• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Principles for Diverting and Merging Viscous Flows : Evaluation and Visualisation / Principer för Delning och Sammnföring av Viskösa Flöden : Utvärdering och Visualisering

Strese, Åke January 2017 (has links)
In the chemistry branch of science is often a chromatograph usedto separate and purify substances in a solution. In achromatograph, different detectors are used to analyse the samplesconstituents. Some detectors destroy the sample during analysis.Because it is undesirable to destroy the entire flow of sample, asmall mass is transferred to a second flow by a flow splitter. Inthis report, four principles to divert a small mass from one flowto another are developed and evaluated. The basic principles todivert the flows is tested and principal mock-ups are designed andmanufactured. A brief survey of the market is conducted and aproblem related to flow spitting is investigated. The problem isthe influence on yield through a chromatograph due to flowretaining. Designing and testing of different retaining systems isalso included in this report. All four initial principles proved to be plausible splittingtechniques. However, only two principles appeared to be feasiblefor direct implementation in devices comparable withchromatographs. One of the less feasible principle is covered byseveral patents. The other is difficult to manufacture in order tomeet the strict requirements associated with e.g. chromatographs.The testing of different retaining systems showed that smallertube inner diameter and how the tube is winded can reduce theretaining system influence on the yield significantly. The splitting techniques in this report are all feasible splittingtechniques, and the report can be used as a solid foundation fordevelopment future laboratory instruments. / Inom kemin förekommer ofta kromatografer för att rena och separera kemiska substanser iett prov. De separerade substanserna kan detekteras och analyseras av olika detektorer, därvissa detektorer förstör provet i analysprocessen. Då det oftast är önskvärt att bevara såmycket som möjligt av ett prov, för vidare studier, avleds därför en liten mängd av deseparerade substanserna till detektorn då en förstörande detektor används. I denna studieutvecklades och undersöktes fyra principer för att avleda mycket små volymer från ett flödetill ett annat. Flödesdelning och sammanförning med de grundläggande flödesdelningsprincipernatestades, principiella modeller konstruerades och tillverkades. Enmarknadsundersökning samt en undersökning av ett flödesdelningsassocierat probleminkluderas också i rapporten. Problemet består i minskning av utbyte på grund avbandbreddning i flödesfördröjningssystem. Bandbreddning studerades således i olika formerav flödesfördröjningssystem. Alla fyra principer visade sig vara möjliga flödesdelningstekniker varav två av sådan karaktäratt de skulle kunna realiseras i ett instrument såsom en kromatograf. Av de två andra omfattasden ena av flertalet patent och den andra skulle vara tillverkningstekniks svår att förverkligamed vedertagna tillverkningstekniker. Tester på olika typer avflödesfördröjningssystemutformningar visade att slangdimension och hur slangen är lindadhar stor inverkan på bandbreddning. Det återstår en hel del konceptuell utveckling då principerna bara behandlats pågrundläggande nivå. Genom de principiella modellerna ges en bild av hur principerna skullekunna förverkligas, men vidare ställningstaganden måste tas till bland annat materialval samtmonitorering och anpassning av flöden. Rapporten ger en god grund för framtidaproduktutveckling.
2

A Numerical Study of the Gas-Particle Flow in Pipework and Flow Splitting Devices of Coal-Fired Power Plant

Schneider, Helfried, Frank, Thomas, Pachler, Klaus, Bernert, Klaus 17 April 2002 (has links) (PDF)
In power plants using large utility coal-fired boilers for generation of electricity the coal is pulverised in coal mills and then it has to be pneumatically transported and distributed to a larger number of burners (e.g. 30-40) circumferentially arranged in several rows around the burning chamber of the boiler. Besides the large pipework flow splitting devices are necessary for distribution of an equal amount of pulverised fuel (PF) to each of the burners. So called trifurcators (without inner fittings or guiding vanes) and ''riffle'' type bifurcators are commonly used to split the gas-coal particle flow into two or three pipes/channels with an equal amount of PF mass flow rate in each outflow cross section of the flow splitting device. These PF flow splitting devices are subject of a number of problems. First of all an uneven distribution of PF over the burners of a large utility boiler leads to operational and maintenance problems, increased level of unburned carbon and higher rates of NOX emissions. Maldistribution of fuel between burners caused by non uniform concentration of the PF (particle roping) in pipe and channel bends prior to flow splitting devices leads to uncontrolled differences in the fuel to air ratio between burners. This results in localised regions in the furnace which are fuel rich, where insufficient air causes incomplete combustion of the fuel. Other regions in the furnace become fuel lean, forming high local concentrations of NOX due to the high local concentrations of O2. Otherwise PF maldistribution can impact on power plant maintenance in terms of uneven wear on PF pipework, flow splitters as well as the effects on boiler panels (PF deposition, corrosion, slagging). In order to address these problems in establishing uniform PF distribution over the outlet cross sections of flow splitting devices in the pipework of coal-fired power plants the present paper deals with numerical prediction and analysis of the complex gas and coal particle (PF) flow through trifurcators and ''riffle'' type bifurcators. The numerical investigation is based on a 3-dimensional Eulerian- Lagrangian approach (MISTRAL/PartFlow-3D) developed by Frank et al. The numerical method is capable to predict isothermal, incompressible, steady gas- particle flows in 3-dimensional, geometrically complex flow geometries using boundary fitted, block-structured, numerical grids. Due to the very high numerical effort of the investigated gas-particle flows the numerical approach has been developed with special emphasis on efficient parallel computing on clusters of workstations or other high performance computing architectures. Besides the aerodynamically interaction between the carrier fluid phase and the PF particles the gas-particle flow is mainly influenced by particle-wall interactions with the outer wall boundaries and the inner fittings and guiding vanes of the investigated flow splitting devices. In order to allow accurate quantitative prediction of the motion of the disperse phase the numerical model requires detailed information about the particle-wall collision process. In commonly used physical models of the particle-wall interaction this is the knowledge or experimental prediction of the restitution coefficients (dynamic friction coefficient, coefficient of restitution) for the used combination of particle and wall material, e.g. PF particles on steel. In the present investigation these parameters of the particle-wall interaction model have been obtained from special experiments in two test facilities. Basic experiments to clarify the details of the particle-wall interaction process were made in a test facility with a spherical disk accelerator. This test facility furthermore provides the opportunity to investigate the bouncing process under normal pressure as well as under vacuum conditions, thus excluding aerodynamically influences on the motion of small particles in the near vicinity of solid wall surfaces (especially under small angles of attack). In this experiments spherical glass beads were used as particle material. In a second test facility we have investigated the real impact of non-spherical pulverised fuel particles on a steel/ceramic target. In this experiments PF particles were accelerated by an injector using inert gas like e.g. CO2 or N2 as the carrier phase in order to avoid dust explosion hazards. The obtained data for the particle-wall collision models were compared to those obtained for glass spheres, where bouncing models are proofed to be valid. Furthermore the second test facility was used to obtain particle erosion rates for PF particles on steel targets as a function of impact angles and velocities. The results of experimental investigations has been incorporated into the numerical model. Hereafter the numerical approach MISTRAL/PartFlow-3D has been applied to the PF flow through a ''riffle'' type bifurcator. Using ICEM/CFD-Hexa as grid generator a numerical mesh with approximately 4 million grid cells has been designed for approximation of the complex geometry of the flow splitting device with all its interior fittings and guiding vanes. Based on a predicted gas flow field a large number of PF particles are tracked throughout the flow geometry of the flow-splitter. Besides mean quantities of the particle flow field like e.g. local particle concentrations, mean particle velocities, distribution of mean particle diameter, etc. it is now possible to obtain information about particle erosion on riffle plates and guiding vanes of the flow splitting device. Furthermore the influence of different roping patterns in front of the flow splitter on the uniformness of PF mass flow rate splitting after the bifurcator has been investigated numerically. Results show the efficient operation of the investigated bifurcator in absence of particle roping, this means under conditions of an uniform PF particle concentration distribution in the inflow cross section of the bifurcator. If particle roping occurs and particle concentration differs over the pipe cross section in front of the bifurcator the equal PF particle mass flow rate splitting can be strongly deteriorated in dependence on the location and intensity of the particle rope or particle concentration irregularities. The presented results show the importance of further development of efficient rope splitting devices for applications in coal-fired power plants. Numerical analysis can be used as an efficient tool for their investigation and further optimisation under various operating and flow conditions.
3

A Numerical Study of the Gas-Particle Flow in Pipework and Flow Splitting Devices of Coal-Fired Power Plant

Schneider, Helfried, Frank, Thomas, Pachler, Klaus, Bernert, Klaus 17 April 2002 (has links)
In power plants using large utility coal-fired boilers for generation of electricity the coal is pulverised in coal mills and then it has to be pneumatically transported and distributed to a larger number of burners (e.g. 30-40) circumferentially arranged in several rows around the burning chamber of the boiler. Besides the large pipework flow splitting devices are necessary for distribution of an equal amount of pulverised fuel (PF) to each of the burners. So called trifurcators (without inner fittings or guiding vanes) and ''riffle'' type bifurcators are commonly used to split the gas-coal particle flow into two or three pipes/channels with an equal amount of PF mass flow rate in each outflow cross section of the flow splitting device. These PF flow splitting devices are subject of a number of problems. First of all an uneven distribution of PF over the burners of a large utility boiler leads to operational and maintenance problems, increased level of unburned carbon and higher rates of NOX emissions. Maldistribution of fuel between burners caused by non uniform concentration of the PF (particle roping) in pipe and channel bends prior to flow splitting devices leads to uncontrolled differences in the fuel to air ratio between burners. This results in localised regions in the furnace which are fuel rich, where insufficient air causes incomplete combustion of the fuel. Other regions in the furnace become fuel lean, forming high local concentrations of NOX due to the high local concentrations of O2. Otherwise PF maldistribution can impact on power plant maintenance in terms of uneven wear on PF pipework, flow splitters as well as the effects on boiler panels (PF deposition, corrosion, slagging). In order to address these problems in establishing uniform PF distribution over the outlet cross sections of flow splitting devices in the pipework of coal-fired power plants the present paper deals with numerical prediction and analysis of the complex gas and coal particle (PF) flow through trifurcators and ''riffle'' type bifurcators. The numerical investigation is based on a 3-dimensional Eulerian- Lagrangian approach (MISTRAL/PartFlow-3D) developed by Frank et al. The numerical method is capable to predict isothermal, incompressible, steady gas- particle flows in 3-dimensional, geometrically complex flow geometries using boundary fitted, block-structured, numerical grids. Due to the very high numerical effort of the investigated gas-particle flows the numerical approach has been developed with special emphasis on efficient parallel computing on clusters of workstations or other high performance computing architectures. Besides the aerodynamically interaction between the carrier fluid phase and the PF particles the gas-particle flow is mainly influenced by particle-wall interactions with the outer wall boundaries and the inner fittings and guiding vanes of the investigated flow splitting devices. In order to allow accurate quantitative prediction of the motion of the disperse phase the numerical model requires detailed information about the particle-wall collision process. In commonly used physical models of the particle-wall interaction this is the knowledge or experimental prediction of the restitution coefficients (dynamic friction coefficient, coefficient of restitution) for the used combination of particle and wall material, e.g. PF particles on steel. In the present investigation these parameters of the particle-wall interaction model have been obtained from special experiments in two test facilities. Basic experiments to clarify the details of the particle-wall interaction process were made in a test facility with a spherical disk accelerator. This test facility furthermore provides the opportunity to investigate the bouncing process under normal pressure as well as under vacuum conditions, thus excluding aerodynamically influences on the motion of small particles in the near vicinity of solid wall surfaces (especially under small angles of attack). In this experiments spherical glass beads were used as particle material. In a second test facility we have investigated the real impact of non-spherical pulverised fuel particles on a steel/ceramic target. In this experiments PF particles were accelerated by an injector using inert gas like e.g. CO2 or N2 as the carrier phase in order to avoid dust explosion hazards. The obtained data for the particle-wall collision models were compared to those obtained for glass spheres, where bouncing models are proofed to be valid. Furthermore the second test facility was used to obtain particle erosion rates for PF particles on steel targets as a function of impact angles and velocities. The results of experimental investigations has been incorporated into the numerical model. Hereafter the numerical approach MISTRAL/PartFlow-3D has been applied to the PF flow through a ''riffle'' type bifurcator. Using ICEM/CFD-Hexa as grid generator a numerical mesh with approximately 4 million grid cells has been designed for approximation of the complex geometry of the flow splitting device with all its interior fittings and guiding vanes. Based on a predicted gas flow field a large number of PF particles are tracked throughout the flow geometry of the flow-splitter. Besides mean quantities of the particle flow field like e.g. local particle concentrations, mean particle velocities, distribution of mean particle diameter, etc. it is now possible to obtain information about particle erosion on riffle plates and guiding vanes of the flow splitting device. Furthermore the influence of different roping patterns in front of the flow splitter on the uniformness of PF mass flow rate splitting after the bifurcator has been investigated numerically. Results show the efficient operation of the investigated bifurcator in absence of particle roping, this means under conditions of an uniform PF particle concentration distribution in the inflow cross section of the bifurcator. If particle roping occurs and particle concentration differs over the pipe cross section in front of the bifurcator the equal PF particle mass flow rate splitting can be strongly deteriorated in dependence on the location and intensity of the particle rope or particle concentration irregularities. The presented results show the importance of further development of efficient rope splitting devices for applications in coal-fired power plants. Numerical analysis can be used as an efficient tool for their investigation and further optimisation under various operating and flow conditions.

Page generated in 0.0797 seconds