfer (web) for the flages, mainly in the bottom section of the panels.
735

Contribuição ao estudo de lajes pre-fabricadas com vigas treliçadas

Caixeta, Delma Pareira 29 September 1998 (has links)
Orientador: Luiz Roberto Sobreira de Agostini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-24T08:41:48Z (GMT). No. of bitstreams: 1 Caixeta_DelmaPareira_M.pdf: 4662539 bytes, checksum: 5d1b515ee2268d6e9d00a570efce8491 (MD5) Previous issue date: 1998 / Resumo: Os elementos pré-fabricados têm cada vez mais ocupado seu espaço nas mais diversas obras de Engenharia Civil. As lajes treliçadas surgiram como uma variação destes elementos. Neste trabalho procurou-se reunir o máximo de informações que possibilitem caracterizar este elemento em nível nacional, bem como ele é tratado em. paises europeus, como a França. Através do ensaio de flexão simples em dez modelos, quatro em seção retangular e seis em seção T, procurou-se representar de forma satisfatória o modo real de sua utilização em obra, buscando a caracterização da vigota treliçada. Foram feitas medidas das flechas verticais, deformações nas barras do banzo superior e diagonais e a caracterização do desenvolvimento e propagação das fissuras. Os ensaios mostraram que as diagonais pouco trabalham no combate aos esforços cortantes, as fissuras aparecem para as primeiras cargas aplicadas e há necessidade de aplicação da contra-flecha na fase de concretagem da laje / Abstract: The pre-fabricated elements has been occupying its space more and more in the several buildings of Civil Engineering. The trussed slabs appeared as a variation of these elements. This work tried to meet the maximum information that facilitate to characterize this element in national level, as well as he is treated at European countries, like France. Through the rehearsal of simple bending in ten models, four in rectangular section and six in section T, tried to represent in a satisfactory way the real manner of its use in buildings, looking for the characterization of the trussed beam. Measures were made of the vertical arrows, deformations in the top bars and diagonals and the characterization of the development and propagation of the cracks. The rehearsals showed that the diagonals don't work hard in the action of the shear efforts, the cracks appear for the first applied loads and there is need of application of the counter-arrows in the concrete stage of the precast slab / Mestrado / Estruturas / Mestre em Engenharia Civil
736

Determinação de coeficiente cinético de agregação com uso de método direto /

Manetta, Lívia Savioli. January 2019 (has links)
Orientador: Rodrigo Braga Moruzzi / Banca: Sidney Seckler Ferreira Filho / Banca: André Luiz de Oliveira / Banca: Samuel Conceição de Oliveira / Banca: Maria da Graça Bontempo Vaz Rasteiro / Resumo: Este trabalho visa estabelecer um procedimento para a obtenção de parâmetro cinético de agregação por método direto e dinâmico, livre de distúrbios analíticos significativos, como a sedimentação de partículas e com resultados obtidos através do auxílio do equipamento PDA (Photometric Dispersion Analyser) juntamente com técnica que utiliza análise digital de imagem com dados tratados por software específico. A modelagem do processo foi realizada por meio da adaptação da modelagem clássica de agregação e ruptura com vistas à obtenção dos parâmetros cinéticos do processo de floculação diretamente no início da etapa de agregação das partículas que ocorre nos primeiros segundos do processo de floculação. Foi possível estabelecer uma relação entre a resposta do equipamento PDA e apenas o crescimento no diâmetro dos agregados formados no início do processo de floculação, informação obtida por meio de técnica de análise de imagem, assim possibilitando a correlação entre ambos os parâmetros e obtenção do coeficiente de agregação do modelo cinético. Os resultados da pesquisa auxiliam no entendimento do fenômeno e do processo de floculação, etapa essa fundamental para o desempenho de sistemas de tratamento de água para abastecimento / Abstract: This work aims to establish a procedure for obtaining a kinetic parameter of aggregation by direct and dynamic method, free of significant analytical disturbances, such as particle sedimentation and with results obtained through the aid of PDA (Photometric Dispersion Analyzer) equipment together with technique that uses digital image analysis with data processed by specific software. The process modeling was performed by adapting the classical aggregation and rupture modeling to obtain the kinetic parameters of the flocculation process directly at the beginning of the particle aggregation step that occurs in the first seconds of the flocculation process. It was possible to establish a relationship between the response of the PDA equipment and only the growth in the diameter of the aggregates formed at the beginning of the flocculation process, information obtained by image analysis technique, thus enabling the correlation between both parameters and obtaining the coefficient. of aggregation of the kinetic model. The results of the research help in understanding the phenomenon and the flocculation process, a step that is fundamental for the performance of water treatment systems for water supply / Doutor
737

Análise e Contextualização da Informação Técnica na Construção em Usos BIM - Estudo de Caso

Rui Filipe Tavares Pina 28 August 2019 (has links)
No description available.
738

Reabilitação da Estrutura de Betão Armado do Cavalete de S. Vicente

Pedro Miguel Miranda Dias 27 August 2019 (has links)
No description available.
739

Soluções Otimizadas de Estruturas Metálicas em Aço Leve Para Parques Fotovoltaicos

Afonso Schoeppen Magalhães de Castro Oliveira 27 August 2019 (has links)
No description available.
740

Conceção, Especificação e Pormenorização de Coberturas Verdes

Márcia Filipa Pessoa Leal 27 August 2019 (has links)
No description available.

Page generated in 0.1118 seconds