• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 24
  • 23
  • 17
  • 17
  • 16
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência do sistema de cimentação e do modo de ativação na resistência ao push-out de pinos de fibra de vidro / Influence of cementation system and activation mode on push-out bond strength of glass fiber posts

Reinaldo de Souza Ferreira 04 December 2009 (has links)
O objetivo deste estudo foi avaliar a influência do tipo de sistema de cimentação (condicionamento ácido total ou autoadesivo), do modo de ativação (autoativado ou dual), do terço do conduto radicular (cervical, médio ou apical) e da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro cimentados em dentes humanos. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Decorridos sete dias, os condutos foram preparados a uma profundidade de 10mm com brocas padronizadas do sistema dos pinos de fibra (WhitePost DC #2) e aleatoriamente divididos em 4 grupos, conforme o sistema de cimentação e o modo de ativação: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (condicionamento ácido total), ativação dual, (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, autoativado, (G3) RelyX U100 (autoadesivo), dual e (G4) RelyX U100, autoativado. Após uma semana, cada raiz foi seccionada em máquina de corte, originando 6 fatias de 1 mm de espessura (n=60). Antes do ensaio de push-out cada fatia foi fotografada em ambas as faces, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram capturadas para determinação do modo de falha. Para automatizar a determinação da espessura de cimento, foi desenvolvida uma macro no software KS 400. Os dados foram estatisticamente analisados com ANOVA 3 fatores (resistência de união) e teste de Kruskall-Wallis (espessura do cimento). Comparações múltiplas foram realizadas com o teste Student-Newman-Keuls. Análise de regressão, modelo linear, foi empregada para verificar a correlação entre espessura do cimento e resistência de união. Todos os testes foram aplicados com &#945; = 0,05. O fator cimento exerceu influência significativa para a resistência de união (p = 0,0402): o RelyX U100 apresentou a maior média. A ativação dual elevou os valores de resistência de união em comparação ao modo quimicamente ativado (p < 0,0001). Houve diferenças significantes entre os grupos, sendo G1 (22,4 4,0 MPa) > G3 (20,4 3,6 MPa) > G4 (17,8 5,2 MPa) > G2 (13,5 4,3 MPa). O terço do conduto não exerceu influência significativa sobre a resistência adesiva (p = 0,4749). As espessuras dos filmes de cimento foram estatisticamente diferentes nos diferentes terços: cervical (102 45 m) > médio (75 29 m) > apical (52 28m). Não foi observada forte correlação entre os valores de espessura e os de resistência ao push-out (r = - 0,2016, p = 0,0033). O tipo de falha predominante foi a mista, exceto para o G2, que apresentou 74% das falhas na interface cimento-pino. Dessa forma, o cimento autoadesivo apresentou melhor desempenho que o convencional, e ambos os sistemas duais, sobretudo o RelyX ARC, apresentaram dependência da fotoativação para atingirem maiores valores de resistência de união. / The aim of this study was to evaluate the influence of adhesive cementation system approach (total-etch or self-adhesive), activation mode (self-cure or dual-cure), canal third (cervical, middle or apical) and cement thickness on push-out bond strength of glass fiber post bonded on human roots. Forty roots were embebed in epoxy resin and endodontically treated (filled with guta percha and non-eugenol endodontic sealer). Following 7 days, the post spaces were prepared with low-speed post drills provided by the manufacturer (WhitePost DC #2, FGM) at a depth of 10 mm and the roots were randomly divided in 4 groups, according to cementation system and activations mode: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (total-etch), dual-cure (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, self-cure, (G3) RelyX U100 (self-adhesive), dual-cure and (G4) RelyX U100, self-cure. After 7 days, each root was sectioned with water-cooled diamond blade, generating six 1-mm thickness slices (n=60). Before push-out bond strength test, digital images of both sides of the slices were captured with digital camera, in order to measure the post radius and the cement thickness. After mechanical test, new images were captured to evaluate the failure mode. A macro was developed in KS 400 software to speed and standardize the evaluation of cement thickness. Results were analyzed using three-way ANOVA (push-out) and Kruskall-Wallis test (cement thickness). Post-hoc multiple comparisons were performed using the Student-Newman-Keuls test. The correlation between resin cement thickness and bond strength was evaluated with regression analysis, linear model. All tests were performed with significance level set at 0.05. Push-out bond strength was significantly influenced by cement type (p= 0.0402): the RelyX U100 cement presented higher mean value. The dual-activated mode increased the bond strength in comparison to self-activated mode (p < 0.0001). Statically differences were observed between groups: G1 (22.4 4.0 MPa) > G3 (20.4 3.6 MPa) > G4 (17.8 5.2 MPa) > G2 (13.5 4.3 MPa). Bond strength was not affected by post space depth (p = 0,4749). The resin cement thicknesses were significantly different in root thirds: cervical (102 45 m) > middle (75 29 m) > apical (52 28m). No strong correlation between cement thickness and push-out bond strength was observed (r = - 0.2016, p = 0.0033). The main failure mode was mixed, except for G2 (74% adhesive failures at post-cement interface). It was concluded tha the self-adhesive cement showed a better performance than the conventional one, and both dual resin systems, specially the RelyX ARC, presented photo-activation dependence to attain greater adhesive bond strength.
Read more
22

Resistência de união de cimentos resinosos à dentina previamente submetida a radioterapia / Bonding strength of resin cements to the dentin previously submitted to radiotherapy

Paulo André Yamin 02 February 2017 (has links)
Este estudo avaliou, in vitro, a influência da radioterapia na resistência de união (RU) e na interface adesiva entre diferentes cimentos resinosos e dentina radicular. Sessenta caninos superiores foram distribuídos em 2 grupos (n=30) de acordo com a irradiação: não irradiados e irradiados. Os dentes do grupo irradiado foram submetidos à radioterapia com raios-X de 6 MV em frações de 2 Gy, com 30 ciclos, perfazendo 60 Gy. Os dentes foram seccionados para obtenção de raízes com 16 mm de comprimento, sendo realizado em seguida o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento a base resina epóxica. Cada grupo foi subdividido de acordo com o cimento resinoso utilizado para a cimentação dos pinos de fibra de vidro (n=10): RelyX U200; Panavia F 2.0; RelyX ARC. Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados de acordo com as recomendações de cada fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 3 slices de cada terço da raiz. Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface cimento/dentina em MEV com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos à análise estatística pelos testes de ANOVA e Tukey, e Kruskal-Wallis e Duns, respectivamente. Os espécimes irradiados apresentaram menores valores de RU (8,23&plusmn;4,26) comparados aos dentes não irradiados (11,88&plusmn;6,42) (p<0,00001). Quanto aos cimentos resinosos, o RelyX U200 apresentou maiores valores na RU (15,17&plusmn;5,89) comparado aos cimentos RelyX ARC (7,68&plusmn;4,22) (p<0,0001) e Panavia F 2.0 (7,32&plusmn;2,71) (p<0,0001). O terço cervical apresentou maiores valores de RU (13,08&plusmn;6,10) comparado aos terços médio (9,72&plusmn;5,03) e apical (7,38&plusmn;4,53) (p<0,0001). O padrão de falhas mostrou ocorrência de falhas coesivas na dentina para os espécimes irradiados. Na análise da interface cimendo/dentina por MEV, observou-se maior desadaptação nos dentes submetidos à radioterapia. Em relação aos cimentos resinosos, foi observada maior adaptação com RelyX U200 e RelyX ARC comparados à Panavia F 2.0. Na análise qualitativa em MEV observou-se presença de fraturas e microfraturas na dentina radicular e menor presença de fibras colágenas em dentes irradiados. Para o cimento resinoso RelyX U200 e Panavia F 2.0 observou-se interface justaposta do cimento com a dentina radicular em dentes irradiados e não irradiados, sendo que para o cimento resinoso RelyX ARC foi observada formação de camada híbrida e tags de maneira similar para dentes irradiados e não irradiados. Concluiu-se que a radioterapia resultou na redução da resistência de união e na maior desadaptação da interface cimento resinoso/dentina radicular e que o cimento resinoso autoadesivo se apresentou como melhor alternativa para cimentação de pinos de fibra de vidro em dentes irradiados. / This in vitro study, evaluated the influency of radiotherapy on bond strength (BS) and adhesive interface between different resin cements and root dentin. Sixty maxillary canines were selected and distributed into two groups (n = 30) according to the irradiation protocol: non-irradiated and irradiated. The irradiated group were submitted to X-ray radiotherapy of 6 MV in fractions of 2 Gy, with 30 cycles, until complete 60 Gy. The teeth were sectioned to obtain 16 mm of root length, followed by biomechanical preparation with R50 reciproc instrument and obturation using the lateral condensation technique with epoxy resin-based sealer. Then, each group was subdivided according to the resin cement used for the glass fiber post cementation (n = 10): RelyX U200, Panavia F 2.0 and RelyX ARC. The posts were submitted to surface treatment with 10% hydrofluoric acid, and then cemented according to the manufacturer instructions. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, and 3 slices were obtained from each root third. The most cervical slice of each third was used to evaluate the BS by the push-out test at 0.5 mm/min of velocity and the failure pattern was analyzed using stereomicroscopy. The most apical slice of each third was selected for SEM analysis, which were prepared and metalized. The dentin/cement interface analysis was performed at the following magnification: 100, 1000, 2000 and 4000X. The BS data and dentin/cement interface adaptation were submitted to statistical analysis by ANOVA, Tukey and Kruskal-Wallis, and Duns tests respectively. The irradiated specimens had lower BS values (8.23 &plusmn; 4.26) compared to non-irradiated group (11.88 &plusmn; 6.42) (p <0.00001). Regarding the resin cements, the RelyX U200 showed the higher values in BS (15.17 &plusmn; 5.89) compared to RelyX ARC (7.68 &plusmn; 4.22) and Panavia F 2.0 (7 , 32 &plusmn; 2.71) (p <0.0001). In addition, the cervical third presented higher BS values (13.08 &plusmn; 6.10) when compared to the middle (9.72 &plusmn; 5.03) and apical (7.38 &plusmn; 4.53) thirds (p <0.0001). The failure pattern showed cohesive failures in root dentin of the irradiated specimens. In the SEM dentin/cement interface analysis, a greater misadaptation was observed for the teeth submitted to radiotherapy. Regarding the resin cements, a better adaptation was observed for the RelyX U200 and RelyX ARC compared to the Panavia F 2.0. In the SEM qualitative analysis of the irradiated teeth, was possible to observe the presence of fractures and microfractures in the root dentin and a small number of collagen fibers. The resin cements RelyX U200 and Panavia F 2.0 showed a juxtaposed interface of the cement with the root dentin in irradiated and non-irradiated teeth, being that for the RelyX ARC cement the presence of hybrid layer and tags was similar for irradiated and non-irradiated groups. It was concluded that the radiotherapy promoted reduction of the bond strength and increase the gaps in the dentin/resin cement interface and the self-adhesive resin cement is the best alternative for glass fiber posts cementation in irradiated teeth.
Read more
23

AvaliaÃÃo da resistÃncia de uniÃo da interface adesiva de pinos de fibra de vidro e a dentina radicular / Bond strength at the adhesive interface of fiber glass posts and root dentin

Aminthas Alves Brasil Neto 30 March 2007 (has links)
nÃo hà / O objetivo deste trabalho foi avaliar a resistÃncia de uniÃo da interface adesiva de pinos de fibra de vidro e dentina radicular, em trÃs regiÃes do conduto, fixados com trÃs sistemas de cimentaÃÃo. Vinte e quatro dentes humanos hÃgidos, recÃm-extraÃdos por razÃes ortodÃnticas ou periodontais, tiveram suas coroas removidas na junÃÃo cemento-esmalte com um disco diamantado, sob irrigaÃÃo. As raÃzes receberam tratamento endodÃntico e foram obturadas com guta-percha e um cimento endodÃntico contendo eugenol (Endofil). A desobstruÃÃo foi realizada uma semana apÃs o tÃrmino do tratamento endodÃntico em uma profundidade de 9 mm medida da regiÃo cervical da raiz. O pino (Reforpost Fibra de Vidro n 3) foi cimentado no conduto radicular com um dos trÃs sistemas de fixaÃÃo descritos a seguir (n = 8): no grupo 1 foi utilizado o sistema Single Bond 2/ RelyX ARC, no grupo 2 foi utilizado o sistema ED Primer/Panavia 21 e no grupo 3 foi utilizado o cimento RelyX Unicem. Todos os cimentos e sistemas adesivos foram utilizados de acordo com as instruÃÃes dos fabricantes. Posteriormente, as raÃzes foram seccionadas em uma mÃquina de corte, sob irrigaÃÃo, em trÃs porÃÃes, correspondentes aos terÃos cervical, mÃdio e apical da regiÃo do conduto preparada para o pino. Os espÃcimes foram submetidos ao teste de extrusÃo por cisalhamento (âpush-outâ) em uma mÃquina de ensaio universal a uma velocidade de 0,5 mm/min e os valores de resistÃncia de uniÃo mÃxima foram registrados e submetidos à anÃlise estatÃstica (p < 0,05). A anÃlise de variÃncia (ANOVA) mostrou diferenÃa estatÃstica significante entre os terÃos (cervical, mÃdio e apical) somente para o grupo do cimento Panavia 21, no qual o terÃo apical apresentou menor mÃdia de resistÃncia de uniÃo do que os terÃos cervical e mÃdio (teste de Tukey). Quando se comparou a resistÃncia de uniÃo em cada regiÃo da raiz, avaliando-se os materiais de cimentaÃÃo, a anÃlise de variÃncia (ANOVA) mostrou diferenÃa estatÃstica significante para as trÃs regiÃes do conduto. Para os terÃos mÃdio e apical, o cimento Panavia 21 apresentou mÃdia de resistÃncia de uniÃo significativamente menor do que os cimentos Single Bond 2/RelyX ARC e RelyX Unicem, sendo estes estatisticamente iguais entre si. Para o terÃo cervical, o cimento RelyX Unicem apresentou maiores valores de resistÃncia de uniÃo do que o cimento Panavia 21, tendo sido o cimento Single Bond 2/RelyX ARC estatisticamente semelhante aos outros dois materiais / The aim of this study was to assess the bond strength at the adhesive interface of fiber glass posts and root dentin, in three regions of the canal, fixed with three cementation systems. Twenty-four healthy human teeth, recently extracted for orthodontic or periodontal reasons, had their crowns removed at the cement-enamel junction with a diamond disk, under irrigation. The roots were endodontically treated and were filled with gutta percha and an endodontic cement containing eugenol (Endofil). One week after endodontic treatment ended, the obstruction was removed at a mean depth of 9mm in the cervical region of the root. The posts (Reforpost Fibra de Vidro No. 3) were cemented in the canals prepared with one of the three fixation systems described as follows (n = 8): in group 1 the Single Bond 2/ RelyX ARC system was used; in group 2 the ED Primer/Panavia 21 system, and in group 3 RelyX Unicem cement was used. All the cements and adhesive systems were used in accordance with the manufacturersâ instructions. Afterwards, the roots were sectioned in a cutting machine under irrigation, into three portions corresponding to the cervical, middle and apical thirds of the root canal region prepared for the post. The specimens were submitted to the pushout test in a universal test machine at a speed of 0.5 mm/min and the maximum bond strength values were recorded and submitted to statistical analysis (p < 0.05). Analysis of variance (ANOVA) showed statistically significant difference between the cervical, middle and apical thirds only for the Panavia 21 cement group, in which the apical third presented a lower mean bond strength value than the cervical and middle thirds (the TukeyÂs test). When the bond strength in each region of the root was compared to assess the cementing materials, the analysis of variance (ANOVA) showed statistically significant different for the three regions of the canal. For the middle and apical thirds, the Panavia 21 cement presented significantly lower mean bond strength than the Single Bond 2/RelyX ARC and RelyX Unicem cements, these being statistically equal between them. For the cervical third, RelyX Unicem cement presented higher bond strength values than the Panavia 21 cement and the Single Bond 2/RelyX ARC cement was statistically equal to the other two materials
Read more
24

EFEITO DE DIFERENTES SOLUÇÕES IRRIGADORAS SOBRE A RESISTÊNCIA ADESIVA DE PINOS DE FIBRA DE VIDRO COM UTILIZAÇÃO DE CIMENTO AUTOADESIVO / NEGATIVE INFLUENCE OF DIFFERENT IRRIGANTS ON BOND STRENGH OF FIBER POSTS CEMENTED WITH A SELF-ADHESIVE CEMENT

Seballos, Vívian Gehm 25 July 2016 (has links)
The purpose of this study is to evaluate the effect of different irrigatins on bond strength of fiber posts cemented with RelyX U200. Eighty single-rooted premolars were sectioned at 14 mm from the apex, prepared with ProTaper Universal system until F3 instrument, and filled with F3 master cone and AH Plus sealer. Root canal filling was partially removed, remaining 4 mm of guta-percha at the apical third. Specimens were randomly divided into 8 groups (n=10), according to the irrigant used during root canal preparation and before fiber post cementation (dentin surface treatment), as described: SS: 0,9% saline solution (control group); CHX: 2% chlorhexidine; 1%NaOCl: 1% sodium hypochlorite; 2,5%NaOCl: 2,5% sodium hypochlorite; 5%NaOCl: 5% sodium hypochlorite; 1%CaOCl: 1% calcium hypochlorite; 2,5%CaOCl: 2,5% calcium hypochlorite; e 5%CaOCl: 5% calcium hypochlorite. For each group, irrigation was performed continuously with 2ml. Exacto N2 glass fiber posts were cemented with RelyX U200. The specimens were sectioned providing 3 slices, one for each root third and the push-out test was performed. Optical microscopy was used to analyze the failure mode. Bond strength means were calculated and ANOVA and Bonferroni tests were used for statistical analysis. SS showed higher mean of bond strength values (11.47MPa), than all NaOCl and CaOCl groups, which showed similar values to CHX (7.56Mpa ± 2:47). Adhesive failures at cement/dentin interface were predominant (58.33%). NaOCl and CaOCl negatively affect the bond strength of fiber posts to root dentine when cemented with sef-adhesive resin cement; however the concentration of NaOCl and CaOCl did not affect this outcome. / Este estudo tem como objetivo avaliar o efeito de diferentes soluções irrigadoras sobre a resistência adesiva de pinos de fibra de vidro, cimentados com cimento autoadesivo RelyX U200. Foram utilizados 80 pré-molares inferiores humanos tiveram a coroa seccionada, padronizando-se o comprimento da raiz em 14 mm. Os condutos foram instrumentados com o sistema rotatório ProTaper até o instrumento F3, obturados com cimento endodôntico AH Plus e cones de guta-percha F3 do mesmo sistema, pela técnica do cone único. Os condutos foram desobturados até 10mm de profundidade, mantendo-se os 4mm apicais da obturação. As raízes foram aleatoriamente distribuídas em 8 grupos (n=10), de acordo com a solução irrigadora utilizada previamente à cimentação dos pinos: SS: solução salina 0,9% (grupo controle); CHX: clorexidina 2%; 1%NaOCl: hipoclorito de sódio 1%; 2,5%NaOCl: hipoclorito de sódio 2,5%; 5%NaOCl: hipoclorito de sódio 5%; 1%CaOCl: hipoclorito de cálcio 1%; 2,5%CaOCl: hipoclorito de cálcio 2,5%; e 5%CaOCl: hipoclorito de cálcio 5%. Para cada espécime, a irrigação foi realizada com 2ml da solução a cada troca de instrumento. Os pinos de fibra de vidro do Sistema Exacto Translúcido n02 foram silanizados e cimentados com o cimento resinoso autoadesivo RelyX U200. As raízes foram seccionadas na máquina de corte, de forma a obter 3 slices por espécime, sendo 1 slice para cada terço radicular. A seguir, os corpos de prova foram submetidos ao teste de push-out na máquina de ensaio universal EMIC. Para análise do padrão de falha, os espécimes foram analisados com microscopia óptica. A média de resistência adesiva de cada espécime foi calculada. Testes ANOVA e Bonferroni foram utilizados para analisar as diferenças entre os grupos. O grupo SS demonstrou a maior média de resistência adesiva, sendo superior aos grupos NaOCl e CaOCl (P <0.05), nos quais apresentaram valores semelhantes ao grupo CHX (7.56Mpa ± 2.47). As falhas adesivas cimento/dentina foram predominantes (58.33%). Concluímos que SS parece ser a solução mais adequada para limpeza do canal radicular previamente à cimentação de pinos de fibra cimentados com cimento autoadesivo RelyX U200. NaOCl e CaOCl diminuíram os valores de resistência adesiva dos pinos de fibra à dentina radicular e suas diferentes concentrações não afetaram este resultado.
Read more
25

INFLUÊNCIA DA ADAPTAÇÃO DE PINOS DE FIBRA E DE TÉCNICAS RESTAURADORAS ALTERNATIVAS PARA PREENCHIMENTO DE CANAIS RADICULARES EXCESSIVAMENTE ALARGADOS / Influence of fiber posts adaptation and alternative restorative techniques for flared root canal filling

Gomes, Giovana Mongruel 20 September 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1 Giovana Mongruel Gomes.pdf: 3752517 bytes, checksum: 6acad02e468853d81d1d9172fd003844 (MD5) Previous issue date: 2013-09-20 / The objectives of this study were 1) to evaluate the effect of the influence of the resin cement thickness (RCT) on bond strength (BS) and gap formation (GF) between glass fiber post (FP) and root dentin and 2) to evaluate the BS and fracture resistance (FR) of restorative techniques for filling oversized root canals. In experiment 1, the roots of 24 mandibular premolars (n=8 per group) were endodontically treated. After one week, the post spaces were prepared depending on the post adaptation inside the root canal, simulating an ideal adaptation (IdAd),medium adaptation (MeAd) and inadequate adaptation (InAd). All posts were cemented with Excite® DSC and Variolink® II. After a week of cementation, the RCT and GF were measured with the Image Tool software version 3.0, and the BS by the push-out test. In experiment 2, the roots of 84 mandibular premolars were endodontically treated and, after a week, the conduits were prepared in order to simulate an oversized root canal, except for the positive control group (PC), which was cemented one prefabricated fiber post (PFP) with the diameter compatible with the conduit. In the other oversized root canals, alternative restorative techniques for filling root canals were tested: NC - negative control (PFP with a smaller diameter than of the root canal), PA - PFP + accessory posts, DAP – direct anatomical post,IAP – indirect anatomical post and RR – root reinforcement with composite resin. All posts were cemented with the same adhesive system and resin cement. After indirect composite crowns cementation, the teeth were submitted to mechanical fatigue (1.2 X 106 cycles, 40 N) before the push-out BS test (n=8) and the FR test (n=6). The data of experiments 1 and 2 were analyzed by ANOVA and paired test (α=0.05). The experiment 1 showed that the smaller RCT resulted in better fiber post adhesion, that is, higher BS and lower GF. The experiment 2 showed that the use of direct and indirect anatomical posts resulted in the best performance both in BS and FR tests,and must be the first choice for FP cementation in flared roots with oversized root canals. Therefore, we concluded that the post adaptation to root canal affected significantly its retention. The better the post adaptation, the better the laboratory results. However, in the absence of this ideal condition, the use of direct and indirect anatomic posts should be the first choice for restoring flared root canals. / Os objetivos deste estudo foram 1) avaliar o efeito da influência da espessura de cimento resinoso (ECR) na resistência de união (RU) e na formação de gaps (FG) entre pino de fibra de vidro (PFV) e dentina radicular e 2) avaliar a RU e resistência à fratura (RF) de técnicas restauradoras para preenchimento de canais radiculares excessivamente alargados. No experimento 1, as raízes de 24 pré-molares inferiores (n=8 por grupo) foram tratadas endodonticamente. Após uma semana, os condutos foram preparados em função da adaptação do pino no canal radicular, simulando uma adaptação ideal (AdId), média (AdMe) e inadequada (AdIn). Todos os pinos foram cimentados com Excite® DSC e Variolink® II. Uma semana após a cimentação, a ECR e a FG foram mensuradas com o software Image Tool versão 3.0 e a RU por meio do teste de push-out. No experimento 2, as raízes de 84 pré-molares inferiores foram tratadas endodonticamente e, após uma semana, realizou-se o preparo dos condutos, de maneira a simular um canal radicular excessivamente alargado, com exceção do grupo controle positivo (GCP), em que foi cimentado um pino préfabricado (PPF) com calibre compatível ao diâmetro do conduto. Nos outros condutos alargados, técnicas restauradoras alternativas de preenchimento dos canais radiculares foram empregadas: GCN – grupo controle negativo (PPF de diâmetro inferior ao conduto), GPA – PPF + pinos acessórios, GAD – pino anatômico direto, GAI – pino anatômico indireto e GRR – reforço radicular com resina composta + PPF. Todos os pinos foram cimentados com o mesmo sistema adesivo e cimento resinoso. Após cimentação de coroas de resina indireta, os dentes foram submetidos à fadiga mecânica (1,2 x 106 ciclos, 40 N) antes de realizar o teste de RU (n=8) e de RF (n=6). Os dados do experimento 1 e 2 foram analisados por ANOVA e teste pareado (α=0,05). O experimento 1 mostrou que quanto menor a ECR melhor a adesão dos PFV, ou seja, maior a RU e menor a FG. O experimento 2 mostrou que o uso de pinos anatômicos diretos e indiretos mostrou o melhor desempenho nos testes de RU e RF, e deve ser primeira opção para cimentação de PFV em canais radiculares alargados. Portanto, foi evidenciado que a adaptação do pino ao conduto radicular influenciou significativamente na retenção dos mesmos; quanto mais justa,melhores resultados laboratoriais. Entretanto, na ausência desta condição ideal, o uso de pinos anatômicos diretos e indiretos pode ser a primeira escolha do clínico para tratamento de canais excessivamente alargados. Palavras-chave: cimentos resinosos, dentina radicular, gap, microscopia eletrônica de varredura, pinos de fibra, raízes enfraquecidas, resistência à fratura, resistência de união.
Read more
26

EFEITO DA APLICAÇÃO SÔNICA DE SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO NO CANAL RADICULAR / EFFECTS OF SONIC APPLICATION OF ADHESIVE SYSTEMS ON BONDING FIBER POSTS TO ROOT CANALS

Sánchez, Johanna Lizbeth Cuadros 26 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 Johanna Lizbeth Cuadros Sanchez.pdf: 3888267 bytes, checksum: abbdebf22c3a3a8b49c91f6bc734b34d (MD5) Previous issue date: 2014-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Abstract: Luting of posts inside the root canal is still a challenge because of the difficult to bonding mainly in the apical third. The aim of this study was evaluate the influence of the application of 3 simplified total-etch adhesive systems (Adper Single Bond 2 Ambar, and XP-Bond+self-cure activator) under manual mode or sonic vibration on the push-out bond strength (POBS), silver nitrate uptake (SNU) and in situ degree of conversion (ISDC) associated to resin cement when used for luted posts. Methods: The roots of 66 human premolars were prepared and divided into six groups (n=11), according to the following combination: adhesive and application mode. The posts were cemented in accordance with the manufacturer’s instructions of each cementation system. After water storage, the roots were sectioned transversely into six slabs and it were tested in POBS (0.5mm/min). Two roots for group were data were immersed in 50% silver nitrate, photo-developed and analyzed by SEM to measure the SNU. Two roots for group were evaluated by micro-Raman spectroscopy to measure ISDC. The data were analyzed by 3-way repeated measures ANOVA and Tukey's tests (5%). Results: When sonic application was performed, usually there are a significantly increasing on the POBS (MPa) (35% and 37% respectively) and ISDC (%) (14% and 38% respectively in the medium and apical thirds) and decreasing of SNU (%) for all groups mainly in the medium (64% decreasing) and apical (84%) thirds when compared with manually application (P < 0.05). / Resumo: A cimentação de pinos dentro do canal radicular ainda é um desafio por causa das dificuldades relativas à adesão, principalmente no terço apical. O objetivo deste estudo foi avaliar a influência da aplicação de três sistemas adesivos convencionais simplificados (Adper Single Bond 2, Ambar e XP-Bond + self cure ativator) manualmente ou através de um dispositivo sônico vibratório na resistência de união por push-out (RU), na infiltração de nitrato de prata (NI) e no grau de conversão in situ (GC) associado ao cimento resinoso de cada fabricante, quando utilizado para cimentação de pinos. Métodos: As raízes de 66 pré-molares humanos foram preparadas e divididas em seis grupos (n = 11), de acordo com a seguinte combinação: adesivo/cimento e modo de aplicação. Os pinos foram cimentados de acordo com as instruções do fabricante de cada sistema de cimentação apenas variando o modo de aplicação. Depois do armazenamento em água, as raízes foram seccionadas transversalmente em seis fatias e foram testados em RU (0,5 mm/min). Duas raízes por grupo foram imersas em 50% de nitrato de prata, e após revelação, foram analisadas por MEV para medir a NI. Duas raízes por grupo foram avaliadas por espectroscopia de micro-Raman para medir GC. Os dados foram analisados por análise de variância de 3 fatores de medidas repetidas (terço radicular) e teste de Tukey (5%). Resultados: Quando a aplicação sônica vibratória foi utilizada, em geral, se observou um aumento significativo na RU (MPa) (35% e 37% respectivamente) e GC (%) (14% e 38% respectivamente nos terços médio e apical) e diminuição da NI (%) para todos os grupos, principalmente nos terços médio (redução de 64%) e apicais (84%) quando comparada com a aplicação manual (p <0,05) e este fenômeno ocorreu para todos os sistemas adesivos/cimentos testados.
Read more
27

Efeito do tipo de cimento de fixação e configurações de retentores intra-radiculares na adesão à dentina radicular em diferentes profundidades

Pereira, Janaina Carla 21 August 2007 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / This study evaluated the effect of different types of luting cement and post configuration on the bonding to intra-radicular dentin in different depths. One hundred and twenty roots received endodontic treatment and were post space preparation for fixation of glass fiber post in the configurations: serrated/parallel Reforpost X-Ray (S); and smooth/conical Exato Cônico (L). The posts were fixed with cements: RelyX ARC (ARC), RelyX Luting 2 (LU), RelyX Unicem (UN), Maxicem (MAX) and Cement-Post (CP). The roots were sectioned transversally, getting two disks of 1mm of thickness for third of the root portion: cervical (C), medium (M) and apical (A), and submitted to the micropush-out test with speed of 0.5mm/min. The bond strength values (MPa) were submitted to the analysis of variance in scheme of subdivided parcel and Tukey test (p0.05). There was significant difference among the cements types (p<0.0001), among the localizations (p<0.0001) and the interaction cement x localization was significant (p<0.0001). The post configuration did not influence the bond strength values. The cements LU and UN presented the highest values of bonding in all extension of root dentin. The cements ARC and CP presented similar bonding values in cervical third, however, the bond strength decreased in the crown-apex direction for the ARC. The cement MAX presented the lowest values of bonding. / Este estudo avaliou o efeito do tipo de cimento de fixação e da configuração de retentores intra-radiculares na adesão à dentina intra-radicular em diferentes profundidades. Cento e vinte raízes receberam tratamento endodôntico e foram aliviadas para fixação de retentores intra-radiculares de fibra de vidro nas configurações: serrilhado/paralelo Reforpost X-Ray (S); e liso/cônico Exato Cônico (L). Os pinos foram fixados com cimentos: RelyX ARC (ARC), RelyX Luting 2 (LU), RelyX Unicem (UN), Maxicem (MAX) e Cement-Post (CP). As raízes foram seccionadas transversalmente, obtendo-se 2 discos de 1mm de espessura por terço da porção radicular aliviada: cervical (C), médio (M) e apical (A), e submetidos ao teste de micropush-out com velocidade de 0,5mm/min. Os valores de resistência adesiva (MPa) foram submetidos à análise de variância em esquema de parcela subdividida e teste de Tukey (p<0,05). Houve diferença significativa entre os tipos de cimentos (p<0,0001), entre as localizações (p<0,0001) e a interação cimento x localização foi significativa (p<0,0001). A configuração do pino não influenciou nos valores de resistência adesiva. Os cimentos LU e UN apresentaram os maiores valores de adesão em toda extensão da dentina radicular. Os cimentos ARC e CP apresentaram valores de adesão no terço cervical semelhantes, contudo, a resistência adesiva decresceu no sentido coroa-ápice para o ARC. O cimento MAX apresentou os menores valores de adesão. / Mestre em Odontologia
Read more

Page generated in 0.0507 seconds