1 |
Influência do design de restaurações endocrown em CAD/CAM na carga máxima de carregamento em molares tratados endodonticamenteModena, Cláudia Freitas de Moura January 2015 (has links)
Made available in DSpace on 2016-04-08T03:07:19Z (GMT). No. of bitstreams: 1
000477941-Texto+Parcial-0.pdf: 609 bytes, checksum: 561d326f021051e1a109fba17cc15392 (MD5)
Previous issue date: 2015 / Objectives: To evaluate in vitro the influence of different cavity design preparations for endocrown restorations on the fracture resistance of endodontically treated molars. Materials and methods: Fifty extracted healthy third molars were divided randomly into 5 groups (n= 10 per group): H= healthy, F1= 1 ferrule, F2= 2 ferrules (buccal and palatal), FT= total ferrule and NF= flat plateau. The teeth were submitted to root canal treatment after which the cavity preparations were made. The crowns of endocrown, in Lava Ultimate, were manufactured with the CAD-CAM CEREC/INLAB system and cemented with Single Bond Universal and Rely X Ultimate. The resistance to fracture testing was made in a universal testing machine with a speed of 1mm/min. The pattern of failure was then evaluated, taking into consideration only the presence or absence of fracture in the pulp floor. Results: (Means followed by the same letter do not differ statistically for ANOVA and Tukey): H:3970N ab; F1:3170N ab; F2: 3786N ab; TF: 2894N b; NF:4416N a. The most prevalent pattern of failure was the type recoverable in all groups. Conclusions: The type of cavity preparation for endocrown restoration may influence the fracture resistance of endodontically treated molars. The type of ferrule may determine the greater resistance to loading. The pattern of failure was predominantly recoverable. / Objetivos: avaliar in vitro a influência de diferentes designs de preparos cavitários para restaurações endocrown, na resistência máxima ao carregamento de molares endodonticamente tratados. Materiais e métodos: Cinquenta terceiros molares hígidos e extraídos foram divididos aleatoriamente em 5 grupos (n= 10 por grupo), H= hígido, F1= 1 férula, F2 = 2 férulas VL(vestibular e lingual), FT= férula total e SF= platô reto. Os dentes foram submetidos à endodontia e, após, realizados os preparos cavitários. As coroas de endocrown, em Lava Ultimate, foram confeccionadas através do sistema CAD-CAM CEREC/INLAB e cimentadas com Single Bond Universal e Rely X Ultimate. O ensaio de resistência à fratura foi realizado em uma máquina de ensaios universal com velocidade de 1mm/min até o rompimento do corpo de prova. Após, foi avaliado o padrão de falha o qual levou em consideração apenas a presença ou não de fratura do assoalho pulpar. Resultados: (médias seguidas de mesma letra não apresentam diferença estatística para ANOVA e Tukey): H:3970N AB; F1:3170N AB; F2: 3786N AB; FT 2894N B; SF:4416N A. O padrão de falha predominante foi do tipo fratura da restauração em todos os grupos. Conclusões: o tipo de preparo cavitário para restaurações endocrown pode influenciar na resistência à fratura de molares tratados endodonticamente. O tipo de férula utilizada pode determinar maior resistência ao carregamento. O padrão de falha foi predominantemente recuperável.
|
2 |
Avaliação da resistência à fratura de coroas CAD-CAM sobre pilares sólidosStona, Deborah January 2014 (has links)
Made available in DSpace on 2014-07-19T02:02:56Z (GMT). No. of bitstreams: 1
000459296-Texto+Completo-0.pdf: 283193 bytes, checksum: 3d97b7d2dd51eab591a5bbae03076040 (MD5)
Previous issue date: 2014 / The aim of the study was to evaluate the fracture resistance of ceramic crowns using Cerec CAD-CAM system on solid pillars. Sixty replica synocta implant and RN solid abutment were embedded in acrylic resin, being randomly assigned (n=20 per group). Three types of ceramics were used: Mark II (feldspar), IPS Empress CAD (leucite) and IPS e. max CAD (lithium disilicate). The crowns were fabricated by CAD-CAM system using the Cerec software version 4. 1. After receiving glaze and were cemented with RelyX U200 cement under load of 1 Kg Half of the specimens of each ceramic was subjected to endurance EMIC DL-2000 test fracture in a universal testing machine with a speed of 1 mm / minute and the other half after 1,000,000 cycles of mechanical stress with a load of 100 N. According to two-way ANOVA, the interaction between the material and mechanical cycling was significant (p = 0. 0001). According to Tukey test (α = 5%) the fracture toughness without mechanical cycling and mechanical cycling, respectively, of Mark II (405N/454N) was statistically lower than ceramic IPS Empress CAD (1169N/1240N) and IPS e. max CAD (1378N/1025N) (p < 0. 05). The ceramic IPS Empress CAD and IPS e. max CAD not differ statistically (p > 0. 05). There was no statistical difference in the resistance to cyclic loading with and without fracture to the Mark II and IPS Empress CAD (p > 0. 05, Student's t test) ceramics. For ceramic IPS e. max CAD, the fracture resistance without mechanical cycling was statistically superior to that obtained with cycling (p < 0. 05). The ceramic IPS Empress CAD and IPS e. max CAD showed higher fracture resistance compared to ceramic Mark II. The cyclic loading negatively influenced only IPS e. max CAD. / O objetivo do estudo foi avaliar a resistência à fratura de coroas cerâmicas utilizando o sistema CAD-CAM Cerec sobre pilares sólidos. Sessenta réplicas de implante synocta RN e pilar sólido foram incluídos em resina acrílica autopolimerizável, sendo divididas aleatoriamente (n=20 por grupo). Três tipos de cerâmicas foram utilizadas: Mark II (feldspática), IPS Empress CAD (leucita) e IPS e. max CAD (dissilicato de lítio). As coroas foram confeccionadas através do sistema CAD-CAM utilizando o software Cerec versão 4. 1. Após receberam glaze e foram cimentadas com RelyX U200 sob carga de cimentação de 1 Kg. Metade dos corpos de prova de cada cerâmica foi submetida ao teste de resistência à fratura em máquina de ensaio universal EMIC-DL 2000 com velocidade de 1 mm/minuto e, a outra metade, após 1. 000. 000 de ciclos de fadiga mecânica com carga de 100 N. Segundo ANOVA de duas vias, a interação entre material e ciclagem mecânica foi significativa (p=0,0001). De acordo com o teste de Tukey (α=5%) a resistência à fratura, sem ciclagem mecânica e com ciclagem mecânica respectivamente, da cerâmica Mark II (405N/454N) foi estatisticamente menor que as cerâmicas IPS Empress CAD (1169N/1240N) e IPS e. max CAD (1378N/1025N) (p<0,05). As cerâmicas IPS Empress CAD e IPS e. max CAD não diferiram estatisticamente entre si (p>0,05). Não houve diferença estatística na resistência à fratura sem e com ciclagem mecânica para as cerâmicas Mark II e IPS Empress CAD (p>0,05, teste t-student). Para a cerâmica IPS e. max CAD, a resistência à fratura sem ciclagem mecânica foi estatisticamente superior à obtida com ciclagem (p<0,05). As cerâmicas IPS Empress CAD e IPS e. max CAD apresentaram maior resistência à fratura quando comparadas com a cerâmica Mark II. A ciclagem mecânica influenciou negativamente apenas a cerâmica IPS e. max CAD.
|
3 |
Endocrown em CAD-CAM: análise in vitro da carga máxima de fratura e do modo de falhaSlomp, Cilea January 2015 (has links)
Made available in DSpace on 2015-07-31T02:03:30Z (GMT). No. of bitstreams: 1
000472793-Texto+Completo-0.pdf: 1578702 bytes, checksum: 6981999ba7f8dee786191519497e2438 (MD5)
Previous issue date: 2015 / Objectives : To evaluate the maximum fracture load and the failure pattern of endodontically treated molars restored with endocrown by CAD-CAM system. Methods : Thirty healthy extracted molars were randomly assigned into 3 groups (n=10). After endodontic treatment, teeth were restored with endocrowns by CEREC/InLab (Sirona) system with three different materials: e. max CAD (Ivoclar Vivadent), Vita Mark II (VITA) or Lava Ultimate (3M ESPE). The specimens were subjected to the fractured resistance testing after 1,000,000 cyclic fatigue loading at 100N. Subsequently, they were tested in a universal testing machine with a crosshead speed of 1mm/min with compressive force to the long axis of the tooth. Results : According to a 2-way analysis of variance, the means of fracture resistence were (means followed by the same letter show no significant difference to ANOVA and Tukey) (p <0. 05): Lava Ultimate 3048,6N ± 730. 33 (A), e. max CAD 2188,5N ± 704. 82 (B) and Vita Mark II 1129,5N ± 491. 31 (C). Chi-square test (p = 0. 0342) presented mostly restoration fractures to Vita Mark II (80%), statistically differing from the other groups. Fisher Exact test demonstrated predominantly reparable prognosis to Vita Mark II and unreparable to e. max CAD (p = 0. 0029).Conclusion : Lava Ultimate showed the highest fracture resistance values, while Vita Mark II, the lowest. Vita Mark II group obtained predominantly reparable prognosis. In the other groups, the failure pattern was tooth + restoration with unfavorable prognosis to e. max CAD. / Objetivos : avaliar a carga máxima de fratura e o padrão de falha de restaurações endocrown realizadas com sistema CAD-CAM cimentadas sobre molares tratados endodonticamente. Materiais e métodos : trinta dentes molares hígidos extraídos foram distribuídos aleatoriamente em 3 grupos (n=10). Após serem endodonticamente tratados, foram restaurados com endocrowns realizadas através do sistema CEREC/InLab (Sirona) com três diferentes materiais: e. max CAD (Ivoclar Vivadent), Vita Mark II (VITA) ou Lava Ultimate (3M ESPE). Após, foram submetidos à fadiga mecânica com aplicação de carga vertical de 100N, totalizando 1. 000. 000 de ciclos. Posteriormente, foi testada a carga máxima de fratura com força compressiva ao longo eixo do dente sob velocidade de 1mm/min. Resultados : Os resultados obtidos após o ensaio de carregamento máximo de fratura foram (médias seguidas de mesma letra não apresentam diferença estatística para ANOVA e Tukey) (p<0,05): Lava Ultimate 3048,6N±730,33 (A), e. max CAD 2188,5N±704,82 (B) e Vita Mark II 1129,5N±491,31 (C). Conforme o teste qui-quadrado (p= 0. 0342) o grupo Vita Mark II apresentou a maior proporção para as fraturas somente em restauração (80%), diferindo estatisticamente dos demais grupos. O teste Exato de Fisher evidenciou prognóstico predominantemente recuperável ao Vita Mark II e irrecuperável ao e. max CAD (p= 0,0029).Conclusão : O Lava Ultimate apresentou maior resistência à fratura, enquanto a cerâmica Vita Mark II, a menor. O grupo Vita Mark II apresentou prognóstico predominantemente recuperável. As fraturas nos demais grupos predominaram em dente+restauração, com prognóstico desfavorável ao e. max CAD.
|
4 |
Análise do reparo ósseo nas fraturas de ângulo mandibular com fixação interna rígida: estudo em coelhosWantowski, Gleisse January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:08Z (GMT). No. of bitstreams: 2
000398805-0.pdf: 15997187 bytes, checksum: 0a7222ba3043d12a0e6af43149f8c843 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of the present study was to evaluate, through macroscopic and microscopic analysis the bone repair process in mandibular fractures in rabbits, lineage New Zealand, with especial attention to the titanium plates and screws (Neoortho®), applied as material fixation. For the sample 18 males rabbits were used, with weight maximal to 4000 grams, randomly distributed in three groups, in accordance with the period of observation time. The death of the animals occurred on the 30th, 60th, 90th days. The obtained results demonstrate that, macroscopically the bone fixation system was able to maintain the bone segments in the expected position, without complications associated as healing problems or soft tissue pigmentation. The histological founds may suggest that the fibrous callus is established to the 30 days and the bone callus to the 60 days. The collagen type I, ripe, is predominant in the line of bone repair, especially to the period of 60 days; however the density of the collagen type II is larger. Around the screws the collagen type does not vary accordance with the periods of time. The titanium induces intensive appositional bone growth, without presenting dissolution potential in the soft tissues around the implants surfaces, or complications that indicate a latest removal. The little varied indexes of calcium among the periods of time suggest that established the repair of the fracture, the bone callus is composed by mature bone, which presents a standard mineral density. The system for plates and screws of titanium was shown effective for the treatment of the fractures of mandibular angle in rabbits. / O presente estudo teve por objetivo investigar macroscopicamente e microscopicamente o processo do reparo ósseo no local da fratura mandibular em coelhos da linhagem Nova Zelândia, com atenção às miniplacas e aos parafusos de titânio (Neoortho®), empregados como material de fixação, em diferentes períodos de tempo. Para a amostra foram selecionados 18 coelhos machos da linhagem Nova Zelândia, com peso até 4000 gramas, distribuídos aleatoriamente em três grupos, de acordo com o período de tempo de observação dos animais. Foram efetuadas osteotomias unilaterais em região de ângulo mandibular, fixadas por uma miniplaca e quatro parafusos de titânio. Os animais foram mortos aos 30, 60 e 90 dias. Os resultados obtidos demonstram que, macroscopicamente, o sistema se fixação foi capaz de manter os segmentos ósseos na posição desejada, sem propiciar complicações como processos infecciosos ou pigmentação aos tecidos moles adjacentes. Histologicamente pode-se afirmar que o calo fibroso esteja estabelecido aos 30 dias e o calo ósseo aos 60 dias.O colágeno tipo I, maduro, é predominante na linha de reparo da fratura óssea, especialmente ao período de 60 dias, entretanto a densidade do colágeno tipo II é maior. Em torno das perfurações estes ínices mantem-se proporcionais. O titânio induz ao intenso crescimento ósseo aposicional, sem apresentar potencial de dissolução nos tecidos adjacentes, ou complicações que indiquem sua remoção. Os índices de cálcio pouco variados entre os períodos de tempo sugerem que estabelecido o reparo da fratura, o calo ósseo seja composto por osso corticalizado, de densidade mineral padrão. O sistema por placas e parafusos de titânio se mostrou eficaz para o tratamento das fraturas de ângulo mandibular.
|
5 |
Influência do preparo cavitário e do material restaurador na carga e no tipo de fratura de premolares tratados endodonticamenteSilva, Ana Amélia Bianchi e January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2
000406883-0.pdf: 1791767 bytes, checksum: 2bb90cc0781205c8981e1781f9ba9327 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated the influence of different restoration techniques on the load and type of fracture in endodontically treated pre-molars. Sixty maxillary premolars were divided into the following groups: G1 – healthy; G2 – MOD cavity and direct restoration with Four Season inlay; G3 –MOD cavity and indirect restoration with Adoro inlay; G5 – MOD cavity and restoration with Empress inlay; G4 and G6 – similar to groups 3 and 5, respectively, but with covering the cuspids (onlay). Endodontic treatment was performed in Groups 2 to 6. The specimens were submitted to the compression test in a universal testing machine at a crosshead speed of 0. 5 mm/minute. The type of fracture was classified as follows: Fracture Type I – restricted to the restoration; Fracture Type II – restoration and dental cuspid above the amelocemental junction; Fracture Type III – restoration and dental cuspid below the amelocemental junction; Fracture Type IV – restoration and cuspid below the amelocemental junction with exposure of the pulp chamber; Fracture Type V – along the root. The means of the fracture load values were submitted to Analysis of Variance and the Tukey test, and the results of the fracture type were submitted to the Kruskal-Wallis test at a level of significance of 5%. There was statistically significant difference in the fracture load among the groups (p=0,01). The highest fracture load value was obtained in the group of healthy teeth (1370. 61 N), not differing statistically from the onlay group in Empress (1304. 21 N), both values being statistically higher than those of the other groups. Intermediate values were obtained for the groups inlay in Empress (918. 76 N), onlay in Adoro (861. 15 N) and inlay in Adoro (792. 71 N), which did not differ statistically among them.The lowest fracture load value was obtained for the group with direct restoration with Four Season (666. 08 N) group, which did not differ statistically from the inlay group in Adoro. As regards the type of fracture, there was statistically significant difference among the groups (p=0. 001). The groups onlay in Adoro and healthy teeth did not differ statistically between them, presenting the highest percentage of fractures with the best prognosis (without pulp chamber exposure), and no tooth fractured along the root. Whereas the other experimental groups also did not differ statistically among them, but all presented fractures extending along the root (the worst prognosis). / Este trabalho avaliou a influência de diferentes técnicas restauradoras na carga e no tipo de fratura em premolares tratados endodonticamente. Sessenta premolares superiores foram divididos nos seguintes grupos: G1 – hígidos; G2 – cavidade MOD e restauração direta com Four Season tipo inlay; G3 – cavidade MOD e restauração indireta com Adoro tipo inlay; G5 – cavidade MOD e restauração com Empress tipo inlay; G4 e G6 – semelhantes aos grupos 3 e 5, respectivamente, mas com cobertura de cúspides (tipo onlay). Foi realizada endodontia nos grupos 2 a 6. Os corpos-de-prova foram submetidos ao ensaio de compressão em máquina de ensaio universal com velocidade de 0,5 mm/minuto. O tipo de fratura foi classificado da seguinte forma: fratura tipo I – restrita à restauração; fratura tipo II – restauração e cúspide dentária acima da junção amelocementária; fratura tipo III – restauração e cúspide dentária abaixo da junção amelocementária; fratura tipo IV – restauração e cúspide abaixo da junção amelocementária com exposição da câmara pulpar; fratura tipo V – ao longo da raiz. As médias dos valores de carga de fratura foram submetidos à Análise de Variância e Teste de Tukey, e os resultados do tipo de fratura foram submetidos ao teste Kruskal-Wallis ao nível de significância foi de 5%.Houve diferença estatisticamente significante na carga de fratura entre os grupos (p=0,01). O maior valor de carga de fratura foi obtido no grupo dos dentes hígidos (1370,61 N), não diferindo estatisticamente do grupo onlay em Empress (1304,21 N), sendo ambos os valores estatisticamente superiores aos demais grupos. Valores intermediários foram obtidos para os grupos inlay em Empress (918,76 N), onlay em Adoro (861,15 N) e inlay em Adoro (792,71 N), os quais não diferiram estatisticamente entre si. O menor valor de carga de fratura foi obtido para o grupo da restauração direta com Four Season (666,08 N), não diferindo estatisticamente do grupo inlay em Adoro. Também houve diferença estatística significativa para o tipo de fratura entre os grupos (p=0,001). Os grupos onlay em Adoro e hígidos não diferiram estatisticamente entre si, apresentando maior porcentagem de fraturas com melhor prognóstico (sem exposição da câmara pulpar), e nenhum dente com fratura ao longo da raiz. Já os demais grupos experimentais também não diferiram estatisticamente entre si, mas todos apresentaram fraturas se estendendo ao longo da raiz (pior prognóstico).
|
6 |
Influência de cimentos resinosos autoadesivos na deflexão de cúspides e carga de fratura de pré-molares restaurados com inlays em resina compostaSalaverry, Aurélio January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2
000431091-0.pdf: 6484611 bytes, checksum: ee0b40e71498d6a5f8496211522ca10f (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the influence of four resin cements (one conventional and three self-adhesive) on cuspal deflection, fracture load and failure mode of endodontically treated teeth restored with composite resin inlays. Seventy-two maxillary premolars were randomly divided into four groups: G1 - sound teeth (control); G2 - cavities without restoration; G3 - RelyX ARC; G4 - RelyX U100; G5 - Maxcem Elite; G6 - SeT. The teeth from groups 2, 3, 4, 5 and 6 received mesio-occlusal-distal preparations and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4, 5 and 6. Inlays with Z350 XT composite resin were built over each cast and luted with the resin cements. After storage in water at 37o C for 72 hours, a 200-N load was applied on the occlusal face using an 8 mm diameter metal sphere, and the cuspal deflection was measured using a micrometer. Following, the specimens were submitted to 500,000 cycles of mechanical fatigue, and the cuspal deflection was measured again. The specimens were then submitted to an axial load until failure. According to Kruskal-Wallis, group 2 (69 μm) had the highest cuspal deflection before mechanical fatigue, and did not differ statistically from group 6 (51 μm). Group 1 (4 μm), group 3 (4 μm) and group 4 (5 μm) obtained the lowest cuspal deflections, and did not differ between them. Intermediate value was obtained for group 5 (21 μm), and this group did not differ statistically from groups 3, 4 and 6. According to Wilcoxon test, there was no statistically difference between the cuspal deflection before and after mechanical fatigue only for group 3 (p=0,015). According to Kruskal- Wallis, group 1 (1902 N) had the highest fracture load, and differed statistically from the other groups. The second highest value was obtained for group 3 (980,8 N), and differed statistically from the other groups. Group 4 (670,6 N), group 5 (533,5 N), group 6 (601,3 N) and group 2 (526,6 N) did not differ between them. There was a predominance of recovery fractures for the restored groups. Composite resin inlays luted with RelyX ARC kept the cuspal deflection stability, obtained higher strength of the teeth, as well as fractures with good prognosis for rehabilitation. / O objetivo desse estudo foi avaliar a influência de quatro cimentos resinosos (um convencional e três autoadesivos) na deflexão de cúspides, carga de fratura e tipos de fratura de pré-molares com acesso endodôntico e restaurados com inlays em resina composta. Setenta e dois primeiros pré-molares foram divididos aleatoriamente em seis grupos (n=12): G1 (controle) - hígidos; G2 – cavidades sem restauração; G3 –RelyX ARC; G4 –RelyX U100; G5- Maxcem Elite; G6 –SeT. Os Grupos 2-6 receberam preparos cavitários MOD e acesso endodôntico. Os grupos 3-6 foram moldados com silicona por adição e vazados com gesso especial para confecção de inlays em resina composta Z350 XT. As restaurações indiretas foram cimentadas nas respectivas cavidades com carga de 1 Kg e fotoativadas. Após armazenagem em água destilada a 37º C por 72 horas, carga de 200 N foi aplicada na região oclusal com uma esfera de 8 mm de diâmetro acoplada na máquina de ensaio universal EMIC DL 2000, sendo medida a deflexão de cúspides com um micrômetro digital. Os corpos de prova foram então submetidos a 500. 000 ciclos de fadiga mecânica, e novo teste de deflexão de cúspides foi realizado. Em seguida, os corpos de prova foram submetidos ao ensaio de compressão até a fratura na máquina de ensaio universal. De acordo com o teste de Kruskal-Wallis, a maior deflexão de cúspides pré-fadiga foi obtida para o grupo 2 (69 μm), não diferindo estatisticamente do grupo 6 (51 μm). As menores deflexões de cúspides foram obtidas para o grupo 1 (4 μm), o grupo 3 (4 μm) e o grupo 4 (5 μm), os quais não diferiram estatisticamente entre si. Valor intermediário foi obtido para o grupo 5 (21 μm), não diferindo estatisticamente dos grupos 3, 4 e 6. De acordo com o teste de Wilcoxon, não houve diferença estatística entre a deflexão de cúspides pré e pós-fadiga apenas para o grupo 3 (p=0,015). De acordo com Kruskal-Wallis, a maior carga de fratura foi obtida para o grupo 1 (1902 N), diferindo estatisticamente dos outros grupos. Segundo maior valor foi obtido para o grupo 3 (980,8 N), diferindo estatisticamente dos outros grupos. Grupo 4 (670,6 N), grupo 5 (533,5 N), grupo 6 (601,3 N) e grupo 2 (526,6 N) não diferiram estatisticamente entre si. Para os grupos restaurados, houve predominância de fraturas recuperáveis. Inlays em resina composta cimentadas com RelyX ARC mantiveram a estabilidade da deflexão de cúspides, proporcionaram maior recuperação da resistência da estrutura dentária, assim como fraturas mais favoráveis para a reabilitação.
|
7 |
Resistência à fratura de dentes com preparos cavitários MOD restaurados com resina composta e fibra de vidroRodrigues, Fausto Borges January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2
000392253-0.pdf: 813004 bytes, checksum: 92cc239906e68f814913bc5491cecb54 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate in vitro the effect of two types of glass fibers, unidirectional or woven, placed inside of MOD cavity preparations on fracture strength of endodontically treated molars, either restored with composite resin, or not. Ninety sound human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to six groups (n=15). Group 1 G1 (sound teeth), control. Groups G2, G3, G4, G5 e G6 were subjected to the following procedures: G2 – MOD cavity preparation; G3 – MOD and endodontic treatment (ET); G4 –MOD + ET + composite resin restoration (CR); G5 – MOD + ET + unidirectional fiber (UF) + CR; G6 - MOD + ET + woven fiber (WF) + CR. The specimens were stored in physiological serum at 37oC for 24 hours. Later, a compressive force was applied by means of a universal testing machine at 1 mm/min speed, parallel to the long axis of the teeth until the fracture occurred. After mechanical test three types of fractures were classified: 1) pulp chamber floor; 2) cusp; 3) pulp chamber floor and cusp. The means of results (N) followed by the same letter do not represent a statistical difference by ANOVA and Tukey (p<0,05): G1 (4960)a, G2 (1926. 20)b, G3 (612. 84)c, G4(1813. 9)b, G5 (2024)b, G6 (1879)b. In the analysis of qualitative variables of G5 and G6, there was a tendency to fracture in the pulp chamber floor and cusp not benefic to restore the tooth integrity. It is possible conclude that inserting the unidirectional or woven glass fibers into MOD cavity preparations and restored with composite resin the fracture strength is similar to that obtained in molars filled with composite resin only. / A proposta deste estudo foi avaliar o efeito de dois tipos de fibras, uma trançada e outra unidirecional, inseridas no interior de cavidades MOD padronizadas na resistência à fratura de dentes molares tratados endodonticamente. Noventa dentes terceiros molares hígidos foram selecionados e montados em blocos acrílicos, sendo estes divididos em seis grupos de quinze (n=15). No grupo G1, os dentes mantiveram-se hígidos (controle). Os grupos G2, G3, G4, G5 e G6 receberam preparos cavitários MOD padronizados, sendo que nos grupos G3, G4, G5 e G6 foram realizados tratamentos endodônticos. Após o preparo dos dentes, estes foram restaurados com resina composta, no grupo G4, e no grupo G5 e G6 foram inseridas dois tipos de fibras, uma trançada e outra unidirecional, respectivamente. Após, os corpos de prova foram submetidos ao ensaio de resistência à fratura. Avaliou-se, também, qualitativamente as falhas classificando-as em fratura de cúspide, assoalho e cúspide mais assoalho, após o ensaio mecânico. Os resultados (N) obtidos foram (médias seguidas de mesma letra não apresentam diferença estatística para Anova e Tukey (p<0,05): Grupo G1 (4960)a, Grupo G2 (1926,20)b, Grupo G3 (612,84)c, Grupo G4 (1813,9)b, Grupo G5 (2024)b, Grupo G6 (1879)b. Conclui-se que a utilização de fibras trançadas ou unidirecionais no interior de cavidades MOD de dentes com tratamento endodôntico não melhora a resistência a compressão apresentando um padrão de fratura de assoalho mais cúspide não favorável à recuperação da peça dentária.
|
Page generated in 0.0271 seconds