• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação ecocardiografica da terapia de ressincronização cardiaca : dois anos de seguimento / Echocardiographic assessment of the cardiac resynchronization therapy : two years of follow-up

Veiga, Viviane Cordeiro, 1976- 12 August 2018 (has links)
Orientador: Salomon Soriano Ordinola Rojas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T15:05:14Z (GMT). No. of bitstreams: 1 Veiga_VivianeCordeiro_M.pdf: 4383215 bytes, checksum: 4ac235c87c9173ad91395fd7c6466208 (MD5) Previous issue date: 2008 / Resumo: Introdução A terapia de ressincronização cardíaca é uma opção efetiva nos pacientes com insuficiência cardíaca avançada. No entanto, 20 a 30% dos pacientes não apresentam benefícios à esta terapêutica. Critérios clínicos, eletrocardiográficos e ecocardiográficos têm sido estudados na tentativa de selecionar os pacientes que serão beneficiados com a ressincronização cardíaca, sendo o ecocardiograma um método utilizado tanto na seleção, quanto na avaliação e otimização desta terapêutica. Objetivo: O objetivo deste trabalho é analisar a utilização do ecocardiograma na avaliação da terapia de ressincronização cardíaca em pacientes portadores de insuficiência cardíaca refratária, no seguimento a curto prazo (dez dias) e após dois anos de evolução. Casuística e Método: Foram avaliados 20 pacientes com indicação de implante de marcapasso biventricular para terapia de ressincronização cardíaca no período de dois anos, sendo 16 (80%) do sexo masculino, com idade variando de 27 a 80 anos (59,70 ± 12,59 anos). A etiologia da cardiomiopatia era isquêmica em 10 pacientes (50%), chagásica em seis (30%) e idiopática em 4 (20%). Quinze pacientes encontravam-se em classe funcional III (New York Heart Association) e cinco em classe funcional IV no momento do implante do marcapasso. Foi aplicado o Questionário de Qualidade de Vida de Minnesota e realizado o teste de caminhada de seis minutos para avaliação das condições clínicas dos pacientes. Realizado ecodopplercardiograma bidimensional para avaliação da função ventricular, diâmetros cavitários, índice de performance miocárdica, estudo da dissincronia interventricular (avaliação do atraso eletromecânico entre os ventrículos esquerdo e direito) e intraventricular (análise pelo modo unidimensional e Doppler tecidual), da função diastólica e do grau da regurgitação mitral. Dez dias após o implante do marcapasso biventricular, foi repetida toda a avaliação inicial e, novamente, após dois anos. Resultados: Em dois anos, cinco pacientes (25%) foram à óbito, sendo que destes, quatro apresentavam etiologia chagásica. A duração média do complexo QRS era de 154,5±18,48 x 129,0±22,91 x 134,0±24,14 ms, respectivamente nos períodos pré-operatório, dez dias e dois anos de pós-operatório. Não houve alteração estatisticamente significante da fração de ejeção entre os períodos pré-operatório e dez dias, mas houve alteração significante entre os períodos pré-operatório e dois anos e dez dias e dois anos. No seguimento de dez dias, houve piora da dissincronia intraventricular avaliada pelo Doppler tecidual, assim como a pontuação no escore de qualidade de vida foi maior, no grupo óbito. Conclusão: A ecocardiografia é uma tecnologia em evolução e dos parâmetros avaliados, somente a avaliação da dissincronia intraventricular pelo Doppler tecidual após o procedimento, foi capaz de predizer a eficácia da terapia de ressincronização cardíaca, em relação à mortalidade. Não houve correlação entre os parâmetros ecocardiográficos e a melhora clínica de alguns pacientes. / Abstract: Introduction In the cardiac resynchronization therapy is an effective option for patients with advanced heart failure. However, 20 to 30% of patients did not show benefits to this therapy. Clinical criteria, electrocardiography and the echocardiography have been studied in an attempt to select the patients who will benefit from the cardiac resynchronization, and the echocardiogram is a method used in both the selection, as in the evaluation and optimization of this therapy. Objective: The objective of this study is to evaluate the use of echocardiography in the evaluation of patients undergoing cardiac resynchronization therapy for a period of two years. Patients and Methods: We evaluated 20 patients with the implantation of biventricular pacemaker for cardiac resynchronization therapy for over two years, and 16 (80%) males, ranging in age from 27 to 80 years (59.70±12.59 years). The etiology of cardiomyopathy was ischemic in 10 patients (50%), Chagas disease in six (30%) and idiophatic in 4 (20%). Fifteen patients were in functional class III (New York Heart Association) and five in functional class IV at the time of implantation of the pacemaker. We applied the Quality of Life Questionnaire of Minnesota and conducted the test of a six-minute walk to evaluate the clinical conditions of patients. Directed two-dimensional Doppler echocardiography for evaluation of ventricular function, cavity diameters, myocardial performance index, study of interventricular dyssynchrony (eletromechanical delay left ventricle - the right ventricle) and intraventricular (by way dimensional analysis and tissue Doppler), the diastolic function and degree of mitral regurgitation. Ten days after implantation of biventricular pacemaker, was repeated throughout the initial assessment and again after two years. Results: In two years, five patients (25%) were to death, and that these, four had Chagas disease. The average duration of the QRS complex was 154.5±18.48 x 129.0±22.91 x 134.0±24.14 ms, respectively in preoperative, ten days and two years after surgery. There was no statistically significant change in the ejection fraction between preoperative and ten days but there was significant change between periods preoperative and 2 years and 10 days and 2 years. Following ten days, the evaluation of intraventricular dyssynchrony by tissue Doppler and quality of life scores were significantly higher in the group died. Conclusion: The echocardiography is an evolving technology and the parameters evaluated, only the assessment of intraventricular dyssynchrony by Doppler tissue after the procedure was able to predict the effectiveness of the cardiac resynchronization therapy, in relation to mortality. There was no correlation between echocardiographic parameters and clinical improvement in some patients. / Mestrado / Mestre em Cirurgia
2

Estimulação multidirecional de celulas cardiacas : instrumentação e experimentação / Multidirectional stimulation of cardiac cells : instrumentation and experimentation

Fonseca, Alexandra Valenzuela Santelices da 12 March 2009 (has links)
Orientadores: Jose Wilson Magalhaes Bassani, Rosana Almada Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T01:38:31Z (GMT). No. of bitstreams: 1 Fonseca_AlexandraValenzuelaSantelicesda_M.pdf: 1311974 bytes, checksum: ab061a6f8d63a1175d6a3c9281e0704e (MD5) Previous issue date: 2009 / Resumo: O procedimento mais efetivo para reverter arritmias cardíacas consiste na aplicação de choques elétricos de alta intensidade, como e o caso da desfibrilação. Estimulação com campos elétricos (E) elevados, entretanto, exerce efeitos deletérios sobre o músculo cardíaco, podendo causar disfunções elétrica e contrátil e até a morte celular. Privilegiar a estimulação na direção longitudinal, para qual o limiar de excitação das células cardíacas e menor, seria uma forma de se reduzir a amplitude do estimulo sem perder a efetividade da estimulação. Para isto, foi desenvolvido e testado, em miócitos ventriculares orientados de maneira aleatória, um sistema de estimulação multidirecional automática que permite o chaveamento controlado de estímulos sequênciais para três diferentes pares de eletrodos (cada um correspondendo a uma direção) em um intervalo de tempo inferior a duração do potencial de ação (período em que a célula se encontra eletricamente refrataria). A estimulação multidirecional com uma intensidade de E 20% acima do limiar estimulatório (1,2× ETM) dobrou o recrutamento (excitação) de células (80 vs. 40% com estimulação unidirecional, p<0,001). Adicionalmente, o recrutamento com a estimulação multidirecional automática foi maior (p< 0,001) do que a soma dos recrutamentos obtidos com a estimulação em cada direção individualmente (sem intersecção), o que sugere que a estimulação sublimiar durante o procedimento automático pode aumentar a excitabilidade celular. Foi observado também que, para uma dada amplitude do estimulo, o uso da forma de onda bipolar (para a qual o valor de ETM foi menor que para pulsos monopolares: 3,2 ± 0,1 vs. 3,9 ± 0,1 V/cm; p< 0,001) promoveu um recrutamento maior do que com o pulso monopolar (recrutamento de 50% das células foi obtido com 2,97 ± 0,04 e 4,18 ± 0,05 V/cm para pulsos bipolares e monopolares, respectivamente; p< 0,05). A combinação da estimulação multidirecional automática com o uso da forma de onda bipolar permitiu, portanto, uma redução de cerca de 50% no valor do E absoluto (3,8 vs. 7,8 V/cm com estimulação unidirecional e pulso monopolar) para um recrutamento de ~80% das células. A aplicação destes procedimentos na estimulação cardíaca (marcapasso e desfibrilação) pode otimizar o processo, levando a uma melhor eficiência e uma menor incidência de lesão. / Abstract: The most effective procedure to revert cardiac arrhythmias consists in the application of high intensity electric discharge, such as in cardiac defibrillation. Nevertheless, stimulation using high electric fields (E) may cause injury to the cardiac muscle, generating electric and contractile dysfunctions and even cell death. A possible way to reduce the stimulus intensity while maintaining the stimulation effectiveness would be stimulate cardiac cells with E applied parallel to the cell major axis, in which case the stimulation threshold is lower. To test this possibility, a multidirectional stimulation system was developed and tested on randomly-oriented rat ventricular myocytes. The system allows the controlled switching of sequential stimuli delivered to three different pairs of electrodes (each one corresponding to one direction), in a period shorter than the action potential duration (when cell is electrically refractory). The multidirectional stimulation with E intensity 20% above the stimulation threshold (1.2× ETM) doubled the percentage of recruited (excited) cells (~80 vs. ~40 % with unidirectional stimulation, p<0.001). Additionally, recruitment with automatic multidirectional stimulation was greater (p< 0.001) than the sum of recruitments obtained from stimulation of each direction individually (without intersection), which is suggestive that subthreshold stimulation during the automatic procedure might enhance cell excitability. Moreover, it was observed that for a given absolute stimulus amplitude, the use of biphasic waveforms (for which ETM was lower than for monophasic pulses: 3.2 ± 0.1 vs. 3.9 ± 0.1 V/cm; p< 0.001) promoted higher recruitment than monophasic stimuli (50% recruitment was attained with 2.97 ± 0.04 and 4.18 ± 0.05 V/cm with biphasic and monophasic pulses, respectively; p< 0.05). Thus, the association of automatic multidirectional stimulation and biphasic waveform enabled a 50% reduction of the absolute E value (3.8 vs. 7.8 V/cm with unidirectional stimulation and monopolar pulse) to evoke excitation in ~80% of the cells. The application of these procedures to cardiac stimulation (pacemaker and defibrillation) might optimize the process, leading to greater efficiency and lower injury incidence. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Page generated in 0.0645 seconds