• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 52
  • 34
  • 27
  • 23
  • 20
  • 19
  • 15
  • 14
  • 12
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da codisposição de resíduos de fossas e tanques sépticos, com e sem a remoção prévia de gordura, no desempenho de tratamento de esgoto com reatores UASB / Codisposição study of waste and seotic tanks e repair, with and without prior removal of fat in the performance of sewage treatment with UASB reactors

Peixoto, Aline Vieira 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-08T18:01:37Z No. of bitstreams: 1 Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-08T20:24:04Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:33:30Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:22:47Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Made available in DSpace on 2014-12-16T09:22:49Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) Previous issue date: 2013-07-15 / In Brazil, according to a national survey conducted by the Brazilian Institute of Geography and Statistics (IBGE, 2010), 44.8% of the municipalities use simplified domestic waste treatment systems such as septic tanks, rudimentary cesspools and dry pits. Such systems lead to the production of potentially polluting waste which requires suitable co-treatment. Several co-treatment alternatives have been proposed. The present study, which is part of the Program on Basic Sanitation Research (PROSAB), aimed to evaluate the interference caused by septage disposal from cesspools and septic tanks on the performance of the Upflow Anaerobic Sludge Blanket Reactor (UASB) in the city of Itumbiara- Goiás. The study took nine months and was divided into three distinct phases, in which the volumetric flow rate of wastewater from cesspools and septic tanks into the reactor ranged from 0.17% to 0.51%, displaying an intermediate phase of 0.34%.In the third phase, another fat flotation phase was added to the pre-treatment prior to discharge. During the study, we utilized all the waste volume from cesspools and septic tanks produced by the municipality and discharged into the Itumbiara Wastewater Treatment Plant (WWTP), already working at its full capacity. Statistical tests have proved that wastes from cesspool and septic tanks disposed into UASB reactors showed no significant difference in the final effluent quality. It was not evidenced also significant differences in the operation and maintenance of the reactors. The biological sludge from the UASB reactors got stable after being added the wastes (ratio VS/TS between 0.53 and 0.58 average). The receiving reactor’s begs had a worse efficiency but statistical tests showed that the difference was not significant when compared to the control reactors. It was observed in this study, there is no need for the pre-flotation of waste before being released at WWTP with UASB system. Thus the UASB is a viable alternative, but it is necessary to follow a protocol to establish criteria such as the waste application rate, the WWTP site for waste discharge, physical structure and people, as well as to choose for relevant parameters for the waste monitoring before co-treatment. / No Brasil, segundo Pesquisa Nacional de Saneamento Básico do Instituto Brasileiro de Geografia e Estatística (IBGE, 2010), 44,8% dos municípios utilizam sistemas simplificados para tratamento dos esgotos domésticos como: tanques sépticos, fossas rudimentares, fossas secas. Estes sistemas têm como consequência a produção de resíduos com potencial poluidor que necessitam de codisposição adequada. Diferentes alternativas de codisposição têm sido propostas. O presente trabalho, inserido na rede de pesquisa do Programa de Pesquisas em Saneamento Básico (PROSAB), tem como objetivos avaliar as interferências da disposição de resíduos de fossas e tanques sépticos no desempenho do Reator Anaeróbio de Manta de Lodo de fluxo ascendente ou Upflow Anaerobic Sludge Blanket (UASB), na cidade de Itumbiara-Goiás. O estudo teve duração de nove meses e foi dividido em três fases distintas, alterando a taxa de aplicações volumétrica dos resíduos de fossas e tanques sépticos no reator que variou de 0,17% a 0,51%, tendo uma fase intermediária de 0,34%, além de, na terceira fase, acrescentar mais uma etapa de flotação da gordura no tratamento preliminar, antes do lançamento dos resíduos. Durante a pesquisa, foi utilizado todo o volume de resíduos de fossas e tanques sépticos gerados pelo município e dispostos na ETE de Itumbiara que já trabalha com a carga máxima. Testes estatísticos comprovaram que a disposição de resíduos de fossas e tanques sépticos nos reatores UASB não apresentou diferença significativa na qualidade do efluente. Também não foram comprovadas alterações significativas na operação e manutenção dos reatores. O lodo biológico dos reatores UASB apresentou estabilidade após a disposição dos resíduos (relação SV/ST entre 0,53 a 0,58 em média). Os leitos do reator receptor apresentaram pior eficiência, porém testes estatísticos comprovaram que a diferença não foi significativa quando comparado com reatores testemunhos. Foi observou neste estudo, que não há necessidade da flotação prévia dos resíduos antes de serem lançados nas ETEs com sistema UASB. Portanto o UASB é uma alternativa viável, porém é necessário seguir um protocolo com critérios que estabelecerá a taxa de aplicação dos resíduos, o local na ETE onde será lançado o resíduo, estrutura física e de pessoal da ETE e determinar parâmetros de relevância para o monitoramento dos resíduos antes da codisposição.
12

Avaliação clínica longitudinal de dois selantes de fossas e fissuras à base de resina

Kobayashi, Tatiana Yuriko 24 April 2009 (has links)
Os objetivos deste trabalho foram avaliar e comparar por 24 meses, a retencao e as caracteristicas superficiais de dois diferentes materiais seladores, Helioseal Clear e Helioseal F ambos da Ivoclar Vivadente, AG - Schaan, Liechtenstein. Participaram desse estudo, 50 criancas de 6 a 8 anos de idade, com no minimo dois primeiros molares permanentes higidos e historia de carie, num total de 153 dentes divididos em dois grupos: GHC(Helioseal Clear) e GHF (Helioseal F). O selamento foi realizado sob isolamento relativo para todos os grupos, após profilaxia previa com jato de bicarbonato (Profident Dabi-Atlante) e agua e, condicionamento com gel de acido fosforico a 34% por 15 segundos. Apos 6, 12, 18 e 24 meses, a avaliacao clinica foi realizada por dois examinadores calibrados. Avaliou-se a retencao e a incidencia de carie nas 5 areas oclusais: OM, OC, OD, OV e OL (DEERY et al.) e; as caracterisiticas superficiais e a retencao considerando a superficie oclusal com o um todo (criterio modificado de RYGE &SNYDER).Nao houve diferenca estatisticamente significante atraves do teste exato de Fisher na taxa de sucesso (p=0,496 a 1,0) ou para a incidencia de carie (p=0,472 a 1,0) entre as areas avaliadas quando comparado o GHC com GHF durante todo o período estudado. Considerando todas as areas juntas e os grupos separados ou, os dois grupos juntos mas as areas separadas, nao houve diferenca estatisticamente significante, respectivamente, pelo teste de Fisher (p=0,170 a 0,534) e do Qui- Quadrado (p=0,058 a p=0,909), quanto ao sucesso na retencao em nenhum periodo. Quanto a analise da superficie oclusal toda quanto a retencao, esta foi maior e estatisticamente significante para o GHC aos 12m (p=0,0345) e 24m (0,0076). Em relacao as caracteristicas superficiais, o GHC so nao apresentou superioridade quanto a descoloracao superficial, durante o periodo estudado. Para as demais caracteristicas, os resultados do teste de Mann-Whitney foram altamente significantes em diferentes periodos (p= 00000 a 0,0421). A frequencia de bolhas nas superficies seladas, determinada pelo teste do Qui-quadrado, foi maior e significante (p=0,000:12 e 18 meses a p=0,002: 6 e 24 meses) no GHF. Portanto, pode-se concluir que quanto a retencao e caracteristicas superficiais, na superfície oclusal toda, o selante Helioseal Clear apresentou melhor desempenho. / The objectives of this study were evaluated and compared for 24 months, the retention and surface characteristic of two different sealing materials, and Helioseal F Clear Helioseal both of Ivoclar Vivadent, AG - Schaan, Liechtenstein. 50 children from 6 to 8 years of age with at least with two sound first permanent molars and caries of history, total of 153 teeth, were divided into 2 groups: GHC (Helioseal Clear) and GHF (Helioseal F). The sealing was done with ruber dam for all groups, after prophylaxis with air-polishing jet (Profident --Dabi Atlante) and water, and acidetching with 34 % phosphoric acid 34% for 15 seconds. After 6, 12, 18 and 24 months, clinical evaluation was evaluated by two calibrated examiners. To evaluate the retention and the incidence of occlusal caries in 5 areas: OM, OC, OD, and OV OL (DEERY et al.). And, the surface characteristics and retention considering the all occlusal surface (modified criterion RYGE & SNYDER ). There was no statistically significant by Fisher\'s exact test in the rate of success (p = 0,496 to 1.0) or the incidence of caries (p = 0,472 to 1.0) between the areas assessed when compared with the GHC GHF throughout the study period. Considering all areas and groups together or separated, the two groups together but separate areas, there was no statistically significant difference, respectively, by Fisher\'s test (p = 0170 to 0534) and Chi-Square (p = 0,058 to 0,909), about the success in holding in any period. The analysis of the entire occlusal surface on retention, it was higher and statistically significant for the GHC to 12m (p = 0.0345) and 24m (0.0076). In relation to surface characteristics, the GHC showed superiority not only on the superficial discoloration over the period studied. For other characteristics, the results of the Mann-Whitney test were highly significant in different periods (p = 00000 to 0.0421). The frequency of bubbles in the sealed surfaces, as determined by Chi-Square was higher e statistically significant difference (p = 0,000:12 and 18 months p = 0,002: 6 and 24 months) in GHF. Therefore,the retention and surface characteristic in the all occlusal surface, the Helioseal Clear sealant showed better performance
13

Determinação de pressões em fossas de erosão a jusante de dissipadores tipo salto esqui / Pressures determination in scour holes downstream of ski jump dissipators

Buffon, Franco Turco January 2016 (has links)
Nesta dissertação estão apresentados os principais conceitos teóricos envolvidos na ação dos jatos formados em dissipadores tipo salto esqui sobre fossa de erosão pré-escavada, desde o trajeto do jato em sua fase aérea e em sua fase submersa, dando especial ênfase às pressões hidrodinâmicas e sua caraterização junto ao fundo da bacia. Para estudar experimentalmente a ação dos jatos nas bacias de dissipação, utilizou-se de um modelo físico de escala 1:100 construído no Laboratório de Obras Hidráulicas do IPH/UFRGS com ensaios de diferentes vazões e diferentes profundidades de fossas pré-escavadas. Os dados foram extraídos dos ensaios no modelo físico através de vasta instrumentação, utilizando-se comportas, pontas linimétricas, piezômetros, sensores de pressão, imagens e outros equipamentos. Foi realizada uma análise criteriosa dos dados gerados no modelo físico a partir das imagens do jato na sua trajetória aérea e no escoamento do jato em sua fase submersa, comparando os dados do modelo aos resultados obtidos por métodos tradicionais de cálculo. Também foram analisados os dados de pressão gerados durante os ensaios, sendo apresentados os resultados relativos às pressões médias e às pressões dinâmicas. As pressões dinâmicas observadas no modelo físico foram comparadas com as calculadas por meio de metodologia teórica abordada na bibliografia com a finalidade de avaliar a qualidade dessa metodologia para aplicação em projetos de engenharia, onde se observou grandes diferenças de magnitude da pressão quando em colchões rasos, e diferenças de distribuição de pressão ao longo do fundo da bacia de dissipação, principalmente quando em colchões profundos. No sentido de ajustar a metodologia aplicada, foi proposta a variação de parâmetros que regulam a forma do bulbo de pressões e a aplicação de um coeficiente de amortecimento de pressões, sendo que assim foi possível melhorar significativamente a distribuição e a magnitude das pressões calculadas devido à ação dos jatos no fundo da bacia de dissipação. Os resultados se mostram satisfatórios até determinada distância após o pico de pressão provocado pelo jato, sendo que após este ponto os efeitos de ressalto hidráulico prevalecem e devem ser pesquisados em estudos futuros. / In this dissertation are presented the main theorical concepts involved in the action of the jets formed in ski jump spillways on stilling basins type pre-excavated scour hole, from the path of the jet in its air stage and in his submerged phase, with particular emphasis on hydrodynamic pressures and its characterization by the bottom of the basin. To experimentally study the action of the jets in stilling basins, was used a physical model in scale 1:100 built in Hydraulic Works Laboratory of IPH/UFRGS with experiments of different flow rates and different depths of pre-excavated scour hole. The data were extracted from experiments on the physical model through extensive instrumentation, using gates, piezometers, pressure sensors, images and other equipment. A careful analysis of the data generated in the physical model from the jet images in your path through the air was performed and the flow of the jet in its submerged phase, comparing the model data to the results obtained by traditional methods of calculation. The pressure data generated during the tests and presented the results for the mean pressures and dynamic pressures were also analyzed. Dynamic pressures observed in the physical model were compared with those calculated by means of theoretical methods for the purpose of evaluating the quality of this methodology for use in engineering projects, where we observed large differences in magnitude of pressure when in shallow water beds, and diferences in pressure distribution over the stilling basin bottom, especially when in deep water beds. In order to adjust the applied methodology, it was proposed to change parameters governing the shape of the pressure bulb and the application of a pressure damping coefficient, and thus was possible to significantly improved the distribution and magnitude of the calculated pressures due to action of the jets in the stilling basin bottom. The results have been satisfactory up to a certain distance after the peak pressure caused by the jet, and after this point the hydraulic jump effects prevail and should be investigated in future studies.
14

Tecnologias de baixo custo para tratamento de esgoto rural : reator UASB e fossa séptica econômica /

Franceschini, Guilherme. January 2018 (has links)
Orientador: Jorge de Lucas Júnior / Coorientador: Valéria Cristina Rodrigues Sarnighausen / Banca: Marco Antonio Martin Biaggioni / Banca: Gustavo Henrique Ribeiro da Silva / Banca: Adriano Luiz Tonetti / Banca: João Gabriel Thomaz Queluz / Resumo: A falta de tratamento de esgoto sanitário ainda é um dos principais problemas socioambientais da população brasileira, principalmente no contexto dos moradores da zona rural, onde há grande déficit de cobertura. A partir dessa realidade, buscou-se na literatura experiências de sistemas de baixo custo que contemplassem a demanda para o tratamento de esgoto unifamiliar. Identificou-se que as experiências existentes, principalmente no Brasil, são pouco relatadas frente à grande demanda por este tratamento. Neste sentido, a presente pesquisa teve o objetivo de avaliar a eficiência de duas tecnologias de baixo custo para o tratamento de esgoto unifamiliar, a Fossa Séptica Econômica (FSE) e o reator anaeróbio de fluxo ascendente (RAFA ou, em inglês, Upflow Anaerobic Sludge Blanquet, UASB), tendo em vista identificar vantagens e desvantagens de suas aplicações. Foram realizadas análises laboratoriais de amostras do afluente e da saída dos sistemas. Primeiramente os dados foram analisados de forma descritiva, por meio de gráficos e medidas resumo. Para avaliar a eficiência foi realizado o teste t - student e obtidos os intervalos de confiança. Tanto a FSE como o reator UASB evidenciaram-se com desempenho satisfatório quando comparados aos tanques sépticos convencionais, que seguem os parâmetros de dimensionamento da norma brasileira, e com reatores UASB operando com vazões maiores. Para a FSE que tratou todas as águas residuárias de uma residência, com exceção da máquina de lavar rou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The lack of sanitary sewage treatment remain one of the main socio-environmental problems of the Brazilian population, especially in the context of rural dwellers, where there is a huge deficit of coverage. From this reality, we searched in the literature experiences of low cost systems that contemplated the demand for the treatment of single-family sewage. It was identified that the existing experiences, mainly in Brazil, are little reported in face of the great demand for this treatment. In this sense, the present research had the objective of evaluating the efficiency of two low-cost technologies for the treatment of single-family sewage, the Fossa Séptica Economica (FSE) and the Upflow Anaerobic Sludge Blanquet (UASB), in order to identify the advantages and disadvantages of their applications. Laboratory analyzes of tributary and outlet samples were performed. First, the data were analyzed in a descriptive way, by means of graphs and summary measures. To evaluate the efficiency, the student T test was performed and the confidence intervals were obtained. Both the FSE and the UASB reactor showed satisfactory performance when compared to conventional septic tanks, which follow the design parameters of the Brazilian standard, and with UASB reactors operating at higher flow rates. For the ESF that treated all household wastewaters, except for the washing machine, the removal efficiencies for the SST, BOD5 and COD parameters were 77.0 ± 23.7%, 58.4 ± 22.1% and 63.0 ± 22.9%, respectively. The FSE, which treated only black water, had SST, BOD and COD removal efficiencies of 76.2 ± 18.9%, 55.3 ± 19.2% and 60,0 ± 15.6, respectively. The UASB reactor, which also treated only black water, presented efficiencies of removal of SST, BOD5 and COD of 77.8 ± 17.5%, 57.2 ± 19.0 and 50.0 ± 21.7%, respectively. It expected that the present study to contribute to the dissemination of these technologies ... / Doutor
15

Selante de fóssulas e fissuras para o controle de lesões de cárie oclusal: um ensaio clínico controlado randomizado / Pit and fissure sealant to control of occlusal caries lesions: a controlled randomized clinical trial

Jaccottet, Cleusa Marfiza Guimarães 19 December 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-25T13:32:42Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Selante de fóssulas e fissuras para o controle de lesões de cárie oclusal um ensaio clínico controlado randomizado.pdf: 1278912 bytes, checksum: d3e4ca8a1615fb3b7faf3bfa5b9f23e6 (MD5) / Made available in DSpace on 2017-05-25T13:32:42Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Selante de fóssulas e fissuras para o controle de lesões de cárie oclusal um ensaio clínico controlado randomizado.pdf: 1278912 bytes, checksum: d3e4ca8a1615fb3b7faf3bfa5b9f23e6 (MD5) Previous issue date: 2014-12-19 / Sem bolsa / Revisões sistemáticas e metanálises, com base em ensaios clínicos controlados e randomizados (ECR), demonstram que o selante resinoso apresenta um bom desempenho quando aplicado em superfícies oclusais hígidas ou na presença de lesões não cavitadas. Estudos clínicos também demonstram que o selamento de lesões cavitadas com extensão em dentina propicia a paralisação do processo carioso, induzindo ganho mineral. Mesmo diante da importância da utilização de tratamentos minimamente invasivos, poucos ECR têm sido realizados visando estabelecer a longevidade do selante resinoso e seu desempenho clínico quando aplicado em superfícies com presença de lesões que apresentam ruptura da superfície e extensão em dentina. O presente ECR avaliou a longevidade do selante resinoso de fóssulas e fissuras em lesões com microcavidades de até 0,5 mm de diâmetro, com desmineralização na dentina em superfícies oclusais de molares permanentes em pacientes jovens de 10 a 25 anos, e comparou ao tratamento restaurador convencional com resina composta por um período de 22 meses. A avaliação dos materiais foi realizada com base nos critérios da Federação Dentária Internacional-FDI, sendo utilizadas para a avaliação dos resultados a análise bivariada e a curva de sobrevivência dos materiais (p < 0,05). Cinquenta e um pacientes, sessenta e um dentes receberam a intervenção, destes, quarenta pacientes totalizando cinquenta e um dentes foram avaliados, sendo que 25 receberam selante (49%) e 26 restaurações com resina composta (51% - grupo controle). Conforme resultados, o grupo dos selantes falhou mais que o das restaurações de resina composta. Dos 25 dentes selados, oito (32%) apresentaram fratura ou perda total ou parcial do material, enquanto que dos 26 dentes restaurados com resina composta, nenhum apresentou falha (P= 0,003). A taxa de falha anual para o selante foi de 18,9%, dos oito dentes em que constaram falhas, dois apresentaram fratura de esmalte e presença de cavidade de cárie dentária. O selante também apresentou menor probabilidade de sobrevivência em pacientes com presença de lesão ativa após o período de acompanhamento (p=0,005), com desempenho inferior ao da resina composta em relação à adaptação marginal (p=0,046). Diante dos resultados encontrados neste estudo, podemos concluir que o selante resinoso teve desempenho inferior em comparação com restaurações de resina composta para o tratamento de lesões de cárie com extensão em dentina. / Systematic reviews and meta-analysis based on controlled and randomized clinical trials (RCT) have been showed that resin sealant has a good clinical performance when applied in sound surfaces or in non-cavitated lesions. Others clinical studies have shown that sealing of caries lesions, including those that are localized in the middle third of dentin, can reduce the bacterial growth in the infected dentin leading to stop the carious process and inducing mineral gain. Few RCT have been conducted to establish the resin sealant longevity and its clinical performance when applied to caries lesions which present breaks into enamel and dentin surface. This RCT evaluated the resin sealant longevity applied in occlusal surface of permanent molar that present caries lesions with microcavities (up to 0.5mm diameter) and compared to conventional restorative treatment (composite resin) from young patients aged 10 to 25 years for a period of up to 22 months. Dental materials were evaluation according FDI criteria. Bivariate analysis and survival curves were used to evaluate the results (p <0.05). Fifty one patients and 61 teeth received the allocates intervention. From these, forty patients (51 teeth) were evaluated. Of those, 25 teeth received sealant (49%), and 26 resin composite treatment (56%-control group). The sealant group showed more failures than composite resin restorations. Eight of 25 teeth with sealant (32%) presented fracture or total or partial material loss. None tooth with composite resin restoration showed failure (P= 0.003). Sealant annual failure rate was 18.9%. Sealant also presented a lower survival probability in patients with active caries lesion at evaluation time (P = 0.005), and showed inferior performance compared to resin composite when marginal adaptation was evaluated (p = 0.046). Therefore, the resin sealant showed inferior performance when compared to composite resin restoration for caries lesion presenting microcavities with dentin extension.
16

Quantificação de unidades formadoras de colônias de Streptococcus mutans em restaurações oclusais e selantes em dentes mediante a técnica da moldeira. Estudo clinico cego / Counting colony forming unit of Streptococcus mutans on occlusal restorations and sealants of teeth by tray technique. Blind clinical study

Vildósola Grez, Patricio Agustin [UNESP] January 2015 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2015. Added 1 bitstream(s) on 2017-03-14T14:42:48Z : No. of bitstreams: 1 000874703_20170916.pdf: 127430 bytes, checksum: 6c7f9d658a64027218edeedd8022d757 (MD5) Bitstreams deleted on 2017-09-22T12:16:27Z: 000874703_20170916.pdf,. Added 1 bitstream(s) on 2017-09-22T12:17:18Z : No. of bitstreams: 1 000874703.pdf: 1294999 bytes, checksum: 1c6b907cb99545ab91c73127d7a207c0 (MD5) / As restaurações e selantes podem sofrer cárie como qualquer material, devido à possibilidade das bactérias de aderir-se a suas superfícies. Objetivo principal foi colher e quantificar (contagem) das unidades formadoras de colônias de S. mutans de forma direta pela técnica da moldeira (TR) em restaurações de resina composta (RC), amálgama (AM) e em selantes de fóssulas e fissura. Material e método: Recrutaram-se 40 pacientes para o estudo de avaliação da TR, 65 para a comparação das restaurações de AM e RC e 38 para o selante. Critérios inclusão: pacientes 18-50 anos, mínimo 28 dentes na boca, pelo menos uma restauração oclusal de RC e de AM avaliadas alfa pelo critério Ryge (Kappa 0,8), e um dente com indicação de selante. Numa primeira parte, no mesmo paciente foram realizadas amostragem de saliva, impressões de RC ou AM com a TR e a técnica toothpick (TT). Na segunda e terceira etapa num mesmo paciente foram realizadas impressões de RC ou AM com a TR e no caso de selante num mesmo dente foi realizado antes e após da aplicação. TR foi feita numa moldeira de fluoreto com ágar tripticase, extrato levedura, L-cisteína, sacarose e bacitracina (TYCSB) preparada previamente. As amostras foram incubadas a 37ºC durante 48 horas, após uma contagem de unidades formadoras de colônias (UFC) foi realizado por um operador calibrado. Os resultados foram analisados com um nível de confiança do 95%. Resultados: TR foi capaz de colher e isolar S. mutans, e ter uma correlação positiva significativa (r = 0,95) com TT. Não houve correlação significativa entre TR e grupo saliva (r = 0,47). RC tive diferença estatística significativa com maior número de UFC de S. mutans do que AM (p< 0,05). A mediana de UFC/cm2 foi de 111,00 para antes aplicação de selante e 22,00 após aplicação(p< 0,05). Conclusões : TR pode colher UFC de S. mutans desde as superfícies ... (Resumo completo, clicar acesso eletrônico abaixo) / The restorations suffer secondary decay as anything material, because of the possibility of bacteria from adhering to theirs surfaces. Therefore the aim of the study is quantified (count) the colonies forming units (CFU) of S. mutans by tray technique in resin composite (RC), amalgam (AM) restorations and sealants of pits and fissures. Material and Method: 40 patients were selected to assess the tray technique, 65 patients to compare AM restorations and RC and 38 patients for sealant. Inclusion criteria: Patients 18 - 50 years old, with 28 teeth, at least one occlusal restorations with RC and AM, evaluated alfa Ryge criteria (Kappa 0.8), and at least with one teeth with indication of occlusal sealant. First study, int the same patient was taken saliva samples, for RC or AM took the impression by TR and toothpick technique (TT). The second and third parts in the same patient were taken RC and AM impression by TR and the sealant of study in the same tooth was performed before and after the sealant application. This method was performed with a fluoride tray previously loaded with a solid tripticase yeast extract cysteine sucrose and bacitracin agar. The samples were incubated at 37°C for 48 hours, after the colonies forming units (CFU) were quantified by a calibrated operator (Kappa 0.8). The results were analyzed with a confidence level of 95%. Results: TR was able to recover and isolated S. mutans, and had a positive correlation (r= 0.95) with TT. There was no significant correlation between TR and saliva (r= 0.47). RC restorations, there was statistical significant difference, with higher number of CFU of S. mutans than AM (p< 0.05). The median CFU/cm2 was 111,00 before the sealant application and 22,00 after sealant application (p< 0.05). Conclusion: The TR was be able recover CFU of S. mutans from occlusal restorations with positive correlation and significant with TT...(Complete abstract electronic access below)
17

Métodos preventivos em primeiro molar permanente de crianças com experiência de cárie dentária : estudo clínico comparativo /

Oliveira, Daniela Cristina de. January 2015 (has links)
Orientador: Robson Frederico Cunha / Coorientador: / Banca: Max Douglas Faria / Banca: Denise Pedrine / Banca: Célio Percinotto / Banca: Edo Hirata / Resumo: É na infância que os dentes, em geral, são mais vulneráveis, estando mais susceptíveis a contrair cárie dentária, especialmente no período de irrupção, momento em que o elemento dental se encontra em infra oclusão, o que favorece o acúmulo de placa e dificulta sua adequada higienização. Soma-se ainda a pouca habilidade da criança em executar as manobras de uma adequada escovação dentária. O primeiro molar permanente em irrupção, além destes fatores de susceptibilidade citados, é por excelência um nicho de colonização de microrganismo pela sua anatomia oclusal, fato que torna este período de alto risco para o surgimento de novas lesões de cárie dentária. Portanto, partindo da premissa que molares permanente em fase de irrupção, de criança com experiência de cárie dentária, são mais susceptíveis a adquirir a doença, o objetivo desse trabalho foi comparar três métodos preventivos da ocorrência de lesão cariosa neste dente. Participaram do estudo 242 crianças (968 molares), de ambos os gêneros, na faixa etária de 6 a 8 anos, com experiência de cárie dentária, apresentando os quatros primeiros molares permanentes hígidos em fase de irrupção. As crianças foram divididas aleatoriamente em três grupos: grupo com 81 crianças, cujo os 324 molares receberam aplicação única de selante de fossas e fissuras à base de ionômero de vidro (SIV), grupo com 83 crianças (332 molares), com aplicação de verniz fluoretado (VF) em 3 sessões (0, 6 e 12 meses) e grupo com 78 crianças, 312 molares que receberam profilaxia profissional (PP) em 6 sessões (0, 3, 6, 9, 12 e 15 meses). A avaliação clínica pós-operatória foi realizada após 6, 12 e 18 meses, para os pacientes... / Abstract: It is in childhood that the teeth in general, are more vulnerable, are more susceptible to getting tooth decay, especially in the outbreak period, hampering their proper hygiene. Also, it is added to the little child's ability to perform the maneuvers of proper tooth brushing. The first permanent molar eruption, in addition to cited susceptibility factors, is par excellence a microorganism colonization niche because of its occlusal anatomy, a fact that makes of this period highly risky for the emergence of new lesions of dental caries. Therefore, based on the premise that children with caries experience in the permanent molar eruption phase are more likely to acquire the disease, the goal of this study was to compare three preventive methods of occurrence of carious lesions in the tooth. The study included 242 children (968 molars), of both genders, aged 6-8 years, with caries experience, with the four first permanent molars at the erupting phase. The children were randomly divided into three groups: a group of 81 children, whose 324 molar received a single application of pit and fissure sealant made on the basis of glass ionomer (GIS), a group of 83 children (332 molars), with coating application of fluoride varnish (FV) in 3 sessions (0, 6 and 12 months) and a group of 78 children (312 molars) who received professional prophylaxis (PP) in 6 sessions (0, 3, 6, 9, 12 and 15 months). Patients were clinically evaluated after 6, 12 and 18 months, patients... / Doutor
18

Desempenho de sistema alagado construído para tratamento de esgoto doméstico / Performance of constructed wetland system for the treatment of domestic sewage

Brasil, Mozart da Silva 27 July 2005 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-03-09T10:13:35Z No. of bitstreams: 1 texto completo.pdf: 1881185 bytes, checksum: 0e63427a670b7f41983d11a0ddc7d4a4 (MD5) / Made available in DSpace on 2017-03-09T10:13:35Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1881185 bytes, checksum: 0e63427a670b7f41983d11a0ddc7d4a4 (MD5) Previous issue date: 2005-07-27 / Este trabalho teve por objetivo obter os parâmetros da equação de cinética de remoção de carga orgânica e avaliar o desempenho de quatro sistemas alagados construídos (SACs) de 24,0 x 1,0 x 0,3 m, com fluxo subsuperficial no tratamento de efluente doméstico proveniente de tanque séptico. O sistema foi preenchido com brita # 0, como meio-suporte, onde a taboa (Typha sp) foi cultivada, empregando-se dois tempos de residência hidráulica – t (1,9 e 3,8 dias) e diferentes taxas médias de carga orgânica volumétrica (116, 164 e 210 g m 3 d -1 ). Para tanto, foram quantificadas as seguintes variáveis: demanda química de oxigênio (DQO), sólidos suspensos totais (SST), turbidez, nitrogênio total (N-Total), fósforo total (P-Total), potássio, sódio, condutividade elétrica, potencial redox (Eh) e pH. Os parâmetros K V e n do modelo cinético de remoção de carga orgânica foram obtidos por regressão não-linear. Com exceção do sódio, cuja concentração efluente não foi reduzida, o sistema de tratamento apresentou eficiência na remoção das variáveis avaliadas, pois, foram obtidas médias de 87%, 81%, 91%, 88%, 33%, 35% e 35% para DQO, DQO solúvel, SST, turbidez, N- Total, P-Total e potássio, respectivamente, nos SACs 1, 2 e 4 e de 90%, 85%, 91%, 86%, 57%, 48% e 52%, respectivamente, no SAC 3. As taxas de carga orgânica não tiveram influência negativa na remoção de poluentes, com exceção da eficiência de remoção de fósforo que decresceu com o aumento das taxas de aporte deste nutriente em dos dois SACs avaliados. O t de 3,8 dias foi mais efetivo na remoção dos poluentes do que o t de 1,9 dias, com exceção de SST que não variou durante a remoção, embora o t de 1,9 dias tenha sido suficiente para produzir um efluente que atendesse aos padrões de lançamento em corpos hídricos receptores, em conformidade com a legislação ambiental do Estado de Minas Gerais. O modelo de remoção de 1a ordem de carga orgânica não se ajustou bem aos dados, enquanto o modelo de remoção modificado e proposto neste trabalho (Ce/Ca = exp(-K t n ) teve bom ajuste e descreveu, adequadamente, a cinética de remoção de carga orgânica no sistema avaliado. / This study was carried out to obtain the parameters of the kinetics equation of the organic load removal and to evaluate the performance of four constructed wetland systems (SACs) measuring 24.0 x 1.0 x 0.3 m with subsurface flow in treatment of the domestic effluent proceeding from septic tank.. The system was infilled with gravel # 0 as a support medium where the cattail plant (Thypha sp) was cropped, by operating under two times of hydraulic residence - t (1.9 and 3.8 days) and different average rates of volumetric organic loads (116, 164 and 210 g m 3 d -1 . So, the following variables were quantified: chemical oxygen demand (DQO), total suspended solids (SST), turbidity, total nitrogen (total-N), total phosphorus (total-P), potassium, sodium, electric conductivity, redox potential (Eh), and pH. The parameters K V and n of the kinetic model of the organic load removal were obtained by nonlinear regression. Except for sodium, from which the effluent concentration was not reduced, the treatment system showed to be efficient in removing the evaluated variables, since averages of 87%, 81%, 91%, 88%, 33%, 35% and 35% were respectively obtained for DQO, soluble DQO, SST, turbidity, total-N, total-P, and potassium in SACs 1, 2 and 4, as well as 90%, 85%, 91%, 86%, 57%, 48% and 52%, respectively, in SAC 3. The organic load rates had no negative influence negatively on the removal of pollutants, except for the efficiency in the removal of phosphorus that was decreased with the increased supply rates of this nutrient in two of the evaluated SACs. The 3.8-day time (t) was more effective than the 1.9-day time in removing the pollutants, except for SST that did not varied over their removal, although the 1.9-day time was enough to produce such an effluent that would satisfy to the discharge patterns in the water-receiving bodies according to Minas Gerais State’s environmental legislation. The first-ordered removal model of the organic load did not satisfactorily adjusted to the observed data, whereas the modified removal model and proposed in this work (Ce/Ca = exp(-K t n ) showed a good adjustment, besides describing appropriately the kinetics of the organic load removal in the evaluated system. / Tese importada do Alexandria
19

Avaliação in vitro do potencial anticárie de selantes resinosos e ionoméricos contendo digluconato de clorexidina / Evaluation in vitro of the anticaria potential of resinal and ionomeric selantes containing chlorexidine digluconate

Vieira, Pedro Henrique Acioly Guedes Peixoto 13 December 2016 (has links)
VIEIRA, P. H. A. G. P. Avaliação in vitro do potencial anticárie de selantes resinosos e ionoméricos contendo digluconato de clorexidina. 2016. 76 f. Dissertação (Mestrado em Microbiologia Médica) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-01-20T13:18:07Z No. of bitstreams: 1 2016_dis_phagpvieira.pdf: 1404772 bytes, checksum: ce74f306b269b6469e5e0715ad17f855 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-01-20T13:18:15Z (GMT) No. of bitstreams: 1 2016_dis_phagpvieira.pdf: 1404772 bytes, checksum: ce74f306b269b6469e5e0715ad17f855 (MD5) / Made available in DSpace on 2017-01-20T13:18:15Z (GMT). No. of bitstreams: 1 2016_dis_phagpvieira.pdf: 1404772 bytes, checksum: ce74f306b269b6469e5e0715ad17f855 (MD5) Previous issue date: 2016-12-13 / Sealants are materials applied to scars and fissures to prevent onset the onset of the caries process or interrupt its progression. Chlorhexidine (CLX) is a broad spectrum antimicrobial agent whose incorporation has been tested in various dental materials. The objective of this study was to evaluate the in vitro effect of the incorporation of chlorhexidine digluconate (DC) at 0.5% on the properties of a resinous sealant (SR) and a chemically activated ionomeric sealant (SI). The effect of the incorporation of CLX on the roughness of the materials was also evaluated. (Bioseal®-control group), SRDC (Bioseal® + 0.5% DC), SI (Riva Protect®) and SIDC (Riva Protect®) + 0.5% of DC). For an enamel caries induction, a microbiological model of S. mutans biofilm formation was used for five days, three blocks of each group for each experimental triplicate. The antimicrobial effect was evaluated by counting UFCs (colony forming units), dry weight analysis and confocal microscopy. To evaluate the demineralization, the blocks were analyzed by longitudinal microhardness of the enamel at 50 μm and 100 μm of the restoration margin. In addition, for each experimental group, test specimens from all groups were analyzed for their surface roughness pattern. Data were analyzed using ANOVA (two factors), with significance level of 5%. SR presented fewer CFUs when compared to SI (p = 0.004). Regarding dry weight, SR was lower than SI (p = 0.006). In the analysis of hardness at 50 μm, lower demineralization was observed for groups with ionomer when compared to those with resin (p <0.001), as well as between groups with CLX when compared to groups without CLX (p = 0.026). In the distance of 100 μm, the groups with ionomer showed a lower demineralization when compared to those with resin (p <0.001). The roughness in SI was superior to SR, both before (p = 0.032) and after exposure to cariogenic biofilm (p <0.001). In general, confocal laser microscopy (MCLS) data provided information consistent with the efficiency of CLX incorporation favoring the antimicrobial activity of resinous sealants when compared to ionomeric sealants. The ionomeric materials have a higher anticaryeffect, however the incorporation of DC seems to be more effective and necessary when using resinous sealants. / Os selantes são materiais adesivos aplicados em cicatrículas e fissuras para prevenir in loco o início do processo de cárie ou interromper sua progressão. A clorexidina (CLX) é um agente antimicrobiano de amplo espectro, cuja incorporação tem sido testada em diversos materiais odontológicos. O objetivo deste estudo foi avaliar o efeito in vitro da incorporação de digluconato de clorexidina (DC) a 0,5% sobre as propriedades anticárie de um selante resinoso (SR) e um selante ionomérico quimicamente ativado (SI). O efeito da incorporação de CLX na rugosidade dos materiais também foi avaliado. Blocos de esmalte dentário bovino (8x8x4 mm) com preparos cavitários foram restaurados utilizando o selante, de acordo com os grupos: SR (Bioseal®-grupo controle), SRDC (Bioseal® + 0,5% de DC), SI (Riva Protect ®) e SIDC (Riva Protect ® + 0,5% de DC). Para a indução de cárie em esmalte, utilizou-se um modelo microbiológico de formação de biofilme de S. mutans durante cinco dias, sendo três blocos de cada grupo para cada triplicata experimental. O efeito antimicrobiano foi avaliado através da contagem de UFCs (unidades formadoras de colônia), análise do peso seco e microscopia confocal. Para avaliar a desmineralização, os blocos foram analisados por microdureza longitudinal do esmalte em 50 μm e 100 μm da margem de restauração. Além disso, para cada grupo experimental, corpos de prova de todos os grupos foram analisados quanto ao seu padrão de rugosidade de superfície. Os dados foram analisados utilizando ANOVA (dois fatores), com nível de significância de 5%. SR apresentou menos UFCs quando comparado a SI (p=0,004). Em relação ao peso seco, SR foi menor que o SI (p=0,006). Na análise de dureza à 50 µm, menor desmineralização foi observada para os grupos com ionômero quando comparados àqueles com resina (p<0,001), assim como entre os grupos com CLX quando comparados aos grupos sem CLX (p=0,026). Na distância de 100 µm, os grupos com ionômero apresentaram uma menor desmineralização quando comparados àqueles com resina (p<0,001). A rugosidade em SI foi superior a SR, tanto antes (p=0,032) quanto após a exposição ao biofilme cariogênico (p<0,001). De forma geral, os dados de microscopia confocal a laser (MCLS) forneceram informações condizentes com a eficácia da incorporação de CLX favorecendo a atividade antimicrobiana dos selantes resinosos quando comparada ao selantes ionoméricos. Os materiais ionoméricos têm um maior efeito anticárie, no entanto a incorporação de DC parece ser mais eficaz e necessária quando da utilização de selantes resinosos.
20

Determinação de pressões em fossas de erosão a jusante de dissipadores tipo salto esqui / Pressures determination in scour holes downstream of ski jump dissipators

Buffon, Franco Turco January 2016 (has links)
Nesta dissertação estão apresentados os principais conceitos teóricos envolvidos na ação dos jatos formados em dissipadores tipo salto esqui sobre fossa de erosão pré-escavada, desde o trajeto do jato em sua fase aérea e em sua fase submersa, dando especial ênfase às pressões hidrodinâmicas e sua caraterização junto ao fundo da bacia. Para estudar experimentalmente a ação dos jatos nas bacias de dissipação, utilizou-se de um modelo físico de escala 1:100 construído no Laboratório de Obras Hidráulicas do IPH/UFRGS com ensaios de diferentes vazões e diferentes profundidades de fossas pré-escavadas. Os dados foram extraídos dos ensaios no modelo físico através de vasta instrumentação, utilizando-se comportas, pontas linimétricas, piezômetros, sensores de pressão, imagens e outros equipamentos. Foi realizada uma análise criteriosa dos dados gerados no modelo físico a partir das imagens do jato na sua trajetória aérea e no escoamento do jato em sua fase submersa, comparando os dados do modelo aos resultados obtidos por métodos tradicionais de cálculo. Também foram analisados os dados de pressão gerados durante os ensaios, sendo apresentados os resultados relativos às pressões médias e às pressões dinâmicas. As pressões dinâmicas observadas no modelo físico foram comparadas com as calculadas por meio de metodologia teórica abordada na bibliografia com a finalidade de avaliar a qualidade dessa metodologia para aplicação em projetos de engenharia, onde se observou grandes diferenças de magnitude da pressão quando em colchões rasos, e diferenças de distribuição de pressão ao longo do fundo da bacia de dissipação, principalmente quando em colchões profundos. No sentido de ajustar a metodologia aplicada, foi proposta a variação de parâmetros que regulam a forma do bulbo de pressões e a aplicação de um coeficiente de amortecimento de pressões, sendo que assim foi possível melhorar significativamente a distribuição e a magnitude das pressões calculadas devido à ação dos jatos no fundo da bacia de dissipação. Os resultados se mostram satisfatórios até determinada distância após o pico de pressão provocado pelo jato, sendo que após este ponto os efeitos de ressalto hidráulico prevalecem e devem ser pesquisados em estudos futuros. / In this dissertation are presented the main theorical concepts involved in the action of the jets formed in ski jump spillways on stilling basins type pre-excavated scour hole, from the path of the jet in its air stage and in his submerged phase, with particular emphasis on hydrodynamic pressures and its characterization by the bottom of the basin. To experimentally study the action of the jets in stilling basins, was used a physical model in scale 1:100 built in Hydraulic Works Laboratory of IPH/UFRGS with experiments of different flow rates and different depths of pre-excavated scour hole. The data were extracted from experiments on the physical model through extensive instrumentation, using gates, piezometers, pressure sensors, images and other equipment. A careful analysis of the data generated in the physical model from the jet images in your path through the air was performed and the flow of the jet in its submerged phase, comparing the model data to the results obtained by traditional methods of calculation. The pressure data generated during the tests and presented the results for the mean pressures and dynamic pressures were also analyzed. Dynamic pressures observed in the physical model were compared with those calculated by means of theoretical methods for the purpose of evaluating the quality of this methodology for use in engineering projects, where we observed large differences in magnitude of pressure when in shallow water beds, and diferences in pressure distribution over the stilling basin bottom, especially when in deep water beds. In order to adjust the applied methodology, it was proposed to change parameters governing the shape of the pressure bulb and the application of a pressure damping coefficient, and thus was possible to significantly improved the distribution and magnitude of the calculated pressures due to action of the jets in the stilling basin bottom. The results have been satisfactory up to a certain distance after the peak pressure caused by the jet, and after this point the hydraulic jump effects prevail and should be investigated in future studies.

Page generated in 0.0381 seconds