• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 10
  • 9
  • 8
  • 8
  • 4
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 476
  • 201
  • 145
  • 123
  • 105
  • 102
  • 98
  • 98
  • 89
  • 85
  • 68
  • 64
  • 63
  • 59
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Adequação de um lisimetro de sucção para monitoração da agua do solo em saneamento

Pansani, Alexandre 18 January 2001 (has links)
Orientador: Dirceu Brasil Vieira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T03:46:49Z (GMT). No. of bitstreams: 1 Pansani_Alexandre_M.pdf: 6831438 bytes, checksum: e77e6b134ac5b72897a8fc86662d6d22 (MD5) Previous issue date: 2001 / Resumo: A preservação dos recursos hídricos e uma questão de sobrevivência da humanidade, sendo uma das grandes preocupações das lideranças políticas,científicas e acadêmicas.No entanto, é preciso adequar a monitoração destes recursos à realidade brasileira, usando equipamentos de fácil operação e baixo custo, Pode-se citar, por exemplo, os lisimetros de sucção, considerados como viável e compatível Os lisimetros de sucção são constituídos por um tubo de PVC e uma cápsula porosa,sendo que no Brasil são confeccionadas e comercializadas somente cápsulas porosas de cerâmica. Contudo, neste trabalho, foram monitorados lisimetros de sucção desenvolvidos com cápsulas porosas de cerâmica e outros materiais. Os lisimetros de sucção foram instalados em um reservatório com água, e amostras foram coletadas em um intervalo de tempo determinado,sob variações do vácuo aplicado.Posteriormente,os mesmos .foram instalados em um recipiente com solo, com adição de um volume determinado de água coletada no lago da Praça Hermógenes F. Leitão Filho, conhecido como "lago da Unicamp", onde também foram coletadas amostras em um intervalo de tempo determinado, sem variação do vácuo aplicado. Estas amostras ,de águas 'coletadas foram avaliadas -em relação aos aspectos quantitativos: volume coletado e qualitativos: .pH, condutividade elétrica, DQO e fósforo. Os resultados obtidos recomendaram a utilização do lisimetro de sucção confeccionado com cápsula porosa de plástico sintetizado, a instalação dos lisímetros de sucção de maneira invertida no solo e a não utilização do lisímetro de sucção confeccionado com cápsula porosa de cerâmica na determinação da condutividade elétrica e fósforo / Abstract: The preservation of water resource is a question of surViva1 of -humanity,being one ofgreat preocupations os leadership politics, scientifics and academics. Nevertheless,is necessary to adapt the monítoring this resources of a brazílian reality, using equipments of easy operation and cost lous. For example, the lysimeters the succtíon are constitutíve for a PVC pipe and a porous capsule, being that -in Brazil are make and comercialize always porous capsule of ceramics. However, in this work, are to going monitorate lysimeters the sucction developed with porous capsule of ceramícs and others materials. The lysimeters the succtíon are .going to collect in the range time determinate, under variations of vacuum aplicate. Posteriorly, the same are going to Install in the recipient eith soil, with adition " the determinate volume of water collect of "lake 'of {Unicamp", where are going to collect samples in the range time determinate too, without variation of evaluate in relation a quantitatives aspects: volume collect and qualitatives: pH electrical conductivity, COD and phosphorus. The gotten results had recomended the use of the lyslmeters the sucction confectioned With porous sintery plastic capsule, the Installation of the tysimeters the sucction in inverted way in the -ground and not the use of the lysimeters the succtíon confectioned with porous ceramic capsule in the determination of COD and phosphorus / Mestrado / Recursos Hidricos / Mestre em Engenharia Civil
182

Preservação de efluentes para analise de carbono organico dissolvido

Galrão, Divanildes da Silva 03 August 2018 (has links)
Orientadores: Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T19:05:03Z (GMT). No. of bitstreams: 1 Galrao_DivanildesdaSilva_M.pdf: 1700452 bytes, checksum: 00008e31bdce85af5b908dfa92cf19fd (MD5) Previous issue date: 2003 / Mestrado
183

Desempenho de leitos cultivados ("constructed wetland") para tratamento de esgoto : contribuições para concepção e operação

Valentim, Marcelus Alexander Acorinte 03 August 2018 (has links)
Orientador: Denis Miguel Roston / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-03T21:49:44Z (GMT). No. of bitstreams: 1 Valentim_MarcelusAlexanderAcorinte_D.pdf: 2457876 bytes, checksum: 040f979218083adc34549bc310f7b206 (MD5) Previous issue date: 2003 / Doutorado
184

Avaliação experimental para melhoria da eficiência da Ete do Conjunto Habitacional Ignez Andreazza em Areias (Compesa) através de estudo em Escala Piloto

SILVA, Maria de Fátima Barbosa da January 2005 (has links)
Made available in DSpace on 2014-06-12T18:07:06Z (GMT). No. of bitstreams: 2 arquivo7865_1.pdf: 950809 bytes, checksum: 017c08f8a7e33fa61e9eb18bba06f0e7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Devido ao interesse social e ambiental em se expandir o número de comunidades atendidas por sistemas de esgotamento sanitário, constitui-se também um desafio projetar, construir e operar estações de tratamento eficientes e econômicas. Com base nesses argumentos e através de análises preliminares, escolheu-se para estudo, uma estação de tratamento de esgotos domésticos operada pela COMPESA que atende a aproximadamente 12.320 habitantes residentes no Conjunto Habitacional Ignez Andreazza, o maior da América Latina, situado em Areias-Recife-PE. Nesta estação de tratamento de efluentes (ETE) foi observado um baixo rendimento na remoção da Demanda Bioquímica de Oxigênio (DBO) em relação ao esperado em projeto, assim como problemas de recirculação e de baixa concentração de lodos ativados no tanque de aeração. Desta forma, este trabalho contribuiu para a melhoria do funcionamento desta ETE a partir de informações de monitoramento da mesma e estudos em unidades piloto. Foi realizada inicialmente uma avaliação através da caracterização dos efluentes e afluentes da mesma, utilizando a metodologia do Standard Methods for Water and Wastewater Examination (APHA et al., 1985). Foram analisados três pontos do sistema: entrada após a caixa de areia, o tanque de aeração e a saída do decantador. Em seguida foi realizado um estudo do processo de tratamento em uma unidade piloto constituída de um tanque de 21 litros, dotado de aeração por pedras porosas e um decantador, ambos de acrílico. A recirculação do lodo e a alimentação do substrato sintético foram realizadas utilizando uma bomba peristáltica. Foi também realizada uma avaliação do regime de escoamento nesta unidade piloto, através da técnica de DTR utilizando NaCl como traçador. Uma análise da influência da recirculação na performance do sistema pode ser realizada através de um segundo monitoramento dos mesmos pontos e tomando como base os resultados do primeiro estudo. A avaliação da cinética foi baseada em dados obtidos por respirometria, da degradação da matéria orgânica. Foi observada uma redução de 75% dos sólidos totais dissolvidos e uma remoção da DQO de cerca de 80%. No estudo no reator piloto, foi constatado um tempo de residência médio (tm) de 8,15h com variância (σ2) de 50,35 h2 para um tempo de retenção hidráulico teórico (TRH) de 10,5h. Aplicando-os no modelo de tanques em série, verificou-se que seriam necessários dois tanques ideais em série para modelar o reator real. Na operação do sistema piloto com a biomassa, após a estabilização do sistema, foram verificados valores de eficiências de 90 e 92% para a DBO e DQO respectivamente. No estudo cinético, foram utilizados como parâmetros a DQO e em seguida a concentração de biomassa. Devido a problemas de homogeneidade e representatividade na amostragem foi utilizada a técnica da determinação da Taxa de Consumo de Oxigênio (TCO) para se monitorar o avanço da degradação. Seis experimentos para determinação da TCO permitiram obter gráficos da TCO versus tempo, encontrando-se pelo método de cálculo integral um valor médio para a constante de velocidade (k) igual a 2,6, tendo sido considerado a reação como de 1ª ordem. Como reflexo do trabalho de monitoramento, a ETE estudada superou a eficiência de remoção de DBO estimada em projeto (94%) para 96% uma vez ativada a recirculação de lodo para o tanque aerado e realizadas as modificações sugeridas
185

Avaliação do desempenho de filtros anaerobicos com diferentes meios de enchimento no tratamento de esgotos sanitarios

Couto, Luiz Carlos Costa 07 July 1998 (has links)
Orientador: Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-24T00:21:54Z (GMT). No. of bitstreams: 1 Couto_LuizCarlosCosta_M.pdf: 2178134 bytes, checksum: f1c9fc8f18acd6ab714207b8a585f6f2 (MD5) Previous issue date: 1993 / Resumo: o objeto geral deste estudo foi a aplicação do sistema de filtroanaeróbio com fluxo ascendente para o tratamento de esgotos sanitários, verificando-se a eficiência através da utilização de três tipos diferentes de enchimento: anel de polipropileno,pedra britada e anel de bambu. o objetivoespecíficoera avaliarumsistema alternativo de tratamento de esgotos coma utilização de um material de baixo custo, no caso o bambu. Foram construídos três reatores preenchidos com os meios de enchimento mencionados e alimentados com esgoto doméstico gradeado e pré-tratado em uma peneira estática, proveniente de uma região central da cidade de Campinas, Estado de São Paulo. Os parâmetros utilizados para acompanhamento foram: OSO; 000; pH; alcalinidade; e sólidos totais e suspensos, fixos e voláteis. Foram testados os seguintes tempos de detenção hidráulicos: 24, 12,8 e 4 horas. As principais conclusões da pesquisa foram: eficiência dos filtrosanaeróbios na faixa de 60 a 80 porcento em termos de remoção de OSO e 000; eficiência de 70 a 80 porcento de remoção de sólidos suspensos; tempo de detenção hidráulico deve ser maior ou igual a 8 horas; e finalmente, o filtro anaeróbio com anéis de bambu apresentou eficiência equivalente aos demais, o que o torna uma opção viável para o tratamento de esgotos sanitários / Abstract: The general objetive of this study was the application of the upflow anaerobic filter to the treatment of sanitary wastewater. Efficiency was verified through the utilization of the three different packing media: pall-rings, rocks, and bamboo rings. The especific objetive was to evaluate an alternative system for wastewater treatment, utilizing a low cost packing material, namely the bamboo. For this purpose three reactors were built, and fed with screened wastewater from the central area of the city of Campinas, State of São Paulo. The parameters monitored during the experiment were: 800; COO: pH; alkalinity; and suspended and total solids, both fixed and volatile. The following hydraulic detention times were used: 24, 12, 8 and 4 hours. The most important conclusion were: anaerobic filters efficiencies were in the range of 60 to 80 percent; suspended solids removal varied from 70 to 80 percent; hydraulic detention time must be greater or equal to 8 hours; and finally, the anaerobic filters packed with bamboo rings presented treatment efficiency equivalent to the results obtained with other packing materiais reactors, showing that it is a viable option to sanitary wastewater treatment / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
186

Percepção de diferentes atores sociais sobre os impactos ambientais causados pelos desvios de esgotos sanitários em Campina Grande-PB: uma contribuição a ações sustentáveis em saneamento.

BENICIO, Maria de Fátima Fernandes Pereira. 20 September 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-09-20T13:08:41Z No. of bitstreams: 1 MARIA DE FÁTIMA FERNANDES PEREIRA BENICIO - DISSERTAÇÃO (PPGRN) 2011.pdf: 5329919 bytes, checksum: fe005bdd582212b51031838680689ebe (MD5) / Made available in DSpace on 2018-09-20T13:08:41Z (GMT). No. of bitstreams: 1 MARIA DE FÁTIMA FERNANDES PEREIRA BENICIO - DISSERTAÇÃO (PPGRN) 2011.pdf: 5329919 bytes, checksum: fe005bdd582212b51031838680689ebe (MD5) Previous issue date: 2011-03-02 / A falta de investimentos em sistemas de esgotamento sanitários e na sua manutenção tem como conseqüência a depreciação das unidades existentes, o sucateamento dos equipamentos instalados, vulnerabilidade operacional do sistema e o desvio de esgotos sanitários ao longo do seu percurso: do emissário a Estação de Tratamento de Esgotos- ETE. O objetivo deste trabalho foi avaliar a percepção de diferentes atores sociais dos impactos causados pelos desvios de esgotos sanitários dos emissários até a estação de tratamento em Campina Grande-PB. A pesquisa foi realizada de Março de 2009 a dezembro de 2010, com cinco categorias; funcionários da CAGEPA- Companhia de Água e Esgoto da Paraíba, professores pesquisadores de duas universidades públicas, agentes comunitários de saúde, professores da rede estadual e municipal e atores sociais da comunidade da Catingueira. Os dados foram coletados através de entrevistas semi-estruturada, observação participante e aplicação de estratégias de sensibilização: apresentação e discussão do projeto; realização de seminário, apresentação e discussão dos resultados obtidos, exposição de fotos dos desvios de esgotos e realização de seminários. Para análise dos dados foi utilizada a triangulação, a qual consistiu de análise qualitativa e quantitativa. Constatou-se que ao longo dos emissários e interceptores há intervenção por parte dos moradores próximo à ETE, provocando o uso dos esgotos in natura, principalmente para irrigação, causando diversos impactos socioambientais, dentre os quais: poluição, contaminação, riscos à saúde ambiental e humana. Os atores sociais da CAGEPA que fizeram parte desta pesquisa reconhecem que existe esta prática (100%), e mostraram-se preocupados quanto aos desvios e aos impactos. A maioria dos especialistas em recursos hídricos e saneamento investigada apresentou conhecimento dos desvios de esgotos (58%) e expressou preocupação, com uso de esgotos sem tratamento, devido às possibilidades de poluição e contaminação. As famílias estudadas (73%), os professores (60%) e os agentes comunitários de saúde (55,6%) também sabem da existência dos desvios de esgotos, embora sejam omissos ao problema, por não perceberem os danos acarretados ao meio ambiente e ao ser humano. Dentre as estratégias delineadas em Educação Ambiental, destacaram-se: exposição do projeto à comunidade; realização de seminários e apresentação dos resultados referentes ao diagnóstico socioambiental aos atores sociais envolvidos na pesquisa. As estratégias aplicadas motivaram reflexão a respeito da problemática estudada e impulsionou busca de soluções, especialmente por parte da CAGEPA, porém não propiciou mudanças significativas, uma vez que a problemática requer implantação de políticas públicas voltadas à manutenção do sistema de esgotamento sanitário; fiscalização e criação de programas de Educação Ambiental nas modalidades formais e não formais. / The lack of investments on sanitary sewage systems and its maintenance have as a consequence the depreciation of the existing units, the disposal of the installed equipment, the operational vulnerability of the system and the sewage detours throughout its path: from the emitter to the Sewage Treatment Station (ETE). The goal of the current paper is to evaluate the perception of different social actors which are related to the impacts caused by the detours on sanitary sewage detours from the emitters to the purification plants in Campina Grande-PB.The research was conducted from March, 2009, to December 2010. Five categories took part on the research: CAGEPA (Paraíba‟s Water and Sewage Company) employees, faculty members (researchers) from two different public universities, communitarian health agents, faculty members from both, city and state schools, and social actors, part of the Catingueira community. The data was collected through semi-structured interviews, participant observation and through application of awareness strategies: presentation e debate about the project; seminars, the presentation and debates regarding the results obtained; exposition of sewage detours‟ photos. In order to do so the qualitative and quantitative analysis were used. It was seen that throughout the path which goes from emitters to receivers there are interventions done by the locals in the area nearby the ETE, which result in the use of in natura sewages, especially those used in irrigation, causing several different impacts both social and environmental, which result in risks to the environmental preservation and human health. CAGEPA‟s social actors admitted (100% of those who took part in this research) the existence of the detours, and are worried about the situation, mostly about the impacts that such detours can result on. Most (58%) of the experts on hydric resources, as well as purification and treatment, were also aware of the detours and rather concerned with the non-treated sewage use, due to the possibilities of pollution and contamination. The families (73%), the teachers (60%) and the communitarian health agents (55.6%) that took part in the research are also aware the existence of sewage detours, even though they do not deal with the issue. Amongst the strategies shown on Environmental Education, the following are worth special mention: showing the project to the local community; seminars and presentation of results regarding the results of the socio-environmental diagnosis to the social actors that were part of the research. The applied strategies motivated reflection about our study and propelled the search for new solutions, especially by CAGEPA, although it has not shown any significant changes so far, as the matter requires public policies that deal with the sanitarian sewage; the creation and supervision of Environmental Education programs, both formal and non-formal.
187

Estudo hidrogeoquímico, sedimentológicos e dos foraminíferos de áreas submetidas a esgotos domésticos e petroquímicos do canal de São Sebastião, SP

Teodoro, Andreia Cristiane 12 September 2011 (has links)
O presente estudo teve por objetivo analisar a influência da disposição oceânica de esgotos domésticos e petroquímicos na coluna d\'água, nos sedimentos e nas associações de foraminíferos bentônicos. Para atingir tal objetivo foram coletadas amostras próximo aos emissários do Araçá, do Saco da Capela e do Terminal Petrolífero Almirante Barroso (TEBAR), em 2005 e 2006. Coletou-se também 10 amostras ao longo do Canal de São Sebastião, SP, em 2008. Em cada ponto amostral foram obtidos dados físico-químicos da coluna d\'água, sedimentológicos (granulometria, Cot, N, P e S) e das associações de foraminíferos. As biocenoses e tanatocenoses foram estudadas separadamente. Os resultados das análises hidrogeoquímicas não demonstraram alterações de origem antrópica. Os valores de todos os parâmetros analisados estiveram dentro dos limites estabelecidos pelo CONAMA. Os resultados das análises granulométricas e geoquímicas indicaram dois setores distintos no Canal de São Sebastião, um na região norte, com sedimentos arenosos e teores baixos de Cot, N, P e S e outro na região central, com predominância de sedimentos finos e teores elevados Cot, N, P e S. Na região central verificou-se abundância significativa de espécies euribiontes. Segundo os resultados granulométricos e geoquímicos obtidos para a região do Saco da Capela, o estresse ambiental decorrente do esgoto disposto ocorre de forma pontual, i.e. na saída do emissário submarino. As associações de foraminíferos são compostas predominantemente por espécies típicas de ambientes bem oxigenados. O emissário do Araçá está posicionado em região com circulação de fundo oscilando entre moderada e fraca. Os resultados geoquímicos indicaram enriquecimento orgânico, decorrente do efluente disposto, na região nordeste. Nesta região foram obtidas as maiores abundâncias de espécies euribiontes, com declínio de espécies estenobióticas. Pelas tanatocenoses de Setembro de 2006, constatou-se grau elevado de estresse na saída do emissário (estação Ar1), onde ocorreu dominância de foraminíf eros aglutinantes, sendo observados sinais de dissolução em espécimes hialinos. A região circundante ao emissário do TEBAR é a que apresenta maior nível de degradação ambiental. Nesta região os sedimentos são predominantemente lamosos, com elevados teores de Cot, N, P e S. As condições redutoras dos sedimentos de fundo são observadas pelos valores negativos de Eh, pelo valor levemente ácido de pH e pelos valores baixos das razões C/S. As associações de foraminíferos são compostas dominantemente por espécies bioindicadoras de ambientes hipóxicos. Os estudos comparativos (NMDS, MANOVA e teste t) evidenciaram diferenças significativas nas estruturas composicionais quando as biocenoses e tanatocenoses são comparadas entre si, bem como quando as biocenoses são comparadas com as tanatocenoses. Pelos resultados obtidos verificou-se que as interpretações seriam diferentes das obtidas, caso os estudos de avaliação ambiental fossem realizados com a associação total de foraminíferos (vivos + mortos). Palavras-chave: emissário submarino, esgotos domésticos, esgotos petroquímico / The influence of oceanic disposal of domestic and petrochemical effluents on physicochemical parameters of the water column, geochemistry of sediments and foraminiferal assemblages was assessed in this study. Water and sediment samples were collected near Araçá, Saco da Capela and Almirante Barroso Terminal Petroliferous (TEBAR) outfalls, in the São Sebastião Channel, São Paulo, Brazil, in 2005 and 2006. Ten other samples distributed along the channel were collected in 2008. For each water sample physicochemistry analyses were carried out. In the sediments, grain size, geochemistry (TOC, N, P and S) and foraminiferal co mposition were analyzed. Live and dead benthic foraminiferal composition and distribution were studied separately. The water column analyses did not demonstrate human-induced changes. The values of almost all parameters were within the National Environmental Council (CONAMA) limits. Grain size analysis and geochemistry results indicated two different morphosedimentary sectors in the São Sebastião Channel, one in the north with sandy sediments and low TOC, N, P and S, and the other in the central region wit h predominantly fine sediments, significant nutrient, TOC and S values. The Saco da Capela submarine outfall is positioned in high hydrodynamic environment. Geochemical results indicated that the environmental stress occurs only at the outfall end (station Ar1). The foraminiferal assemblage is composed of species typical of well-oxygenated bottom waters and low organic content. The Araçá submarine outfall is located in an area with moderate to weak bottom circulation. Organic enrichment due the domestic effluent disposal was observed in the southeast and northeast area, mainly by P and S and, to a lesser extent, by TOC values. In these regions opportunistic foraminiferal species dominate and stenobiotic species are absent or present in diminished values. The highest level of environmental degradation was registered in September, 2006, when dominance of agglutinated shells and signals of dissolution in hyaline shells were observed in the thanatocenosis. The area around TEBAR diffusers presents high levels of environmental stress. In this area, characterized by muddy sediments, the highest TOC, N, P and S contents were registered in all the periods were found. Reducing conditions in the region are demonstrated by values of Eh, acid pH and low C/S ratios. In the foraminiferal assemblage, environmental degradation was inferred by the dominance hypoxic species. Comparative studies (NMDS, MANOVA and t test) indicated significant differences in foraminiferal composition among biocenosis, among thanatocenosis and between biocenosis and thanatocenosis. These results demonstrate that biocenosis and thanatocenosis must be studied separately.
188

O lixiviado dos aterros sanitários em estações de tratamento dos sistemas públicos de esgotos / The leachate from landfill in wastewater treatment systems public sewers

Bocchiglieri, Miriam Moreira 11 May 2010 (has links)
O presente trabalho discute o recebimento de lixiviado de aterros sanitários em estações de tratamento do sistema público de esgotos para tratamento conjunto. Descreve os processos de geração do lixiviado nos aterros e faz uma avaliação desse recebimento em quatro estações de tratamento em operação no Estado de São Paulo que empregam processos biológicos de tratamento por lodos ativados convencional e por batelada, lagoas de estabilização (anaeróbia seguida de facultativa) e lagoas aeradas. Também apresenta a variação da produção de lixiviado em aterros sanitários em função dos períodos de chuva e seca, estabelecidos pela precipitação observada no período avaliado. Conclui que o tratamento conjunto de lixiviado de aterro é uma alternativa a ser considerada no planejamento dos sistemas de resíduos sólidos e de esgotos sanitários. A adoção do tratamento conjunto traz benefícios a esses sistemas e à sociedade, pois pode representar economia de escala, atendimento às exigências legais e conformidade ambiental, promovendo melhores condições de saúde pública / This work discuss the receipt of sanitary landfill leachate by public wastewater treatment plants for joint treatment. It describes the processes theough which leachate is generated in landfills and assesses its receipt in four wastewater treatment plants in the state of São Paulo that employ biological processes such as conventional and batch activated sludge and stabilization ponds (anaerobic pond followed by facultative pond). Additionally, the work shows the variation in the production of leachate during the dry and rainy seasons, which were established based on the volume of rainfall during the period of study. The conclusion is that the joint treatment of landfill leachate by wastewater treatment plants with the appropriate technical and operational criteria is na alternative to be considered in the planning of solid waste and sanitary sewer systems and the society because it would result in economy of scale, compliance with legal and environmental legislation, and improvement of public health
189

Desenvolvimento de sistemas de controle ótimo para a operação de processos aeróbios de tratamento de esgotos / Development of optimal control system for the operation of aerobic wastewater treatment processes

Reis, José Antonio Tosta dos 17 January 2003 (has links)
Neste trabalho, a partir da aplicação da teoria de controle ótimo, são estabelecidos sistemas de controle aplicáveis a três importantes sistemas aeróbios de tratamento de esgotos - filtros biológicos, processos de lodos ativados e os processos combinados formados a partir da combinação dos filtros biológicos e lodos ativados. Para a definição dos sistemas de controle são necessários modelos dinâmicos que descrevam o comportamento dos diferentes sistemas de tratamento. Da literatura são obtidos os modelos dinâmicos destinados à descrição do comportamento do processo de lodos ativados; para o filtro biológico, é proposto um modelo combinando à equação de balanço do reator e o modelo de ordem variável, este último destinado ao cálculo do fluxo de substrato para o interior de biofilmes profundos. Os resultados demonstram que, independentemente do sistema de tratamento considerado, os sistemas de controle reduzem substancialmente os tempos de acomodação e os desvios apresentados pelas variáveis de estado em relação as suas condições de equilíbrio. Por fim, função da inviabilidade de monitoramento de todas as variáveis de estado utilizadas para caracterizar os sistemas de tratamento, são propostos, a partir de modelos simplificados, controladores que incorporam a observação de estados. Também neste caso, os controladores estabelecidos permitem melhorar significativamente o desempenho dos sistemas de tratamento de esgotos analisados. / This paper constructs automatic control systems by means of optimal control theory for three different combinations of wastewater treatment units, namely, trickling filter, activated sludge process and a combined process. The dynamic model for the activated sludge process available in literature and a model proposed for the trickling filter were used in the construction of control systems. It is shown that the controls obtained in this study substantially reduce the durations necessary for the reestablishment of the equilibrium conditions in terms of state variables and the attenuation of oscillations around these conditions. Controls including observers for the state variables were devised on the basis of simplified models for the process in order to deal with the difficulties involved in monitoring all the state variables. These control systems were also found to be quite effective in improving the performance of the wastewater treatment plants considered in this paper.
190

O lixiviado dos aterros sanitários em estações de tratamento dos sistemas públicos de esgotos / The leachate from landfill in wastewater treatment systems public sewers

Miriam Moreira Bocchiglieri 11 May 2010 (has links)
O presente trabalho discute o recebimento de lixiviado de aterros sanitários em estações de tratamento do sistema público de esgotos para tratamento conjunto. Descreve os processos de geração do lixiviado nos aterros e faz uma avaliação desse recebimento em quatro estações de tratamento em operação no Estado de São Paulo que empregam processos biológicos de tratamento por lodos ativados convencional e por batelada, lagoas de estabilização (anaeróbia seguida de facultativa) e lagoas aeradas. Também apresenta a variação da produção de lixiviado em aterros sanitários em função dos períodos de chuva e seca, estabelecidos pela precipitação observada no período avaliado. Conclui que o tratamento conjunto de lixiviado de aterro é uma alternativa a ser considerada no planejamento dos sistemas de resíduos sólidos e de esgotos sanitários. A adoção do tratamento conjunto traz benefícios a esses sistemas e à sociedade, pois pode representar economia de escala, atendimento às exigências legais e conformidade ambiental, promovendo melhores condições de saúde pública / This work discuss the receipt of sanitary landfill leachate by public wastewater treatment plants for joint treatment. It describes the processes theough which leachate is generated in landfills and assesses its receipt in four wastewater treatment plants in the state of São Paulo that employ biological processes such as conventional and batch activated sludge and stabilization ponds (anaerobic pond followed by facultative pond). Additionally, the work shows the variation in the production of leachate during the dry and rainy seasons, which were established based on the volume of rainfall during the period of study. The conclusion is that the joint treatment of landfill leachate by wastewater treatment plants with the appropriate technical and operational criteria is na alternative to be considered in the planning of solid waste and sanitary sewer systems and the society because it would result in economy of scale, compliance with legal and environmental legislation, and improvement of public health

Page generated in 0.0307 seconds