• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 24
  • 23
  • 17
  • 17
  • 16
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementation

Pedreira, Ana Paula Ribeiro do Vale 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.
2

Avaliação da dureza superficial de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro

Grande, Fernanda Zander 21 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:11Z (GMT). No. of bitstreams: 1 Fernanda Zander.pdf: 940456 bytes, checksum: 47429e6712305973cd3b486e5ac590f1 (MD5) Previous issue date: 2006-02-21 / The purpose of this study was to investigate the interaction between two methods of adhesive systems activation (chemically cured and dual cured) and two methods of resin cements activation (chemically cured and dual cured) in Vickers microhardness values of resin cements, in differents depths of cure and differents distances of the adhesive systems used. There were 50 bovin inferior incisives which had their crowns transversaly crosscuted to use the root portion. The canal roots were prepared to the fiber posts cementation. The teeth were randomly divided in five groups: I) Adhesive system Prime & Bond 2.1 with Self Cure Activator and dual resin cement EnForce; II) Adhesive system Prime & Bond 2.1 and dual resin cement EnForce; III) ED Primer and chemically cured resin cement Panavia 21; IV) Adhesive system Clearfil SE Bond and chemically cured resin cement Panavia 21 e V) Adhesive system Prime & Bond 2.1 with Self Cure Activator and dual resin cement EnForce. In group V The EnForce wasn’t light-cured standing only with the chemically activation. After posts cementation the roots were cuted in 3 portions with 3 mm eatch (cervical, medium and apical) and after 7 days the specimens were tested. The specimens were divided in quadrants that recived 2 identations, one next the fiber post and other next the canal root surface. Data were submitted to threeway ANOVA and Tukey’s test. The application of these tests revealed statistically significant differences for the variables: group, position, region; interaction between group and position (p< 0,001), and interaction between group and region (p= 0,041). There weren’t, however, statistically significant differences interaction between position and region (p= 0.85). The conclusions were: the superficial hardness, independently of the kind of cement and adhesive system was always present in all regions of root canal; the chemically cured resin cement demonstrated the higher values of hardness; the factor depth of cure interfered in superficial hardness values in all groups, being more evident in GI and GII than GIII, GIV e GV; there was interference of adhesive systems in microhardness values for all groups, what can be observed in smaller values found next the adhesive systems. It was more evident in GIV that used the self-etched adhesive system and less evident in GIII that used ED Primer. The findings of this study demonstrates that the pH of adhesive systems inluences the microhardness values of resin cements. / O objetivo deste trabalho foi analisar a interação de dois tipos de ativação de sistemas adesivos (fotoativável e ativação dual) e dois tipos de ativação de cimentos resinosos (ativação química e ativação dual) nos valores de microdureza Vickers dos cimentos em diferentes profundidades de polimerização e diferentes proximidades com o sistema adesivo utilizado. Foram utilizados 50 incisivos bovinos inferiores que tiveram suas coroas seccionadas transversalmente para a utilização da porção radicular. Os condutos radiculares foram preparados para a cimentação de pino de fibra de vidro. Os dentes foram divididos aleatoriamente em cinco grupos: I) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce; II) Sistema adesivo Prime & Bond 2.1 e cimento resinoso dual EnForce; III) ED Primer e cimento resinoso químico Panavia 21; IV) Sistema adesivo Clearfil SE Bond e cimento resinoso químico Panavia 21 e V) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce. No grupo V o cimento EnForce não foi fotoativado ficando apenas com a ativação química. Após a cimentação dos pinos as raízes foram então seccionadas em três secções de 3 mm de espessura (cervical, média e apical) e após sete dias foi feita a análise da microdureza Vickers. As secções de cada terço foram divididas em quadrantes iguais e em cada quadrante foram realizadas duas identações, sendo uma próxima ao pino de fibra de vidro e a outra próxima à parede do conduto radicular. Os resultados foram submetidos à análise estatística ANOVA três critérios, havendo diferença estatística entre os grupos foi feito o teste de Tukey para a comparação dos grupos dois a dois. A aplicação do teste de Análise de Variância à três critérios revelou haver diferenças estatisticamente significantes para as variáveis independentes: grupo, posição, região, interação entre grupo e posição (p<0,001), e interação entre grupo e região (p=0,041), não havendo, contudo, diferença estatisticamente significante para as interações entre posição e região (p=0,983) e para a interação entre grupo, posição e região (p=0,85). Concluiu-se que: a dureza superficial, independente do tipo de cimento e dos sistemas adesivos esteve sempre presente em todas as regiões analisadas do canal radicular; o cimento resinoso quimicamente ativado (GIII) apresentou maiores valores de dureza superficial quando comparado ao cimento resinoso de dupla ativação, independente da região analisada do canal radicular; o fator profundidade de polimerização interferiu nos valores de dureza superficial em todos os grupos, sendo mais evidente para os grupos onde o cimento foi fotoativado (GI e GII) do que para os grupos com ativação química (GIII, GIV e GV) que mostraram maior uniformidade nos três terços do conduto radicular; Houve interferência dos sistemas adesivos utilizados nos valores de microdureza para todos os grupos, o que pode ser observado nos menores valores encontrados próximo aos sistemas adesivos, sendo mais evidente no GIV que utilizou o sistema adesivo autocondicionante e menos evidente no grupo III que utilizou o Primer do próprio cimento, mostrando a incompatibilidade entre os sistemas adesivos com menor pH e a fase quimicamente ativada dos cimentos resinosos. O objetivo deste trabalho foi analisar a interação de dois tipos de ativação de sistemas adesivos (fotoativável e ativação dual) e dois tipos de ativação de cimentos resinosos (ativação química e ativação dual) nos valores de microdureza Vickers dos cimentos em diferentes profundidades de polimerização e diferentes proximidades com o sistema adesivo utilizado. Foram utilizados 50 incisivos bovinos inferiores que tiveram suas coroas seccionadas transversalmente para a utilização da porção radicular. Os condutos radiculares foram preparados para a cimentação de pino de fibra de vidro. Os dentes foram divididos aleatoriamente em cinco grupos: I) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce; II) Sistema adesivo Prime & Bond 2.1 e cimento resinoso dual EnForce; III) ED Primer e cimento resinoso químico Panavia 21; IV) Sistema adesivo Clearfil SE Bond e cimento resinoso químico Panavia 21 e V) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce. No grupo V o cimento EnForce não foi fotoativado ficando apenas com a ativação química. Após a cimentação dos pinos as raízes foram então seccionadas em três secções de 3 mm de espessura (cervical, média e apical) e após sete dias foi feita a análise da microdureza Vickers. As secções de cada terço foram divididas em quadrantes iguais e em cada quadrante foram realizadas duas identações, sendo uma próxima ao pino de fibra de vidro e a outra próxima à parede do conduto radicular. Os resultados foram submetidos à análise estatística ANOVA três critérios, havendo diferença estatística entre os grupos foi feito o teste de Tukey para a comparação dos grupos dois a dois. A aplicação do teste de Análise de Variância à três critérios revelou haver diferenças estatisticamente significantes para as variáveis independentes: grupo, posição, região, interação entre grupo e posição (p<0,001), e interação entre grupo e região (p=0,041), não havendo, contudo, diferença estatisticamente significante para as interações entre posição e região (p=0,983) e para a interação entre grupo, posição e região (p=0,85). Concluiu-se que: a dureza superficial, independente do tipo de cimento e dos sistemas adesivos esteve sempre presente em todas as regiões analisadas do canal radicular; o cimento resinoso quimicamente ativado (GIII) apresentou maiores valores de dureza superficial quando comparado ao cimento resinoso de dupla ativação, independente da região analisada do canal radicular; o fator profundidade de polimerização interferiu nos valores de dureza superficial em todos os grupos, sendo mais evidente para os grupos onde o cimento foi fotoativado (GI e GII) do que para os grupos com ativação química (GIII, GIV e GV) que mostraram maior uniformidade nos três terços do conduto radicular; Houve interferência dos sistemas adesivos utilizados nos valores de microdureza para todos os grupos, o que pode ser observado nos menores valores encontrados próximo aos sistemas adesivos, sendo mais evidente no GIV que utilizou o sistema adesivo autocondicionante e menos evidente no grupo III que utilizou o Primer do próprio cimento, mostrando a incompatibilidade entre os sistemas adesivos com menor pH e a fase quimicamente ativada dos cimentos resinosos.
3

Retenção em canais amplos de núcleos confeccionados por diferentes técnicas com pinos fibro resinosos / Retention of fiber posts made by diferent technics in enlarged root canals

Marcelo Nunes Heimlich 27 April 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O propósito desse trabalho foi verificar a retenção de pinos fibro resinosos cimentados em canais radiculares alargados simulando raízes extensamente comprometidas, fabricados por duas técnicas usadas para diminuir sua desadaptação; comparando-as ao pino fixado somente com cimento. Foram utilizados vinte e quatro raízes de dentes humanos unirradiculares, padronizadas com 15.0 mm de comprimento e 5.0 0.3 mm de diâmetro. As raízes foram incluídas em resina acrílica e divididas em grupos de acordo com a técnica usada: grupo I - pino DC White Post no2 cimentado com sistema adesivo quimicamente ativado e com cimento resinoso dual; grupo II mesmo pino reanatomizado com resina composta para copiar a anatomia do canal radicular, cimentado da mesma forma; e grupo III mesmo pino associado a três pinos acessórios, cimentados do mesmo modo. O canal radicular teve seu diâmetro padronizado pela broca no2 para o pino DC em uma profundidade de 12.0 mm e alargado com uma broca tronco cônica em uma profundidade de 10.0 mm. As oito raízes de cada grupo foram seccionadas transversalmente em três discos de 3.0 mm, a partir da cervical para a execução de um ensaio de extrusão, descartando-se os últimos 2.0 mm, que serviram somente para centralizar o pino. Os valores de retenção foram registrados e tratados estatisticamente por ANOVA e pelo teste SNK (p<0.05). Diferenças significativas foram observadas entre três porções radiculares investigadas em todos os grupos, com os valores de retenção diminuindo da cervical para apical. A retenção na porção apical do grupo com pinos customizado com resina foi estatisticamente maior que na mesma região dos demais grupos. Nenhuma diferença foi encontrada entre o grupo com pinos acessórios e o grupo somente com pino e cimento nessa parte da raiz. Nenhuma diferença foi observada comparando as porções cervical e média dos diferentes grupos. Os tipos de falha após o teste de extrusão foram observados em microscópio eletrônico de varredura com aumento de 200, 600 e 1000 vezes. Elas ocorreram exclusivamente entre o pino e o cimento ou a resina composta. A camada de adesão (camada híbrida) foi mais facilmente observada nas porções cervical e média de todos os grupos. Isso sugere que a retenção nas porções apicais da raiz é predominantemente friccional. Uma vez que pinos acessórios somente alcançam até a porção média do canal radicular, a retenção do pino não é aumentada com essa técnica. / The aim of this study was to evaluate the retention of fiber posts cemented in enlarged root canals simulating compromised roots, fabricated with to two techniques used to minimize your desadptation; comparing it to posts fixed only with ciment. Twenty four single root human teeth standardized in 15.0mm length and 5.0 0.3mm diameter were used. The roots were imbibed in acrylic resin and divided in groups according to the technique used: group I - DC White Post no2 cemented with quimically cured adhesive system and a dual cured resin cement; group II the same post customized with composite resin to copy the root canal anatomy, cemented the same way; and group III the same post associated with three accessory posts, cemented the same way. The root canals had their diameter standardized using a no2 DC post burs 12.0 mm deep and enlarged with a chamfer bur 10.0 mm deep. The eight roots of each group were transversely sectioned in three 3.0 mm diameter discs, starting from cervical to make the push out test, discarding the last 2.0mm used only to centralize the post. The retention values were registered and statistically treated with ANOVA and SNK tests (p<0.05). Significant differences were observed when comparing the three root portions of all groups investigated, with retention values decreasing from cervical to apical. The retention in apical portion of customized posts was statistically greater than the same parts of other groups. No differences were found between the group with accessory posts and only cemented posts in this root portion. No differences was observed comparing cervical e middle portions of different groups. The failure types after the push out test were observed in MEV with 200, 600 e 1000x magnification. They occurred exclusively between the post and the resin cement or the composite resin. A hybrid layer was more easily observed in the cervical and middle portions of the roots in all groups. This suggests that the retention in the apical portions of roots is mostly frictional. Since accessory posts only eventually can reach the middle portion of root canal the post retention is not increased with this technique.
4

Influência de dois tipos de retentores intra-radiculares e do tipo de coroa total na resistência e modo de fratura de raízes de incisivos superiores

Zamboni, Sandra Regina Oliveira Costa [UNESP] 22 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-22Bitstream added on 2014-06-13T20:45:50Z : No. of bitstreams: 1 zamboni_sroc_dr_sjc.pdf: 562964 bytes, checksum: 96289338fffdaef0884f0ad0364b5145 (MD5) / O objetivo neste estudo foi avaliar e comparar a resistência à fratura de incisivos centrais restaurados usando dois tipos de pinos intra-radiculares: núcleo metálico fundido e pinos de fibra de quartzo, reconstruídos com diferentes tipos de coroas. A hipótese nula testada foi que a resistência a fratura desses corpos de prova não apresentariam diferença quanto ao tipo de pino e tipo de coroa. Sessenta incisivos centrais superiores foram divididos em 6 grupos: G1- núcleo metálico fundido + coroa em cerômero, G2- núcleo metálico fundido + coroa metalo-cerâmica, G3- núcleo metálico fundido + coroa em e-max, G4 – pino de fibra de quartzo e pinos acessórios + coroa em cerômero, G5- pino de fibra de quartzo e pinos acessórios + coroa metalo-cerâmica e G6- pino de fibra de quartzo e pinos acessórios + coroa em e-max. Todos os espécimes foram submetidos à ciclagem mecânica com freqüência de 2 Hz e 500.000 ciclos com carga de 3Kg. Os corpos de prova foram submetidos a teste de compressão em uma máquina universal de ensaios (Emic) com velocidade de carga de 1,0 mm/min até a sua fratura. Os valores de resistência à fratura foram G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. A análise de variância (ANOVA) (p<0,05) mostrou diferença estatisticamente significante para os pinos. Quanto à análise de fratura, os núcleos metálicos fundidos apresentaram o maior número de amostras com fratura desfavoráveis quando comparados os pinos de fibra de quartzo. O conjunto pino de fibra restaurados com coroa metalo cerâmica, apresentou valor de resistência à fratura estatisticamente maior quando comparado aos demais grupos segundo o teste de Tukey (5%), Metalo cerâmica - 64,12±13,69 kgf, difere estatisticamente das demais coroas metal free - 52,59±9,88 kgf e cerômero - 51,20±10,08 kgf que... / The aim of this study was to compare the fracture resistance and failure of maxillary incisors restored using fiber post and metallic post under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of fiber post, metallic post and typo of full coverage crown. Sixty maxillary incisors were divided into 6 groups of 10 each. G1- metallic post + metallic ceramic crowns, G2- metallic post + e-max system, G3- metallic post + cerômeros, G4- Fiber post and accessories post + metallic ceramic crowns, G5- Fiber post and accessories post + e-max system and G6- Fiber post and accessories post + cerômeros. The specimens were submitted a mechanical loading at a frequency of 2 Hz for a total of 500.000 cycles. After were taken to the Universal Test Machine for the fracture resistance at 1,0 mm/min speed. The fracture resistance values were G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. Results show statistically significant differences in relation to the type of the posts (ANOVA) (p<0,05). Fracture analyses about metallic post showed the most unfavorable fracture and fiber post restored with metallic crown showed statistically significant difference in relation to the others groups. Tukey test (5%) showed Metallic-crown - 64,12±13,69 kgf, is statistically difference than the other crowns metal free - 52,59±9,88 kgf and Sinfony crowns - 51,20±10,08 kgf that was not different between itself. The result of this study indicate that the use of fiber posts increase their resistance to fracture and improve the prognosis in case of fracture
5

Influência de dois tipos de retentores intra-radiculares e do tipo de coroa total na resistência e modo de fratura de raízes de incisivos superiores /

Zamboni, Sandra Regina Oliveira Costa. January 2010 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Eduardo Shigueiuki Uemura / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Mauro Antonio de Arruda Nóbilo / Banca: Tarcísio José de Arruda Paes Junior / Resumo: O objetivo neste estudo foi avaliar e comparar a resistência à fratura de incisivos centrais restaurados usando dois tipos de pinos intra-radiculares: núcleo metálico fundido e pinos de fibra de quartzo, reconstruídos com diferentes tipos de coroas. A hipótese nula testada foi que a resistência a fratura desses corpos de prova não apresentariam diferença quanto ao tipo de pino e tipo de coroa. Sessenta incisivos centrais superiores foram divididos em 6 grupos: G1- núcleo metálico fundido + coroa em cerômero, G2- núcleo metálico fundido + coroa metalo-cerâmica, G3- núcleo metálico fundido + coroa em e-max, G4 - pino de fibra de quartzo e pinos acessórios + coroa em cerômero, G5- pino de fibra de quartzo e pinos acessórios + coroa metalo-cerâmica e G6- pino de fibra de quartzo e pinos acessórios + coroa em e-max. Todos os espécimes foram submetidos à ciclagem mecânica com freqüência de 2 Hz e 500.000 ciclos com carga de 3Kg. Os corpos de prova foram submetidos a teste de compressão em uma máquina universal de ensaios (Emic) com velocidade de carga de 1,0 mm/min até a sua fratura. Os valores de resistência à fratura foram G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. A análise de variância (ANOVA) (p<0,05) mostrou diferença estatisticamente significante para os pinos. Quanto à análise de fratura, os núcleos metálicos fundidos apresentaram o maior número de amostras com fratura desfavoráveis quando comparados os pinos de fibra de quartzo. O conjunto pino de fibra restaurados com coroa metalo cerâmica, apresentou valor de resistência à fratura estatisticamente maior quando comparado aos demais grupos segundo o teste de Tukey (5%), Metalo cerâmica - 64,12±13,69 kgf, difere estatisticamente das demais coroas metal free - 52,59±9,88 kgf e cerômero - 51,20±10,08 kgf que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to compare the fracture resistance and failure of maxillary incisors restored using fiber post and metallic post under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of fiber post, metallic post and typo of full coverage crown. Sixty maxillary incisors were divided into 6 groups of 10 each. G1- metallic post + metallic ceramic crowns, G2- metallic post + e-max system, G3- metallic post + cerômeros, G4- Fiber post and accessories post + metallic ceramic crowns, G5- Fiber post and accessories post + e-max system and G6- Fiber post and accessories post + cerômeros. The specimens were submitted a mechanical loading at a frequency of 2 Hz for a total of 500.000 cycles. After were taken to the Universal Test Machine for the fracture resistance at 1,0 mm/min speed. The fracture resistance values were G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. Results show statistically significant differences in relation to the type of the posts (ANOVA) (p<0,05). Fracture analyses about metallic post showed the most unfavorable fracture and fiber post restored with metallic crown showed statistically significant difference in relation to the others groups. Tukey test (5%) showed Metallic-crown - 64,12±13,69 kgf, is statistically difference than the other crowns metal free - 52,59±9,88 kgf and Sinfony crowns - 51,20±10,08 kgf that was not different between itself. The result of this study indicate that the use of fiber posts increase their resistance to fracture and improve the prognosis in case of fracture / Doutor
6

Retenção em canais amplos de núcleos confeccionados por diferentes técnicas com pinos fibro resinosos / Retention of fiber posts made by diferent technics in enlarged root canals

Marcelo Nunes Heimlich 27 April 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O propósito desse trabalho foi verificar a retenção de pinos fibro resinosos cimentados em canais radiculares alargados simulando raízes extensamente comprometidas, fabricados por duas técnicas usadas para diminuir sua desadaptação; comparando-as ao pino fixado somente com cimento. Foram utilizados vinte e quatro raízes de dentes humanos unirradiculares, padronizadas com 15.0 mm de comprimento e 5.0 0.3 mm de diâmetro. As raízes foram incluídas em resina acrílica e divididas em grupos de acordo com a técnica usada: grupo I - pino DC White Post no2 cimentado com sistema adesivo quimicamente ativado e com cimento resinoso dual; grupo II mesmo pino reanatomizado com resina composta para copiar a anatomia do canal radicular, cimentado da mesma forma; e grupo III mesmo pino associado a três pinos acessórios, cimentados do mesmo modo. O canal radicular teve seu diâmetro padronizado pela broca no2 para o pino DC em uma profundidade de 12.0 mm e alargado com uma broca tronco cônica em uma profundidade de 10.0 mm. As oito raízes de cada grupo foram seccionadas transversalmente em três discos de 3.0 mm, a partir da cervical para a execução de um ensaio de extrusão, descartando-se os últimos 2.0 mm, que serviram somente para centralizar o pino. Os valores de retenção foram registrados e tratados estatisticamente por ANOVA e pelo teste SNK (p<0.05). Diferenças significativas foram observadas entre três porções radiculares investigadas em todos os grupos, com os valores de retenção diminuindo da cervical para apical. A retenção na porção apical do grupo com pinos customizado com resina foi estatisticamente maior que na mesma região dos demais grupos. Nenhuma diferença foi encontrada entre o grupo com pinos acessórios e o grupo somente com pino e cimento nessa parte da raiz. Nenhuma diferença foi observada comparando as porções cervical e média dos diferentes grupos. Os tipos de falha após o teste de extrusão foram observados em microscópio eletrônico de varredura com aumento de 200, 600 e 1000 vezes. Elas ocorreram exclusivamente entre o pino e o cimento ou a resina composta. A camada de adesão (camada híbrida) foi mais facilmente observada nas porções cervical e média de todos os grupos. Isso sugere que a retenção nas porções apicais da raiz é predominantemente friccional. Uma vez que pinos acessórios somente alcançam até a porção média do canal radicular, a retenção do pino não é aumentada com essa técnica. / The aim of this study was to evaluate the retention of fiber posts cemented in enlarged root canals simulating compromised roots, fabricated with to two techniques used to minimize your desadptation; comparing it to posts fixed only with ciment. Twenty four single root human teeth standardized in 15.0mm length and 5.0 0.3mm diameter were used. The roots were imbibed in acrylic resin and divided in groups according to the technique used: group I - DC White Post no2 cemented with quimically cured adhesive system and a dual cured resin cement; group II the same post customized with composite resin to copy the root canal anatomy, cemented the same way; and group III the same post associated with three accessory posts, cemented the same way. The root canals had their diameter standardized using a no2 DC post burs 12.0 mm deep and enlarged with a chamfer bur 10.0 mm deep. The eight roots of each group were transversely sectioned in three 3.0 mm diameter discs, starting from cervical to make the push out test, discarding the last 2.0mm used only to centralize the post. The retention values were registered and statistically treated with ANOVA and SNK tests (p<0.05). Significant differences were observed when comparing the three root portions of all groups investigated, with retention values decreasing from cervical to apical. The retention in apical portion of customized posts was statistically greater than the same parts of other groups. No differences were found between the group with accessory posts and only cemented posts in this root portion. No differences was observed comparing cervical e middle portions of different groups. The failure types after the push out test were observed in MEV with 200, 600 e 1000x magnification. They occurred exclusively between the post and the resin cement or the composite resin. A hybrid layer was more easily observed in the cervical and middle portions of the roots in all groups. This suggests that the retention in the apical portions of roots is mostly frictional. Since accessory posts only eventually can reach the middle portion of root canal the post retention is not increased with this technique.
7

Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementation

Ana Paula Ribeiro do Vale Pedreira 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.
8

EFEITO DA APLICAÇÃO SÔNICA DE SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO AO CANAL RADICULAR / Effect of sonic application of adhesive systems on bond strength of fiber posts to root canal

Zarpellon, Driellen Christine 22 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1 Driellen C Zarpellon.pdf: 2067341 bytes, checksum: 353cd12f8d341ee6a474a3f966dbe8e2 (MD5) Previous issue date: 2016-02-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Bonding adhesive systems and luting agents material inside the root canal is still a challenge in luting posts. This study evaluated the effects of applying three bonding agents using a vibrating sonic device on the push-out bond strength (BS) and nanolakage (NI) pattern, when these products were applied in the etch-and-rinse mode to bond fiber post to the root canal. Fifty-four roots of human premolars were endodontically prepared and divided into 6 groups according to combination of the main factors: products (Ambar Universal / AllCem, Single Bond Universal / RelyX ARC, Prime & Bond Elect / Enforce) and application mode (manual or sonic). The fiber posts were cemented and sectioned transversally into six 1-mm thick serial slices, which were subjected to a push-out bond strength test at 0.5 mm/min. In addition, two roots (n=2) were subjected to NI analysis using scanning electron microscopy after immersion of slices in silver nitrate. The data were analyzed by 2-way ANOVA and Bonferroni's post-hoc test (α=5%). Sonic application increased BS significantly only on the coronal third in the Ambar Universal group. When Single Bond Universal was used, higher BS values were observed when the bonding agent was manually applied in comparison to those when the sonic device was used. For Prime & Bond Elect, no significant difference in BS values was noted when the application methods were compared. Manual application also produced lower NI values than sonic application when Ambar Universal was used, while no significant difference in NI was noted when the other adhesive systems were used. The sonic application did not improve the bond strength of posts to root canal in comparison to manual application. / Adesão de sistemas adesivos e agentes de união ao canal radicular ainda é um desafio na cimentação de pinos. Este estudo avaliou os efeitos da aplicação de três agentes de união universais usando dispositivo de vibração sônica na resistência de união por push-out (RU) e padrão de nanoinfiltração (NI), quando esses produtos foram aplicados no modo convencional na adesão de pinos de fibra de vidro ao canal radicular. Raízes de 54 pré-molares humanos foram preparadas endodonticamente e divididas em 6 grupos de acordo com a combinação dos fatores principais: produtos (Ambar Universal / AllCem, Single Bond Universal / RelyX ARC, Prime & Bond Elect / Enforce) e modo de aplicação (manual ou sônico). Os pinos de fibra de vidro foram cimentados e seccionados transversalmente em 6 fatias de 1mm de altura, as quais foram submetidas ao teste de RU por push-out a uma velocidade de 0,5 mm/min. Além disso, duas raízes (n=2) foram submetidas à análise de NI usando microscópio eletrônico de varredura após imersão em nitrato de prata. Os dados foram analisados por ANOVA 2 fatores e teste de Bonferroni (α=5%). A aplicação sônica aumentou significativamente a RU apenas no terço coronal do grupo Ambar Universal. Quando o Single Bond Universal foi usado, valores mais altos de RU foram observados quando o agente de união foi aplicado manualmente em comparação aos valores quando o dispositivo sônico foi usado. Para o Prime & Bond Elect, nenhuma diferença significativa na RU foi observada na comparação entre métodos. Aplicação manual também produziu valores mais baixos de NI que aplicação sônica quando Ambar Universal foi usado, enquanto nenhuma diferença na NI foi observada nos outros sistemas de adesivos usados. A aplicação sônica não melhorou a adesão de pinos ao canal radicular comparado a aplicação manual.
9

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

Cardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
10

AVALIAÇÃO DE PROPRIEDADES DE UNIÃO DE ADESIVOS UNIVERSAIS AO CANAL RADICULAR PREPARADO COM DIFERENTES INSTRUMENTOS ROTATÓRIOS / Evaluation of bonding properties of universal adhesives to root canal prepared with different rotary instruments

Bakaus, Thaís Emanuelle 16 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1 Thais Bakaus.pdf: 1611331 bytes, checksum: 4d80c0ed64cbca5d883bbdad39b16c0d (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of this study was to evaluate the influence of a rotating device used to prepare the root canal in the adhesion of glass fiber posts and evaluate different bonding strategies using universal adhesive systems. One hundred human premolars were used, which had their crowns removed and their roots endodontically treated. Initially, the roots were divided into four groups, according to a combination of the factors: a rotating device used to prepare the root canal - carbide bur (CB) and diamond bur (DB) and cementation system (universal adhesive system associated with its respective resin cement - Single Bond Universal / RelyX ARC (SB) and Prime&Bond elect / Enforce (PB). They were then divided into subgroups according to the bonding strategy: Self-etch (SE) or Etch-and-rise (E&R). Eight teeth per group were evaluated in bond strength (BS) by the push-out test and 4 in nanoleakage teeth (NL) by scanning electron microscopy (SEM), and the roots for these tests were transversely sectioned in 6 slices. The data of BS and NI for each cementation system were subjected to 2-way ANOVA and Tukey (α = 0.05). For BS, only the major factors were significant (p <0.05), and for both cementation systems, the highest BS values were observed for the preparation with DB compared to the CB and SE adhesion strategy compared with E&R. Likewise, the interaction was not significant for NL (p> 0.05). For the cementation system PB, the lowest values were observed for groups using DB compared to the CB and SE adhesion strategy compared to E&R. For the SB cementation system, only the rotating device main factor was significant (p = 0.01), whereas the DB resulted in lower average nanoleakage compared to the CB. It can be concluded that to improve the adhesion of glass fiber posts to root canal, diamond bur should be used to prepare the root canal; and, in general, universal adhesive systems must be used in self-etch mode to obtain satisfactory results on intracanal adhesion. / Avaliou-se a influência do instrumento rotatório utilizado para preparo do conduto radicular na adesão de pinos de fibra de vidro e diferentes estratégias de adesão utilizando sistemas adesivos universais. Foram utilizados 100 pré-molares inferiores humanos, os quais tiveram suas coroas removidas e suas raízes tratadas endodonticamente. Inicialmente, as raízes foram divididas em quatro grupos, de acordo com a combinação dos seguintes fatores: instrumento rotatório utilizado para preparo do conduto radicular - broca carbide (BC) e ponta diamantada (PD) e sistema de cimentação (sistema adesivo universal associado com seu respectivo cimento resinoso) - Single Bond Universal/RelyX ARC (SB) e Prime&Bond elect/Enforce (PB). Foram divididos então em subgrupos de acordo com a estratégia de adesão: Self-etch (SE) ou Etch-and-rinse (E&R). Oito dentes por grupo foram avaliados em resistência de união (RU) pelo teste de push-out e 4 dentes em nanoinfiltração (NI) por microscopia eletrônica de varredura (MEV), sendo que para esses testes as raízes foram seccionadas transversalmente em 6 fatias. Os dados de RU e NI para cada sistema de cimentação foram submetidos à ANOVA 2 fatores e Tukey (α=0,05). Para RU, apenas os fatores principais foram significativos (p < 0,05), sendo que para ambos os sistemas de cimentação maiores valores de RU foram observados para o preparo radicular com PD em comparação com a BC e para a estratégia de adesão SE comparada a E&R. Da mesma maneira, a interação não foi significativa para NI (p > 0,05). Para o sistema de cimentação PB menores valores foram observados para os grupos que utilizaram PD em comparação com a BC e para a estratégia de adesão SE em comparação com a E&R. Para o sistema de cimentação SB, apenas o fator principal instrumento rotatório foi significante (p = 0,01), sendo que a PD resultou em menores médias de nanoinfiltração em comparação com a BC. Pode-se concluir que para melhorar a adesão de pinos de fibra de vidro ao canal radicular pontas diamantadas devem ser utilizadas para o preparo do conduto radicular; e, de maneira geral, os sistemas adesivos universais devem ser utilizados na maneira self-etch para obterem resultados satisfatórios de adesão intracanal.

Page generated in 0.4556 seconds