Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varredura

Renan Diego Furlan 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
2

Kitkaväsyminen akselien kutistusliitoksissa

Juuma, T. (Teuvo) 01 October 2001 (has links)
Abstract Fretting is present where the contacting surfaces of mechanical parts are subjected to rubbing and an alternating stress, resulting in fatigue in the material. This is the situation between the hub and shaft in a shrink-fitted assembly. In practice, fretting is found in the same assembly with normal fatigue, and it occurs in the axle in a shrink-fit between an axle and a hub, while normal fatigue cracks are found outside the assembly. Fretting phenomena have been investigated by many authors in laboratories, but the dimensioning criteria for shrink-fit assemblies are insufficient for the construction engineer. Fretting causes a considerable reduction in the fatigue strength of a shrink-fit assembly, and failures caused by fretting are as numerous as failures resulting from normal fatigue. The purpose of this investigation was to examine the effect of hub material, contact pressure, slip amplitude and shaft geometry on fatigue strength. The goal of this investigation was to determine an optimal contact pressure and a favourable fillet radius and axle diameter ratio at which fretting failure can be avoided and maximum normal fatigue strength will be obtained. The torsional fatigue strength of shrink-fitted shaft couplings was estimated using tests that varied the material of the hub, the contact pressure, the geometry of the shaft and the torsional stress amplitude of the shrink-fitted assembly. Based on the information obtained from the test, aluminium as a hub material appears to produce little damage to a steel shaft, whereas bronze appears to cause damage and fatigue. Cast iron and steel caused a medium amount of damage. To increase contact pressure at the shoulder, hub overhang past the shoulder was used. These experiments showed that increasing the contact pressure decreased the slip amplitude, thereby reducing fretting. With low contact pressure, shaft fracturing began from fretting fatigue inside the hub, but with high contact pressure the shaft fractured at the fillet due to normal fatigue. Selecting the fillet radius according to the contact pressure makes it possible to dimension the shrink-fit shaft assembly to prevent fretting. The shrink-fitted shaft should be designed according to the normal fatigue limit, because fretting fatigue may occur when the number of load cycles exceeds 2×107. Fretting can be prevented by using a sufficiently high contact pressure and by choosing optimal ratios for the fillet radius and the diameter. To avoid fretting, the slip amplitude should be under 3 μm. This is achieved by using a contact pressure of over 100 N/mm2, calculated according to Lamé's theory. A method for dimensioning a shrink-fitted shaft with respect to fretting fatigue was presented based on a specific geometry (Ø 50 mm) and the materials used in the tests. The method was applied in verifying the fretting fatigue of a shrink-fitted shaft with a diameter of 300 mm. / Tiivistelmä Kitkaväsyminen esiintyy yleisesti, kun koneenosien kontaktipintoihin kohdistuu edestakainen jännitysamplitudi hankaavan liikkeen lisäksi johtaen materiaalin väsymiseen. Tällainen tilanne vallitsee navan ja akselin välissä kutistusliitoksessa. Kitkaväsyminen esiintyy käytännössä samassa kutistusliitoksessa kuin normaali väsyminenkin ja se ilmenee navan ja akselin välissä yleensä akselissa, kun taas tavanomainen väsyminen tapahtuu akselissa liitoksen ulkopuolella. Kitkaväsymistä on tutkittu paljonkin, mutta kutistusliitoksen mitoituskriteerit kitkaväsymisen osalta ovat puutteelliset. Kitkaväsyminen aiheuttaa merkittävän väsymislujuuden heikkenemisen sekä täten väsymisiän alenemisen kutistusliitoksessa ja sen aiheuttamat vauriot ovat määrältään samaa luokkaa tavanomaisen väsymisen kanssa. Tämän tutkimuksen tarkoituksena oli selvittää napamateriaalin, liitospaineen, liukuma-amplitudin ja geometrian vaikutus väsymislujuuteen. Tavoitteena oli määrittää optimaalinen liitospaine sekä sopivat olakkeen pyöristyssäde ja akselisuhde, jotta kitkaväsyminen voidaan välttää ja saavuttaa maksimaalinen normaali väsymislujuus. Kitkaväsymislujuutta väännön suhteen testattiin varioimalla napamateriaalia, liitospainetta, geometriaa ja jännitysamplitudia. Testien perusteella alumiininen napamateriaali sopi hyvin teräsakselin kanssa, kun taas pronssi aiheutti akseliin pintavaurion ja sitä kautta väsymisilmiön. Teräs- ja valurautanapa olivat näiden kahden materiaalin välissä. Liitospaineen nostamiseksi olakkeen reunalla käytettiin navan ylitystä olakkeen yli. Kokeet osoittivat kitkaväsymisen vähenevän korkeammilla liitospaineilla liukuman aletessa. Alhaisella liitospaineella akselin vaurioituminen alkoi kitkaväsymisenä navan sisältä, mutta hyvin korkealla liitospaineella murtuminen tapahtui olakkeesta tavanomaisena väsymisenä. Valitsemalla pyöristyssäde liitospaineen perusteella kutistusliitos on mitoitettavissa kitkaväsymistä vastaan. Kutistusliitos tulisi mitoittaa tavanomaisen väsymisen mukaan, koska kitkaväsymismurtuma voi tapahtua kuormanvaihtoluvulla yli 2×07. Kitkaväsyminen on ehkäistävissä käyttämällä riittävän korkeata liitospainetta sekä sopivaa olakkeen pyöristyssädettä yhdistyneenä oikeaan akselisuhteeseen. Kitkaväsyminen estyy kun liukuma-amplitudi on alle 3 μm. Tämä on saavutettavissa liitospaineella yli 100 N/mm2 laskettuna Lamén teorian mukaan. Tutkimuksessa on esitetty mitoitusmenetelmä kitkaväsymisen suhteen perustuen Ø 50 mm akselilla sekä käytetyillä materiaaleilla tehtyihin testeihin. Menetelmää on sovellettu kitkaväsymisen tarkasteluun kutistusliitokseen, jonka akselin halkaisija on 300 mm.
3

Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varredura

Furlan, Renan Diego 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
4

An Energy-Based Experimental-Analytical Torsional Fatigue Life-Prediction Method

Wertz, John Nicholas 02 September 2010 (has links)
No description available.
5

Comparison of the mechanical properties of engine-driven nickel- titanium instruments manufactured by different thermal treatments / Comparação das propriedades mecânicas de instrumentos mecanizados de níquel-titânio fabricados com diferentes tratamentos térmicos

Alcalde, Murilo Priori 03 April 2018 (has links)
The aim of this study was to evaluate the mechanical properties of engine-driven Nickel-Titanium instruments manufactured by different thermal treatments. In the first part of this study, 60 reciprocating instruments were used (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). The cyclic flexural fatigue resistance was performed measuring the time to failure in an artificial stainless steel canal with a 60º angle and a 5 mm radius of curvature (n=10). The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion (n=10). Additionally, the fractured surface of each instrument was examined by scanning electron microscopy (SEM) to assess the topographic features of the fractured surface. Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). REC 25.08 showed higher fatigue resistance than UNC 25.06 (P<0.05). In relation to the torsional test, the PDR 25.06 presented the lowest torque load than REC 25.08 and UNC 25.06 (P<0.05). In addition, there was no significant difference between REC 25.08 and UNC 25.06 (P>0.05). The PDR 25.06 and UNC 25.06 showed higher angular rotation until fracture than REC 25.08 (P<0.05). No difference was found between PDR 25.06 and UNC 25.06. All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The second part of this study evaluated the cyclic flexural and torsional fatigue resistance of reciprocating instruments Reciproc Blue (RB 25.08), WaveOne Gold Primary (WOG 25.07) and Prodesign R 25 (PDR 25.06) (n=20). The cyclic flexural fatigue test was performed with the same previsoly described device, using a root curvature with 60º and a 5 mm radius (n=10) and the torsional test was performed according to ISO 3630-1 (n=10). The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue test showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P<0.05). The torsional test showed that PDR 25.06 had lowed torsional load (P<0.05). No difference was found between RB 25.08 and WOG 25.07 (P>0.05). In relation the angular rotation, the PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P<0.05). RB 25.08 presented higher angular values than WOG 25.07 (P<0.05). All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The third part of this study was to evaluate the torsional fatigue resistance of NiTi rotary glide path instruments. The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion. A total of 56 glide path instruments were used (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01(LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) and Mtwo 10.04. The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results showed that LOG 25.01 had a significantly higher torsional load than the other groups (P<0.05). The PGD 16.02 had significantly difference in comparison with HGPF 15.01 and 15.02 (P<0.05). LOG CM 25.01 had higher torsional load than HGPF 15.01 and 15.02 (P<0.05). No difference was found among Mtwo 10.04, HGPG 15.01, 15.02 and 20.02. In relation the angular rotation, LOG CM 25.01 and HGPF 15.01 presented the highest values (P<0.05). PGD 16.02 had the lowest values (P<0.05) followed by Mtwo 10.04. LOG 25.01 had higher angle of rotation than PGD 16.02 and Mtwo 10.04 (P<0.05). All the instruments showed typical topographic features of torsional fatigue. / O objetivo deste estudo foi avaliar o comportamento mecânico de instrumentos mecanizados de Níquel-Titânio (NiTi) fabricados com diferentes tratamentos térmicos. Na primeira parte do estudo foram utilizados 60 instrumentos reciprocantes para a realização dos teste de fadiga cíclica flexural e torcional (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). O teste de fadiga cíclica flexural foi realizado com o objetivo de mensurar o tempo para a fratura dos instrumentos em um canal artificial de aço inoxidável com curvatura com 60º de angulação e 5 mm de raio (n=10). Para o teste de torção, os 3 mm inicias das pontas dos instrumentos foram fixadas em um aparelho de torção (n=10), de acordo com a norma ISO 3630-1. Este teste foi realizado com o objetivo de mensurar o torque máximo e o ângulo de rotação suportado pelos instrumentos até sua fratura. Adicionalmente, todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou maior tempo para a fratura do que os outros grupos (P<0.05). O instrumento REC 25.08 apresentou maior resistência a fadiga cíclica flexural do que o UNC 25.06 (P<0.05). O teste de torção demonstrou que o PDR 25.06 apresentou significantemente menor resistência torcional do que o REC 25.08 e UNC 25.06 (P<0.05). Além disso, não houve diferença entre REC 25.08 e UNC 25.06. Com relação ao ângulo de rotação, o PDR 25.06 e UNC 25.06 apresentaram diferença significante quando comparado ao REC 25.08. Não houve diferença entre PDR 25.06 e UNC 25.06 (P>0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga cíclica flexural e torcional. Na segunda parte deste estudo avaliou-se a fadiga cíclica flexural e torcional dos instrumentos reciprocantes Reciproc Blue R25 (RB 25.08), WaveOne Gold Primary (WOG 25.07) e Prodesign R 25 (PDR 25.06) (n=20). O teste de fadiga cíclica flexural foi realizado com dispositivo descrito anteriormente, utilizando curvaturas de 60º e 5 mm de raio (n=10). O teste de torção foi realizado de acordo com a norma ISO 3630-1 (n=10). Todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator (ANOVA) e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou a maior resistência a fadiga cíclica flexural do que dos outros grupos (P<0.05). O RB 25.08 apresentou maior tempo para à fratura do que o WOG 25.07 (P<0.05). O teste de torção, o PDR 25.06 apresentou a menor resistência à torção do que os outros grupos (P<0.05). Não houve diferença significante entre RB 25.08 e WOG 25.07 (P>0.05). Em relação ao ângulo de rotação, o PDR 25.06 apresentou maiores valores quando comparados com RB 25.08 e WOG 25.07. O RB 25.08 apresentou diferença significante quando comparado com WOG 25.07. Todos os instrumentos apresentaram características topográficas típicas de fadiga cíclica flexural e torcional. Na terceira parte deste estudo avaliou-se a resistência torcional de instrumentos empregados para patência do canal radicular, de acordo com a norma ISO 3630-1. Foram utilizados 56 instrumentos rotatórios (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01 (LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) e Mtwo 10.04. Os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados demonstraram que o LOG 25.01 apresentou significantemente maior resistência torcional do que os demais grupos (P<0.05). O grupo da PGD 16.02 apresentou diferença significante quando comparado com HGPF 15.01 e 15.02 (P<0.05). O LOG CM 25.01 apresentou maior resistência torcional do que o grupo do HGPF 15.01 e 15.02 (P<0.05). Não houve diferença significante entre os intrumentos Mtwo 10.04 e HGPF 15.01, 15.02 e 20.02. Com relação ao ângulo de rotação, o LOG CM 25.01 e HGPF 15.01 apresentaram os maiores valores (P<0.05). O PGD 16.02 apresentou o menor valor de todos os grupos (P<0.05) seguido pelo Mtwo 10.04. O LOG 25.01 apresentou maiores ângulos de rotação do que o PGD 16.02 e Mtwo 10.04 (P<0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga torcional. As características da secção transversal, tipo de núcleo, taper e o tratamento térmico possuem forte influência sobre as propriedades mecânicas dos instrumentos de NiTi. No entanto, o tratamento térmico é um dos fatores primordiais para maior flexibilidade dos instrumentos. O instrumento PDR 25.06 apresentou maior resistência à fadiga cíclica flexural e maior ângulo de rotação no teste de torção do que todos os outros instrumentos reciprocantes avaliados. No entanto, menor resistência torcional. Os intrumentos LOG 25.01 apresentaram maior resistência torcional e o LOG CM 25.01 maiores ângulos de rotação.
6

Comparison of the mechanical properties of engine-driven nickel- titanium instruments manufactured by different thermal treatments / Comparação das propriedades mecânicas de instrumentos mecanizados de níquel-titânio fabricados com diferentes tratamentos térmicos

Murilo Priori Alcalde 03 April 2018 (has links)
The aim of this study was to evaluate the mechanical properties of engine-driven Nickel-Titanium instruments manufactured by different thermal treatments. In the first part of this study, 60 reciprocating instruments were used (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). The cyclic flexural fatigue resistance was performed measuring the time to failure in an artificial stainless steel canal with a 60º angle and a 5 mm radius of curvature (n=10). The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion (n=10). Additionally, the fractured surface of each instrument was examined by scanning electron microscopy (SEM) to assess the topographic features of the fractured surface. Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). REC 25.08 showed higher fatigue resistance than UNC 25.06 (P<0.05). In relation to the torsional test, the PDR 25.06 presented the lowest torque load than REC 25.08 and UNC 25.06 (P<0.05). In addition, there was no significant difference between REC 25.08 and UNC 25.06 (P>0.05). The PDR 25.06 and UNC 25.06 showed higher angular rotation until fracture than REC 25.08 (P<0.05). No difference was found between PDR 25.06 and UNC 25.06. All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The second part of this study evaluated the cyclic flexural and torsional fatigue resistance of reciprocating instruments Reciproc Blue (RB 25.08), WaveOne Gold Primary (WOG 25.07) and Prodesign R 25 (PDR 25.06) (n=20). The cyclic flexural fatigue test was performed with the same previsoly described device, using a root curvature with 60º and a 5 mm radius (n=10) and the torsional test was performed according to ISO 3630-1 (n=10). The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue test showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P<0.05). The torsional test showed that PDR 25.06 had lowed torsional load (P<0.05). No difference was found between RB 25.08 and WOG 25.07 (P>0.05). In relation the angular rotation, the PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P<0.05). RB 25.08 presented higher angular values than WOG 25.07 (P<0.05). All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The third part of this study was to evaluate the torsional fatigue resistance of NiTi rotary glide path instruments. The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion. A total of 56 glide path instruments were used (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01(LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) and Mtwo 10.04. The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results showed that LOG 25.01 had a significantly higher torsional load than the other groups (P<0.05). The PGD 16.02 had significantly difference in comparison with HGPF 15.01 and 15.02 (P<0.05). LOG CM 25.01 had higher torsional load than HGPF 15.01 and 15.02 (P<0.05). No difference was found among Mtwo 10.04, HGPG 15.01, 15.02 and 20.02. In relation the angular rotation, LOG CM 25.01 and HGPF 15.01 presented the highest values (P<0.05). PGD 16.02 had the lowest values (P<0.05) followed by Mtwo 10.04. LOG 25.01 had higher angle of rotation than PGD 16.02 and Mtwo 10.04 (P<0.05). All the instruments showed typical topographic features of torsional fatigue. / O objetivo deste estudo foi avaliar o comportamento mecânico de instrumentos mecanizados de Níquel-Titânio (NiTi) fabricados com diferentes tratamentos térmicos. Na primeira parte do estudo foram utilizados 60 instrumentos reciprocantes para a realização dos teste de fadiga cíclica flexural e torcional (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). O teste de fadiga cíclica flexural foi realizado com o objetivo de mensurar o tempo para a fratura dos instrumentos em um canal artificial de aço inoxidável com curvatura com 60º de angulação e 5 mm de raio (n=10). Para o teste de torção, os 3 mm inicias das pontas dos instrumentos foram fixadas em um aparelho de torção (n=10), de acordo com a norma ISO 3630-1. Este teste foi realizado com o objetivo de mensurar o torque máximo e o ângulo de rotação suportado pelos instrumentos até sua fratura. Adicionalmente, todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou maior tempo para a fratura do que os outros grupos (P<0.05). O instrumento REC 25.08 apresentou maior resistência a fadiga cíclica flexural do que o UNC 25.06 (P<0.05). O teste de torção demonstrou que o PDR 25.06 apresentou significantemente menor resistência torcional do que o REC 25.08 e UNC 25.06 (P<0.05). Além disso, não houve diferença entre REC 25.08 e UNC 25.06. Com relação ao ângulo de rotação, o PDR 25.06 e UNC 25.06 apresentaram diferença significante quando comparado ao REC 25.08. Não houve diferença entre PDR 25.06 e UNC 25.06 (P>0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga cíclica flexural e torcional. Na segunda parte deste estudo avaliou-se a fadiga cíclica flexural e torcional dos instrumentos reciprocantes Reciproc Blue R25 (RB 25.08), WaveOne Gold Primary (WOG 25.07) e Prodesign R 25 (PDR 25.06) (n=20). O teste de fadiga cíclica flexural foi realizado com dispositivo descrito anteriormente, utilizando curvaturas de 60º e 5 mm de raio (n=10). O teste de torção foi realizado de acordo com a norma ISO 3630-1 (n=10). Todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator (ANOVA) e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou a maior resistência a fadiga cíclica flexural do que dos outros grupos (P<0.05). O RB 25.08 apresentou maior tempo para à fratura do que o WOG 25.07 (P<0.05). O teste de torção, o PDR 25.06 apresentou a menor resistência à torção do que os outros grupos (P<0.05). Não houve diferença significante entre RB 25.08 e WOG 25.07 (P>0.05). Em relação ao ângulo de rotação, o PDR 25.06 apresentou maiores valores quando comparados com RB 25.08 e WOG 25.07. O RB 25.08 apresentou diferença significante quando comparado com WOG 25.07. Todos os instrumentos apresentaram características topográficas típicas de fadiga cíclica flexural e torcional. Na terceira parte deste estudo avaliou-se a resistência torcional de instrumentos empregados para patência do canal radicular, de acordo com a norma ISO 3630-1. Foram utilizados 56 instrumentos rotatórios (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01 (LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) e Mtwo 10.04. Os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados demonstraram que o LOG 25.01 apresentou significantemente maior resistência torcional do que os demais grupos (P<0.05). O grupo da PGD 16.02 apresentou diferença significante quando comparado com HGPF 15.01 e 15.02 (P<0.05). O LOG CM 25.01 apresentou maior resistência torcional do que o grupo do HGPF 15.01 e 15.02 (P<0.05). Não houve diferença significante entre os intrumentos Mtwo 10.04 e HGPF 15.01, 15.02 e 20.02. Com relação ao ângulo de rotação, o LOG CM 25.01 e HGPF 15.01 apresentaram os maiores valores (P<0.05). O PGD 16.02 apresentou o menor valor de todos os grupos (P<0.05) seguido pelo Mtwo 10.04. O LOG 25.01 apresentou maiores ângulos de rotação do que o PGD 16.02 e Mtwo 10.04 (P<0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga torcional. As características da secção transversal, tipo de núcleo, taper e o tratamento térmico possuem forte influência sobre as propriedades mecânicas dos instrumentos de NiTi. No entanto, o tratamento térmico é um dos fatores primordiais para maior flexibilidade dos instrumentos. O instrumento PDR 25.06 apresentou maior resistência à fadiga cíclica flexural e maior ângulo de rotação no teste de torção do que todos os outros instrumentos reciprocantes avaliados. No entanto, menor resistência torcional. Os intrumentos LOG 25.01 apresentaram maior resistência torcional e o LOG CM 25.01 maiores ângulos de rotação.