Desenvolvimento de métodos para decomposição de coque de petróleo e posterior determinação de elementos terras raras

Kellermann, Katherine January 2016 (has links)
Neste trabalho é proposta a determinação de elementos terras raras (REE) em coque de petróleo por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES), após diferentes métodos de preparo de amostra. Para decomposição por via seca, foram avaliadas diferentes temperaturas para o procedimento (800 a 1100 ºC) e quantidade de amostra (0,5 e 2 g). Todas estas condições se mostraram adequadas para aplicação do método e foi necessária uma etapa de filtração previamente as determinações por ICP OES. Para a decomposição por via úmida assistida por radiação micro-ondas (MAWD), parâmetros como a massa de amostra (250, 375 e 500 mg) e uso de HNO3, associado ou não ao H2O2, foram avaliados. Foi observado que a adição de H2O2 não melhorou consideravelmente a decomposição da amostra (verificada pela determinação do teor de carbono residual nos digeridos) quando 375 mg de amostra foram decompostos e por isso este reagente não foi empregado em estudos posteriores. A aplicação do método MAWD exigiu a diluição da solução da amostra (pelo menos 2 vezes) para atenuar interferências na etapa de determinação por ICP OES. Para avaliação da combustão iniciada por micro-ondas (MIC) foram estudadas diferentes concentrações de HNO3 como solução absorvedora (2,3, 4,7 e 7,0 mol L-1) e massas de amostra (200, 375 e 500 mg). Com uso da MIC resultados similares foram obtidos segundo a análise de variância (ANOVA) ao nível de confiança de 95%, entre as soluções absorvedoras avaliadas. Para 200 mg, foram encontrados resultados mais concordantes com os anteriormente obtidos por outros métodos. Dos quatorze elementos estudados, apenas as concentrações de La e Ce nas amostras de coque de petróleo eram maiores que os limites de quantificação dos métodos utilizados. Em relação à etapa de determinação por ICP OES, parâmetros como potência do plasma e vazão do gás de nebulização para diferentes nebulizadores (com e sem sistema de dessolvatação do aerossol) foram otimizados, sendo que o nebulizador com sistema de dessolvatação foi capaz de reduzir em, aproximadamente, cinco vezes os limites de detecção. Além disso, foram investigadas algumas possíveis interferências e a adequabilidade da calibração por padronização interna. A exatidão dos resultados foi avaliada por meio de ensaios interlaboratoriais e comparação dos resultados obtidos com os anteriormente encontrados mediante análise por ativação neutrônica. / In this work, the determination of rare earth elements (REE) is proposed in petroleum coke samples by inductively coupled plasma atomic emission spectrometry (ICP OES) after several sample preparation methods. For sample digestion by dry ashing, variable temperatures (800 to 1100 ºC) and sample mass (0.5 to 2 g) were investigated. All operational conditions evaluated were suitable for sample digestion and it was necessary to apply a filtration step previous analytes determination by ICP OES. For microwave-assisted wet digestion (MAWD) parameters as sample mass (250, 375 and 500 mg) and the use of HNO3, combined or not with H2O2 were evaluated. It was observed that the use of H2O2 did not change the efficiency of sample digestion (verified by the residual carbon content in digests) when 375 mg of sample were digested and due this, this reagent was not used in further studies. The use of this method (MWAD) requires a dilution step (at least 2 times) to minimize interferences in determination step by ICP OES. For evaluation of microwave-induced combustion (MIC) method variable concentration of HNO3 was investigated as absorbing solution (2.33, 4.67 and 7.00 mol L-1) and sample mass (200, 375 and 500 mg). Similar results (ANOVA, confidence level of 95%) were obtained for all absorbing solutions evaluated and the sample mass of 200 mg presented better agreement with results obtained by other sample preparation methods. Among the analytes investigated, only La and Ce were quantified in the petroleum coke samples using the sample preparation methods evaluated. Regarding the analytes determination by ICP OES, parameters as radiofrequency power and nebulization gas for different nebulizers (with and without desolvation system) were optimized and the nebulizer with desolvation system was capable to reduce the limits of detection, at least, five times. Additionally, some possible interferences and the suitability of the internal standardization procedure for calibration were investigated. The accuracy of results was evaluated by comparison with results obtained with those informed by other laboratory and by neutron activation analysis.
22

Desenvolvimento de métodos analíticos para a determinação de lantanídeos por técnicas de espectrometria atômica com plasma indutivamente acoplado

Bentlin, Fabrina Regia Stumm January 2012 (has links)
Neste trabalho foram desenvolvidos métodos analíticos para a determinação de lantanídeos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massa com fonte de plasma indutivamente acoplado (ICP-MS) em diferentes tipos de matrizes: cinza de carvão, sedimento de rio, sedimento do Tibet, fluorita, pilha recarregável do tipo NiMH, água do mar, água doce e vinho tinto. Três diferentes nebulizadores foram investigados para a introdução da amostra no plasma (os nebulizadores microconcêntrico, ultrassônico e pneumático com dessolvatação do aerossol foram comparados). Nas determinações por ICP OES foram monitoradas, pelo menos, duas linhas espectrais por elemento e avaliadas a vazão do gás de nebulização e potência de radiofrequência. Dependendo da matriz da amostra, linhas espectrais adicionais foram monitoradas, devido a interferências da matriz. A vazão do gás de nebulização e a potência de radiofrequência aplicada ao plasma foram variadas conforme o elemento medido e o nebulizador utilizado, tanto para ICP OES quanto para ICP-MS. As interferências causadas pela matriz de cinza de carvão e água do mar foram menores quando foi utilizado o nebulizador ultrassônico. A precisão e exatidão também foram melhores para a maioria dos elementos, quando utilizada a nebulização ultrassônica. Para ambas as técnicas, ICP OES e ICP-MS, os melhores limites de detecção (LDs) foram obtidos mediante os nebulizadores ultrassônico e pneumático com dessolvatação do aerossol. Em relação aos procedimentos de preparo da amostra avaliados para a cinza de carvão, sedimento de rio e sedimento do Tibet, melhores resultados foram obtidos quando se empregou mistura composta por HNO3, HF e H2O2 para decompor a amostra, com posterior adição de H3BO3. No entanto, para a amostra de fluorita a fusão alcalina foi mais eficiente. Já para a pilha NiMH (matriz composta por metais e carbono) a decomposição com água-régia mostrou-se mais eficiente. O procedimento de pré-concentração dos lantanídeos mediante extração no ponto nuvem, utilizando-se como agente complexante o 1-(2-tenoil)-3,3,3-trifluoracetona (2-TTA) e como surfactante o octilfenoxipolietoxietanol (Triton X-114) mostrou-se restrito para amostras de água doce. Isto porque há interferência da matriz na formação dos complexos dos lantanídeos na presença de constituintes de matrizes mais complexas. Também foi desenvolvida metodologia para separação da matriz/pré-concentração dos lantanídeos utilizando-se minicoluna empacotada com 8-HQ (8-hidroxiquinolina imobilizada em vidro de porosidade controlada), com o intuito de diminuir as interferências causadas pela matriz água do mar. Parâmetros tais como pH da amostra, concentração do eluente, vazão da amostra e vazão de eluente foram avaliados. Os limites de detecção obtidos variaram entre 0,42 a 0,09 ηg L-1, enquanto que o fator de enriquecimento variou de 2,06 a 3,68. O método mostrou-se eficiente, com boa precisão (desvio padrão relativo entre 2,5 a 10%) e exatidão (recuperação entre 88 a 98%). Para cada ciclo de pré-concentração foram utilizados 3 mL da amostra e o tempo de pré-concentração e determinação foi 8 minutos. O efeito de matriz e do solvente orgânico com respeito à determinação dos lantanídeos foi também investigado mediante análise de vinho. A amostra de vinho tinto foi preparada através de sonicação e digestão ácida. Os melhores resultados foram obtidos mediante sonicação com sonda por 90 s e a amostra diluída 10 vezes. Neste caso, a solução da amostra de vinho foi introduzida no plasma mediante sistema de injeção em fluxo (FI) acoplado ao nebulizador pneumático com sistema de dessolvatação. Mediante análise multivariada os vinhos puderam ser discriminados de acordo com os países de origem na América do Sul, independentemente do tipo da uva, com exceção dos vinhos chilenos. / This work deals with the development of methods for lanthanides determination by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) in different matrices: coal fly ash, river sediment, Tibet sediment, sea water, fluorite, nickel-metal hydride (NiMH) battery, fresh water and red wine. Three different nebulizers were investigated for sample introduction into the plasma (pneumatic nebulizer, ultrasonic nebulizer and pneumatic nebulizer/aerosol desolvation were compared). Two spectral lines per element were at least monitored for determinations using ICP OES. The nebulizer gas flow rate and plasma power were evaluated. Depending on the sample, additional spectral lines needed to be monitored due to matrix interference. The nebulizer gas flow rate and RF power applied varied according to the element measured and nebulizer used, for both ICP OES and ICP-MS techniques. Matrix interference caused by coal fly ash and sea water was lower when ultrasonic nebulization was used. The precision and accuracy were also better for most elements by using ultrasonic nebulization. For both ICP OES and ICP-MS techniques, better limits of detection (LODs) were obtained using ultrasonic nebulization and pneumatic nebulization/aerosol desolvation. In relation to the sample preparation procedures evaluated for coal fly ash, river sediment and Tibet sediment, better results were obtained when HNO3, HF and H2O2 were used followed by addition of H3BO3. However, fluorite was more efficiently decomposed by using alkaline fusion. On the other hand, aqua regia was more efficient for nickel-metal hydride (NiMH) batteries decomposition. Pre-concentration of lanthanides by cloud point extraction, using 1-(2-thenoyl)-3,3,3-trifluoraceton (2-TTA) as complexant and octylphenoxypolyethoxyethanol (Triton X-114) as surfactant, revealed to be feasible only for lanthanides in fresh water. Matrix interference was observed for others materials and samples. Matrix separation/pre-concentration of lanthanides using minicolumn packed with 8-HQ (8-hydroxyquinoline immobilized on controlled pore glass) was also investigated. Parameters such as pH, eluent concentration, sample and eluent flow rate were evaluated. The LODs obtained ranged from 0.42 to 0.09 ηg L-1, while the enrichment factor ranged from 2.06 to 3.68. The method proved to be efficient, with good precision (relative standard deviation between 2.5 and 10%) and accuracy (recovery between 88 to 98%). For each cycle of pre-concentration 3 mL of sample were used, while the time needed for pre-concentration and determination was 8 minutes. The effect of matrix and organic solvent with respect to lanthanides determination using ICP-MS was also investigated by analysis of red wine. Ultrasound and acid digestion were used for sample preparation. Best results were obtained by sonication with a probe for 90 s and sample 10-fold diluted. The wine sample solution was introduced into the plasma using flow injection (FI) and pneumatic nebulization/aerosol desolvation. By multivariate analysis the wines could be discriminated according to the country of origin in South America, regardless of the type of grape, with the exception of Chilean wines.
23

Desenvolvimento de métodos analíticos para a determinação de lantanídeos por técnicas de espectrometria atômica com plasma indutivamente acoplado

Bentlin, Fabrina Regia Stumm January 2012 (has links)
Neste trabalho foram desenvolvidos métodos analíticos para a determinação de lantanídeos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massa com fonte de plasma indutivamente acoplado (ICP-MS) em diferentes tipos de matrizes: cinza de carvão, sedimento de rio, sedimento do Tibet, fluorita, pilha recarregável do tipo NiMH, água do mar, água doce e vinho tinto. Três diferentes nebulizadores foram investigados para a introdução da amostra no plasma (os nebulizadores microconcêntrico, ultrassônico e pneumático com dessolvatação do aerossol foram comparados). Nas determinações por ICP OES foram monitoradas, pelo menos, duas linhas espectrais por elemento e avaliadas a vazão do gás de nebulização e potência de radiofrequência. Dependendo da matriz da amostra, linhas espectrais adicionais foram monitoradas, devido a interferências da matriz. A vazão do gás de nebulização e a potência de radiofrequência aplicada ao plasma foram variadas conforme o elemento medido e o nebulizador utilizado, tanto para ICP OES quanto para ICP-MS. As interferências causadas pela matriz de cinza de carvão e água do mar foram menores quando foi utilizado o nebulizador ultrassônico. A precisão e exatidão também foram melhores para a maioria dos elementos, quando utilizada a nebulização ultrassônica. Para ambas as técnicas, ICP OES e ICP-MS, os melhores limites de detecção (LDs) foram obtidos mediante os nebulizadores ultrassônico e pneumático com dessolvatação do aerossol. Em relação aos procedimentos de preparo da amostra avaliados para a cinza de carvão, sedimento de rio e sedimento do Tibet, melhores resultados foram obtidos quando se empregou mistura composta por HNO3, HF e H2O2 para decompor a amostra, com posterior adição de H3BO3. No entanto, para a amostra de fluorita a fusão alcalina foi mais eficiente. Já para a pilha NiMH (matriz composta por metais e carbono) a decomposição com água-régia mostrou-se mais eficiente. O procedimento de pré-concentração dos lantanídeos mediante extração no ponto nuvem, utilizando-se como agente complexante o 1-(2-tenoil)-3,3,3-trifluoracetona (2-TTA) e como surfactante o octilfenoxipolietoxietanol (Triton X-114) mostrou-se restrito para amostras de água doce. Isto porque há interferência da matriz na formação dos complexos dos lantanídeos na presença de constituintes de matrizes mais complexas. Também foi desenvolvida metodologia para separação da matriz/pré-concentração dos lantanídeos utilizando-se minicoluna empacotada com 8-HQ (8-hidroxiquinolina imobilizada em vidro de porosidade controlada), com o intuito de diminuir as interferências causadas pela matriz água do mar. Parâmetros tais como pH da amostra, concentração do eluente, vazão da amostra e vazão de eluente foram avaliados. Os limites de detecção obtidos variaram entre 0,42 a 0,09 ηg L-1, enquanto que o fator de enriquecimento variou de 2,06 a 3,68. O método mostrou-se eficiente, com boa precisão (desvio padrão relativo entre 2,5 a 10%) e exatidão (recuperação entre 88 a 98%). Para cada ciclo de pré-concentração foram utilizados 3 mL da amostra e o tempo de pré-concentração e determinação foi 8 minutos. O efeito de matriz e do solvente orgânico com respeito à determinação dos lantanídeos foi também investigado mediante análise de vinho. A amostra de vinho tinto foi preparada através de sonicação e digestão ácida. Os melhores resultados foram obtidos mediante sonicação com sonda por 90 s e a amostra diluída 10 vezes. Neste caso, a solução da amostra de vinho foi introduzida no plasma mediante sistema de injeção em fluxo (FI) acoplado ao nebulizador pneumático com sistema de dessolvatação. Mediante análise multivariada os vinhos puderam ser discriminados de acordo com os países de origem na América do Sul, independentemente do tipo da uva, com exceção dos vinhos chilenos. / This work deals with the development of methods for lanthanides determination by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) in different matrices: coal fly ash, river sediment, Tibet sediment, sea water, fluorite, nickel-metal hydride (NiMH) battery, fresh water and red wine. Three different nebulizers were investigated for sample introduction into the plasma (pneumatic nebulizer, ultrasonic nebulizer and pneumatic nebulizer/aerosol desolvation were compared). Two spectral lines per element were at least monitored for determinations using ICP OES. The nebulizer gas flow rate and plasma power were evaluated. Depending on the sample, additional spectral lines needed to be monitored due to matrix interference. The nebulizer gas flow rate and RF power applied varied according to the element measured and nebulizer used, for both ICP OES and ICP-MS techniques. Matrix interference caused by coal fly ash and sea water was lower when ultrasonic nebulization was used. The precision and accuracy were also better for most elements by using ultrasonic nebulization. For both ICP OES and ICP-MS techniques, better limits of detection (LODs) were obtained using ultrasonic nebulization and pneumatic nebulization/aerosol desolvation. In relation to the sample preparation procedures evaluated for coal fly ash, river sediment and Tibet sediment, better results were obtained when HNO3, HF and H2O2 were used followed by addition of H3BO3. However, fluorite was more efficiently decomposed by using alkaline fusion. On the other hand, aqua regia was more efficient for nickel-metal hydride (NiMH) batteries decomposition. Pre-concentration of lanthanides by cloud point extraction, using 1-(2-thenoyl)-3,3,3-trifluoraceton (2-TTA) as complexant and octylphenoxypolyethoxyethanol (Triton X-114) as surfactant, revealed to be feasible only for lanthanides in fresh water. Matrix interference was observed for others materials and samples. Matrix separation/pre-concentration of lanthanides using minicolumn packed with 8-HQ (8-hydroxyquinoline immobilized on controlled pore glass) was also investigated. Parameters such as pH, eluent concentration, sample and eluent flow rate were evaluated. The LODs obtained ranged from 0.42 to 0.09 ηg L-1, while the enrichment factor ranged from 2.06 to 3.68. The method proved to be efficient, with good precision (relative standard deviation between 2.5 and 10%) and accuracy (recovery between 88 to 98%). For each cycle of pre-concentration 3 mL of sample were used, while the time needed for pre-concentration and determination was 8 minutes. The effect of matrix and organic solvent with respect to lanthanides determination using ICP-MS was also investigated by analysis of red wine. Ultrasound and acid digestion were used for sample preparation. Best results were obtained by sonication with a probe for 90 s and sample 10-fold diluted. The wine sample solution was introduced into the plasma using flow injection (FI) and pneumatic nebulization/aerosol desolvation. By multivariate analysis the wines could be discriminated according to the country of origin in South America, regardless of the type of grape, with the exception of Chilean wines.
24

Efeitos da adição de N2 em ICP OES com configuração axial

Scheffler, Guilherme Luiz January 2014 (has links)
As vantagens e os efeitos da adição de uma pequena quantidade de nitrogênio (N2) ao canal central do plasma indutivamente acoplado de argônio (Ar-ICP), com vista de observação axial, na espectrometria de emissão óptica (OES) foram investigados neste trabalho. A quantidade de N2, a vazão do gás nebulizador, a potência de radiofrequência (RF) aplicada e a taxa de aspiração da amostra foram avaliadas e comparadas para dois sistemas de introdução da amostra no plasma: nebulização pneumática com desolvatação do aerossol e nebulização pneumática convencional. Foi observado que a adição de N2 não atua no processo de nebulização ou transporte do aerossol até a fonte de excitação (ICP), mas sim modifica transferências energéticas no plasma. A maior condutividade térmica do N2 em comparação ao Ar modifica as distribuições energéticas no ICP, como demonstrado pelos sinais de emissão das linhas de Ar e emissão do Na. A razão Mg(II)-280,270 nm/Mg(I)-285,213 nm foi utilizada como parâmetro de diagnóstico para a robustez do plasma. Adicionando-se 20 mL min-1 de N2 ao gás nebulizador, aumentou-se a robustez do mesmo consideravelmente e reduziu-se os efeitos de matriz causados por elementos facilmente ionizáveis (Na, K e Ca). Para 40 linhas espectrais avaliadas, foi observado que as linhas iônicas são, em geral, mais afetadas que as linhas atômicas. Os limites de detecção, a precisão, a sensibilidade e a linearidade das curvas de calibração obtidas usando-se o plasma de composição mista (N2-Ar-ICP) foram similares aos obtidos usando-se o plasma convencional de argônio (Ar-ICP). A análise de cinco materiais de referência diferentes revelou que a exatidão não é degradada pela adição de N2 ao Ar-ICP. Além disso, foi possível determinar as concentrações de diversos elementos em suspensão de arroz, introduzida diretamente no ICP. Sendo assim, o plasma de composição mista é uma fonte de excitação apropriada para análise de matrizes complexas em ICP OES. / In this study, the advantages and effects of adding small amounts of N2 into the central channel of the Ar-ICP for axially viewed inductively coupled plasma optical emission spectrometry (ICP OES) were investigated. The N2 flow rate, nebulizer gas flow rate, RF power and sample uptake rate were evaluated for two different sample introduction systems: a conventional pneumatic nebulizer (PN) and a pneumatic nebulizer with aerosol dessolvation (PN/DES). It was observed that N2 neither affected solution nebulization nor aerosol transport but modified the ICP characteristics as demonstrated by argon and sodium emission. The ratio Mg(II)-280.270 nm/Mg(I)-285.213 nm was used as a diagnostic tool for plasma robustness. By adding 20 mL min-1 of N2 to the nebulizer gas, the ICP robustness increased significanlty and matrix effects caused by easily ionized elements (Na, K and Ca) were mitigated. For 40 spectral lines evaluated, it was observed that the emission signals of ionic lines were in general more affected by N2 than those of atomic lines. Detection limits, precision, sensitivity and linearity of calibration curves obtained using the mixed-gas plasma (N2-Ar-ICP) were almost similar to those obtained using the standard Ar-ICP. The analysis of five different certified reference materials revealed that accuracy was not degraded by adding N2 to the Ar-ICP. In addition, toxic and essential elements were quantified in rice slurry, which was directly introduced in the mixed-gas ICP using PN. The results obtained suggest that the mixed-gas plasma is an appropriate excitation source for complex matrices analysis using ICP OES.
25

Desenvolvimento de métodos analíticos para a determinação de metais e metalóides em tinta

Bentlin, Fabrina Regia Stumm January 2007 (has links)
Neste trabalho são descritas metodologias para a determinação de elementos traço (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sb e Sn), minoritários e majoritários (Al, Ba, Ca, Cr, Cu, Mg, Pb, Sr, Ti e Zn) em tintas de diferentes tipos e cores; tinta para uso em serigrafia (de cor branca, preta, azul, vermelha, verde e amarela), acrílica (de cor roxa) para pintura de madeira, esmalte (de cor branca, verde e amarela) e para tatuagem (de cor preta, vermelha, verde e amarela). Os elementos traço foram determinados por ICPMS (espectrometria de massa com plasma indutivamente acoplado) e os majoritários e minoritários por ICP OES (espectrometria de emissão ótica com plasma indutivamente acoplado). As tintas foram decompostas mediante três diferentes métodos. (1) Em forno de microondas, sendo pesados cerca de 0,200 g de amostra em frasco de quartzo, adicionados 8 mL de HNO3 e a mistura adequadamente aquecida. (2) Decomposição segundo o método descrito na ASTM D335-85a, com algumas alterações (menos massa de amostra foi utilizada no presente trabalho). Foram pesados 0,200 g de tinta em copo Becker, adicionados 5 mL de HNO3 (1:1) e a mistura levada à secura em uma chapa de aquecimento, sem ferver.O resíduo foi queimado em forno mufla a 500 °C por 2 horas e a cinza resultante solubilizada com 10 mL de HNO3 (1:1), sob aquecimento brando em chapa aquecida, até a obtenção de um volume final de 5 mL. Método (3), semelhante ao (2), porém no método (3) foi utilizado cadinho de Pt, com uma temperatura de queima de 600 °C, sendo adicionados às cinzas 2 mL de HF e 4 mL de HNO3 e o volume da mistura reduzido a 3 mL. Em todos os métodos de decomposição utilizados a solução da amostra foi transferida para frasco de polipropileno graduado e o volume elevado a 50 mL com água. O método de decomposição de tinta em copo de quartzo fechado com aquecimento em forno de microondas pode ser uma alternativa ao método da ASTM, pois se obteve bons resultados para a maioria dos elementos majoritários pesquisados. A exceção foi o Ti, cujos resultados obtidos foram melhores mediante utilização de HF e aquecimento em cadinho de Pt, sendo obtidas concentrações muito mais altas e estatisticamente diferentes daquelas determinadas através dos outros métodos. Em relação aos elementos traço, as diferenças entre os resultados obtidos foram maiores, pois mediante os procedimentos em sistema aberto obtiveram-se, para alguns elementos (Mn, Ni e Pb), concentrações mais altas e estatisticamente diferentes. No entanto, o As foi perdido e não detectado quando as amostras foram decompostas emsistema aberto. Além disso, as concentrações de Sb e Sn determinadas mediante os três métodos de decomposição empregados foram significativamente diferentes. Nas tintas para tatuagem foram encontradas baixas concentrações dos elementos investigados, ou não detectadas. As exceções foram o Zn e o Cu nas tintas preta e verde respectivamente, em que foram determinadas concentrações relativamente altas (em torno de 0,45%).O limite de detecção (LD) do Cd foi 0,45 ng g-1, enquanto que os LDs do Co, Cr, Cu, Ni e Pb foram; 0,11; 0,03; 0,21; 0,03 e 0,06 μg g-1, respectivamente. As massas características foram 1,21; 10,9; 7,45; 10,7; 19,6 e 21,8 pg de Cd, Co, Cr, Cu, Ni e Pb, respectivamente. Para a validação da metodologia, os resultados da análise por DS-GF AAS foram comparados com os obtidos por GF AAS e ICP-MS, determinados na solução da amostra de tinta decomposta em forno de microondas. Concluiu-se que a DS-GF AAS é adequada para a determinação de elementos traço em tinta, pois, para a maioria das amostras, as concentrações de Cd, Co, Cr, Cu, Ni e Pb determinadas mediante essa técnica não foram significativamente diferentes daquelas determinadas por ICP-MS e GF AAS. / This work deals with methodologies for the determination of trace (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sb e Sn), minor and major elements (Al, Ba, Ca, Cr, Cu, Mg, Pb, Sr, Ti e Zn) in paints. Paints of different types and colors were analyzed: silkscreen paints (white, black, blue, red, green and yellow), acrylic purple paint for wood, enamel paint (white, green and yellow) and tattoo ink (black, red, green and yellow). Trace elements were determined by inductively coupled plasma mass spectrometry (ICP-MS), while major and minor elements were determined by inductively coupled plasma optical emission spectrometry (ICP OES). The paints samples were decomposed by means of three different methods. (1) In microwave oven using quartz vessel, where 0,200 g of sample and 8 mL of HNO3 were added and the mixture submitted to microwave irradiation. (2) Decomposition according to the ASTM D335-85a method (excepting the sample mass that was reduced in the present work). To 0,200 g of paint in glass vessel 5 mL of HNO3 (1+1) were added and the mixture heated to dryness in a hot plate, without the boiling of the mixture. The residue was burned in furnace at 500 °C for 2 hours and the attained ash was dissolved with 10 mL of HNO3 (1:1). Then, the attained solution was heated kindly and the volume reduced to 5 mL. Method (3) was carried out in a similar way as method (2), but in method (3) a Pt crucible was used, the ashing temperature elevated to 600 °C and 2 mL of HF and 4 mL of HNO3 were added to the attained ashes. Then, the mixture was heated and the volume reduced to 3 mL. In methods (1), (2) and (3) the solutions of the samples were transferred to graduated polypropylene vessel and the volume completed to 50 mL with water. The microwave oven-decomposition method using quartz vessel can be an alternative to the ASTM method, since good results were obtained for major and minor elements. However, better results were obtained for Ti by using HF and heating in Pt crucible, which concentrations found were higher and significantly different than those obtained using the other methods. Regarding to trace elements, more differences were found. By using open vessels higher and statistically different concentrations of some elements were found (Mn, Ni e Pb). However, As was completely lost and not detected by using open vessel. Additionally, the concentrations of Sb and Sn determined by the different methods were significantly different. Low concentrations, or bellow the limits of detection (LDs),were found in the tattoo inks, excepting Zn and Cu in the black and green ones, respectively. The concentrations of Zn and Cu in these paints were high (about 0.45%). It was also developed a method for the determination of Cd, Co, Cr, Cu, Ni and Pb by direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS). Parameters like pyrolysis and atomization temperatures, use of modifier and amount of sample mass introduced in the atomizer were evaluated. The modifiers employed were Pd for Cd, Cu and Pb, Mg(NO3)2 for Co and carbon powder for Ni. Calibration was carried out with aqueous solutions, while the linear correlation coefficients (R2) of the attained calibration curves were at least 0.998. However, the amount of sample introduced in the atomizer was limited to few mg. The LD of Cd was 0.45 ng g-1, whereas those of Co, Cr, Cu, Ni and Pb were 0.11, 0.03, 0.2, 0.03 and 0.06 μg g-1, respectively. The characteristic masses were 1.21, 10.9, 7.45, 10.7, 19.6 and 21.8 pg of Cd, Co, Cr, Cu, Ni and Pb, respectively. The concentrations measured by DS-GF AAS were compared to those found in the digested samples, which were measured by GF AAS and ICP-MS. It was concluded that the DS-GF AAS technique is suitable for the determination of trace elements in paints. The concentrations of Cd, Co, Cr, Cu, Ni and Pb measured in most samples by DS-GF AAS were not significantly different than those found by ICP-MS and GF AAS.
26

Desenvolvimento de métodos analíticos para a determinação de metais e metalóides em tinta

Bentlin, Fabrina Regia Stumm January 2007 (has links)
Neste trabalho são descritas metodologias para a determinação de elementos traço (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sb e Sn), minoritários e majoritários (Al, Ba, Ca, Cr, Cu, Mg, Pb, Sr, Ti e Zn) em tintas de diferentes tipos e cores; tinta para uso em serigrafia (de cor branca, preta, azul, vermelha, verde e amarela), acrílica (de cor roxa) para pintura de madeira, esmalte (de cor branca, verde e amarela) e para tatuagem (de cor preta, vermelha, verde e amarela). Os elementos traço foram determinados por ICPMS (espectrometria de massa com plasma indutivamente acoplado) e os majoritários e minoritários por ICP OES (espectrometria de emissão ótica com plasma indutivamente acoplado). As tintas foram decompostas mediante três diferentes métodos. (1) Em forno de microondas, sendo pesados cerca de 0,200 g de amostra em frasco de quartzo, adicionados 8 mL de HNO3 e a mistura adequadamente aquecida. (2) Decomposição segundo o método descrito na ASTM D335-85a, com algumas alterações (menos massa de amostra foi utilizada no presente trabalho). Foram pesados 0,200 g de tinta em copo Becker, adicionados 5 mL de HNO3 (1:1) e a mistura levada à secura em uma chapa de aquecimento, sem ferver.O resíduo foi queimado em forno mufla a 500 °C por 2 horas e a cinza resultante solubilizada com 10 mL de HNO3 (1:1), sob aquecimento brando em chapa aquecida, até a obtenção de um volume final de 5 mL. Método (3), semelhante ao (2), porém no método (3) foi utilizado cadinho de Pt, com uma temperatura de queima de 600 °C, sendo adicionados às cinzas 2 mL de HF e 4 mL de HNO3 e o volume da mistura reduzido a 3 mL. Em todos os métodos de decomposição utilizados a solução da amostra foi transferida para frasco de polipropileno graduado e o volume elevado a 50 mL com água. O método de decomposição de tinta em copo de quartzo fechado com aquecimento em forno de microondas pode ser uma alternativa ao método da ASTM, pois se obteve bons resultados para a maioria dos elementos majoritários pesquisados. A exceção foi o Ti, cujos resultados obtidos foram melhores mediante utilização de HF e aquecimento em cadinho de Pt, sendo obtidas concentrações muito mais altas e estatisticamente diferentes daquelas determinadas através dos outros métodos. Em relação aos elementos traço, as diferenças entre os resultados obtidos foram maiores, pois mediante os procedimentos em sistema aberto obtiveram-se, para alguns elementos (Mn, Ni e Pb), concentrações mais altas e estatisticamente diferentes. No entanto, o As foi perdido e não detectado quando as amostras foram decompostas emsistema aberto. Além disso, as concentrações de Sb e Sn determinadas mediante os três métodos de decomposição empregados foram significativamente diferentes. Nas tintas para tatuagem foram encontradas baixas concentrações dos elementos investigados, ou não detectadas. As exceções foram o Zn e o Cu nas tintas preta e verde respectivamente, em que foram determinadas concentrações relativamente altas (em torno de 0,45%).O limite de detecção (LD) do Cd foi 0,45 ng g-1, enquanto que os LDs do Co, Cr, Cu, Ni e Pb foram; 0,11; 0,03; 0,21; 0,03 e 0,06 μg g-1, respectivamente. As massas características foram 1,21; 10,9; 7,45; 10,7; 19,6 e 21,8 pg de Cd, Co, Cr, Cu, Ni e Pb, respectivamente. Para a validação da metodologia, os resultados da análise por DS-GF AAS foram comparados com os obtidos por GF AAS e ICP-MS, determinados na solução da amostra de tinta decomposta em forno de microondas. Concluiu-se que a DS-GF AAS é adequada para a determinação de elementos traço em tinta, pois, para a maioria das amostras, as concentrações de Cd, Co, Cr, Cu, Ni e Pb determinadas mediante essa técnica não foram significativamente diferentes daquelas determinadas por ICP-MS e GF AAS. / This work deals with methodologies for the determination of trace (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sb e Sn), minor and major elements (Al, Ba, Ca, Cr, Cu, Mg, Pb, Sr, Ti e Zn) in paints. Paints of different types and colors were analyzed: silkscreen paints (white, black, blue, red, green and yellow), acrylic purple paint for wood, enamel paint (white, green and yellow) and tattoo ink (black, red, green and yellow). Trace elements were determined by inductively coupled plasma mass spectrometry (ICP-MS), while major and minor elements were determined by inductively coupled plasma optical emission spectrometry (ICP OES). The paints samples were decomposed by means of three different methods. (1) In microwave oven using quartz vessel, where 0,200 g of sample and 8 mL of HNO3 were added and the mixture submitted to microwave irradiation. (2) Decomposition according to the ASTM D335-85a method (excepting the sample mass that was reduced in the present work). To 0,200 g of paint in glass vessel 5 mL of HNO3 (1+1) were added and the mixture heated to dryness in a hot plate, without the boiling of the mixture. The residue was burned in furnace at 500 °C for 2 hours and the attained ash was dissolved with 10 mL of HNO3 (1:1). Then, the attained solution was heated kindly and the volume reduced to 5 mL. Method (3) was carried out in a similar way as method (2), but in method (3) a Pt crucible was used, the ashing temperature elevated to 600 °C and 2 mL of HF and 4 mL of HNO3 were added to the attained ashes. Then, the mixture was heated and the volume reduced to 3 mL. In methods (1), (2) and (3) the solutions of the samples were transferred to graduated polypropylene vessel and the volume completed to 50 mL with water. The microwave oven-decomposition method using quartz vessel can be an alternative to the ASTM method, since good results were obtained for major and minor elements. However, better results were obtained for Ti by using HF and heating in Pt crucible, which concentrations found were higher and significantly different than those obtained using the other methods. Regarding to trace elements, more differences were found. By using open vessels higher and statistically different concentrations of some elements were found (Mn, Ni e Pb). However, As was completely lost and not detected by using open vessel. Additionally, the concentrations of Sb and Sn determined by the different methods were significantly different. Low concentrations, or bellow the limits of detection (LDs),were found in the tattoo inks, excepting Zn and Cu in the black and green ones, respectively. The concentrations of Zn and Cu in these paints were high (about 0.45%). It was also developed a method for the determination of Cd, Co, Cr, Cu, Ni and Pb by direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS). Parameters like pyrolysis and atomization temperatures, use of modifier and amount of sample mass introduced in the atomizer were evaluated. The modifiers employed were Pd for Cd, Cu and Pb, Mg(NO3)2 for Co and carbon powder for Ni. Calibration was carried out with aqueous solutions, while the linear correlation coefficients (R2) of the attained calibration curves were at least 0.998. However, the amount of sample introduced in the atomizer was limited to few mg. The LD of Cd was 0.45 ng g-1, whereas those of Co, Cr, Cu, Ni and Pb were 0.11, 0.03, 0.2, 0.03 and 0.06 μg g-1, respectively. The characteristic masses were 1.21, 10.9, 7.45, 10.7, 19.6 and 21.8 pg of Cd, Co, Cr, Cu, Ni and Pb, respectively. The concentrations measured by DS-GF AAS were compared to those found in the digested samples, which were measured by GF AAS and ICP-MS. It was concluded that the DS-GF AAS technique is suitable for the determination of trace elements in paints. The concentrations of Cd, Co, Cr, Cu, Ni and Pb measured in most samples by DS-GF AAS were not significantly different than those found by ICP-MS and GF AAS.
27

Desenvolvimento de métodos analíticos para a determinação de metais e metalóides em tinta

Bentlin, Fabrina Regia Stumm January 2007 (has links)
Neste trabalho são descritas metodologias para a determinação de elementos traço (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sb e Sn), minoritários e majoritários (Al, Ba, Ca, Cr, Cu, Mg, Pb, Sr, Ti e Zn) em tintas de diferentes tipos e cores; tinta para uso em serigrafia (de cor branca, preta, azul, vermelha, verde e amarela), acrílica (de cor roxa) para pintura de madeira, esmalte (de cor branca, verde e amarela) e para tatuagem (de cor preta, vermelha, verde e amarela). Os elementos traço foram determinados por ICPMS (espectrometria de massa com plasma indutivamente acoplado) e os majoritários e minoritários por ICP OES (espectrometria de emissão ótica com plasma indutivamente acoplado). As tintas foram decompostas mediante três diferentes métodos. (1) Em forno de microondas, sendo pesados cerca de 0,200 g de amostra em frasco de quartzo, adicionados 8 mL de HNO3 e a mistura adequadamente aquecida. (2) Decomposição segundo o método descrito na ASTM D335-85a, com algumas alterações (menos massa de amostra foi utilizada no presente trabalho). Foram pesados 0,200 g de tinta em copo Becker, adicionados 5 mL de HNO3 (1:1) e a mistura levada à secura em uma chapa de aquecimento, sem ferver.O resíduo foi queimado em forno mufla a 500 °C por 2 horas e a cinza resultante solubilizada com 10 mL de HNO3 (1:1), sob aquecimento brando em chapa aquecida, até a obtenção de um volume final de 5 mL. Método (3), semelhante ao (2), porém no método (3) foi utilizado cadinho de Pt, com uma temperatura de queima de 600 °C, sendo adicionados às cinzas 2 mL de HF e 4 mL de HNO3 e o volume da mistura reduzido a 3 mL. Em todos os métodos de decomposição utilizados a solução da amostra foi transferida para frasco de polipropileno graduado e o volume elevado a 50 mL com água. O método de decomposição de tinta em copo de quartzo fechado com aquecimento em forno de microondas pode ser uma alternativa ao método da ASTM, pois se obteve bons resultados para a maioria dos elementos majoritários pesquisados. A exceção foi o Ti, cujos resultados obtidos foram melhores mediante utilização de HF e aquecimento em cadinho de Pt, sendo obtidas concentrações muito mais altas e estatisticamente diferentes daquelas determinadas através dos outros métodos. Em relação aos elementos traço, as diferenças entre os resultados obtidos foram maiores, pois mediante os procedimentos em sistema aberto obtiveram-se, para alguns elementos (Mn, Ni e Pb), concentrações mais altas e estatisticamente diferentes. No entanto, o As foi perdido e não detectado quando as amostras foram decompostas emsistema aberto. Além disso, as concentrações de Sb e Sn determinadas mediante os três métodos de decomposição empregados foram significativamente diferentes. Nas tintas para tatuagem foram encontradas baixas concentrações dos elementos investigados, ou não detectadas. As exceções foram o Zn e o Cu nas tintas preta e verde respectivamente, em que foram determinadas concentrações relativamente altas (em torno de 0,45%).O limite de detecção (LD) do Cd foi 0,45 ng g-1, enquanto que os LDs do Co, Cr, Cu, Ni e Pb foram; 0,11; 0,03; 0,21; 0,03 e 0,06 μg g-1, respectivamente. As massas características foram 1,21; 10,9; 7,45; 10,7; 19,6 e 21,8 pg de Cd, Co, Cr, Cu, Ni e Pb, respectivamente. Para a validação da metodologia, os resultados da análise por DS-GF AAS foram comparados com os obtidos por GF AAS e ICP-MS, determinados na solução da amostra de tinta decomposta em forno de microondas. Concluiu-se que a DS-GF AAS é adequada para a determinação de elementos traço em tinta, pois, para a maioria das amostras, as concentrações de Cd, Co, Cr, Cu, Ni e Pb determinadas mediante essa técnica não foram significativamente diferentes daquelas determinadas por ICP-MS e GF AAS. / This work deals with methodologies for the determination of trace (As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sb e Sn), minor and major elements (Al, Ba, Ca, Cr, Cu, Mg, Pb, Sr, Ti e Zn) in paints. Paints of different types and colors were analyzed: silkscreen paints (white, black, blue, red, green and yellow), acrylic purple paint for wood, enamel paint (white, green and yellow) and tattoo ink (black, red, green and yellow). Trace elements were determined by inductively coupled plasma mass spectrometry (ICP-MS), while major and minor elements were determined by inductively coupled plasma optical emission spectrometry (ICP OES). The paints samples were decomposed by means of three different methods. (1) In microwave oven using quartz vessel, where 0,200 g of sample and 8 mL of HNO3 were added and the mixture submitted to microwave irradiation. (2) Decomposition according to the ASTM D335-85a method (excepting the sample mass that was reduced in the present work). To 0,200 g of paint in glass vessel 5 mL of HNO3 (1+1) were added and the mixture heated to dryness in a hot plate, without the boiling of the mixture. The residue was burned in furnace at 500 °C for 2 hours and the attained ash was dissolved with 10 mL of HNO3 (1:1). Then, the attained solution was heated kindly and the volume reduced to 5 mL. Method (3) was carried out in a similar way as method (2), but in method (3) a Pt crucible was used, the ashing temperature elevated to 600 °C and 2 mL of HF and 4 mL of HNO3 were added to the attained ashes. Then, the mixture was heated and the volume reduced to 3 mL. In methods (1), (2) and (3) the solutions of the samples were transferred to graduated polypropylene vessel and the volume completed to 50 mL with water. The microwave oven-decomposition method using quartz vessel can be an alternative to the ASTM method, since good results were obtained for major and minor elements. However, better results were obtained for Ti by using HF and heating in Pt crucible, which concentrations found were higher and significantly different than those obtained using the other methods. Regarding to trace elements, more differences were found. By using open vessels higher and statistically different concentrations of some elements were found (Mn, Ni e Pb). However, As was completely lost and not detected by using open vessel. Additionally, the concentrations of Sb and Sn determined by the different methods were significantly different. Low concentrations, or bellow the limits of detection (LDs),were found in the tattoo inks, excepting Zn and Cu in the black and green ones, respectively. The concentrations of Zn and Cu in these paints were high (about 0.45%). It was also developed a method for the determination of Cd, Co, Cr, Cu, Ni and Pb by direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS). Parameters like pyrolysis and atomization temperatures, use of modifier and amount of sample mass introduced in the atomizer were evaluated. The modifiers employed were Pd for Cd, Cu and Pb, Mg(NO3)2 for Co and carbon powder for Ni. Calibration was carried out with aqueous solutions, while the linear correlation coefficients (R2) of the attained calibration curves were at least 0.998. However, the amount of sample introduced in the atomizer was limited to few mg. The LD of Cd was 0.45 ng g-1, whereas those of Co, Cr, Cu, Ni and Pb were 0.11, 0.03, 0.2, 0.03 and 0.06 μg g-1, respectively. The characteristic masses were 1.21, 10.9, 7.45, 10.7, 19.6 and 21.8 pg of Cd, Co, Cr, Cu, Ni and Pb, respectively. The concentrations measured by DS-GF AAS were compared to those found in the digested samples, which were measured by GF AAS and ICP-MS. It was concluded that the DS-GF AAS technique is suitable for the determination of trace elements in paints. The concentrations of Cd, Co, Cr, Cu, Ni and Pb measured in most samples by DS-GF AAS were not significantly different than those found by ICP-MS and GF AAS.
28

Determinações de macros e micro-constituintes em soro de leite e de suas disponibilidades nutricionais por ICP OES

Mirla Janaina Augusta Cidade 11 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho foram desenvolvidos métodos para a quantificação de Co, Mo, Mn, Cu Fe, Zn, Mg, Na, Ca e K por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) em amostras de soro de leite integral e leite desnatado, obtidas por coagulação enzimática e por coagulação ácida. As condições instrumentais foram previamente estabelecidas pela avaliação da robustez do plasma. O método desenvolvido por digestão ácida em chapa de aquecimento foi utilizado como referência, cujos resultados mostraram Co, Mo, Mn, Cu e Fe abaixo dos seus LOQs, desvios padrão relativos (RSDs) abaixo de 10 % e recuperações entre 90 e 110 % para a maioria dos elementos. Os resultados obtidos através do método de introdução direta apresentaram recuperações entre 90 e 110 % para os elementos estudados e RSDs inferiores a 10 %. Porém, quando comparados com método de referência (teste F e t, 95 % de confiança), revelaram diferenças significativas entre as concentrações, sendo observadas também interferências de matriz. A fim de minimizar esses efeitos, foi feita a sonicação prévia das amostras. As concentrações obtidas com o uso do banho de ultrassom foram similares às obtidas pelo método de referência (teste F e t, com 95 % de confiança), mostrando que o método é simples, rápido e eficiente para a quantificação dos elementos estudados em amostras de soro de leite. O método utilizando o banho de ultrassom foi utilizado para quantificação dos elementos em diferentes amostras de soro de leite, apresentando RSDs abaixo de 10 % e recuperações entre 90 e 110 % e que as concentrações para o Mg, Na, Ca e K não apresentam diferenças significativas (ANOVA, 95 % de confiança) entre as diferentes amostras, independente da coagulação empregada no preparo do soro de leite e do tipo de leite utilizado. Estudos relacionados à disponibilidade dos elementos também foram conduzidos, revelando as frações disponíveis nas amostras de soro de leite na faixa de 4,2 a 5,5 % para o Mg, 3,0 a 7,4 % para o Na, 12,3 a 14,7 % para o Ca e 5,1 a 5,8 % para o K. Além disso, as frações disponíveis determinadas para o Ca e para o K em todas as amostras, independentemente das suas concentrações no soro de leite e do tipo de coagulação empregada no seu preparo, não mostraram diferenças significativas (ANOVA, 95 % de confiança). Através desse estudo, espera-se contribuir para o entendimento da composição inorgânica e desses elementos no soro de leite para o organismo humano. / Methods for quantification of the elements of Co, Mo, Mn, Cu, Fe, Zn, Mg, Na, Ca and K by inductively coupled plasma optical emission spectrometry (ICP OES) in whey samples were developed. Instrumental conditions were previously established by evaluation of plasma robustness. The method of acidic digestion using a hot plate was employed as a reference method, in which Co, Mo, Mn, Cu and Fe were not detected. The relative standard deviation, RSD, was lower than 10 % and the recoveries were between 90-110 % for the most elements. The results obtained by direct introduction have presented recoveries between 90-110% for the studied elements and the values of RSD were lower than 10 %. However, when compared with the reference method (test F and t at 95 % confidence level) showed significant differences between their concentrations and it was also observed matrix interferences. In order to minimize these effects, the samples were previously submitted to an ultrasound treatment. The concentration values obtained with this treatment were similar to the concentration values obtained by reference method (test F and t at 95 % confidence level), showing that the method is simple, fast and efficient for the quantification of the elements studied in samples of whey. The method using ultrasound was applied to quantify the elements in different samples of whey, featuring RSD lower than 10 % and recoveries between 90-110%. The results showed that the concentration of Mg, Na, Ca and K are independent of both, the kind of coagulation and the type of milk used in the preparation of whey (ANOVA, 95 % confidence level) for all the samples. The bioacessibility studies of minerals present in whey samples were also carried out and it was verified that the bioaccessibility fractions of whey were between 4.2-5.5 % for Mg, 3.0-7.4 % for Na, 12.3-14.7 % for Ca and 5.1-5.8 % for K. Ca and K did not show significant differences (ANOVA, 95 % confidence level) for all the samples independent of the kind of preparation or milk used. Through this study, it was expected to contribute to understanding the inorganic composition of these elements in whey for the human.
29

Dissolução química parcial \"on line\" de aço inoxidável seguida de determinação de Cr, Mn e Ni por espectrometria de emissão ótica com plasma indutivamente acoplado (ICP-OES) / Partial on-line chemical dissolution of stainless steel followed by determination of Cr, Mn and Ni by inductively coupled plasma optical emission spectrometry (ICP-OES)

Capri, Maria da Rosa 08 February 2001 (has links)
O objetivo deste trabalho foi o desenvolvimento de metodologia analítica versátil e rápida para a determinação de Cr, Mn e Ni em aços martensíticos e austeníticos, através do processo de dissolução química parcial em sistema de injeção em fluxo acoplado ao Espectrômetro de Emissão Ótica acoplado indutivamente (ICP-OES). O procedimento, também priorizou menor manipulação de amostra e consumo de reagentes. A solução extratora, HNO3 e HCI 7,0 mol L-1 e 6,0 mol L-1 respectivamente 1:1 v/v foi utilizada para a dissolução química parcial dos aços inoxidáveis. A quantificação dos metais dissolvidos foi feita utilizando-se o método da somatória, que relaciona a concentração de um elemento individual com a somatória dos elementos determinados, segundo a fórmula: i% = Ci /Ct x 100, onde Ci é a concentração do elemento i e Ct é a soma das concentrações de todos elementos determinados. Os resultados não apresentaram diferença significativa em um nível de confiança de 95% com os valores certificados das amostras de referência e com os valores da dissolução total assistida por microondas. O procedimento apresentou freqüência analítica de 20 determinações por hora. / The objective of this work was the development of a versatile and fast analytical methodology for the determination of Cr, Mn, and Ni in martensitic and austenitic steels, through on-line partial chemical dissolution using a flow injection system coupled to an ICP-OES. The procedure also aimed the smallest sample manipulation and reagents consumption. The extractor solution, 7.0 mol L-1 HNO3 and 6.0 mol L-1 HCI 1:1 v/v, was used to the on-line partial chemical dissolution of the stainless steels. The quantification of the dissolved metals was made using a method, that relate the concentration of an individual element with the sum of all elements concentrations, applying the formula: i% = Ci /Ct x 100, where Ci is the concentration of the element i and Ct is the sum of the concentration of all elements determined. No significant difference has been present by the results, at a confidence level of 95%, with the certified values of the reference materials and with the total dissolution values obtained by microwave - assisted sample pretreatment. The procedure presented analytic frequency of 20 determinations per hour.
30

Dissolução química parcial \"on line\" de aço inoxidável seguida de determinação de Cr, Mn e Ni por espectrometria de emissão ótica com plasma indutivamente acoplado (ICP-OES) / Partial on-line chemical dissolution of stainless steel followed by determination of Cr, Mn and Ni by inductively coupled plasma optical emission spectrometry (ICP-OES)

Maria da Rosa Capri 08 February 2001 (has links)
O objetivo deste trabalho foi o desenvolvimento de metodologia analítica versátil e rápida para a determinação de Cr, Mn e Ni em aços martensíticos e austeníticos, através do processo de dissolução química parcial em sistema de injeção em fluxo acoplado ao Espectrômetro de Emissão Ótica acoplado indutivamente (ICP-OES). O procedimento, também priorizou menor manipulação de amostra e consumo de reagentes. A solução extratora, HNO3 e HCI 7,0 mol L-1 e 6,0 mol L-1 respectivamente 1:1 v/v foi utilizada para a dissolução química parcial dos aços inoxidáveis. A quantificação dos metais dissolvidos foi feita utilizando-se o método da somatória, que relaciona a concentração de um elemento individual com a somatória dos elementos determinados, segundo a fórmula: i% = Ci /Ct x 100, onde Ci é a concentração do elemento i e Ct é a soma das concentrações de todos elementos determinados. Os resultados não apresentaram diferença significativa em um nível de confiança de 95% com os valores certificados das amostras de referência e com os valores da dissolução total assistida por microondas. O procedimento apresentou freqüência analítica de 20 determinações por hora. / The objective of this work was the development of a versatile and fast analytical methodology for the determination of Cr, Mn, and Ni in martensitic and austenitic steels, through on-line partial chemical dissolution using a flow injection system coupled to an ICP-OES. The procedure also aimed the smallest sample manipulation and reagents consumption. The extractor solution, 7.0 mol L-1 HNO3 and 6.0 mol L-1 HCI 1:1 v/v, was used to the on-line partial chemical dissolution of the stainless steels. The quantification of the dissolved metals was made using a method, that relate the concentration of an individual element with the sum of all elements concentrations, applying the formula: i% = Ci /Ct x 100, where Ci is the concentration of the element i and Ct is the sum of the concentration of all elements determined. No significant difference has been present by the results, at a confidence level of 95%, with the certified values of the reference materials and with the total dissolution values obtained by microwave - assisted sample pretreatment. The procedure presented analytic frequency of 20 determinations per hour.