• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lumière sur la zircone 3Y-TZP utilisée en implantologie orale : Etude de la relation entre la microstructure et la durabilité / Light on zirconia 3Y-TZP used oral implantology : Study of the relationship between microstructure and durability

Sanon, Clarisse 15 December 2014 (has links)
La zircone 3Y-TZP présente un grand intérêt pour les applications dentaires, en implantologie orale, elle semble être un matériau extrêmement prometteur: elle allie une biocompatibilité à un aspect esthétique satisfaisant et présente aussi des propriétés mécaniques très supérieures aux autres céramiques. Ces bonnes propriétés mécaniques sont intimement liées à la microstructure du matériau, elle-même directement liée aux procédés d’élaboration comme nous l’a rappelé l’alarmante série de ruptures de plus de 800 têtes de prothèses de hanche en zircone au début des années 2000, due au phénomène de vieillissement de ce matériau. Cependant, les études cliniques menées à ce jour ne font toujours pas état des interrelations existant entre la microstructure, les propriétés mécaniques et la sensibilité au vieillissement. Il était donc primordial de valider et d’appliquer les connaissances acquises dans le domaine des sciences des matériaux pour l’application de la zircone 3Y-TZP en implantologie oral. C’est l’objectif de notre première publication. Nous avons également développé, dans notre deuxième publication, un protocole d’évaluation permettant dans un premier temps, d’évaluer l’effet de l’état de surface et de la microstructure sur la résistance mécanique d’implants neufs, puis de suivre leurs cinétiques de vieillissement tout en analysant l’évolution de la microstructure et son influence sur la résistance mécanique au cours du vieillissement. Tout cela permettant in fine, de prédire la durabilité d’un type d’implant. Nous avons par la suite, développé un programme informatique permettant la détection et la quantification du vieillissement pour un volume donné. Cette détection de la zone vieillie ou transformée est basée sur des modifications microstructurales caractéristiques engendrées lors du vieillissement. Enfin, nous avons pu mettre en évidence l’occurrence du phénomène de vieillissement in vivo, par l’analyse d’explants issus d’une étude clinique et démontrer leur probable implication dans ces cas d’échec. Le logiciel informatique de traitement d’image développé a été également, appliqué aux explants dans le but de mettre en lumière et d’expliciter l’occurrence du phénomène de vieillissement in vivo, afin de sensibiliser les acteurs de ce marcher aux problématiques rencontrées et d’optimiser de ce dispositif médical, à la lumière des connaissances actuelles. / 3Y-TZP zirconia is gaining interest in oral implantology, it seems to be a promising material with good biocompatibility, esthetic appearance and also the highest mechanical properties for a ceramic. These mechanical properties are closely related to the microstructure of the material itself directly related to production processes as we recalled the alarming series of breaks of more than 800 heads of zirconia hip replacements in the early 2000, due to the aging phenomenon of the material. However, clinical studies to date are still not state of the interrelationships between microstructure, mechanical properties and sensitivity to aging. It was therefore important to validate and apply the knowledge gained in the field of materials science for the application of 3Y-TZP zirconia oral implantology. This is the goal of our first publication. We also have developed in our second publication, a protocol to assess the effect of the surface modification and microstructure on the mechanical strength of new implants and follow their kinetics of aging and also, the evolution of the microstructure and its influence on the mechanical strength during aging, to predict the durability of a type of implant. We have subsequently developed a computer program for the detection and quantification of the aging for a given volume. This detection of the aged or transformed area is based on microstructural modifications produced during aging. Finally, we have been able to demonstrate the occurrence of the phenomenon of aging in vivo, by analyzing explants from a clinical study and demonstrate their involvement in the case of dental implant failure. The image processing developed was also applied to the explants in order to highlight and explain the occurrence of in vivo aging phenomenon. The objective is to optimize this medical device, in the light of current knowledge.
2

Magnetoelastische Sensoren für die Überwachung von mechanischen Verformungen in Verbundwerkstoffen

Wielage, Bernhard, Mäder, Thomas, Weber, Daisy, Mucha, Herbert 08 March 2013 (has links)
Eine ortsauflösende Spannungs- und Dehnungssensortechnik soll durch die Nutzung magnetostriktiver Materialien auf der Oberfläche von Kohlenstoffeinzelfasern (C-Fasern) und Mikrofeinstrukturierung dieser Schichten erzeugt und zur elektronischen Überwachung des Belastungszustandes von sicherheits- oder servicerelevanten Faserverbundbauteilen eingesetzt werden. Eine auf lokaler Gasphasenabscheidung und Mikrostrukturierung mittels der Focused Ion Beam (FIB)-Technik beruhende Sensorfabrikationsmethode wurde gemeinsam mit dem Institut für Mikrotechnologie Hannover (imt) entwickelt. Mehrschichtig mittels CVD und PVD bedampfte und zusätzlich galvanisch beschichtete C-Fasern weisen neuartige Eigenschaften auf, die im vorgestellten Vorhaben am Lehrstuhl für Verbundwerkstoffe (LVW) charakterisiert wurden. Insbesondere die Untersuchung der verschiedenen Schichten sowie deren Interfaces nehmen eine bedeutende Rolle ein.
3

Développement et applications de la tomographie chimique par spectroscopie EDX / Development and applications of chemical tomography by EDX spectroscopy

Lepinay, Kevin 27 November 2013 (has links)
Cette thèse porte sur l’évaluation des techniques pour la tomographie chimique par STEM EDX : mise au point des procédures expérimentales, traitement des données, reconstruction des volumes, analyse de la qualité des résultats obtenus et évaluation de la complexité globale. Les performances très limitées de l’analyse STEM EDX font que peu d’études, jusqu’à aujourd’hui, se sont portées sur cette technique. Cependant, les avancées très notables procurées par les nouveaux détecteurs ‘SDD’ ainsi que les sources électroniques X-FEG haute brillance, rendant l’analyse STEM EDX 2D très rapide, ont relancé la possibilité de la tomographie chimique ; la technique demande toutefois à être mise au point et évaluée (performances et complexité). Nous avons travaillé sur un microscope Tecnai Osiris permettant d’acquérir des cartographies chimiques EDX de centaines de milliers de pixels avec une résolution de l’ordre du nanomètre en quelques minutes. Nous avons choisi de préparer par FIB des échantillons en forme de pointe et d’utiliser un porte-objet permettant une exploration angulaire de 180° sans ombrage. Puis, à l’aide d’échantillons modèles (billes de SiO2 dans une résine), nous avons évalué les déformations d’échantillon par l’irradiation du faisceau électronique. Ceci nous a permis de proposer une méthode pour limiter cet effet par déposition d’une couche de 20 nm de chrome. Des simulations d’images ont permis d’évaluer les logiciels et méthodes de reconstruction. La méthodologie de chaque étape d’une analyse de tomographie STEM EDX a ensuite été expliquée, et l’intérêt de la technique démontré grâce à la comparaison de l’analyse 2D et 3D d’un transistor FDSOI 28 nm. La qualité des reconstructions (rapport signal-sur-bruit, résolution spatiale) a été évaluée en fonction des paramètres expérimentaux à l’aide de simulations et d’expériences. Une résolution de 4 nm est démontrée grâce à l’analyse d’une mire et d’un transistor « gate all around ». Pour ce même transistor, la possibilité et l’intérêt d’analyse de défaillance à l’échelle nanométrique est prouvée. Une analyse d’un défaut de grille d’une SRAM ou de trous dans un pilier en cuivre permettent d’expliquer l’intérêt d’une combinaison d’un volume HAADF (morphologie et résolution < 4 nm) et du volume EDX (information chimique). La conclusion est que cette technique, qui reste encore à améliorer du point de vue de sa simplicité, montre déjà son utilité pour l’analyse et la mise au point des technologies avancées (nœud 20 nm et après). / This thesis focuses on the evaluation of the STEM EDX chemical tomography technique: development of experimental procedures, data processing and volumes reconstruction, quality analysis of the results and evaluation of the overall complexity. Until now, STEM EDX analysis performances were very limited, so only few studies about this technique have been realized. However, very significant progress procured by the new SDD detectors as well as by the high brightness electronic sources (X-FEG), making the STEM EDX 2D analysis very fast, have revived the possibility of the chemical tomography, although the technique has to be developed and evaluated (performance and complexity). We have worked on a Tecnai Osiris which acquires EDX chemical mapping of hundreds of thousands of pixels with resolution of one nanometer and in a few minutes. We chose to prepare the rod-shaped samples by FIB and use a sample holder allowing an angle of exploration of 180° without shadowing effects. Then, using model samples (SiO2 balls in resin), we evaluated the sample deformation due to the electron beam irradiation. This allowed us to propose a method to reduce this effect by depositing a 20 nm chromium layer. Images simulations were used to evaluate the software and the reconstruction methods. The methodology of each step of the STEM EDX tomography analysis is then explained and the technique interest is demonstrated by comparing the 2D and the 3D analysis of a transistor 28 nm FDSOI. The quality of the reconstructions (signal-to-noise ratio, spatial resolution) was evaluated, in function of experimental parameters, using simulations and experiments. A resolution of 4 nm is demonstrated through the analysis of a test pattern and a "gate all around” transistor. For the same transistor, the possibility and the interest of a failure analysis at the nanoscale is proven. Analyses of a SRAM gate fail or of the holes in a copper pillar explain the benefits of a combination between a HAADF volume (morphology and resolution < 4 nm) and an EDX volume (chemical information). To conclude, this technique, which still needs to be improved in terms of simplicity, is already showing its usefulness for the analysis and the development of advanced technologies (20nm node and beyond).
4

3D morphological and crystallographic analysis of materials with a Focused Ion Beam (FIB) / Analyse 3D morphologique et cristallographique des matériaux par microscopie FIB

Yuan, Hui 15 December 2014 (has links)
L’objectif principal de ce travail est d’optimise la tomographie par coupe sériée dans un microscope ‘FIB’, en utilisant soit l’imagerie électronique du microscope à balayage (tomographie FIB-MEB), soit la diffraction des électrons rétrodiffusés (tomographie dite EBSD 3D). Dans les 2 cas, des couches successives de l’objet d’étude sont abrasées à l’aide du faisceau ionique, et les images MEB ou EBSD ainsi acquises séquentiellement sont utilisées pour reconstruire le volume du matériau. A cause de différentes sources de perturbation incontrôlées, des dérives sont généralement présentes durant l'acquisition en tomographie FIB-MEB. Nous avons ainsi développé une procédure in situ de correction des dérives afin de garder automatiquement la zone d'intérêt (ROI) dans le champ de vue. Afin de reconstruction le volume exploré, un alignement post-mortem aussi précis que possible est requis. Les méthodes actuelles utilisant la corrélation-croisée, pour robuste que soit cette technique numérique, présente de sévères limitations car il est difficile, sinon parfois impossible de se fier à une référence absolue. Ceci a été démontré par des expériences spécifiques ; nous proposons ainsi 2 méthodes alternatives qui permettent un bon alignement. Concernant la tomographie EBSD 3D, les difficultés techniques liées au pilotage de la sonde ionique pour l'abrasion précise et au repositionnement géométrique correct de l’échantillon entre les positions d'abrasion et d’EBSD conduisent à une limitation importante de la résolution spatiale avec les systèmes commerciaux (environ 50 nm)3. L’EBSD 3D souffre par ailleurs de limites théoriques (grand volume d'interaction électrons-solide et effets d'abrasion. Une nouvelle approche, qui couple l'imagerie MEB de bonne résolution en basse tension, et la cartographie d'orientation cristalline en EBSD avec des tensions élevées de MEB est proposée. Elle a nécessité le développement de scripts informatiques permettant de piloter à la fois les opérations d’abrasion par FIB et l’acquisition des images MEB et des cartes EBSD. L’intérêt et la faisabilité de notre approche est démontrée sur un cas concret (superalliage de nickel). En dernier lieu, s’agissant de cartographie d’orientation cristalline, une méthode alternative à l’EBSD a été testée, qui repose sur l’influence des effets de canalisation (ions ou électrons) sur les contrastes en imagerie d’électrons secondaires. Cette méthode corrèle à des simulations la variation d’intensité de chaque grain dans une série d’images expérimentales obtenues en inclinant et/ou tournant l’échantillon sous le faisceau primaire. Là encore, la méthode est testée sur un cas réel (polycritsal de TiN) et montre, par comparaison avec une cartographie EBSD, une désorientation maximale d'environ 4° pour les angles d’Euler. Les perspectives d’application de cette approche, potentiellement beaucoup plus rapide que l’EBSD, sont évoquées. / The aim of current work is to optimize the serial-sectioning based tomography in a dual-beam focused ion beam (FIB) microscope, either by imaging in scanning electron microscopy (so-called FIB-SEM tomography), or by electron backscatter diffraction (so-called 3D-EBSD tomography). In both two cases, successive layers of studying object are eroded with the help of ion beam, and sequentially acquired SEM or EBSD images are utilized to reconstruct material volume. Because of different uncontrolled disruptions, drifts are generally presented during the acquisition of FIB-SEM tomography. We have developed thus a live drift correction procedure to keep automatically the region of interest (ROI) in the field of view. For the reconstruction of investigated volume, a highly precise post-mortem alignment is desired. Current methods using the cross-correlation, expected to be robust as this digital technique, show severe limitations as it is difficult, even impossible sometimes to trust an absolute reference. This has been demonstrated by specially-prepared experiments; we suggest therefore two alternative methods, which allow good-quality alignment and lie respectively on obtaining the surface topography by a stereoscopic approach, independent of the acquisition of FIB-SEM tomography, and realisation of a crossed ‘hole’ thanks to the ion beam. As for 3D-EBSD tomography, technical problems, linked to the driving the ion beam for accurate machining and correct geometrical repositioning of the sample between milling and EBSD position, lead to an important limitation of spatial resolution in commercial softwares (~ 50 nm)3. Moreover, 3D EBSD suffers from theoretical limits (large electron-solid interaction volume for EBSD and FIB milling effects), and seems so fastidious because of very long time to implement. A new approach, coupling SEM imaging of good resolution (a few nanometres for X and Y directions) at low SEM voltage and crystal orientation mapping with EBSD at high SEM voltage, is proposed. This method requested the development of computer scripts, which allow to drive the milling of FIB, the acquisition of SEM images and EBSD maps. The interest and feasibility of our approaches are demonstrated by a concrete case (nickel super-alloy). Finally, as regards crystal orientation mapping, an alternative way to EBSD has been tested; which works on the influence of channelling effects (ions or electrons) on the imaging contrast of secondary electrons. This new method correlates the simulations with the intensity variation of each grain within an experimental image series obtained by tilting and/or rotating the sample under the primary beam. This routine is applied again on a real case (polycrystal TiN), and shows a max misorientation of about 4° for Euler angles, compared to an EBSD map. The application perspectives of this approach, potentially faster than EBSD, are also evoked.

Page generated in 0.0561 seconds