• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

On the efficient and sustainable utilisation of shallow geothermal energy by using borehole heat exchangers

Hein, Philipp Sebastian 16 January 2018 (has links) (PDF)
In the context of energy transition, geothermics play an important role for the heating and cooling supply of both residential and commercial buildings. Thereby, the increasingly and intensive utilisation of shallow geothermal resources bears the risk of over-exploitation and thus poses a future challenge to ensure the sustainability and safety of such systems. Particularly, the well-established technology of borehole heat exchanger-coupled ground source heat pumps is applied for the thermal exploitation of the shallow subsurface. Due to the complexity of the involved physical processes, numerical modelling proves to be a powerful tool to enhance process understanding as well as to aid the planning and design processes. Simulations can also support the management of thermal subsurface resources, planning and decision-making on city and regional scales. In this work, the so-called dual-continuum approach was adopted and enhanced to develop a coupled numerical model considering flow and heat transport processes in both the subsurface and borehole heat exchangers as well as the heat pumps’ performance characteristics, and including the relevant phenomena influencing the underlying processes. Beside the temperature fields, the efficiency and thus the consumption of electrical energy by the heat pump is computed, allowing for the quantification of operational costs and equivalent carbon-dioxide emissions. The model is validated and applied to a number of numerical studies. First, a comprehensive sensitivity analysis on the efficiency and sustainability of such systems is performed. Second, a method for the quantification of technically extractable shallow geothermal energy is proposed. This procedure is demonstrated by means of a case study for the city of Cologne, Germany and its implications are discussed. / Im Rahmen der Energiewende nimmt die Geothermie eine besondere Rolle in der thermische Gebäudeversorgung ein. Die zunehmende, intensive Nutzung oberflächennaher geothermischer Ressourcen erhöht die Gefahr der übermäßigen thermischen Ausbeutung des Untergrundes und stellt damit eine wachsende Herausforderung für die Nachhaltigkeit und Sicherheit solcher Systeme dar. Zur Erschließung oberflächennaher geothermischer Energie wird insbesondere die etablierte Technologie Erdwärmesonden-gekoppelter Wärmepumpen eingesetzt. Aufgrund der daran beteiligten komplexen physikalischen Prozesse erweisen sich numerische Modelle als leistungsfähiges Werkzeug zur Erweiterung des Prozessverständnisses und Unterstützung des Planungs- und Auslegungsprozesses. Zudem können Simulationen zum Management thermischer Ressourcen im Untergrund sowie zur Planung und politischen Entscheidungsfindung auf städtischen und regionalen Maßstäben beitragen. Im Rahmen dieser Arbeit wurde, basierend auf dem sogenannten ”dual-continuum approach” und unter Berücksichtigung des Einflusses der Wärmepumpe, ein erweitertes gekoppeltes numerisches Modell zur Abbildung der in Erdwärmesonden und dem Untergrund stattfindenden Strömungs- und Wärmetransportprozesse entwickelt. Das Modell ist in der Lage, alle relevanten Einflussfaktoren zu berücksichtigen. Neben den Temperaturfeldern im Untergrund und der Erdwärmesonde werden die Effizienz und damit der Stromverbrauch der Wärmepumpe simuliert. Damit können sowohl die Betriebskosten als auch der äquivalente CO 2 -Ausstoß abgeschätzt werden. Das Modell wurde validiert und in einer Reihe numerischer Studien eingesetzt. Zuerst wurde eine umfassende Sensitivitätsanalyse zur Effizienz und Nachhaltigkeit entsprechender Anlagen durchgeführt. Weiterhin wird ein Verfahren zur Quantifizierung des technisch nutzbaren, oberflächennahen geothermischen Potentials vorgestellt und anhand einer Fallstudie für die Stadt Köln demonstriert, gefolgt von einer Diskussion der Ergebnisse.
2

On the efficient and sustainable utilisation of shallow geothermal energy by using borehole heat exchangers

Hein, Philipp Sebastian 08 December 2017 (has links)
In the context of energy transition, geothermics play an important role for the heating and cooling supply of both residential and commercial buildings. Thereby, the increasingly and intensive utilisation of shallow geothermal resources bears the risk of over-exploitation and thus poses a future challenge to ensure the sustainability and safety of such systems. Particularly, the well-established technology of borehole heat exchanger-coupled ground source heat pumps is applied for the thermal exploitation of the shallow subsurface. Due to the complexity of the involved physical processes, numerical modelling proves to be a powerful tool to enhance process understanding as well as to aid the planning and design processes. Simulations can also support the management of thermal subsurface resources, planning and decision-making on city and regional scales. In this work, the so-called dual-continuum approach was adopted and enhanced to develop a coupled numerical model considering flow and heat transport processes in both the subsurface and borehole heat exchangers as well as the heat pumps’ performance characteristics, and including the relevant phenomena influencing the underlying processes. Beside the temperature fields, the efficiency and thus the consumption of electrical energy by the heat pump is computed, allowing for the quantification of operational costs and equivalent carbon-dioxide emissions. The model is validated and applied to a number of numerical studies. First, a comprehensive sensitivity analysis on the efficiency and sustainability of such systems is performed. Second, a method for the quantification of technically extractable shallow geothermal energy is proposed. This procedure is demonstrated by means of a case study for the city of Cologne, Germany and its implications are discussed. / Im Rahmen der Energiewende nimmt die Geothermie eine besondere Rolle in der thermische Gebäudeversorgung ein. Die zunehmende, intensive Nutzung oberflächennaher geothermischer Ressourcen erhöht die Gefahr der übermäßigen thermischen Ausbeutung des Untergrundes und stellt damit eine wachsende Herausforderung für die Nachhaltigkeit und Sicherheit solcher Systeme dar. Zur Erschließung oberflächennaher geothermischer Energie wird insbesondere die etablierte Technologie Erdwärmesonden-gekoppelter Wärmepumpen eingesetzt. Aufgrund der daran beteiligten komplexen physikalischen Prozesse erweisen sich numerische Modelle als leistungsfähiges Werkzeug zur Erweiterung des Prozessverständnisses und Unterstützung des Planungs- und Auslegungsprozesses. Zudem können Simulationen zum Management thermischer Ressourcen im Untergrund sowie zur Planung und politischen Entscheidungsfindung auf städtischen und regionalen Maßstäben beitragen. Im Rahmen dieser Arbeit wurde, basierend auf dem sogenannten ”dual-continuum approach” und unter Berücksichtigung des Einflusses der Wärmepumpe, ein erweitertes gekoppeltes numerisches Modell zur Abbildung der in Erdwärmesonden und dem Untergrund stattfindenden Strömungs- und Wärmetransportprozesse entwickelt. Das Modell ist in der Lage, alle relevanten Einflussfaktoren zu berücksichtigen. Neben den Temperaturfeldern im Untergrund und der Erdwärmesonde werden die Effizienz und damit der Stromverbrauch der Wärmepumpe simuliert. Damit können sowohl die Betriebskosten als auch der äquivalente CO 2 -Ausstoß abgeschätzt werden. Das Modell wurde validiert und in einer Reihe numerischer Studien eingesetzt. Zuerst wurde eine umfassende Sensitivitätsanalyse zur Effizienz und Nachhaltigkeit entsprechender Anlagen durchgeführt. Weiterhin wird ein Verfahren zur Quantifizierung des technisch nutzbaren, oberflächennahen geothermischen Potentials vorgestellt und anhand einer Fallstudie für die Stadt Köln demonstriert, gefolgt von einer Diskussion der Ergebnisse.

Page generated in 0.0387 seconds