Aplicação do método respirométrico em wetlands para a determinação de parâmetros cinéticos

Pereira, Ricardo Molto [UNESP] 18 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-18Bitstream added on 2014-06-13T20:59:26Z : No. of bitstreams: 1 pereira_rm_me_ilha.pdf: 1432998 bytes, checksum: 6dcb734dcd08066888b6380e4902b1a0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A presente dissertação refere-se ao trabalho experimental desenvolvido durante programa de pós-graduação strictu sensu da Universidade Estadual Paulista “Júlio de Mesquita Filho”, no qual se procurou determinar parâmetros cinéticos para dimensionamento de sistemas de alagados construídos de fluxo descendente, utilizando sistema de aeração artificial e natural. Este tema foi escolhido, pois, apesar do extenso número de trabalhos publicados sobre a aplicação do método respirométrico, muitos se referem a sistemas de lodos ativados, enquanto que para alagados construídos praticamente não existiam estudos apurados sobre o assunto. Esta dissertação contempla revisão bibliográfica de temas de elevada importância para o desenvolvimento e compreendimento dos resultados obtidos no experimento. Dentre estes temas, procurou especificar as definições de alagados construídos com suas respectivas tipificações, processos atuantes de remoção de nutrientes em filtros biológicos, e aplicação do método respirométrico para determinação de parâmetros cinéticos. Trabalhou-se estatisticamente e analiticamente os resultados obtidos no experimento, para comparar em diferentes situações físicas, hidráulicas e de carga aplicada; as respectivas eficiências de remoção de nutrientes e seus parâmetros cinéticos. Deste estudo pôde-se concluir que meio-suportes de maior área superficial, como por exemplo, a areia, apresentou maior quantidade de biomassa ativa aderida ao meio suporte, implicando em menor perda desta, durante a troca de efluente em sistema de bateladas. Já meio-suportes como pedrisco e brita, possuem menor área superficial, porém maior índice de vazios, o que implica na possibilidade de aplicação de uma carga maior quando comparado à areia. Em contrapartida, há maior perda de biomassa ativa na troca do efluente em sistemas... / This dissertation is the experimental work developed during the post-graduate program strictest sense of the Universidade Estadual Paulista Julio de Mesquita Filho, which sought to establish kinetic parameters for design of systems of constructed wetlands flow downward, using natural and artificial system aeration. This theme was chosen because, despite the extensive number of papers published on the application of the method repirometric, many refer to systems of activated sludge, while that for virtually no flooded constructed studies found on the subject. This work includes review of issues of high importance to the development and understanding of the results of the experiment. Among these issues, sought to specify the definitions of constructed wetlands with their classifying, working processes of removal of nutrients in biological filters, and the method for determining respirométrico kinetic parameters. Was statistically and analytically worked the results obtained in the experiment, to compare situations in different physical, hydraulic and applied load, the respective efficiencies of removal of nutrients and their kinetic parameters. In this study it was concluded that half of greater media surface area, such as the sand, showed greater amount of biomass attached to the active support means, resulting in loss of this, during the exchange of sewage system in batches. Already support such small and media as crushed gravel, have smaller surface area, but higher rate of empty, which implies the possibility of applying a greater load when compared to the sand. In contrast, there is greater loss of biomass in the active exchange of sewage systems in batches, implying the need for mechanisms for trapping of bacteria, such as secondary decanters.
162

Diagnóstico da qualidade e disponibilidade de água na microbacia do Córrego Água da Bomba no município de Regente Feijó - SP

Molina, Pablo Moreno [UNESP] 27 January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-01-27Bitstream added on 2014-06-13T20:59:26Z : No. of bitstreams: 1 molina_pm_me_ilha.pdf: 1455996 bytes, checksum: 5fce37211c930db3a37a554d2bf01bba (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / A Microbacia do Córrego Água da Bomba está localizada no município de Regente Feijó, Estado de São Paulo, nela inserida as zonas rural e urbana, que devido às erosões e lançamentos de águas residuárias degradam o ambiente, resultando em assoreamento dos mananciais e decrécimo de qualidade da água. Este é o preço pelo qual o Córrego Água da Bomba, assim como muitos outros mananciais, vêm pagando devido ao desenvolvimento econômico de algumas populações despreocupadas com o ambiente. Este trabalho diagnostica as condições de qualidade da água do Córrego Água da Bomba e seus afluentes, Córrego Sem Nome e Córrego do Laticínio, mananciais que recebem despejos da estação de tratamento de esgotos (ETE), construída por uma lagoa anaeróbia seguida por outra facultativa, através de determinações mensais entre 21/09/04 e 18/06/05 em 2 pontos de coletas na ETE e 5 pontos de coleta nos mananciais. Em cada local de amostragem foram determinados 'Escherichia coli', coliformes totais, demanda bioquímica de oxigênio, demanda química de oxigênio, nitrogênio total, fósforo total, temperatura, turbidez, sólidos totais, sólidos suspensos, sólidos dissolvidos e oxigênio dissolvido, calculando-se também o IQA (Índice de Qualidade das Águas). Esses dados serviram de base para propostas de melhorias na ETE e na microbacia, visando minimizar a degradação ambiental. Entre os pontos de avaliação há uma distância de 2,5 km de curso d'água, onde ocorre aumento médio de 25% da concentração de sólidos totais, passando de 173,5mg/L, sendo registrada a vazão máxima de 1.093L/s no ponto mais à jusante, tendo neste ponto média de 39.277 NMP/100mL de 'Escherichia coli' e de sólidos, o Córrego Água da Bomba apresenta uma autodepuração média de 67% da DBO (Demanda Bioquímica de Oxigênio) e em alguns pontos a contração de oxigênio dissolvido atinge até 100% da saturação. / The Água da Bomba Creek's Watershed is located in the Regente Feijó city, São Paulo State, which present agricultural and urban zones, that due to the erosions and wasted water discharges degrade the environment, resulting in rivers deposit and decrease of quality of the water. This is the price for which the Água da Bomba Creek's Watershed, as well as many other sources, comes paying due to the economic-society development of some populations not worried with the environ. This work diagnosis quality conditions of the Água da Bomba Creek and its tributaries, Sem Nome Creek and Laticínio Creek, sources that receive discharges of the Wasted Water Treatment Plant (WWTP), constituted by pounds, through monthly determination between 21/09/04 and 18/06/05 in 2 sample points in the WWTP and 5 sample points in the sources. In each sample point was determined Escherichia coli, total coliforms, biochemist oxygen demand, chemical oxygen demand, total nitrogen, total phosphorus, temperature, turbidez, total solids, suspended solids, dissolved solids and dissolved oxygen, calculating also the WQI (Water Quality Index). These data served for improvements proposals base in WWTP and in watershed, aiming minimize the environmental degradation. Among sample points there is 2.5 km along the water course, where it occurs total solid concentration average increase of 25%, varying from 173.5mg/L to 230.6mg/L, registering 1,093L/s of maxim flow at the last point of downstream, showing 39,277 NMP/100mL Escherichia coli average. However, even keeping a high level of concentration of Escherichia coli and of solid, water Stream of the Bomb introduces an average of 67% of BOD (Biochemtry Oxygen Demand) and in some points the concentration of dissolved oxygen reaches up to 100% of the saturation. Água da Bomba Creek Watershed degradation is visible, but the autodepuration creek remains active and this work shows the quarrel between pollution and autodepuration...
163

Construção de um sistema de alagados construídos e o comportamento dos parâmetros físico-químicos e biológicos da fase de maturação dos leitos de fluxo vertical

Avelino, Maria Clara Godinho Somer [UNESP] 06 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-06Bitstream added on 2014-06-13T20:59:41Z : No. of bitstreams: 1 avelino_mcgs_me_bauru.pdf: 1310267 bytes, checksum: 3759dbcf2bb00c77b6d84614fa3d81fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta dissertação de mestrado consistiu em elaborar e construir uma Estação de Tratamento de Esgoto (ETE) que utilizasse o sistema de Alagados Construídos (wetlands) para tratar o esgoto gerado no Departamento de Educação Física e da Moradia Estudantil, ambos ligados a Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP de Bauru. Para isso foi criado um sistema híbrido de fluxo subsuperficial horizontal seguido por outro de fluxo vertical, com recirculação. O projeto foi desenvolvido no campo da universidade para atender 91 habitantes equivalentes. Nesse trabalho, foram explorados as etapas construtivas da ETE e realizado análises físico-químicos e biológicos dos alagados construídos de fluxo vertical na fase de maturação do sistema. A elaboração deste estudo é uma ferramenta importante para o desenvolvimento do sistema de alagados construídos no Brasil, uma vez que, possibilita o conhecimento das técnicas de construção, manutenção e gastos para implantação de um sistema desse tipo / The realization of this research project is to develop and build a sewage treatment plant using the system of Constructed Wetlands to treat sewage generated in the Department of Physical Education and Student Housing, both linked to Universidade Estadual Paulista Julio de Mesquita Filho - UNESP in Bauru. For it was created a hybrid system of horizontal subsurface flow followed by another vertical flow, with recirculation. The project was developed at the university campus to meet 91 equivalent inhabitants. In this work were explored constructive steps ETE and testing of physico-chemical and biological of vertical flow constructed wetlands in the maturation phase of the system. The preparation of this study is an important tool for the development of constructed wetlands system in Brazil, since it enables the knowledge of construction techniques, maintenance and expenses fopr deploying such a system
164

O saneamento e as águas de Bauru : uma perspectiva histórica (1896 -1940) /

Gulinelli, Erica Lemos. January 2016 (has links)
Orientador: Nilson Ghirardello / Banca: Nilson Ghirardello / Banca: Norma Regina T. Constantino / Banca: Maria Angela Pereira de Castro e Silva Bortolucci / Resumo: O Saneamento e a questão das águas urbanas são pertinentes e importantes para as cidades na atualidade. Entendendo as origens, problemas e conflitos do passado, pode-se discutir possíveis soluções para as adversidades diárias no momento contemporâneo. Desta forma, muitas poderiam ter sido as perspectivas para analisar o percurso pela história do saneamento da cidade. Contudo, o olhar dado a esta pesquisa parte de um questionamento central: o princípio estruturador para a coleta de referências e informações, como também, serviu de base para análises ao longo do texto. Tal questão pode ser formulada assim: como se deu a trajetória histórica do saneamento na cidade de Bauru atrelada aos aspectos do desenvolvimento econômicos, sociais, políticos e culturais, no período de sua formação urbana até a década de 1940? Percebe-se que o saneamento é visto como medida higienizadora e de embelezamento do ambiente construído, com a finalidade de prevenir doenças e manter a assepsia. A infraestrutura de água e esgoto constituiu-se como um meio de minimizar as questões relacionadas com a higiene urbana da cidade. A literatura que trata a história de sanear a cidade de Bauru é fragmentada e escassa, baseada em relatos de memorialistas. Assim, opta por uma análise integrada dos setores da história urbana, do saneamento e da saúde (por meio de ações sanitárias) com a finalidade de entender sua intrínseca relação com a demanda social, embasando-a em fatos históricos e documentação primária e téc... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Sanitation and urban waters are greatly relevant and important to the cities nowadays. Understanding the origins, problems and conflicts of the past, we can discuss possible solutions for everyday adversities. The perspectives concerning to the analysis of this matter could have been done by many ways throughout the city's sanitation history. However, the overview aimed at this research is a part of a central question, which concerns to the structuring principle of collecting references and information to make it serve as basis for analysis throughout the dissertation. This hypothesis can be formulated as the question that follows: how did the historical trajectory of sanitation in the city of Bauru tied aspects of economic, social, political and cultural development, from its urban conformation in the 1940s? It is perceived that sanitation regards both to hygiene and to environmental beautification, a concept built for the purpose of prevention of diseases and asepsis. The infrastructure of water and sewage constituted a means to minimize issues related to the urban hygiene of the city. The literature on the history of cleansing up the city of Bauru is fragmented and scarce, based mainly on memoir reports. That is why this research aims to present an integrated analysis of the sectors of urban history, sanitation and health (through sanitary actions) in order to understand its intrinsic relationship to the social demand, basing it on historical facts and technical documentat... (Complete abstract click electronic access below) / Mestre
165

Diagnóstico da qualidade e disponibilidade de água na microbacia do Córrego Água da Bomba no município de Regente Feijó - SP /

Molina, Pablo Moreno January 2006 (has links)
Orientador: Fernando Braz Tangerino Hernandez / Banca: Maurício Augusto Leite / Banca: José Antônio Saldanha Louzada / Resumo: A Microbacia do Córrego Água da Bomba está localizada no município de Regente Feijó, Estado de São Paulo, nela inserida as zonas rural e urbana, que devido às erosões e lançamentos de águas residuárias degradam o ambiente, resultando em assoreamento dos mananciais e decrécimo de qualidade da água. Este é o preço pelo qual o Córrego Água da Bomba, assim como muitos outros mananciais, vêm pagando devido ao desenvolvimento econômico de algumas populações despreocupadas com o ambiente. Este trabalho diagnostica as condições de qualidade da água do Córrego Água da Bomba e seus afluentes, Córrego Sem Nome e Córrego do Laticínio, mananciais que recebem despejos da estação de tratamento de esgotos (ETE), construída por uma lagoa anaeróbia seguida por outra facultativa, através de determinações mensais entre 21/09/04 e 18/06/05 em 2 pontos de coletas na ETE e 5 pontos de coleta nos mananciais. Em cada local de amostragem foram determinados 'Escherichia coli', coliformes totais, demanda bioquímica de oxigênio, demanda química de oxigênio, nitrogênio total, fósforo total, temperatura, turbidez, sólidos totais, sólidos suspensos, sólidos dissolvidos e oxigênio dissolvido, calculando-se também o IQA (Índice de Qualidade das Águas). Esses dados serviram de base para propostas de melhorias na ETE e na microbacia, visando minimizar a degradação ambiental. Entre os pontos de avaliação há uma distância de 2,5 km de curso d'água, onde ocorre aumento médio de 25% da concentração de sólidos totais, passando de 173,5mg/L, sendo registrada a vazão máxima de 1.093L/s no ponto mais à jusante, tendo neste ponto média de 39.277 NMP/100mL de 'Escherichia coli' e de sólidos, o Córrego Água da Bomba apresenta uma autodepuração média de 67% da DBO (Demanda Bioquímica de Oxigênio) e em alguns pontos a contração de oxigênio dissolvido atinge até 100% da saturação. / Abstract: The Água da Bomba Creek's Watershed is located in the Regente Feijó city, São Paulo State, which present agricultural and urban zones, that due to the erosions and wasted water discharges degrade the environment, resulting in rivers deposit and decrease of quality of the water. This is the price for which the Água da Bomba Creek's Watershed, as well as many other sources, comes paying due to the economic-society development of some populations not worried with the environ. This work diagnosis quality conditions of the Água da Bomba Creek and its tributaries, Sem Nome Creek and Laticínio Creek, sources that receive discharges of the Wasted Water Treatment Plant (WWTP), constituted by pounds, through monthly determination between 21/09/04 and 18/06/05 in 2 sample points in the WWTP and 5 sample points in the sources. In each sample point was determined Escherichia coli, total coliforms, biochemist oxygen demand, chemical oxygen demand, total nitrogen, total phosphorus, temperature, turbidez, total solids, suspended solids, dissolved solids and dissolved oxygen, calculating also the WQI (Water Quality Index). These data served for improvements proposals base in WWTP and in watershed, aiming minimize the environmental degradation. Among sample points there is 2.5 km along the water course, where it occurs total solid concentration average increase of 25%, varying from 173.5mg/L to 230.6mg/L, registering 1,093L/s of maxim flow at the last point of downstream, showing 39,277 NMP/100mL Escherichia coli average. However, even keeping a high level of concentration of Escherichia coli and of solid, water Stream of the Bomb introduces an average of 67% of BOD (Biochemtry Oxygen Demand) and in some points the concentration of dissolved oxygen reaches up to 100% of the saturation. Água da Bomba Creek Watershed degradation is visible, but the autodepuration creek remains active and this work shows the quarrel between pollution and autodepuration... / Mestre
166

Irrigação de milho por sulcos com efluente de esgoto doméstico tratado /

Pletsch, Talita Aparecida, 1984- January 2012 (has links)
Orientador: Raimundo Leite Cruz / Banca: João Carlos Cury Saad / Banca: Antonio Evaldo Klar / Banca: Maritane Prior / Banca: Tarlei Arriel Botrel / Resumo: O reuso do efluente doméstico tratado na agricultura surge como alternativa de destino para o efluente, levando em consideração que este possui características físico-químicas que contribuem com a agricultura, ao mesmo tempo em que possui concentrações que, muitas vezes, ultrapassam os padrões adequados de lançamento nos corpos d'água. A disposição do esgoto doméstico tratado no solo aumenta a quantidade de matéria orgânica, nutrientes e ainda fornece água que a cultura necessita. Neste estudo, o efluente de esgoto doméstico tratado foi utilizado para irrigação da cultura do milho, por meio de sulcos, tendo como objetivo avaliar a interferência da água residuária na produção da cultura e nos atributos químicos do solo. Os tratamentos aplicados foram irrigação com água (TA) e irrigação com efluente de esgoto doméstico (TE). O experimento foi conduzido durante uma safra, utilizando o híbrido simples de milho DOW 2B587. Para análise agronômica da cultura, avaliaram-se a altura das plantas, altura da inserção de espiga, relação altura/inserção, comprimento das espigas com e sem palha, diâmetro das espigas com e sem palha, peso das espigas com e sem palha, peso da palha das espigas, índice de espiga e a produtividade. Os parâmetros avaliados em relação ao solo foram o fósforo (P), potássio (K), matéria orgânica (MO), enxofre (S), pH, cálcio (Ca), magnésio (Mg), soma de bases (SB), capacidade de troca de cátions (CTC), porcentagem de saturação por bases (V%), alumínio (Al3+), acidez potencial (H+Al) e os micronutrientes, cobre(Cu), ferro (Fe), manganês(Mn), zinco (Zn), boro (B), no início e final da safra, nas linhas de plantio e nos sulcos de irrigação. Os resultados obtidos demonstraram que o reúso de efluente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The reuse of treated domestic effluent in agriculture arises as alternative destination to the effluent, taking into account that it possesses physical and chemical characteristics that contribute to agriculture, while it possess concentrations that could many times exceed the appropriate standards of release into water bodies. The disposal of treated domestic sewage in the soil raises the quantity of organic matter, nutrients and the water that the culture needs. In this study the treated domestic sewage effluent was used to irrigation of corn culture, using furrows, having as objective evaluate the water waste interference on the culture production and on the soil chemical attributes. The applied treatments were with water (TA), and irrigation with domestic sewage effluent (TE). The experiment was conducted during a crop, using the simple hybrid of corn DOW 2B587.To the agronomic analysis of the culture were evaluated the plants heights, spike insertion height, ratio of height/spike insertion, spike length with and without straw, spike diameter with and without straw, spikes weight with and without straw, spike index and the productivity / Doutor
167

Estudo da variação temporal da presença de estrógenos em duas ETE do Estado de São Paulo /

Pimentel, Paulo Alexandre. January 2014 (has links)
Orientador: Mary Rosa Rodrigues de Marchi / Co-orientador: Ademir dos Santos / Banca: Alberto José Cavalheiro / Banca: Carolina Lourencetti / Banca: Laudicéia Giacometti Lopes / Banca: Fernando Fabriz Sodré / Resumo: Nos últimos anos os contaminantes emergentes presentes nos esgotos sanitários em concentrações da ordem de ng L-1 ou μg L-1 tem despertado interesse na comunidade cientifica por apresentar potencial para exercer efeitos adversos em humanos e animais. Dentre os contaminantes emergentes presentes nos esgotos sanitários, podemos citar os estrógenos naturais (17β-estradiol, estrona, estriol) e sintético (17α-etinilestradiol) os quais têm sido motivo de preocupação devido a grande quantidade lançada diariamente no ambiente, via esgotos sanitários tratados ou não. Devido à existência de poucos estudos publicados na literatura sobre a eficiência das estações de tratamentos de efluentes brasileiras na remoção dos estrógenos naturais e sintéticos, motivou a realização desta pesquisa em duas cidades do estado de São Paulo, que serão chamadas de cidade A e cidade B, ambas pertencentes às UGRHI 9 Mogi-Guaçu e a UGRHI 13 Tietê-Jacaré. Na ETE - cidade B o esgoto bruto é tratado através do Sistema Cíclico de Lodos Ativados, por batelada; e na ETE cidade A, o esgoto bruto é tratado através de um sistema misto, utilizando a tecnologia de Digestor Anaeróbio de Fluxo Ascendente e complementado com um pós-tratamento através de lagoas facultativas. A determinação dos estrógenos foi efetuada por método otimizado e validado que inclui SPE (C18) para extração e pré-concentração dos analitos em amostras de esgoto sanitário bruto e tratado (250 mL) e analise por HPLC/FLU. A exatidão apresentou valores médios acima de 71% para 17  estradiol (E2); 78% para 17  etinilestradiol (EE2); e 80% para estrona (E1), com precisão menor ou igual a 15% para as amostras fortificadas. Os limites de quantificação foram 32 ng L-1 para E2; 100 ng L-1 para EE2; e 3,2 μg L-1 para E1, para ambas as matrizes estudadas. O estudo ambiental incluiu a amostragem do esgoto sanitário bruto e tratado das ETE cidade A e cidade B, durante... / Abstract: In recent years emerging contaminants in sewage at concentrations of the order of ng L-1 or μg L-1 has aroused interest in the scientific community by presenting potential to cause adverse effects in humans and animals. Among the emerging contaminants in sewage, we can mention the natural estrogens (17 β-estradiol, estrone, estriol) and synthetic (17 α-ethinylestradiol) which have been of concern because of the large amount released daily into the environment sewage treated or not. Due to the limited studies on the efficiency of Brazilian wastewater treatment plants in the removal of natural and synthetic estrogens, motivated this research in two cities in the state of São Paulo, which will be called the city A and city B, both belonging to UGRHI 9 Mogi-Guaçu and UGRHI 13 Tietê-Jacaré. In the ETE city B raw sewage is treated Cyclic Activated Sludge System, batch; and the ETE city A, raw sewage is treated through a mixed system, using the technology of Upflow Anaerobic Digester and complemented with a treatment by facultative lagoons. The determination of estrogens was performed by optimized and validated method including SPE (C18) for the extraction and pre-concentration of analytes in samples of raw sewage and treated (250 mL) and analysis by HPLC/FLU. The accuracy showed average values over 71% for E2, 78% for EE2, and 80% for E1 with less than or equal to 15% precision for spiked samples. The limits of quantification were 32 ng L-1 for E2; 100 ng L-1 for EE2; and 3,2 μg L-1 for E1, for all matrices investigated. The environmental study includes sampling of raw sewage and treated the WWTP city A and city B for nine months. The concentrations found in raw sewage ranged from 312-2966 ng L-1 for E2; 116-1309 ng L-1 for EE2; and 16-168 μg L-1 for E1; whereas the treated sewage for the concentrations ranged from 95-1591 ng L-1 for E2; 155-4540 ng L-1 for EE2 and 5-80 μg L-1 for E1. In this study the average efficiency observed in... / Doutor
168

Bactérias potencialmente resistentes a antibióticos, desinfetantes e radiação ultravioleta, isoladas de esgoto hospitalar e esgoto sanitário

Ferreira, João Cairo 09 April 2015 (has links)
CAPES / O uso da água e seu posterior lançamento em corpos hídricos, pode ser um possível fator de disseminação de microrganismos potencialmente patogênicos e/ou resistentes. A presença destes microrganismos em águas tratadas ou não, pode representar considerável risco a saúde da população em geral e ao meio ambiente. No Brasil, segundo a legislação atual, os estabelecimentos assistenciais de saúde podem direcionar seus efluentes para a rede coletora e de tratamento de esgoto, juntamente com o esgoto doméstico. Considerando a sobrevivência dos microrganismos patogênicos lançados no esgoto hospitalar e sua permanência após os processos de tratamento, buscou-se realizar a quantificação, isolamento, identificação de bactérias ambientais oportunistas e/ou feco-orais (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), presentes em esgoto hospitalar, entrada e saída de uma estação tratamento de esgoto - ETE, além de estudar a sensibilidade destes isolados a antimicrobianos (antibióticos e desinfetantes) e exposição à radiação Ultravioleta (UV). Amostras de esgoto foram coletadas durante um período de oito meses (Maio a Dezembro de 2013), sendo realizadas analises quanto a seus parâmetros físico-químicos (DQO, Série de Sólidos, pH, Nitrogênio Amoniacal, Turbidez) e análises microbiológicas (Isolamento, quantificação e identificação), e testes de sensibilidade a antibióticos e desinfetantes mais utilizados nos hospitais brasileiros e de contatado com radiação ultravioleta. Foi constatado a existência de todos os gêneros/espécies foco deste estudo, em todos os pontos de coleta, além de resistência das bactérias aos antibióticos testados e tratamentos propostos. Um dos fatores de baixa eficiência para os tratamentos pode ser atribuída a quantidade elevada de sólidos suspensos dispersos no efluente e a crescente emergência de multirresistência para os testes de antibiograma. Estes fatores suscitam a necessidade de um maior controle pela comunidade científica e pela população em geral no que diz respeito ao impacto da presença dessas bactérias nos esgotos e posteriormente nos corpos hídricos, em seu ecossistema e a saúde pública. / The use of water and its posterior release into hydric bodies can be a possible factor of dissemination of microorganisms potentially pathogenic and/or resistant. The presence of these organisms in treated or untreated water may represent considerable threat to the general population’s health and the environment. In Brazil, according to current legislation, health assistance establishments can direct its effluents to the sewage treatment and collection network together with domestic sewage. Taking into consideration the survival of pathogenic microorganisms released in hospital sewage as well as its permanence after treatment processes, this study realized the quantification, isolation and identification of opportunistic environmental and/or fecal-oral bacteria (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), present in hospital sewage and in sewage treatment station entry and exit –ETE, and studied the sensibility of these isolated towards antimicrobials (antibiotics and disinfectants) and exposure to UV (Ultraviolet Radiation). Sewage samples were collected during a period of 8 months (from May to December 2013) to analyze their chemical-physical parameters (COD, Series of Solids, pH, Nitrogen Ammonia, Turbidity) and to carry out microbiological analyses (Isolation, quantification and identification) and sensibility tests to the most used antibiotics and disinfectants by Brazilian hospitals and in contact with UV radiation. The presence of all the species/ genus, which were the focus of this study, was detected in all collection points plus their resistance to tested antibiotics and proposed treatments. One of the low efficiency factors for the treatments were the high amount of suspended solids dispersed in the effluent and the increasing multi-resistance emergency to antibiogram tests. These factors have created the need for greater control by the scientific community and the general population in regards to the impact of the presence of these bacteria in sewages and later in hydric bodies, its ecosystem and public health.
169

Reator de leito estruturado com recirculação submetido à aeração intermitente no tratamento de esgoto sanitário / Structured bed reactor with recirculation subjected to intermittent aeration in the treatment of domestic sewage

Correa, Camila Zoe 10 December 2015 (has links)
O lançamento de compostos nitrogenados em corpos d’água pode resultar em problemas ambientais, sendo assim tratar águas residuárias, como o esgoto sanitário com o objetivo de remover não apenas matéria orgânica, mas tambémnitrogênio tem sido objeto de estudo há algumas décadas. O objetivo deste trabalho foi avaliar o desempenho de um reator de leito estruturado e fluxo contínuo, com recirculação, na remoção de matéria orgânica e nitrogênio presente em esgoto sanitário, sob diferentes ciclos de Aeração intermitente (AI) e avaliar a influência destes ciclos no desenvolvimento de bactérias nitrificantes (Bactérias Oxidadoras de Amônia – BOA e Bactérias Oxidadoras de Nitrito – BON) e desnitrificantes (DESN) aderidas (Material Suporte - MS) e em suspensão (Efluente – EF e Lodo – LD). O reator utilizado possuía volume útil de 9,4 L. Como material suporte (MS) foi utilizado espuma de poliuretano, cortada e fixada em hastes de PVC. Foram trabalhadas 3 fases de aeração (AE) e não aeração (AN) com diferentes tempos: Fase 1 (4 h AE/ 2 h AN); Fase 2 (2 h AE/ 1 h AN) e Fase 3 (2 h AE/ 2 h AN). Durante todas as fases o tempo de detenção hidráulico foi mantido em 16 h e o efluente recirculado a uma vazão de 3 vezes a vazão afluente. Foram analisados: pH, alcalinidade total, temperatura, Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Nitrogênio Kjeldhl Total (NKT), N-amoniacal – N-NH4+, nitrito- N-NO2 e nitrato- N-NO3. A concentração das BOA, BON e DESN foi determinada utilizando o Número Mais Provável.gSSV-1 (NMP.gSSVmL-1). Na Fase 1 o percentual de remoção de NKT, N-NH4+ e NT foi de 76±10%, 70±21% e 67±10% respectivamente. Na Fase 2 de 80±15% de remoção de NKT, 86±15% de N-NH4+ e 68±9% de remoção de NT e na Fase 3 de 58±20%, 72±28% e 41±6% de NKT, N-NH4+ e NT, respectivamente. A eficiência de desnitrificação nas 3 fases foi acima de 70%, indicando que no reator ocorreu o processo de Nitrificação e desnitrificação Simultânea (NDS). Os percentuais de remoção de DQOT foram de 88%±4 na Fase 1, 94%±7 na Fase 2 e 90%±11 na Fase 3. A ANOVA multivariada aplicada ao NMP.gSSV-1, indicou que houve diferença significativa (F: 20,2; p-valor <0,01) entre a concentração dos organismos analisados nos diferentes ciclos de AI. Porém as diferenças entre os NMP.gSSV-1 não depende apenas de fatores isolados e sim de quais meios, fases e grupos estão sendo analisados. Dos resultados conclui-se que o sistema foi eficiente em termos de remoção de nitrogênio e matéria orgânica, e que a fase que apresentou a maior disponibilidade de Oxigênio Dissolvido (OD) e relação C/N (Fase 2), foi a que obteve as menores concentrações efluentes de matéria orgânica e N-NH4+. Apontasse que houve diferença significativa entre a concentração (NMP.gSSV-1) dos organismos analisados (BOA, BON e DESN), porém esta diferença não depende de fatores isolados e sim de quais meios (MS, EF ou LD, fases (1, 2 ou 3) e grupos (BOA, BON e DESN) está sendo considerado. / The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.
170

Bactérias potencialmente resistentes a antibióticos, desinfetantes e radiação ultravioleta, isoladas de esgoto hospitalar e esgoto sanitário

Ferreira, João Cairo 09 April 2015 (has links)
CAPES / O uso da água e seu posterior lançamento em corpos hídricos, pode ser um possível fator de disseminação de microrganismos potencialmente patogênicos e/ou resistentes. A presença destes microrganismos em águas tratadas ou não, pode representar considerável risco a saúde da população em geral e ao meio ambiente. No Brasil, segundo a legislação atual, os estabelecimentos assistenciais de saúde podem direcionar seus efluentes para a rede coletora e de tratamento de esgoto, juntamente com o esgoto doméstico. Considerando a sobrevivência dos microrganismos patogênicos lançados no esgoto hospitalar e sua permanência após os processos de tratamento, buscou-se realizar a quantificação, isolamento, identificação de bactérias ambientais oportunistas e/ou feco-orais (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), presentes em esgoto hospitalar, entrada e saída de uma estação tratamento de esgoto - ETE, além de estudar a sensibilidade destes isolados a antimicrobianos (antibióticos e desinfetantes) e exposição à radiação Ultravioleta (UV). Amostras de esgoto foram coletadas durante um período de oito meses (Maio a Dezembro de 2013), sendo realizadas analises quanto a seus parâmetros físico-químicos (DQO, Série de Sólidos, pH, Nitrogênio Amoniacal, Turbidez) e análises microbiológicas (Isolamento, quantificação e identificação), e testes de sensibilidade a antibióticos e desinfetantes mais utilizados nos hospitais brasileiros e de contatado com radiação ultravioleta. Foi constatado a existência de todos os gêneros/espécies foco deste estudo, em todos os pontos de coleta, além de resistência das bactérias aos antibióticos testados e tratamentos propostos. Um dos fatores de baixa eficiência para os tratamentos pode ser atribuída a quantidade elevada de sólidos suspensos dispersos no efluente e a crescente emergência de multirresistência para os testes de antibiograma. Estes fatores suscitam a necessidade de um maior controle pela comunidade científica e pela população em geral no que diz respeito ao impacto da presença dessas bactérias nos esgotos e posteriormente nos corpos hídricos, em seu ecossistema e a saúde pública. / The use of water and its posterior release into hydric bodies can be a possible factor of dissemination of microorganisms potentially pathogenic and/or resistant. The presence of these organisms in treated or untreated water may represent considerable threat to the general population’s health and the environment. In Brazil, according to current legislation, health assistance establishments can direct its effluents to the sewage treatment and collection network together with domestic sewage. Taking into consideration the survival of pathogenic microorganisms released in hospital sewage as well as its permanence after treatment processes, this study realized the quantification, isolation and identification of opportunistic environmental and/or fecal-oral bacteria (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), present in hospital sewage and in sewage treatment station entry and exit –ETE, and studied the sensibility of these isolated towards antimicrobials (antibiotics and disinfectants) and exposure to UV (Ultraviolet Radiation). Sewage samples were collected during a period of 8 months (from May to December 2013) to analyze their chemical-physical parameters (COD, Series of Solids, pH, Nitrogen Ammonia, Turbidity) and to carry out microbiological analyses (Isolation, quantification and identification) and sensibility tests to the most used antibiotics and disinfectants by Brazilian hospitals and in contact with UV radiation. The presence of all the species/ genus, which were the focus of this study, was detected in all collection points plus their resistance to tested antibiotics and proposed treatments. One of the low efficiency factors for the treatments were the high amount of suspended solids dispersed in the effluent and the increasing multi-resistance emergency to antibiogram tests. These factors have created the need for greater control by the scientific community and the general population in regards to the impact of the presence of these bacteria in sewages and later in hydric bodies, its ecosystem and public health.