• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 104
  • 2
  • Tagged with
  • 106
  • 106
  • 62
  • 46
  • 46
  • 38
  • 33
  • 32
  • 30
  • 28
  • 26
  • 20
  • 18
  • 16
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise do custo do ciclo de vida da ETA de Queimadela

Pereira, Arlindo Jorge Caetano January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Hidráulica, Recursos Hídricos e Ambiente). Faculdade de Engenharia. Universidade do Porto. 2009
12

Reciclagem do lodo de estação de tratamento de água : produção de coagulante por lixiviação ácida

Dandolini, Ivana January 2014 (has links)
A conversão do lodo em coagulante é uma das práticas considerada adequada para minimizar o impacto ambiental de destinação do lodo. A solubilização dos coagulantes e sua reciclagem permitem minimizar os custos e os problemas associados à disposição final dos lodos gerados em ETAs. Os processos de recuperação dos coagulantes podem ser realizados por via ácida, via alcalina e via extração com solventes orgânicos por complexação/quelação. Entretanto, a recuperação por via ácida (Processo Fulton) é a que tem se demonstrado a mais viável, tanto técnica como economicamente. Assim, o objetivo desse trabalho foi avaliar a possibilidade de recuperação de coagulante a partir do lodo de uma estação de tratamento de água. Optou-se pelo processo de recuperação por via ácida, utilizando-se ácido sulfúrico. A metodologia do trabalho envolveu: (a) a caracterização do lodo da ETA; (b) ensaios práticos de acidificação para recuperação de um coagulante misto à base de ferro e alumínio (considerando-se o uso de lodo “in natura” na forma pastoso/líquida, lodo seco a 105ºC e lodo calcinado a 500ºC; (c) análises dos coagulantes obtidos; (d) caracterização do lodo residual de acordo com NBR 10.004 (2004); e (e) realização de testes de tratamento de água com o coagulante obtido à partir do lodo de forma comparativa com o coagulante em uso atualmente na ETA. Os resultados demonstram que a recuperação do coagulante somente foi efetiva após a calcinação do lodo da ETA, para a eliminação da matéria orgânica presente. A aplicação do coagulante reciclado no tratamento de água foi igualmente eficiente ao coagulante tradicionalmente empregado, ambos atendendo a qualidade da água exigida na Portaria 2914/2011. / The conversion of coagulant sludge is one of the practices considered adequate to minimize the environmental impact of disposal of sludge. The solubilization of coagulants and enable their recycling to minimize the costs and problems associated with the disposal of sludge generated in ETAs. The coagulant recovery process may be performed by acid- route, and route via alkaline extraction by organic complexing / chelating solvents. However, the recovery by acid pathway (Case Fulton) is the one that has shown the most feasible , both technically and economically . The objective of this study was to evaluate the recoverability of coagulant sludge from a water treatment plant. We chose the recovery process by acid pathway, using sulfuric acid. The methodology of work involved : ( a) the characterization of sludge by ETA; ( b ) practical tests acidification recovery of a mixed coagulant based on iron and aluminum (considering the use of sludge " in natura " in paste / liquid form , dried sludge at 105 º C and calcined sludge at 500 º C ); ( c ) analyzes of coagulants obtained; ( d ) characterization of residual sludge according to NBR 10004 (2004 ); and (e ) conducting tests with water treatment coagulant obtained from the sludge in comparison with the coagulant in use today in the ETA . The results demonstrate that recovery of coagulant was only effective after calcination of the sludge ETA for the removal of organic matter. The application of recycled coagulant in water treatment was also effective in traditional coagulant employee, serving both the water quality required in Ordinance 2914/2011.
13

Avaliação técnica e operacional da estação de tratamento de esgotos por lodos ativados do campus do Pici da Universidade Federal do Ceará / Evaluation technical and operational of the activated sludge wastewater treatment plant of the "campus do Pici" of the Federal University of Ceará

Peixoto, Marcelo Silva 29 August 2008 (has links)
PEIXOTO, M. S. Avaliação técnica e operacional da estação de tratamento de esgotos por lodos ativados do campus do Pici da Universidade Federal do Ceará. 2008. 99 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-04-27T19:12:01Z No. of bitstreams: 1 2008_dis_mspeixoto.pdf: 1738762 bytes, checksum: 11ef73a5aa8f95d90c2ff6adf56177a9 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-06-02T18:02:15Z (GMT) No. of bitstreams: 1 2008_dis_mspeixoto.pdf: 1738762 bytes, checksum: 11ef73a5aa8f95d90c2ff6adf56177a9 (MD5) / Made available in DSpace on 2016-06-02T18:02:15Z (GMT). No. of bitstreams: 1 2008_dis_mspeixoto.pdf: 1738762 bytes, checksum: 11ef73a5aa8f95d90c2ff6adf56177a9 (MD5) Previous issue date: 2008-08-29 / Wastewater treatment is very important to maintain the quality of water bodies. The present work evaluated the technical and operational aspects of an activated sludge Wastewater Treatment Plant (WTP), classified as prolonged aeration, located at the “Campus do Pici” of the Federal University of Ceará, and propose some interventions to make compatible real and design efficiencies. The physical-chemical and biological water analysis of influent and effluent allowed to monitor the real WTP efficiency. Some operational parameters were assessed in the preliminary treatment, aeration tank and secondary settler. After the monitoring time, the real organic matter, nutrients and pathogens removal efficiencies were compared to values reported in literature for the activated sludge system in extended aeration, as well as for the operational parameters. Additionally, it was verified which parameters were below the limits reported in the regulation (Portaria no 154 of Secretaria de Meio ambiente do Ceará, Semace). It was concluded that the WTP was hydraulically overloaded, which is compromising the organic matter and pathogens removal, beside the low nutrients efficiency. Because of this, the WTP effluent is not accomplishing the regulation limits for ammonium and phosphorous. As a major intervention, we suggest the construction of other modules to distribute the inflow, with the aim of decrease the hydraulic overload problem, beside the possibility of including a tertiary treatment to decrease the nutrients concentrations. Only after these improvements we can think of ways to optimize the WTP to achieve the design efficiencies and effluent limits. / O tratamento de esgoto é fundamental para a manutenção da qualidade dos corpos d’água. O presente trabalho investigou os aspectos técnicos e operacionais da estação de tratamento de esgoto (ETE) por lodos ativados com aeração prolongada do Campus do Pici, situada na Universidade Federal do Ceará e propôs medidas corretivas para compatibilizar as eficiências reais com as de projeto. Por meio da análise dos parâmetros físicos, químicos e biológicos de qualidade de água no afluente e efluente avaliou-se a eficiência real da ETE, sendo que os principais parâmetros operacionais foram avaliados no tratamento preliminar, tanque de aeração e decantador secundário. De posse dos dados coletados, compararam-se os dados de eficiência com os valores citados na literatura para a tecnologia de lodos ativados por aeração prolongada, assim como os valores obtidos na avaliação operacional da ETE. Adicionalmente, foram verificados quais parâmetros atendiam aos limites da Portaria no 154 da Superintendência Estadual de Meio ambiente do Ceará (Semace). Constatou-se que a ETE está submetida à sobrecarga hidráulica, comprometendo desta forma a eficiência de remoção de matéria orgânica e patogênicos, além da baixa remoção de nutrientes, que faz com que o efluente não atenda aos limites da supracitada portaria para amônia e fósforo. Como principal intervenção na ETE, recomendou-se a construção de módulos complementares para distribuição da vazão afluente de forma a sanar o problema de sobrecarga hidráulica, além da possibilidade de inclusão de tratamento em nível terciário para o problema dos nutrientes. Só após a realização desta intervenção, poderão ser propostas medidas para a otimização da ETE e adequação do efluente a todos os padrões de lançamento estabelecidos e avaliados na presente investigação.
14

Asfaltos e misturas modificadas com materiais alternativos

Bastidas Martinez, Juan Gabriel 22 November 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-03-29T16:58:59Z No. of bitstreams: 1 2017_JuanGabrielBastidasMartinez.pdf: 5199470 bytes, checksum: b6ce6ef18ce495323f27268668ca254b (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-04-12T17:20:02Z (GMT) No. of bitstreams: 1 2017_JuanGabrielBastidasMartinez.pdf: 5199470 bytes, checksum: b6ce6ef18ce495323f27268668ca254b (MD5) / Made available in DSpace on 2018-04-12T17:20:02Z (GMT). No. of bitstreams: 1 2017_JuanGabrielBastidasMartinez.pdf: 5199470 bytes, checksum: b6ce6ef18ce495323f27268668ca254b (MD5) Previous issue date: 2018-04-12 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq). / A disposição final dos resíduos sólidos de forma ambientalmente e tecnicamente correta é um desafio mundial. No Brasil a lei 12.305 de 2010 teve por objetivo regulamentar esta disposição a fim de preservar o meio ambiente. O presente estudo teve como principal objetivo analisar a possibilidade técnica de disposição dos resíduos industriais provenientes das Estações de Tratamento de Água (lodos de ETA) e de rejeitos do beneficiamento de ferro em camadas de revestimento de pavimentos, com fins rodoviários. Além disto, se estudo uma técnica alternativa de fabricação do asfalto modificado com borracha proveniente dos pneus usados. A solução proposta contemplou a incorporação de diferentes teores dos resíduos finos na matriz do ligante asfáltico CAP 50/70. Em princípio, foram realizados ensaios químicos e mineralógicos para determinar as principais caraterísticas dos materiais alternativos. Em seguida, foram realizados dois grupos de estudo, o primeiro com a incorporação do fíler convencional tipo cal e fíleres alternativos (lodos de ETA e os rejeitos de minério de ferro RMF) e o segundo grupo com asfaltos modificados com elastômeros do tipo borracha na forma convencional (AB8) e com um composto de borracha por meio de um fíler estabilizador do tipo cal (AB CB). Os asfaltos modificados foram submetidos a ensaios clássicos de caraterização física de asfaltos e reológicos nas condições antes e após o envelhecimento Rolling Thin Film Oven Test RTOFT. Após esta etapa, foram feitas as dosagens de Concreto Betuminoso Usinado a Quente-CBUQ e Camada Porosa de Atrito-CPA para cada grupo de asfaltos modificados e realizados os ensaios de caraterização mecânica: resistência à tração, módulo de resiliência, creep estático, vida de fadiga por compressão diametral, resistência ao dano por umidade induzida e desgaste por abrasão Cântabro. Os resultados dos ligantes asfálticos modificados com os fíleres apresentaram maior consistência em função do teor adicionado, obtendo melhor desempenho mecânico nas misturas asfálticas CBUQ e CPA em termos da vida de fadiga e deformação permanente. No caso dos asfaltos modificados com o AB CB observaram-se aumentos da consistência e dos parâmetros reológicos, as misturas asfálticas CBUQ apresentaram melhor desempenho mecânico, devido às interações entre a superfície da borracha-asfalto, enquanto que as misturas CPA apresentaram menores desempenhos em relação às amostras de referência. Portanto, a adição dos materiais alternativos estudados nas misturas asfálticas pode ser considerada uma prática viável do ponto de vista técnico e ambiental, contribuindo com alternativas seguras de disposição final de resíduos. / The final disposal of solid waste in an environmentally and technically correct is a global The final disposal of solid waste in an environmentally and technically correct way is a global challenge. In Brazil, Law 12,305 of 2010 aims to regulate that in order to preserve the environment. This study aims to analyze the technical feasibility of the disposal of industrial waste generated in the Water Treatment Station (STW sludge) and residues originated by the use of iron in asphalt pavement. Also, an alternative technique of manufacturing modified rubber asphalt from used tires was studied. The proposed solution contemplates the incorporation of different contents of fine waste in asphalt cement AC 50-70. Initially, chemical and mineralogical tests were carried out to determine the main characteristics of the alternative materials. Two studies were performed, the first adding conventional mineral filler as lime and alternative mineral fillers (STW sludge and iron mining waste). The second group, using asphalts modified by elastomers as rubber (conventional form AC 8) and rubber compound (adding lime as stabilizer mineral filler ACR). The modified asphalts were subject of physical and rheological characterization tests in different conditions, before and after short-term aging in Rolling Thin Film Oven Test (RTOFT). Dense hot asphalt HMD and open-graded friction course (OGFC) trials were made for each group. Mechanical characterization tests were performed like tensile strength, modulus of resilience, static creep, fatigue life, diametral compression; resistance to damage induced and wear cantabro. The modified asphalts with the mineral fillers presented greater consistency depending on the added content, obtaining better mechanical performance in the asphalt mixtures in terms of fatigue and rutting. In the case of asphalts modified with ACR, an increase in the consistency and rheological parameters was observed. The HMD presented better mechanical performance due to the interactions between the surface of the rubber grain and the asphalt, while the draining mixtures presented lower performances in relation to the control samples. Therefore, the addition of the alternative materials studied in the asphalt mixtures can be considered as a viable practice from the technical and environmental point of view, contributing with safe alternatives of final waste disposal.
15

Caracterização de lodo gerado em estações de tratamento de água: perspectivas de aplicação agrícola

Botero, Wander Gustavo [UNESP] 18 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-18Bitstream added on 2014-06-13T18:38:44Z : No. of bitstreams: 1 botero_wg_me_araiq.pdf: 512153 bytes, checksum: b09f40251aab07169471a9ef398cbac7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho caracterizou lodos gerados em estações de tratamento de água de Jaboticabal-SP que utiliza cloreto férrico como floculante (FeCl3) e de Taquaritinga-SP e Manaus-AM, que utilizam sulfato de alumínio (Al2(SO4)3) como floculante. Foram feitas análises para avaliação da fertilidade, análise elementar e determinação de micro e macro-nutrientes e metais potencialmente tóxicos totais e biodisponíveis. Os resultados mostraram que os lodos apresentam potencial agrícola e elevados teores de matéria orgânica, sendo maiores para o lodo de Manaus-AM, que apresentou também maior grau de decomposição da matéria orgânica. Os teores de macro e micro-nutrientes e metais potencialmente tóxicos e biodisponiveis estão diretamente relacionados com o tipo de floculante utilizado no tratamento convencional da água e nas características da água bruta captada. As substâncias húmicas extraídas dos lodos de estações de tratamento de água (ETA) foram caracterizadas por análise elementar e análise térmica, apresentando para amostra de Manaus-AM maior grau de humificação. A estabilidade térmica se apresentou dependente do tipo de tratamento utilizado no lodo. Os estudos de complexação mostraram cinética de 10 minutos para íons cobre. Pela capacidade de complexação pode-se estabelecer a seguinte ordem de afinidade das SH por espécies metálicas:. Lodo de estação de tratamento de água de Jaboticabal-SP: Fe<Al<Ca<Cu<Mn<Mg;. Lodo de estação de tratamento de água de Taquaritinga-SP: Mn<Al<Ca<Cu<Fe<Mg; . Lodo de estação de tratamento de água de Manaus-AM: Mn<Al<Cu<Ca<Fe<Mg. As labilidade relativas tiveram o equilíbrio de troca atingido após 1 hora de contato e foram menores para lodos de Manaus-AM e o magnésio apresentou a menor labilidade relativa frente ao quelante dietilenotriaminopentaacético (DTPA)... / This work characterized sludge discharges from water treatment plants at the town Jaboticabal, São Paulo, Brazil using ferric chloride (FeCl3) as clotting and at the town Taquaritinga, São Paulo, Brazil and Manaus, Amazonas, Brazil, using aluminum sulfate (Al2 (SO4)3) as clotting. Tests were made for fertility, elemental analysis and determination of micro and macro-nutrients and potentially toxic metals. The results showed that the sludge present agricultural potential and high levels of organic matter, and higher for the sludge of Manaus-AM, which has also presented greater degree of decomposition of organic matter. The levels of macro and micronutrients and potentially toxic metals and bioavailable are directly related to the type of clotting used in the conventional treatment of water and the characteristics of water. Humic substances from the sludges generated in water treatment plants were characterized by elemental analysis and thermal analysis, presenting to sample Manaus-AM greater degree of humification. The thermal stability came dependent on the type of treatment used in the sludge. Studies of complexation showed kinetics of 10 minutes for copper ions. For the ability to complexation one can establish the following order of affinity of humic substances by metallic ions: . Sludge generated in water treatment plants of Jaboticabal-SP: Fe <Al <Ca <Cu <Mn <Mg;This work characterized sludge discharges from water treatment plants at the town Jaboticabal, São Paulo, Brazil using ferric chloride (FeCl3) as clotting and at the town Taquaritinga, São Paulo, Brazil and Manaus, Amazonas, Brazil, using aluminum sulfate (Al2 (SO4)3) as clotting. Tests were made for fertility, elemental analysis and determination of micro and macro-nutrients and potentially toxic metals. The results showed that the sludge present agricultural potential and high levels of organic matter, and higher...(Complete abstract, click electronic access below)
16

Ocorrência de compostos farmacológicos no Córrego da Onça, município de Três Lagoas - MS

Américo, Juliana Heloisa Pinê [UNESP] 01 October 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-10-01Bitstream added on 2014-06-13T19:59:00Z : No. of bitstreams: 1 americo_jhp_me_ilha.pdf: 1150853 bytes, checksum: 22eb0045ed6531c06a06108c015b424b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A contaminação dos ecossistemas aquáticos por compostos farmacológicos intensificou-se nos últimos anos devido ao aumento da produção e ao consumo desenfreado destas substâncias pela população. Estes compostos são encontrados em águas naturais e em efluentes de Estações de Tratamento de Esgoto (ETE), comprovando que sua presença em águas naturais é um indicativo de contaminação por águas residuárias de ETE. A presente pesquisa avaliou a ocorrência de compostos farmacológicos no Córrego da Onça, município de Três Lagoas (MS), bem como as relações específicas entre os pontos de monitoramento do corpo d’água. Assim, foram coletadas mensalmente, em um período de 12 meses amostras de água (1L) em seis pontos distintos representando diferentes seções do córrego. As amostras foram submetidas ao processo de extração em fase sólida e analisadas por cromatografia líquida de alta eficiência. Fármacos como atenolol, diclofenaco, ibuprofeno, naproxeno, paracetamol e piroxicam foram detectados nos pontos de coleta do corpo d’água. Com auxílio de uma ferramenta estatística, os pontos amostrais foram reunidos em duas classes, observando-se maior similaridade entre P1(Lagoa do Meio) e P2 (Lagoa Maior), e entre P4 (Jusante da ETE) e P5 (Novas Nascentes). Os resultados evidenciam a contaminação no córrego por compostos farmacológicos, possivelmente devido aos indícios de ligações clandestinas de esgoto sanitário e/ou não eficiência do sistema utilizado pela ETE do município de Três Lagoas. / The contamination of aquatic ecosystems by pharmacological compounds has intensified in recent years due to increased production and consumption of these substances by population. These compounds are found in natural waters and effluents from sewage treatment plants (WTP), confirming that their presence in natural waters is indicative of contamination by wastewater from WTP. This study investigated the occurrence of pharmacological compounds in the Stream of Onça at TrêsLagoas (MS), and the specific relationships between the monitoring points of the waterbody. Water samples were collected monthly, over a period of 12 months (water samples 1L) at six different points representing different sections of the stream. The samples were subjected to the process of solid phase extraction and analyzed by high performance liquid chromatography. Drugs such as atenolol, diclofenac, ibuprofen, naproxen, paracetamol and piroxicam were detected in the sampling points of the waterbody. A statistical tool aided to divide the sites into two classes, with a greater similarity between P1 (Middle Pond) and P2 (Major Pond), and between P4 (Downstream of WTP) and P5 (New springs). The results show that the stream contamination by pharmacological compoundsis an indication of illegal connections of sanitary sewer and/or inefficiency of the system used by WTP of Três Lagoas (MS).
17

Avaliação de macrófitas lemnáceas no polimento de águas residuárias e seu uso na cultura do feijão / Evaluation of lemnaceal macrophites in water polishing residues and their use in bean culture

Lima, Rafael dos Santos 16 February 2018 (has links)
Submitted by RAFAEL DOS SANTOS LIMA (rafaelsantosnatureza@yahoo.com.br) on 2018-04-13T13:55:33Z No. of bitstreams: 1 Dissertação Rafael_9_Banca_ 5 3_FINALcom ficha.pdf: 1446594 bytes, checksum: 32e7e796d1433450c73715d155faef1b (MD5) / Approved for entry into archive by Maria Lucia Martins Frederico null (mlucia@fca.unesp.br) on 2018-04-16T11:46:32Z (GMT) No. of bitstreams: 1 lima_rs_me_botfca.pdf: 1426623 bytes, checksum: a5bfebbdd6fbee2ca22ec77b48e3cf2d (MD5) / Made available in DSpace on 2018-04-16T11:46:32Z (GMT). No. of bitstreams: 1 lima_rs_me_botfca.pdf: 1426623 bytes, checksum: a5bfebbdd6fbee2ca22ec77b48e3cf2d (MD5) Previous issue date: 2018-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A necessidade de preservação e uso racional da água é notória e pertinente. Esta reeducação também está associada ao uso de fontes alternativas, como a utilização de efluentes tratados (águas residuárias), para fins menos nobres, ou seja, aqueles nos quais não se requer água potável. É importante estudar o uso de novos insumos com potencial agrícola, onde a aplicação de águas de qualidade inferior à potável pode se tornar uma alternativa promissora para a obtenção de nutrientes e de água para as plantas de forma econômica e com menos impactos ambientais. Conhecendo a importância e necessidade do reuso da água e uso de efluentes na agricultura, este trabalho teve como objetivo geral, analisar o efeito das macrófitas lemnáceas no polimento de águas residuárias, bem como o uso dessa água na irrigação da cultura do feijão. O experimento foi realizado em casa de vegetação não climatizada no Departamento de Solos e Recursos Ambientais da FCA, UNESP, na cidade de Botucatu – SP. O cultivar utilizado foi o feijão IPR Andorinha e a macrófita aquática lamnácea utilizada foi a espécie Lemnas minor. Observou-se no presente experimento a remoção de 59% dos sólidos totais (ST) presentes na água residuária, podendo afirmar que esta redução está associada à hidrólise da matéria orgânica particulada, sedimentação e usos de macrófitas lamnáceas. No presente trabalho obtive-se uma redução de 74% na demanda química de oxigênio (DQO) em um tempo de detenção hidráulica (TDH) de 10 dias. A utilização de Lemnas minor no presente experimento foi significativa e eficaz no polimento da água residuária, pois a removeu 86% de fósforo (P). A irrigação com água residuária teve efeito significativo (p ≤ 0,05) no conteúdo de macro e micronutrientes no feijão, indicando que esta cultura tem capacidade de absorver e tolerar a utilização na irrigação de água residuária com e sem polimento. O índice de cor verde das folhas foi significativamente maior (p ≤ 0,05), aproximadamente 17,10%, no tratamento irrigado com água residuária com polimento em relação ao irrigado com água de abastecimento (potável). Enquanto que a água residuária sem polimento se assemelhou a ambas as formas de irrigação anteriores.
18

Reciclagem do lodo de estação de tratamento de água : produção de coagulante por lixiviação ácida

Dandolini, Ivana January 2014 (has links)
A conversão do lodo em coagulante é uma das práticas considerada adequada para minimizar o impacto ambiental de destinação do lodo. A solubilização dos coagulantes e sua reciclagem permitem minimizar os custos e os problemas associados à disposição final dos lodos gerados em ETAs. Os processos de recuperação dos coagulantes podem ser realizados por via ácida, via alcalina e via extração com solventes orgânicos por complexação/quelação. Entretanto, a recuperação por via ácida (Processo Fulton) é a que tem se demonstrado a mais viável, tanto técnica como economicamente. Assim, o objetivo desse trabalho foi avaliar a possibilidade de recuperação de coagulante a partir do lodo de uma estação de tratamento de água. Optou-se pelo processo de recuperação por via ácida, utilizando-se ácido sulfúrico. A metodologia do trabalho envolveu: (a) a caracterização do lodo da ETA; (b) ensaios práticos de acidificação para recuperação de um coagulante misto à base de ferro e alumínio (considerando-se o uso de lodo “in natura” na forma pastoso/líquida, lodo seco a 105ºC e lodo calcinado a 500ºC; (c) análises dos coagulantes obtidos; (d) caracterização do lodo residual de acordo com NBR 10.004 (2004); e (e) realização de testes de tratamento de água com o coagulante obtido à partir do lodo de forma comparativa com o coagulante em uso atualmente na ETA. Os resultados demonstram que a recuperação do coagulante somente foi efetiva após a calcinação do lodo da ETA, para a eliminação da matéria orgânica presente. A aplicação do coagulante reciclado no tratamento de água foi igualmente eficiente ao coagulante tradicionalmente empregado, ambos atendendo a qualidade da água exigida na Portaria 2914/2011. / The conversion of coagulant sludge is one of the practices considered adequate to minimize the environmental impact of disposal of sludge. The solubilization of coagulants and enable their recycling to minimize the costs and problems associated with the disposal of sludge generated in ETAs. The coagulant recovery process may be performed by acid- route, and route via alkaline extraction by organic complexing / chelating solvents. However, the recovery by acid pathway (Case Fulton) is the one that has shown the most feasible , both technically and economically . The objective of this study was to evaluate the recoverability of coagulant sludge from a water treatment plant. We chose the recovery process by acid pathway, using sulfuric acid. The methodology of work involved : ( a) the characterization of sludge by ETA; ( b ) practical tests acidification recovery of a mixed coagulant based on iron and aluminum (considering the use of sludge " in natura " in paste / liquid form , dried sludge at 105 º C and calcined sludge at 500 º C ); ( c ) analyzes of coagulants obtained; ( d ) characterization of residual sludge according to NBR 10004 (2004 ); and (e ) conducting tests with water treatment coagulant obtained from the sludge in comparison with the coagulant in use today in the ETA . The results demonstrate that recovery of coagulant was only effective after calcination of the sludge ETA for the removal of organic matter. The application of recycled coagulant in water treatment was also effective in traditional coagulant employee, serving both the water quality required in Ordinance 2914/2011.
19

Reciclagem do lodo de estação de tratamento de água : produção de coagulante por lixiviação ácida

Dandolini, Ivana January 2014 (has links)
A conversão do lodo em coagulante é uma das práticas considerada adequada para minimizar o impacto ambiental de destinação do lodo. A solubilização dos coagulantes e sua reciclagem permitem minimizar os custos e os problemas associados à disposição final dos lodos gerados em ETAs. Os processos de recuperação dos coagulantes podem ser realizados por via ácida, via alcalina e via extração com solventes orgânicos por complexação/quelação. Entretanto, a recuperação por via ácida (Processo Fulton) é a que tem se demonstrado a mais viável, tanto técnica como economicamente. Assim, o objetivo desse trabalho foi avaliar a possibilidade de recuperação de coagulante a partir do lodo de uma estação de tratamento de água. Optou-se pelo processo de recuperação por via ácida, utilizando-se ácido sulfúrico. A metodologia do trabalho envolveu: (a) a caracterização do lodo da ETA; (b) ensaios práticos de acidificação para recuperação de um coagulante misto à base de ferro e alumínio (considerando-se o uso de lodo “in natura” na forma pastoso/líquida, lodo seco a 105ºC e lodo calcinado a 500ºC; (c) análises dos coagulantes obtidos; (d) caracterização do lodo residual de acordo com NBR 10.004 (2004); e (e) realização de testes de tratamento de água com o coagulante obtido à partir do lodo de forma comparativa com o coagulante em uso atualmente na ETA. Os resultados demonstram que a recuperação do coagulante somente foi efetiva após a calcinação do lodo da ETA, para a eliminação da matéria orgânica presente. A aplicação do coagulante reciclado no tratamento de água foi igualmente eficiente ao coagulante tradicionalmente empregado, ambos atendendo a qualidade da água exigida na Portaria 2914/2011. / The conversion of coagulant sludge is one of the practices considered adequate to minimize the environmental impact of disposal of sludge. The solubilization of coagulants and enable their recycling to minimize the costs and problems associated with the disposal of sludge generated in ETAs. The coagulant recovery process may be performed by acid- route, and route via alkaline extraction by organic complexing / chelating solvents. However, the recovery by acid pathway (Case Fulton) is the one that has shown the most feasible , both technically and economically . The objective of this study was to evaluate the recoverability of coagulant sludge from a water treatment plant. We chose the recovery process by acid pathway, using sulfuric acid. The methodology of work involved : ( a) the characterization of sludge by ETA; ( b ) practical tests acidification recovery of a mixed coagulant based on iron and aluminum (considering the use of sludge " in natura " in paste / liquid form , dried sludge at 105 º C and calcined sludge at 500 º C ); ( c ) analyzes of coagulants obtained; ( d ) characterization of residual sludge according to NBR 10004 (2004 ); and (e ) conducting tests with water treatment coagulant obtained from the sludge in comparison with the coagulant in use today in the ETA . The results demonstrate that recovery of coagulant was only effective after calcination of the sludge ETA for the removal of organic matter. The application of recycled coagulant in water treatment was also effective in traditional coagulant employee, serving both the water quality required in Ordinance 2914/2011.
20

Avaliação experimental para melhoria da eficiência da Ete do Conjunto Habitacional Ignez Andreazza em Areias (Compesa) através de estudo em Escala Piloto

SILVA, Maria de Fátima Barbosa da January 2005 (has links)
Made available in DSpace on 2014-06-12T18:07:06Z (GMT). No. of bitstreams: 2 arquivo7865_1.pdf: 950809 bytes, checksum: 017c08f8a7e33fa61e9eb18bba06f0e7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Devido ao interesse social e ambiental em se expandir o número de comunidades atendidas por sistemas de esgotamento sanitário, constitui-se também um desafio projetar, construir e operar estações de tratamento eficientes e econômicas. Com base nesses argumentos e através de análises preliminares, escolheu-se para estudo, uma estação de tratamento de esgotos domésticos operada pela COMPESA que atende a aproximadamente 12.320 habitantes residentes no Conjunto Habitacional Ignez Andreazza, o maior da América Latina, situado em Areias-Recife-PE. Nesta estação de tratamento de efluentes (ETE) foi observado um baixo rendimento na remoção da Demanda Bioquímica de Oxigênio (DBO) em relação ao esperado em projeto, assim como problemas de recirculação e de baixa concentração de lodos ativados no tanque de aeração. Desta forma, este trabalho contribuiu para a melhoria do funcionamento desta ETE a partir de informações de monitoramento da mesma e estudos em unidades piloto. Foi realizada inicialmente uma avaliação através da caracterização dos efluentes e afluentes da mesma, utilizando a metodologia do Standard Methods for Water and Wastewater Examination (APHA et al., 1985). Foram analisados três pontos do sistema: entrada após a caixa de areia, o tanque de aeração e a saída do decantador. Em seguida foi realizado um estudo do processo de tratamento em uma unidade piloto constituída de um tanque de 21 litros, dotado de aeração por pedras porosas e um decantador, ambos de acrílico. A recirculação do lodo e a alimentação do substrato sintético foram realizadas utilizando uma bomba peristáltica. Foi também realizada uma avaliação do regime de escoamento nesta unidade piloto, através da técnica de DTR utilizando NaCl como traçador. Uma análise da influência da recirculação na performance do sistema pode ser realizada através de um segundo monitoramento dos mesmos pontos e tomando como base os resultados do primeiro estudo. A avaliação da cinética foi baseada em dados obtidos por respirometria, da degradação da matéria orgânica. Foi observada uma redução de 75% dos sólidos totais dissolvidos e uma remoção da DQO de cerca de 80%. No estudo no reator piloto, foi constatado um tempo de residência médio (tm) de 8,15h com variância (&#963;2) de 50,35 h2 para um tempo de retenção hidráulico teórico (TRH) de 10,5h. Aplicando-os no modelo de tanques em série, verificou-se que seriam necessários dois tanques ideais em série para modelar o reator real. Na operação do sistema piloto com a biomassa, após a estabilização do sistema, foram verificados valores de eficiências de 90 e 92% para a DBO e DQO respectivamente. No estudo cinético, foram utilizados como parâmetros a DQO e em seguida a concentração de biomassa. Devido a problemas de homogeneidade e representatividade na amostragem foi utilizada a técnica da determinação da Taxa de Consumo de Oxigênio (TCO) para se monitorar o avanço da degradação. Seis experimentos para determinação da TCO permitiram obter gráficos da TCO versus tempo, encontrando-se pelo método de cálculo integral um valor médio para a constante de velocidade (k) igual a 2,6, tendo sido considerado a reação como de 1ª ordem. Como reflexo do trabalho de monitoramento, a ETE estudada superou a eficiência de remoção de DBO estimada em projeto (94%) para 96% uma vez ativada a recirculação de lodo para o tanque aerado e realizadas as modificações sugeridas

Page generated in 0.1429 seconds