• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 9
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise biomecânica de dentes restaurados com retentor intra-radicular fundido, com e sem férula / Biomechanics analysis of restored teeth with cast intra-radicular retainer, with and without ferrule

Poiate, Isis Andrea Venturini Pola 11 December 2007 (has links)
O objetivo foi avaliar a influência de variações no formato da férula dada por núcleo estojado sobre as tensões desenvolvidas na raiz em um modelo tridimensional de um segundo pré-molar superior submetido a quatro condições de carregamentos: cunha, alavanca vestibular, alavanca proximal e torção. Seis modelos foram confeccionados a partir das dimensões médias obtidas na literatura. Um deles representou o dente hígido, e outros cinco dentes restaurados com coroa e retentor intra-radicular fundido: um simulou núcleo simples, sem férula (E2A0), e em quatro modelos variou-se o tamanho do espelho (E) em 1/3 da espessura da parede radicular (E1) ou 2/3 (E2) e a altura (A) da férula foi equivalente a E1 (A1) ou a E2 (A2); ou seja: os modelos E1A1 e E2A2 tiveram 45º de inclinação do bisel da férula. Todas as estruturas foram consideradas homogêneas, isotrópicas e lineares elásticas. Os resultados permitem afirmar que a férula não parece necessária para melhorar a distribuição de tensões e que, exceto para o caso de carregamento longitudinal (que demonstrou ser o menos danoso), o cimento ficou submetido a tensões que justificam sua fratura e a dentina apresentou tensões de tração compatíveis com fraturas longitudinais (com início na crista óssea), especialmente para a alavanca vestibular. / The aim was to evaluate the influence of variations in the radicular ferrule format given by the casing core on stress developed in the root in a three-dimensional model of one upper second premolar submitted to four load conditions: wedge, vestibular lever, proximal lever and torsion. Six models were built according the average dimensions obtained from the literature. One of them represented the sound tooth, and other five restored teeth with cast radicular retainer and crown: one simulated simple core, without ferrule (E2A0), and in four models the mirror (E) size was varied in 1/3 of the radicular wall thickness (E1) or 2/3 (E2) and the ferrule height (A) was equivalent to E1 (A1) or E2 (A2); or be: E1A1 and E2A2 had 45º inclination of the ferrule bisel. All the structures were considered homogeneous, isotropic and linear elastic behavior. The results allow to affirm that the ferrule doesn\'t seem necessary to improve the stress distribution and that, except for the longitudinal load case (that demonstrated to be the least harmful), the cement was submitted to stress that justify his fracture and the dentine presented compatible tensile stress with longitudinal fractures (with beginning in the bone crest), especially for the vestibular lever.
2

Influência de dois tipos de retentores intra-radiculares e do tipo de coroa total na resistência e modo de fratura de raízes de incisivos superiores

Zamboni, Sandra Regina Oliveira Costa [UNESP] 22 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-22Bitstream added on 2014-06-13T20:45:50Z : No. of bitstreams: 1 zamboni_sroc_dr_sjc.pdf: 562964 bytes, checksum: 96289338fffdaef0884f0ad0364b5145 (MD5) / O objetivo neste estudo foi avaliar e comparar a resistência à fratura de incisivos centrais restaurados usando dois tipos de pinos intra-radiculares: núcleo metálico fundido e pinos de fibra de quartzo, reconstruídos com diferentes tipos de coroas. A hipótese nula testada foi que a resistência a fratura desses corpos de prova não apresentariam diferença quanto ao tipo de pino e tipo de coroa. Sessenta incisivos centrais superiores foram divididos em 6 grupos: G1- núcleo metálico fundido + coroa em cerômero, G2- núcleo metálico fundido + coroa metalo-cerâmica, G3- núcleo metálico fundido + coroa em e-max, G4 – pino de fibra de quartzo e pinos acessórios + coroa em cerômero, G5- pino de fibra de quartzo e pinos acessórios + coroa metalo-cerâmica e G6- pino de fibra de quartzo e pinos acessórios + coroa em e-max. Todos os espécimes foram submetidos à ciclagem mecânica com freqüência de 2 Hz e 500.000 ciclos com carga de 3Kg. Os corpos de prova foram submetidos a teste de compressão em uma máquina universal de ensaios (Emic) com velocidade de carga de 1,0 mm/min até a sua fratura. Os valores de resistência à fratura foram G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. A análise de variância (ANOVA) (p<0,05) mostrou diferença estatisticamente significante para os pinos. Quanto à análise de fratura, os núcleos metálicos fundidos apresentaram o maior número de amostras com fratura desfavoráveis quando comparados os pinos de fibra de quartzo. O conjunto pino de fibra restaurados com coroa metalo cerâmica, apresentou valor de resistência à fratura estatisticamente maior quando comparado aos demais grupos segundo o teste de Tukey (5%), Metalo cerâmica - 64,12±13,69 kgf, difere estatisticamente das demais coroas metal free - 52,59±9,88 kgf e cerômero - 51,20±10,08 kgf que... / The aim of this study was to compare the fracture resistance and failure of maxillary incisors restored using fiber post and metallic post under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of fiber post, metallic post and typo of full coverage crown. Sixty maxillary incisors were divided into 6 groups of 10 each. G1- metallic post + metallic ceramic crowns, G2- metallic post + e-max system, G3- metallic post + cerômeros, G4- Fiber post and accessories post + metallic ceramic crowns, G5- Fiber post and accessories post + e-max system and G6- Fiber post and accessories post + cerômeros. The specimens were submitted a mechanical loading at a frequency of 2 Hz for a total of 500.000 cycles. After were taken to the Universal Test Machine for the fracture resistance at 1,0 mm/min speed. The fracture resistance values were G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. Results show statistically significant differences in relation to the type of the posts (ANOVA) (p<0,05). Fracture analyses about metallic post showed the most unfavorable fracture and fiber post restored with metallic crown showed statistically significant difference in relation to the others groups. Tukey test (5%) showed Metallic-crown - 64,12±13,69 kgf, is statistically difference than the other crowns metal free - 52,59±9,88 kgf and Sinfony crowns - 51,20±10,08 kgf that was not different between itself. The result of this study indicate that the use of fiber posts increase their resistance to fracture and improve the prognosis in case of fracture
3

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro

Lima, Luiz Rafael Calixto [UNESP] 03 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-03Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 lima_lrc_me_arafo.pdf: 301269 bytes, checksum: e249a410590b65d0ca0f202c5160930d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... / The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey’s test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs.
4

Análise biomecânica de dentes restaurados com retentor intra-radicular fundido, com e sem férula / Biomechanics analysis of restored teeth with cast intra-radicular retainer, with and without ferrule

Isis Andrea Venturini Pola Poiate 11 December 2007 (has links)
O objetivo foi avaliar a influência de variações no formato da férula dada por núcleo estojado sobre as tensões desenvolvidas na raiz em um modelo tridimensional de um segundo pré-molar superior submetido a quatro condições de carregamentos: cunha, alavanca vestibular, alavanca proximal e torção. Seis modelos foram confeccionados a partir das dimensões médias obtidas na literatura. Um deles representou o dente hígido, e outros cinco dentes restaurados com coroa e retentor intra-radicular fundido: um simulou núcleo simples, sem férula (E2A0), e em quatro modelos variou-se o tamanho do espelho (E) em 1/3 da espessura da parede radicular (E1) ou 2/3 (E2) e a altura (A) da férula foi equivalente a E1 (A1) ou a E2 (A2); ou seja: os modelos E1A1 e E2A2 tiveram 45º de inclinação do bisel da férula. Todas as estruturas foram consideradas homogêneas, isotrópicas e lineares elásticas. Os resultados permitem afirmar que a férula não parece necessária para melhorar a distribuição de tensões e que, exceto para o caso de carregamento longitudinal (que demonstrou ser o menos danoso), o cimento ficou submetido a tensões que justificam sua fratura e a dentina apresentou tensões de tração compatíveis com fraturas longitudinais (com início na crista óssea), especialmente para a alavanca vestibular. / The aim was to evaluate the influence of variations in the radicular ferrule format given by the casing core on stress developed in the root in a three-dimensional model of one upper second premolar submitted to four load conditions: wedge, vestibular lever, proximal lever and torsion. Six models were built according the average dimensions obtained from the literature. One of them represented the sound tooth, and other five restored teeth with cast radicular retainer and crown: one simulated simple core, without ferrule (E2A0), and in four models the mirror (E) size was varied in 1/3 of the radicular wall thickness (E1) or 2/3 (E2) and the ferrule height (A) was equivalent to E1 (A1) or E2 (A2); or be: E1A1 and E2A2 had 45º inclination of the ferrule bisel. All the structures were considered homogeneous, isotropic and linear elastic behavior. The results allow to affirm that the ferrule doesn\'t seem necessary to improve the stress distribution and that, except for the longitudinal load case (that demonstrated to be the least harmful), the cement was submitted to stress that justify his fracture and the dentine presented compatible tensile stress with longitudinal fractures (with beginning in the bone crest), especially for the vestibular lever.
5

Avaliação de núcleo metálico fundido, núcleo com fibra de vidro e endocrown em cerâmica: análise comparativa pelo método dos elementos finitos

Rossato, Desirée Mory [UNESP] 23 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-23Bitstream added on 2014-06-13T19:20:24Z : No. of bitstreams: 1 rossato_dm_dr_arafo.pdf: 3020954 bytes, checksum: 1a5b7cd1dca8b24d2c32a870ea1c52b3 (MD5) / Dentes tratados endodonticamente têm uma maior incidência a fraturas, tornando sua restauração um desafio para a Odontologia. Foram selecionados três incisivos centrais superiores humanos os quais foram restaurados com núcleo metálico fundido e coroa de cerâmica IPS emax®Press, núcleo de preenchimento em resina ccomposta associado ao pino de fibra de vidro e coroa de cerâmica IPS emax®Press e endocrown em cerâmica IPS emax®Press. Os dentes foram levados ao teste estático de fratura. Paralelamente foi realizado um modelo virtual de um incisivo central que apresentava características e restaurações representativas dos dentes que foram levados ao teste de fratura. A análise computacional pelo método dos elementos finitos 3D foi realizada. Os resultados obtidos nos dois tipos de análise realizada mostram que a coroa endocrown e o pino de fibra de vidro apresentaram um padrão de fratura que não afetou a estrutura radicular enquanto que o núcleo metálico fundido apresentou um padrão de fratura desfavorável envolvendo a estrutura radicular condenando o dente. Na análise dos elementos finitos obtivemos uma correta previsibilidade de onde as coroas e núcleos poderiam falhar. A análise dos elementos finitos é uma metodologia importante na análise de novas técnicas e novos materiais. / Restoration of endodontically treated teeth is a common problem in restorative dentistry, related to the fractures occurring in such teeth. Three human maxillary central incisor were selected and restaured with metal core and IPS emax®ceramic crown, glass fiber post with composite core and IPS emax®ceramic crown and IPS emax®ceramic endocrown. Static loading test were performed on each specimen until failure. Paralleled a 3D model of a maxillary central incisor is presented. The same characteristics of the real teeth used in the mechanical test were applied. A 3D finite elements analysis was made. The results of both analysis shows that endocrown and fiber post have a pattern of fracture that not involve the root while metal core presents a catastrophic pattern of fracture in the root. The FEM analysis is an important methodology in the development of new materials.
6

Avaliação de núcleo metálico fundido, núcleo com fibra de vidro e endocrown em cerâmica : análise comparativa pelo método dos elementos finitos /

Rossato, Desirée Mory. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Pedro Yoshito Noritomi / Banca: Luiz Alberto Plácido Penna / Banca: Edson Alves de Campos / Banca: Celso Luiz de Angelis Porto / Resumo: Dentes tratados endodonticamente têm uma maior incidência a fraturas, tornando sua restauração um desafio para a Odontologia. Foram selecionados três incisivos centrais superiores humanos os quais foram restaurados com núcleo metálico fundido e coroa de cerâmica IPS emax®Press, núcleo de preenchimento em resina ccomposta associado ao pino de fibra de vidro e coroa de cerâmica IPS emax®Press e endocrown em cerâmica IPS emax®Press. Os dentes foram levados ao teste estático de fratura. Paralelamente foi realizado um modelo virtual de um incisivo central que apresentava características e restaurações representativas dos dentes que foram levados ao teste de fratura. A análise computacional pelo método dos elementos finitos 3D foi realizada. Os resultados obtidos nos dois tipos de análise realizada mostram que a coroa endocrown e o pino de fibra de vidro apresentaram um padrão de fratura que não afetou a estrutura radicular enquanto que o núcleo metálico fundido apresentou um padrão de fratura desfavorável envolvendo a estrutura radicular condenando o dente. Na análise dos elementos finitos obtivemos uma correta previsibilidade de onde as coroas e núcleos poderiam falhar. A análise dos elementos finitos é uma metodologia importante na análise de novas técnicas e novos materiais. / Abstract: Restoration of endodontically treated teeth is a common problem in restorative dentistry, related to the fractures occurring in such teeth. Three human maxillary central incisor were selected and restaured with metal core and IPS emax®ceramic crown, glass fiber post with composite core and IPS emax®ceramic crown and IPS emax®ceramic endocrown. Static loading test were performed on each specimen until failure. Paralleled a 3D model of a maxillary central incisor is presented. The same characteristics of the real teeth used in the mechanical test were applied. A 3D finite elements analysis was made. The results of both analysis shows that endocrown and fiber post have a pattern of fracture that not involve the root while metal core presents a catastrophic pattern of fracture in the root. The FEM analysis is an important methodology in the development of new materials. / Doutor
7

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

Cardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
8

Estudo in vitro da adaptação de retentores intra-radiculares fundidos, modelados com diferentes resinas acrílicas autopolimerizáveis / In vitro study of the fit of cast post and core, obtained from different acrylic resin patterns

Rennó, Denise Galhardo 21 September 2005 (has links)
Dentes tratados endodonticamente se encontram freqüentemente mutilados por cárie ou pelo próprio acesso ao canal. A estrutura dental remanescente necessita de tratamento especial para prevenir futuras fraturas. Quando uma grande parte da coroa dental foi perdida, é comum não haver retenção para a restauração na dentina remanescente. Nestas situações, uma restauração com retenção intracanal se faz necessária. Apenas a porção radicular pode oferecer a retenção apropriada para a instalação de uma coroa artificial estética e funcional. Diferentes técnicas podem ser usadas para a fabricação do retentor intra-radicular fundido. Neste estudo, foi escolhida a técnica direta para a confecção dos padrões de fundição em resina acrílica autopolimerizável. Usamos seis padrões metálicos com dimensões que simulavam dentes anteriores preparados para receber um retentor intra-radicular. Os condutos foram preenchidos com resina acrílica, usando um pincel bem fino, e pinos plásticos foram inseridos no interior dos canais. Após a polimerização do pino, adicionamos novas porções de resina acrílica para confecção das partes correspondentes aos núcleos. Essa técnica permite a correção de eventuais falhas, caso haja necessidade. Os padrões de fundição foram então incluídos em material de revestimento e fundidos em liga de níquel-cromo. O retentor intra-radicular fundido foi removido do revestimento e limpo. Apenas removemos os nódulos da superfície do metal, a qual recebeu, posteriormente, jateamento com óxido de alumínio. O objetivo deste estudo foi comparar a adaptação marginal de 54 retentores intra-radiculares fundidos, modelados com três resinas acrílicas autopolimerizáveis diferentes: 18 em DuraLay (Reliance Dental MFG Co., USA); 18 em Pattern Resin (GC Products, Japan); 18 em Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). Os retentores intra-radiculares fundidos foram assentados sobre os seis padrões metálicos. As fendas marginais foram observadas em microscópio eletrônico de varredura (MEV). As medições foram registradas e submetidas à análise estatística. Os resultados obtidos mostraram que: (1) Os retentores intra-radiculares fundidos obtidos de padrões de fundição modelados com a resina DuraLay mostraram-se significativamente melhor adaptados (42,31 µm ± 9,54 µm) quando comparados aos retentores intra-radiculares fundidos obtidos de padrões das resinas Pattern Resin (73,25 µm ± 32,86 µm) e Cop Clas (95,32 µm ± 45,02 µm) respectivamente; (2) Não houve diferença estatisticamente significante (p=0,273) na diferença média das fendas marginais dos retentores intra-radiculares fundidos modelados com a resina Pattern Resin e modelados com a resina Cop Clas (22,07 µm ± 13,13 µm). / Endodontically treated teeth are often mutilated by caries and access requirements. The remaining structure requires special treatment to prevent further destruction. When a large portion of the clinical crown has been lost, it is often impossible to achieve sufficient anchorage of a restoration in the remaining dentin. In such situations, a root-canal-retained restoration is required. Only the root portion can offer the needed retention for a functional and esthetic artificial crown. Different approaches can be taken to the fabrication of cast posts and cores. In this study, direct method was chosen to fashion it, by auto polymerizing acrylic resin. We used six standard metal patterns that simulate an anterior tooth prepared to receive cast post and core. Burn-out plastic patterns were fitted into the root canal and, using a fine sable hair brush, the polymer was introduced to fill the canal. After polymerization of the post, additional auto -polymerizing acrylic resin was added to form the core portion. This process can be repeated and correct if necessary. The acrylic resin patterns were then invested and casting was performed using nickel-chromium alloy. The cast was removed from investment. Cleaning was performed exclusively to remove the small positive nodules on the metal post and sandblast surface. The aim of this research was to compare the marginal fit of 54 cast posts constructed with three auto -polymerizing acrylic resins: 18 of DuraLay (Reliance Dental MFG Co., USA); 18 of Pattern Resin (GC Products, Japan); 18 of Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). The posts and cores were seated over the six standard metal patterns. Marginal discrepancies were bserved in scanning electron microscope (SEM). The measurements were registered and statistically analyzed. The results obtained showed that: (1) The cast post and core obtainedfrom DuraLay (42,31 µm ± 9,54 µm) had significant best fit than the cast post and core obtained from the others acrylic resins, Pattern Resin (73,25 µm ± 32,86 µm) and Cop Clas (95,32 µm ± 45,02 µm) respectively; (2) No significant statistic difference occur p=0,273) in the average marginal gap between the cast posts and cores obtained from Pattern Resin and Cop Class (22,07 µm ± 13,13 µm).
9

Influência do modo de aplicação e viscosidade do ácido fosfórico 37% na adesão de pinos de fibra de vidro em condutos radiculares

Scholz, Maria Fernanda Costa 23 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-31T17:05:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) / Made available in DSpace on 2018-07-31T17:05:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) Previous issue date: 2018-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar a influência da viscosidade do ácido fosfórico e do modo de aplicação nos valores de resistência de união de pino de fibra de vidro cimentados na dentina radicular através do teste de pushout. Raízes de 32 pré-molares foram preparadas endodonticamente e divididas em 4 grupos (n = 8) de acordo com a combinação dos seguintes fatores: viscosidade do ácido e forma de aplicação. Após aplicação do adesivo Universal no interior dos condutos, foram realizadas as cimentações dos pinos com o cimento resinoso RelyX ARC. Em seguida, as raízes foram seccionadas transversalmente em 6 fatias de aproximadamente 1 mm e o teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os resultados de resistência de união foram submetidos a uma análise de variância de três fatores de medidas repetidas e teste de Tukey (alpha = 0.05). A interação dupla modo de aplicação vs. viscosidade do ácido (p = 0,0002) e o terço radicular (p < 0,0001) foram estatisticamente significantes. O maior valor de resistência de união foi observado no grupo condicionado com ácido fosfórico líquido sob o modo de aplicação sônica (p < 0,05) sendo todos os outros grupos semelhantes entre si. Quanto ao terço radicular, observou-se maior valor de resistência de união no terço cervical, seguido do terço médio e do terço apical terço apical (p < 0,05). Pelos resultados pode-se concluir que uma melhor adesão de pinos de fibra de vidro ao conduto radicular pode ser obtida através do condicionamento com ácido fosfórico líquido com aplicação sônica. / The aim of the present study was to evaluate the influence of the etchant viscosity (liquid or gel) and the application mode (passive or sonic) on the pushout bond strength values of fiberglass post to root dentin and the conditioning pattern on the smear-layer covered root dentin before cementation. The roots of premolars were prepared endodontically and divided into 4 groups (n = 8) according to the combination of the main factors: phosphoric acid viscosity (liquid gel) and application mode (passive or sonic). After the application of the universal adhesive into the root canals, the fiberglass posts were cemented with cementation system RelyX ARC. Then, the roots were sectioned transversely 6 slices of approximately 1 mm and the push-out test performed at a speed 0.5 mm/min. The results were submitted to a repeated measures three-way ANOVA and Tukey’s test (alpha = 0.05). The cross-product interaction mode of application vs. etchant viscosity (p = 0.0002) and the main factor root third (p < 0.0001) were statistically significant. The highest bond strength value was observed when the conditioning of the root canal was performed with a liquid phosphoric acid under sonic application mode (p < 0.05), being all other groups similar one another (p < 0.05). Regarding the root third, the highest push-out bond strength value was observed in the cervical third, followed by the medium third and the apical thirds (p < 0,05). The most common fracture pattern was the mixed failure. By the partial results one may conclude that a better bonding of fiberglass posts to root canals can be achieved when the conduits are conditioned with a
10

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

José Edgar Valdivia Cardenas 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.

Page generated in 0.1081 seconds