• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • 2
  • Tagged with
  • 10
  • 10
  • 7
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analyse et optimisation des performances de la technique VMAT pour son utilisation en radiothérapie / Analysis and optimisation of performance of the VMAT technique for its use in radiotherapy

Lafond, Caroline 15 November 2013 (has links)
La technique de radiothérapie VMAT (Volumetric Modulated Arc Therapy), diffusée en 2009, combine les avantages des techniques d'arc thérapie dynamique aux avantages des techniques de radiothérapie conformationnelle avec modulation d'intensité (RCMI) par faisceaux stationnaires. L'objectif de la thèse est de rendre optimales les conditions de mise en œuvre du VMAT autour d'un accélérateur linéaire d'électrons Synergy/Elekta afin de sécuriser la technique et de pouvoir bénéficier de l'apport clinique potentiellement attendu. Sur la base d'une analyse de l'influence des différents paramètres de la chaîne de traitement, nous proposons des éléments d'optimisation du traitement à la fois sur la planification dosimétrique et sur le contrôle de son exécution sur la machine. Nous montrons que si la qualité de l'optimisation de la technique dépend des caractéristiques intrinsèques de l'accélérateur, elle est également fortement influencée par le paramétrage du système de planification des traitements (TPS). Nous mettons en évidence des différences comparées des collimateurs Beam Modulateur (largeur de lames de 4 mm) et MLCi2 (largeur de lames de 10 mm) tant sur le plan de la distribution de dose obtenue que sur l'efficience. Nous montrons que, si pour deux principaux TPS commercialisés (Pinnacle/Philips et Monaco/Elekta) les distributions de dose aux volumes cibles sont peu modifiées, les différences de méthodes implémentées influencent la distribution de dose aux tissus sains. Nous proposons des programmes de contrôles de qualité au niveau de l'accélérateur, des plans dosimétriques de traitement et de l'exécution des traitements. Afin de garantir un niveau de confiance élevé sur la dose délivrée, nous proposons une méthode d'évaluation de la fluence délivrée en cours de traitement basée sur l'analyse des paramètres machines. Nous établissons que le processus de traitement VMAT optimisé fournit des performances de qualité supérieure que les techniques de RCMI par faisceaux stationnaires pour quatre localisations tumorales majeures étudiées. / VMAT (Volumetric Modulated Arc Therapy) technique has been introduced in 2009, it combines advantage of arctherapy techniques with advantage of IMRT (Intensity Modulated Radio Therapy) techniques delivered with stationary beams. The purpose of the thesis is to optimise implementation conditions of VMAT for a Synergy/Elekta linear accelerator in order to secure the technique and to be able to benefit from potentially expected clinical improvement. From analysis of influence of various work flow parameters, we propose treatment optimisation factors both on dosimetric planning and on delivering control on the accelerator. We show that if optimisation quality depends on intrinsic accelerator characteristics, it also depends very much on configuration of treatment planning system (TPS). We highlight compared differences between Beam Modulateur (leaf width of 4 mm) and MLCi2 (leaf width of 10 mm) on dose distribution and on efficiency. We show that if differences of dose distributions are small for two major TPS (Pinnacle/Philips and Monao/Elekta), the differences of implemented methods affect dose distribution of healthy tissues. We suggest quality control set for accelerators, for treatment plans and for treatment delivery. In order to provide a high safety level on delivered dose, we suggest an evaluation method of the real fluence provided during treatment delivery by analysing accelerator parameters. We establish that optimised process of VMAT treatment provides better performance than RCMI techniques delivered with stationary beams for the four major cancer cases that has been studied.
2

Advanced modulation for optical communication systems

Yekani Khoei, Aminreza 21 February 2019 (has links)
La demande toujours croissante pour la capacité du réseau conduit au développement de systèmes de communication optique pour couvrir les normes Terabit Ethernet récemment proposées. Les applications de courte distance nécessitent une solution peu coûteuse et peu complexe avec détection directe. Cependant, le coût de la détection cohérente diminue chaque jour et en fait un bon candidat pour les applications à courte distance futures afin d'accroître l'efficacité spectrale et d'utiliser des formats de modulation avancés. Dans cette thèse, nous étudions des solutions pour les applications court-courrier actuelles et futures. Dans la première partie, nous nous concentrons sur des solutions pour les applications de courte distance. Le premier chapitre est la première démonstration de la transmission multi-tonalité discrète (DMT) à plus de 100 Gb/s en utilisant une photonique au silicium en bande O (SiP). Nous comparons expérimentalement le DMT avec la modulation d'amplitude d'impulsion (PAM) sur la bande O. Notre expérience montre qu'en augmentant la longueur des fibres de plus de 10 km, la PAM surpasse le DMT. Pour la bande C, nous utilisons un multi-ton discret à bande latérale unique (SSB-DMT) pour éviter l'effet d'évanouissement de la puissance induit par la dispersion chromatique. Nous étudions l'effet du bruit de phase, de la dispersion chromatique et de la sensibilité du récepteur pour optimiser le signal du DMT et extraire des équations théoriques pour calculer le taux d'erreur binaire (BER) du SSB-DMT. Ensuite, nous comparons la PAM sur bande O avec le SSB-DMT sur bande C et quantifions l'impact des limitations imposées par le matériel sur les deux formats de modulation. Notre étude fournit un outil analytique pour les applications de courte distance afin de sélectionner le format et le matériel de modulation appropriés en fonction de la portée requise, du débit binaire, etc. Dans la deuxième partie, le ciblage des futurs systèmes de détection cohérents justifié l'utilisation d'un format de modulation complexe avec détection cohérente. Nous utilisons un format de modulation avancé dans lequel nous avons combiné la propagation de transformée de Fourier discrète avec le DMT pour augmenter l'efficacité spectrale. Le format de modulation hybride a un rapport de puissance crête à moyenne inférieur (vis-à-vis du DMT) et une efficacité spectrale plus élevée (vis-à-vis de la QAM _a porteuse unique). Dans la première étape, nous comparons expérimentalement les performances des modulations hybrides, DMT standard et monoporteuse en utilisant un modulateur SiP IQ. Ensuite, nous développons une stratégie de contrôle pour le format de modulation hybride en échangeant la non-linéarité de la fonction de transfert du modulateur et le rapport signal / bruit optique. Le format de modulation hybride est ensuite optimisé pour avoir un débit maximum. En utilisant une simulation de Monte Carlo, nous comparons le format de modulation hybride optimisé avec le DMT standard pour différents débits binaires. Enfin, nous avons une comparaison de complexité entre hybride et DMT pour différentes longueurs de fibre. / Ever increasing demand for network capacity is driving the development of optical communication systems to cover recently proposed Terabit Ethernet standards. Short haul applications need low cost and low complexity solutions with direct detection, as the cost of coherent detection comes down, it will become a good candidate for future short-haul applications to increase spectral efficiency and exploit advanced modulation formats. In this thesis, we investigate solutions for both current and future short-haul systems. In the first part, we focus on solutions for short haul applications. The first chapter is the first time demonstration of more than 100 Gb/s discrete multi-tone (DMT) transmission using an O-band silicon photonics (SiP). We experimentally compare DMT with pulse amplitude modulation (PAM) on O-band. Our experiment shows that by increasing fiber length more than 10 km, PAM outperforms DMT. For C-band, we use single sideband discrete multi-tone (SSB-DMT) to avoid chromatic dispersion-induced power fading e_ect. We study the effect of phase noise, chromatic dispersion, and receiver sensitivity to optimize DMT signal and extract theoretical equations to calculate bit error rate (BER) of SSB-DMT. Next, we analytically compare PAM on O-band with SSB-DMT on C-band and quantify the impact of hardware-imposed limitations on both modulation formats. Our study provides an analytical tool for short haul applications to select appropriate modulation format and hardware based on required reach, bit rate, etc. In the second part we examine complex modulation formats that will be enabled in the future by low cost, integrated components for coherent detection.. We use an advanced modulation format in which we combined discrete Fourier transform spread with DMT to increase spectral efficiency. Hybrid modulation format has a lower peak to average power ratio (vis-a-vis DMT) and higher spectral efficiency (vis-a-vis single carrier QAM). In the first step, we experimentally compare the performance of the hybrid, standard DMT, and single carrier modulations using a SiP IQ modulator. Next, we develop a driving strategy for hybrid modulation format by trading off the modulator transfer function non-linearity and optical signal to noise ratio. Then hybrid modulation format is optimized to have maximum throughput. Using Monte Carlo simulation we compare optimized hybrid modulation format with standard DMT for different bit rates. Finally, we have a complexity comparison between hybrid and DMT for different fiber lengths to motivate same investigation for long-haul applications where, we should consider fiber non-linearity, attenuation, a polarization multiplexing.
3

Analyse et optimisation des performances de la technique VMAT pour son utilisation en radiothérapie

Lafond, Caroline 18 November 2013 (has links) (PDF)
La technique de radiothérapie VMAT (Volumetric Modulated Arc Therapy), diffusée en 2009, combine les avantages des techniques d'arc thérapie dynamique aux avantages des techniques de radiothérapie conformationnelle avec modulation d'intensité (RCMI) par faisceaux stationnaires. L'objectif de la thèse est de rendre optimales les conditions de mise en œuvre du VMAT autour d'un accélérateur linéaire d'électrons Synergy/Elekta afin de sécuriser la technique et de pouvoir bénéficier de l'apport clinique potentiellement attendu. Sur la base d'une analyse de l'influence des différents paramètres de la chaîne de traitement, nous proposons des éléments d'optimisation du traitement à la fois sur la planification dosimétrique et sur le contrôle de son exécution sur la machine. Nous montrons que si la qualité de l'optimisation de la technique dépend des caractéristiques intrinsèques de l'accélérateur, elle est également fortement influencée par le paramétrage du système de planification des traitements (TPS). Nous mettons en évidence des différences comparées des collimateurs Beam Modulateur (largeur de lames de 4 mm) et MLCi2 (largeur de lames de 10 mm) tant sur le plan de la distribution de dose obtenue que sur l'efficience. Nous montrons que, si pour deux principaux TPS commercialisés (Pinnacle/Philips et Monaco/Elekta) les distributions de dose aux volumes cibles sont peu modifiées, les différences de méthodes implémentées influencent la distribution de dose aux tissus sains. Nous proposons des programmes de contrôles de qualité au niveau de l'accélérateur, des plans dosimétriques de traitement et de l'exécution des traitements. Afin de garantir un niveau de confiance élevé sur la dose délivrée, nous proposons une méthode d'évaluation de la fluence délivrée en cours de traitement basée sur l'analyse des paramètres machines. Nous établissons que le processus de traitement VMAT optimisé fournit des performances de qualité supérieure que les techniques de RCMI par faisceaux stationnaires pour quatre localisations tumorales majeures étudiées.
4

Analyse et optimisation des performances de la technique VMAT pour son utilisation en radiothérapie

Lafond, Caroline 15 November 2013 (has links) (PDF)
La technique de radiothérapie VMAT (Volumetric Modulated Arc Therapy), diffusée en 2009, combine les avantages des techniques d'arc thérapie dynamique aux avantages des techniques de radiothérapie conformationnelle avec modulation d'intensité (RCMI) par faisceaux stationnaires. L'objectif de la thèse est de rendre optimales les conditions de mise en œuvre du VMAT autour d'un accélérateur linéaire d'électrons Synergy/Elekta afin de sécuriser la technique et de pouvoir bénéficier de l'apport clinique potentiellement attendu. Sur la base d'une analyse de l'influence des différents paramètres de la chaîne de traitement, nous proposons des éléments d'optimisation du traitement à la fois sur la planification dosimétrique et sur le contrôle de son exécution sur la machine. Nous montrons que si la qualité de l'optimisation de la technique dépend des caractéristiques intrinsèques de l'accélérateur, elle est également fortement influencée par le paramétrage du système de planification des traitements (TPS). Nous mettons en évidence des différences comparées des collimateurs Beam Modulateur (largeur de lames de 4 mm) et MLCi2 (largeur de lames de 10 mm) tant sur le plan de la distribution de dose obtenue que sur l'efficience. Nous montrons que, si pour deux principaux TPS commercialisés (Pinnacle/Philips et Monaco/Elekta) les distributions de dose aux volumes cibles sont peu modifiées, les différences de méthodes implémentées influencent la distribution de dose aux tissus sains. Nous proposons des programmes de contrôles de qualité au niveau de l'accélérateur, des plans dosimétriques de traitement et de l'exécution des traitements. Afin de garantir un niveau de confiance élevé sur la dose délivrée, nous proposons une méthode d'évaluation de la fluence délivrée en cours de traitement basée sur l'analyse des paramètres machines. Nous établissons que le processus de traitement VMAT optimisé fournit des performances de qualité supérieure que les techniques de RCMI par faisceaux stationnaires pour quatre localisations tumorales majeures étudiées.
5

Application des innovations technologiques de la radiothérapie au traitement des cancers ORL : résultats cliniques de la radiothérapie conformationnelle avec modulation d'intensité : applications de l'imagerie embarquée en radiothérapie ORL / Radiation therapy technology innovations applied to the treatment of head and neck patients : Clinical results of Intensity Modulated Radiotherapy (IMRT) : Contribution of Image Guided Radiotherapy (IGRT) in the management of head and neck patients treated with IMRT

Graff-Cailleaud, Pierre 10 November 2011 (has links)
Dans une démarche d'évaluation rigoureuse des innovations technologiques de la radiothérapie, notre travail de thèse a été construit autours de 2 thématiques : 1) Evaluation clinique des résultats de la radiothérapie conformationnelle avec modulation d'intensité (RCMI) appliquée au traitement des cancers ORL. La première étude rapporte les conclusions d'un enregistrement prospectif monocentrique du devenir au long cours des patients ORL traités par RCMI. Le contrôle locorégional est excellent et les niveaux de toxicité faibles. Des recommandations dosimétriques (dose aux parotides) adaptées à nos pratiques ont été établies. La deuxième étude rapporte les résultats d'une comparaison nationale multicentrique de la qualité de vie des patients traités pour un cancer ORL, soit par radiothérapie conventionnelle, soit par RCMI. Le bénéfice de la RCMI est remarquable dans les domaines du confort de la sphère buccale et de la prise alimentaire orale. 2) Evaluation de l'apport de l'imagerie embarquée (Cone Beam CT ou CBCT) dans la prise en charge des patients traités par RCMI pour un cancer ORL. Un premier projet propose, sur un panel de patients ORL traités par RCMI, le contrôle qualité de la distribution de la dose réellement délivrée. Le retentissement dosimétrique des variations anatomiques est discuté. L'apport d'outils dosimétriques spécifiques est étudié. Le second projet a pour objectif de quantifier la mobilité relative des régions anatomiques qui composent la sphère ORL et d'étudier l'impact dosimétrique lié au choix de différentes procédures de recalage. Une recommandation sur les modalités d'utilisation des images CBCT a pu être proposée. / Numerous and exciting technological innovations were recently developed in radiotherapy. We aimed to assess benefits in two specific fields. 1) Clinical results of Intensity Modulated Radiotherapy (IMRT) applied to the treatment of Head and Neck (H&N) patients. The first study was a long-term monocentric prospective registration of all H&N patients treated with IMRT in our institution. Locoregional control was excellent and toxicities limited. Recurrences were in-field. Dosimetric recommendations (parotids mean dose) were established. The second study assessed the impact of IMRT on health-related quality of life for H&N patients through a multicentric matched-pair comparison with conventional radiotherapy. Outstanding benefits were observed particularly in the fields of salivary dysfunction and oral discomfort. 2) Contribution of Image Guided Radiotherapy (IGRT) in the management of H&N patients treated with IMRT. The first study was a monitoring of delivered dose, using 3D dose recalculation from Megavoltage Cone-Beam CT (CBCT), as a quality assurance measure of a panel of H&N IMRT patients aligned with IGRT. Dosimetric consequences of anatomical changes were assessed. Contribution of color-coded MVCBCT dose-difference maps was studied. The aim of the second study was to quantify the inherent relative mobility between anatomic regions of the H&N area and to assess the dosimetric impact of several different matching procedures. Recommendations for the use of CBCT images in a daily practice were established.
6

Développement d'une technique de radiothérapie stéréotaxique des cancers de la prostate reposant sur deux concepts différents de préservation de la paroi rectale / The implementation of stereotactic body radiotherapy for prostate cacner with two different approaches for sparing the rectal-wall

Udrescu, Mihaela 19 December 2013 (has links)
Le présent travail de thèse décrit le développement d'un protocole d'irradiation stéréotaxique combinée à une radiothérapie conformationnelle avec modulation d'intensité. Ce projet a été initiée dans le service de radiothérapie-oncologie du Centre Hospitalier Lyon Sud. La première partie de ce travail fait état d'une revue de littérature sur les techniques d'irradiation du cancer de la prostate. Trois grands thèmes de recherche ont été identifiés et developpés : un premier thèse de recherche portant sur la définition optimale des volumes à irradier lors d'une irradiation stéréotaxique de la prostate et la fiabilité d'uin repérage de l'oragane par des marqueurs intra-prostatiques. La deuxième thématique de recherche était dédiée à la planification du traitement stéréotaxique de la prostate avec pour principal objectif une protection optimale de la paroi rectale avec deux approches différentes : a) une augmentation focalisée de la dose d'irradiation uniquement sur la tumeur macroscopiquement visible, ou b) l'utilisation d'un gel injecté entre la paroi du rectum et la prostate. Le nombre optimal de faisceaux à utiliser ainsi que l'énergie la mieux adaptée ont été évalués dans le cadre de la première approche avec uin boost intégré.. La trosième thématique portait sur les contrôles qualité à réaliser dans le cadre de la mise en route de cette technique d'irradiation. Trois détecteur dédiés aux contrôles de la distribution de dose sous l'accélarateur ont été évalués. L'ensemble de ces travaux serviront de supports à la réalisation d'une étude de phase II intégrant une irradiation stéréotaxique des cancers de la prostate avec injection de gel d'acide hyaluronique entre le rectum et la prostate / The current work decribes the implementation of a protocol for stereotactic body radiotherapy (SBRT) combined with an intensity-modulated radiation therapy technique (IMRT). the project was initiated in the Department of Radiation-Oncology from Lyon Sud Hospital. The first part summarizes the state of the art of prostate cancer with a literature review on irradiation techniques. Three research themes were described and developped : The first theme discusses the optimal definition of the volumes to be irradiated during a prostate SBRT and the accuracy of the target localization using intraprostatic markers. The second theme of research describes the treatment planning for prostate SBRT having as main purpose an optimal protection of the rectal-wall with two different approaches: a) an augmentation of the dose with simultaneous integrated boost only into visible macroscopic tumor, or b) the use of a gel injected between the rectal-wall and the prostate. The optimal number of fields, as well as the most favorable energy, was evaluated in the context of the first approach with a simultaneous integrated boost. The third theme discusses the quality assurance (QA) that needs to be performed for an IMRT-SBRT technique. Three detectors that ara dedicated to the QA of dose distribution under accelerator were evaluated. The results of all these studies will be used for the implementation of a phase II study for prostate SBRT with an injection of hyaluronic acid between the rectum and the prostate.
7

Étude d'un système de transmission sur fibre optique plastique à saut d'indice

Thon-Adjalin, Carolle 18 April 2018 (has links)
La demande croissante pour des débits plus élevés a atteint la limite des solutions câblées actuelles. Dans ce contexte, la fibre optique plastique à saut d'indice (SI-FOP), avec son gros diamètre de câble (3 à 4 mm) et sa grande ouverture numérique semble être un candidat idéal pour la transmission du gigabit Ethernet à faible coût. Les avantages de la SI-FOP sont sa simplicité d'utilisation, sa connexion facile, l'installation à la portée de tous et sa longueur d'onde d'utilisation. Dans ce mémoire, nous déterminons un modèle mathématique réaliste de la SI-FOP dans un système à modulation d'intensité et détection directe (IM/DD) utilisant la modulation Discrete Multi Tone (DMT). Les caractéristiques du canal sont évaluées en déterminant la capacité théorique au sens de Shannon et la capacité pratique DMT avec les algorithmes d'allocation de bits (« rate adaptive bit loading ») comme le water-filling, les algorithmes de Chow et de Levin-Campello. Mots clés : fibre optique plastique, saut d'indice, modulation d'intensité, détection directe, modulation DMT, couplage de modes, « power flow equation », problèmes d'optimisation sous-contraintes, « rate adaptive water-filling », algorithme de Chow, algorithme de Levin-Campello, capacité théorique au sens de Shannon, capacité pratique DMT.
8

Study of different SOA structures impact on the transmission of IMDD OOFDM signals / Etudes de différentes structures SOA pour la transmission de l'IMDD OFDM

Hamze, Mohamad 09 June 2015 (has links)
Le travail de thèse porte sur une étude d'impact de différentes structures SOA sur la transmission optique de signaux OFDM modulés en intensité et reçus en détection directe (IMDD-OOFDM), dans le cadre des réseaux d'accès de nouvelle génération (σGPτσ). Dans la première partie du travail, nous avons d’abord validé expérimentalement la modélisation d’un RSτA sur une large plage d’utilisation. Ce modèle a ensuite été implémenté dans le cadre d'une plate-forme de co-simulation pour les systèmes de transmission IMDD-OOFDM et pour la conversion en longueur d'onde de signaux OOFDM avec une validation expérimentale. Une analyse approfondie des performances de transmission a été ensuite menée en termes de puissance optique et de longueur d’onde injectées, de longueur de fibre, de l’émission spontanée amplifiée (ASE), de la bande passante électrique et des non-linéarités du RSτA. Nous avons notamment montré théoriquement qu’une capacité minimale de transmission de 8,9 Gb/s sur 100 km pouvait être atteinte sur une plage de 100 nm avec le RSOA utilisé et avec l’aide d’une modulation adaptative (AMττFDM). Nous avons également démontré expérimentalement, pour la première fois à notre connaissance, la conversion de longueur d'onde de signaux optiques OOFDM-16QAM sur une plage de 70 nm en utilisant l'effet XGM du RSOA. Dans la seconde partie, nous avons développé la modélisation de plusieurs structures de SOA : un SOA à îlots quantiques (QD SOA), un SOA bi-électrodes et deux SOA cascadés en configuration contra-propagative. Nous avons étudiés leurs performances en transmission à l’aide de la modulation AMττFDM. Nous avons montré que ces structures présentent une capacité de transmission allant jusqu’à 30 Gb/s avec des distances de transmission jusqu'à 60 km. Nous avons montré également que le QD-SOA présente de meilleures performances en termes de capacité de transmission pour des distances allant jusqu'à 140 km en comparaison avec les deux autres configurations. / The thesis work deals with study of different SOA structures impact on the transmission of intensity modulation and direct detection OFDM signals in the context of the next generation access networks. In the first part of the work, we have experimentally validated a comprehensive wideband RSOA field model. It was the nused as part of a co-simulation platform for IMDD-OOFDM and OOFDM wavelength conversion transmission systems. Thanks to this co-simulation platform that presents good agreement with the measurement, and our experimental setup, we analyze the transmission performance in terms of optical input power, fiber length, ASEnoise, electrical bandwidth and RSOA nonlinearities. We showed by simulation that an AMOOFDM signal transmission over a 100 nm wavelength range with a minimum transmission capacity of 8.9 Gb/s for fiber lengths up to 100 km can be reached. Finally, we experimentally demonstrated, for the first time to the best of our knowledge, the feasibility of performing wave length conversion over 70 nm of OOFDM-16QAM optical signals using the XGM effect in an RSOA. In the second part of this work we develop a simplified quantum dot –SOA and two electrode SOAintensity modulator models and study their effect on a numerical OFDM IMDD transmission system, we also study a two cascaded SOA in a counter propagating configuration as an intensity modulator. We find that for the three configurations we can achieve a high transmission capacity of around 30 Gb/s for transmission distances up to 60 Km, we also find that the QD-SOA will have the best performance in terms of transmission capacity for distances up to 140 Km in comparison with the two other SOA configurations.
9

Développement d'un nouveau critère pour déterminer les limites d'utilisation des détecteurs en dosimétrie non standard

Kamio, Yuji 12 1900 (has links)
Depuis quelques années, il y a un intérêt de la communauté en dosimétrie d'actualiser les protocoles de dosimétrie des faisceaux larges tels que le TG-51 (AAPM) et le TRS-398 (IAEA) aux champs non standard qui requièrent un facteur de correction additionnel. Or, ces facteurs de correction sont difficiles à déterminer précisément dans un temps acceptable. Pour les petits champs, ces facteurs augmentent rapidement avec la taille de champ tandis que pour les champs d'IMRT, les incertitudes de positionnement du détecteur rendent une correction cas par cas impraticable. Dans cette étude, un critère théorique basé sur la fonction de réponse dosimétrique des détecteurs est développé pour déterminer dans quelles situations les dosimètres peuvent être utilisés sans correction. Les réponses de quatre chambres à ionisation, d'une chambre liquide, d'un détecteur au diamant, d'une diode, d'un détecteur à l'alanine et d'un détecteur à scintillation sont caractérisées à 6 MV et 25 MV. Plusieurs stratégies sont également suggérées pour diminuer/éliminer les facteurs de correction telles que de rapporter la dose absorbée à un volume et de modifier les matériaux non sensibles du détecteur pour pallier l'effet de densité massique. Une nouvelle méthode de compensation de la densité basée sur une fonction de perturbation est présentée. Finalement, les résultats démontrent que le détecteur à scintillation peut mesurer les champs non standard utilisés en clinique avec une correction inférieure à 1%. / In recent years, the radiation dosimetry community has shown a keen interest in extending broad beam dosimetry protocols such as AAPM's TG-51 and IAEA's TRS-398 to nonstandard fields which involve the use of an additional correction factor. Yet, these correction factors are difficult to determine precisely in a time frame that is acceptable. For small fields, these factors increase rapidly with field size, whereas for composite IMRT fields, detector positioning uncertainties render a case-by-case correction impractical. In this study, a theoretical criterion based on radiation detectors' dose response functions is used to determine in which situations a given dosimeter can be used without correction. The responses of four ionization chambers, a liquid-filled chamber, a diamond detector, an unshieded diode, an alanine dosimeter and a plastic scintillator detector are characterized at 6 MV and 25 MV. Several strategies are also suggested to reduce/eliminate correction factors such as reporting the absorbed dose to a volume and modifying the non-sensitive components of a detector to compensate for mass density effects. A new method of density compensation based on a perturbation function is presented. Finally, results show that the scintillator detector can measure nonstandard fields used in the clinic with corrections under 1%.
10

Développement d'un nouveau critère pour déterminer les limites d'utilisation des détecteurs en dosimétrie non standard

Kamio, Yuji 12 1900 (has links)
Depuis quelques années, il y a un intérêt de la communauté en dosimétrie d'actualiser les protocoles de dosimétrie des faisceaux larges tels que le TG-51 (AAPM) et le TRS-398 (IAEA) aux champs non standard qui requièrent un facteur de correction additionnel. Or, ces facteurs de correction sont difficiles à déterminer précisément dans un temps acceptable. Pour les petits champs, ces facteurs augmentent rapidement avec la taille de champ tandis que pour les champs d'IMRT, les incertitudes de positionnement du détecteur rendent une correction cas par cas impraticable. Dans cette étude, un critère théorique basé sur la fonction de réponse dosimétrique des détecteurs est développé pour déterminer dans quelles situations les dosimètres peuvent être utilisés sans correction. Les réponses de quatre chambres à ionisation, d'une chambre liquide, d'un détecteur au diamant, d'une diode, d'un détecteur à l'alanine et d'un détecteur à scintillation sont caractérisées à 6 MV et 25 MV. Plusieurs stratégies sont également suggérées pour diminuer/éliminer les facteurs de correction telles que de rapporter la dose absorbée à un volume et de modifier les matériaux non sensibles du détecteur pour pallier l'effet de densité massique. Une nouvelle méthode de compensation de la densité basée sur une fonction de perturbation est présentée. Finalement, les résultats démontrent que le détecteur à scintillation peut mesurer les champs non standard utilisés en clinique avec une correction inférieure à 1%. / In recent years, the radiation dosimetry community has shown a keen interest in extending broad beam dosimetry protocols such as AAPM's TG-51 and IAEA's TRS-398 to nonstandard fields which involve the use of an additional correction factor. Yet, these correction factors are difficult to determine precisely in a time frame that is acceptable. For small fields, these factors increase rapidly with field size, whereas for composite IMRT fields, detector positioning uncertainties render a case-by-case correction impractical. In this study, a theoretical criterion based on radiation detectors' dose response functions is used to determine in which situations a given dosimeter can be used without correction. The responses of four ionization chambers, a liquid-filled chamber, a diamond detector, an unshieded diode, an alanine dosimeter and a plastic scintillator detector are characterized at 6 MV and 25 MV. Several strategies are also suggested to reduce/eliminate correction factors such as reporting the absorbed dose to a volume and modifying the non-sensitive components of a detector to compensate for mass density effects. A new method of density compensation based on a perturbation function is presented. Finally, results show that the scintillator detector can measure nonstandard fields used in the clinic with corrections under 1%.

Page generated in 0.1321 seconds