• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 4
  • Tagged with
  • 10
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resistência à fadiga flexural dos sistemas rotatórios k3 e Endosequence em razão do uso / Resistance to flexural fatigue of K3 and Endosequence rotary systems in relation to the use

Brisighello, Luis Cesar 30 October 2008 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica de dois diferentes sistemas rotatórios de níquel-titânio, K3 (Sybron Endo, EUA) e Endosequence (Brasseler, EUA), fundamentando-se no número de usos. Todas as limas rotatórias que foram selecionadas possuíam conicidade 0.04, 25 mm de comprimento e diâmetro de ponta 25, padrão ISO. Para tal logro, um dispositivo desenvolvido especificamente para executar ensaios dinâmicos foi utilizado. Cada grupo foi subdividido em quatro subgrupos em função do número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso; grupos A1 e B1, instrumentos de um único uso; grupos A3 e B3, instrumentos de três usos e grupos A5 e B5, instrumentos de cinco usos. Cada subgrupo era composto por 12 limas, totalizando 96 instrumentos rotatórios entre K3 e Endosequence. A simulação foi realizada em canais artificiais de resina com curvatura de 40 graus e raio de 5 mm. Todas as limas foram submetidas a ensaios de fadiga cíclica realizados em um dispositivo experimental que permitiu que o instrumento reproduzisse uma instrumentação rotatória em canais curvos. Esse dispositivo possui um temporizador, que registra o tempo de avanços em segundos, desde o início do movimento até a fratura da lima e também um contador, que registra dentro do intervalo de tempo o número de ciclos realizados pelo cilindro pneumático até o momento da fratura. Foi utilizada uma peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 350 rpm e 2 Ncm de torque. O tempo foi registrado por meio do contador presente no dispositivo. Os valores foram transformados em segundos. Para análise estatística, empregou-se o teste de análise de variância (dois critérios) entre as amostras testadas e observou-se que não houve diferença estatisticamente significante em relação ao número de usos. Entretanto, o sistema K3 apresentou maior resistência à fadiga flexural em relação ao sistema Endosequence (p < 0,05). / The aim of this work was to evaluate the cyclic fatigue resistance of two different nickel-titanium rotary systems, K3 (Sybron Endo, EUA) and Endosequence (Brasseler, EUA), based on the number of uses. All rotary files which were selected had their conicity of 0,04, 25mm of length and tip diameter of 25, following ISO standardization. To reach the purposes, a specially developed apparatus to perform dynamic assays was employed. Each group was subdivided into 4 subgroups according to the number of uses, being established as follows: groups A0 and B0, instruments without any use; groups A1 and B1, instruments of a single use; groups A3 and B3, instruments of three uses and groups A5 and B5, instruments of five uses. Each subgroup was compound of 12 files, totalizing 96 rotary instruments between K3 and Endosequence. The simulation was conducted in resin artificial canals presenting curvature of 40 degrees and radius of 5 mm. All files were submitted to cyclic fatigue assays performed on an experimental apparatus where the instrument could reproduce a rotary instrumentation in curved canals. This equipment contains an timer, which records advance time per seconds, since the begin of movement until the file fracture, and also has a counter which registers, on a period of time, the cycle number accomplished by the pneumatic cylinder until the fracture time. A reducer contra-angle hand piece of 16:1 was used, activated by an electric motor on a speed of 350rpm and 2 Ncm of torque. Time was recorded by the counter coupled in the apparatus. Values were converted into seconds. The two-way analysis of variance was employed to statistical evaluation, among tested samples and we could observe that no statistical differences were found in relation to the number of uses. However, the K3 system showed higher resistance to flexural fatigue when compared to the Endosequence system (p < 0,01).
2

Resistência à fadiga flexural dos sistemas rotatórios k3 e Endosequence em razão do uso / Resistance to flexural fatigue of K3 and Endosequence rotary systems in relation to the use

Luis Cesar Brisighello 30 October 2008 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica de dois diferentes sistemas rotatórios de níquel-titânio, K3 (Sybron Endo, EUA) e Endosequence (Brasseler, EUA), fundamentando-se no número de usos. Todas as limas rotatórias que foram selecionadas possuíam conicidade 0.04, 25 mm de comprimento e diâmetro de ponta 25, padrão ISO. Para tal logro, um dispositivo desenvolvido especificamente para executar ensaios dinâmicos foi utilizado. Cada grupo foi subdividido em quatro subgrupos em função do número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso; grupos A1 e B1, instrumentos de um único uso; grupos A3 e B3, instrumentos de três usos e grupos A5 e B5, instrumentos de cinco usos. Cada subgrupo era composto por 12 limas, totalizando 96 instrumentos rotatórios entre K3 e Endosequence. A simulação foi realizada em canais artificiais de resina com curvatura de 40 graus e raio de 5 mm. Todas as limas foram submetidas a ensaios de fadiga cíclica realizados em um dispositivo experimental que permitiu que o instrumento reproduzisse uma instrumentação rotatória em canais curvos. Esse dispositivo possui um temporizador, que registra o tempo de avanços em segundos, desde o início do movimento até a fratura da lima e também um contador, que registra dentro do intervalo de tempo o número de ciclos realizados pelo cilindro pneumático até o momento da fratura. Foi utilizada uma peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 350 rpm e 2 Ncm de torque. O tempo foi registrado por meio do contador presente no dispositivo. Os valores foram transformados em segundos. Para análise estatística, empregou-se o teste de análise de variância (dois critérios) entre as amostras testadas e observou-se que não houve diferença estatisticamente significante em relação ao número de usos. Entretanto, o sistema K3 apresentou maior resistência à fadiga flexural em relação ao sistema Endosequence (p < 0,05). / The aim of this work was to evaluate the cyclic fatigue resistance of two different nickel-titanium rotary systems, K3 (Sybron Endo, EUA) and Endosequence (Brasseler, EUA), based on the number of uses. All rotary files which were selected had their conicity of 0,04, 25mm of length and tip diameter of 25, following ISO standardization. To reach the purposes, a specially developed apparatus to perform dynamic assays was employed. Each group was subdivided into 4 subgroups according to the number of uses, being established as follows: groups A0 and B0, instruments without any use; groups A1 and B1, instruments of a single use; groups A3 and B3, instruments of three uses and groups A5 and B5, instruments of five uses. Each subgroup was compound of 12 files, totalizing 96 rotary instruments between K3 and Endosequence. The simulation was conducted in resin artificial canals presenting curvature of 40 degrees and radius of 5 mm. All files were submitted to cyclic fatigue assays performed on an experimental apparatus where the instrument could reproduce a rotary instrumentation in curved canals. This equipment contains an timer, which records advance time per seconds, since the begin of movement until the file fracture, and also has a counter which registers, on a period of time, the cycle number accomplished by the pneumatic cylinder until the fracture time. A reducer contra-angle hand piece of 16:1 was used, activated by an electric motor on a speed of 350rpm and 2 Ncm of torque. Time was recorded by the counter coupled in the apparatus. Values were converted into seconds. The two-way analysis of variance was employed to statistical evaluation, among tested samples and we could observe that no statistical differences were found in relation to the number of uses. However, the K3 system showed higher resistance to flexural fatigue when compared to the Endosequence system (p < 0,01).
3

Fadiga cíclica flexural de instrumentos Hyflex CM e TF Adaptive em diferentes situações experimentais / Flexural cyclic fatigue of instruments Hyflex CM and TF Adaptive in diferente experimental situations

Mustafá, Nágila Ali 08 March 2016 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel- titânio, Hyflex CM (Coltène, EUA) e TF Adaptive (SybronEndo, EUA) em diferentes situações experimentais. Todas as limas que foram selecionadas possuíam conicidade 0,04 e diâmetro de ponta 35. Utilizou-se um dispositivo desenvolvido especificamente para realizar o ensaio flexural dinâmico. Os instrumentos TF Adaptive foram divididos em 3 grupos de acordo com o ângulo de curvatura do ensaio: 45º, 60º e 90º e cada grupo subdividido em 2 subgrupos de acordo com o tipo de movimento: rotação contínua e Adaptive. Cada subgrupo era composto por 15 instrumentos TF Adaptive, totalizando 90 instrumentos. Quinze instrumentos Hyflex CM formavam o grupo 4, no ensaio com ângulo de curvatura 90 graus e rotação contínua. A simulação foi realizada em canais artificiais de aço com ângulo de 45, 60, 90 graus e raio 5m m. O número de ciclos e o tempo em segundos até a fratura foram tabulados e analisados. Entretanto, a fadiga cíclica flexural foi significante maior nos três grupos em movimento Adaptive. E as limas TF Adaptive em seu próprio movimento tiveram maior número de ciclos e tempo até a fratura quando comparadas as Hyflex CM no ensaio de 90 graus. Portanto, conclui-se que o sistema Adaptive (limas TF Adaptive + movimento Adaptive) foi mais seguro à resistência á fadiga flexural, e no ensaio de 90 graus o sistema Adaptive foi mais resistente quando comparado com as limas Hyflex CM no movimento de rotação contínua. / The aim of this work to evaluate the cyclic fatigue resistance flexural the instruments of nickel-titanium, HyFlex CM (Coltène, USA) and TF Adaptive (SybronEndo, USA) in different experimental situations. All files that were selected had 0.04 taper and tip diameter 35. We used a device developed specifically to perform the dynamic flexural test. The TF Adaptive instruments were divided into 3 groups according to the angle of curvature of the test: 45, 60 and 90 and further divided in two subgroups according to the type of movement: continuous rotation and Adaptive. Each group consisted of 15 instruments TF Adaptive totaling 90 instruments. Fifteen HyFlex CM instruments formed the group 4 in the trial of bend angle 90 degrees and continuous rotation. The simulation was performed in artificial steel angled channels 45, 60, 90 degrees and radius 5m m. The number of cycles and the time in seconds until fracture were tabulated and analyzed. However, the cyclical flexural fatigue was significantly greater in the three groups Adaptive motion. And the TF Adaptive files on your own movement had a higher number of cycles and time to fracture when the HyFlex CM compared in 90-degree test. Therefore, it is concluded that the adaptive system (TF Adaptive Motion + Adaptive files) was safer resistance to flexural fatigue, and 90 degrees test Adaptive system is more resistant when compared with the HyFlex files into continuous.
4

Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varredura

Renan Diego Furlan 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
5

Avaliação da resistência à fadiga cíclica flexural dos instrumentos Reciproc Blue e WaveOne Gold / Evaluation of cyclic flexural fatigue of Reciproc Blue and WaveOne Gold instruments

Poveda, Leonardo Medina 04 July 2017 (has links)
Inquestionavelmente, inovações ocorridas nos últimos anos no preparo do canal radicular revolucionaram o tratamento endodôntico. Dentre elas, destaca-se o tratamento térmico recristalizador da liga de níquel-titânio na confecção de limas endodônticas, o qual aumentou de sobremaneira sua flexibilidade e as capacidades de flexibilidade, torção e resistência à fadiga cíclica flexural quando comparadas às limas de níquel-titânio convencionais fabricadas até então. O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel-titânio tratados termicamente Reciproc Blue R25 (VDW) e WaveOne Gold Primary (Dentsply-Maillefer) em um dispositivo desenvolvido especificamente para realizar ensaios flexurais dinâmicos. As limas selecionadas possuíam conicidade 0,08 mm e 0,07 mm respectivamente, com diâmetros de ponta 0,25 mm e foram utilizadas no motor elétrico VDW Silver Reciproc (VDW) em movimento reciprocante específico de cada sistema. Os instrumentos foram divididos em 2 grupos de 15 limas e testados em canais de aço simulados com o ângulo de 60º e raio de curvatura de 5mm. O número de ciclos e o tempo em segundos até a ocorrência de fratura dos instrumentos foram registrados e estatisticamente avaliados. As limas Reciproc Blue R25 apresentaram desempenho significativamente melhor (P<0,05), por meio do maior número de ciclos e de tempo até a fratura quando comparadas com as limas WaveOne Gold. Assim, conclui-se que o sistema Reciproc Blue R25 foi mais seguro quanto à resistência à fadiga flexural no ensaio realizado quando comparado ao sistema WaveOne Gold Primary em movimento reciprocante. / Innovations that have occurred in recent years in the preparation of the root canal have revolutionized endodontic treatment. Among them, the heat treatment of the nickel-titanium alloy in the manufacture of endodontic files, which greatly increased the flexibility, torsional and flexural fatigue resistance capacities when compared to the conventional nickel-titanium files manufactured until then. The present study aimed to evaluate the resistance to flexural cyclic fatigue of thermally treated Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply-Maillefer) instruments in a device specifically developed to perform dynamic flexural tests. The selected files had taper 0.08 mm and 0.07 mm respectively, with tip diameters of 0.25 mm and were used in the reciprocating movement of each system in the VDW Silver Reciproc (VDW) electric motor. The instruments were divided into 2 groups of 15 files and tested in simulated steel channels with angle of 60º and radius of curvature of 5mm. The number of cycles and the time in seconds until the occurrence of fracture of the instruments were recorded and statistically evaluated. The Reciproc Blue R25 files presented significantly better performance (p <0.05), by the higher number of cycles and time to fracture when compared to WaveOne Gold files. Thus, it was concluded that the Reciproc Blue R25 system was safer than the WaveOne Gold Primary reciprocating system in terms of resistence of flexural fatigue
6

Fadiga cíclica flexural de instrumentos Hyflex CM e TF Adaptive em diferentes situações experimentais / Flexural cyclic fatigue of instruments Hyflex CM and TF Adaptive in diferente experimental situations

Nágila Ali Mustafá 08 March 2016 (has links)
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel- titânio, Hyflex CM (Coltène, EUA) e TF Adaptive (SybronEndo, EUA) em diferentes situações experimentais. Todas as limas que foram selecionadas possuíam conicidade 0,04 e diâmetro de ponta 35. Utilizou-se um dispositivo desenvolvido especificamente para realizar o ensaio flexural dinâmico. Os instrumentos TF Adaptive foram divididos em 3 grupos de acordo com o ângulo de curvatura do ensaio: 45º, 60º e 90º e cada grupo subdividido em 2 subgrupos de acordo com o tipo de movimento: rotação contínua e Adaptive. Cada subgrupo era composto por 15 instrumentos TF Adaptive, totalizando 90 instrumentos. Quinze instrumentos Hyflex CM formavam o grupo 4, no ensaio com ângulo de curvatura 90 graus e rotação contínua. A simulação foi realizada em canais artificiais de aço com ângulo de 45, 60, 90 graus e raio 5m m. O número de ciclos e o tempo em segundos até a fratura foram tabulados e analisados. Entretanto, a fadiga cíclica flexural foi significante maior nos três grupos em movimento Adaptive. E as limas TF Adaptive em seu próprio movimento tiveram maior número de ciclos e tempo até a fratura quando comparadas as Hyflex CM no ensaio de 90 graus. Portanto, conclui-se que o sistema Adaptive (limas TF Adaptive + movimento Adaptive) foi mais seguro à resistência á fadiga flexural, e no ensaio de 90 graus o sistema Adaptive foi mais resistente quando comparado com as limas Hyflex CM no movimento de rotação contínua. / The aim of this work to evaluate the cyclic fatigue resistance flexural the instruments of nickel-titanium, HyFlex CM (Coltène, USA) and TF Adaptive (SybronEndo, USA) in different experimental situations. All files that were selected had 0.04 taper and tip diameter 35. We used a device developed specifically to perform the dynamic flexural test. The TF Adaptive instruments were divided into 3 groups according to the angle of curvature of the test: 45, 60 and 90 and further divided in two subgroups according to the type of movement: continuous rotation and Adaptive. Each group consisted of 15 instruments TF Adaptive totaling 90 instruments. Fifteen HyFlex CM instruments formed the group 4 in the trial of bend angle 90 degrees and continuous rotation. The simulation was performed in artificial steel angled channels 45, 60, 90 degrees and radius 5m m. The number of cycles and the time in seconds until fracture were tabulated and analyzed. However, the cyclical flexural fatigue was significantly greater in the three groups Adaptive motion. And the TF Adaptive files on your own movement had a higher number of cycles and time to fracture when the HyFlex CM compared in 90-degree test. Therefore, it is concluded that the adaptive system (TF Adaptive Motion + Adaptive files) was safer resistance to flexural fatigue, and 90 degrees test Adaptive system is more resistant when compared with the HyFlex files into continuous.
7

Avaliação da resistência à fadiga cíclica flexural dos instrumentos Reciproc Blue e WaveOne Gold / Evaluation of cyclic flexural fatigue of Reciproc Blue and WaveOne Gold instruments

Leonardo Medina Poveda 04 July 2017 (has links)
Inquestionavelmente, inovações ocorridas nos últimos anos no preparo do canal radicular revolucionaram o tratamento endodôntico. Dentre elas, destaca-se o tratamento térmico recristalizador da liga de níquel-titânio na confecção de limas endodônticas, o qual aumentou de sobremaneira sua flexibilidade e as capacidades de flexibilidade, torção e resistência à fadiga cíclica flexural quando comparadas às limas de níquel-titânio convencionais fabricadas até então. O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel-titânio tratados termicamente Reciproc Blue R25 (VDW) e WaveOne Gold Primary (Dentsply-Maillefer) em um dispositivo desenvolvido especificamente para realizar ensaios flexurais dinâmicos. As limas selecionadas possuíam conicidade 0,08 mm e 0,07 mm respectivamente, com diâmetros de ponta 0,25 mm e foram utilizadas no motor elétrico VDW Silver Reciproc (VDW) em movimento reciprocante específico de cada sistema. Os instrumentos foram divididos em 2 grupos de 15 limas e testados em canais de aço simulados com o ângulo de 60º e raio de curvatura de 5mm. O número de ciclos e o tempo em segundos até a ocorrência de fratura dos instrumentos foram registrados e estatisticamente avaliados. As limas Reciproc Blue R25 apresentaram desempenho significativamente melhor (P<0,05), por meio do maior número de ciclos e de tempo até a fratura quando comparadas com as limas WaveOne Gold. Assim, conclui-se que o sistema Reciproc Blue R25 foi mais seguro quanto à resistência à fadiga flexural no ensaio realizado quando comparado ao sistema WaveOne Gold Primary em movimento reciprocante. / Innovations that have occurred in recent years in the preparation of the root canal have revolutionized endodontic treatment. Among them, the heat treatment of the nickel-titanium alloy in the manufacture of endodontic files, which greatly increased the flexibility, torsional and flexural fatigue resistance capacities when compared to the conventional nickel-titanium files manufactured until then. The present study aimed to evaluate the resistance to flexural cyclic fatigue of thermally treated Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply-Maillefer) instruments in a device specifically developed to perform dynamic flexural tests. The selected files had taper 0.08 mm and 0.07 mm respectively, with tip diameters of 0.25 mm and were used in the reciprocating movement of each system in the VDW Silver Reciproc (VDW) electric motor. The instruments were divided into 2 groups of 15 files and tested in simulated steel channels with angle of 60º and radius of curvature of 5mm. The number of cycles and the time in seconds until the occurrence of fracture of the instruments were recorded and statistically evaluated. The Reciproc Blue R25 files presented significantly better performance (p <0.05), by the higher number of cycles and time to fracture when compared to WaveOne Gold files. Thus, it was concluded that the Reciproc Blue R25 system was safer than the WaveOne Gold Primary reciprocating system in terms of resistence of flexural fatigue
8

Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varredura

Furlan, Renan Diego 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
9

Comparison of the mechanical properties of engine-driven nickel- titanium instruments manufactured by different thermal treatments / Comparação das propriedades mecânicas de instrumentos mecanizados de níquel-titânio fabricados com diferentes tratamentos térmicos

Alcalde, Murilo Priori 03 April 2018 (has links)
The aim of this study was to evaluate the mechanical properties of engine-driven Nickel-Titanium instruments manufactured by different thermal treatments. In the first part of this study, 60 reciprocating instruments were used (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). The cyclic flexural fatigue resistance was performed measuring the time to failure in an artificial stainless steel canal with a 60º angle and a 5 mm radius of curvature (n=10). The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion (n=10). Additionally, the fractured surface of each instrument was examined by scanning electron microscopy (SEM) to assess the topographic features of the fractured surface. Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). REC 25.08 showed higher fatigue resistance than UNC 25.06 (P<0.05). In relation to the torsional test, the PDR 25.06 presented the lowest torque load than REC 25.08 and UNC 25.06 (P<0.05). In addition, there was no significant difference between REC 25.08 and UNC 25.06 (P>0.05). The PDR 25.06 and UNC 25.06 showed higher angular rotation until fracture than REC 25.08 (P<0.05). No difference was found between PDR 25.06 and UNC 25.06. All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The second part of this study evaluated the cyclic flexural and torsional fatigue resistance of reciprocating instruments Reciproc Blue (RB 25.08), WaveOne Gold Primary (WOG 25.07) and Prodesign R 25 (PDR 25.06) (n=20). The cyclic flexural fatigue test was performed with the same previsoly described device, using a root curvature with 60º and a 5 mm radius (n=10) and the torsional test was performed according to ISO 3630-1 (n=10). The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue test showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P<0.05). The torsional test showed that PDR 25.06 had lowed torsional load (P<0.05). No difference was found between RB 25.08 and WOG 25.07 (P>0.05). In relation the angular rotation, the PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P<0.05). RB 25.08 presented higher angular values than WOG 25.07 (P<0.05). All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The third part of this study was to evaluate the torsional fatigue resistance of NiTi rotary glide path instruments. The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion. A total of 56 glide path instruments were used (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01(LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) and Mtwo 10.04. The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results showed that LOG 25.01 had a significantly higher torsional load than the other groups (P<0.05). The PGD 16.02 had significantly difference in comparison with HGPF 15.01 and 15.02 (P<0.05). LOG CM 25.01 had higher torsional load than HGPF 15.01 and 15.02 (P<0.05). No difference was found among Mtwo 10.04, HGPG 15.01, 15.02 and 20.02. In relation the angular rotation, LOG CM 25.01 and HGPF 15.01 presented the highest values (P<0.05). PGD 16.02 had the lowest values (P<0.05) followed by Mtwo 10.04. LOG 25.01 had higher angle of rotation than PGD 16.02 and Mtwo 10.04 (P<0.05). All the instruments showed typical topographic features of torsional fatigue. / O objetivo deste estudo foi avaliar o comportamento mecânico de instrumentos mecanizados de Níquel-Titânio (NiTi) fabricados com diferentes tratamentos térmicos. Na primeira parte do estudo foram utilizados 60 instrumentos reciprocantes para a realização dos teste de fadiga cíclica flexural e torcional (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). O teste de fadiga cíclica flexural foi realizado com o objetivo de mensurar o tempo para a fratura dos instrumentos em um canal artificial de aço inoxidável com curvatura com 60º de angulação e 5 mm de raio (n=10). Para o teste de torção, os 3 mm inicias das pontas dos instrumentos foram fixadas em um aparelho de torção (n=10), de acordo com a norma ISO 3630-1. Este teste foi realizado com o objetivo de mensurar o torque máximo e o ângulo de rotação suportado pelos instrumentos até sua fratura. Adicionalmente, todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou maior tempo para a fratura do que os outros grupos (P<0.05). O instrumento REC 25.08 apresentou maior resistência a fadiga cíclica flexural do que o UNC 25.06 (P<0.05). O teste de torção demonstrou que o PDR 25.06 apresentou significantemente menor resistência torcional do que o REC 25.08 e UNC 25.06 (P<0.05). Além disso, não houve diferença entre REC 25.08 e UNC 25.06. Com relação ao ângulo de rotação, o PDR 25.06 e UNC 25.06 apresentaram diferença significante quando comparado ao REC 25.08. Não houve diferença entre PDR 25.06 e UNC 25.06 (P>0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga cíclica flexural e torcional. Na segunda parte deste estudo avaliou-se a fadiga cíclica flexural e torcional dos instrumentos reciprocantes Reciproc Blue R25 (RB 25.08), WaveOne Gold Primary (WOG 25.07) e Prodesign R 25 (PDR 25.06) (n=20). O teste de fadiga cíclica flexural foi realizado com dispositivo descrito anteriormente, utilizando curvaturas de 60º e 5 mm de raio (n=10). O teste de torção foi realizado de acordo com a norma ISO 3630-1 (n=10). Todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator (ANOVA) e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou a maior resistência a fadiga cíclica flexural do que dos outros grupos (P<0.05). O RB 25.08 apresentou maior tempo para à fratura do que o WOG 25.07 (P<0.05). O teste de torção, o PDR 25.06 apresentou a menor resistência à torção do que os outros grupos (P<0.05). Não houve diferença significante entre RB 25.08 e WOG 25.07 (P>0.05). Em relação ao ângulo de rotação, o PDR 25.06 apresentou maiores valores quando comparados com RB 25.08 e WOG 25.07. O RB 25.08 apresentou diferença significante quando comparado com WOG 25.07. Todos os instrumentos apresentaram características topográficas típicas de fadiga cíclica flexural e torcional. Na terceira parte deste estudo avaliou-se a resistência torcional de instrumentos empregados para patência do canal radicular, de acordo com a norma ISO 3630-1. Foram utilizados 56 instrumentos rotatórios (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01 (LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) e Mtwo 10.04. Os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados demonstraram que o LOG 25.01 apresentou significantemente maior resistência torcional do que os demais grupos (P<0.05). O grupo da PGD 16.02 apresentou diferença significante quando comparado com HGPF 15.01 e 15.02 (P<0.05). O LOG CM 25.01 apresentou maior resistência torcional do que o grupo do HGPF 15.01 e 15.02 (P<0.05). Não houve diferença significante entre os intrumentos Mtwo 10.04 e HGPF 15.01, 15.02 e 20.02. Com relação ao ângulo de rotação, o LOG CM 25.01 e HGPF 15.01 apresentaram os maiores valores (P<0.05). O PGD 16.02 apresentou o menor valor de todos os grupos (P<0.05) seguido pelo Mtwo 10.04. O LOG 25.01 apresentou maiores ângulos de rotação do que o PGD 16.02 e Mtwo 10.04 (P<0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga torcional. As características da secção transversal, tipo de núcleo, taper e o tratamento térmico possuem forte influência sobre as propriedades mecânicas dos instrumentos de NiTi. No entanto, o tratamento térmico é um dos fatores primordiais para maior flexibilidade dos instrumentos. O instrumento PDR 25.06 apresentou maior resistência à fadiga cíclica flexural e maior ângulo de rotação no teste de torção do que todos os outros instrumentos reciprocantes avaliados. No entanto, menor resistência torcional. Os intrumentos LOG 25.01 apresentaram maior resistência torcional e o LOG CM 25.01 maiores ângulos de rotação.
10

Comparison of the mechanical properties of engine-driven nickel- titanium instruments manufactured by different thermal treatments / Comparação das propriedades mecânicas de instrumentos mecanizados de níquel-titânio fabricados com diferentes tratamentos térmicos

Murilo Priori Alcalde 03 April 2018 (has links)
The aim of this study was to evaluate the mechanical properties of engine-driven Nickel-Titanium instruments manufactured by different thermal treatments. In the first part of this study, 60 reciprocating instruments were used (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). The cyclic flexural fatigue resistance was performed measuring the time to failure in an artificial stainless steel canal with a 60º angle and a 5 mm radius of curvature (n=10). The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion (n=10). Additionally, the fractured surface of each instrument was examined by scanning electron microscopy (SEM) to assess the topographic features of the fractured surface. Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). REC 25.08 showed higher fatigue resistance than UNC 25.06 (P<0.05). In relation to the torsional test, the PDR 25.06 presented the lowest torque load than REC 25.08 and UNC 25.06 (P<0.05). In addition, there was no significant difference between REC 25.08 and UNC 25.06 (P>0.05). The PDR 25.06 and UNC 25.06 showed higher angular rotation until fracture than REC 25.08 (P<0.05). No difference was found between PDR 25.06 and UNC 25.06. All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The second part of this study evaluated the cyclic flexural and torsional fatigue resistance of reciprocating instruments Reciproc Blue (RB 25.08), WaveOne Gold Primary (WOG 25.07) and Prodesign R 25 (PDR 25.06) (n=20). The cyclic flexural fatigue test was performed with the same previsoly described device, using a root curvature with 60º and a 5 mm radius (n=10) and the torsional test was performed according to ISO 3630-1 (n=10). The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue test showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P<0.05). The torsional test showed that PDR 25.06 had lowed torsional load (P<0.05). No difference was found between RB 25.08 and WOG 25.07 (P>0.05). In relation the angular rotation, the PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P<0.05). RB 25.08 presented higher angular values than WOG 25.07 (P<0.05). All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The third part of this study was to evaluate the torsional fatigue resistance of NiTi rotary glide path instruments. The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion. A total of 56 glide path instruments were used (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01(LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) and Mtwo 10.04. The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results showed that LOG 25.01 had a significantly higher torsional load than the other groups (P<0.05). The PGD 16.02 had significantly difference in comparison with HGPF 15.01 and 15.02 (P<0.05). LOG CM 25.01 had higher torsional load than HGPF 15.01 and 15.02 (P<0.05). No difference was found among Mtwo 10.04, HGPG 15.01, 15.02 and 20.02. In relation the angular rotation, LOG CM 25.01 and HGPF 15.01 presented the highest values (P<0.05). PGD 16.02 had the lowest values (P<0.05) followed by Mtwo 10.04. LOG 25.01 had higher angle of rotation than PGD 16.02 and Mtwo 10.04 (P<0.05). All the instruments showed typical topographic features of torsional fatigue. / O objetivo deste estudo foi avaliar o comportamento mecânico de instrumentos mecanizados de Níquel-Titânio (NiTi) fabricados com diferentes tratamentos térmicos. Na primeira parte do estudo foram utilizados 60 instrumentos reciprocantes para a realização dos teste de fadiga cíclica flexural e torcional (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). O teste de fadiga cíclica flexural foi realizado com o objetivo de mensurar o tempo para a fratura dos instrumentos em um canal artificial de aço inoxidável com curvatura com 60º de angulação e 5 mm de raio (n=10). Para o teste de torção, os 3 mm inicias das pontas dos instrumentos foram fixadas em um aparelho de torção (n=10), de acordo com a norma ISO 3630-1. Este teste foi realizado com o objetivo de mensurar o torque máximo e o ângulo de rotação suportado pelos instrumentos até sua fratura. Adicionalmente, todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou maior tempo para a fratura do que os outros grupos (P<0.05). O instrumento REC 25.08 apresentou maior resistência a fadiga cíclica flexural do que o UNC 25.06 (P<0.05). O teste de torção demonstrou que o PDR 25.06 apresentou significantemente menor resistência torcional do que o REC 25.08 e UNC 25.06 (P<0.05). Além disso, não houve diferença entre REC 25.08 e UNC 25.06. Com relação ao ângulo de rotação, o PDR 25.06 e UNC 25.06 apresentaram diferença significante quando comparado ao REC 25.08. Não houve diferença entre PDR 25.06 e UNC 25.06 (P>0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga cíclica flexural e torcional. Na segunda parte deste estudo avaliou-se a fadiga cíclica flexural e torcional dos instrumentos reciprocantes Reciproc Blue R25 (RB 25.08), WaveOne Gold Primary (WOG 25.07) e Prodesign R 25 (PDR 25.06) (n=20). O teste de fadiga cíclica flexural foi realizado com dispositivo descrito anteriormente, utilizando curvaturas de 60º e 5 mm de raio (n=10). O teste de torção foi realizado de acordo com a norma ISO 3630-1 (n=10). Todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator (ANOVA) e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou a maior resistência a fadiga cíclica flexural do que dos outros grupos (P<0.05). O RB 25.08 apresentou maior tempo para à fratura do que o WOG 25.07 (P<0.05). O teste de torção, o PDR 25.06 apresentou a menor resistência à torção do que os outros grupos (P<0.05). Não houve diferença significante entre RB 25.08 e WOG 25.07 (P>0.05). Em relação ao ângulo de rotação, o PDR 25.06 apresentou maiores valores quando comparados com RB 25.08 e WOG 25.07. O RB 25.08 apresentou diferença significante quando comparado com WOG 25.07. Todos os instrumentos apresentaram características topográficas típicas de fadiga cíclica flexural e torcional. Na terceira parte deste estudo avaliou-se a resistência torcional de instrumentos empregados para patência do canal radicular, de acordo com a norma ISO 3630-1. Foram utilizados 56 instrumentos rotatórios (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01 (LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) e Mtwo 10.04. Os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados demonstraram que o LOG 25.01 apresentou significantemente maior resistência torcional do que os demais grupos (P<0.05). O grupo da PGD 16.02 apresentou diferença significante quando comparado com HGPF 15.01 e 15.02 (P<0.05). O LOG CM 25.01 apresentou maior resistência torcional do que o grupo do HGPF 15.01 e 15.02 (P<0.05). Não houve diferença significante entre os intrumentos Mtwo 10.04 e HGPF 15.01, 15.02 e 20.02. Com relação ao ângulo de rotação, o LOG CM 25.01 e HGPF 15.01 apresentaram os maiores valores (P<0.05). O PGD 16.02 apresentou o menor valor de todos os grupos (P<0.05) seguido pelo Mtwo 10.04. O LOG 25.01 apresentou maiores ângulos de rotação do que o PGD 16.02 e Mtwo 10.04 (P<0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga torcional. As características da secção transversal, tipo de núcleo, taper e o tratamento térmico possuem forte influência sobre as propriedades mecânicas dos instrumentos de NiTi. No entanto, o tratamento térmico é um dos fatores primordiais para maior flexibilidade dos instrumentos. O instrumento PDR 25.06 apresentou maior resistência à fadiga cíclica flexural e maior ângulo de rotação no teste de torção do que todos os outros instrumentos reciprocantes avaliados. No entanto, menor resistência torcional. Os intrumentos LOG 25.01 apresentaram maior resistência torcional e o LOG CM 25.01 maiores ângulos de rotação.

Page generated in 0.0471 seconds