• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 272
  • 56
  • 27
  • 3
  • 1
  • Tagged with
  • 361
  • 166
  • 58
  • 56
  • 41
  • 32
  • 31
  • 28
  • 28
  • 25
  • 22
  • 21
  • 20
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Identificação da procedência geográfica da erva mate (llex paraguariensis) mediante análise elementar, reflexão no infravermelho próximo e quimiometria

Marcelo, Marcelo Caetano Alexandre January 2013 (has links)
Neste trabalho foi desenvolvido um método de análise de erva mate mediante as técnicas de espectroscopia no infravermelho próximo (NIR), espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massa com plasma indutivamente acoplado (ICP-MS), com o intuito de classificar a erva mate por país de origem da América do Sul. Para isto, foram utilizados métodos de análise multivariada supervisionada e não supervisionada, como a análise hierárquica por agrupamentos (HCA), a análise por componentes principais (PCA), o método do k-ésimo vizinho mais próximo (kNN), soft independent modeling class analogy (SIMCA), análise discriminante por mínimos quadrados parciais (PLS-DA) e análise discriminante por máquinas de vetor de suporte (SVM-DA). Foram analisadas 54 amostras de erva mate provenientes da América do Sul (Argentina, Brasil, Paraguai e Uruguai). As amostras foram cominuídas em moinho criogênico e diretamente analisadas para a obtenção dos espectros de reflexão no NIR. Para a determinação dos elementos Ca, K, Mg, Al, Fe, Mn, Ba, Cu, P, Sr e Zn por ICP OES e Li, Be, Ti, V, Cr, Ni, Co, As, Se, Rb, Mo, Ag, Cd, Sb, La, Ce, Pb, Bi e U por ICP-MS, foi realizada a decomposição das amostras por via úmida em bloco digestor em sistema fechado. A classificação da erva mate por país de origem foi possível, sendo que a melhor classificação para todos os métodos de análise multivariada foi obtida por NIR e para as concentrações dos elementos avaliados, a SVM-DA foi o melhor. Conclui-se que a erva mate pode ser avaliada por país de origem mediante a técnicas de ICP OES, ICP-MS e NIR. / A method of yerba mate analyzis using near infrared spectroscopy (NIR), inductively coupled plasma optical emission spectrometry ( ICP OES ) and inductively coupled plasma mass spectrometry (ICP-MS) was developed in order to classify yerba mate by country of origin in South America. To this end, principal components analysis (PCA), k-nearest neighbor (KNN), soft independent modeling class analogy (SIMCA), partial least square discriminant analysis (PLSDA), discriminant analysis by vector machine (SVM-DA) were used for multivariate analysis of the NIR spectra and element concentrations found in 54 samples of yerba mate from South America (Argentina, Brazil, Paraguay and Uruguay ). The samples were ground in cryogenic mill and directly analyzed in order to obtain the reflectance spectra in the NIR region. For elements determination (Ca, K, Mg, Al, Fe, Mn, Ba, Cu, P, Sr and Zn by ICP OES and Li, Be, Ti, V, Cr, Ni, Co, As, Se, Rb, Mo, Ag, Cd, Sb, La, Ce, Pb, Bi and U by ICP-MS), the samples were acid digested in closed vessel in digestion block. The classification of the yerba mate by country of origin was possible, whereas the best classification using all multivariate analysis methods was obtained for NIR. For the element concentrations, the best classification was obtained by SVM-DA. It was concluded that yerba mate classification by country of origin can be assessed through ICP OES, ICP-MS and NIR.
82

Desenvolvimento de metodologia para quantificação de elementos-traço em petróleo usando espectrômetro de massa de duplo foco com plasma indutivamente acoplado (ICP-MS de duplo foco)

Poletti, Jucelaine January 2014 (has links)
Neste trabalho, a quantificação de elementos-traço em petróleo foi efetuada empregando-se ICP-MS de duplo foco após o estudo de diferentes métodos de decomposição de amostras. A solução resultante obtida após a decomposição por via úmida em sistema fechado com aquecimento por radiação micro-ondas foi, também, utilizada para avaliar a formação de espécies poliatômicas no plasma. Os resultados obtidos permitiram a escolha de um modo de resolução adequado para quantificação dos analitos sem interferência das espécies poliatômicas. Desta forma, os isótopos 7Li, 24Mg, 47Ti, 51V, 52Cr, 56Fe, 59Co, 60Ni, 63Cu, 75As, 88Sr, 96Mo, 98Mo e 111Cd foram monitorados para a quantificação destes elementos no petróleo utilizando o espectrômetro nos modos de baixa e média resolução. A exatidão foi avaliada mediante análise de materiais de referência certificados, sendo observada concordância superior a 95% entre os valores certificados e os encontrados para a maioria dos elementos. Comparando-se os resultados obtidos para os diferentes métodos de preparo de amostras, foi observado que a decomposição em sistema fechado com aquecimento por radiação micro-ondas foi a mais eficiente na oxidação dos compostos orgânicos. Neste caso o carbono residual nos digeridos foi de cerca de 12%, com o uso de uma mistura de ácido nítrico e peróxido de hidrogênio. Adicionalmente, a decomposição por via seca e a diluição com solvente orgânico também foram avaliadas, para as quais foram observados alguns inconvenientes, como volatilização de analitos e deposição de carbono na interface do espectrômetro, respectivamente. Os limites de detecção foram inferiores a 10 ng g-1 para a maioria dos elementos avaliados. / In this work, the quantification of trace elements in crude oil was performed using a double focusing ICP-MS after evaluation of digestion methods. The resultant solution obtained after wet digestion in closed vessels by microwave heating was also used to evaluate interferences caused by polyatomic species on plasma. These results allowed the choice of suitable resolution on double focusing ICP-MS to avoid the polyatomic interferences. The isotopes 7Li, 24Mg, 47Ti, 51V, 52Cr, 56Fe, 59Co, 60Ni, 63Cu, 75As, 88Sr, 96Mo, 98Mo and 111Cd were used to these elements quantification in crude oil sample using the spectrometer in low and medium resolution. Accuracy was evaluated using certified reference materials and results better than 95% were obtained. Comparing the methods used for sample digestion it was observed that high efficiency of oxidation of organic compounds was obtained when wet digestion in closed vessels under microwave heating was used and residual carbon content in digests was about 12% using a mixture of nitric acid and hydrogen peroxide. Additionally, dry ashing and dilution of samples in organic solvents methods were also evaluated and some inconvenients were observed as analytes volatilization and carbon deposition in the interface of the spectrometer, respectively. Limits of detection were lower than 10 ng g-1 for most of analytes.
83

Desenvolvimento de métodos analíticos para a determinação de lantanídeos por técnicas de espectrometria atômica com plasma indutivamente acoplado

Bentlin, Fabrina Regia Stumm January 2012 (has links)
Neste trabalho foram desenvolvidos métodos analíticos para a determinação de lantanídeos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massa com fonte de plasma indutivamente acoplado (ICP-MS) em diferentes tipos de matrizes: cinza de carvão, sedimento de rio, sedimento do Tibet, fluorita, pilha recarregável do tipo NiMH, água do mar, água doce e vinho tinto. Três diferentes nebulizadores foram investigados para a introdução da amostra no plasma (os nebulizadores microconcêntrico, ultrassônico e pneumático com dessolvatação do aerossol foram comparados). Nas determinações por ICP OES foram monitoradas, pelo menos, duas linhas espectrais por elemento e avaliadas a vazão do gás de nebulização e potência de radiofrequência. Dependendo da matriz da amostra, linhas espectrais adicionais foram monitoradas, devido a interferências da matriz. A vazão do gás de nebulização e a potência de radiofrequência aplicada ao plasma foram variadas conforme o elemento medido e o nebulizador utilizado, tanto para ICP OES quanto para ICP-MS. As interferências causadas pela matriz de cinza de carvão e água do mar foram menores quando foi utilizado o nebulizador ultrassônico. A precisão e exatidão também foram melhores para a maioria dos elementos, quando utilizada a nebulização ultrassônica. Para ambas as técnicas, ICP OES e ICP-MS, os melhores limites de detecção (LDs) foram obtidos mediante os nebulizadores ultrassônico e pneumático com dessolvatação do aerossol. Em relação aos procedimentos de preparo da amostra avaliados para a cinza de carvão, sedimento de rio e sedimento do Tibet, melhores resultados foram obtidos quando se empregou mistura composta por HNO3, HF e H2O2 para decompor a amostra, com posterior adição de H3BO3. No entanto, para a amostra de fluorita a fusão alcalina foi mais eficiente. Já para a pilha NiMH (matriz composta por metais e carbono) a decomposição com água-régia mostrou-se mais eficiente. O procedimento de pré-concentração dos lantanídeos mediante extração no ponto nuvem, utilizando-se como agente complexante o 1-(2-tenoil)-3,3,3-trifluoracetona (2-TTA) e como surfactante o octilfenoxipolietoxietanol (Triton X-114) mostrou-se restrito para amostras de água doce. Isto porque há interferência da matriz na formação dos complexos dos lantanídeos na presença de constituintes de matrizes mais complexas. Também foi desenvolvida metodologia para separação da matriz/pré-concentração dos lantanídeos utilizando-se minicoluna empacotada com 8-HQ (8-hidroxiquinolina imobilizada em vidro de porosidade controlada), com o intuito de diminuir as interferências causadas pela matriz água do mar. Parâmetros tais como pH da amostra, concentração do eluente, vazão da amostra e vazão de eluente foram avaliados. Os limites de detecção obtidos variaram entre 0,42 a 0,09 ηg L-1, enquanto que o fator de enriquecimento variou de 2,06 a 3,68. O método mostrou-se eficiente, com boa precisão (desvio padrão relativo entre 2,5 a 10%) e exatidão (recuperação entre 88 a 98%). Para cada ciclo de pré-concentração foram utilizados 3 mL da amostra e o tempo de pré-concentração e determinação foi 8 minutos. O efeito de matriz e do solvente orgânico com respeito à determinação dos lantanídeos foi também investigado mediante análise de vinho. A amostra de vinho tinto foi preparada através de sonicação e digestão ácida. Os melhores resultados foram obtidos mediante sonicação com sonda por 90 s e a amostra diluída 10 vezes. Neste caso, a solução da amostra de vinho foi introduzida no plasma mediante sistema de injeção em fluxo (FI) acoplado ao nebulizador pneumático com sistema de dessolvatação. Mediante análise multivariada os vinhos puderam ser discriminados de acordo com os países de origem na América do Sul, independentemente do tipo da uva, com exceção dos vinhos chilenos. / This work deals with the development of methods for lanthanides determination by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) in different matrices: coal fly ash, river sediment, Tibet sediment, sea water, fluorite, nickel-metal hydride (NiMH) battery, fresh water and red wine. Three different nebulizers were investigated for sample introduction into the plasma (pneumatic nebulizer, ultrasonic nebulizer and pneumatic nebulizer/aerosol desolvation were compared). Two spectral lines per element were at least monitored for determinations using ICP OES. The nebulizer gas flow rate and plasma power were evaluated. Depending on the sample, additional spectral lines needed to be monitored due to matrix interference. The nebulizer gas flow rate and RF power applied varied according to the element measured and nebulizer used, for both ICP OES and ICP-MS techniques. Matrix interference caused by coal fly ash and sea water was lower when ultrasonic nebulization was used. The precision and accuracy were also better for most elements by using ultrasonic nebulization. For both ICP OES and ICP-MS techniques, better limits of detection (LODs) were obtained using ultrasonic nebulization and pneumatic nebulization/aerosol desolvation. In relation to the sample preparation procedures evaluated for coal fly ash, river sediment and Tibet sediment, better results were obtained when HNO3, HF and H2O2 were used followed by addition of H3BO3. However, fluorite was more efficiently decomposed by using alkaline fusion. On the other hand, aqua regia was more efficient for nickel-metal hydride (NiMH) batteries decomposition. Pre-concentration of lanthanides by cloud point extraction, using 1-(2-thenoyl)-3,3,3-trifluoraceton (2-TTA) as complexant and octylphenoxypolyethoxyethanol (Triton X-114) as surfactant, revealed to be feasible only for lanthanides in fresh water. Matrix interference was observed for others materials and samples. Matrix separation/pre-concentration of lanthanides using minicolumn packed with 8-HQ (8-hydroxyquinoline immobilized on controlled pore glass) was also investigated. Parameters such as pH, eluent concentration, sample and eluent flow rate were evaluated. The LODs obtained ranged from 0.42 to 0.09 ηg L-1, while the enrichment factor ranged from 2.06 to 3.68. The method proved to be efficient, with good precision (relative standard deviation between 2.5 and 10%) and accuracy (recovery between 88 to 98%). For each cycle of pre-concentration 3 mL of sample were used, while the time needed for pre-concentration and determination was 8 minutes. The effect of matrix and organic solvent with respect to lanthanides determination using ICP-MS was also investigated by analysis of red wine. Ultrasound and acid digestion were used for sample preparation. Best results were obtained by sonication with a probe for 90 s and sample 10-fold diluted. The wine sample solution was introduced into the plasma using flow injection (FI) and pneumatic nebulization/aerosol desolvation. By multivariate analysis the wines could be discriminated according to the country of origin in South America, regardless of the type of grape, with the exception of Chilean wines.
84

Um método de identificação de fontes de vibração em vigas. / A method of identification of sources of vibrations in beams.

Luis Flávio Soares Nunes 22 November 2012 (has links)
Neste trabalho, procuramos resolver o problema direto da equação da viga de Euler- Bernoulli bi-engastada com condições iniciais nulas. Estudamos o problema inverso da viga, que consiste em identificar a fonte de vibração, modelada como um elemento em L2, usando como dado a velocidade de um ponto arbitrário da viga, durante um intervalo de tempo arbitrariamente pequeno. A relevância deste trabalho na Engenharia encontra-se, por exemplo, na identificação de danos estruturais em vigas. / In this work, we try to solve the direct problem of the clamped-clamped Euler- Bernoulli beam equation, with zero initial conditions. We study the inverse problem of the beam, consisting in the identification of the source of vibration, shaped as an element in L2, using as data the speed from an arbitrary point of the beam, during a time interval arbitrarily small. The relevance of this work in Engineering, for example, is in the identification of structural damage in beams.
85

Desenvolvimento de métodos analíticos para a determinação de lantanídeos por técnicas de espectrometria atômica com plasma indutivamente acoplado

Bentlin, Fabrina Regia Stumm January 2012 (has links)
Neste trabalho foram desenvolvidos métodos analíticos para a determinação de lantanídeos por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massa com fonte de plasma indutivamente acoplado (ICP-MS) em diferentes tipos de matrizes: cinza de carvão, sedimento de rio, sedimento do Tibet, fluorita, pilha recarregável do tipo NiMH, água do mar, água doce e vinho tinto. Três diferentes nebulizadores foram investigados para a introdução da amostra no plasma (os nebulizadores microconcêntrico, ultrassônico e pneumático com dessolvatação do aerossol foram comparados). Nas determinações por ICP OES foram monitoradas, pelo menos, duas linhas espectrais por elemento e avaliadas a vazão do gás de nebulização e potência de radiofrequência. Dependendo da matriz da amostra, linhas espectrais adicionais foram monitoradas, devido a interferências da matriz. A vazão do gás de nebulização e a potência de radiofrequência aplicada ao plasma foram variadas conforme o elemento medido e o nebulizador utilizado, tanto para ICP OES quanto para ICP-MS. As interferências causadas pela matriz de cinza de carvão e água do mar foram menores quando foi utilizado o nebulizador ultrassônico. A precisão e exatidão também foram melhores para a maioria dos elementos, quando utilizada a nebulização ultrassônica. Para ambas as técnicas, ICP OES e ICP-MS, os melhores limites de detecção (LDs) foram obtidos mediante os nebulizadores ultrassônico e pneumático com dessolvatação do aerossol. Em relação aos procedimentos de preparo da amostra avaliados para a cinza de carvão, sedimento de rio e sedimento do Tibet, melhores resultados foram obtidos quando se empregou mistura composta por HNO3, HF e H2O2 para decompor a amostra, com posterior adição de H3BO3. No entanto, para a amostra de fluorita a fusão alcalina foi mais eficiente. Já para a pilha NiMH (matriz composta por metais e carbono) a decomposição com água-régia mostrou-se mais eficiente. O procedimento de pré-concentração dos lantanídeos mediante extração no ponto nuvem, utilizando-se como agente complexante o 1-(2-tenoil)-3,3,3-trifluoracetona (2-TTA) e como surfactante o octilfenoxipolietoxietanol (Triton X-114) mostrou-se restrito para amostras de água doce. Isto porque há interferência da matriz na formação dos complexos dos lantanídeos na presença de constituintes de matrizes mais complexas. Também foi desenvolvida metodologia para separação da matriz/pré-concentração dos lantanídeos utilizando-se minicoluna empacotada com 8-HQ (8-hidroxiquinolina imobilizada em vidro de porosidade controlada), com o intuito de diminuir as interferências causadas pela matriz água do mar. Parâmetros tais como pH da amostra, concentração do eluente, vazão da amostra e vazão de eluente foram avaliados. Os limites de detecção obtidos variaram entre 0,42 a 0,09 ηg L-1, enquanto que o fator de enriquecimento variou de 2,06 a 3,68. O método mostrou-se eficiente, com boa precisão (desvio padrão relativo entre 2,5 a 10%) e exatidão (recuperação entre 88 a 98%). Para cada ciclo de pré-concentração foram utilizados 3 mL da amostra e o tempo de pré-concentração e determinação foi 8 minutos. O efeito de matriz e do solvente orgânico com respeito à determinação dos lantanídeos foi também investigado mediante análise de vinho. A amostra de vinho tinto foi preparada através de sonicação e digestão ácida. Os melhores resultados foram obtidos mediante sonicação com sonda por 90 s e a amostra diluída 10 vezes. Neste caso, a solução da amostra de vinho foi introduzida no plasma mediante sistema de injeção em fluxo (FI) acoplado ao nebulizador pneumático com sistema de dessolvatação. Mediante análise multivariada os vinhos puderam ser discriminados de acordo com os países de origem na América do Sul, independentemente do tipo da uva, com exceção dos vinhos chilenos. / This work deals with the development of methods for lanthanides determination by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) in different matrices: coal fly ash, river sediment, Tibet sediment, sea water, fluorite, nickel-metal hydride (NiMH) battery, fresh water and red wine. Three different nebulizers were investigated for sample introduction into the plasma (pneumatic nebulizer, ultrasonic nebulizer and pneumatic nebulizer/aerosol desolvation were compared). Two spectral lines per element were at least monitored for determinations using ICP OES. The nebulizer gas flow rate and plasma power were evaluated. Depending on the sample, additional spectral lines needed to be monitored due to matrix interference. The nebulizer gas flow rate and RF power applied varied according to the element measured and nebulizer used, for both ICP OES and ICP-MS techniques. Matrix interference caused by coal fly ash and sea water was lower when ultrasonic nebulization was used. The precision and accuracy were also better for most elements by using ultrasonic nebulization. For both ICP OES and ICP-MS techniques, better limits of detection (LODs) were obtained using ultrasonic nebulization and pneumatic nebulization/aerosol desolvation. In relation to the sample preparation procedures evaluated for coal fly ash, river sediment and Tibet sediment, better results were obtained when HNO3, HF and H2O2 were used followed by addition of H3BO3. However, fluorite was more efficiently decomposed by using alkaline fusion. On the other hand, aqua regia was more efficient for nickel-metal hydride (NiMH) batteries decomposition. Pre-concentration of lanthanides by cloud point extraction, using 1-(2-thenoyl)-3,3,3-trifluoraceton (2-TTA) as complexant and octylphenoxypolyethoxyethanol (Triton X-114) as surfactant, revealed to be feasible only for lanthanides in fresh water. Matrix interference was observed for others materials and samples. Matrix separation/pre-concentration of lanthanides using minicolumn packed with 8-HQ (8-hydroxyquinoline immobilized on controlled pore glass) was also investigated. Parameters such as pH, eluent concentration, sample and eluent flow rate were evaluated. The LODs obtained ranged from 0.42 to 0.09 ηg L-1, while the enrichment factor ranged from 2.06 to 3.68. The method proved to be efficient, with good precision (relative standard deviation between 2.5 and 10%) and accuracy (recovery between 88 to 98%). For each cycle of pre-concentration 3 mL of sample were used, while the time needed for pre-concentration and determination was 8 minutes. The effect of matrix and organic solvent with respect to lanthanides determination using ICP-MS was also investigated by analysis of red wine. Ultrasound and acid digestion were used for sample preparation. Best results were obtained by sonication with a probe for 90 s and sample 10-fold diluted. The wine sample solution was introduced into the plasma using flow injection (FI) and pneumatic nebulization/aerosol desolvation. By multivariate analysis the wines could be discriminated according to the country of origin in South America, regardless of the type of grape, with the exception of Chilean wines.
86

Investigação do comportamento de modificadores químicos para fósforo em forno de grafite usando espectrometria de absorção atômica de fonte de linha e fonte contínua de alta resolução

Dessuy, Morgana Bazzan January 2007 (has links)
Neste trabalho espectrometria de absorção atômica de fonte de linha (LS AAS) e de fonte contínua com alta resolução (HR-CS AAS) foram empregadas para investigar alguns modificadores, citados na literatura, para a determinação de fósforo usando forno de grafite. Modificadores químicos são necessários para produzir fósforo atômico e evitar a formação de subóxidos e outras moléculas voláteis. Com o emprego da HR-CS AAS ficou claro que, sem a adição de modificador, átomos de fósforo são formados somente numa reação secundária na parede do tubo. A medida de absorção, no início da fase de atomização, é inteiramente devido à molécula de PO. Paládio, paládio misturado com cálcio e lantânio, propostos como modificadores químicos para determinação de fósforo, foram os que produziram predominantemente fósforo atômico. Estes modificadores levaram, ainda a uma maior sensibilidade, em comparação com aquela obtida quando fluoreto de sódio foi empregado. O corretor de fundo de deutério não é capaz de corrigir eficientemente o fundo estruturado devido à PO, conseqüentemente, muitos dos resultados obtidos com LS AAS são artefatos. Constatou-se que HR-CS AAS é uma ferramenta bastante adequada para elucidar o comportamento do fósforo, podendo ser aplicada para outros elementos, pois toda a vizinhança da linha analítica é visível à alta resolução. / In this work line-source (LS) and high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) have been used to investigate some modifiers recommended in the literature for the determination phosphorus in a graphite furnace. Modifiers are necessary to produce phosphorus atoms and to avoid the formation of volatile suboxides and other molecules. Using HR-CS AAS it has been found that, without the addition of a modifier, phosphorus atoms are only formed in a secondary reaction on the wall of the graphite tube. The absorption measured at the beginning of the atomization stage is not due to phosphorus atoms, but to the PO molecule. Palladium, with or without the addition of calcium, and lanthanum, used as modifiers, produced predominantly atomic phosphorus. With these modifiers the sensitivity was also higher than that obtained with the sodium fluoride modifier. Deuterium background correction is not capable of correcting efficiently for the structured background due to PO and, consequently, many of the results obtained with LS AAS are artifacts. HR-CS AAS has been found to be an extremely useful tool to elucidate the behavior of phosphorus, and it might be equally useful for other analytes due to the visibility of the vicinity of the analytical line at high resolution.
87

Desenvolvimento de metodologia para quantificação de elementos-traço em petróleo usando espectrômetro de massa de duplo foco com plasma indutivamente acoplado (ICP-MS de duplo foco)

Poletti, Jucelaine January 2014 (has links)
Neste trabalho, a quantificação de elementos-traço em petróleo foi efetuada empregando-se ICP-MS de duplo foco após o estudo de diferentes métodos de decomposição de amostras. A solução resultante obtida após a decomposição por via úmida em sistema fechado com aquecimento por radiação micro-ondas foi, também, utilizada para avaliar a formação de espécies poliatômicas no plasma. Os resultados obtidos permitiram a escolha de um modo de resolução adequado para quantificação dos analitos sem interferência das espécies poliatômicas. Desta forma, os isótopos 7Li, 24Mg, 47Ti, 51V, 52Cr, 56Fe, 59Co, 60Ni, 63Cu, 75As, 88Sr, 96Mo, 98Mo e 111Cd foram monitorados para a quantificação destes elementos no petróleo utilizando o espectrômetro nos modos de baixa e média resolução. A exatidão foi avaliada mediante análise de materiais de referência certificados, sendo observada concordância superior a 95% entre os valores certificados e os encontrados para a maioria dos elementos. Comparando-se os resultados obtidos para os diferentes métodos de preparo de amostras, foi observado que a decomposição em sistema fechado com aquecimento por radiação micro-ondas foi a mais eficiente na oxidação dos compostos orgânicos. Neste caso o carbono residual nos digeridos foi de cerca de 12%, com o uso de uma mistura de ácido nítrico e peróxido de hidrogênio. Adicionalmente, a decomposição por via seca e a diluição com solvente orgânico também foram avaliadas, para as quais foram observados alguns inconvenientes, como volatilização de analitos e deposição de carbono na interface do espectrômetro, respectivamente. Os limites de detecção foram inferiores a 10 ng g-1 para a maioria dos elementos avaliados. / In this work, the quantification of trace elements in crude oil was performed using a double focusing ICP-MS after evaluation of digestion methods. The resultant solution obtained after wet digestion in closed vessels by microwave heating was also used to evaluate interferences caused by polyatomic species on plasma. These results allowed the choice of suitable resolution on double focusing ICP-MS to avoid the polyatomic interferences. The isotopes 7Li, 24Mg, 47Ti, 51V, 52Cr, 56Fe, 59Co, 60Ni, 63Cu, 75As, 88Sr, 96Mo, 98Mo and 111Cd were used to these elements quantification in crude oil sample using the spectrometer in low and medium resolution. Accuracy was evaluated using certified reference materials and results better than 95% were obtained. Comparing the methods used for sample digestion it was observed that high efficiency of oxidation of organic compounds was obtained when wet digestion in closed vessels under microwave heating was used and residual carbon content in digests was about 12% using a mixture of nitric acid and hydrogen peroxide. Additionally, dry ashing and dilution of samples in organic solvents methods were also evaluated and some inconvenients were observed as analytes volatilization and carbon deposition in the interface of the spectrometer, respectively. Limits of detection were lower than 10 ng g-1 for most of analytes.
88

Diferentes fontes de carbono no cultivo intensivo da tilápia do nilo Oreochromis niloticus (Linnaeus, 1758) em sistema de bioflocos

LIMA, Eduardo Cesar Rodrigues de 23 February 2016 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2017-10-23T12:50:42Z No. of bitstreams: 1 Eduardo Cesar Rodrigues de Lima.pdf: 493122 bytes, checksum: eef0aacc9225107f4ed820dd3b64829c (MD5) / Made available in DSpace on 2017-10-23T12:50:42Z (GMT). No. of bitstreams: 1 Eduardo Cesar Rodrigues de Lima.pdf: 493122 bytes, checksum: eef0aacc9225107f4ed820dd3b64829c (MD5) Previous issue date: 2016-02-23 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Biofloc technology has brought advances in traditional aquaculture, mainly in shrimp and tilapia. The main advantages are low water use, recycling of nitrogen compounds and production of supplementary food rich in protein. Various carbon sources are employed in the biofloc culture, as sugars, starches, alcohols and fibers. So the aim of this study was to evaluate the effects of organic carbon sources on water quality, growth performance and acceptance of Nile tilapia fillets (Oreochromis niloticus) cultured in biofloc systems. Were adopted three treatments involving the sources of carbon, as sugar (AÇU), liquid molasses (MEL) and powder molasses (MEP), with five replicates each and a control treatment (CTL) without biofloc, with four replications. Fish (72.6 g) were stocked in 19 circular tanks (800L) at a density of 35 fish/m3 and grown by 145 days. They evaluated the water quality variables, growth performance and acceptability of tilapia fillets. The dissolved oxygen concentration was significantly higher (P≤0.05) in the tanks without bioflocs (CTL) in the absence of bacterial biomass. Total ammonia nitrogen (NAT) showed statistical significance (P≤0.05) between the AÇU treatment and the other with bioflocs, displaying the lowest concentration of 2.53 mg NAT/L. Already nitrite, showed no statistical difference (P>0.05) among treatments with mean values ranging from 0.74 to 2.3 mg of N-NO2/L. The final weight ranged from 339 to 409 g, with feed conversion ratio between 1.61 and 1.89, survival 80-99% and showed no statistical difference between treatments (P>0.05). Productivity ranged from 9.72 (AÇU) to 14.22 Kg/m3 (CTL) (P≤0.05). The tanks without bioflocs (CTL) consumed 9 m3 of water to produce 1 kg of fish, while the bioflocs used only 0.68 m3, which represents a 13 times lower consumption. The percentage of protein in fillets of tilapia and analyzed bioflocs ranged respectively 17-20% and 31-33%.Tilapia fillets coming from biofloc with sugar showed to have the preference of the evaluators, with note 7.77 (like moderately to like very much). With these results, it is concluded that the carbon sources (molasses and sugar) can be used in the tilapia culture with biofloc without damage to water culture and productivity. Moreover, one should consider the ease of obtaining sugar. / A tecnologia de bioflocos tem apresentado avanços na aquicultura tradicional, principalmente, em camarões e tilápias. As principais vantagens são pouca utilização de água, reciclagem dos compostos nitrogenados e produção de alimento suplementar rico em proteína. Diversas fontes de carbono são empregadas no cultivo em bioflocos, açúcares, amidos, álcoois e fibras, assim, o objetivo deste trabalho foi avaliar os efeitos das fontes de carbono orgânico na qualidade da água, desempenho de crescimento e aceitação de filés da tilápia do Nilo (Oreochromis niloticus) cultivada em sistema de bioflocos. Foram adotados três tratamentos envolvendo as fontes de carbono açúcar (AÇU), melaço líquido (MEL) e melaço em pó (MEP), com cinco repetições cada e um tratamento controle (CTL) sem bioflocos, com quatro repetições. Os peixes (72,6 g) foram estocados em 19 tanques circulares (800L) numa densidade de 35 peixes/m3 e cultivados por 145 dias. Foram avaliadas as variáveis de qualidade da água, desempenho de crescimento e aceitabilidade dos filés de tilápia. A concentração de oxigênio dissolvido foi significativamente maior (P≤0,05) nos tanques sem bioflocos (CTL) devido à ausência de biomassa bacteriana. O nitrogênio da amônia total (NAT) apresentou diferença estatística (P≤0,05) entre o tratamento AÇU e os demais com bioflocos, exibindo a menor concentração de 2,53 mg NAT/L. Já o nitrito, não apresentou diferença estatística (P>0,05) entre os tratamentos com valores médios variando de 0,74 a 2,3 mg de N-NO2/L. O peso final variou de 339 a 409 g, com fator de conversão alimentar entre 1,61 e 1,89, sobrevivência de 80 a 99% e não apresentou diferença estatística entre os tratamentos (P>0,05). A produtividade variou de 9,72 (AÇU) a 14,22 Kg/m3 (CTL) (P≤0,05). Os tanques sem bioflocos (CTL) consumiram 9 m3 de água para produzir 1 Kg de peixe, enquanto os de bioflocos utilizaram apenas 0,68 m3, o que representa um consumo 13 vezes menor. A porcentagem de proteína nos filés de tilápia e nos bioflocos analisados variaram, respectivamente, de 17 a 20% e 31 a 33%. Os filés de tilápia oriundos do biofloco com açúcar mostraram ter a preferência dos avaliadores, com nota 7,77 (gostei moderadamente a gostei muito). Com estes resultados, conclui-se que as fontes de carbono utilizadas (melaços e açúcar) podem ser utilizadas no cultivo da tilápia O. niloticus em bioflocos sem prejuízos à água de cultivo e à produtividade. Além disso, deve-se considerar a facilidade na obtenção do açúcar.
89

Uso de geradores eólicos de pequeno porte para irrigação no semi-árido do estado de Sergipe

Leão Filho, Agnaldo Dias 23 April 2007 (has links)
The renewable sources of energies are shown as an interesting alternative to minimize the problem of the electric power lack faced by the rural man, mainly in the remote places where the difficulties of distribution of the electrification lines, above all in the economical aspect, they are big being shown unviable. The energy eolic besides other purposes, can be taken advantage of in bombs of water for irrigation. Like this, enormous amount of energy consumed for bombeament of water can be saved by the introduction of bombs of Catavento, because it is a consolidated technology, no pollutant and through studies, it was already proven that the bombeament of water using the speed of pumping of Catavento is very economical. This Dissertation intends to present, starting from a concept of maintainable development anchored in seven dimensions of the sustentabilidade (ecological, economical, social, space, cultural, technological and politics), a project of generators eolics of small load, developing to leave of that project, a group of criteria capable to contribute for evaluation of the viability of the same. It is also presented an example of project of energy eolic, that seeks to reduce the energy dependence in the agriculture and to contribute for the superation of the current problems of provisioning of the energy section. Finally, these criteria are tested to analyze the viability of this alternative project and the applicability of this technology, with the purpose of increasing the exploration of that type of alternative energy, promoting the maintainable development and benefitting the small producer. As result, was ended that the volume of water pumped by Catavento is enough for small overhead irrigations, storage in reservoirs for a subsequent use for gravity or to have his/her direct use for the human consumption or of animals always depending on the height manometric and of the amount of water requested by the user. . / As fontes renováveis de energias mostram-se como uma alternativa interessante para minimizar o problema da falta de energia elétrica enfrentada pelo homem rural, principalmente nos locais remotos onde as dificuldades de distribuição das linhas de eletrificação, sobretudo no aspecto econômico, são grandes mostrando-se inviáveis. A energia eólica além de outros propósitos pode ser aproveitada em bombas d'água para irrigação. Assim, enorme quantidade de energia consumida para bombeamento d'água pode ser poupada pela introdução de bombas de Catavento, pois é uma tecnologia consolidada, não poluente e através de estudos, já foi provado que o bombeamento d'água usando a velocidade de bombear do Catavento é muito econômico. Esta Dissertação pretende apresentar, a partir de um conceito de desenvolvimento sustentável ancorado em sete dimensões da sustentabilidade (ecológica, econômica, social, espacial, cultural, tecnológica e política), um projeto de geradores eólicos de pequeno porte, desenvolvendo a partir desse projeto, um conjunto de critérios capazes de contribuir para avaliação da viabilidade do mesmo. É também apresentado um exemplo de projeto de energia eólica, que visa reduzir a dependência energética na agricultura e contribuir para a superação dos atuais problemas de abastecimento do setor energético. Por fim, estes critérios são testados para analisar a viabilidade deste projeto alternativo e a aplicabilidade desta tecnologia, com o propósito de aumentar a exploração desse tipo de energia alternativa, promovendo o desenvolvimento sustentável e beneficiando o pequeno produtor. Como resultado, concluiu-se que o volume de água bombeado pelo Catavento é suficiente para pequenos sistemas de irrigação, armazenamento em reservatórios para uma posterior utilização por gravidade ou ter o seu uso direto para o consumo humano ou de animais dependendo sempre da altura manométrica e da quantidade de água solicitada pelo usuário.
90

Um método de detecção de plágio em códigos-fonte para disciplinas iniciais de programação

Oliveira, Adria Menezes de 22 December 2016 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-05-16T20:37:33Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Adria M. Oliveira.pdf: 1391584 bytes, checksum: 57b9729c6b3e110a2a4a53cb2c62a068 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-05-16T20:37:47Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Adria M. Oliveira.pdf: 1391584 bytes, checksum: 57b9729c6b3e110a2a4a53cb2c62a068 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-05-16T20:38:01Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Adria M. Oliveira.pdf: 1391584 bytes, checksum: 57b9729c6b3e110a2a4a53cb2c62a068 (MD5) / Made available in DSpace on 2017-05-16T20:38:01Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação - Adria M. Oliveira.pdf: 1391584 bytes, checksum: 57b9729c6b3e110a2a4a53cb2c62a068 (MD5) Previous issue date: 2016-12-22 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The practice of plagiarism is a growing and serious problem in academic environment, which interferes on the quality of scientific production, affects the credibility of authoring process and threats the reputation of research institutions. This research focus on the problem of plagiarism detection in source codes developed in the initial programming classes. With the growing number of college students, the manual identification of inconsistency in the evaluations of these classes has become a practice that overcome the teachers/monitors. Despite the wide variety of available tools for plagiarism detection, only few tools are able to effectively identify plagiarism on codes developed by novice programmers, since, in most cases, these codes solve simple questions, and thus generate small solutions. Therefore, this dissertation presents a method for detecting plagiarism in activities in the initial disciplines of programming courses, in order to promote the reliability of results in the teaching-learning process. The proposed method provides satisfactory results in comparison to the methods available in the literature related to the topic. / A prática do plágio é um problema grave e crescente no meio acadêmico, que interfere na qualidade da produção científica, compromete a credibilidade do processo de autoria e ameaça a reputação de instituições de ensino e pesquisa. Esta pesquisa se contextualiza no problema da detecção de plágio entre códigos-fonte desenvolvidos por turmas iniciais de programação. Com o aumento do número de alunos nas instituições, a identificação manual de irregularidades nas avaliações dessas turmas se tornou uma prática que sobrecarrega os professores/monitores. Apesar da ampla quantidade de ferramentas disponíveis para a detecção de plágio, poucas são capazes de identificar, de maneira eficaz, o plágio em códigos desenvolvidos por alunos iniciantes em programação, uma vez que esse códigos solucionam questões simples, e, portanto, geram pequenas soluções. Diante disso, esta dissertação apresenta um método para detectar plágios em atividades das disciplinas iniciais dos cursos de programação, com o intuito de favorecer a confiabilidade dos resultados no processo de ensino-aprendizagem. O método proposto apresenta resultados satisfatórios em comparação aos métodos disponíveis na literatura relacionados ao tema.

Page generated in 0.0521 seconds