• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • Tagged with
  • 38
  • 38
  • 37
  • 37
  • 13
  • 13
  • 12
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Influência dos cimentos resinosos e sistemas cerâmicos na translucidez e estabilidade de cor de restaurações laminadas / Influence of resin cements luting and ceramic systems in the translucency and color stability of veneers

Silami, Francisca Daniele Jardilino 31 March 2017 (has links)
O objetivo desse estudo foi avaliar o grau de conversão, a estabilidade de cor e translucidez de cimentos resinosos para cimentação de laminados cerâmicos em duas espessuras, submetidos a diferentes protocolos de envelhecimento. Foram utilizados 270 incisivos bovinos hígidos, cujas porções radiculares foram cortadas e as porções coronárias foram incluídas em matriz de PVC (25mm de diâmetro) com resina acrílica. As faces vestibulares foram planificadas até a dentina. Foram confeccionados 240 corpos-de-prova em cerâmica prensada (IPS e-max Press e IPS e- maxZirpress, IvoclarVivadent), em duas espessuras (0,5 mm e 1,0 mm), que foram separados aleatoriamente em dois grupos, segundo o tipo de cimento resinoso utilizado para fixação: fotoativado (Variolink II, Ivoclar/Vivadent) ou dual (Rely U 200, 3M ESPE). Após a cimentação, todas as amostras foram mantidas em estufa a 37°C por 24h, após o qual foram realizadas as leituras de cor e translucidez iniciais (Vita EasyShade, VITA). Em seguida, as amostras foram subdivididas em três grupos (n=10) de acordo com o envelhecimento a que foram submetidos: Controle sem envelhecimento; imersão em água destilada por 1 ano e fadiga termomecânica (1.200.000 ciclos, frequência de1,3Hz e ciclagem térmica de 5°C/37°C/55°C). Como controle, foram obtidos 30 corpos-de-prova de cada cimento resinoso (0,5mm) e 30 dentes foram planificados e submetidos aos mesmos processos de envelhecimento, após o qual leituras finais foram realizadas. Foram analisados também o grau de conversão dos cimentos polimerizados através das restaurações (FTIR) e a linha de cimentação em cada um dos grupos (n=3), antes e depois do envelhecimento. Para isso, as amostras, selecionadas aleatoriamente, foram seccionadas no sentido longitudinal e analisadas em estereomicroscópio de dupla coordenada (Nikon Measurescope). Os dados de estabilidade de cor (&Delta;E), translucidez, grau de conversão e linha de cimentação foram submetidas à análise estatística (3-way ANOVA, Tukey, p<0,05). O cimento autoadesivo apresentou maior grau de conversão que o fotoativado (p<0,05) quando utilizada a cerâmica Zirpress, mas produziu maior alteração de cor (p<0,05) e menor translucidez nas restaurações de E-maxPress de 0,5mm. A ciclagem termomecânica não foi significante para alterações óticas dos sistemas cerâmicos testados. Conclui-se que a espessura do laminado cerâmico não altera o grau de conversão dos cimentos resinosos e o tipo de cimento resinoso influencia a estabilidade de cor das restaurações cerâmicas quando submetido ao envelhecimento com água destilada. / The aim of this study is to evaluate the degree of conversion, color stability and translucency of resin cement for luting ceramic veneers with two thicknesses submitted to different aging protocols. Two hundred and seventy bovine incisors were used, which had the root cut, and the coronal were embedded in acrylic resin into PVC rings (25mm diameter). The buccal surface was flattened until dentin. Two hundred and forty pressed ceramic veneers (IPS e-max Press and IPS e-max ZirPress, IvoclarVivadent) were obtained, in two thicknesses (0,5 mm and 1.0 mm), that were randomly separated into two groups according to the type of resin cement used for luting: light-cured (Variolink II, Ivoclar / Vivadent) or dual cured (Rely U 200, 3M ESPE). After the cementation, all samples were maintained at 37 °C for 24 h; after first color and translucency readings (Vita EasyShade, VITA) were made. The samples were separated into 3 groups (n=10) according to the aging that was submitted: control without aging, immersion in distilled water for one year and thermomechanical cycling (1.200.000 cycles, frequency of 1,3Hz and thermal cycling of 5°C/37°C/55°C). As the control group, 30 samples of each resin cement (0,5 mm) and flattened teeth were obtained and submitted to the same aging protocols. After tests, the final color and translucency readings were taken. The degree of conversion of resin cements through veneer restoration, and the cement film thickness (n=3) for each group were analyzed (FTIR), before and after aging. For this, the samples were randomly selected, sectioned longitudinally and examined by a stereomicroscope (Nikon Measurescope). The results of color stability (&Delta;E), translucency, degree of conversion and cement film thicknesses were statistically analyzed (3-way, ANOVA, Tukey, p<0.05). The self-adhesive cement showed the higher degree of conversion than light-activated luting cement (p<0.05) when Zirpress ceramic was used, but produced higher color change (p<0.05) and lower translucency in 0.5mm E-maxPress restorations. The thermomechanical cycling was not significant for optical changes of tested ceramic systems. It was concluded that the thickness of ceramic veneers didnt alter the degree of conversion of resin cement and the type of resin cement has influenced the color stability of ceramic restorations when submitted to water aging.
32

Análise das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos à ação do calor e do frio para fins periciais / Analysis of physical and mechanical properties of dental restorative materials subjected to the action of heat and cold for forensic purposes

Biancalana, Roberto Cesar 03 June 2015 (has links)
O objetivo deste trabalho foi avaliar o efeito da ação do calor e do frio sobre a estabilidade de cor, rugosidade de superfície e microdureza de restaurações de resina composta (FiltekMR Z250 XT 3M ESPE®), cimento de ionômero de vidro (KetacTM Fil Plus 3M ESPE®) e amálgama de prata em cápsulas (gs-80 SDI®), na tentativa de simular o comportamento desses materiais, quando presentes nos elementos dentais de vítimas carbonizadas ou mortas por congelamento. Foram selecionados 180 dentes bovinos que foram preparados (6 X 6 mm com 2 mm de profundidade) e separados em grupos de 30 dentes, segundo o tipo de material restaurador utilizado. Em seguida, foram realizadas as leituras iniciais de cor (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (Microdurômetro Shimadzu® Micro Hardness Tester HMV-2), que foram consideradas os padrões iniciais. Subsequentemente, os dentes foram separados aleatoriamente em grupos (n=10) segundo a temperatura utilizada para simulação de congelamento (-80°C), (-20°C) e 2,5°C; e carbonização (100°C, 200°C e 300°C). A submissão a altas temperaturas foi realizada pela colocação dos dentes restaurados em forno (ALUMINI Sinter-Press EDG®), pelo período de 15 minutos, e as baixas temperaturas foram realizadas em refrigerador (RFGE 700 GE®) a 2,5°C; congelador (CVU18 Consul®) a (-20°C) e freezer (Ultra Freezer AL 374 - 80V American Lab®) a (-80°C). Após 7 e 30 dias de ação do frio e da submissão ao calor, os dentes foram submetidos às leituras finais de cor, rugosidade e microdureza. No calor, os valores de alteração de cor (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*), dos dois materiais estéticos, rugosidade superficial e microdureza dos três materiais restauradores, foram submetidos à análise estatística One-way ANOVA, Tukey (p<0,05), tendo como fator de variação, a temperatura. No frio, os dados foram submetidos à análise estatística 2-way ANOVA, Bonferroni (p<0,05), tendo como fatores de variação, o tempo e a temperatura. Verificou-se que houve alteração de cor dos materiais estéticos, tanto nas submissões ao calor quanto ao frio. Na resina composta, a rugosidade de superfície e a microdureza não se alteraram significantemente (p>0,05), independente da temperatura a que foram submetidos. No CIV, a rugosidade e a microdureza elevaram-se nos testes ao calor; e ao frio, não ocorreram alterações significativas (p>0,05) dessas propriedades. Para o amálgama houve alteração de rugosidade significante (p<0,05) no calor, nas submissões a 300°C; e a microdureza não se modificou. Ao frio não ocorreram mudanças significantes (p>0,05) na rugosidade nem na microdureza do amálgama. Concluiu-se que os materiais estéticos podem ser distinguidos, pela análise de cor, a partir de 200°C até 300°C e quando submetidos a (-80°C), tanto em 7 dias como em 30 dias. O tempo de congelamento não é significativo para a distinção dos materiais. Testes de rugosidade e microdureza podem distinguir os materiais estéticos, independentemente, da ação do calor ou do frio. / The purpose of this study was to evaluate the effect of the action of heat and cold on color stability, surface roughness and microhardness of composite resin (FiltekMR Z250 XT 3M ESPE®), glass ionomer cement (KetacTM Fil Plus 3M ESPE®) and silver amalgam capsules (gs-80 SDI®) restorations, in an attempt to simulate the behavior of these materials when present in dental elements of carbonized or killed by freezing victims. 180 bovine teeth were selected, prepared with a 6 x 6 mm 2 mm cavity and then separated into groups of 30 teeth, according to the type of restorative material. Then, initial color readings (Spectrophotometer VITA® Easyshade), surface roughness (Rugosimeter Mitutoyo® Surftest SJ-201P) and Knoop microhardness (Shimadzu Micro Hardness tester® HMV-2) readings were performed, which were considered the initial standards. Afterwards, the teeth were randomly divided into groups (n=10) according to the temperature used for freezing simulation (-80°C), (-20°C), (2,5°C); and carbonization simulation (100°C, 200°C, 300°C). Submission to high temperatures was performed by placing the restored teeth in an oven (ALUMINI Sinter Press EDG®), for 15 minutes and for low temperatures, a refrigerator (RFGE 700 GE®) at 2,5°C, a freezer (CVU18 Consul®) at (-20°C) and an ultra freezer (Ultra Freezer AL 374 - 80V American Lab®) at (-80°C) were used. After the teeth being submitted to the action of cold and heat for 7 and 30 days, the color, surface roughness and microhardness final readings were performed. For the heat evaluation, the color change (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*) of the two aesthetic materials, and the surface roughness and microhardness of the three restorative materials, were subjected to statistical analysis (One-way ANOVA, Tukey, p<.05), with one variation factor, the temperature. For the cold evaluation, the data were statistically analyzed using 2-way ANOVA, Bonferroni, (p>.05) with two variation factors, time and temperature. Color alteration occurred for the aesthetic materials submitted to heat and cold. In the composite resin, the surface roughness and microhardness did not change (p>.05), regardless of temperature to which they were exposed. In CIV, the surface roughness and microhardness increased with the heat. After cold submission, there were no significant changes (p>.05) to these properties. For the amalgam, there was roughness change (p<.05) when submitted to heat at 300°C; the microhardness did not change. There were no significant changes in amalgam roughness or microhardness when teeth were submitted to cold (p>.05). It was concluded that the aesthetic materials can be distinguished by the color analysis, from 200°C to 300°C and when submitted to (-80°C), both after 7 days and 30 days. The freezing time is not significant for the distinction of materials. Roughness and microhardness tests can distinguish the aesthetic materials, regardless of the action of heat or cold.
33

Resistência à flexão, sorção, solubilidade e estabilidade de cor de compósitos odontológicos reforçados por fibras / Flexural strength, water sorption, solubility and color stability of some fiber reinforced composite

Medeiros, Renata Souza 10 August 2012 (has links)
Os objetivos deste estudo foram: 1) avaliar a resistência à flexão em três pontos de um compósito para uso direto (Filtek Z350 XT, 3M ESPE) e um para uso indireto (Signum, Heraeus, Kulzer) reforçados por uma ou duas camadas de fibras de polietileno (Ribbond -THM, Ribbond®) ou de vidro (Interlig, Ângelus) tratados termicamente (170°C por 10 minutos), comparados com os grupos controle (não reforçados por fibras e/ou não tratados termicamente; 2) avaliar a sorção, a solubilidade e a estabilidade de cor dos compósitos reforçados, após armazenamento em água destilada à 37°C por 14 dias. A estabilidade de cor foi avaliada com auxílio de um espectrofotômetro de contato dental (Vita EasyShade, Vident, CA, USA). Para o ensaio de resistência à flexão, foram confeccionados espécimes retangulares com dimensões de 12 x 2 x 2mm (n=10), com os seguintes fatores de variação: a) compósito (para uso direto ou indireto); b) tipo e número de camadas de fibras (vidro ou polietileno/uma ou duas camadas); c) submetidos ou não a tratamento térmico. O tratamento térmico foi realizado 24 horas após fotoativação em estufa à temperatura de 170°C por 10 minutos. O ensaio foi realizado 24 horas após fotoativação ou tratamento térmico. Para avaliação de sorção/solubilidade e estabilidade de cor, foram confeccionados espécimes em forma de disco com dimensões de 15 x 2mm (n=5), em que foram analisados os seguinte fatores: a) compósito (para uso direto ou indireto); b) tipo de fibra (vidro ou polietileno); c) número de camadas de fibras (uma ou duas). Foi realizada análise dos parâmetros de cor antes e após imersão em água deionizada por 14 dias. Os resultados foram analisados por ANOVA e teste de contraste de Tukey, com nível de significância de 5% e revelaram que a fibra de vidro, quando utilizada em duas camadas, propiciou os maiores valores de resistência à flexão para os dois compósitos testados (165,4 MPa Z350XT e 208,7MPa Signum ). O tratamento térmico não apresentou significância estatística quanto à resistência à flexão do compósito direto. Para o compósito para uso indireto (Signum ) foi encontrada diferença estatisticamente significante para o fator tratamento térmico, que indicou valores de resistência à flexão inferiores para os grupos tratados termicamente. O compósito para uso direto apresentou valor de sorção superior (33,6/cm3) ao do compósito para uso indireto (19,1/cm3). Para solubilidade, foi encontrada interação para os fatores compósito e tipo de fibra, indicando maiores valores para o compósito para uso direto associado à fibra de vidro. A análise de alteração de cor demonstrou maior valor de E para a fibra de polietileno (E =1,5) quando comparado à fibra de vidro (E=1,0). Concluiu-se que: 1) a adição de fibras propicia aumento dos valores de resistência à flexão de compósitos para uso direto e indireto, o aumento da resistência foi observado quando do uso de duas camadas de fibras; 2) o tratamento térmico à 170°C por 10 minutos não indicou melhora nas propriedades mecânicas dos compósitos reforçados; 3) adicionar fibras aos compósitos não aumentou os valores de sorção/solubilidade quando imersos em água; 4) Imersão em água não produziu alterações de cor relevantes para os compósitos reforçados com fibras se comparados aos sem fibras. / The aims of this study were: 1) to evaluate the flexural strength of one composite for direct use (Filtek Z350 XT, 3M ESPE) and one for indirect use (Signum, Heraeus, Kulzer) as a function of the reinforcement by one or two layers of polyethylene (THM-Ribbond, Ribbond ®) or glass fibers (Interlig, Angelus) submitted to heat treatment (170°C for 10 minutes) compared with control groups (not reinforced by fibers and/or not heat-treated; 2) evaluate water sorption, solubility and color stability of the reinforced composites, after storage in distilled water at 37°C for 14 days. Color stability was evaluated using a spectrophotometer (Vita Easyshade, Vident, CA, USA). For three point flexural bending test, rectangular specimens were prepared with dimensions of 12 x 2 x 2 mm (n=10), according to the following variation factors: a) composite (for direct or indirect use); b) type of fibers and number of layers (glass or polyethylene/one or two layers; c) subjected or not to heat treatment. The heat treatment was performed 24 hours after curing, in a furnace, at 170 ° C for 10 minutes. Tests were performed 24 hours after curing or heat treatment. To evaluate the water sorption/solubility and color stability, disc-shaped specimens were prepared with dimensions of 15 x 2 mm (n=5) according to the following variation factors: a) composite (for direct or indirect uses); b) fiber type (glass or polyethylene); c) number of fiber layers (one or two). Color parameters were analyze before and after immersion in deionized water for 14 days. The results were analyzed by ANOVA and Tukeys test with significance level of 5%, and indicated that the glass fiber when used in two layers, showed the highest flexural strength for the two tested composites (165.4 MPa - Z350XT and 208.7 MPa - Signum ). The heat treatment did not significantly affect the flexural strength of the direct composite. For the composite for indirect use (Signum ), a statistical significance for the factor heat treatment was found, indicating lower values of flexural strength for heat-treated groups. The composite for direct use showed higher water sorption value (33.6 /cm3) when compared to the composite for indirect use (19.1 /cm3). For solubility, a significant interaction was found for composite and fiber type, indicating higher values for direct composite and glass fiber. Color stability analysis showed higher color difference value for polyethylene fiber (E =1.5) when compared to glass fiber (E=1.0). It was concluded that: a) adding fibers increased the flexural strength values of the composites for direct or indirect use, the increase in strength was more pronounced when using two fiber layers; 2) heat treatment at 170 ° C for 10 minutes showed no improvement of the mechanical properties of fiber reinforced composites; 3) adding fibers to the composite did not increase the sorption/solubility after water immersion, 4) Immersion in water did not change the color of the fiber reinforced composites when compared with those without fibers.
34

Influência dos cimentos resinosos e sistemas cerâmicos na translucidez e estabilidade de cor de restaurações laminadas / Influence of resin cements luting and ceramic systems in the translucency and color stability of veneers

Francisca Daniele Jardilino Silami 31 March 2017 (has links)
O objetivo desse estudo foi avaliar o grau de conversão, a estabilidade de cor e translucidez de cimentos resinosos para cimentação de laminados cerâmicos em duas espessuras, submetidos a diferentes protocolos de envelhecimento. Foram utilizados 270 incisivos bovinos hígidos, cujas porções radiculares foram cortadas e as porções coronárias foram incluídas em matriz de PVC (25mm de diâmetro) com resina acrílica. As faces vestibulares foram planificadas até a dentina. Foram confeccionados 240 corpos-de-prova em cerâmica prensada (IPS e-max Press e IPS e- maxZirpress, IvoclarVivadent), em duas espessuras (0,5 mm e 1,0 mm), que foram separados aleatoriamente em dois grupos, segundo o tipo de cimento resinoso utilizado para fixação: fotoativado (Variolink II, Ivoclar/Vivadent) ou dual (Rely U 200, 3M ESPE). Após a cimentação, todas as amostras foram mantidas em estufa a 37°C por 24h, após o qual foram realizadas as leituras de cor e translucidez iniciais (Vita EasyShade, VITA). Em seguida, as amostras foram subdivididas em três grupos (n=10) de acordo com o envelhecimento a que foram submetidos: Controle sem envelhecimento; imersão em água destilada por 1 ano e fadiga termomecânica (1.200.000 ciclos, frequência de1,3Hz e ciclagem térmica de 5°C/37°C/55°C). Como controle, foram obtidos 30 corpos-de-prova de cada cimento resinoso (0,5mm) e 30 dentes foram planificados e submetidos aos mesmos processos de envelhecimento, após o qual leituras finais foram realizadas. Foram analisados também o grau de conversão dos cimentos polimerizados através das restaurações (FTIR) e a linha de cimentação em cada um dos grupos (n=3), antes e depois do envelhecimento. Para isso, as amostras, selecionadas aleatoriamente, foram seccionadas no sentido longitudinal e analisadas em estereomicroscópio de dupla coordenada (Nikon Measurescope). Os dados de estabilidade de cor (&Delta;E), translucidez, grau de conversão e linha de cimentação foram submetidas à análise estatística (3-way ANOVA, Tukey, p<0,05). O cimento autoadesivo apresentou maior grau de conversão que o fotoativado (p<0,05) quando utilizada a cerâmica Zirpress, mas produziu maior alteração de cor (p<0,05) e menor translucidez nas restaurações de E-maxPress de 0,5mm. A ciclagem termomecânica não foi significante para alterações óticas dos sistemas cerâmicos testados. Conclui-se que a espessura do laminado cerâmico não altera o grau de conversão dos cimentos resinosos e o tipo de cimento resinoso influencia a estabilidade de cor das restaurações cerâmicas quando submetido ao envelhecimento com água destilada. / The aim of this study is to evaluate the degree of conversion, color stability and translucency of resin cement for luting ceramic veneers with two thicknesses submitted to different aging protocols. Two hundred and seventy bovine incisors were used, which had the root cut, and the coronal were embedded in acrylic resin into PVC rings (25mm diameter). The buccal surface was flattened until dentin. Two hundred and forty pressed ceramic veneers (IPS e-max Press and IPS e-max ZirPress, IvoclarVivadent) were obtained, in two thicknesses (0,5 mm and 1.0 mm), that were randomly separated into two groups according to the type of resin cement used for luting: light-cured (Variolink II, Ivoclar / Vivadent) or dual cured (Rely U 200, 3M ESPE). After the cementation, all samples were maintained at 37 °C for 24 h; after first color and translucency readings (Vita EasyShade, VITA) were made. The samples were separated into 3 groups (n=10) according to the aging that was submitted: control without aging, immersion in distilled water for one year and thermomechanical cycling (1.200.000 cycles, frequency of 1,3Hz and thermal cycling of 5°C/37°C/55°C). As the control group, 30 samples of each resin cement (0,5 mm) and flattened teeth were obtained and submitted to the same aging protocols. After tests, the final color and translucency readings were taken. The degree of conversion of resin cements through veneer restoration, and the cement film thickness (n=3) for each group were analyzed (FTIR), before and after aging. For this, the samples were randomly selected, sectioned longitudinally and examined by a stereomicroscope (Nikon Measurescope). The results of color stability (&Delta;E), translucency, degree of conversion and cement film thicknesses were statistically analyzed (3-way, ANOVA, Tukey, p<0.05). The self-adhesive cement showed the higher degree of conversion than light-activated luting cement (p<0.05) when Zirpress ceramic was used, but produced higher color change (p<0.05) and lower translucency in 0.5mm E-maxPress restorations. The thermomechanical cycling was not significant for optical changes of tested ceramic systems. It was concluded that the thickness of ceramic veneers didnt alter the degree of conversion of resin cement and the type of resin cement has influenced the color stability of ceramic restorations when submitted to water aging.
35

Estudo das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos a condições de inumação e afogamento para fins periciais / Study of physical and mechanical properties of dental restorative materials subjected to conditions of inhumation and drowning for forensic purposes

Vicente, Sergio Augusto de Freitas 12 January 2015 (has links)
O objetivo deste estudo foi avaliar o efeito da simulação de condições de inumação e afogamento sobre estabilidade de cor, rugosidade de superfície e microdureza de resina composta (RC), cimento de ionômero de vidro (CIV) e amálgama de prata (AM), visando fornecer elementos para diferenciação de materiais estéticos e estimativa do tempo de submissão aos agentes. Foram obtidos 60 incisivos bovinos, que receberam preparos cavitários (6 x 6 mm e 2 mm de profundidade) e foram restaurados com RC FiltekMR Z250 XT (3M ESPE®), CIV KetacTM Fil Plus (3M ESPE®) e AM em cápsulas gs-80 (SDI®). Realizaram-se as primeiras leituras, que se constituíram no baseline, de: cor, (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (microdurômetro Shimadzu® Micro Hardness Tester HMV-2). Em seguida, as amostras foram separadas em dois grupos de 30 (n=10), de acordo com as condições a que foram submetidas: simulação de condições de inumação e de afogamento, por 1, 3 e 6 meses, após os quais novas leituras foram realizadas. Os valores de alteração de cor (&Delta;E, &Delta;L, &Delta;a e &Delta;b) e demais propriedades dos materiais estéticos foram submetidos a análise estatística 3-way ANOVA, medidas repetidas, Bonferroni (p<0,05). Para o amálgama, foram comparados rugosidade superficial e microdureza (2-way ANOVA, medidas repetidas, Bonferroni, p<0,05). Verificou-se que condições de inumação e de afogamento produzem alteração de cor nos materiais restauradores estéticos, que não é tempo dependente. Não houve diferença (p>0,05) na microdureza dos materiais restauradores estéticos em função dos agentes e tempos testados, apesar de apresentarem diferenças inerentes quanto a essa propriedade. Houve alteração significativa (p<0,05) na microdureza do AM, após 6 meses de afogamento. Quanto à rugosidade de superfície, não houve diferença significante (p>0,05) para nenhum dos materiais, agentes e tempos testados. Concluiu-se que a contribuição desses métodos à identificação humana após inumação ou afogamento só é possível considerando-se a microdureza, sendo auxiliada pela análise da alteração de cor do material. Não é possível predizer o tempo de inumação ou afogamento de um indivíduo apenas com base nos parâmetros estudados / The purpose of this study was to evaluate the effect of simulated drowning and burial conditions on color stability, surface roughness and microhardness of composite resin (RC), glass ionomer cement (CIV) and silver amalgam (AM), aiming to provide elements for differentiation of aesthetic materials and estimation of the time of the agents have been subjected to these conditions. 60 bovine incisors were prepared with a 6 x 6 x 2mm cavity and were restored with RC FiltekMR XT Z250 (3M ESPE®), CIV KetacTM Fil (3M ESPE®) and AM capsules gs-80 (SDI®). The color, surface roughness and microhardness baselines were measured using a reflectance spectrophotometer with CIE L*a*b* system (VITA® Easyshade), a surface roughness device (Mitutoyo® Surftest SJ-201P) and a micro hardness tester (Shimadzu® HMV-2). Then, the samples were separated into two groups of 30 (n=10), in accordance with the conditions that they were subjected: simulation of burial and drowning conditions, for 1, 3 and 6 months, after which further measurements were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b and the other properties of the aesthetic materials were statistically analyzed using 3-way ANOVA, repeated measures, Bonferroni (p<.05). For the amalgam, only surface roughness and microhardness were compared (2-way ANOVA, repeated measures, Bonferroni, p<.05). It was found that burial and drowning conditions produce color change in the aesthetic restorative materials, which is not time dependent. There was no difference (p>.05) in microhardness of aesthetic restorative materials caused by the agents and times tested, notwithstanding they have inherent differences regarding this property. There was significant change (p<.05) in AM microhardness after 6 months of drowning. Regarding surface roughness, there was no significant difference (p>.05) for any material, agents and times tested. It was concluded that the contribution of these methods to human identification after burial or drowning is only possible considering the hardness, being aided by the analysis of the color change of the material. It is not possible to predict the time of burial or drowning of an individual based solely on the studied parameters
36

Estudo das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos a condições de inumação e afogamento para fins periciais / Study of physical and mechanical properties of dental restorative materials subjected to conditions of inhumation and drowning for forensic purposes

Sergio Augusto de Freitas Vicente 12 January 2015 (has links)
O objetivo deste estudo foi avaliar o efeito da simulação de condições de inumação e afogamento sobre estabilidade de cor, rugosidade de superfície e microdureza de resina composta (RC), cimento de ionômero de vidro (CIV) e amálgama de prata (AM), visando fornecer elementos para diferenciação de materiais estéticos e estimativa do tempo de submissão aos agentes. Foram obtidos 60 incisivos bovinos, que receberam preparos cavitários (6 x 6 mm e 2 mm de profundidade) e foram restaurados com RC FiltekMR Z250 XT (3M ESPE®), CIV KetacTM Fil Plus (3M ESPE®) e AM em cápsulas gs-80 (SDI®). Realizaram-se as primeiras leituras, que se constituíram no baseline, de: cor, (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (microdurômetro Shimadzu® Micro Hardness Tester HMV-2). Em seguida, as amostras foram separadas em dois grupos de 30 (n=10), de acordo com as condições a que foram submetidas: simulação de condições de inumação e de afogamento, por 1, 3 e 6 meses, após os quais novas leituras foram realizadas. Os valores de alteração de cor (&Delta;E, &Delta;L, &Delta;a e &Delta;b) e demais propriedades dos materiais estéticos foram submetidos a análise estatística 3-way ANOVA, medidas repetidas, Bonferroni (p<0,05). Para o amálgama, foram comparados rugosidade superficial e microdureza (2-way ANOVA, medidas repetidas, Bonferroni, p<0,05). Verificou-se que condições de inumação e de afogamento produzem alteração de cor nos materiais restauradores estéticos, que não é tempo dependente. Não houve diferença (p>0,05) na microdureza dos materiais restauradores estéticos em função dos agentes e tempos testados, apesar de apresentarem diferenças inerentes quanto a essa propriedade. Houve alteração significativa (p<0,05) na microdureza do AM, após 6 meses de afogamento. Quanto à rugosidade de superfície, não houve diferença significante (p>0,05) para nenhum dos materiais, agentes e tempos testados. Concluiu-se que a contribuição desses métodos à identificação humana após inumação ou afogamento só é possível considerando-se a microdureza, sendo auxiliada pela análise da alteração de cor do material. Não é possível predizer o tempo de inumação ou afogamento de um indivíduo apenas com base nos parâmetros estudados / The purpose of this study was to evaluate the effect of simulated drowning and burial conditions on color stability, surface roughness and microhardness of composite resin (RC), glass ionomer cement (CIV) and silver amalgam (AM), aiming to provide elements for differentiation of aesthetic materials and estimation of the time of the agents have been subjected to these conditions. 60 bovine incisors were prepared with a 6 x 6 x 2mm cavity and were restored with RC FiltekMR XT Z250 (3M ESPE®), CIV KetacTM Fil (3M ESPE®) and AM capsules gs-80 (SDI®). The color, surface roughness and microhardness baselines were measured using a reflectance spectrophotometer with CIE L*a*b* system (VITA® Easyshade), a surface roughness device (Mitutoyo® Surftest SJ-201P) and a micro hardness tester (Shimadzu® HMV-2). Then, the samples were separated into two groups of 30 (n=10), in accordance with the conditions that they were subjected: simulation of burial and drowning conditions, for 1, 3 and 6 months, after which further measurements were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b and the other properties of the aesthetic materials were statistically analyzed using 3-way ANOVA, repeated measures, Bonferroni (p<.05). For the amalgam, only surface roughness and microhardness were compared (2-way ANOVA, repeated measures, Bonferroni, p<.05). It was found that burial and drowning conditions produce color change in the aesthetic restorative materials, which is not time dependent. There was no difference (p>.05) in microhardness of aesthetic restorative materials caused by the agents and times tested, notwithstanding they have inherent differences regarding this property. There was significant change (p<.05) in AM microhardness after 6 months of drowning. Regarding surface roughness, there was no significant difference (p>.05) for any material, agents and times tested. It was concluded that the contribution of these methods to human identification after burial or drowning is only possible considering the hardness, being aided by the analysis of the color change of the material. It is not possible to predict the time of burial or drowning of an individual based solely on the studied parameters
37

Resistência à flexão, sorção, solubilidade e estabilidade de cor de compósitos odontológicos reforçados por fibras / Flexural strength, water sorption, solubility and color stability of some fiber reinforced composite

Renata Souza Medeiros 10 August 2012 (has links)
Os objetivos deste estudo foram: 1) avaliar a resistência à flexão em três pontos de um compósito para uso direto (Filtek Z350 XT, 3M ESPE) e um para uso indireto (Signum, Heraeus, Kulzer) reforçados por uma ou duas camadas de fibras de polietileno (Ribbond -THM, Ribbond®) ou de vidro (Interlig, Ângelus) tratados termicamente (170°C por 10 minutos), comparados com os grupos controle (não reforçados por fibras e/ou não tratados termicamente; 2) avaliar a sorção, a solubilidade e a estabilidade de cor dos compósitos reforçados, após armazenamento em água destilada à 37°C por 14 dias. A estabilidade de cor foi avaliada com auxílio de um espectrofotômetro de contato dental (Vita EasyShade, Vident, CA, USA). Para o ensaio de resistência à flexão, foram confeccionados espécimes retangulares com dimensões de 12 x 2 x 2mm (n=10), com os seguintes fatores de variação: a) compósito (para uso direto ou indireto); b) tipo e número de camadas de fibras (vidro ou polietileno/uma ou duas camadas); c) submetidos ou não a tratamento térmico. O tratamento térmico foi realizado 24 horas após fotoativação em estufa à temperatura de 170°C por 10 minutos. O ensaio foi realizado 24 horas após fotoativação ou tratamento térmico. Para avaliação de sorção/solubilidade e estabilidade de cor, foram confeccionados espécimes em forma de disco com dimensões de 15 x 2mm (n=5), em que foram analisados os seguinte fatores: a) compósito (para uso direto ou indireto); b) tipo de fibra (vidro ou polietileno); c) número de camadas de fibras (uma ou duas). Foi realizada análise dos parâmetros de cor antes e após imersão em água deionizada por 14 dias. Os resultados foram analisados por ANOVA e teste de contraste de Tukey, com nível de significância de 5% e revelaram que a fibra de vidro, quando utilizada em duas camadas, propiciou os maiores valores de resistência à flexão para os dois compósitos testados (165,4 MPa Z350XT e 208,7MPa Signum ). O tratamento térmico não apresentou significância estatística quanto à resistência à flexão do compósito direto. Para o compósito para uso indireto (Signum ) foi encontrada diferença estatisticamente significante para o fator tratamento térmico, que indicou valores de resistência à flexão inferiores para os grupos tratados termicamente. O compósito para uso direto apresentou valor de sorção superior (33,6/cm3) ao do compósito para uso indireto (19,1/cm3). Para solubilidade, foi encontrada interação para os fatores compósito e tipo de fibra, indicando maiores valores para o compósito para uso direto associado à fibra de vidro. A análise de alteração de cor demonstrou maior valor de E para a fibra de polietileno (E =1,5) quando comparado à fibra de vidro (E=1,0). Concluiu-se que: 1) a adição de fibras propicia aumento dos valores de resistência à flexão de compósitos para uso direto e indireto, o aumento da resistência foi observado quando do uso de duas camadas de fibras; 2) o tratamento térmico à 170°C por 10 minutos não indicou melhora nas propriedades mecânicas dos compósitos reforçados; 3) adicionar fibras aos compósitos não aumentou os valores de sorção/solubilidade quando imersos em água; 4) Imersão em água não produziu alterações de cor relevantes para os compósitos reforçados com fibras se comparados aos sem fibras. / The aims of this study were: 1) to evaluate the flexural strength of one composite for direct use (Filtek Z350 XT, 3M ESPE) and one for indirect use (Signum, Heraeus, Kulzer) as a function of the reinforcement by one or two layers of polyethylene (THM-Ribbond, Ribbond ®) or glass fibers (Interlig, Angelus) submitted to heat treatment (170°C for 10 minutes) compared with control groups (not reinforced by fibers and/or not heat-treated; 2) evaluate water sorption, solubility and color stability of the reinforced composites, after storage in distilled water at 37°C for 14 days. Color stability was evaluated using a spectrophotometer (Vita Easyshade, Vident, CA, USA). For three point flexural bending test, rectangular specimens were prepared with dimensions of 12 x 2 x 2 mm (n=10), according to the following variation factors: a) composite (for direct or indirect use); b) type of fibers and number of layers (glass or polyethylene/one or two layers; c) subjected or not to heat treatment. The heat treatment was performed 24 hours after curing, in a furnace, at 170 ° C for 10 minutes. Tests were performed 24 hours after curing or heat treatment. To evaluate the water sorption/solubility and color stability, disc-shaped specimens were prepared with dimensions of 15 x 2 mm (n=5) according to the following variation factors: a) composite (for direct or indirect uses); b) fiber type (glass or polyethylene); c) number of fiber layers (one or two). Color parameters were analyze before and after immersion in deionized water for 14 days. The results were analyzed by ANOVA and Tukeys test with significance level of 5%, and indicated that the glass fiber when used in two layers, showed the highest flexural strength for the two tested composites (165.4 MPa - Z350XT and 208.7 MPa - Signum ). The heat treatment did not significantly affect the flexural strength of the direct composite. For the composite for indirect use (Signum ), a statistical significance for the factor heat treatment was found, indicating lower values of flexural strength for heat-treated groups. The composite for direct use showed higher water sorption value (33.6 /cm3) when compared to the composite for indirect use (19.1 /cm3). For solubility, a significant interaction was found for composite and fiber type, indicating higher values for direct composite and glass fiber. Color stability analysis showed higher color difference value for polyethylene fiber (E =1.5) when compared to glass fiber (E=1.0). It was concluded that: a) adding fibers increased the flexural strength values of the composites for direct or indirect use, the increase in strength was more pronounced when using two fiber layers; 2) heat treatment at 170 ° C for 10 minutes showed no improvement of the mechanical properties of fiber reinforced composites; 3) adding fibers to the composite did not increase the sorption/solubility after water immersion, 4) Immersion in water did not change the color of the fiber reinforced composites when compared with those without fibers.
38

Análise das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos à ação do calor e do frio para fins periciais / Analysis of physical and mechanical properties of dental restorative materials subjected to the action of heat and cold for forensic purposes

Roberto Cesar Biancalana 03 June 2015 (has links)
O objetivo deste trabalho foi avaliar o efeito da ação do calor e do frio sobre a estabilidade de cor, rugosidade de superfície e microdureza de restaurações de resina composta (FiltekMR Z250 XT 3M ESPE®), cimento de ionômero de vidro (KetacTM Fil Plus 3M ESPE®) e amálgama de prata em cápsulas (gs-80 SDI®), na tentativa de simular o comportamento desses materiais, quando presentes nos elementos dentais de vítimas carbonizadas ou mortas por congelamento. Foram selecionados 180 dentes bovinos que foram preparados (6 X 6 mm com 2 mm de profundidade) e separados em grupos de 30 dentes, segundo o tipo de material restaurador utilizado. Em seguida, foram realizadas as leituras iniciais de cor (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (Microdurômetro Shimadzu® Micro Hardness Tester HMV-2), que foram consideradas os padrões iniciais. Subsequentemente, os dentes foram separados aleatoriamente em grupos (n=10) segundo a temperatura utilizada para simulação de congelamento (-80°C), (-20°C) e 2,5°C; e carbonização (100°C, 200°C e 300°C). A submissão a altas temperaturas foi realizada pela colocação dos dentes restaurados em forno (ALUMINI Sinter-Press EDG®), pelo período de 15 minutos, e as baixas temperaturas foram realizadas em refrigerador (RFGE 700 GE®) a 2,5°C; congelador (CVU18 Consul®) a (-20°C) e freezer (Ultra Freezer AL 374 - 80V American Lab®) a (-80°C). Após 7 e 30 dias de ação do frio e da submissão ao calor, os dentes foram submetidos às leituras finais de cor, rugosidade e microdureza. No calor, os valores de alteração de cor (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*), dos dois materiais estéticos, rugosidade superficial e microdureza dos três materiais restauradores, foram submetidos à análise estatística One-way ANOVA, Tukey (p<0,05), tendo como fator de variação, a temperatura. No frio, os dados foram submetidos à análise estatística 2-way ANOVA, Bonferroni (p<0,05), tendo como fatores de variação, o tempo e a temperatura. Verificou-se que houve alteração de cor dos materiais estéticos, tanto nas submissões ao calor quanto ao frio. Na resina composta, a rugosidade de superfície e a microdureza não se alteraram significantemente (p>0,05), independente da temperatura a que foram submetidos. No CIV, a rugosidade e a microdureza elevaram-se nos testes ao calor; e ao frio, não ocorreram alterações significativas (p>0,05) dessas propriedades. Para o amálgama houve alteração de rugosidade significante (p<0,05) no calor, nas submissões a 300°C; e a microdureza não se modificou. Ao frio não ocorreram mudanças significantes (p>0,05) na rugosidade nem na microdureza do amálgama. Concluiu-se que os materiais estéticos podem ser distinguidos, pela análise de cor, a partir de 200°C até 300°C e quando submetidos a (-80°C), tanto em 7 dias como em 30 dias. O tempo de congelamento não é significativo para a distinção dos materiais. Testes de rugosidade e microdureza podem distinguir os materiais estéticos, independentemente, da ação do calor ou do frio. / The purpose of this study was to evaluate the effect of the action of heat and cold on color stability, surface roughness and microhardness of composite resin (FiltekMR Z250 XT 3M ESPE®), glass ionomer cement (KetacTM Fil Plus 3M ESPE®) and silver amalgam capsules (gs-80 SDI®) restorations, in an attempt to simulate the behavior of these materials when present in dental elements of carbonized or killed by freezing victims. 180 bovine teeth were selected, prepared with a 6 x 6 mm 2 mm cavity and then separated into groups of 30 teeth, according to the type of restorative material. Then, initial color readings (Spectrophotometer VITA® Easyshade), surface roughness (Rugosimeter Mitutoyo® Surftest SJ-201P) and Knoop microhardness (Shimadzu Micro Hardness tester® HMV-2) readings were performed, which were considered the initial standards. Afterwards, the teeth were randomly divided into groups (n=10) according to the temperature used for freezing simulation (-80°C), (-20°C), (2,5°C); and carbonization simulation (100°C, 200°C, 300°C). Submission to high temperatures was performed by placing the restored teeth in an oven (ALUMINI Sinter Press EDG®), for 15 minutes and for low temperatures, a refrigerator (RFGE 700 GE®) at 2,5°C, a freezer (CVU18 Consul®) at (-20°C) and an ultra freezer (Ultra Freezer AL 374 - 80V American Lab®) at (-80°C) were used. After the teeth being submitted to the action of cold and heat for 7 and 30 days, the color, surface roughness and microhardness final readings were performed. For the heat evaluation, the color change (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*) of the two aesthetic materials, and the surface roughness and microhardness of the three restorative materials, were subjected to statistical analysis (One-way ANOVA, Tukey, p<.05), with one variation factor, the temperature. For the cold evaluation, the data were statistically analyzed using 2-way ANOVA, Bonferroni, (p>.05) with two variation factors, time and temperature. Color alteration occurred for the aesthetic materials submitted to heat and cold. In the composite resin, the surface roughness and microhardness did not change (p>.05), regardless of temperature to which they were exposed. In CIV, the surface roughness and microhardness increased with the heat. After cold submission, there were no significant changes (p>.05) to these properties. For the amalgam, there was roughness change (p<.05) when submitted to heat at 300°C; the microhardness did not change. There were no significant changes in amalgam roughness or microhardness when teeth were submitted to cold (p>.05). It was concluded that the aesthetic materials can be distinguished by the color analysis, from 200°C to 300°C and when submitted to (-80°C), both after 7 days and 30 days. The freezing time is not significant for the distinction of materials. Roughness and microhardness tests can distinguish the aesthetic materials, regardless of the action of heat or cold.

Page generated in 0.0752 seconds