• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • Tagged with
  • 21
  • 21
  • 17
  • 16
  • 14
  • 12
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Previsões do comportamento carga-recalque de estaca escavada com polímero / Prediction of Load-Displacement Behavior of Bored Pile with Polymer

Alves, Débora Fonseca January 2016 (has links)
O evento de previsões do comportamento carga-recalque de uma estaca executada em solo predominantemente arenoso foi apresentado no 8° Seminário de Engenharia de Fundações Especiais e Geotecnia (SEFE8). As previsões utilizaram sondagens CPT, DMT e SPT realizadas no campo experimental de Araquari, em Santa Catarina. A estaca utilizada para o evento foi do tipo escavada com polímero, diâmetro de 100cm e comprimento de 24m. Foram recebidos pelo comitê organizador 73 previsões provenientes de 20 países, com estimativas do comportamento carga-recalque da estaca, da capacidade de carga total, lateral e de ponta e a distribuição de carga ao longo do fuste até a ruptura, definida pelo recalque de 100 mm (w/D = 10%), com um resumo dos métodos e considerações. Os dados das previsões foram comparados aos resultados obtidos em campo pela prova de carga estática da estaca instrumentada. As previsões foram majoritariamente conservadoras e o ensaio mais utilizado para determinação dos parâmetros do solo foi o CPT, tanto no meio acadêmico quanto no prático Diversos métodos foram utilizados, porém mesmo previsões que utilizaram o mesmo método apresentaram variabilidades nos resultados. Baixos valores de desvio na capacidade de carga total não significaram pequenos desvios de lateral e de ponta, mas uma combinação de desvios positivos e negativos desses. A maioria das estimativas subestimou a capacidade lateral e superestimou a de ponta. O método de Verbrugge (1981) foi utilizado em duas das cinco previsões com menores desvios de capacidade total. As curvas carga-recalque e carga-profundidade foram avaliadas quanto aos desvios médios absolutos e formatos, dados pela variância. As curvas carga-recalque com médias de até 10% utilizaram Elementos Finitos e o software UniPile, e o menor valor de variância utilizou Verbrugge (1981). As curvas carga-profundidade com médias de até 10% utilizaram Verbrugge (1981), Randolph e Wroth (1978) e Gwizdala e Steczniewski (2003), e o menor valor de variância utilizou o software UniPile. / The prediction event of load-settlement behavior of a pile built in predominantly sandy soil was presented at the 8th Foundation Engineering Seminar and Special Geotechnical (SEFE8). The predictions used tests of CPT, DMT and SPT accomplished in Araquari experimental field, in Santa Catarina. A bored pile with polymer, diameter of 100cm and length of 24m was the subject of the event. The organizing committee received 73 predictions from 20 countries, with estimates of load-settlement behavior of the pile, the total, shaft and base load capacity and the load distribution along the shaft until failure, defined by settlement of 100 mm (W/D = 10%), with a brief description of methods and considerations. Data from the predictions were compared to the results obtained in the field by static load test of the instrumented pile. The predictions were mostly conservative and the test most used for soil parameters prediction was the CPT, both in academia as in practice. Several methods were used, but even predictions that used the same method showed variability in the results Low error values in the total load capacity not meant small shaft and base errors, but a combination of positive and negative errors of these. Most estimates underestimated the shaft capacity and overestimated the base. The Verbrugge (1981) method was used in two of five predictions with lower errors of total capacity. The curves were analyzed for absolute average deviation and formats, evaluated by the variance. The load-settlement distribution with average up to 10% used Finite Element and UniPile software, and the lowest value of variance used Verbrugge (1981). The load-depth distribution with average up to 10% used Verbrugge (1981), Randolph and Wroth (1978) and Gwizdala and Steczniewski (2003), and the lowest value of variance used the UniPile software.
12

Mecanismos de transferência de carga em estacas escavadas em solos arenosos através de provas de carga instrumentadas

Sestrem, Liamara Paglia January 2018 (has links)
A experiência acumulada quanto à análise do comportamento de fundações, em relação aos diversos perfis de solos, vem confirmando a necessidade de realizar ensaios em verdadeira grandeza para avaliação de desempenho desses elementos. Aplicação de metodologias empíricas e semi-empíricas, limitadas à prática construtiva regional e às condições específicas que contemplaram o seu estabelecimento, resultam em incertezas nos métodos de previsão e dispersão entre valores de capacidade de carga medidos e previstos. Com base nessas evidências, os ensaios de prova de carga representam a técnica mais comumente empregada para previsão e avaliação da capacidade de suporte em estacas. Como resultado, obtém-se uma curva carga versus deslocamento a partir de um carregamento estático no topo do elemento. Quando executadas em estacas instrumentadas ao longo do fuste, permitem avaliar a mobilização (transferência) de resistências (cargas) ao longo da profundidade e dos carregamentos. Alternativamente, o uso de células expansivas bidirecionais, comumente denominadas de “O-cell”, vem crescendo em nível internacional e confirmando seu potencial de aplicação, embasado por vantagens que incluem a ausência de um sistema de reação e a obtenção de forma direta da resistência de ponta e atrito lateral durante os carregamentos. No intuito de contribuir para uma melhor compreensão dos mecanismos de transferência de carga envolvidos em ensaios estáticos, o presente estudo comparou resultados dessas duas metodologias através de três de ensaios estáticos convencionais e um bidirecional realizados em duas estacas escavadas de grande diâmetro em areia. A distribuição dos carregamentos medidos em função do deslocamento em termos de carga total e de atrito lateral ao longo desses quatro ensaios caracterizou-se por resultados similares. Pequenas diferenças foram observadas entre o ensaio de topo e bidirecional executados em um mesmo elemento de fundação e estão possivelmente associadas aos diferentes níveis de deformação obtidos com as duas técnicas. As condições de limpeza e integridade da ponta em estacas moldadas in loco estão associadas a incertezas ainda que os procedimentos usuais de controle e limpeza tenham sido executados. Divergências entre a parcela de contribuição de ponta ao longo dos ensaios avaliados podem estar associadas a esses fatores e a pequenas variações da geometria descritas em detalhes no trabalho. Deformações medidas pelos strain gages instalados ao longo do fuste da estaca permitiram avançar no entendimento dos mecanismos de transferência de carga existentes durante os carregamentos impostos. Os resultados indicam que o atrito começa a ser mobilizado desde os primeiros incrementos de carga e permanece se desenvolvendo com o aumento das deformações que não são constantes ao longo da profundidade. O comportamento medido ao longo do fuste varia em função do nível de confinamento e ainda da densidade relativa do solo subjacente. Os resultados permitem concluir também que ainda que existam esforços residuais atuantes, sua ordem de grandeza não reflete mudanças importantes no comportamento de elementos de fundação moldados in loco. / The gained experience in foundations behavior analysis on different soil profiles confirms the need to perform tests on full-scale elements to evaluate pile performance. Application of empirical and semi-empirical methodologies, limited to the regional constructive practice and the specific conditions that led to its establishment, result in uncertainties in the prediction and dispersion methods between measured and predicted load capacity values. Based on these evidences, the load tests represent the most commonly used technique for predicting and evaluating pile capacity. As a result, a load versus displacement curve is obtained from a static load at the top of the element. When carried out in piles instrumented along the shaft, it is possible to evaluate the mobilization (transfer) of resistances (loads) along the depth and the loads. Alternatively, the use of bidirectional expansive cells, commonly referred to as "O-cell", has been growing internationally, which confirms its potential, based on advantages that include the absence of a reaction system and obtaining the toe resistance and lateral friction directly during loading. In order to contribute to a better understanding of the load transfer mechanisms involved in static loading tests, the present study compared the results of these two methodologies through three conventional and one bidirectional load tests carried out on two large diameter bored piles. The distribution of loadings measured as a function of the displacement in terms of total load and lateral friction over these four tests was characterized by similar results. Small differences were observed between conventional top-down and bidirectional tests performed on the same foundation member and are possibly associated with the different deformation levels obtained with the two techniques. Cleaning conditions and pile toe integrity in bored piles are associated with uncertainties even though the usual control and cleaning procedures have been performed. Divergences between the contributions of the pile toe resistance along the evaluated tests may be associated with these factors and small variations of the geometry. Deformations measured by the strain gages installed along the pile shaft allowed improving the understanding of the load transfer mechanisms during the loading procedures. The results indicate that shaft friction begins to be mobilized since the first load increments and continues to increase with the strains, which are not linear along the pile shaft. The behavior measured along the shaft is a function of vertical effective stress and relative density. The results also show that although there are active residual stresses, their magnitude does not reflect important changes in the behavior of bored piles.
13

Mecanismos de transferência de carga em estacas escavadas em solos arenosos através de provas de carga instrumentadas

Sestrem, Liamara Paglia January 2018 (has links)
A experiência acumulada quanto à análise do comportamento de fundações, em relação aos diversos perfis de solos, vem confirmando a necessidade de realizar ensaios em verdadeira grandeza para avaliação de desempenho desses elementos. Aplicação de metodologias empíricas e semi-empíricas, limitadas à prática construtiva regional e às condições específicas que contemplaram o seu estabelecimento, resultam em incertezas nos métodos de previsão e dispersão entre valores de capacidade de carga medidos e previstos. Com base nessas evidências, os ensaios de prova de carga representam a técnica mais comumente empregada para previsão e avaliação da capacidade de suporte em estacas. Como resultado, obtém-se uma curva carga versus deslocamento a partir de um carregamento estático no topo do elemento. Quando executadas em estacas instrumentadas ao longo do fuste, permitem avaliar a mobilização (transferência) de resistências (cargas) ao longo da profundidade e dos carregamentos. Alternativamente, o uso de células expansivas bidirecionais, comumente denominadas de “O-cell”, vem crescendo em nível internacional e confirmando seu potencial de aplicação, embasado por vantagens que incluem a ausência de um sistema de reação e a obtenção de forma direta da resistência de ponta e atrito lateral durante os carregamentos. No intuito de contribuir para uma melhor compreensão dos mecanismos de transferência de carga envolvidos em ensaios estáticos, o presente estudo comparou resultados dessas duas metodologias através de três de ensaios estáticos convencionais e um bidirecional realizados em duas estacas escavadas de grande diâmetro em areia. A distribuição dos carregamentos medidos em função do deslocamento em termos de carga total e de atrito lateral ao longo desses quatro ensaios caracterizou-se por resultados similares. Pequenas diferenças foram observadas entre o ensaio de topo e bidirecional executados em um mesmo elemento de fundação e estão possivelmente associadas aos diferentes níveis de deformação obtidos com as duas técnicas. As condições de limpeza e integridade da ponta em estacas moldadas in loco estão associadas a incertezas ainda que os procedimentos usuais de controle e limpeza tenham sido executados. Divergências entre a parcela de contribuição de ponta ao longo dos ensaios avaliados podem estar associadas a esses fatores e a pequenas variações da geometria descritas em detalhes no trabalho. Deformações medidas pelos strain gages instalados ao longo do fuste da estaca permitiram avançar no entendimento dos mecanismos de transferência de carga existentes durante os carregamentos impostos. Os resultados indicam que o atrito começa a ser mobilizado desde os primeiros incrementos de carga e permanece se desenvolvendo com o aumento das deformações que não são constantes ao longo da profundidade. O comportamento medido ao longo do fuste varia em função do nível de confinamento e ainda da densidade relativa do solo subjacente. Os resultados permitem concluir também que ainda que existam esforços residuais atuantes, sua ordem de grandeza não reflete mudanças importantes no comportamento de elementos de fundação moldados in loco. / The gained experience in foundations behavior analysis on different soil profiles confirms the need to perform tests on full-scale elements to evaluate pile performance. Application of empirical and semi-empirical methodologies, limited to the regional constructive practice and the specific conditions that led to its establishment, result in uncertainties in the prediction and dispersion methods between measured and predicted load capacity values. Based on these evidences, the load tests represent the most commonly used technique for predicting and evaluating pile capacity. As a result, a load versus displacement curve is obtained from a static load at the top of the element. When carried out in piles instrumented along the shaft, it is possible to evaluate the mobilization (transfer) of resistances (loads) along the depth and the loads. Alternatively, the use of bidirectional expansive cells, commonly referred to as "O-cell", has been growing internationally, which confirms its potential, based on advantages that include the absence of a reaction system and obtaining the toe resistance and lateral friction directly during loading. In order to contribute to a better understanding of the load transfer mechanisms involved in static loading tests, the present study compared the results of these two methodologies through three conventional and one bidirectional load tests carried out on two large diameter bored piles. The distribution of loadings measured as a function of the displacement in terms of total load and lateral friction over these four tests was characterized by similar results. Small differences were observed between conventional top-down and bidirectional tests performed on the same foundation member and are possibly associated with the different deformation levels obtained with the two techniques. Cleaning conditions and pile toe integrity in bored piles are associated with uncertainties even though the usual control and cleaning procedures have been performed. Divergences between the contributions of the pile toe resistance along the evaluated tests may be associated with these factors and small variations of the geometry. Deformations measured by the strain gages installed along the pile shaft allowed improving the understanding of the load transfer mechanisms during the loading procedures. The results indicate that shaft friction begins to be mobilized since the first load increments and continues to increase with the strains, which are not linear along the pile shaft. The behavior measured along the shaft is a function of vertical effective stress and relative density. The results also show that although there are active residual stresses, their magnitude does not reflect important changes in the behavior of bored piles.
14

Mecanismos de transferência de carga em estacas escavadas em solos arenosos através de provas de carga instrumentadas

Sestrem, Liamara Paglia January 2018 (has links)
A experiência acumulada quanto à análise do comportamento de fundações, em relação aos diversos perfis de solos, vem confirmando a necessidade de realizar ensaios em verdadeira grandeza para avaliação de desempenho desses elementos. Aplicação de metodologias empíricas e semi-empíricas, limitadas à prática construtiva regional e às condições específicas que contemplaram o seu estabelecimento, resultam em incertezas nos métodos de previsão e dispersão entre valores de capacidade de carga medidos e previstos. Com base nessas evidências, os ensaios de prova de carga representam a técnica mais comumente empregada para previsão e avaliação da capacidade de suporte em estacas. Como resultado, obtém-se uma curva carga versus deslocamento a partir de um carregamento estático no topo do elemento. Quando executadas em estacas instrumentadas ao longo do fuste, permitem avaliar a mobilização (transferência) de resistências (cargas) ao longo da profundidade e dos carregamentos. Alternativamente, o uso de células expansivas bidirecionais, comumente denominadas de “O-cell”, vem crescendo em nível internacional e confirmando seu potencial de aplicação, embasado por vantagens que incluem a ausência de um sistema de reação e a obtenção de forma direta da resistência de ponta e atrito lateral durante os carregamentos. No intuito de contribuir para uma melhor compreensão dos mecanismos de transferência de carga envolvidos em ensaios estáticos, o presente estudo comparou resultados dessas duas metodologias através de três de ensaios estáticos convencionais e um bidirecional realizados em duas estacas escavadas de grande diâmetro em areia. A distribuição dos carregamentos medidos em função do deslocamento em termos de carga total e de atrito lateral ao longo desses quatro ensaios caracterizou-se por resultados similares. Pequenas diferenças foram observadas entre o ensaio de topo e bidirecional executados em um mesmo elemento de fundação e estão possivelmente associadas aos diferentes níveis de deformação obtidos com as duas técnicas. As condições de limpeza e integridade da ponta em estacas moldadas in loco estão associadas a incertezas ainda que os procedimentos usuais de controle e limpeza tenham sido executados. Divergências entre a parcela de contribuição de ponta ao longo dos ensaios avaliados podem estar associadas a esses fatores e a pequenas variações da geometria descritas em detalhes no trabalho. Deformações medidas pelos strain gages instalados ao longo do fuste da estaca permitiram avançar no entendimento dos mecanismos de transferência de carga existentes durante os carregamentos impostos. Os resultados indicam que o atrito começa a ser mobilizado desde os primeiros incrementos de carga e permanece se desenvolvendo com o aumento das deformações que não são constantes ao longo da profundidade. O comportamento medido ao longo do fuste varia em função do nível de confinamento e ainda da densidade relativa do solo subjacente. Os resultados permitem concluir também que ainda que existam esforços residuais atuantes, sua ordem de grandeza não reflete mudanças importantes no comportamento de elementos de fundação moldados in loco. / The gained experience in foundations behavior analysis on different soil profiles confirms the need to perform tests on full-scale elements to evaluate pile performance. Application of empirical and semi-empirical methodologies, limited to the regional constructive practice and the specific conditions that led to its establishment, result in uncertainties in the prediction and dispersion methods between measured and predicted load capacity values. Based on these evidences, the load tests represent the most commonly used technique for predicting and evaluating pile capacity. As a result, a load versus displacement curve is obtained from a static load at the top of the element. When carried out in piles instrumented along the shaft, it is possible to evaluate the mobilization (transfer) of resistances (loads) along the depth and the loads. Alternatively, the use of bidirectional expansive cells, commonly referred to as "O-cell", has been growing internationally, which confirms its potential, based on advantages that include the absence of a reaction system and obtaining the toe resistance and lateral friction directly during loading. In order to contribute to a better understanding of the load transfer mechanisms involved in static loading tests, the present study compared the results of these two methodologies through three conventional and one bidirectional load tests carried out on two large diameter bored piles. The distribution of loadings measured as a function of the displacement in terms of total load and lateral friction over these four tests was characterized by similar results. Small differences were observed between conventional top-down and bidirectional tests performed on the same foundation member and are possibly associated with the different deformation levels obtained with the two techniques. Cleaning conditions and pile toe integrity in bored piles are associated with uncertainties even though the usual control and cleaning procedures have been performed. Divergences between the contributions of the pile toe resistance along the evaluated tests may be associated with these factors and small variations of the geometry. Deformations measured by the strain gages installed along the pile shaft allowed improving the understanding of the load transfer mechanisms during the loading procedures. The results indicate that shaft friction begins to be mobilized since the first load increments and continues to increase with the strains, which are not linear along the pile shaft. The behavior measured along the shaft is a function of vertical effective stress and relative density. The results also show that although there are active residual stresses, their magnitude does not reflect important changes in the behavior of bored piles.
15

Comportamento de estacas escavadas em solos colapsíveis / Behavior of excavated piles in collapsible soils

Teixeira, Cornélio Zampier 28 June 1993 (has links)
Este trabalho se propõe a analisar os efeitos produzidos pela inundação do solo em estacas escavadas, isoladas, submetidas a esforços de compressão. Os resultados obtidos referem-se à execução de três provas de carga lentas em estacas com diâmetros de 0,40 m e 0,50 m (2 provas de carga distintas) e comprimentos de 10,0 m, submetidas anteriormente a uma série de carregamentos (duas provas de carga rápidas e duas lentas). Os resultados relativos aos deslocamentos medidos no topo das estacas e os obtidos pela instrumentação instalada ao longo do fuste são então comparados com a sequência dos resultados anteriores, para avaliação do efeito de umedecimento no comportamento \"carga x recalque\" e nos mecanismos de transferência de carga. É feita ainda uma descrição minuciosa do processo utilizado para inundação do solo e uma breve consideração sobre os efeitos da não reposição de cargas em ensaios lentos, de longa duração. / This work intends to analyze the effects produced by the flooding of the soilexcavated piles, isolated, subjected to compression efforts. The results refer to the execution of three slow load tests on piles with diameters of 0.40 m and 0.50 m (2 distinct load tests) and 10.0 m lengths, submitted previously to a number of shipments (two slow and two quick load). The results concerning offsets measured at the top of the stakes and those obtained by the instrumentation installed along the forend are then compared with the sequence of the previous results, to evaluate the effect of damping in behavior \"load x settlement\" and load transfer mechanisms. It was also made a thorough description of the process used to flood the ground and a brief consideration of the effects of non-replacement of loads in slow, long-term trials.
16

Provas de cargas estáticas instrumentadas em profundidade em estacas escavadas de grande diâmetro (Estações). / Static loading tests instrumented in large diameter drilled piles.

França, Danilo Costa de 30 September 2011 (has links)
Objetivou-se estudar o comportamento de estacas escavadas de grande diâmetro em uma obra de um Shopping Center na cidade de São Paulo. As estacas foram submetidas a carregamentos axiais de compressão, sendo que as estacas foram instrumentadas em profundidade. Utilizou-se de teorias amplamente conhecidas no meio técnico com o propósito de interpretar as curvas carga vs recalque, obtendo-se resultados como os diagramas de transferência de carga ao longo do fuste e atrito lateral unitário, gráficos do produto ES das estacas ensaiadas, gráficos de rigidez das estacas e as duas relações modificadas de Cambefort. O presente trabalho visa conseguir parâmetros que pudessem proporcionar uma redução no comprimento das estacas em obra e apresentar resultados que auxiliem os projetistas no dimensionamento de fundações usando-se estacas escavadas de grande diâmetro, sempre tendo cuidado e critério na extrapolação dos resultados em solos diferentes dos apresentados aqui. / The objective of this Msc Thesis is to study the behavior of large diameter drilled pile in the construction of a shopping mall in Sao Paulo. The piles were subjected to axial compression loads and instrumented in depth. Widely known theories were used to interpret load vs settlement curves, obtaining such results as transfer loads diagrams along the shaft and lateral friction unit, ES product and stiffness grafics of tested piles and two modified Cambefort Laws. This paper aims to achieve parameters that will allow a reduction in pile lengths and to present results that will aid designers in the design of large diameter drilled pile, provided that the needed care is taken when extrapolating results to soils of different geological origins from those presented here.
17

Comportamento de estacas escavadas em solos colapsíveis / Behavior of excavated piles in collapsible soils

Cornélio Zampier Teixeira 28 June 1993 (has links)
Este trabalho se propõe a analisar os efeitos produzidos pela inundação do solo em estacas escavadas, isoladas, submetidas a esforços de compressão. Os resultados obtidos referem-se à execução de três provas de carga lentas em estacas com diâmetros de 0,40 m e 0,50 m (2 provas de carga distintas) e comprimentos de 10,0 m, submetidas anteriormente a uma série de carregamentos (duas provas de carga rápidas e duas lentas). Os resultados relativos aos deslocamentos medidos no topo das estacas e os obtidos pela instrumentação instalada ao longo do fuste são então comparados com a sequência dos resultados anteriores, para avaliação do efeito de umedecimento no comportamento \"carga x recalque\" e nos mecanismos de transferência de carga. É feita ainda uma descrição minuciosa do processo utilizado para inundação do solo e uma breve consideração sobre os efeitos da não reposição de cargas em ensaios lentos, de longa duração. / This work intends to analyze the effects produced by the flooding of the soilexcavated piles, isolated, subjected to compression efforts. The results refer to the execution of three slow load tests on piles with diameters of 0.40 m and 0.50 m (2 distinct load tests) and 10.0 m lengths, submitted previously to a number of shipments (two slow and two quick load). The results concerning offsets measured at the top of the stakes and those obtained by the instrumentation installed along the forend are then compared with the sequence of the previous results, to evaluate the effect of damping in behavior \"load x settlement\" and load transfer mechanisms. It was also made a thorough description of the process used to flood the ground and a brief consideration of the effects of non-replacement of loads in slow, long-term trials.
18

Estudo da interação solo-concreto das estacas escavadas do campo experimental de Araquari

Lavalle, Laura Vanessa Araque January 2017 (has links)
Procurando diminuir as incertezas a respeito do comportamento de estacas em perfis arenosos, desenvolveu-se um campo experimental localizado em Araquari-SC, conduzido pela Universidade Federal do Rio Grande do Sul, no qual foram executados (a) ensaios de campo para definir as condições geotécnicas do solo, (b) estacas escavadas e hélice continua e (c) provas de carga estática nos elementos estruturais. O presente trabalho tem como objetivo estudar as variáveis que intervêm no mecanismo de transferência de carga ao solo. Mediante ensaios de laboratório, caracterizou-se o solo presente no campo experimental, definiram-se os parâmetros de resistência, mineralogia, forma, distribuição e tamanho das partículas, para serem usadas na retro análise do coeficiente de pressão de solo (ks) das provas de carga. Para esta finalidade foram analisados os resultados medidos em estacas escavadas executadas com bentonita e polímero. A retro análise foi realizada através do método beta (β), abordagem que permite a obtenção da capacidade lateral das estacas construídas em perfis arenosos, baseado nas tensões verticais, no coeficiente de pressão de solo e no ângulo de atrito da interface solo-estaca. Devido à interação entre as partículas do solo e concreto da estaca, estas são mobilizadas a elevados níveis de deformações, o ângulo de atrito da interface é considerado próximo ao ângulo de atrito no estado crítico da areia. O solo presente no campo experimental corresponde a areia fina com lentes de silte. Assim, os parâmetros de resistência definidos foram o ângulo de atrito no estado crítico e de pico com valores de 33,0° e 33,4° respetivamente. O ângulo no estado crítico foi utilizado na retro análise das provas de carga e como resultado foi obtido o ks, para posteriormente ser comparado ao coeficiente de empuxo no repouso (k0). Os resultados mostraram que com a profundidade o valor ks aproxima-se ao valor de k0, apresentado uma relação de ks/k0 próxima a unidade. Conclui-se que, o mecanismo de transferência de carga entre o solo e a estaca pode ser avaliado em função das tensões iniciais do depósito, expressas a partir de k0 estimado com base nos ensaios de laboratório. / In order to reduce the uncertainties regarding the behavior of piles in sandy profiles, an experimental field was developed by the Federal University of Rio Grande do Sul in Araquari-SC, where were executed (a) field tests to define soil geotechnical conditions, (b) bored and continuous flight auger piles and (c) static load tests on the structural elements. The aim of this research was to study the variables that intervene in the soil load transfer mechanism. The soil at the experimental field was characterized by laboratory tests, and parameters of resistance, mineralogy, particle shape, distribution and size were obtained for use in the back analysis of the soil pressure coefficient (ks) of the load tests. For this purpose, were analyzed the results measured on bored piles executed with bentonite and polymer. The back analysis was made using the beta method (β), which allows to estimate the lateral capacity of the piles constructed in sandy profiles, based on vertical stresses, soil pressure coefficient and friction angle of the soil-pile interface. Due to the interaction between the soil particles and the pile concrete, the first are mobilized at high deformation levels, the friction angle of the interface is considered close to the friction angle in the sand critical state. The soil present in the experimental field corresponds to fine sand with silt lenses. Thus, the resistance parameters defined were the critical state and peak friction angle with values of 33.0 ° and 33.4 ° respectively. The critical state angle was used in the back analysis of the load tests, and as a result the ks was obtained, to be subsequently compared to the at rest lateral earth pressure coefficient (k0). The results showed that, with depth, the value ks approaches the value of k0, with a relation of ks / k0 close to unity. It is concluded that the load transfer mechanism between the soil and the pile can be evaluated as a function of the initial stresses of the deposit, expressed from an estimated k0 based on the laboratory tests.
19

Estudo da interação solo-concreto das estacas escavadas do campo experimental de Araquari

Lavalle, Laura Vanessa Araque January 2017 (has links)
Procurando diminuir as incertezas a respeito do comportamento de estacas em perfis arenosos, desenvolveu-se um campo experimental localizado em Araquari-SC, conduzido pela Universidade Federal do Rio Grande do Sul, no qual foram executados (a) ensaios de campo para definir as condições geotécnicas do solo, (b) estacas escavadas e hélice continua e (c) provas de carga estática nos elementos estruturais. O presente trabalho tem como objetivo estudar as variáveis que intervêm no mecanismo de transferência de carga ao solo. Mediante ensaios de laboratório, caracterizou-se o solo presente no campo experimental, definiram-se os parâmetros de resistência, mineralogia, forma, distribuição e tamanho das partículas, para serem usadas na retro análise do coeficiente de pressão de solo (ks) das provas de carga. Para esta finalidade foram analisados os resultados medidos em estacas escavadas executadas com bentonita e polímero. A retro análise foi realizada através do método beta (β), abordagem que permite a obtenção da capacidade lateral das estacas construídas em perfis arenosos, baseado nas tensões verticais, no coeficiente de pressão de solo e no ângulo de atrito da interface solo-estaca. Devido à interação entre as partículas do solo e concreto da estaca, estas são mobilizadas a elevados níveis de deformações, o ângulo de atrito da interface é considerado próximo ao ângulo de atrito no estado crítico da areia. O solo presente no campo experimental corresponde a areia fina com lentes de silte. Assim, os parâmetros de resistência definidos foram o ângulo de atrito no estado crítico e de pico com valores de 33,0° e 33,4° respetivamente. O ângulo no estado crítico foi utilizado na retro análise das provas de carga e como resultado foi obtido o ks, para posteriormente ser comparado ao coeficiente de empuxo no repouso (k0). Os resultados mostraram que com a profundidade o valor ks aproxima-se ao valor de k0, apresentado uma relação de ks/k0 próxima a unidade. Conclui-se que, o mecanismo de transferência de carga entre o solo e a estaca pode ser avaliado em função das tensões iniciais do depósito, expressas a partir de k0 estimado com base nos ensaios de laboratório. / In order to reduce the uncertainties regarding the behavior of piles in sandy profiles, an experimental field was developed by the Federal University of Rio Grande do Sul in Araquari-SC, where were executed (a) field tests to define soil geotechnical conditions, (b) bored and continuous flight auger piles and (c) static load tests on the structural elements. The aim of this research was to study the variables that intervene in the soil load transfer mechanism. The soil at the experimental field was characterized by laboratory tests, and parameters of resistance, mineralogy, particle shape, distribution and size were obtained for use in the back analysis of the soil pressure coefficient (ks) of the load tests. For this purpose, were analyzed the results measured on bored piles executed with bentonite and polymer. The back analysis was made using the beta method (β), which allows to estimate the lateral capacity of the piles constructed in sandy profiles, based on vertical stresses, soil pressure coefficient and friction angle of the soil-pile interface. Due to the interaction between the soil particles and the pile concrete, the first are mobilized at high deformation levels, the friction angle of the interface is considered close to the friction angle in the sand critical state. The soil present in the experimental field corresponds to fine sand with silt lenses. Thus, the resistance parameters defined were the critical state and peak friction angle with values of 33.0 ° and 33.4 ° respectively. The critical state angle was used in the back analysis of the load tests, and as a result the ks was obtained, to be subsequently compared to the at rest lateral earth pressure coefficient (k0). The results showed that, with depth, the value ks approaches the value of k0, with a relation of ks / k0 close to unity. It is concluded that the load transfer mechanism between the soil and the pile can be evaluated as a function of the initial stresses of the deposit, expressed from an estimated k0 based on the laboratory tests.
20

Estudo da interação solo-concreto das estacas escavadas do campo experimental de Araquari

Lavalle, Laura Vanessa Araque January 2017 (has links)
Procurando diminuir as incertezas a respeito do comportamento de estacas em perfis arenosos, desenvolveu-se um campo experimental localizado em Araquari-SC, conduzido pela Universidade Federal do Rio Grande do Sul, no qual foram executados (a) ensaios de campo para definir as condições geotécnicas do solo, (b) estacas escavadas e hélice continua e (c) provas de carga estática nos elementos estruturais. O presente trabalho tem como objetivo estudar as variáveis que intervêm no mecanismo de transferência de carga ao solo. Mediante ensaios de laboratório, caracterizou-se o solo presente no campo experimental, definiram-se os parâmetros de resistência, mineralogia, forma, distribuição e tamanho das partículas, para serem usadas na retro análise do coeficiente de pressão de solo (ks) das provas de carga. Para esta finalidade foram analisados os resultados medidos em estacas escavadas executadas com bentonita e polímero. A retro análise foi realizada através do método beta (β), abordagem que permite a obtenção da capacidade lateral das estacas construídas em perfis arenosos, baseado nas tensões verticais, no coeficiente de pressão de solo e no ângulo de atrito da interface solo-estaca. Devido à interação entre as partículas do solo e concreto da estaca, estas são mobilizadas a elevados níveis de deformações, o ângulo de atrito da interface é considerado próximo ao ângulo de atrito no estado crítico da areia. O solo presente no campo experimental corresponde a areia fina com lentes de silte. Assim, os parâmetros de resistência definidos foram o ângulo de atrito no estado crítico e de pico com valores de 33,0° e 33,4° respetivamente. O ângulo no estado crítico foi utilizado na retro análise das provas de carga e como resultado foi obtido o ks, para posteriormente ser comparado ao coeficiente de empuxo no repouso (k0). Os resultados mostraram que com a profundidade o valor ks aproxima-se ao valor de k0, apresentado uma relação de ks/k0 próxima a unidade. Conclui-se que, o mecanismo de transferência de carga entre o solo e a estaca pode ser avaliado em função das tensões iniciais do depósito, expressas a partir de k0 estimado com base nos ensaios de laboratório. / In order to reduce the uncertainties regarding the behavior of piles in sandy profiles, an experimental field was developed by the Federal University of Rio Grande do Sul in Araquari-SC, where were executed (a) field tests to define soil geotechnical conditions, (b) bored and continuous flight auger piles and (c) static load tests on the structural elements. The aim of this research was to study the variables that intervene in the soil load transfer mechanism. The soil at the experimental field was characterized by laboratory tests, and parameters of resistance, mineralogy, particle shape, distribution and size were obtained for use in the back analysis of the soil pressure coefficient (ks) of the load tests. For this purpose, were analyzed the results measured on bored piles executed with bentonite and polymer. The back analysis was made using the beta method (β), which allows to estimate the lateral capacity of the piles constructed in sandy profiles, based on vertical stresses, soil pressure coefficient and friction angle of the soil-pile interface. Due to the interaction between the soil particles and the pile concrete, the first are mobilized at high deformation levels, the friction angle of the interface is considered close to the friction angle in the sand critical state. The soil present in the experimental field corresponds to fine sand with silt lenses. Thus, the resistance parameters defined were the critical state and peak friction angle with values of 33.0 ° and 33.4 ° respectively. The critical state angle was used in the back analysis of the load tests, and as a result the ks was obtained, to be subsequently compared to the at rest lateral earth pressure coefficient (k0). The results showed that, with depth, the value ks approaches the value of k0, with a relation of ks / k0 close to unity. It is concluded that the load transfer mechanism between the soil and the pile can be evaluated as a function of the initial stresses of the deposit, expressed from an estimated k0 based on the laboratory tests.

Page generated in 0.0496 seconds