• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 339
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 357
  • 357
  • 351
  • 342
  • 291
  • 286
  • 280
  • 272
  • 71
  • 58
  • 53
  • 46
  • 45
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Tomografia computadorizada por feixe cônico para detecção de lesões incipientes de furca simuladas em mandíbulas suínas maceradas / Cone beam computed tomography for detection of incipient furcation invasion in pig mandibles

Otávio Shoiti Umetsubo 04 July 2011 (has links)
As radiografias intraorais ilustram bem os estágios de reabsorção periodontal nas regiões interproximais. Entretanto, a sobreposição de estruturas dificulta avaliação da perda óssea nas corticais vestibular e lingual. A tomografia computadorizada por feixe cônico (TCFC) é de elevada importância em várias especialidades odontológicas, tais como implantodontia, avaliação de lesões ósseas, estudo da articulação têmporo-mandibular e cirurgia buco-maxilo-facial. A TCFC também tem tido crescente indicação em outras áreas, como a periodontia e endodontia. O objetivo no presente estudo foi a) estabelecer o protocolo de aquisição mais adequado para a detecção de lesões incipientes de furca simuladas quimicamente; e b) avaliar a reprodutibilidade, sensibilidade e especificidade da TCFC, para a finalidade previamente citada. No presente estudo, foram utilizadas 15 mandíbulas suínas maceradas, que apresentavam o segundo molar íntegro e as corticais adjacentes preservadas As simulações de lesões em região de furca foram feitas com aplicação de ácido perclórico a 70%, em até quatro sítios possíveis em cada mandíbula (vestibular do lado direito, lingual do lado direito, vestibular do lado esquerdo, lingual do lado esquerdo) por um examinador participante que não avaliou as imagens. Nos 60 sitios possíveis, foram escolhidos aleatoriamente 20 para as simulações das lesões. Posteriormente, as mandíbulas foram submetidas à TCFC (i-CAT Next Generation) em dois. protocolos de aquição: voxel 0,2 mm e 0,25 mm, ambos com FOV de 6 cm de altura por 16 cm de diâmetro e com 26,9 segundos de tempo. Dois observadores (radiologistas previamente calibrados) avaliaram os exames duas vezes, em ordem aleatória, sob iluminação controlada. Os observadores foram orientados a direcionar a avaliação das regiões dos segundos molares, e questionados se havia lesão ou não nos sítios avaliados. A interpretação das imagens foi realizada em uma estação de trabalho independente localizada no Laboratório de Imagem em Terceira Dimensão da Faculdade de Odontologia da Universidade de São Paulo, utilizando o software Xoran (Xoran Technologies). A sensibilidade, especificidade e reprodutibilidade da TCFC foram avaliadas nos dois protocolos. A TCFC apresentou especificidade alta, sensibilidade baixa e reprodutibilidade moderada na detecção de lesões incipientes de furca. A influência do tamanho do voxel não foi estatisticamente significativa na detecção destas lesões. / Intraoral radiographs illustrate the stages of resorption in periodontal interproximal regions. However, overlapping structures hinders evaluation of bone loss in the buccal and lingual cortical plates. The cone beam computed tomography (CBCT) is of high importance in various dental specialties such as implantology, evaluation of bone lesions, the study of temporomandibular joint and maxillo-facial surgery. The CBCT has also been increasing indications in other areas, such as periodontics and endodontics. The aim of this study was to establish a) the acquisition protocol most suitable for the detection of incipient furcation invasion chemically simulated and b) assess the reproducibility, sensitivity and specificity of CBCT for the purpose previously mentioned. In this study, 15 pigs macerated mandibles were used, which showed the second molar and the adjacent cortical integrity preserved. Simulated lesions in the furcation area were made with application of 70% perchloric acid, up to four possible sites in each jaw (the right buccal, the right lingual, the left buccal, and left lingual side) by an examiner participant who did not evaluate the images. In the 60 possible sites, 20 were randomly chosen for the simulated lesions. Subsequently, the mandibles underwent cone beam computed tomography (Next Generation i-CAT) in two acquisition protocols: at 0.2 mm and 0.25 mm voxel, both with FOV of 6 cm height by 16 cm in diameter and 26.9 seconds of time. Two observers (calibrated radiologists) evaluated the examinations twice, in random order under controlled lighting. Observers were instructed to direct the evaluation to the regions of the second molars, and they were asked if there were or not injuries on those avaluated sites. Image interpretation was performed on an independent workstation located at the Third Dimension Laboratory of Image in the School of Dentistry, University of São Paulo, using the software Xoran (Xoran Technologies). The sensitivity, specificity and reproducibility of CBCT were assessed in both trials. The CBCT showed high specificity, low sensitivity and moderate reproducibility in the detection of incipient lesions, furcation. The influence of voxel size was not statistically significant in detecting these lesions.
62

Foraminas acessórias da região anterior da maxila em tomografia computadorizada de feixe cônico / Additional foraminas in anterior maxilla through cone beam computed tomography

Ikuta, Carla Renata Sanomiya 27 October 2017 (has links)
Por meio do exame tridimensional de Tomografia computadorizada de feixe cônico (TCFC) é possível avaliar a área de interesse previamente aos procedimentos com maior precisão. As variações anatômicas são estruturas que devem ser consideradas para a realização de cirurgias, como a foramina acessória da região anterior da maxila (FARAM). O objetivo principal do presente estudo foi avaliar a FARAM, em 150 exames de TCFC, obtidas no aparelho ICat Classic®. Por meio do programa ICat Vision® foram mensuradas o diâmetro, a distância da FARAM ao forame incisivo (FARAM-FI), da FARAM ao rebordo alveolar vestibular (FARAM-RAV) e da FARAM a sutura intermaxilar (FARAM-SI). Também foi avaliada a trajetória dos canais ósseos formados a partir da FARAM. Nos pacientes dentados, foram localizados por meio da área dos dentes: incisivo central, incisivo lateral e caninos. Foi realizada a correlação entre a presença da FARAM e o gênero e a idade. Dos 150 exames, a FARAM estava presente em 21 exames (14%). Destes, dez pacientes eram edêntulos na região de interesse de estudo e não foi possível localizar a foramina em relação aos dentes. Nenhum exame apresentou a FARAM relacionada ao incisivo central, em sete estavam relacionadas ao incisivo lateral e em quatro estavam relacionadas ao canino. Nenhum exame apresentou a FARAM bilateralmente, sendo que treze foram localizadas no lado direito e oito do lado esquerdo. O diâmetro médio da FARAM foi de 1,57 ± 0,38 mm. As médias das distâncias de FARAM-RAV foi de 11,65 ± 3,34 mm, FARAM-FI foi de 8,86 ± 2,72 mm e FARAM-SI, foi de 6,37 ± 2,9 mm. A trajetória do canal ósseo mais comum foi ascendente/oblíqua em direção a região anterior do assoalho da cavidade nasal. A correlação entre a presença da FARAM e o gênero foi estaticamente significante para os homens (p=0,055) no teste do qui-quadrado. No entanto, não foi estatisticamente significante para a idade. / Through cone beam computed tomography (CBCT) is possible to evaluate the region of interest before surgical procedures in tridimensional view. Anatomical variations should be considered for performing surgeries, as the additional foraminas in anterior maxilla (AFAM). The main aim of the present study is evaluate AFAM in 150 CBCT exams, obtained through ICat Classic® device. In ICat Vision® software, the diameter, the distance from the AFAM to the incisive foramen (AFAM-IF), AFAM to the vestibular alveolar ridge (AFAM-VAR) and AFAM intermaxillary suture (AFAM-IS) were measured. It was also evaluated the trajectory of the bony canals related to AFAM. In dentate patients, AFAM was located through the teeth area: central incisor, lateral incisor and canines. The correlation between the presence of FARAM and gender and age was investigated. The AFAM was presented in 21 exams (14%). In the positive exams, 10 patients were edentulous in the region of study interest and it was not possible to locate the foramen in relation to the teeth. Any exam presented the AFAM related to the central incisor, in seven were related to the lateral incisor and in four were related to the canine. Any exam presented the AFAM bilaterally, of which thirteen were located on the right side and eight on the left side. The mean diameter of the AFAM was 1.57 ± 0.38 mm. The distance of the AFAM-VAR 11.65 ± 3.34 mm, AFAMIF was 8.86 ± 2.72 mm and AFAM-IS was 6.37 ± 2.9 mm. The most common bone canal trajectory was upward/ oblique to the anterior region of the floor of the nasal cavity. The correlation between the presence of AFAM and the gender was statically significant for males (p=0.055) in the chi-square test. However, it was not statistically significant for age.
63

Tomografia computadorizada por feixe cônico para detecção de lesões incipientes de furca simuladas em mandíbulas suínas maceradas / Cone beam computed tomography for detection of incipient furcation invasion in pig mandibles

Umetsubo, Otávio Shoiti 04 July 2011 (has links)
As radiografias intraorais ilustram bem os estágios de reabsorção periodontal nas regiões interproximais. Entretanto, a sobreposição de estruturas dificulta avaliação da perda óssea nas corticais vestibular e lingual. A tomografia computadorizada por feixe cônico (TCFC) é de elevada importância em várias especialidades odontológicas, tais como implantodontia, avaliação de lesões ósseas, estudo da articulação têmporo-mandibular e cirurgia buco-maxilo-facial. A TCFC também tem tido crescente indicação em outras áreas, como a periodontia e endodontia. O objetivo no presente estudo foi a) estabelecer o protocolo de aquisição mais adequado para a detecção de lesões incipientes de furca simuladas quimicamente; e b) avaliar a reprodutibilidade, sensibilidade e especificidade da TCFC, para a finalidade previamente citada. No presente estudo, foram utilizadas 15 mandíbulas suínas maceradas, que apresentavam o segundo molar íntegro e as corticais adjacentes preservadas As simulações de lesões em região de furca foram feitas com aplicação de ácido perclórico a 70%, em até quatro sítios possíveis em cada mandíbula (vestibular do lado direito, lingual do lado direito, vestibular do lado esquerdo, lingual do lado esquerdo) por um examinador participante que não avaliou as imagens. Nos 60 sitios possíveis, foram escolhidos aleatoriamente 20 para as simulações das lesões. Posteriormente, as mandíbulas foram submetidas à TCFC (i-CAT Next Generation) em dois. protocolos de aquição: voxel 0,2 mm e 0,25 mm, ambos com FOV de 6 cm de altura por 16 cm de diâmetro e com 26,9 segundos de tempo. Dois observadores (radiologistas previamente calibrados) avaliaram os exames duas vezes, em ordem aleatória, sob iluminação controlada. Os observadores foram orientados a direcionar a avaliação das regiões dos segundos molares, e questionados se havia lesão ou não nos sítios avaliados. A interpretação das imagens foi realizada em uma estação de trabalho independente localizada no Laboratório de Imagem em Terceira Dimensão da Faculdade de Odontologia da Universidade de São Paulo, utilizando o software Xoran (Xoran Technologies). A sensibilidade, especificidade e reprodutibilidade da TCFC foram avaliadas nos dois protocolos. A TCFC apresentou especificidade alta, sensibilidade baixa e reprodutibilidade moderada na detecção de lesões incipientes de furca. A influência do tamanho do voxel não foi estatisticamente significativa na detecção destas lesões. / Intraoral radiographs illustrate the stages of resorption in periodontal interproximal regions. However, overlapping structures hinders evaluation of bone loss in the buccal and lingual cortical plates. The cone beam computed tomography (CBCT) is of high importance in various dental specialties such as implantology, evaluation of bone lesions, the study of temporomandibular joint and maxillo-facial surgery. The CBCT has also been increasing indications in other areas, such as periodontics and endodontics. The aim of this study was to establish a) the acquisition protocol most suitable for the detection of incipient furcation invasion chemically simulated and b) assess the reproducibility, sensitivity and specificity of CBCT for the purpose previously mentioned. In this study, 15 pigs macerated mandibles were used, which showed the second molar and the adjacent cortical integrity preserved. Simulated lesions in the furcation area were made with application of 70% perchloric acid, up to four possible sites in each jaw (the right buccal, the right lingual, the left buccal, and left lingual side) by an examiner participant who did not evaluate the images. In the 60 possible sites, 20 were randomly chosen for the simulated lesions. Subsequently, the mandibles underwent cone beam computed tomography (Next Generation i-CAT) in two acquisition protocols: at 0.2 mm and 0.25 mm voxel, both with FOV of 6 cm height by 16 cm in diameter and 26.9 seconds of time. Two observers (calibrated radiologists) evaluated the examinations twice, in random order under controlled lighting. Observers were instructed to direct the evaluation to the regions of the second molars, and they were asked if there were or not injuries on those avaluated sites. Image interpretation was performed on an independent workstation located at the Third Dimension Laboratory of Image in the School of Dentistry, University of São Paulo, using the software Xoran (Xoran Technologies). The sensitivity, specificity and reproducibility of CBCT were assessed in both trials. The CBCT showed high specificity, low sensitivity and moderate reproducibility in the detection of incipient lesions, furcation. The influence of voxel size was not statistically significant in detecting these lesions.
64

Prevalência de nódulos pulpares em molares : análise em tomografia computadorizada de feixe cônico /

Vasques, Ana Maria Veiga. January 2019 (has links)
Orientador: Eloi Dezan Junior / Banca: Gustavo Sivieri de Araújo / Banca: Rodrigo Ricci Vivan / Resumo: Nódulos pulpares são calcificações presentes na câmara pulpar, aderidos nas paredes dentinárias ou como nódulos soltos e podem bloquear parcialmente ou totalmente o acesso aos orifícios dos canais radiculares. Devido à limitação de estudos realizados anteriormente com radiografias, o objetivo desse trabalho foi determinar a prevalência de nódulos pulpares por meio da tomografia computadorizada de feixe cônico (TCFC) e explorar qualquer correlação potencial entre a ocorrência de nódulos pulpares com gênero, idade, dente, arcada e estado da coroa dentária. Para isso foram utilizadas TCFC de 300 pacientes, totalizando 631 molares. Todos os molares foram analisados nos planos sagital, axial e coronal e, quando presentes, os nódulos pulpares foram identificados como uma massa redonda ou oval hiperdensa. Após tabulação dos dados, a análise estatística foi realizada através da aplicação de testes de qui-quadrado. De um total de 300 pacientes, os nódulos pulpares foram identificados em 35% e em 25.5% dos 631 molares analisados. A presença dos nódulos pulpares foi mais frequente no sexo feminino (41.1%) do que no masculino (27.7%) e nos indivíduos com idade acima de 80 anos. Os primeiros molares superiores exibiram a maior incidência de nódulos pulpares. Nenhuma diferença significativa foi observada quando os arcos maxilar e mandibular e os lados foram comparados. A presença de nódulos pulpares foi elevada em molares restaurados quando comparados aos dentes íntegros (P <0,05). A Tomog... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Pulp stones are calcifications present in the pulp chamber adhered to dentin walls or as loose nodules and can partially or totally block access to root canals entrance. Due to radiographic limitation of previous reports, the objective of this study was to determine the prevalence of pulp stones by cone beam computerized tomography (CBCT) and to explore any potential correlation between the occurrence of pulp stones with gender, age, tooth, arches and condition of the dental crown. CBCT of 300 patients were assessed, totaling 631 molars. All molars were analyzed in the sagittal, axial and coronal planes and, when present, pulp stones were identified as a round or oval hyperdense mass. After data tabulation, statistical analysis was performed using chi-square tests. Of a total of 300 patients, pulp stones were identified in 35% and in 25.5% of the 631 analyzed molars. The presence of pulp stones was most frequently found in females (41.1%) than in males (27.7%) and in individuals aged over 80 years. The first upper molars showed the highest incidence of pulp stones. No significant difference was observed when maxillary and mandibular arches were compared neither sides. The presence of pulp stones was higher in restored molars when compared to intact teeth (P <0.05). Cone Beam Computerized Tomography is an efficient resource for the diagnosis and location of pulp stones (Complete abstract electronic access below) / Mestre
65

Avaliação das dimensões da nasofaringe através da tomografia computadorizada e pela rinomanometria anterior modificada em indivíduos com fissura labiopalatina submetidos à cirurgia ortognática / Evaluation of nasopharyngeal dimensions through computed tomography and modified anterior rhinomanometry in patients with cleft lip and palate submitted to orthognathic surgery

Medeiros, Maria Carolina Malta 01 March 2019 (has links)
As alterações volumétricas da cavidade oral, nasal e espaço faríngeo após a cirurgia ortognática, têm sido objetivo de muitos estudos, uma vez que, essas alterações dependem da direção e magnitude da movimentação dos segmentos ósseos, porém, poucos são os trabalhos que combinam os diferentes métodos para a avaliação da nasofaringe. O objetivo deste estudo foi correlacionar o espaço aéreo faríngeo em pacientes com fissura labiopalatina, submetidos à cirurgia ortognática com avanço de maxila e/ou recuo de mandíbula, por meio da análise do volume e área seccional mínima utilizando imagens de tomografia computadorizada de feixe cônico e pela rinomanometria anterior modificada (técnica fluxo-pressão) no pré e pós-operatório de um ano da cirurgia ortognática. Desse modo, a amostra foi composta por 41 indivíduos, que foram avaliados no pré-operatório e no pós-operatório, na qual, avaliou-se a área seccional mínima pela rinomanometria anterior modificada expressos em mm2 e pelas imagens de tomografia de feixe cônico, que foram importadas em DICOM e avaliadas pelo software Dolphin Imaging 11.0, obtendo os valores numéricos de volume (V), expressos em cm3, bem como a área seccional mínima, expressa em mm2. Notou-se que, em todas as variáveis, houve aumento médio dos valores no pós-operatório em relação ao pré-operatório. Além disso, notouse uma diferença estatisticamente significante ao comparar os resultados dos volumes e da área seccional mínima da área nasofaríngea no pré e pós-operatório pelo software Dolphin Imaging 11.0 ao aplicar o Teste de Wilcoxon. Observou-se também, o aumento discreto da área nasofaríngea avaliada pela rinomanometria, no préoperatório de 105,9 mm2 para 107,1 mm2 no pós-operatório, mas sem diferença estatisticamente significante com p=0,493 pelo Teste de Wilcoxon. E ao comparar a ASM pela TCFC (ASMD) e pela rinomanometria (notou-se diferença estatística (p= 0,033) pelo Teste de Wilcoxon. Por conseguinte, concluiu-se que, existe diferença estatisticamente significante entre a área seccional mínima obtida da TCFC com a rinomanometria pela técnica de fluxo-pressão. / The volumetric changes of the oral cavity, nasal cavity and pharyngeal space after orthognathic surgery have been the objective of many studies, since these alterations depend on the direction and magnitude of the movement of the bone segments, however, there are few studies that combine the different methods for evaluating the nasopharynx. The objective of this study was to correlate the pharyngeal air space in patients with cleft lip and palate submitted to orthognathic surgery with maxillary advancement and / or mandible retreatment, by means of volume analysis and minimum sectional area using conical beam computed tomography by modified anterior rhinomanometry (flow-pressure technique) in the pre- and postoperative year of orthognathic surgery. Thus, the sample consisted in 41 individuals, which were evaluated preoperatively and postoperatively, in which the minimum sectional area was determined by modified anterior rhinomanometry expressed in mm2 and by conical beam tomography images, which were imported into DICOM and evaluated by Dolphin Imaging 11.0 software, obtaining the numerical values of volume (V), expressed in cm3, as well as the minimum sectional area, expressed in mm2. It was observed that, in all variables, there was an average increase in postoperative values in relation to the preoperative period. In addition, a statistically significant difference was observed when comparing the results of the volumes and the minimum sectional area of the nasopharyngeal area in the pre and postoperative period by the Dolphin Imaging 11.0 software when applying the Wilcoxon Test. It was also observed a discrete increase in the nasopharyngeal area evaluated by rhinomanometry, in the preoperative period from 105.9 mm2 to 107.1 mm2 postoperatively, but without a statistically significant difference with p = 0.493 by the Wilcoxon test. When comparing ASM by CBCT (ASMD) and rhinomanometry (a statistical difference (p = 0.033) was noted by the Wilcoxon test. Therefore, it was concluded that there is a statistically significant difference between the minimum sectional area obtained from the CBCT with rhinomanometry.
66

Mapeamento tridimensional do ápice radicular em relação às corticais ósseas externas e estruturas anatômicas adjacentes /

Ferrari, Carlos Henrique. January 2017 (has links)
Orientador: Frederico Canato Martinho / Banca: Márcia Carneiro Valera Garakis / Banca: Cláudio Antonio Talge Carvalho / Banca: Luiz Alexandre Thomaz / Banca: Maria Rachel Figueiredo Penalva Monteiro / Resumo: O conhecimento da posição topográfica dos ápices dentários em relação às corticais ósseas externas e estruturas anatômicas é de importância para a endodontia, sobretudo quando da instituição de técnicas com sobreinstrumentação. A tomografia computadorizada de feixe cônico (TCFC) permite uma análise tridimensional da localização do ápice radicular, estimando os riscos em relação a essas estruturas. Os objetivos desta pesquisa foram: a) aferir a medida linear entre os ápices radiculares de dentes posteriores e canino superiores e o seio maxilar e entre os ápices de dentes posteriores inferiores e o canal mandibular, relacionando os achados com gênero e idade; b) comparar as medições realizadas em tomografias entre ápices e estruturas anatômicas, com as realizadas em radiografias panorâmicas; c) verificar a proximidade dos ápices radiculares dos dentes superiores com a respectiva cortical óssea externa adjacente e dos ápices radiculares dos dentes inferiores com as corticais ósseas externas vestibular e lingual; d) verificar a ocorrência de fenestrações apicais, em todos os grupos dentais e e) classificar riscos de sobreinstrumentação baseando-se nas medidas lineares entre ápices radiculares e estruturas anatômicas/ corticais ósseas externas. Foram selecionados 800 TCFCs e 200 radiografias panorâmicas obtidas de pacientes com indicações diversas. Na TCFC, foram encontradas médias entre os ápices radiculares e o seio maxilar, variando de 0,37mm até 6,22mm, e na mandíbula, entre o... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: It is important to know the topographic position of dental root apices in relation to external cortical bones and adjacent anatomical structures for endodontics, mainly regarding the use of over-instrumentation techniques. Cone beam computed tomography (CBCT) allows for analysis of the root apex position and estimation of the risks in relation to these structures. The objectives of this study were: a) to assess the linear measurement between root apices of posterior teeth and upper canine and maxillary sinus as well as between apices of lower posterior teeth and mandibular canal according to gender and age; b) to compare tomographic measurements of apices and anatomical structures to those from panoramic radiographs; c) to verify the proximities of the root apices of upper teeth to corresponding adjacent cortical bones and of lower teeth to buccal and lingual cortical bones; d) to verify the occurrence of apical fenestrations in all dental groups; and e) to assess the risks of overinstrumentation based on linear measurements between root apices and anatomical structures/external cortical bones. A total of 800 tomographs and 200 panoramic radiographs were selected. CBCT images showed mean distances between root apices and maxillary sinus ranging from 0.37mm to 6.22mm and between root apices and mental foramen ranging from 2.81mm to 4.92mm. By comparing the tomographs to panoramic radiographs, over-estimation and sub-estimation were found in the maxillary and mandibular measurements, respectively (P < 0.01). The distances between each root apex and corresponding cortical bone were ranked according to distance, with the majority of the apices located less than 1 mm from the cortical bone in the maxilla and greater than 3mm in the mandible. Higher rates of fenestrations were found in the maxilla, whereas lingual bone plate was more affected in the mandible. ...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor
67

Avaliação tomográfica da cobertura óssea em diferentes tipos de padrão esquelético e inclinação dos incisivos

Lessa, Anne Maria Guimarães January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2016-09-08T13:09:54Z No. of bitstreams: 1 Dissertação_ODONTO_ Anne Maria Guimarães Glessa.pdf: 2049486 bytes, checksum: 3cfa2e4b181a698e0a21b95a118212db (MD5) / Approved for entry into archive by Uillis de Assis Santos (uillis.assis@ufba.br) on 2016-10-05T11:36:01Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Anne Maria Guimarães Glessa.pdf: 2049486 bytes, checksum: 3cfa2e4b181a698e0a21b95a118212db (MD5) / Made available in DSpace on 2016-10-05T11:36:01Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Anne Maria Guimarães Glessa.pdf: 2049486 bytes, checksum: 3cfa2e4b181a698e0a21b95a118212db (MD5) / CAPES / O estudo da estrutura de suporte dentário apresenta importante papel no planejamento odontológico dos indivíduos, com destaque para a cobertura óssea (CO). É possível que o padrão esquelético e a inclinação dos incisivos estejam relacionados com esta CO e tem sido demonstrado que a avaliação desta pela Tomografia Computadorizada de Feixe Cônico (TCFC) representa uma ferramenta auxiliar no diagnóstico. O objetivo desse trabalho foi correlacionar o diagnóstico de CO com o padrão esquelético e a inclinação dos incisivos. Para tanto, foi utilizada uma amostra de conveniência com exames tomográficos selecionados de indivíduos a ser submetidos a tratamento ortodôntico, e foram aplicados os critérios de exclusão para obtenção da amostra final. O padrão esquelético foi determinado através do ângulo ANB e pela análise de Wits, e a inclinação dos incisivos, através das medidas 1.NA, 1-NA, 1.NB, 1-NB e ângulo interincisal (1:1). Dois avaliadores treinados analisaram e classificaram a CO em 15 indivíduos de cada um dos três padrões esqueléticos, em cada terço dos dentes anteriores, como crítica, delgada, regular ou espessa. Houve concordância entre a condição dos indivíduos classificados pelo ANB e Wits, visto que ambos apresentam melhor condição de CO no padrão esquelético de classe II e menor CO nas classes I e III, com condição menos grave na classe I avaliada pelo Wits. No universo desta amostra percebeu-se maior proporção de defeitos ósseos nos terços médios, equivalendo a 411 (76%) terços médios concordantes entre os avaliadores do total de 540 avaliados, embora não estatisticamente significante (p<0,05), pela distribuição uniforme. O terço apical apresentou melhores condições e a maior representatividade de CO regular e espessa. A CO crítica foi mais observada no terço cervical dos incisivos centrais inferiores (ICI) e incisivos laterais inferiores (ILI); no médio do canino superior (CS) e ILI; e no apical em ICI e canino inferior (CI). Os incisivos centrais superiores (ICS) e incisivos laterais superiores (ILS) apresentaram menor CO quando estavam mais verticalizados, repetindo-se principalmente nos terços médios e apicais com a maior retrusão dos ICS. A maior vestibularização dos incisivos superiores estava associada à menor CO nos terços cervicais dos ICI e ILI. No ICI, observou-se menor CO no cervical quando os incisivos inferiores estavam mais verticalizados e retraídos. Sendo assim, maior cuidado deve ser dado na avaliação dos incisivos inferiores, uma vez que estes apresentaram a pior condição de CO e essa situação é ainda mais agravada em dentes mais verticalizados, tendo o padrão esquelético de classe III a maior proporção de CO crítica dentre as demais.
68

Efeito da expansão rápida da maxila sobre o osso alveolar vestibular: estudo por TCFC

Barbosa, Marcelo de Castelucci e January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2016-11-23T13:37:35Z No. of bitstreams: 1 TESE DOUTORADO MARCELO DE CASTELLUCCI.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Approved for entry into archive by Uillis de Assis Santos (uillis.assis@ufba.br) on 2016-11-23T13:43:59Z (GMT) No. of bitstreams: 1 TESE DOUTORADO MARCELO DE CASTELLUCCI.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Made available in DSpace on 2016-11-23T13:44:00Z (GMT). No. of bitstreams: 1 TESE DOUTORADO MARCELO DE CASTELLUCCI.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Este estudo experimental tem o objetivo de avaliar, através de tomografia computadorizada de feixe cônico, alterações no osso alveolar vestibular e na inclinação dos primeiros molares superiores permanentes, após expansão rápida da maxila. Foram utilizadas 40 imagens, de 20 pacientes, com idades variando de 10 a 14 anos, sendo 15 do gênero masculino e 5 do feminino, realizadas antes e após a expansão rápida da maxila, feita com o aparelho disjuntor tipo Haas. Utilizando o programa Dolphin Imaging versão 11.0 Premium e a partir da reconstrução multiplanar, foi medida a espessura do osso vestibular às raízes dos primeiros molares, nos terços apical, médio e cervical, além da distância entre a junção amelocementária e a crista óssea alveolar. Foram medidos, também, os ângulos formados entre o longo eixo dos primeiros molares superiores e o palato. Para a análise das diferenças entre as medidas dos dois tempos, utilizou-se o teste t de Student. Para testar a associação entre as variáveis, utilizou-se a análise de correlação de Pearson, todos com nível de significância de 95%. Observou-se um aumento significativo no ângulo formado entre os primeiros molares superiores e o palato duro, assim como nas medidas de largura do palato. Não houve alterações significativas de espessura óssea vestibular aos primeiros molares, nas porções apical e média das raízes. No entanto, houve uma diminuição dessa espessura na porção cervical das raízes desses dentes. Não foram encontradas alterações na distância entre a junção amelocementária e a crista alveolar. Não houve relação das alterações na espessura da cortical óssea alveolar vestibular com a mudança de inclinação vestibulolingual desses dentes, nem com a quantidade de expansão realizada. Contudo, foi encontrada uma correlação positiva entre a diminuição de espessura da cortical óssea vestibular, na porção cervical, e a espessura inicial dessa medida. Dentre os parâmetros avaliados, a única variável que apresentou diminuição foi a espessura óssea vestibular às raízes dos primeiros molares, na porção cervical. / This longitudinal clinical study used cone beam computed tomography to evaluate changes in alveolar bone and inclination of maxillary first molars after rapid maxillary expansion. Cone beam computed tomography images of 20 patients (15 male and 5 female), aged from 10 to 14 years old, were used, captured before and after expansion with Haas type appliance. In multiplanar reconstructions made with Dolphin Imaging 11.0 Premium software, vestibular bone thickness was measured at apical, middle and cervical thirds of these roots, in addition to distance between the amelocemental junction and alveolar bone crest. Palatal width and the angles formed between the long axis of the maxillary first molars and palate were also measured. There were significant increase in the angle formed between the long axis of the maxillary first molars and palate and also in palatal width. There were no significant changes in vestibular bone thickness in the apical and middle portions of the roots. However, there was decrease in this thickness in the cervical portion. No changes were found in the distance between the amelocemental junction and alveolar crest. There was no relation between the changes in thickness of the vestibular alveolar bone and change in inclination of these teeth, or quantity of expansion performed. However, positive correlation was found between the reduction in vestibular cortical bone thickness in the cervical portion and the initial thickness of this measurement. Among the periodontal parameters evaluated, the only variable that presented any reduction was the vestibular bone thickness in the cervical portion of the first molar roots.
69

Acurácia de medidas cefalométricas em diferentes exames de imagem

Barreto, Mônica Sena January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2016-11-29T14:22:11Z No. of bitstreams: 1 Acurácia de medidas cefalométricas em diferentes exames de imagem - Dissertação - Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2016-12-19T15:11:11Z (GMT) No. of bitstreams: 1 Acurácia de medidas cefalométricas em diferentes exames de imagem - Dissertação - Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Made available in DSpace on 2016-12-19T15:11:11Z (GMT). No. of bitstreams: 1 Acurácia de medidas cefalométricas em diferentes exames de imagem - Dissertação - Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / CAPES / O exame de tomografia computadorizada (TC) trouxe para a cefalometria novos recursos, inclusive a possibilidade de avaliação tridimensional. Dentre os equipamentos de TC, destaca-se o sistema de aquisição de imagem denominado de TC de feixe cônico (TCFC) ou cone beam, especialmente dedicado ao estudo tomográfico da face. Diante da sua crescente utilização em Ortodontia, o objetivo deste estudo foi avaliar a acurácia de medidas lineares realizadas em reconstruções multiplanares (RMP) e reconstruções sagitais (RS) da hemi-face esquerda obtidas a partir de TCFC pelo software Dolphin Imaging 3D®, comparando-as com as mesmas medidas realizadas em radiografias cefalométricas de perfil. Para isto, dez crânios secos foram submetidos a telerradiografias em norma lateral e a TCFC (com voxels de 0,25 mm, 0,3 mm e 0,4 mm). As radiografias e os dados da TCFC foram importados para um software, no qual essas últimas foram processadas, seguindo os parâmetros default do programa, para obtenção de RMP e RS da hemi-face esquerda. Em cada imagem foram aferidas distâncias lineares, utilizando-se as réguas eletrônicas do programa. Medidas realizadas nos crânios secos com auxílio de um paquímetro digital foram consideradas o padrão-ouro. As medidas foram realizadas por dois avaliadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram não haver diferenças significativas nas medidas realizadas nas diferentes modalidades de imagem e nos crânios secos. Em relação aos erros absoluto e relativo, observou-se que houve diferença significante entre as medidas realizadas na telerradiografias em norma lateral e aquelas das RS, nos três tamanhos de voxel. A maior média de erro foi observada na telerradiografia em normal lateral, seguida da RMP e da RS. Do exposto pode-se concluir que as medidas cefalométricas nas imagens derivadas da reconstrução da TCFC, independentemente do tamanho do voxel, são reproduzíveis e válidas, se comparadas com as medidas obtidas na telerradiografia em norma lateral. / Computed tomography (CT) brought to cephalometrics new features, including the possibility of three-dimensional evaluation. Among the CT equipment, there is the image acquisition system called cone beam CT (CBCT), especially dedicated to the CT scan of the face. The aim of this study was to evaluate the accuracy of linear measurements performed in multiplanar reconstructions (RMP) and sagittal reconstructions (RS) from the left hemi-face obtained from the CBCT software Dolphin Imaging 3D®, comparing with the same measurements in cephalometric radiographs. For this, ten dry skulls underwent lateral cephalometric radiographs and CBCT (with voxels of 0.25 mm, 0.3 mm and 0.4 mm). Radiographs and data from CBCT were imported into software, in which these latter were processed following the default parameters, to obtain RMP and RS of the hemi-face left. In each image were measured linear distances, using the electronic program rules. Measurements in dry skulls with the aid of a digital caliper were considered the gold standard. Two observers, performed the measurements twice, and the data were compared and analyzed statistically. The results showed no significant differences in measurements performed in different imaging modalities and dry skulls. Regarding the absolute and relative errors, we observed a significant difference between the measurements in lateral cephalometric radiographs and those of the RS, at the three-voxel sizes. The highest average error was observed in the lateral radiograph at normal, then the RMP and the RS. From the above, it can conclude that the cephalometric measurements on the images derived from the CBCT reconstruction, regardless of the voxel size, are reproducible and valid, when compared with the measurements obtained in radiography in lateral view.
70

Acurácia de medidas cefalométricas em diferentes exames de imagem

Barreto, Mônica Sena January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-02-14T12:35:56Z No. of bitstreams: 1 Dissertação_ODONTO_ Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-06-29T12:30:06Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Made available in DSpace on 2017-06-29T12:30:06Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / CAPES / O exame de tomografia computadorizada (TC) trouxe para a cefalometria novos recursos, inclusive a possibilidade de avaliação tridimensional. Dentre os equipamentos de TC, destaca-se o sistema de aquisição de imagem denominado de TC de feixe cônico (TCFC) ou cone beam, especialmente dedicado ao estudo tomográfico da face. Diante da sua crescente utilização em Ortodontia, o objetivo deste estudo foi avaliar a acurácia de medidas lineares realizadas em reconstruções multiplanares (RMP) e reconstruções sagitais (RS) da hemi-face esquerda obtidas a partir de TCFC pelo software Dolphin Imaging 3D®, comparando-as com as mesmas medidas realizadas em radiografias cefalométricas de perfil. Para isto, dez crânios secos foram submetidos a telerradiografias em norma lateral e a TCFC (com voxels de 0,25 mm, 0,3 mm e 0,4 mm). As radiografias e os dados da TCFC foram importados para um software, no qual essas últimas foram processadas, seguindo os parâmetros default do programa, para obtenção de RMP e RS da hemi-face esquerda. Em cada imagem foram aferidas distâncias lineares, utilizando-se as réguas eletrônicas do programa. Medidas realizadas nos crânios secos com auxílio de um paquímetro digital foram consideradas o padrão-ouro. As medidas foram realizadas por dois avaliadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram não haver diferenças significativas nas medidas realizadas nas diferentes modalidades de imagem e nos crânios secos. Em relação aos erros absoluto e relativo, observou-se que houve diferença significante entre as medidas realizadas na telerradiografias em norma lateral e aquelas das RS, nos três tamanhos de voxel. A maior média de erro foi observada na telerradiografia em normal lateral, seguida da RMP e da RS. Do exposto pode-se concluir que as medidas cefalométricas nas imagens derivadas da reconstrução da TCFC, independentemente do tamanho do voxel, são reproduzíveis e válidas, se comparadas com as medidas obtidas na telerradiografia em norma lateral.

Page generated in 0.0724 seconds