• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 1
  • Tagged with
  • 20
  • 20
  • 20
  • 12
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Quantificação da resoluçao do sistema SPECT-CZT através do uso da função de transferência modulada (MTF) /

Zandona, Ednaldo Alexandre. January 2013 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: José Roberto Saglieti / Banca: Eder Rezende Moraes / Resumo: A medicina nuclear é uma especialidade médica que se ocupa de técnicas de imagem para observar o estado fisiológico dos tecidos ou órgãos de forma não invasiva, através da marcação de moléculas participantes desses processos, com isótopos radioativos, originando assim os chamados radionuclídeos. O SPECT é um equipamento que se utiliza de imagens planares, obtidas de vários ângulos ao redor do objeto de interesse, e, através de algoritmos computacionais, obtêm uma imagem tomográfica dessas projeções. Sua origem remete há aproximadamente cinquenta anos atrás, com criação da Câmara Anger (Hall Anger, 1964). Durante todo esse tempo, embora tenha havido alguma evolução, a estrutura dessas gama câmaras praticamente ficou Inalterada. Os constantes avanços em pesquisas empregando cristais semicondutores nos exames cintilográficos, bem como a necessidade do surgimento de novos sistemas detectores, compactos, com maior poder de resolução e alta sensibilidade conjugados a crescente preocupação mundial com a minimização das doses de radiação ionizante utilizadas nos exames diagnósticos e terapias, impulsionou o desenvolvimento de novos sistemas detectores. Recentemente, duas Grandes Empresas lançaram comercialmente novos sistemas de detecção para aquisições tomográficas em medicina nuclear, utilizando detectores do estado sólido, mais especificamente cristais de telureto de cádmio e zinco (CZT). Algumas vantagens desse tipo de detector são a melhora sensível da relação sinal/ruído, o aumento da resolução espectral e espacial, o que em suma, resultam numa maior nitidez das imagens obtidas. O emprego desses detectores abre novas perspectivas para os protocolos de imagem. Entretanto, devido a inúmeros fatores, os equipamentos ditos CZT estão focados na área cardiológica, e devido a características próprias requerem a reformulação dos protocolos de aquisição de imagem além daqueles destinados ao ... / Abstract: Nuclear medicine is a medical specialty that deals with imaging techniques to observe the physiological status of the tissues or organs noninvasively, by dialing molecules participating in this process, with radioactive isotopes, thus giving the so-called radionuclides. The SPECT is a device that uses planar images, taken from different angles around the object of interest, and, through computer algorithms, obtains a tomographic image of those projections. Its origin refers for nearly fifty years ago, with the creation of the Chamber Anger (Anger Hall, 1964). Throughout this time, although there has been some evolution, the structure of these gamma cameras was virtually unchanged. The constant advances in research employing semiconductor crystals in scintigraphic examinations, as well as the need for the creation of new detectors systems, compacts, higher resolution and high sensitivity; combined with growing worldwide concern with minimization of doses of ionizing radiation used in diagnostic tests and therapies, spurred the development of new detector systems. Recently, two large companies launched commercially new detection systems for nuclear medicine tomographic acquisitions, using solid-state detectors, specifically crystals of zinc and cadmium telluride (CZT). Some advantages of this type of detector are sensitive improvement of signal / noise ratio, increased spectral and spatial resolution, which in short, resulting in greater clarity of the images obtained. The use of these detectors opens news perspectives for imaging protocols. However, due to numerous factors, equipment said CZT are focused on cardiology area, and due to the inherent characteristics, require reformulation of image acquisition protocols beyond those intended for Quality Control / Mestre
12

Espectroscopia Mössbauer : condições experimentais de aquisição e estocagem multicanal para a análise numérica de dados com adequação de resolução espectral

Shigeyosi, Willian Takemitsu 15 February 2012 (has links)
Made available in DSpace on 2016-06-02T20:16:49Z (GMT). No. of bitstreams: 1 4390.pdf: 4535971 bytes, checksum: 8f50d48a2ff453c49779a243dbcaf285 (MD5) Previous issue date: 2012-02-15 / Financiadora de Estudos e Projetos / The objective of this work is to examine the use of Mossbauer spectroscopy in two aspects: the data acquisition, using four different setups and their analysis, comparing three different fittings programs. Concerning to acquisition, we showed that the adaptation of the Ortec MCS-32 system acquisition, to use not just 512 channels but as well 1024, 2048 and 4096 channels can improve the spectra quality. However, the time acquisition increases, proportionally to the increase of channels number. Four different samples were used in these tests, whose data were acquired using 512, 1024, 2048 and 4096 channels. The first and second samples analyzed, were two clay from Sta. Gertrudes region in São Paulo´s state -BR which had been treated in different conditions. Although the spectra resolution was better, in this case, we showed that the results quality are similar, independently of the channels number. The third one was pellet of iron ore, produced by Cia. Vale do Rio Doce . In this case, the use of 2048 channels data was suitable to identify a structure, not observed when less channels were used. It was propitiate as well by the fitting through the WinNormos for Igor. At last, we re-analyzed some spectra, acquired using 512 channels, from a previous study of our research group, on the AISI 316L stainless steel, applying the WinNormos for Igor. The spectra were fitted using the site plus field distribution model , conducting to better identification of the phases and their percent in the samples. The study and comparison of the three PC fitting programs showed that the WinNormos for Igor, is the most appropriate because its use is very simple, and permits much more flexibility on the fittings, making possible distribution on the different sensible parameters on the function used in the fitting. / Objetivo deste trabalho é examinar o uso da Espectroscopia Mössbauer em dois aspectos: aquisição de dados, usando quatro diferentes arranjos e a sua análise, comparando três diferentes programas de ajuste. Relativo à aquisição, mostramos que a adaptação do sistema de aquisição Ortec MCS-32, para usar não só 512 canais, mas também 1024, 2048 e 4096 canais pode melhorar a qualidade dos espectros. Entretanto, o tempo de aquisição aumenta, proporcionalmente ao aumento do número de canais. Quatro diferentes amostras foram usadas nestes testes, cujos dados foram obtidos usando 512, 1024, 2048 e 4096 canais. A primeira e a segunda amostra analisadas foram duas argilas de Sta. Gertrudes , uma região no estado de São Paulo-BR, as quais foram tratadas em diferentes condições. Embora a resolução dos espectros fiarem melhor, neste caso, mostramos que a qualidade dos resultados são similares, independente do número de canais. A terceira amostra foi pelotas de minério de ferro, produzidas pela Cia Vale do Rio Doce . Neste caso, o uso de 2048 canais proporcionou a identificação uma estrutura, não observada quando menor número de canais foi usado. Essa conclusão foi possível, também pelo ajuste com o programa WinNormos for Igor. Finalmente, nos re-analisamos alguns espectros, obtidos usando 512 canais, de um trabalho anterior produzido em nosso Grupo de pesquisa, no aço inoxidável AISI-316L, aplicando o WinNormos for Igor. Os espectros foram ajustados usando o modelo sítio mais distribuição de campo , o que nos levou a uma melhor identificação das fases e sua porcentagem na amostra. O estudo e comparação dos três programas de ajuste, mostrou que o WinNormos for Igor é o mais apropriado pois é simples e muito mais flexível no uso, possibilitando a distribuição nos diferentes parâmetros sensíveis da função usada no ajuste.
13

Quantificação da resoluçao do sistema SPECT-CZT através do uso da função de transferência modulada (MTF)

Zandona, Ednaldo Alexandre [UNESP] 22 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-22Bitstream added on 2014-06-13T20:10:26Z : No. of bitstreams: 1 000749206.pdf: 2362410 bytes, checksum: f4f84a869a32983e7c75a2cda7ba0e17 (MD5) / A medicina nuclear é uma especialidade médica que se ocupa de técnicas de imagem para observar o estado fisiológico dos tecidos ou órgãos de forma não invasiva, através da marcação de moléculas participantes desses processos, com isótopos radioativos, originando assim os chamados radionuclídeos. O SPECT é um equipamento que se utiliza de imagens planares, obtidas de vários ângulos ao redor do objeto de interesse, e, através de algoritmos computacionais, obtêm uma imagem tomográfica dessas projeções. Sua origem remete há aproximadamente cinquenta anos atrás, com criação da Câmara Anger (Hall Anger, 1964). Durante todo esse tempo, embora tenha havido alguma evolução, a estrutura dessas gama câmaras praticamente ficou Inalterada. Os constantes avanços em pesquisas empregando cristais semicondutores nos exames cintilográficos, bem como a necessidade do surgimento de novos sistemas detectores, compactos, com maior poder de resolução e alta sensibilidade conjugados a crescente preocupação mundial com a minimização das doses de radiação ionizante utilizadas nos exames diagnósticos e terapias, impulsionou o desenvolvimento de novos sistemas detectores. Recentemente, duas Grandes Empresas lançaram comercialmente novos sistemas de detecção para aquisições tomográficas em medicina nuclear, utilizando detectores do estado sólido, mais especificamente cristais de telureto de cádmio e zinco (CZT). Algumas vantagens desse tipo de detector são a melhora sensível da relação sinal/ruído, o aumento da resolução espectral e espacial, o que em suma, resultam numa maior nitidez das imagens obtidas. O emprego desses detectores abre novas perspectivas para os protocolos de imagem. Entretanto, devido a inúmeros fatores, os equipamentos ditos CZT estão focados na área cardiológica, e devido a características próprias requerem a reformulação dos protocolos de aquisição de imagem além daqueles destinados ao... / Nuclear medicine is a medical specialty that deals with imaging techniques to observe the physiological status of the tissues or organs noninvasively, by dialing molecules participating in this process, with radioactive isotopes, thus giving the so-called radionuclides. The SPECT is a device that uses planar images, taken from different angles around the object of interest, and, through computer algorithms, obtains a tomographic image of those projections. Its origin refers for nearly fifty years ago, with the creation of the Chamber Anger (Anger Hall, 1964). Throughout this time, although there has been some evolution, the structure of these gamma cameras was virtually unchanged. The constant advances in research employing semiconductor crystals in scintigraphic examinations, as well as the need for the creation of new detectors systems, compacts, higher resolution and high sensitivity; combined with growing worldwide concern with minimization of doses of ionizing radiation used in diagnostic tests and therapies, spurred the development of new detector systems. Recently, two large companies launched commercially new detection systems for nuclear medicine tomographic acquisitions, using solid-state detectors, specifically crystals of zinc and cadmium telluride (CZT). Some advantages of this type of detector are sensitive improvement of signal / noise ratio, increased spectral and spatial resolution, which in short, resulting in greater clarity of the images obtained. The use of these detectors opens news perspectives for imaging protocols. However, due to numerous factors, equipment said CZT are focused on cardiology area, and due to the inherent characteristics, require reformulation of image acquisition protocols beyond those intended for Quality Control
14

Detecção de rodovias em imagens digitais de alta resolução com o uso da teoria de morfologia matemática /

Ishikawa, Aline Sayuri. January 2008 (has links)
Orientador: Erivaldo Antonio da Silva / Banca: José Roberto Nogueira / Banca: Rodrigo Affonso de Albuquerque Nóbrega / Resumo: O presente trabalho busca desenvolver um método de detecção de rodovias em imagens digitais de alta resolução baseado na teoria de Morfologia Matemática (MM). O uso da MM tem como principal justificativa a utilização de operadores morfológicos como método alternativo para detecção de rodovias visando contribuir para a área de Cartografia, visto que esta é uma excelente ferramenta não-linear que resolve de forma eficiente problemas de extração de informação através da análise das estruturas geométricas dos alvos contidos nas imagens digitais. A área de estudo corresponde a uma imagem pancromática contendo um trecho da Rodovia Raposo Tavares, localizado na região de Presidente Prudente (SP), sendo adquirida pelo satélite de alta resolução Quickbird com resolução espacial de 0,60 m. Para a detecção das pistas de rodovia, desenvolveu-se uma rotina baseada em operadores morfológicos e elementos estruturantes contidos na SDC Morphology Toolbox, a qual roda em ambiente MATLAB. Devido à baixa eficiência do MATLAB em processar imagens com grande dimensão foi necessário recortar a área teste em 11 sub-imagens. Desse modo, a rotina morfológica teve que ser capaz de detectar feições do tipo rodovia nas 11 sub-imagens, alterando-se apenas os valores dos limiares, os quais diferem para cada imagem. Para a elaboração da rotina, inicialmente, com base no tipo de alvo presente na imagem (i.e., rodovias), foram selecionados os operadores e elementos estruturantes morfológicos mais adequados para serem utilizados no processo de detecção. / Abstract: The present work intends to develop a road detection method in high resolution digital imagery based on the Mathematical Morphology theory (MM). The choice of MM has as a main reason the use of morphologic operators as an alternative method for road detection seeking to contribute for the Cartography area, because this is an excellent nonlinear tool that efficiently solves problems of information extraction through the analysis of geometric structures in the target contained in the digital images. The study area corresponds to a panchromatic image containing a passage of the Raposo Tavares Road, located in Presidente Prudente (SP), being acquired by the high resolution satellite Quickbird with 0,60 m spatial resolution. For the road tracks detection it was developed a routine based in morphologic operators and structuring elements contained in SDC Morphology Toolbox, which turns in software Matlab. Due to the deficiency of Matlab in processing images with great dimension it was necessary to cut out the area tests in 11 sub-images. This way, the morphologic routine had to be able to detect features of the type road in the 11 sub-images, just losing temper the thresholds values, which differ for each image. For the routine elaboration, initially, basing in the type of present target in the image (i.e., roads), the most appropriated morphologic operators and structuring elements were selected to use in the detection process. / Mestre
15

Caracterização de zeolitas utilizando espectroscopia de alta resolução em sólidos por ressonância magnética nuclear / Characterization of zeolites using high-resolution solid-state nuclear magnetic resonance spectroscopy

Mello, Nilson Camargo 20 April 1993 (has links)
O objetivo deste trabalho consistiu na caracterização das zeólitas Y e ZSM-5, usando a técnica de Espectroscopia de Alta resolução em sólidos por Ressonância Magnética Nuclear (RMN). Os espectros de alta resolução do 13C e 27Al foram obtidos usando, simultaneamente, as técnicas de desacoplamento em alta potência (DEC) e rotação da amostra em torno de ângulo mágico (MAS). Utilizamos os espectros de alta resolução dos núcleos de 27Al para analisarmos a coordenação e a quantificação dos alumínios estruturais e extra-estruturais em zeólitas Y e de 13C para analisarmos o posicionamento de moléculas direcionadas localizadas nos canais da ZSM-5 / The objective of this work consisted of the characterization of zeolites Y and ZSM-5, using Solid State High Resolution Nuclear Magnetic Resonance Spectrsocopy. The 13C and 27Al high resolution spectra were obtained using simultaneously, High Power Decoupling (DEC) and Magic Angle Spinning (MAS). The high resolution 27Al spectra were used to distinguish and quantify framework and non-framework aluminium in zeolites Y. The high resolution 13C spectra were used to probe the position and configuration of the guest organic molecules within the framework of the ZSM-5 zeolite
16

Caracterização de zeolitas utilizando espectroscopia de alta resolução em sólidos por ressonância magnética nuclear / Characterization of zeolites using high-resolution solid-state nuclear magnetic resonance spectroscopy

Nilson Camargo Mello 20 April 1993 (has links)
O objetivo deste trabalho consistiu na caracterização das zeólitas Y e ZSM-5, usando a técnica de Espectroscopia de Alta resolução em sólidos por Ressonância Magnética Nuclear (RMN). Os espectros de alta resolução do 13C e 27Al foram obtidos usando, simultaneamente, as técnicas de desacoplamento em alta potência (DEC) e rotação da amostra em torno de ângulo mágico (MAS). Utilizamos os espectros de alta resolução dos núcleos de 27Al para analisarmos a coordenação e a quantificação dos alumínios estruturais e extra-estruturais em zeólitas Y e de 13C para analisarmos o posicionamento de moléculas direcionadas localizadas nos canais da ZSM-5 / The objective of this work consisted of the characterization of zeolites Y and ZSM-5, using Solid State High Resolution Nuclear Magnetic Resonance Spectrsocopy. The 13C and 27Al high resolution spectra were obtained using simultaneously, High Power Decoupling (DEC) and Magic Angle Spinning (MAS). The high resolution 27Al spectra were used to distinguish and quantify framework and non-framework aluminium in zeolites Y. The high resolution 13C spectra were used to probe the position and configuration of the guest organic molecules within the framework of the ZSM-5 zeolite
17

A espectroscopia de alta resolução em sólidos por RMN aplicada ao estudo de compostos híbridos sílica-polipropilenoglicol-LiClO4 condutores iônicos e do polímero condutor eletrônico poliparafenileno dopado com FeCl3 / Solid-state NMR high-resolution spectroscopy and relaxation applied to the study of hybrid ion conducting compounds silica/polypropylene-LiClO4 and electronic conducting polymer poly(para-phenylene) doped with FeCl3

Souza, Paulo Henrique de 27 February 1998 (has links)
Neste trabalho estudamos duas classes diferentes de materiais condutores através de várias técnicas: o polímero condutor eletrônico Poliparafenileno (PPP) dopado com FeCl3, e os compostos condutores iônicos orgânico-inorgânico complexados com LiClO4, chamados ormolitas. Um estudo comparativo de PPP dopado com FeCl3, por RMN de Alta Resolução em Sólidos de 13C , Ressonância Paramagnética Eletrônica, Susceptibilidade Magnética e Condutividade Elétrica foi realizado em função da concentração de Fe e da temperatura. Observou-se uma forte influência do íon paramagnético Fe3+ na largura de linha e nos tempos de relaxação spin-rede medidos por RMN de alta resolução através do 13C. OS resultados obtidos pelos diferentes métodos estão correlacionados e podem ser explicados pelo modelo polaron-bipolaron. Duas famílias de ormolitas, foram preparadas pelo processo sol-gel. Um estudo comparativo destes compostos por RMN de alta resolução multinuclear, Calorimetria Diferencial (DSC) e Condutividade Elétrica foi feito em função da concentração de lítio, do comprimento da cadeia polimérica, da razão polímero-sílica e da temperatura. Através das medidas de largura de linha dos espectros de RMN em função da temperatura, para os núcleos de 7Li e 13C, podemos observar uma forte correlação entre RMN, DSC e Condutividade Elétrica. Estes resultados confirmam que a condutividade iônica do lítio é governada pela mobilidade dos segmentos da cadeia polimérica, sendo esta responsável pela modulação das barreiras eletrostáticas nos sítios do íon Li+ / In this work we investigated two different classes of conducting materials using several techniques: the electronic conducting polymer FeC13-doped Polyparaphenylene (PPP) and the ionic conducting LiC1O4-complexed organic-inorganic nanocomposites called ormolytes. A comparative study of the FeC13, doped polyparaphenylene (PPP) by the 13C High-Resolution Solid-State NMR, Electron Paramagnetic Resonance (ESR), Magnetic Susceptibility, and electrical conductivity was made as a function of the iron concentration and the temperature. It is observed that a clear correlation among the results obtained from different methods takes place as a function of iron doping and temperature. which can be explained by polaron-bipolaron model and the presence of the paramagnetic ion Fe3+. Two families of hybrid organic-inorganic composites exhibiting ionic conduction properties, so called ORMOLYTES, have been prepared by the sol-gel process. A comparative study of these composites by the multinuclear High-Resolution Solid-State NMR, Differential Scanning Calorimetry (DSC), and electrical conductivity was made as a function of the lithium concentration, polymer chain length, polymer to silica ratio and the temperature. It was observe a strong correlation between NMR, DSC and electrical conductivity and this result corroborate the fact that the Li+ ionic conductivity is governed by the polymer chain mobility
18

A espectroscopia de alta resolução em sólidos por RMN aplicada ao estudo de compostos híbridos sílica-polipropilenoglicol-LiClO4 condutores iônicos e do polímero condutor eletrônico poliparafenileno dopado com FeCl3 / Solid-state NMR high-resolution spectroscopy and relaxation applied to the study of hybrid ion conducting compounds silica/polypropylene-LiClO4 and electronic conducting polymer poly(para-phenylene) doped with FeCl3

Paulo Henrique de Souza 27 February 1998 (has links)
Neste trabalho estudamos duas classes diferentes de materiais condutores através de várias técnicas: o polímero condutor eletrônico Poliparafenileno (PPP) dopado com FeCl3, e os compostos condutores iônicos orgânico-inorgânico complexados com LiClO4, chamados ormolitas. Um estudo comparativo de PPP dopado com FeCl3, por RMN de Alta Resolução em Sólidos de 13C , Ressonância Paramagnética Eletrônica, Susceptibilidade Magnética e Condutividade Elétrica foi realizado em função da concentração de Fe e da temperatura. Observou-se uma forte influência do íon paramagnético Fe3+ na largura de linha e nos tempos de relaxação spin-rede medidos por RMN de alta resolução através do 13C. OS resultados obtidos pelos diferentes métodos estão correlacionados e podem ser explicados pelo modelo polaron-bipolaron. Duas famílias de ormolitas, foram preparadas pelo processo sol-gel. Um estudo comparativo destes compostos por RMN de alta resolução multinuclear, Calorimetria Diferencial (DSC) e Condutividade Elétrica foi feito em função da concentração de lítio, do comprimento da cadeia polimérica, da razão polímero-sílica e da temperatura. Através das medidas de largura de linha dos espectros de RMN em função da temperatura, para os núcleos de 7Li e 13C, podemos observar uma forte correlação entre RMN, DSC e Condutividade Elétrica. Estes resultados confirmam que a condutividade iônica do lítio é governada pela mobilidade dos segmentos da cadeia polimérica, sendo esta responsável pela modulação das barreiras eletrostáticas nos sítios do íon Li+ / In this work we investigated two different classes of conducting materials using several techniques: the electronic conducting polymer FeC13-doped Polyparaphenylene (PPP) and the ionic conducting LiC1O4-complexed organic-inorganic nanocomposites called ormolytes. A comparative study of the FeC13, doped polyparaphenylene (PPP) by the 13C High-Resolution Solid-State NMR, Electron Paramagnetic Resonance (ESR), Magnetic Susceptibility, and electrical conductivity was made as a function of the iron concentration and the temperature. It is observed that a clear correlation among the results obtained from different methods takes place as a function of iron doping and temperature. which can be explained by polaron-bipolaron model and the presence of the paramagnetic ion Fe3+. Two families of hybrid organic-inorganic composites exhibiting ionic conduction properties, so called ORMOLYTES, have been prepared by the sol-gel process. A comparative study of these composites by the multinuclear High-Resolution Solid-State NMR, Differential Scanning Calorimetry (DSC), and electrical conductivity was made as a function of the lithium concentration, polymer chain length, polymer to silica ratio and the temperature. It was observe a strong correlation between NMR, DSC and electrical conductivity and this result corroborate the fact that the Li+ ionic conductivity is governed by the polymer chain mobility
19

Estudo de compostos LiMePO4 (Me=Mg, Co, Ni) através de Ressonância Magnética Nuclear / Studies of LiMePO4 (Me = Mg, Co, Ni) compounds through Nuclear Magnetic Resonance

Silva, Marcos Antonio da 06 October 2000 (has links)
Nesta dissertação é apresentado um estudo dos compostos Li1-3xMgFexPO4 através de Ressonância Magnética Nuclear (7Li e 31P), no intervalo de temperatura de 150 a 410 K. Estudos desses compostos através de técnicas de difração de elétrons e efeito Mossbauer confirmam que os íons Fe entram na rede cristalina na forma Fe3+, substituindo os íons Li+. O comportamento dos espectros de RMN, dos tempos de relaxação spin-rede e da susceptibilidade magnética dos núcleos 7Li e 31P em função da temperatura, em conjunto com medidas de condutividade iônica, indicam que, mesmo com a adição de impurezas Fe3+ na rede, os íons Li+ pouca mobilidade dentro do intervalo de temperatura utilizado. / This work reports a 7Li and 31P nuclear magnetic resonance study in the Li1-3xMgFexPO4 phases between 150 and 410 K. This study, complementary to those made using Mössbauer and magnetic neutron diffraction experiments, confirms that the Fe3+ ions enter as in the lattice, and that they enter substituting Li ions. The behavior of the 7Li e 31P nuclear magnetic resonance spectra, together with ionic conductivity measurements, show that no Li mobility occurs in temperature range studied even with the addition of the Fe impurity.
20

Estudo de compostos LiMePO4 (Me=Mg, Co, Ni) através de Ressonância Magnética Nuclear / Studies of LiMePO4 (Me = Mg, Co, Ni) compounds through Nuclear Magnetic Resonance

Marcos Antonio da Silva 06 October 2000 (has links)
Nesta dissertação é apresentado um estudo dos compostos Li1-3xMgFexPO4 através de Ressonância Magnética Nuclear (7Li e 31P), no intervalo de temperatura de 150 a 410 K. Estudos desses compostos através de técnicas de difração de elétrons e efeito Mossbauer confirmam que os íons Fe entram na rede cristalina na forma Fe3+, substituindo os íons Li+. O comportamento dos espectros de RMN, dos tempos de relaxação spin-rede e da susceptibilidade magnética dos núcleos 7Li e 31P em função da temperatura, em conjunto com medidas de condutividade iônica, indicam que, mesmo com a adição de impurezas Fe3+ na rede, os íons Li+ pouca mobilidade dentro do intervalo de temperatura utilizado. / This work reports a 7Li and 31P nuclear magnetic resonance study in the Li1-3xMgFexPO4 phases between 150 and 410 K. This study, complementary to those made using Mössbauer and magnetic neutron diffraction experiments, confirms that the Fe3+ ions enter as in the lattice, and that they enter substituting Li ions. The behavior of the 7Li e 31P nuclear magnetic resonance spectra, together with ionic conductivity measurements, show that no Li mobility occurs in temperature range studied even with the addition of the Fe impurity.

Page generated in 0.0398 seconds