• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da musculatura flexora de dedos a partir da análise das curvas força-tempo / Study of the flexor muscles of fingers from the analysis of the force-time curves

Gorla, Júlia Andreza 01 November 2018 (has links)
Introdução - A análise da força de preensão manual durante a força realizada ao longo do tempo fornece dados referentes ao funcionamento biomecânico dos grupos musculares, com destaque à influência da musculatura flexora profunda e superficial dos dedos, bem como traz informações pertinentes ao desempenho funcional para atividades cotidianas. Objetivos - Analisar as curvas força-tempo da preensão palmar sob os aspectos de seus parâmetros discretos e de sua característica temporal. Identificar a influência da musculatura flexora profunda de dedos na preensão palmar. Método - Os voluntários realizaram o teste de esforço isométrico máximo utilizando o dinamômetro Jamar® e o transdutor de força computadorizado com duas empunhaduras, uma que permitia a ação do músculo flexor superficial de dedos e outra que a bloqueava. Foram analisadas as curvas força-tempo geradas de 9 indivíduos tanto em seus parâmetros discretos como em suas características temporais. Resultados - A força máxima média obtida com o Jamar® na Posição 1, sem distinção entre os sexos, (30,76 Kgf) aproximou-se dos valores da média nacional para mulheres (30,4 Kgf). Tanto no teste com o Jamar® como com o transdutor de força, os valores discretos foram maiores na Posição 1 (Fmáx Jamar®: 30,76/25,14 kgf; Fmáx transdutor: 22,16/17,37 kgf; Tmáx: 1,41/1,54 seg; Finf: 7,06/5,80 kgf). A fase de manutenção da força, equivalente a força de resistência, teve menor decréscimo nos testes realizados na Posição 2 (-1,02/-0,61). Além disso, os valores obtidos entre os dinamômetros mostram que o Jamar® superestima os valores de força máxima. Conclusões - Os dados apontam que há diferença na capacidade de manutenção da força, para a qual a ação do músculo flexor profundo dos dedos mostrou-se mais eficaz do que quando em conjunto com o flexor superficial dos dedos, tendo assim, grande importância funcional para a execução das atividades de vida diária. Evidencia-se que a análise da força por meio de suas características temporais fornece maior elucidação do desempenho muscular durante a força de preensão do que testes dinamométricos pontuais. / Introduction - The analysis of the manual grip force along time presents the biomechanical movement of muscle groups data, with emphasis on the deep and superficial flexor musculature of the fingers, as well as provides relevant information for the functional performance of daily activities. Objectives - To analyze the force-time curves of the palmar grip under the aspects of its discrete parameters and its temporal characteristic. Either, to identify the the influence of the flexor muscles of fingers in the palmar grip. Method - The volunteers performed the maximum isometric effort test using the Jamar® dynamometer and the computerized force transducer with two grips, one that allowed the action of the flexor superficial finger muscle, and another that blocks it. The force-time curves generated from 9 individuals were analyzed in both their discrete parameters and their temporal characteristics. Results - The medium of maximum strength obtained with Jamar® at Position 1, without distinction between gender, (30.76 Kgf) approached the national average for women (30.4 Kgf). In both the Jamar® and the force transducer tests, the discrete values were higher in Position 1 (Fmax Jamar®: 30.76 / 25.14 kgf; Fmax transducer: 22.16 / 17.37 kgf; Tmax: 1.41 / 1.54 sec; Finf: 7.06 / 5.80 kgf). The strength maintenance phase, equivalent to the resistive force, had a smaller decrease in the tests performed in Position 2 (-1.02 / -0.61). In addition, the values obtained between the dynamometers show that the Jamar® overestimates the maximum force values. Conclusions - The data points that there is a difference between the action of the flexor profound muscle group of the fingers and the flexor superficial one in the capacity of maintaining the force, showing that the profound group is more effective than combined with the superficial flexor, thus, the first one has great functional importance for performing activities of daily life. It evidences that the analysis of force on its temporary characteristics is more elucidative of the muscular performance during the grip force than the punctual dynamometric tests.
2

Proposta metodológica para avaliação quantitativa da fase rápida da curva força-tempo na preensão manual de pacientes com doença renal crônica / Methodological proposal for quantitative assessment of the fast phase of the handgrip force-time curve with chronic kidney disease patients

Fonseca, Guilliber Carlos da 25 March 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-04T11:31:20Z No. of bitstreams: 1 guillibercarlosdafonseca.pdf: 2026851 bytes, checksum: 6ccb372126c69004827ea484ee727b78 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-10-04T12:39:27Z (GMT) No. of bitstreams: 1 guillibercarlosdafonseca.pdf: 2026851 bytes, checksum: 6ccb372126c69004827ea484ee727b78 (MD5) / Made available in DSpace on 2016-10-04T12:39:27Z (GMT). No. of bitstreams: 1 guillibercarlosdafonseca.pdf: 2026851 bytes, checksum: 6ccb372126c69004827ea484ee727b78 (MD5) Previous issue date: 2010-03-25 / A Doença Renal Crônica (DRC) é caracterizada pela perda da capacidade de filtragem dos rins. O paciente com DRC tem diminuição dos níveis de força muscular e de condicionamento físico, os quais estão diretamente ligados à qualidade de vida e à realização das atividades da vida diária. A atividade física, especificamente o treinamento de força, pode ser utilizada como uma intervenção não farmacológica para o tratamento da doença. Para a realização desse tipo de programa há a necessidade da identificação do volume e intensidade do treinamento neuromuscular, através de testes de carga. No entanto, a aplicação dos testes de carga dinâmica máxima (uma repetição máxima ou de peso por repetição) não é adequada para pacientes com DRC em razão do seu baixo nível de força muscular. Antes de se definir qual o melhor teste para avaliação da carga de treinamento, é necessário, primeiramente, identificar as características da produção da força muscular nesses pacientes. Para tanto, os testes de esforço muscular isométrico parecem ser ideais para isso, em específico o da dinamometria computadorizada de preensão da mão que, além de fácil aplicação, possibilita a avaliação do comportamento da contração muscular através da análise da curva força-tempo. Neste estudo propõe-se uma técnica para análise das curvas, em sua fase de produção de força (fase rápida) através do ajuste, por quadrados mínimos, de um modelo matemático com quatro parâmetros (a,b,c,d). A amostra foi composta de 31 pacientes com DRC (51±15 anos, 69,94±13,34 kg e 1,65±0,08 m) e 4 sujeitos hipertensos (37 ± 14 anos, 75,1 ± 16,5 kg e 1,72 ± 0,12 m), como controle. Foram utilizados os dinamômetros JAMAR (referência) e o transdutor de preensão manual computadorizado, com empunhadura modificada. Não foram observadas diferenças significativas entre os valores de força máxima dos membros dominante e não dominante, e dos parâmetros b (p = 0,18), c (p = 0,35) e d (p = 0,05). Somente os valores da pré-carga (p < 0,001) e do parâmetro a (p < 0,001) foram significativamente diferentes, o que significa dizer que o paciente com DRC inicia o teste com força inicial maior do que o grupo controle e atinge mais lentamente o valor máximo de força. Novas pesquisas baseadas em diferentes protocolos de 6 testes de esforço muscular isométrico poderão confirmar as ações específicas das unidades motoras de contração lenta e rápida em cada fase da curva força-tempo. / The chronic kidney disease (CKD) is characterized by lost in kidney filtration capacity. These patients with CKD have decreased levels of muscle strength, physical functioning, which is connected with daily activities and quality of life. The physical activity can be employed as a non pharmacologic procedure, but to programming a physical training is necessary evaluated the features to be work. The standard of evaluations must be observed to ensure pureness of datum collected. The evaluation of strength-time curve can be one methodology used to clarify the muscle contraction behavior. So, we proposed a methodology of curve analysis of patients with CKD, using non linear and linear mathematic parameter mode, which when evaluated allow us make correspondence with muscle contraction physiology. The sample was determined by 31 patients (51±15 years old, 69,94±13,34 kg e 1,65±0,08 meters) with CKD and 4 individuals with high blood pressure (37 ± 14 years old, 75,1 ± 16,5 kg e 1,72 ± 0,12 meters), they were evaluated by handgrip test in 2 moments with 2 different dynamometers. Significative differences were not observe between values of maximal strength, between members and parameters [b] (p=0,18), [c] (p=0,35) e [d] (p=0,05). Merely the values of preload (p = 0,00000014),, of [a] parameter (p=0,00078), and the values of patients strength between dynamometers were significant different: right (p = 0,00003) and left (p = 0,0001). Using the parameters of strength-time curve become a methodology with good price, non-invasive and could be applied easily in the evaluations. The necessity of new instigations employed the analysis methods is evident.

Page generated in 0.0593 seconds