• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilizing Hybrid Ensemble Prediction Model In Order to Predict Energy Demand in Sweden : A Machine-Learning Approach / En maskininlärningsmetod som använder hybridensembleprediktionsmodell för att förutsäga energiefterfrågan i Sverige

Su, Binxin January 2022 (has links)
Conventional machine learning (ML) models and algorithms are constantly advancing at a fast pace. Most of this development are due to the implementation of hybrid- and ensemble techniques that are powerful tools to complement and empower the efficiency of the algorithms. At the same time, the development and demand for renewable energy sources are rapidly increasing driven by political and environmental issues in which failure to act fast enough, could lead to an existential crisis. With the phasing of non-renewable to renewable energy sources, new challenges arise due to its intermittent and variable nature. Accurate forecasting techniques plays a crucial role in addressing these challenges. In this thesis, I present a hybrid ensemble machine learning model based upon stacking, utilizing a Gradient Boosted Tree as a meta-learner to predict the energy demand for the energy area SE3 in Sweden. The Hybrid model is based on three composite models: XGBoost, CatBoost and Random Forest (RF); utilizing only features extracted from the timeseries data. For training and testing the proposed Hybrid model, hourly demand load data was gathered from Svenska Kraftnät, measuring energy consumption for the energy area SE3 from year 2016-2021. The forecasting results of the models are measured using a regression score (R-squared, which measures Explained Variance) and Accuracy (measured in terms of Mean Absolute Percentage Error). The result shows that in an experimental setting, the Hybrid model reaches a R-squared score of 0.9785 and an accuracy of 97.85%. When utilized for day-ahead prediction on unseen data outside of the scope of the training dataset, the Hybrid model reaches a R-squared score of 0.9764 and an Accuracy of 93.43%. This thesis concludes that the proposed methodology can be utilized to accurately predict the variance in the energy demand and can serve as a framework to decision makers in order to accurately predict the energy demand in Sweden. / Konventionella maskininlärningsmodeller (ML) och algoritmer utvecklas ständigt i snabb takt. Det mesta av denna utveckling beror på implementeringen av hybrid- och ensembletekniker som är kraftfulla verktyg för att komplettera och stärka effektiviteten hos algoritmer. Samtidigt ökar utvecklingen och efterfrågan på förnybara energikällor snabbt, drivet av politiska och miljömässiga motiv, där underlåtenhet att agera tillräckligt snabbt kan leda till en existentiell kris. Med utfasningen av icke-förnybara till förnybara energikällor uppstår nya utmaningar på grund av dess intermittenta och varierande karaktär. Noggranna prognostekniker spelar en avgörande roll för att hantera dessa utmaningar. I det här examensarbetet presenterar jag en hybrid ensemble maskininlärningsmodell baserad på stacking, med användning av ett Gradient Boosted Decision Tree (GBDT) som en meta-learner för att förutsäga energibehovet för energiområdet SE3 i Sverige. Hybridmodellen är baserad på tre kompositmodeller: XGBoost, CatBoost och Random Forest (RF) och använder endast features extraherade från tidsseriedata. För att utbilda och testa den föreslagna hybridmodellen samlades timbelastningsdata från Svenska Kraftnät, som mäter energiförbrukningen för energiområdet SE3 från år 2016-2021. Modellernas prognosresultat mäts med hjälp av ett regressionsmått (R-kvadrat, som mäter Explained Variance) och Accuracy (mätt i termer av Mean Absolute Percentage Error). Resultatet visar att i en experimentell miljö når hybridmodellen en R-kvadratvärde på 0,9785 och en Accuracy på 97,85%. När hybridmodellen används för att förutsäga energiförbrukningen dagen framåt på data utanför omfattningen av träningsdata, når hybridmodellen ett R-kvadratpoäng på 0,9764 och en Accuracy på 93,43%. Denna avhandling drar slutsatsen att den föreslagna metoden kan användas för att korrekt förutsäga variansen i energibehovet och kan fungera som ett ramverk för beslutsfattare för att korrekt prognostisera energibehovet i Sverige.
2

Digital Twin-based Intrusion Detection for Industrial Control Systems

Varghese, Seba January 2021 (has links)
Digital twins for industrial control systems have gained significant interest over recent years. This attention is mainly because of the advanced capabilities offered by digital twins in the areas of simulation, optimization, and predictive maintenance. Some recent studies discuss the possibility of using digital twins for intrusion detection in industrial control systems. To this end, this thesis aims to propose a security framework for industrial control systems including its digital twin for security monitoring and a machine learning-based intrusion detection system for real-time intrusion detection. The digital twin solution used in this study is a standalone simulation of an industrial filling plant available as open-source. After thoroughly evaluating the implementation aspects of the existing knowledge-driven open-source digital twin solutions of industrial control systems, this solution is chosen. The cybersecurity analysis approach utilizes this digital twin to model and execute different realistic process-aware attack scenarios and generate a training dataset reflecting the process measurements under normal operations and attack scenarios. A total of 23 attack scenarios are modelled and executed in the digital twin and these scenarios belong to four different attack types, naming command injection, network DoS, calculated measurement injection, and naive measurement injection. Furthermore, the proposed framework also includes a machine learning-based intrusion detection system. This intrusion detection system is designed in two stages. The first stage involves an offline evaluation of the performance of eight different supervised machine learning algorithms on the labelled dataset. In the second stage, a stacked ensemble classifier model that combines the best performing supervised algorithms on different training dataset labels is modelled as the final machine learning model. This stacked ensemble model is trained offline using the labelled dataset and then used for classifying the incoming data samples from the digital twin during the live operation of the system. The results show that the designed intrusion detection system is capable of detecting and classifying intrusions in near real-time (0.1 seconds). The practicality and benefits of the proposed digital twin-based security framework are also discussed in this work. / Digitala tvillingar för industriella styrsystem har fått ett betydande intresse under de senaste åren. Denna uppmärksamhet beror främst på de avancerade möjligheter som digitala tvillingar erbjuder inom simulering, optimering och förutsägbart underhåll. Några färska studier diskuterar möjligheten att använda digitala tvillingar för intrångsdetektering i industriella styrsystem. För detta ändamål syftar denna avhandling till att föreslå ett säkerhetsramverk för industriella styrsystem inklusive dess digitala tvilling för säkerhetsövervakning och ett maskininlärningsbaserat intrångsdetekteringssystem för intrångsdetektering i realtid. Den digitala tvillinglösningen som används i denna studie är en fristående simulering av en industriell fyllningsanläggning som finns tillgänglig som öppen källkod. Efter noggrann utvärdering av implementeringsaspekterna för de befintliga kunskapsdrivna digitala tvillinglösningarna med öppen källkod för industriella styrsystem, väljs denna lösning. Cybersäkerhetsanalysmetoden använder denna digitala tvilling för att modellera och exekvera olika realistiska processmedvetna attackscenarier och generera en utbildningsdataset som återspeglar processmätningarna under normala operationer och attackscenarier. Totalt 23 angreppsscenarier modelleras och utförs i den digitala tvillingen och dessa scenarier tillhör fyra olika angreppstyper, namnskommandoinjektion, nätverks -DoS, beräknad mätinjektion och naiv mätinjektion. Dessutom innehåller det föreslagna ramverket också ett maskininlärningsbaserat system för intrångsdetektering. Detta intrångsdetekteringssystem är utformat i två steg. Det första steget innebär en offline -utvärdering av prestanda för åtta olika algoritmer för maskininlärning övervakad på den märkta datauppsättningen. I det andra steget modelleras en staplad ensemble -klassificerarmodell som kombinerar de bäst presterande övervakade algoritmerna på olika etiketter för utbildningsdataset som den slutliga modellen för maskininlärning. Denna staplade ensemblemodell tränas offline med hjälp av den märkta datauppsättningen och används sedan för att klassificera inkommande dataprover från den digitala tvillingen under systemets levande drift. Resultaten visar att det konstruerade intrångsdetekteringssystemet kan upptäcka och klassificera intrång i nära realtid (0,1 sekunder). Det praktiska och fördelarna med den föreslagna digitala tvillingbaserade säkerhetsramen diskuteras också i detta arbete.

Page generated in 0.0492 seconds