• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • Tagged with
  • 20
  • 20
  • 20
  • 13
  • 13
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação dos efeitos do recebimento do lodo de estação de tratamento de água em sistema de tratamento de esgoto pelo processo de lodo ativado com aeração prolongada. / Evaluation of the effects of accepting water treatment plant residual at a wastewater system using prolongated aeration activated-sludge process.

Asada, Lucia Naomi 25 May 2007 (has links)
Nesta pesquisa o principal objetivo foi estudar a influência da disposição de lodo gerado em estação de tratamento de água (ETA), que utiliza sulfato de alumínio como coagulante, nos processos biológicos de tratamento de esgoto por lodo ativado com aeração prolongada. Para isso, uma estação piloto de fluxo contínuo foi operada com idade do lodo de 25 dias em duas condições: inicialmente alimentada somente com esgoto bruto e posteriormente com adição de lodo de ETA à base de alumínio de modo a haver acréscimo nos sólidos em suspensão (SS) do esgoto em 25, 50 e 100 mg/L. Os resultados obtidos mostraram que a principal conseqüência foi o aumento na produção de sólidos do sistema (acréscimos médios de 4,6% com 25 mg/L, 37,7% com 50 mg/L e 41,0% com 100 mg/L) e, portanto, na concentração média de SS no tanque de aeração, no decantador secundário e no lodo produzido em excesso. Como o decantador secundário operou com taxa de aplicação de sólidos abaixo da taxa limite não houve problema de arraste de sólidos pelo efluente final. Não houve interferências na remoção de DBO5,20 (eficiência de remoção acima de 94%). O teste de consumo de oxigênio específico (TCOa/SSV) e o exame microscópico do lodo não apontaram possíveis efeitos tóxicos desse lodo à microfauna existente. Não houve inibição no processo de nitrificação (eficiência média de remoção de nitrogênio Kjeldhal Total e de nitrogênio amoniacal acima de 95%). Houve aumento na concentração de DQO e de SS no efluente final pela própria contribuição do lodo da ETA sobre esses parâmetros. A remoção de fósforo foi observada apenas na forma solúvel com dosagem de 25 mg/L e 50 mg/L (eficiências de remoção de 9,1% e de 21,9% respectivamente). Esses resultados apontam que a disposição do lodo de ETA a base de alumínio em sistema de lodo ativado pode ser realizada sem interferências negativas sobre esses processos biológicos aeróbios. / The main purpose of this research was to study the influence of an alum-coagulated water treatment plant (WTP) sludge on the biological processes of wastewater treatment using extended aeration activated-sludge process. For this, a continuousflow activated-sludge pilot plant was operated at solids retention time (SRT) value of 25 day under two conditions: initially, it was feeded only with sewage and next dosed with alum sludge in way to have an addition about 25, 50 and 100 mg of suspended solids (SS) per liter of incoming sewage. The results showed that the main consequence was the increase of solids production (average addition of 4,6% at 25 mg/L, 37,7% at 50 mg/L and 41% at 100 mg/L dosages) and therefore an increasing of average concentration of SS in aeration tank, secondary clarifier and wasteactivated sludge. As the secondary clarifier operated under solids loading rate limit no solids were discharged in the clarifier effluent. There was no interference on BOD5 removal (removal efficiency above 94%). The specific oxygen uptake rate (SOUR) and the microscopic observations did not show any possible toxic effects to the microbial population inhabiting the activated sludge system. There was no inhibition in nitrification process (average efficiency of Total Kjeldahl nitrogen and ammonia nitrogen removal above 95%). There was an increase of COD and SS in final effluent due to contribution of WTP residuals on these parameters. Phosphorus removal was observed only in soluble form with doses of 25 mg/L and 50 mg/L (removal efficiency of 9,1% and 21,9% respectively). These results indicate that disposal of WTP alum sludge in activated-sludge system can be done without any adverse effects on these aerobic biological processes.
12

Modelo conceitual de seleção de tecnologias de tratamento de água para abastecimento de comunidades de pequeno porte / Conceptual selection model of technologies of water treatment for the supply of small communities

Sabogal Paz, Lyda Patricia 28 September 2007 (has links)
Os investimentos no setor de água potável no Brasil, apesar de significativos, ainda não apresentam os resultados esperados na melhoria da saúde e da qualidade de vida da população, especialmente nas pequenas comunidades do país. A aplicação de recursos continuará limitada enquanto não forem fortalecidos os aspectos técnicos, econômicos, institucionais, ambientais, sociais e culturais que permitam a seleção de obras sanitárias eficientes e sustentáveis. Neste contexto, foi desenvolvido um modelo conceitual de seleção de tecnologias de tratamento de água constituído por 17 sub-níveis que progressivamente \"filtram\" as opções tecnológicas aplicáveis em comunidades brasileiras inferiores a 20.000 habitantes. Os aspectos envolvidos no modelo se relacionam: i) ao risco presente na fonte de abastecimento superficial; ii) à eficiência das tecnologias para eliminar ou reduzir o risco a valores de acordo à Portaria no 518 (2004); iii) ao tratamento, aproveitamento e disposição dos resíduos gerados e iv) aos custos dos sistemas com vazões de projeto de 10 a 40 L/s. As principais conclusões da pesquisa foram: i) a aplicabilidade do modelo está restrita à estações de tratamento de água - ETAs que cumprem todos seus requisitos de domínio, ii) os valores-limite das variáveis de risco podem conduzir o engenheiro a uma seleção preliminar das possíveis alternativas de tratamento; entretanto, somente a partir de estudos de tratabilidade da água e de testes em instalação piloto será possível definir a ETA mais conveniente, iii) as seleções das tecnologias para tratamento, aproveitamento e disposição do resíduo não devem ser avaliadas de forma independente às empregadas nas ETA; iv) Os custos calculados pelo modelo dificilmente podem ser comparados com sistemas já existentes; v) os resultados do modelo variam em função dos dados de entrada; assim, o usuário deve ter consciência da qualidade da informação fornecida para obter resultados satisfatórios. / Despite being significant the investments in the brazilian drinking water sector still have not presented the expected results regarding the improvement of both health and population\'s life quality, especially in the small communities of the country. The application of resources will continue limited while the technical, economical, institutional, environmental, social and cultural aspects that allow for the selection of efficient and maintainable sanitary works are not strengthened. In this context, a conceptual model to select technologies for water treatment has been developed. It consists of 17 sub-levels that progressively \"filter\" the applicable technological options in brazilian communities of under 20.000 inhabitants. The aspects involved are related to: i) the risk present in the source of superficial supply; ii) the efficiency of the technologies to lither eliminate or reduce the risk to the values according law no 518 (2004); iii) the treatment, use and disposition of the generated residues and iv) the costs of the systems with project flows from 10 L/s to 40L/s. The main conclusions of the research were: i) the applicability of the model is restricted to water treatment plants - WTPs that accomplish all their domain requirements, ii) the limit values of the risk variables can lead the engineer to a preliminary selection of the possible treatment alternatives; however, only from studies of water treatment and tests in pilot installations it will be possible to define the most convenient WTP, iii) the selections of the technologies for treatment, use and disposition of residues should not be appraised in an independent way of the ones employed in WTPs, iv) the costs calculated by the model can hardly be compared with systems already existent; v) the results of the model vary in function of the input data; therefore, the user should be aware of the quality of the information supplied to obtain satisfactory results.
13

Avaliação dos efeitos do recebimento do lodo de estação de tratamento de água em sistema de tratamento de esgoto pelo processo de lodo ativado com aeração prolongada. / Evaluation of the effects of accepting water treatment plant residual at a wastewater system using prolongated aeration activated-sludge process.

Lucia Naomi Asada 25 May 2007 (has links)
Nesta pesquisa o principal objetivo foi estudar a influência da disposição de lodo gerado em estação de tratamento de água (ETA), que utiliza sulfato de alumínio como coagulante, nos processos biológicos de tratamento de esgoto por lodo ativado com aeração prolongada. Para isso, uma estação piloto de fluxo contínuo foi operada com idade do lodo de 25 dias em duas condições: inicialmente alimentada somente com esgoto bruto e posteriormente com adição de lodo de ETA à base de alumínio de modo a haver acréscimo nos sólidos em suspensão (SS) do esgoto em 25, 50 e 100 mg/L. Os resultados obtidos mostraram que a principal conseqüência foi o aumento na produção de sólidos do sistema (acréscimos médios de 4,6% com 25 mg/L, 37,7% com 50 mg/L e 41,0% com 100 mg/L) e, portanto, na concentração média de SS no tanque de aeração, no decantador secundário e no lodo produzido em excesso. Como o decantador secundário operou com taxa de aplicação de sólidos abaixo da taxa limite não houve problema de arraste de sólidos pelo efluente final. Não houve interferências na remoção de DBO5,20 (eficiência de remoção acima de 94%). O teste de consumo de oxigênio específico (TCOa/SSV) e o exame microscópico do lodo não apontaram possíveis efeitos tóxicos desse lodo à microfauna existente. Não houve inibição no processo de nitrificação (eficiência média de remoção de nitrogênio Kjeldhal Total e de nitrogênio amoniacal acima de 95%). Houve aumento na concentração de DQO e de SS no efluente final pela própria contribuição do lodo da ETA sobre esses parâmetros. A remoção de fósforo foi observada apenas na forma solúvel com dosagem de 25 mg/L e 50 mg/L (eficiências de remoção de 9,1% e de 21,9% respectivamente). Esses resultados apontam que a disposição do lodo de ETA a base de alumínio em sistema de lodo ativado pode ser realizada sem interferências negativas sobre esses processos biológicos aeróbios. / The main purpose of this research was to study the influence of an alum-coagulated water treatment plant (WTP) sludge on the biological processes of wastewater treatment using extended aeration activated-sludge process. For this, a continuousflow activated-sludge pilot plant was operated at solids retention time (SRT) value of 25 day under two conditions: initially, it was feeded only with sewage and next dosed with alum sludge in way to have an addition about 25, 50 and 100 mg of suspended solids (SS) per liter of incoming sewage. The results showed that the main consequence was the increase of solids production (average addition of 4,6% at 25 mg/L, 37,7% at 50 mg/L and 41% at 100 mg/L dosages) and therefore an increasing of average concentration of SS in aeration tank, secondary clarifier and wasteactivated sludge. As the secondary clarifier operated under solids loading rate limit no solids were discharged in the clarifier effluent. There was no interference on BOD5 removal (removal efficiency above 94%). The specific oxygen uptake rate (SOUR) and the microscopic observations did not show any possible toxic effects to the microbial population inhabiting the activated sludge system. There was no inhibition in nitrification process (average efficiency of Total Kjeldahl nitrogen and ammonia nitrogen removal above 95%). There was an increase of COD and SS in final effluent due to contribution of WTP residuals on these parameters. Phosphorus removal was observed only in soluble form with doses of 25 mg/L and 50 mg/L (removal efficiency of 9,1% and 21,9% respectively). These results indicate that disposal of WTP alum sludge in activated-sludge system can be done without any adverse effects on these aerobic biological processes.
14

Modelo conceitual de seleção de tecnologias de tratamento de água para abastecimento de comunidades de pequeno porte / Conceptual selection model of technologies of water treatment for the supply of small communities

Lyda Patricia Sabogal Paz 28 September 2007 (has links)
Os investimentos no setor de água potável no Brasil, apesar de significativos, ainda não apresentam os resultados esperados na melhoria da saúde e da qualidade de vida da população, especialmente nas pequenas comunidades do país. A aplicação de recursos continuará limitada enquanto não forem fortalecidos os aspectos técnicos, econômicos, institucionais, ambientais, sociais e culturais que permitam a seleção de obras sanitárias eficientes e sustentáveis. Neste contexto, foi desenvolvido um modelo conceitual de seleção de tecnologias de tratamento de água constituído por 17 sub-níveis que progressivamente \"filtram\" as opções tecnológicas aplicáveis em comunidades brasileiras inferiores a 20.000 habitantes. Os aspectos envolvidos no modelo se relacionam: i) ao risco presente na fonte de abastecimento superficial; ii) à eficiência das tecnologias para eliminar ou reduzir o risco a valores de acordo à Portaria no 518 (2004); iii) ao tratamento, aproveitamento e disposição dos resíduos gerados e iv) aos custos dos sistemas com vazões de projeto de 10 a 40 L/s. As principais conclusões da pesquisa foram: i) a aplicabilidade do modelo está restrita à estações de tratamento de água - ETAs que cumprem todos seus requisitos de domínio, ii) os valores-limite das variáveis de risco podem conduzir o engenheiro a uma seleção preliminar das possíveis alternativas de tratamento; entretanto, somente a partir de estudos de tratabilidade da água e de testes em instalação piloto será possível definir a ETA mais conveniente, iii) as seleções das tecnologias para tratamento, aproveitamento e disposição do resíduo não devem ser avaliadas de forma independente às empregadas nas ETA; iv) Os custos calculados pelo modelo dificilmente podem ser comparados com sistemas já existentes; v) os resultados do modelo variam em função dos dados de entrada; assim, o usuário deve ter consciência da qualidade da informação fornecida para obter resultados satisfatórios. / Despite being significant the investments in the brazilian drinking water sector still have not presented the expected results regarding the improvement of both health and population\'s life quality, especially in the small communities of the country. The application of resources will continue limited while the technical, economical, institutional, environmental, social and cultural aspects that allow for the selection of efficient and maintainable sanitary works are not strengthened. In this context, a conceptual model to select technologies for water treatment has been developed. It consists of 17 sub-levels that progressively \"filter\" the applicable technological options in brazilian communities of under 20.000 inhabitants. The aspects involved are related to: i) the risk present in the source of superficial supply; ii) the efficiency of the technologies to lither eliminate or reduce the risk to the values according law no 518 (2004); iii) the treatment, use and disposition of the generated residues and iv) the costs of the systems with project flows from 10 L/s to 40L/s. The main conclusions of the research were: i) the applicability of the model is restricted to water treatment plants - WTPs that accomplish all their domain requirements, ii) the limit values of the risk variables can lead the engineer to a preliminary selection of the possible treatment alternatives; however, only from studies of water treatment and tests in pilot installations it will be possible to define the most convenient WTP, iii) the selections of the technologies for treatment, use and disposition of residues should not be appraised in an independent way of the ones employed in WTPs, iv) the costs calculated by the model can hardly be compared with systems already existent; v) the results of the model vary in function of the input data; therefore, the user should be aware of the quality of the information supplied to obtain satisfactory results.
15

Estudos comparativos de floculação hidráulica para águas de abastecimento em reatores de fluxo ascendente dotados de seixos rolados e de materiais sintéticos / Comparative studies of hydraulic flocculation for supplying water using up flow reactors dowered with stones and other with synthetic materials

Lima, Milma Roza de 17 August 2018 (has links)
Orientador: Ruben Bresaola Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T00:58:33Z (GMT). No. of bitstreams: 1 Lima_MilmaRozade_M.pdf: 5486982 bytes, checksum: f022781b42a125131286f8b2864cc00b (MD5) Previous issue date: 2010 / Resumo: A floculação em meio granular fixo desperta bastante interesse por suas possibilidades de aplicação, principalmente em estações de tratamento de água de pequeno porte (vazões menores que 10 L.s-1), devido à sua eficiência, compacidade e baixo custo. No entanto, o reduzido volume de vazios proporcionado pelo meio granular quando comparado ao dos materiais sintéticos favorece o aumento excessivo da perda de carga imposta ao escoamento e consequentemente o inconveniente de freqüentes necessidades de limpeza. Diante da necessidade de atenuar ou mesmo eliminar tais considerações operacionais, este trabalho propõe estudos comparativos de eficiência de floculação hidráulica em meios granulares fixos em sistemas pilotos constituídos por seixos rolados de diferentes granulometrias e outro por manta não tecida (PP) e esferas sólidas (? 9 mm, PS). Os ensaios foram realizados com água coagulada da ETA Bragança Paulista (SABESP) para taxas de aplicação superficial de 50, 75, 100, 150, 180, 200, 250, 300 e 350 m3.m-2.dia-1, onde foram determinadas as condições operacionais, o período de floculação e a evolução da perda de carga total. Os resultados mostraram que a porosidade mais elevada apresentada pelo sistema piloto constituído de manta sintética e esferas sólidas favoreceu o aumento da taxa de colisões entre as partículas coloidais, o que permitiu a geração de manta de lodo, a formação de escoamento laminar, bem como, a facilidade de liberação do lodo retido para recuperação da carga hidráulica disponível / Abstract: The flocculation in fixed granular media arises plenty of interests in its possibility of applying, mainly in the water treatment plants of small size (flow less than 10 L.s-1), due to its efficiency, compactness and low cost. Nevertheless the reduced volume of voids provided by granular media as compared to the synthetic materials, collaborates to the excessive increasing of head loss imposed to the flowing off and consequently the inconvenient of frequent needs of cleaness. Before the need of reduction or even elimination of the such operational considerations, this work suggests comparative studies of the hydraulic flocculation efficiency by fixed granular media in the pilot systems composed by the stones from different granulametries or another one by non woven synthetic fabric (PP) and solid spheres (? 9mm, PS). The tests have been made with coagulated water from ETA Bragança Paulista (SABESP) to superficial applying rates of 50, 75, 100, 150, 180, 200, 250, 300 and 350 m3.m-2.dia-1, where they were determined the working conditions, flocculation time and evolution of head loss. The results have shown that the most elevated porosity presented in the pilot system composed by non woven synthetic fabric and solid spheres collaborated to the increasing of the collision rates among the particles, which allowed the generation of sludge blanket, the formation of laminar flow such as the facility of discharging of retained sludge for recovery of the hydraulic load available / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
16

Potencial de aplicação do processo fotocatalítico na água do Rio Piracicaba = Photocatalytic process applied to the Piracicaba river's water / Photocatalytic process applied to the Piracicaba river's water

Claro, Elis Marina Turini, 1985- 22 August 2018 (has links)
Orientadores: Peterson Bueno de Moraes, Edério Dino Bidóia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia / Made available in DSpace on 2018-08-22T03:26:05Z (GMT). No. of bitstreams: 1 Claro_ElisMarinaTurini_M.pdf: 2348408 bytes, checksum: 866377db43cbdf888b73040dcfb89167 (MD5) Previous issue date: 2013 / Resumo: O uso de tecnologias alternativas de tratamento de água contribui para suprimir limitações e inconvenientes oriundos dos processos convencionais de tratamento. Dentre estas, destaca-se a fotocatálise heterogênea, a qual foi utilizada nesse trabalho visando redução da concentração de matéria orgânica, nitrito, inativação de coliformes totais e Escherichia coli da água do rio Piracicaba, para ser utilizada como água de entrada em uma ETA. Avaliou-se o processo fotocatalítico utilizando TiO2 P25 e ZnO comercial além de fotocatalisadores dopados sintetizados (SiZnO, N-SiZnO, F-N-SiZnO, N-SiZnO + NH4Cl, TiO2 + NaOH, TiO2 + NH4OH e TiO2 + NH4F) nas concentrações 1,0 g l-1 e 0,5 g l-1, submetidos à ação de três fontes de radiação distintas (lâmpada de vapor de mercúrio de 250 W, simulador solar e um reator utilizando LED UV de 0,12 W), avaliando-se a toxicidade com sementes de alface (Lactuca sativa). Os resultados demonstraram que em 0,5 g L-1 dos fotocatalisadores, melhor concentração estudada, todos apresentaram atividade fotocatalítica, sendo que nenhum dos sintetizados foram capazes de proporcionar degradação superior ao TiO2 e ao ZnO para tratamento da água do rio. Os melhores resultados dos fotocatalisadores sintetizados foram obtidos com o N-SiZnO para remoção de matéria orgânica em 60 minutos (37% para vapor de mercúrio) e inativação de micro-organismos maiores que 4,0 log para coliformes totais e E. coli, utilizando vapor de mercúrio em 30 minutos de tratamento, além de apresentar a menor fitotoxicidade para as três fontes de radiação. A lâmpada de vapor de mercúrio foi a que apresentou resultados mais satisfatórios em 60 minutos de tratamento. Para o nitrito, não houve redução nas concentrações em 60 minutos de tratamento em relação à inicial, porém, ocorreu aumento nos valores de nitrito em 15 minutos de tratamento, indicando provável oxidação a nitrato. A fotocatálise heterogênea poderia ser aplicada para utilização como tratamento de água de entrada de uma ETA convencional de ciclo completo, entretanto, devido à necessidade de separação dos fotocatalisadores da água e aumento da toxicidade, é recomendado uma minuciosa análise de custo x benefício / Abstract: The use of alternative technologies for water treatment contributes to suppress limitations and disadvantages of conventional processes. Among the promising technologies, there is heterogeneous photocatalysis which was used in this work in order to reduce the concentration of organic matter, nitrite, inactivation of total coliforms and Escherichia coli in samples of water from Piracicaba River, to be used as primary feed for a Municipal Water Treatment Plant (MWTP). We evaluated the photocatalytic process using TiO2 P25 (Degussa) and commercial ZnO as well as synthesized photocatalysts doped (SiZnO, N-SiZnO, F-N-SiZnO, N-SiZnO + NH4Cl, TiO2 + NaOH, TiO2 + NH4OH and TiO2 + NH4F) in concentrations of 1.0 g L-1 and 0.5 g L-1 irradiated under three different sources (high-pressure mercury vapor lamp, solar simulator and UVLED) and monitoring the toxicity with lettuce seeds (Lactuca sativa). The results showed that 0.5 g L-1 was the best concentration; at this value all photocatalysts presented photo-activity whereas none of the synthesized was able to overcome the degradation rates observed by the TiO2 and ZnO. The best results were obtained by photocatalysts synthesized with N-SiZnO irradiated by the high-pressure mercury lamp: 37% of organic matter removal (60 minutes) and inactivation of microorganisms higher than 4.0 log for total coliforms and E. coli (after 30 minutes of treatment), besides to result in the smallest phytotoxicity of the three radiation sources. The use of mercury vapor lamp showed the best results for 60 minutes of treatment time. No fall in the nitrite concentration was obtained during 60 minutes of treatment although a rise in the nitrite concentration has been observed in 15 minutes, which may indicate probable oxidation to nitrate. The proposed photocatalysts could be applied for treating inlet water's at MWTP; however, due to necessity of separation of solution water-photocatalyst and due to small increase of values observed in the toxicity tests, a detailed cost-benefit analysis is recommended / Mestrado / Tecnologia e Inovação / Mestra em Tecnologia
17

Ocorrência e remoção de contaminantes emergentes por tratamentos convencionais de água e esgoto / Occurrence and removal of emerging contaminants by conventional water and wastewater treatments

Pescara, Igor Cardoso, 1983- 26 August 2018 (has links)
Orientador: Wilson de Figueiredo Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-26T13:39:08Z (GMT). No. of bitstreams: 1 Pescara_IgorCardoso_D.pdf: 5286232 bytes, checksum: 74793adc4ea590e2eb8fdeb51a796399 (MD5) Previous issue date: 2014 / Resumo: Este trabalho teve como objetivo avaliar a eficiência dos tratamentos empregados em cinco estações de tratamento de esgoto (ETE) e duas estações de tratamento de água (ETA) na remoção dos hormônios endógenos estrona (E1), 17?-estradiol (E2), estriol (E3), testosterona (TTN) e progesterona (PROG), hormônios sintéticos 17a-etinilestradiol (EE2), dietilestilbestrol (DES), norgestrel (NGT) e mestranol (MEE), produtos de uso industrial bisfenol A (BPA), fenolftaleína (PhPh), n-nonilfenol (nNP), n-octilfenol (nOP) e triclosan (TCS), o fármaco cafeína (CAF) e o pesticida atrazina (ATZ). Foi possível quantificar BPA, E1, E3, CAF e ATZ em esgoto bruto e BPA, E1, CAF e ATZ em água bruta. Para cada composto, tanto os tratamentos realizados pelas ETE quanto os realizados pelas ETA apresentaram eficiências de remoção variáveis. A cafeína foi o composto-alvo mais frequentemente encontrado nas amostras, sendo escolhida como indicador químico para avaliar a eficiência dos tratamentos. Foi encontrada uma taxa média de 99% para a remoção de CAF pelas ETE, sendo as etapas com tratamentos biológicos as mais eficientes. Os tratamentos anaeróbios apresentaram remoções médias superiores a 80% na remoção de CAF, e os tratamentos aeróbios foram capazes de remover cerca de 20% da carga do composto. Nas ETE, os tratamentos de coagulação e desinfecção foram pouco eficientes nas remoções dos compostos-alvo. Já para as ETA, foram observadas remoções de até 80% de CAF pelos tratamentos empregados, sendo a etapa de coagulação a responsável pela maior remoção de CAF da água bruta. A etapa de filtração em carvão ativado apresentou eficiências de remoção menores que 10%, enquanto a desinfecção demonstrou baixa eficiência na remoção de CAF. Na cidade de São José do Rio Preto ¿ SP foi possível quantificar, ao menos uma vez, BPA, E1, E3, PhPh, CAF, TCS e ATZ em água superficial, BPA, TCS e CAF em água subterrânea e BPA, CAF e ATZ em água de abastecimento. / Abstract: Water and wastewater conventional treatments are often considered inefficient to remove micropollutants. The aim of this work was to evaluate the removal efficiency of the endogenous hormones estrone (E1), 17? estradiol (E2), estriol (E3), testosterone (TTN), and progesterone (PROG), the synthetic hormones 17a-ethinylestradiol (EE2), diethylstilbestrol (DES), norgestrel (NGT), and mestranol (MEE), the industrial chemicals bisphenol A (BPA), phenolphthalein (PhPh), n nonylphenol (nNP), n octylphenol (nOP), and triclosan (TCS), the pharmaceutical caffeine (CAF), and the pesticide atrazine (ATZ) by five wastewater treatment plants (WWTP) and two drinking water treatment plants (DWTP). The target compounds BPA, E1, E3, CAF, and ATZ were found in raw sewage, while BPA, E1, CAF, and ATZ in raw water. Both WWTP and DWTP treatments presented variable removal efficiency. Caffeine was the target compound more often detected in samples, thus it was chosen as a chemical indicator to evaluate treatment efficiencies. The average removal of CAF by WWTP was 99%, in which the biological treatment was more efficient. The anaerobic treatment presented an average removal of CAF above 80%, and around 20% for the aerobic treatments. Coagulation and disinfection treatments of WWTP showed low efficiency to remove the target compounds. DWTP treatment efficiency reached up to 80% removal, with coagulation step presenting highest removals of CAF. The activated carbon filtration showed removal efficiency under 10%, whereas the disinfection step presented low efficiency to remove CAF. At São José do Rio Preto city were found, at least once, BPA, E1, E3, PhPh, CAF, TCS, and ATZ in surface water; BPA, TCS, and CAF in groundwater, and BPA, CAF, and ATZ in drinking water / Doutorado / Quimica Analitica / Doutor em Ciências
18

Tratamento e recuperação da água de lavagem dos filtros de uma estação de filtração direta e simulação da disposição dos lodos em estações de tratamento de esgoto / Treatment and recovery of wastes from backwash filter on direct filter water treatment systems and simulation of sludge disposal in wastewater treatment systems

Escobar Rivera, Juan Carlos 16 February 2001 (has links)
Foi pesquisada a aplicação de métodos, em nível de laboratório, através dos quais é possível otimizar, tratar e dispor resíduos de lavagem de filtros de estações de tratamento de água (Caso ETA do rio Descoberto - ETA-RD Brasília). Na clarificação da água de lavagem dos filtros, observou-se o efeito favorável da adição de polímero para melhorar a separação líquido-sólido é, portanto, as eficiências de remoção de turbidez, cor aparente, sólidos suspensos e coliformes totais. Observou-se melhor sedimentabilidade do lodo a ser desaguado. Os ensaios de centrifugação, em escala de bancada, mostraram que o método aplicado auxilia na determinação da dosagem a ser usada numa centrífuga em escala real. Foram avaliados três métodos de disposição do lodo adensado da ETA-RD em ETE: 1) sedimentação com esgoto sanitário e posterior digestão anaeróbia do lodo; 2) Digestão anaeróbia e 3) digestão aeróbia. Os melhores resultados foram obtidos com a digestão anaeróbia. Os estudos realizados mostraram que há diversas alternativas de tratamento e disposição desses resíduos, mas é necessário, sempre que possível, a avaliação das diferentes alternativas para selecionar a(s) mais apropriada(s) a cada caso em particular, pois fatores como custos e disponibilidade de de sistemas ou equipamentos, definirão a aplicabilidade ou não de determinado método. / It was researched the application of methods on laboratory bench scale to optimize the reuse, treatment and disposal of wastes from filter backwash of Water Treatment Plant - WTP (WTP-RD Descoberto River, Brasília case). In the clarification process of this waste, favorable effect of addition of polymer for best liquid-solid separation and, thus, better removal efficiencies of turbidity, apparent color, suspended solids and total coliforms was observed. Better sedimentability of the sludge occurred. The centrifugation tests showed that the applied method help on determination of dosagem to be used in full scale. Three methods to dispose thickened sludge of WTP-RD on wastewater treatment Plants - WWTP were evaluated: 1) Sedimentation with domestic sewage and anaerobic digestion of sludge; 2) Anaerobic digestion and 3) Aerobic digestion. Best results were obtained with anaerobic digestion. The results showed that there are alternatives of treatment and disposal of wastes of WTP, but is necessary, if possible, to make the evaluation of this alternatives to select the most appropriate(s) in each case because factors as costs, systems or equipments availability, will define the applicability or not of a particular method.
19

Tratamento e recuperação da água de lavagem dos filtros de uma estação de filtração direta e simulação da disposição dos lodos em estações de tratamento de esgoto / Treatment and recovery of wastes from backwash filter on direct filter water treatment systems and simulation of sludge disposal in wastewater treatment systems

Juan Carlos Escobar Rivera 16 February 2001 (has links)
Foi pesquisada a aplicação de métodos, em nível de laboratório, através dos quais é possível otimizar, tratar e dispor resíduos de lavagem de filtros de estações de tratamento de água (Caso ETA do rio Descoberto - ETA-RD Brasília). Na clarificação da água de lavagem dos filtros, observou-se o efeito favorável da adição de polímero para melhorar a separação líquido-sólido é, portanto, as eficiências de remoção de turbidez, cor aparente, sólidos suspensos e coliformes totais. Observou-se melhor sedimentabilidade do lodo a ser desaguado. Os ensaios de centrifugação, em escala de bancada, mostraram que o método aplicado auxilia na determinação da dosagem a ser usada numa centrífuga em escala real. Foram avaliados três métodos de disposição do lodo adensado da ETA-RD em ETE: 1) sedimentação com esgoto sanitário e posterior digestão anaeróbia do lodo; 2) Digestão anaeróbia e 3) digestão aeróbia. Os melhores resultados foram obtidos com a digestão anaeróbia. Os estudos realizados mostraram que há diversas alternativas de tratamento e disposição desses resíduos, mas é necessário, sempre que possível, a avaliação das diferentes alternativas para selecionar a(s) mais apropriada(s) a cada caso em particular, pois fatores como custos e disponibilidade de de sistemas ou equipamentos, definirão a aplicabilidade ou não de determinado método. / It was researched the application of methods on laboratory bench scale to optimize the reuse, treatment and disposal of wastes from filter backwash of Water Treatment Plant - WTP (WTP-RD Descoberto River, Brasília case). In the clarification process of this waste, favorable effect of addition of polymer for best liquid-solid separation and, thus, better removal efficiencies of turbidity, apparent color, suspended solids and total coliforms was observed. Better sedimentability of the sludge occurred. The centrifugation tests showed that the applied method help on determination of dosagem to be used in full scale. Three methods to dispose thickened sludge of WTP-RD on wastewater treatment Plants - WWTP were evaluated: 1) Sedimentation with domestic sewage and anaerobic digestion of sludge; 2) Anaerobic digestion and 3) Aerobic digestion. Best results were obtained with anaerobic digestion. The results showed that there are alternatives of treatment and disposal of wastes of WTP, but is necessary, if possible, to make the evaluation of this alternatives to select the most appropriate(s) in each case because factors as costs, systems or equipments availability, will define the applicability or not of a particular method.
20

Estudo da reciclagem de lodo de eta na fabricação de agregado sintético em mistura com cinza volante de carvão mineral / Study of recycling sludge eta in manufacturing synthetic aggregate mixture with coal ash wheel

SILVA, Elzelis Muller da 22 November 2016 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-06-29T17:44:14Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstudoReciclagemLodo.pdf: 5341641 bytes, checksum: d0cce096412ee3071d00573a065374d8 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-07-07T13:12:04Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstudoReciclagemLodo.pdf: 5341641 bytes, checksum: d0cce096412ee3071d00573a065374d8 (MD5) / Made available in DSpace on 2017-07-07T13:12:04Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstudoReciclagemLodo.pdf: 5341641 bytes, checksum: d0cce096412ee3071d00573a065374d8 (MD5) Previous issue date: 2016-11-22 / UEPA - Universidade do Estado do Pará / Os resíduos (lodo) gerados nas Estações de Tratamento de Água (ETA) e as cinzas volantes provenientes da queima de carvão mineral em usinas termelétricas causam problemas pela quantidade e concentração de substâncias nocivas presentes nos mesmos. Dessa forma, este trabalho visou produzir agregados sintéticos utilizando lodo da ETA Bolonha (Belém/PA) e cinza volante avaliando sua viabilidade técnica e ambiental. A composição dos agregados sintéticos consistiu de uma elevada concentração desses resíduos em mistura com argila para a moldagem e sinterização às temperaturas de 1200 °C e 1250 °C. Foram realizadas análises físicas, mineralógicas e microestrutural dos agregados sintéticos. Dois concretos foram produzidos, um com agregado sintético, e outro referência. Nos concretos foram avaliadas as suas propriedades físicas e mecânicas no estado fresco e endurecido, e suas microestruturas. Para a caracterização dos resíduos dos concretos foram realizados ensaios de lixiviação e solubilização. Os agregados sintéticos foram classificados como agregados leves por apresentarem baixa massa especifica (< 2,0 g/cm3) de acordo com a NBR 7211 (ABNT, 2009). O concreto produzido com agregado sinterizado (AGS-02) à 1250 °C foi classificado como concreto leve não estrutural segundo as normas NBR 6118 (ABNT, 2014) e NBR 8953 (ABNT, 2015). Os resíduos dos concretos foram classificados como resíduos classe IIB, não perigoso e inerte pela NBR 10004 (ABNT, 2004) e dentro dos limites das Resoluções n° 20/1986 e 430/2011 do CONAMA, para os rios classe 2. Destaca-se que o agregado sintético atende as demandas da indústria da construção civil, reduz o consumo de matérias-primas e oferece uma alternativa à disposição final dos resíduos. / The Wastes (sludge) generated in the Water Treatment Plants (WTP) and fly ash from coal-fired power plants cause problems by the amount and concentration of harmful substances in them. Thus, this study aimed to produce synthetic aggregates using sludge WTP Bolonha (Belém/PA) and fly ash assessing their technical and environmental viability. The composition of the synthetic aggregates consisted of a high concentration of these residues in mixture with clay to molding and sintering at temperatures of 1200°C and 1250°C. The physical, mineralogical and microstructural analyzes of the synthetic aggregate were performed. Two concrete were produced, one with synthetic aggregate, and other references. In concrete were assessed their physical and mechanical properties in fresh and hardened state, and their microstructures. For the characterization of the concrete waste leaching and dissolution testing were performed. Synthetic aggregates were classified as lightweight aggregate for its low bulk density (<2.0 g / cm3) according to NBR 7211 (ABNT, 2009). The concrete produced with sintered aggregate (AGS-02) at 1250 °C was classified as non structural lightweight concrete according to the norms NBR 6118 (ABNT, 2014) and NBR 8953 (ABNT, 2015). The concrete of waste were classified as waste class IIB, non-hazardous and inert by NBR 10004 (ABNT, 2004) and within the limits of Resolutions No. 20/1986 and 430/2011 CONAMA into rivers class 2. It is noteworthy the synthetic aggregate meets the demands of the construction industry, reduces the consumption of raw materials and offers an alternative to the final disposal of waste.

Page generated in 0.1522 seconds