• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores

Carlo, Hugo Lemes [UNESP] 19 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-10-19Bitstream added on 2014-06-13T18:51:43Z : No. of bitstreams: 1 carlo_hl_me_arafo.pdf: 663650 bytes, checksum: 1703d1cf829a007bfb4eb9e624207ea1 (MD5) / O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de...
2

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores /

Carlo, Hugo Lemes. January 2004 (has links)
Orientador: Maria Salete Machado Cândido / Banca: José Roberto Cury Saad / Banca: Jesuania Maria Guardiero Azevedo Pfeifer / Abstract: The aim of this work was to evaluate the linear polymerization shrinkage and the degree of conversion of two commercial composite resins, with similar compositions, being one of use in anterior and posterior teeth (Filtek Z250) and other for use in posterior teeth (Filtek P60). The effect of different light sources was also evaluated in that process, and were used for that an halogen light curing (Degulux - Degussa) and a LED light curing of high intensity (Ultrablue IS - DMC). In that way, the materials and light sources were divided in four groups: Group 1 - Filtek Z250 resin cured with the halogen light curing (QHT); Group 2 - Filtek Z250 cured with LED light curing (LED); Group 3 - Filtek P60 resin cured with the halogen light curing (QHT); Group 4 - Filtek P60 cured with the LED light curing (LED). The polymerization shrinkage was measured with the insert of the materials in a plastic tube and the values of the alterations accomplished by an electronic instrument of linear measure with sensibility for 1æm. The conversion degree was obtained through Fourier Transform Infrared Spectroscopy (FTIR), where the picks were analyzed inside of the bands of interest in the values of 1.646 cm-1 and 1.731 cm-1, corresponding to the connections C=C aliphatic and C=O respectively. The results were submitted to the statistical analysis of Variance and test of Tukey (a = 0,05), which allowed to end that: the polymerization shrinkage of different materials (Filtek Z250 and Filtek P60) presented different behavior with the use of the same light source (LED); the degree of conversion of the materials came similar in relation to materials and light sources; the LED light curing (Ultrablue IS) presented results of polymerization shrinkage and degree of conversion that allow it to be used as an alternative to QHT light curing units. / Resumo: O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
3

Microdureza superficial do cimento resinoso de ativado por duas diferentes fontes de luz com interposição de cerômero e porcelana

Alencar Júnior, Emmanuel Arraes de [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T18:42:03Z : No. of bitstreams: 1 alencarjunior_ea_dr_arafo.pdf: 544864 bytes, checksum: 9e132bf130badf4c90a40a1d5fbc0aee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nessa pesquisa utilizou-se de três unidades fotoativardoras na polimerização de uma marca comercial de cimento resinoso de dupla ativação, com a interposição de uma lâmina de cerômero e de porcelana, para avaliar a microdureza superficial do cimento resinoso, considerando sua superfície do topo e da base Os corpos-de-prova foram confeccionados utilizando-se matrizes metálicas com 2mm de espessura e 16mm de diâmetro, com o orifício central medindo 8mm de diâmetro (figura 4), coincidindo com o diâmetro da ponta dos aparelhos de luz. Como espaçadores foram utilizados anéis metálicos com 2mm e 4mm de altura confeccionados de cerâmica e cerômero, na tentativa de se reproduzir as espessuras médias das restaurações indiretas realizadas clinicamente. Foram realizados quatro corpos-de-prova para cada grupo, com os três aparelhos fotoativadores e para cada grupo do material intermediário. A inserção da resina no orifício central da matriz foi realizada em uma única porção, utilizando-se de uma seringa Centrix. Após a inserção do cimento, obteve-se um pequeno excesso do material. Sobre o cimento a foi colocada uma tira de poliéster e posicionado peso de um quilo para a homogeneização e planificação da superfície. Após a remoção do peso, foi executada a ativação do cimento resinoso com a ponta dos aparelhos de luz utilizados no experimento, posicionado diretamente sobre as pastilhas de cerâmica e cerômero. Os corpos-de-prova foram removidos da matriz metálica, acondicionados em recipientes à prova de luz e mantidos a temperatura de 37o C durante 24 horas. As superfícies do topo e da base do corpo-de-prova foram polidas com lixas d'água em graus descendentes (800, 320 e 600 norton) de abrasividade e submetidas ao teste de microdureza. Para a determinação da microdureza, foi utilizado o aparelho Microdurômetro Digital MHT-110 MICROHARDNESS TESTER, Anton... . / The aim of this study was to evaluated the efficiency of three different units of light curing in activating a commercial trend of resin cement. The body-of-test had been confectioned using first metallic with 2mm of thickness and 16mm of diameter, with the central orifice measuring 8mm of diameter (figure 4), coinciding with the diameter of the tip of the light devices. As spacers metallic rings with 2mm and 4mm of height confectioned of ceramics had been used and cerômero, in the attempt of if clinically reproducing the average thicknesses of the carried through indirect restorations. They had been carried through four body-of-test for each group, with the three devices photo curing and for each group of the intermediate material. The insertion of the resin in the central orifice of the matrix was carried through in an only portion, using itself of a Centrix syringe. After the insertion of the cement, got a small excess of the material. On the cement a polyester strap was placed it and located weight of one kilo for the homogenization and planning of the surface. After the removal of the weight, was executed the activation of the resin cement with the tip of the devices of light used in the experiment, located directly on the tablets of ceramics and ceromer. The test bodies had been gotten thus the body-of-test had been removed of the metallic matrix, conditioned in containers to the test of light and kept the temperature of 37o C during 24 hours. The surfaces of the top and the base of the body-of-test had been polishing with sandpapers in degrees descending (800, 320 and 600 norton) of abrasiveness and submitted to the micro hardness test. For the determination of the micro hardness, the device Digital Micro hardness tester MHT-110 MICROHARDNESS TESTER, Anton Paar-Paar Physica, Graz was used, Austria, of the Institute of Chemistry of Araraquara (UNESP) with load of 50N during 30 seconds... (Complete abstract, click electronic address below)
4

Uso da terapia fotodinâmica para a inativação de Aggregatibacter actinomycetemcomitans em meio planctônico e em biofilme / The use of Photodynamic therapy to inactivate Aggregatibacter actinomycetemcomitans in planktonic medium and biofilm

Goulart, Rosangela de Carvalho 28 January 2010 (has links)
A proposta deste trabalho foi de aplicar a Terapia Fotodinâmica (TFD) para avaliar a inativação da bactéria Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans), um patógeno que está associado à endocardite bacteriana, abscessos cerebrais e subcutâneos e principalmente à doença periodontal, que é caracterizada pela inflamação dos tecidos de suporte dos dentes, e consequentemente a perda de dentes. O surgimento de resistência bacteriana a diversas classes de antibióticos vem sendo um problema sério que surge como efeito do uso indiscriminado destes fármacos e até mesmo por fatores adaptativos dos microrganismos. Devido a este fator, várias investigações vêm surgindo com referências satisfatórias no que diz respeito ao emprego da TFD como medida terapêutica. O efeito da TFD foi verificado sobre a cultura da bactéria A. actinomycetemcomitans em meio planctônico e em biofilme. Foi utilizado como agentes fotossensibilizadores Rose bengal, Azul de metileno e Eritrosina, que em baixas concentrações não causam toxicidade para células de fibroblastos e células humanas. Como fonte de luz foi utilizado o fotopolimerizador de resina odontológica, que é de fácil acesso, baixo custo e apresenta uma faixa de emissão de luz de 300 a 800 nm. Rose Bengal até 1 µM não afetou as células de fibroblastos, mas essa mesma concentração sem usar a TFD reduziu a viabilidade de A. actinomycetemcomitans em 41,2%, porém as células de A. actinomycetemcomitans quando cultivadas em biofilme não foram afetadas quando se usou apenas o corante (0,5 e 1,0 µM) ou apenas a luz. Quando se aplicou a TFD Rose Bengal foi o segundo corante (entre os três estudados), que causou uma maior redução da viabilidade celular de A. actinomycetemcomitans cultivadas em meio planctônico 54,4% e o terceiro em reduzir a viabilidade quando cultivadas em biofilme com 45% de redução. Azul de Metileno nas concentrações de 0,5 e 1,0 µM reduziu a viabilidade de A. actinomycetemcomitans em meio planctônico 16 e 24% respectivamente, já sobre o biofilme essa concentração de corante não promoveu redução da viabilidade bacteriana. Com a TFD observou-se uma redução de 50% da viabilidade das células de A. actinomycetemcomitans em meio planctônico e 53,3% em biofilme. Dos três corantes utilizados Eritrosina foi o corante que per se apresentou menor redução da viabilidade 5 e 14%, indicando ter baixa toxicidade, no escuro, e não afetou as células do biofilme de A. actinomycetemcomitan. Porém com a TFD, esse corante promoveu uma maior redução da viabilidade das células bacterianas de A. actinomycetemcomitans cultivadas em meio planctônico e em biofilme 75% e 67,2% respectivamente. Desta forma, a Eritrosina foi o corante mais eficiente em diminuir a viabilidade de A. actinomycetemcomitans nas condições estudadas. Esses resultados indicam que a TFD reduz as células viáveis de A. actinomycetemcomitans cultivadas em meio planctônico e em biofilme, indicando que essa terapia poderá ser uma opção efetiva para o tratamento clinico da doença periodontal, com a vantagem de não apresentar efeitos colaterais como a terapia medicamentosa, nem desenvolver a resistência bacteriana que vem sendo um grande problema do tratamento com antibióticos. / The objective of this work was to apply the photodynamic therapy (TFD) to evaluate the inactivation of the Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans) bacteria, a pathogen that is associated to bacterial endocarditis, subcutaneous and cerebral abscesses and mainly to periodontal disease, which is characterized by inflammation of teeth support tissue and as a consequence, teeth loss. The occurrence of bacterial resistance to many classes of antibiotics has been a serious problem that results from the indiscriminate use of these drugs and also by the adaptation factors of these microorganisms. Due to this, many investigations are being done with satisfactory references regarding the use of TFD as therapeutic step. The TFD effect on A. actinomycetemcomitans bacteria culture in planktonic medium and biofilm was verified. Rose Bengal, methylene Blue and Erythrosyn were used as photosensitizing agents which, in low concentrations are not toxic to fibroblast cells and human cells. The odontological resin photopolymerizer was used as a light source since it is easy accessible, low cost and has a light emission range between 300 and 800nm. Rose Bengal up to 1 µM did not affect the fibroblast cells, but this same concentration without the use of TFD has reduced viability of A. actinomycetemcomitans in 41.2%, but the cells when cultivated in biofilm were not affected when only dye (0.5 and 1.0 µM) or only light were used. When TFD was applied, Rose Bengal was the second dye (among the three studied) to cause the highest reduction of cell viability of A. actinomycetemcomitans cultivated in 54.4% planktonic medium and the third in reducing the viability when cultivated in biofilm, with 45% reduction. Methylene Blue in 0.5 and 1.0 µM concentrations has reduced the viability of A. actinomycetemcomitans in planktonic medium in 16% and 24%, respectively. In biofilm, this dye concentration has not fostered bacterial reduction. With TFD, a 50% reduction of A. actinomycetemcomitans cells in planktonic medium and a 53.3% in biofilm was observed. Among the three dyes used, Erythrosyn was the one that , per se, has shown the lowest viability reduction of all, 5% and 14%, indicating its low toxicity in the dark, and it did not affect the biofilm cells. Nevertheless, with TFD, this dye has fostered a higher viability reduction of A. actinomycetemcomitans bacterial cells cultured in planktonic medium and in biofilm of 75% and 67.2%, respectively. Therefore , Erythrosyn was the dye that, per se, has been the most efficient in reducing A. actinomycetemcomitans viability in the conditions studied. These results indicate that TFD reduces A. actinomycetemcomitans viable cells cultivated in planktonic medium and biofilm, indicating that this therapy could be an effective option for the treatment of periodontal disease, with the advantage that it does not show collateral effects like the drug therapy and without developing bacterial resistance, as this has been a major issue with antibiotics treatment.
5

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz

Conti, Elaine Cristina Guerbach [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:41:44Z : No. of bitstreams: 1 conti_ecg_dr_arafo.pdf: 812838 bytes, checksum: c0f89cff921f9b0a2343ffde10308ae3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5.
6

Uso da terapia fotodinâmica para a inativação de Aggregatibacter actinomycetemcomitans em meio planctônico e em biofilme / The use of Photodynamic therapy to inactivate Aggregatibacter actinomycetemcomitans in planktonic medium and biofilm

Rosangela de Carvalho Goulart 28 January 2010 (has links)
A proposta deste trabalho foi de aplicar a Terapia Fotodinâmica (TFD) para avaliar a inativação da bactéria Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans), um patógeno que está associado à endocardite bacteriana, abscessos cerebrais e subcutâneos e principalmente à doença periodontal, que é caracterizada pela inflamação dos tecidos de suporte dos dentes, e consequentemente a perda de dentes. O surgimento de resistência bacteriana a diversas classes de antibióticos vem sendo um problema sério que surge como efeito do uso indiscriminado destes fármacos e até mesmo por fatores adaptativos dos microrganismos. Devido a este fator, várias investigações vêm surgindo com referências satisfatórias no que diz respeito ao emprego da TFD como medida terapêutica. O efeito da TFD foi verificado sobre a cultura da bactéria A. actinomycetemcomitans em meio planctônico e em biofilme. Foi utilizado como agentes fotossensibilizadores Rose bengal, Azul de metileno e Eritrosina, que em baixas concentrações não causam toxicidade para células de fibroblastos e células humanas. Como fonte de luz foi utilizado o fotopolimerizador de resina odontológica, que é de fácil acesso, baixo custo e apresenta uma faixa de emissão de luz de 300 a 800 nm. Rose Bengal até 1 µM não afetou as células de fibroblastos, mas essa mesma concentração sem usar a TFD reduziu a viabilidade de A. actinomycetemcomitans em 41,2%, porém as células de A. actinomycetemcomitans quando cultivadas em biofilme não foram afetadas quando se usou apenas o corante (0,5 e 1,0 µM) ou apenas a luz. Quando se aplicou a TFD Rose Bengal foi o segundo corante (entre os três estudados), que causou uma maior redução da viabilidade celular de A. actinomycetemcomitans cultivadas em meio planctônico 54,4% e o terceiro em reduzir a viabilidade quando cultivadas em biofilme com 45% de redução. Azul de Metileno nas concentrações de 0,5 e 1,0 µM reduziu a viabilidade de A. actinomycetemcomitans em meio planctônico 16 e 24% respectivamente, já sobre o biofilme essa concentração de corante não promoveu redução da viabilidade bacteriana. Com a TFD observou-se uma redução de 50% da viabilidade das células de A. actinomycetemcomitans em meio planctônico e 53,3% em biofilme. Dos três corantes utilizados Eritrosina foi o corante que per se apresentou menor redução da viabilidade 5 e 14%, indicando ter baixa toxicidade, no escuro, e não afetou as células do biofilme de A. actinomycetemcomitan. Porém com a TFD, esse corante promoveu uma maior redução da viabilidade das células bacterianas de A. actinomycetemcomitans cultivadas em meio planctônico e em biofilme 75% e 67,2% respectivamente. Desta forma, a Eritrosina foi o corante mais eficiente em diminuir a viabilidade de A. actinomycetemcomitans nas condições estudadas. Esses resultados indicam que a TFD reduz as células viáveis de A. actinomycetemcomitans cultivadas em meio planctônico e em biofilme, indicando que essa terapia poderá ser uma opção efetiva para o tratamento clinico da doença periodontal, com a vantagem de não apresentar efeitos colaterais como a terapia medicamentosa, nem desenvolver a resistência bacteriana que vem sendo um grande problema do tratamento com antibióticos. / The objective of this work was to apply the photodynamic therapy (TFD) to evaluate the inactivation of the Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans) bacteria, a pathogen that is associated to bacterial endocarditis, subcutaneous and cerebral abscesses and mainly to periodontal disease, which is characterized by inflammation of teeth support tissue and as a consequence, teeth loss. The occurrence of bacterial resistance to many classes of antibiotics has been a serious problem that results from the indiscriminate use of these drugs and also by the adaptation factors of these microorganisms. Due to this, many investigations are being done with satisfactory references regarding the use of TFD as therapeutic step. The TFD effect on A. actinomycetemcomitans bacteria culture in planktonic medium and biofilm was verified. Rose Bengal, methylene Blue and Erythrosyn were used as photosensitizing agents which, in low concentrations are not toxic to fibroblast cells and human cells. The odontological resin photopolymerizer was used as a light source since it is easy accessible, low cost and has a light emission range between 300 and 800nm. Rose Bengal up to 1 µM did not affect the fibroblast cells, but this same concentration without the use of TFD has reduced viability of A. actinomycetemcomitans in 41.2%, but the cells when cultivated in biofilm were not affected when only dye (0.5 and 1.0 µM) or only light were used. When TFD was applied, Rose Bengal was the second dye (among the three studied) to cause the highest reduction of cell viability of A. actinomycetemcomitans cultivated in 54.4% planktonic medium and the third in reducing the viability when cultivated in biofilm, with 45% reduction. Methylene Blue in 0.5 and 1.0 µM concentrations has reduced the viability of A. actinomycetemcomitans in planktonic medium in 16% and 24%, respectively. In biofilm, this dye concentration has not fostered bacterial reduction. With TFD, a 50% reduction of A. actinomycetemcomitans cells in planktonic medium and a 53.3% in biofilm was observed. Among the three dyes used, Erythrosyn was the one that , per se, has shown the lowest viability reduction of all, 5% and 14%, indicating its low toxicity in the dark, and it did not affect the biofilm cells. Nevertheless, with TFD, this dye has fostered a higher viability reduction of A. actinomycetemcomitans bacterial cells cultured in planktonic medium and in biofilm of 75% and 67.2%, respectively. Therefore , Erythrosyn was the dye that, per se, has been the most efficient in reducing A. actinomycetemcomitans viability in the conditions studied. These results indicate that TFD reduces A. actinomycetemcomitans viable cells cultivated in planktonic medium and biofilm, indicating that this therapy could be an effective option for the treatment of periodontal disease, with the advantage that it does not show collateral effects like the drug therapy and without developing bacterial resistance, as this has been a major issue with antibiotics treatment.
7

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz /

Conti, Elaine Cristina Guerbach. January 2006 (has links)
Orientador: José Roberto Cury Saad / Banca: Patrícia dos Santos Jardim / Banca: Luiz Alberto Plácido Penna / Banca: Osmir Batista de Oliveira Júnior / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / Abstract: This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5. / Doutor
8

Avaliação da microdureza superficial da resina composta fotopolimerizada por aparelho de luz halógena e de diodo(LED) em função de opacidade e ação do flúor fosfato acidulado

Firoozmand, Leily Macedo [UNESP] 29 July 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-07-29Bitstream added on 2014-06-13T20:11:59Z : No. of bitstreams: 1 firoozmand_lm_me_sjc.pdf: 463529 bytes, checksum: fe72af5f2a85d677bf7c84e0aa8b1439 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi verificar a influência da opacidade de cor, tipos de aparelhos fotopolimerizadores (luz halogena X led azul) e aplicação tópica do FFA 1,23% na microdureza da resina composta. A resina composta Esthet-X (Dentisply), nas cores A2 e A2-O foram inseridas em uma matriz de aço-inoxidável em cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halogena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 4 grupos com trinta amostras, sendo analisadas a superfície e a base das amostras. Estas foram armazenadas em água destilada, por 24h e posteriormente embutidas em RAAQ. Realizou-se a leitura da microdureza inicial em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. A seguir, foi aplicado o FFA 1,23% por 48 min e uma segunda leitura da microdureza foi realizada. O teste estatístico de ANOVA e Tukey (5%) demonstrou que a microdureza da superfície foi sempre maior que a da base. O aparelho de luz halógena apresentou maiores valores médios de microdureza da resina (57,61 HV) que o aparelho de LED (42,53 HV). Foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade, a resina A2-O apresentou os menores valores. A aplicação do FFA 1,23% promoveu menores valores de microdureza na resina. A opacidade da resina composta, o tipo e fonte polimerizadora, bem como a utilização tópica do FFA 1,23% influenciam no grau de microdureza resina. / The aim of this study was to verify the influence of resin opacity, light curing units (halogen light X blue LED) and topic application of 1.23% acidulated phosphate fluoride (APF) on the resin hardness. The composite resin Esthet-X (Dentsply), shade A2 and A2-O was put in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a halogen light curing unit, XL 3000 (3M) or a blue LED unit, Optilight LD II (Gnatus), for 40s. Four groups with thirty samples were separated and the top and bottom of samples were analyzed. They were stored for 24h and afterwords, built-in acrylic resin. Vickers hardness measurements were made in Vickers Digital Microhardmeter, using 50g load and 30s time. The APF 1.23% was applied for 48 min and a second hardness measurement was done. Statistic test ANOVA and Tukey (5%) demonstrated that top hardness were always higher than bottom. The halogen unit presented higher hardness values (57.61 HV) than LED unit (42.53 HV). Significant differences were found between the hardness values when the opacity was varied, and depth wise the A2-O resin presented the lowest values. The use of 1.23% APF on the resin resulted in the lowest values of hardness. The resin opacity, the light curing unit and the use of 1.23% APF have all influence on the resin hardness.

Page generated in 0.0496 seconds