• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception et validation d'une matrice 2D de détecteurs à fibres scintillantes plastiques pour la dosimétrie en radiothérapie externe

Guillot, Mathieu 19 April 2018 (has links)
Cette thèse porte sur le développement et la caractérisation d’une matrice 2D de détecteurs à fibres scintillantes plastiques pour la dosimétrie des faisceaux de photons d’énergie mégavoltage utilisés en radiothérapie. Les propriétés visées lors de la conception du détecteur matriciel furent la justesse, l’équivalence à l’eau, une bonne résolution spatiale, un nombre élevé de détecteurs, et une lecture à haute fréquence des doses déposées. La première partie de cette thèse fut consacrée à améliorer la justesse de la méthode spectrale utilisée pour corriger l’effet Cerenkov. Deux procédures aptes à extraire de façon juste les coefficients d’étalonnage ont été développées. Les résultats ont montré que cette méthode peut corriger l’effet Cerenkov avec une justesse de 1%. La seconde partie de cette thèse fut consacrée à la conception, la réalisation et la validation d’un détecteur matriciel composé de 781 dosimètres insérés dans un fantôme eau-équivalent. Un système optique a aussi été développé. Il fut déterminé qu’en moyenne, l’écart-type des mesures est inférieure à 1 % pour les doses supérieures à 6.3 cGy. Il fut aussi démontré que les distributions de dose ne sont pas perturbées (à +/- 1.1 %) par la présence des dosimètres à l’intérieur du fantôme. La caractérisation de la dépendance angulaire a révélée que les incidences des faisceaux ont peu d’impact sur la justesse des mesures. Le détecteur matriciel a aussi été validé dans le contexte de la radiothérapie à intensité modulée (IMRT). Onze plans de traitement ont été mesurés et les résultats ont montré d’excellents accords avec les doses calculées à l’aide d’algorithmes convolution-superposition ou mesurées avec des films radiochromiques. La sensibilité et la spécificité du détecteur matriciel aux erreurs de position d’une lame et d’un banc de lame d’un collimateur multi-lames (MLC) ont été déterminées en appliquant la théorie de détection du signal. Cette étude conclut que les dosimètres à fibres scintillantes plastiques pourraient permettre d’améliorer la qualité de la dosimétrie en IMRT, en raison de leurs avantages par rapport aux autres dosimètres, tels que l’équivalence à l’eau, une haute résolution spatiale, la lecture à haute fréquence, et une très faible dépendance angulaire. / This thesis deals with the development and characterization of a 2D array of plastic scintillation detectors for the dosimetry of megavoltage energy photon beams used in radiation therapy. The characteristics sought with the detector array are accuracy, water-equivalence, a good spatial resolution, a large number of detectors and a high frequency readout of the doses deposited. The first part of this thesis is devoted to the improvement of the accuracy of the spectral method used to correct the Cerenkov effect. A study has determined the optimal attenuation characteristics for the optical fibers and two procedures able to accurately extract the calibration coefficients were developed. Measurements performed in various situations showed that this method can correct the Cerenkov effect with an accuracy of 1 %. The second part of this thesis relates to the design, realization and validation of a detector array consisting of 781 plastic scintillation detectors inserted vertically into a plane of a water-equivalent phantom. An novel optical system was also designed. It was determined that, on average, the standard deviation of measurements is smaller than 1 % for doses deposited greater than 6.3 cGy. It was also demonstrated that the dose distributions are not perturbed (within +/- 1.1 %) by the presence of the detectors inside the phantom. The characterization of the angular dependence showed that the incidences of radiation beams have very little effect on the accuracy of measurements. The detector array was also validated in the context of intensity-modulated radiation therapy (IMRT). Eleven treatment plans were measured and the results showed excellent agreements with dose distributions calculated with convolution-superposition algorithms or measured with radiochromic films. The sensitivity and specificity of the detector array to position errors of one leaf and one leaf bank of a multileaf collimator (MLC) were also determined by applying the principles of signal detection theory. The study concluded that plastic scintillation detectors could allow improving the quality of dosimetry in IMRT, due to their advantages compared to other dosimeters, such as water-equivalence, high frequency readout, high spatial resolution and a very low angular dependence.
2

Étude d'un système de transmission sur fibre optique plastique à saut d'indice

Thon-Adjalin, Carolle 18 April 2018 (has links)
La demande croissante pour des débits plus élevés a atteint la limite des solutions câblées actuelles. Dans ce contexte, la fibre optique plastique à saut d'indice (SI-FOP), avec son gros diamètre de câble (3 à 4 mm) et sa grande ouverture numérique semble être un candidat idéal pour la transmission du gigabit Ethernet à faible coût. Les avantages de la SI-FOP sont sa simplicité d'utilisation, sa connexion facile, l'installation à la portée de tous et sa longueur d'onde d'utilisation. Dans ce mémoire, nous déterminons un modèle mathématique réaliste de la SI-FOP dans un système à modulation d'intensité et détection directe (IM/DD) utilisant la modulation Discrete Multi Tone (DMT). Les caractéristiques du canal sont évaluées en déterminant la capacité théorique au sens de Shannon et la capacité pratique DMT avec les algorithmes d'allocation de bits (« rate adaptive bit loading ») comme le water-filling, les algorithmes de Chow et de Levin-Campello. Mots clés : fibre optique plastique, saut d'indice, modulation d'intensité, détection directe, modulation DMT, couplage de modes, « power flow equation », problèmes d'optimisation sous-contraintes, « rate adaptive water-filling », algorithme de Chow, algorithme de Levin-Campello, capacité théorique au sens de Shannon, capacité pratique DMT.

Page generated in 0.1198 seconds