• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Commande prédictive des systèmes hybrides et application à la commande de systèmes en électronique de puissance. / Predictive control of hybrid systems and its application to the control of power electronics systems

Vlad, Cristina 21 March 2013 (has links)
Actuellement la nécessité des systèmes d’alimentation d’énergie, capables d’assurer un fonctionnement stable dans des domaines de fonctionnement assez larges avec des bonnes performances dynamiques (rapidité du système, variations limitées de la tension de sortie en réponse aux perturbations de charge ou de tension d’alimentation), devient de plus en plus importante. De ce fait, cette thèse est orientée sur la commande des convertisseurs de puissance DC-DC représentés par des modèles hybrides.En tenant compte de la structure variable de ces systèmes à commutation, un modèle hybride permet de décrire plus précisément le comportement dynamique d’un convertisseur dans son domaine de fonctionnement. Dans cette optique, l’approximation PWA est utilisée afin de modéliser les convertisseurs DC-DC. A partir des modèles hybrides développés, on s’est intéressé à la stabilisation des convertisseurs au moyen des correcteurs à gains commutés élaborés sur la base de fonctions de Lyapunov PWQ, et à l’implantation d’une commande prédictive explicite, en considérant des contraintes sur l’entrée de commande. La méthode de modélisation et les stratégies de commande proposées ont été appliquées sur deux topologies : un convertisseur buck, afin de mieux maîtriser le réglage des correcteurs et un convertisseur flyback avec filtre d’entrée. Cette dernière topologie nous a permis de répondre aux difficultés du point de vue de la commande (comportement à déphasage non-minimal) rencontrées dans la majorité des convertisseurs DC-DC. Les performances des commandes élaborées ont été validées en simulation sur les topologies considérées et expérimentalement sur une maquette du convertisseur buck. / Lately, power supply systems, guaranteeing the global stability for large enough operation ranges with good dynamic performances (small settling time, bounded overshoot of the output voltage in the presence of load or supply voltage variations), are strongly needed. Therefore, this thesis deals with control problems of DC-DC power converters represented by hybrid models.Considering the variable structure of these switched systems, a hybrid model describes more precisely the converter’s dynamics in its operating domain. From this perspective, a PWA (piecewise affine) approximation is used in order to model the DC-DC converters. Based on the developed hybrid models, first we have designed a stable piecewise linear state-feedback controller using piecewise quadratic (PWQ) Lyapunov functions, and secondly, we have implemented an explicit predictive control law taking into account constraints on the control input. The hybrid modeling technique and the proposed control strategies were applied on two different topologies of converters: a buck converter, in order to have a thorough knowledge of the controllers’ tuning, and a flyback converter with an input filter. This last topology, allowed us to manage different control problems (non-minimum phase behavior) encountered in the majority of topologies of DC-DC power converters. The controllers’ performances were validated in simulation on both considered topologies and also experimentally on buck converter.
2

Supervisory model predictive control of building integrated renewable and low carbon energy systems

Sadr, Faramarz January 2012 (has links)
To reduce fossil fuel consumption and carbon emission in the building sector, renewable and low carbon energy technologies are integrated in building energy systems to supply all or part of the building energy demand. In this research, an optimal supervisory controller is designed to optimize the operational cost and the CO2 emission of the integrated energy systems. For this purpose, the building energy system is defined and its boundary, components (subsystems), inputs and outputs are identified. Then a mathematical model of the components is obtained. For mathematical modelling of the energy system, a unified modelling method is used. With this method, many different building energy systems can be modelled uniformly. Two approaches are used; multi-period optimization and hybrid model predictive control. In both approaches the optimization problem is deterministic, so that at each time step the energy consumption of the building, and the available renewable energy are perfectly predicted for the prediction horizon. The controller is simulated in three different applications. In the first application the controller is used for a system consisting of a micro-combined heat and power system with an auxiliary boiler and a hot water storage tank. In this application the controller reduces the operational cost and CO2 emission by 7.31 percent and 5.19 percent respectively, with respect to the heat led operation. In the second application the controller is used to control a farm electrification system consisting of PV panels, a diesel generator and a battery bank. In this application the operational cost with respect to the common load following strategy is reduced by 3.8 percent. In the third application the controller is used to control a hybrid off-grid power system consisting of PV panels, a battery bank, an electrolyzer, a hydrogen storage tank and a fuel cell. In this application the controller maximizes the total stored energies in the battery bank and the hydrogen storage tank.

Page generated in 0.0144 seconds