• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 10
  • 9
  • 9
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Viabilidade clínica de implantes retentores de overdenture mandibular submetidos à carga imediata: avaliação eletromiográfica e análise de frequência de ressonância / Clinical feasibility of mandibular overdenture retainers submitted to immediate load: electromyographic and resonance frequency evaluation

Silva, Ronaldo José da 28 July 2009 (has links)
Milhões de pessoas em todo o mundo ainda não usufruem dos benefícios da osseointegração. O tratamento reabilitador oral com prótese total sobre implantes tem sido cada vez mais adotado pelos especialistas na área de reabilitação oral. Esta é uma alternativa para a obtenção de retenção e estabilidade em tratamentos com próteses totais convencionais, acredita-se que dois implantes são suficientes para reter uma overdenture satisfatoriamente. O objetivo deste estudo foi avaliar dezesseis pacientes, após a instalação de overdenture inferior, por meio da atividade eletromiográfica dos músculos masseteres e temporais, da força de mordida molar e incisiva máxima e da análise da frequência de ressonância da estabilidade inicial e tardia dos implantes utilizados na retenção das overdenture, sob carga imediata. Para estas análises foram utilizados eletromiógrafo Myosystem - Br1; o dinamômetro modelo IDDK Kratos e o aparelho Osstell. A análise estatística foi executada utilizando o teste de medidas repetidas (SPSS 12.0). Verificou-se diminuição da atividade eletromiográfica no repouso, lateralidades e protusão mandibular, aumento da força de mordida molar e incisiva máxima e aumento dos quocientes de estabilidade dos implantes após quinze meses do tratamento reabilitador. Todos os pacientes relataram melhora significativa em todos os aspectos funcionais e estético do sistema estomatognático. Concluiu-se que o uso de overdenture sobre dois implantes inferiores deve-se tornar o tratamento de escolha para indivíduos desdentados inferiores. / Millions of people around the world do not have access to the osseointegration benefits. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in oral medicine field. This is an alternative therapy for retention and stability achievement in total prostheses with conventional treatments, and two implants are enough to establish an overdenture satisfactorily. The objective of this study was to evaluate sixteen patients after inferior overdenture positioning using the electromyographic activity of masseter and temporal muscles to analyze the following parameters: molar and incisive biting strength, resonance frequency of the initial and later implants stability to retain an overdenture under immediate load. For these tests, it was used the Myosystem - BR1 electromyograph; the IDDK Kratos dynamometer and Osstell apparatus. Statistical analysis was performed using the repeated measures test (SPSS 12.0). It was observed a decrease in electromyographic activity during the rest, lateral and mandibular protrusion; increase of the maximal molar and incisive bite strength, and increase of the stability ratios for implants after fifteen months with rehabilitation treatment. All patients reported significant improvement in all functional and aesthetic aspects of the stomatognathic system. It was concluded that the use of inferior overdenture with two implants should become the selected treatment for total mandibular edentulous patients.
2

Viabilidade clínica de implantes retentores de overdenture mandibular submetidos à carga imediata: avaliação eletromiográfica e análise de frequência de ressonância / Clinical feasibility of mandibular overdenture retainers submitted to immediate load: electromyographic and resonance frequency evaluation

Ronaldo José da Silva 28 July 2009 (has links)
Milhões de pessoas em todo o mundo ainda não usufruem dos benefícios da osseointegração. O tratamento reabilitador oral com prótese total sobre implantes tem sido cada vez mais adotado pelos especialistas na área de reabilitação oral. Esta é uma alternativa para a obtenção de retenção e estabilidade em tratamentos com próteses totais convencionais, acredita-se que dois implantes são suficientes para reter uma overdenture satisfatoriamente. O objetivo deste estudo foi avaliar dezesseis pacientes, após a instalação de overdenture inferior, por meio da atividade eletromiográfica dos músculos masseteres e temporais, da força de mordida molar e incisiva máxima e da análise da frequência de ressonância da estabilidade inicial e tardia dos implantes utilizados na retenção das overdenture, sob carga imediata. Para estas análises foram utilizados eletromiógrafo Myosystem - Br1; o dinamômetro modelo IDDK Kratos e o aparelho Osstell. A análise estatística foi executada utilizando o teste de medidas repetidas (SPSS 12.0). Verificou-se diminuição da atividade eletromiográfica no repouso, lateralidades e protusão mandibular, aumento da força de mordida molar e incisiva máxima e aumento dos quocientes de estabilidade dos implantes após quinze meses do tratamento reabilitador. Todos os pacientes relataram melhora significativa em todos os aspectos funcionais e estético do sistema estomatognático. Concluiu-se que o uso de overdenture sobre dois implantes inferiores deve-se tornar o tratamento de escolha para indivíduos desdentados inferiores. / Millions of people around the world do not have access to the osseointegration benefits. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in oral medicine field. This is an alternative therapy for retention and stability achievement in total prostheses with conventional treatments, and two implants are enough to establish an overdenture satisfactorily. The objective of this study was to evaluate sixteen patients after inferior overdenture positioning using the electromyographic activity of masseter and temporal muscles to analyze the following parameters: molar and incisive biting strength, resonance frequency of the initial and later implants stability to retain an overdenture under immediate load. For these tests, it was used the Myosystem - BR1 electromyograph; the IDDK Kratos dynamometer and Osstell apparatus. Statistical analysis was performed using the repeated measures test (SPSS 12.0). It was observed a decrease in electromyographic activity during the rest, lateral and mandibular protrusion; increase of the maximal molar and incisive bite strength, and increase of the stability ratios for implants after fifteen months with rehabilitation treatment. All patients reported significant improvement in all functional and aesthetic aspects of the stomatognathic system. It was concluded that the use of inferior overdenture with two implants should become the selected treatment for total mandibular edentulous patients.
3

Determinação da freqüência de ressonância de antenas tipo microfita triangular e retangular utilizando redes neurais artificiais

Brinhole, Everaldo Ribeiro [UNESP] 14 October 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-10-14Bitstream added on 2014-06-13T18:20:52Z : No. of bitstreams: 1 brinhole_er_me_bauru.pdf: 2082084 bytes, checksum: e9da8790c90b7d67f56ee24ea0858f1c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Cefet - Cornelio Procopio / Neste trabalho, apresenta-se o desenvolvimento de uma metodologia utilizando redes neurais artificiais, para auxiliar na determinação da freqüência de ressonância no projeto de antenas tipo microfita de equipamentos móveis, tanto para antenas retangulares como para antenas triangulares. Compararam-se modelos deterministas e modelos empíricos baseados em Redes Neurais Artificiais (RNA) da literatura pesquisada com os modelos apresentados neste trabalho. Apresentam-se modelos empíricos baseados em RNAs tipo Perceptron Multicamadas (PMC). Os modelos propostos também são capazes de serem integrados em um ambiente CAD (Computed Aided Design) para projetar antenas tipo microfita de equipamentos móveis. / This work presents the development of models that can be used in the design of microstrip antennas for mobile communications. The antennas can be triangular or rectangular. The presented models are compared with deterministic and empirical models based on artificial neural networks (ANN) presented in the literature. The models are based on Perceptron Multilayer (PML). The models can be embedded in CAD systems, in order to design microstrip antennas for mobile communications.
4

Qualidade de rebordos alveolares preservados e sua influência na estabilidade primária e secundária do implante: resultados preliminares de um estudo clínico-microtomográfico controlado e randomizado

Resende, Maraísa Aparecida Pinto 19 September 2018 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-11-22T11:04:41Z No. of bitstreams: 1 maraisaaparecidapintoresende.pdf: 6162684 bytes, checksum: 81f875f5effd371befe15f0ee40da393 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-11-23T12:58:47Z (GMT) No. of bitstreams: 1 maraisaaparecidapintoresende.pdf: 6162684 bytes, checksum: 81f875f5effd371befe15f0ee40da393 (MD5) / Made available in DSpace on 2018-11-23T12:58:47Z (GMT). No. of bitstreams: 1 maraisaaparecidapintoresende.pdf: 6162684 bytes, checksum: 81f875f5effd371befe15f0ee40da393 (MD5) Previous issue date: 2018-09-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo clínico controlado randomizado microtomográfico foi comparar a qualidade óssea entre dois métodos diferentes de preservação do rebordo alveolar e avaliar as estabilidades primária e secundária dos implantes instalados nessas regiões. Vinte pacientes foram divididos aleatoriamente em dois grupos de tratamento após uma única extração dentária. Dez alvéolos foram enxertados com fosfato de cálcio bifásico (SBC, n = 10) associado a um retalho de tecido conjuntivo subepitelial pediculado para o fechamento primário. Dez alvéolos foram selados com uma restauração provisória de pôntico ovóide (PROV, n = 10) sem material de enxertia. Após 12 meses, 9 pacientes perderam-se no acompanhamento e 11 pacientes receberam implantes dentários. As biópsias ósseas foram avaliadas por microtomografia computadorizada (8 μm), quanto às características do osso trabecular. Valores de torque de inserção (ITV) e quociente inicial de estabilidade do implante (ISQI) foram registrados no momento da instalação dos implantes. O ISQ também foi registrado aos 7 dias, 30 dias e 60 dias pós-operatórios. Todos os onze pacientes tiveram os implantes osseointegrados sem intercorrências. O grupo PROV apresentou trabéculas mais espessas (0,17 ± 0,03) em relação ao grupo SBC (0,11 ± 0,03) (p = 0,03). O osso trabecular foi mais anisotrópico em PROV (0,3 ± 0,08) comparado com SBC (0,1 ± 0,07) (p = 0,01). O grupo PROV apresentou menor superfície óssea (26,02 ± 10,36) que o grupo SBC (40,09 ± 10,94) (p = 0,05). Além disso, o PROV apresentou ISQ inicial mais alto (72,3 ± 21) em comparação com o SBC (67 ± 3,9) (p = 0,05). O osso trabecular revelou diferenças na microarquitetura entre os dois métodos de preservação do rebordo alveolar e ambos os métodos foram satisfatórios para a instalação do implante e resultaram em altos valores de ITV e ISQ. / This randomized controlled clinical microtomographic trial aimed to compare the bone quality between two different methods of alveolar ridge preservation and to evaluate the primary and secondary implant stability. Twenty patients were randomly divided into two groups following a single tooth extraction: SBC group (n=10), sockets were grafted with alloplastic biphasic calcium phosphate and a pedicle subepithelial connective tissue flap was used for primary closure; and PROV group (n=10), sockets were sealed with an ovate pontic provisional restoration. After 12 months, 11 patients received dental implants, with nine patients lost to follow-up. Bone biopsies were evaluated by microcomputed-tomography (8 μm) to determine cancellous bone characteristics. Insertion torque values (ITV) and initial implant stability quotient (ISQI) were recorded at installation. The ISQ was also recorded 7, 30 and 60 days after the implant was installed. All implants showed uneventful osseointegration. The PROV group presented thicker trabeculae (0.17±0.03) compared to the SBC group (0.11±0.03; p 0.03). Trabeculae bone was more anisotropic in the PROV group (0.3±0.08) compared with the SBC group (0.1±0.07; p 0.01). The PROV group presented less bone surface (26.02±10.36) than the SBC group (40.09±10.94; p 0.05). Also, PROV showed higher ISQI (72.3±21) than SBC (67±3.9; p 0.05). The characteristics of the trabecular bone differed between the two alveolar ridge preservation methods and the both preservation methods gave satisfactory results with regard to implant placement, and both resulted in high values for ITV and ISQ.
5

Correlação das análises fractal, índices radiomorfométricos e análises de estabilidade primária em sítios de implantes / Correlation of fractal analysis, radiomorphometric indexes and primary stability of dental implants

Zambrana, Nataly Rabelo Mina 15 May 2018 (has links)
O sucesso das cirurgias de implantes depende de diversos fatores como a saúde sistêmica dos pacientes, qualidade e quantidades ósseas disponíveis e, o tipo de macro e microarquitetura dos implantes osseointegráveis. Este estudo propõe avaliar o tecido ósseo em radiografias panorâmicas antes e após cirurgias de implantes correlacionando com análises das Dimensões Fractais (DF), Intensidade de pixel (IP), Índice mentual (IM) e análises de estabilidade primária de implantes (AFR e TI). Foram analisadas 138 regiões de interesse de 50 pacientes, homens e mulheres com idade entre 22 e 77 anos cujas imagens pertencem ao banco de dados do curso de pós-graduação em Implantodontia da Universidade de Santos (Unimes). Foram obtidos dados cirúrgicos do ato da instalação dos implantes, análises de Frequência de Ressonância (AFR) e Torque de Inserção dos implantes (TI) e, com os dados quantitativos obtidos das radiografias panorâmicas antes e após a instalação dos implantes, DF, IP e IM foram realizados testes estatísticos de Correlação de Spearmam, Teste Kruskal Wallis e Wilcoxon para amostras relacionadas com auxílio do software IBM SPSS Advanced Statistics ® (IBM, USA) com nível de significância de 95% (p<0,05). Os resultados obtidos para as Correlações significantes foram entre a Idade e DF (r=-.647) e TI e DF (r=0.434). O teste de Wilcoxon identificou diferença significante (p>0,05) para as amostras relacionadas IP antes e IP depois (p=0,020 e 0,000) entre os grupos 1 e 2. Foram analisadas as possíveis diferenças entre as variáveis independentes para os grupos 1 e 2 em relação a Idade, com diferenças entre IP (p=0,046), TI (p=0,044), AFR_MD (p=0,040) e AFR_VL (p=0,010), em relação ao gênero encontrados diferenças entre as variáveis DF (p=0,039), IP_antes (p=0,001) e IP_depois (p=0,033). O estudo concluiu que a IP pode detectar alterações de mineralização óssea antes e após a instalação de implantes; DF é correlacionada com TI para pacientes jovens (até 45 anos) e, a análise da Idade e Gênero devem ser considerados na avaliação de exames por imagem para planejamento com implantes. / The success of dental implants depends on several factors as patient´s systemic health, bone quality and quantity, geometry of dental implants and their microarquitecture relationship to the alveolar bone. The aim of this study is to assess changes of alveolar bone of panoramic radiographs correlating with Fractal Dimension (FD), Pixel Intensity (PI), Mentual Index (MI) and Implant Stability Quocient (ISQ) measured with Insertion Torque (IT) and Resonance Frequency (RF). 138 regions of interest (ROI) of 50 participants (22 to 77 years old) have been analyzed, all data belonged to the Implantology graduate course of the Universidade de Santos (Unimes). Retrospective surgical data from dental implant surgeries were obtained (RF and IT) and statistically tested with ROI values achieved from DF, PI and MI of panoramic radiographs taken before and after all dental implants placement. Spearman correlation, Kruskal Wallis and Wilcoxon tests were done with the IBM SPSS Advanced Statistics ® software (IBM, USA), level of significance of 95% (p<0,05). Significant correlation was obtained between Age and DF (r=-.647) and TI and DF (r=0.434). Wilcoxon test identified significant difference (p>0,05) for related samples PI before and PI after implant (p=0,020 e 0,000) between groups 1 and 2. Possible differences were analyzed among the independent variables for groups 1 and 2 related to Age, the results showed differences between PI (p=0,046), IT (p=0,044), RF_MD (p=0,040) e RF_VL (p=0,010), between Gender the results showed differences between the variables FD (p=0,039), PI_before (p=0,001) e PI_after (p=0,033). The study concluded that PI can detect bone mineralization changes before and after dental implant placement. FD correlates with the variable IT for younger participants (22 to 45 years old). Age and Gender should be considered regarding imaging exams tests (FD and PI) for dental implant planning.
6

Avaliação da estabilidade primária de implantes convencionais e modificados por meio de ensaios de desempenho, frequência de ressonância e análise microestrutural / Evaluation of primary stability of conventional and modified implants by the performance tests, resonance frequency and microstructural analysis

Valente, Mariana Lima da Costa 09 October 2014 (has links)
A estabilidade primária dos implantes odontológicos é determinante para a osseointegração e depende dos fatores qualidade, quantidade óssea e tipo de implante. O objetivo desse estudo foi avaliar a influência do formato de implantes convencionais e modificados e do tipo de substrato na estabilidade primária por meio da correlação de ensaios de desempenho e frequência de ressonância e análise microestrutural. No estudo foram utilizados 54 implantes Neodent®: 27 cilíndricos, sendo 9 hexágono externo (Titamax Ti Cortical - 4,0 mm x 11 mm), 9 hexágono interno (Titamax II Plus - 3,75 mm x 11 mm) e 9 cone morse (Titamax CM - 4,0 mm x 11 mm); e 27 implantes cônicos de 4,3 mm x 10 mm, sendo 9 hexágono externo (Alvim Ti), 9 hexágono interno (Alvim II Plus) e 9 cone morse (Alvim CM). Os implantes foram inseridos em osso artificial da marca Nacional® nas densidades de 15, 20 e 40 PCF e osso de costela suína. Para os ensaios de desempenho foi quantificado o torque de inserção com um torquímetro digital e a força máxima de arrancamento utilizando uma Máquina Universal de Ensaios. Para avaliar a frequência de ressonância foi utilizado o aparelho Ostell® e para a análise morfológica um Microscópio Eletrônico de Varredura, sob aumentos de 40 e 100 vezes. Após a realização dos ensaios com os implantes convencionais, os modelos Alvim CM e Titamax Ti Cortical (n=9) tiveram sua morfologia externa alterada com a prolongação dos chanfros desde o terço apical até o nível da plataforma protética e foram submetidos aos mesmos testes propostos para os parafusos originais. Verificada a normalidade dos dados utilizou-se o teste de análise de variância ANOVA, comparação de médias Tukey (&alpha;=5%) e correlação de Pearson. Para os implantes convencionais, o Alvim CM apresentou maior média em todos os ensaios realizados, sendo estatisticamente diferente dos implantes cilíndricos quando analisado o torque de inserção no osso (73,33 N.cm) e força de arrancamento na poliuretana de 40 PCF (910,36 N) e osso (553,79 N). Os implantes Titamax II Plus tiveram as menores médias, diferente estatisticamente dos cônicos quando analisado o torque de inserção (22,22 N.cm) e frequência de ressonância no osso (72,83 ISQ) e força de arrancamento na poliuretana de 40 PCF (61,97 N) e osso (86,40 N). A análise dos ensaios de desempenho e frequência de ressonância apresentou correlação moderada de acordo com o p de Pearson (0,30 a 0,70) e a comparação entre as fotomicrografias não mostrou alteração morfológica dos implantes. A modificação realizada no parafuso Alvim CM proporcionou um aumento significativo no torque de inserção (p=0,000), diminuição das médias de arrancamento (p=0,000) e manteve semelhança com as médias de frequência de ressonância (p=0,169) quando comparado ao implante convencional. O Titamax Ti modificado aumentou significativamente o torque de inserção (p=0,043) e provocou diminuição significativa para a frequência de ressonância (p=0,002) e ensaio de arrancamento (p=0,000). Conclui-se que o formato dos implantes interfere na estabilidade primária, sendo os implantes cônicos indutores de maior estabilidade. A análise de correlação das metodologias empregadas demonstrou a associação positiva das mesmas para complementação da análise da estabilidade primária / The primary stability of dental implants is critical for osseointegration and depends on factors quality, bone quantity and type of implant. The aim of this study was to evaluate the influence of conventional and modified implants and the type of substrate shape on primary stability through the correlation of performance tests and frequency of resonance and microstructural analysis. In the study 54 Neodent® implants were used: 27 cylindrical, 9 hexagonal (Titamax Ti Cortical - 4.0 mm x 11 mm), 9 internal hexagon (Titamax II Plus - 3.75 mm x 11 mm) and 9 morse taper (Titamax CM - 4.0 mm x 11 mm); and 27 tapered implants of 4.3 mm x 10 mm and 9 external hexagon (Alvim Ti), 9 internal hexagon (Alvim II Plus) and 9 morse taper (Alvim CM). The implants were inserted into artificial bone of National ® brand at densities of 15, 20 and 40 PCF and pork rib bone. For testing the performance was quantified insertion torque with a digital torque meter and the maximum pullout strength using a universal testing machine. To evaluate the resonance frequency was used Ostell ® device and the morphological parsing an Scanning Electron Microscope under increases of 40 and 100 times. After the tests with conventional implants, models CM Alvim and Titamax Cortical Ti (n=9) had their external morphology changed with the prolongation of the bevels from the apical to the level of prosthetic platform and underwent the same tests proposed for the original screws. Checked for normality of the data used in the test of ANOVA, Tukey comparison (&alpha;=5%) and Pearson correlation. For conventional implants, the CM Alvim showed higher average in all tests, with statistically different when analyzed cylindrical implant insertion torque on bone (73.33 N.cm) and pullout strength in polyurethane 40 PCF (910.36 N) and bone (553.79 N). Implants Titamax II Plus had the lowest average, statistically different when analyzed the tapered insertion torque (22.22 N.cm) and resonance frequency in bone (72.83 ISQ) and pullout strength in 40 PCF polyurethane (61.97 N) and bone (86.40 N). The analysis of the performance tests and had moderate resonance frequency correlation according op Pearson (0.30 to 0.70) and comparing the photomicrographs showed no morphological alteration of the implants. The modification made to the screw Alvim CM provided a significant increase in insertion torque (p=0.000), decrease of average pullout (p=0.000) and remained similar to the average resonance frequency (p=0.169) when compared to the implant conventional. The Titamax Ti modified significantly increased insertion torque (p=0.043) and caused a significant decrease in the resonance frequency (p=0.002) and pullout test (p=0.000). It is concluded that the shape of the implants interfere with the primary stability, with the inductors tapered implants stability. Correlation analysis of the methodologies used showed a possible association of these for further analysis of primary stability
7

Projeto e análise de dispositivo dinâmico para o estudo das vibrações induzidas por escoamentos bifásicos / Design and analysis of a dynamic structure for the study of multiphase flow induced vibration

Álvarez Briceño, Ricardo Patricio 30 May 2014 (has links)
As Vibrações Induzidas por Escoamentos (VIEs) são dos problemas dinâmicos mais importantes no projeto de trocadores de calor de tipo carcaça e tubos. Esta interação fluido - estrutura pode gerar vibrações de grande amplitude dos tubos ou partes internas do equipamento, o que pode provocar o impacto entre componentes e até falha por fadiga. Várias bancadas experimentais têm sido construídas para o estudo desta interação fluido - estrutura, no entanto, alguns mecanismos de vibração, principalmente aqueles relacionados com escoamentos bifásicos, não são completamente compreendidos. Portanto, neste trabalho, o projeto de uma estrutura dinâmica para o estudo das vibrações induzidas por escoamento bifásico é apresentado. Esta estrutura é composta por um sistema de fios de aço tensionados que permitem que a primeira frequência de ressonância do tubo seja sintonizada. O tubo instrumentado foi instalado numa seção de testes de tubos rígidos em configuração triangular normal com uma razão de passo transversal e diâmetro de 1,26. Os resultados experimentais foram contrastados com uma modelagem teórica desenvolvida para esta estrutura dinâmica. Pôde-se verificar que a primeira frequência de ressonância e seu fator de amortecimento coincidem com os valores estimados pelo modelo, enquanto que a segunda frequência de ressonância apresenta valor teórico 6,6% maior do que o experimental. A seguir, um estudo experimental no ar foi desenvolvido para o reconhecimento dos modos de vibração e as frequências de ressonância da estrutura dinâmica. O fator de amortecimento no ar também foi estimado, o método de Kennedy - Pancu combinado com o algoritmo ERA foi usado para este fim. Assim que a primeira frequência de ressonância foi reconhecida e sintonizada, testes em escoamentos de água foram realizados. A influência da velocidade do escoamento monofásico de água na amplitude de vibração e nas características da Densidade Espectral (PSD) de aceleração foi analisada. Finalmente, testes em escoamento bifásico foram feitos, a sensibilidade do tubo ao escoamento bifásico fica evidente quando analisadas as amplitudes nas PSDs. Além disso, a influência da fração de vazio na amplitude de vibração e no fator de amortecimento foi revisada, no entanto, resultados de estudos anteriores não foram conferidos pelo alto amortecimento concentrado introduzido por alguns elementos construtivos utilizados. / Flow - Induced Vibration (FIV) is the most critical dynamic issue in the design of heat exchangers. This fluid - structure phenomenon may generate high amplitude vibration of tubes or structural parts, which may lead to impacts between internal components or even failure due to fatigue. Many test benches have been constructed to study this fluid - structure interactions, however, some vibration mechanisms, mostly those related to multiphase flow, are not yet fully understood. Therefore, in this work, the design of a dynamic structure for the study of multiphase flow induced vibration is presented. This structure is composed by a system of tensioned piano wires that allow the first natural frequency of the instrumented tube to be calibrated. The tube was installed in a rigid bundle configured in a normal triangular pattern with pitch-todiameter ratio of 1.26. Then, an experimental study in air environment was performed aiming at addressing the mode shapes and resonance frequencies of the dynamic structure. The damping ratio in air environment was also estimated, the Kennedy - Pancu method in combination with the Eigensystem Realization Algorithm have been used to that purpose. Experimental results in air were compared with a theoretical model. The first resonance frequency and its damping factor presented a good agreement with the model, while the second resonance frequency deviated some 6,6% from the predicted value. Tests in water and multiphase flow were also performed. The influence of water flow velocity on vibration amplitudes and on the Power Spectrum Densities (PSDs) has been analyzed. Finally, tests for two - phase water/air flow were carried out; the tube sensitivity to multiphase flow is evident when the vibration level in acceleration PSDs is by analyzed. Also, the influence of void fraction on vibration amplitude and damping ratio have been addressed, however, previous studies could not be validated due to the high damping introduced by some constructive elements of the structure.
8

Avaliação da estabilidade primária de implantes convencionais e modificados por meio de ensaios de desempenho, frequência de ressonância e análise microestrutural / Evaluation of primary stability of conventional and modified implants by the performance tests, resonance frequency and microstructural analysis

Mariana Lima da Costa Valente 09 October 2014 (has links)
A estabilidade primária dos implantes odontológicos é determinante para a osseointegração e depende dos fatores qualidade, quantidade óssea e tipo de implante. O objetivo desse estudo foi avaliar a influência do formato de implantes convencionais e modificados e do tipo de substrato na estabilidade primária por meio da correlação de ensaios de desempenho e frequência de ressonância e análise microestrutural. No estudo foram utilizados 54 implantes Neodent®: 27 cilíndricos, sendo 9 hexágono externo (Titamax Ti Cortical - 4,0 mm x 11 mm), 9 hexágono interno (Titamax II Plus - 3,75 mm x 11 mm) e 9 cone morse (Titamax CM - 4,0 mm x 11 mm); e 27 implantes cônicos de 4,3 mm x 10 mm, sendo 9 hexágono externo (Alvim Ti), 9 hexágono interno (Alvim II Plus) e 9 cone morse (Alvim CM). Os implantes foram inseridos em osso artificial da marca Nacional® nas densidades de 15, 20 e 40 PCF e osso de costela suína. Para os ensaios de desempenho foi quantificado o torque de inserção com um torquímetro digital e a força máxima de arrancamento utilizando uma Máquina Universal de Ensaios. Para avaliar a frequência de ressonância foi utilizado o aparelho Ostell® e para a análise morfológica um Microscópio Eletrônico de Varredura, sob aumentos de 40 e 100 vezes. Após a realização dos ensaios com os implantes convencionais, os modelos Alvim CM e Titamax Ti Cortical (n=9) tiveram sua morfologia externa alterada com a prolongação dos chanfros desde o terço apical até o nível da plataforma protética e foram submetidos aos mesmos testes propostos para os parafusos originais. Verificada a normalidade dos dados utilizou-se o teste de análise de variância ANOVA, comparação de médias Tukey (&alpha;=5%) e correlação de Pearson. Para os implantes convencionais, o Alvim CM apresentou maior média em todos os ensaios realizados, sendo estatisticamente diferente dos implantes cilíndricos quando analisado o torque de inserção no osso (73,33 N.cm) e força de arrancamento na poliuretana de 40 PCF (910,36 N) e osso (553,79 N). Os implantes Titamax II Plus tiveram as menores médias, diferente estatisticamente dos cônicos quando analisado o torque de inserção (22,22 N.cm) e frequência de ressonância no osso (72,83 ISQ) e força de arrancamento na poliuretana de 40 PCF (61,97 N) e osso (86,40 N). A análise dos ensaios de desempenho e frequência de ressonância apresentou correlação moderada de acordo com o p de Pearson (0,30 a 0,70) e a comparação entre as fotomicrografias não mostrou alteração morfológica dos implantes. A modificação realizada no parafuso Alvim CM proporcionou um aumento significativo no torque de inserção (p=0,000), diminuição das médias de arrancamento (p=0,000) e manteve semelhança com as médias de frequência de ressonância (p=0,169) quando comparado ao implante convencional. O Titamax Ti modificado aumentou significativamente o torque de inserção (p=0,043) e provocou diminuição significativa para a frequência de ressonância (p=0,002) e ensaio de arrancamento (p=0,000). Conclui-se que o formato dos implantes interfere na estabilidade primária, sendo os implantes cônicos indutores de maior estabilidade. A análise de correlação das metodologias empregadas demonstrou a associação positiva das mesmas para complementação da análise da estabilidade primária / The primary stability of dental implants is critical for osseointegration and depends on factors quality, bone quantity and type of implant. The aim of this study was to evaluate the influence of conventional and modified implants and the type of substrate shape on primary stability through the correlation of performance tests and frequency of resonance and microstructural analysis. In the study 54 Neodent® implants were used: 27 cylindrical, 9 hexagonal (Titamax Ti Cortical - 4.0 mm x 11 mm), 9 internal hexagon (Titamax II Plus - 3.75 mm x 11 mm) and 9 morse taper (Titamax CM - 4.0 mm x 11 mm); and 27 tapered implants of 4.3 mm x 10 mm and 9 external hexagon (Alvim Ti), 9 internal hexagon (Alvim II Plus) and 9 morse taper (Alvim CM). The implants were inserted into artificial bone of National ® brand at densities of 15, 20 and 40 PCF and pork rib bone. For testing the performance was quantified insertion torque with a digital torque meter and the maximum pullout strength using a universal testing machine. To evaluate the resonance frequency was used Ostell ® device and the morphological parsing an Scanning Electron Microscope under increases of 40 and 100 times. After the tests with conventional implants, models CM Alvim and Titamax Cortical Ti (n=9) had their external morphology changed with the prolongation of the bevels from the apical to the level of prosthetic platform and underwent the same tests proposed for the original screws. Checked for normality of the data used in the test of ANOVA, Tukey comparison (&alpha;=5%) and Pearson correlation. For conventional implants, the CM Alvim showed higher average in all tests, with statistically different when analyzed cylindrical implant insertion torque on bone (73.33 N.cm) and pullout strength in polyurethane 40 PCF (910.36 N) and bone (553.79 N). Implants Titamax II Plus had the lowest average, statistically different when analyzed the tapered insertion torque (22.22 N.cm) and resonance frequency in bone (72.83 ISQ) and pullout strength in 40 PCF polyurethane (61.97 N) and bone (86.40 N). The analysis of the performance tests and had moderate resonance frequency correlation according op Pearson (0.30 to 0.70) and comparing the photomicrographs showed no morphological alteration of the implants. The modification made to the screw Alvim CM provided a significant increase in insertion torque (p=0.000), decrease of average pullout (p=0.000) and remained similar to the average resonance frequency (p=0.169) when compared to the implant conventional. The Titamax Ti modified significantly increased insertion torque (p=0.043) and caused a significant decrease in the resonance frequency (p=0.002) and pullout test (p=0.000). It is concluded that the shape of the implants interfere with the primary stability, with the inductors tapered implants stability. Correlation analysis of the methodologies used showed a possible association of these for further analysis of primary stability
9

Projeto e análise de dispositivo dinâmico para o estudo das vibrações induzidas por escoamentos bifásicos / Design and analysis of a dynamic structure for the study of multiphase flow induced vibration

Ricardo Patricio Álvarez Briceño 30 May 2014 (has links)
As Vibrações Induzidas por Escoamentos (VIEs) são dos problemas dinâmicos mais importantes no projeto de trocadores de calor de tipo carcaça e tubos. Esta interação fluido - estrutura pode gerar vibrações de grande amplitude dos tubos ou partes internas do equipamento, o que pode provocar o impacto entre componentes e até falha por fadiga. Várias bancadas experimentais têm sido construídas para o estudo desta interação fluido - estrutura, no entanto, alguns mecanismos de vibração, principalmente aqueles relacionados com escoamentos bifásicos, não são completamente compreendidos. Portanto, neste trabalho, o projeto de uma estrutura dinâmica para o estudo das vibrações induzidas por escoamento bifásico é apresentado. Esta estrutura é composta por um sistema de fios de aço tensionados que permitem que a primeira frequência de ressonância do tubo seja sintonizada. O tubo instrumentado foi instalado numa seção de testes de tubos rígidos em configuração triangular normal com uma razão de passo transversal e diâmetro de 1,26. Os resultados experimentais foram contrastados com uma modelagem teórica desenvolvida para esta estrutura dinâmica. Pôde-se verificar que a primeira frequência de ressonância e seu fator de amortecimento coincidem com os valores estimados pelo modelo, enquanto que a segunda frequência de ressonância apresenta valor teórico 6,6% maior do que o experimental. A seguir, um estudo experimental no ar foi desenvolvido para o reconhecimento dos modos de vibração e as frequências de ressonância da estrutura dinâmica. O fator de amortecimento no ar também foi estimado, o método de Kennedy - Pancu combinado com o algoritmo ERA foi usado para este fim. Assim que a primeira frequência de ressonância foi reconhecida e sintonizada, testes em escoamentos de água foram realizados. A influência da velocidade do escoamento monofásico de água na amplitude de vibração e nas características da Densidade Espectral (PSD) de aceleração foi analisada. Finalmente, testes em escoamento bifásico foram feitos, a sensibilidade do tubo ao escoamento bifásico fica evidente quando analisadas as amplitudes nas PSDs. Além disso, a influência da fração de vazio na amplitude de vibração e no fator de amortecimento foi revisada, no entanto, resultados de estudos anteriores não foram conferidos pelo alto amortecimento concentrado introduzido por alguns elementos construtivos utilizados. / Flow - Induced Vibration (FIV) is the most critical dynamic issue in the design of heat exchangers. This fluid - structure phenomenon may generate high amplitude vibration of tubes or structural parts, which may lead to impacts between internal components or even failure due to fatigue. Many test benches have been constructed to study this fluid - structure interactions, however, some vibration mechanisms, mostly those related to multiphase flow, are not yet fully understood. Therefore, in this work, the design of a dynamic structure for the study of multiphase flow induced vibration is presented. This structure is composed by a system of tensioned piano wires that allow the first natural frequency of the instrumented tube to be calibrated. The tube was installed in a rigid bundle configured in a normal triangular pattern with pitch-todiameter ratio of 1.26. Then, an experimental study in air environment was performed aiming at addressing the mode shapes and resonance frequencies of the dynamic structure. The damping ratio in air environment was also estimated, the Kennedy - Pancu method in combination with the Eigensystem Realization Algorithm have been used to that purpose. Experimental results in air were compared with a theoretical model. The first resonance frequency and its damping factor presented a good agreement with the model, while the second resonance frequency deviated some 6,6% from the predicted value. Tests in water and multiphase flow were also performed. The influence of water flow velocity on vibration amplitudes and on the Power Spectrum Densities (PSDs) has been analyzed. Finally, tests for two - phase water/air flow were carried out; the tube sensitivity to multiphase flow is evident when the vibration level in acceleration PSDs is by analyzed. Also, the influence of void fraction on vibration amplitude and damping ratio have been addressed, however, previous studies could not be validated due to the high damping introduced by some constructive elements of the structure.
10

Correlação das análises fractal, índices radiomorfométricos e análises de estabilidade primária em sítios de implantes / Correlation of fractal analysis, radiomorphometric indexes and primary stability of dental implants

Nataly Rabelo Mina Zambrana 15 May 2018 (has links)
O sucesso das cirurgias de implantes depende de diversos fatores como a saúde sistêmica dos pacientes, qualidade e quantidades ósseas disponíveis e, o tipo de macro e microarquitetura dos implantes osseointegráveis. Este estudo propõe avaliar o tecido ósseo em radiografias panorâmicas antes e após cirurgias de implantes correlacionando com análises das Dimensões Fractais (DF), Intensidade de pixel (IP), Índice mentual (IM) e análises de estabilidade primária de implantes (AFR e TI). Foram analisadas 138 regiões de interesse de 50 pacientes, homens e mulheres com idade entre 22 e 77 anos cujas imagens pertencem ao banco de dados do curso de pós-graduação em Implantodontia da Universidade de Santos (Unimes). Foram obtidos dados cirúrgicos do ato da instalação dos implantes, análises de Frequência de Ressonância (AFR) e Torque de Inserção dos implantes (TI) e, com os dados quantitativos obtidos das radiografias panorâmicas antes e após a instalação dos implantes, DF, IP e IM foram realizados testes estatísticos de Correlação de Spearmam, Teste Kruskal Wallis e Wilcoxon para amostras relacionadas com auxílio do software IBM SPSS Advanced Statistics ® (IBM, USA) com nível de significância de 95% (p<0,05). Os resultados obtidos para as Correlações significantes foram entre a Idade e DF (r=-.647) e TI e DF (r=0.434). O teste de Wilcoxon identificou diferença significante (p>0,05) para as amostras relacionadas IP antes e IP depois (p=0,020 e 0,000) entre os grupos 1 e 2. Foram analisadas as possíveis diferenças entre as variáveis independentes para os grupos 1 e 2 em relação a Idade, com diferenças entre IP (p=0,046), TI (p=0,044), AFR_MD (p=0,040) e AFR_VL (p=0,010), em relação ao gênero encontrados diferenças entre as variáveis DF (p=0,039), IP_antes (p=0,001) e IP_depois (p=0,033). O estudo concluiu que a IP pode detectar alterações de mineralização óssea antes e após a instalação de implantes; DF é correlacionada com TI para pacientes jovens (até 45 anos) e, a análise da Idade e Gênero devem ser considerados na avaliação de exames por imagem para planejamento com implantes. / The success of dental implants depends on several factors as patient´s systemic health, bone quality and quantity, geometry of dental implants and their microarquitecture relationship to the alveolar bone. The aim of this study is to assess changes of alveolar bone of panoramic radiographs correlating with Fractal Dimension (FD), Pixel Intensity (PI), Mentual Index (MI) and Implant Stability Quocient (ISQ) measured with Insertion Torque (IT) and Resonance Frequency (RF). 138 regions of interest (ROI) of 50 participants (22 to 77 years old) have been analyzed, all data belonged to the Implantology graduate course of the Universidade de Santos (Unimes). Retrospective surgical data from dental implant surgeries were obtained (RF and IT) and statistically tested with ROI values achieved from DF, PI and MI of panoramic radiographs taken before and after all dental implants placement. Spearman correlation, Kruskal Wallis and Wilcoxon tests were done with the IBM SPSS Advanced Statistics ® software (IBM, USA), level of significance of 95% (p<0,05). Significant correlation was obtained between Age and DF (r=-.647) and TI and DF (r=0.434). Wilcoxon test identified significant difference (p>0,05) for related samples PI before and PI after implant (p=0,020 e 0,000) between groups 1 and 2. Possible differences were analyzed among the independent variables for groups 1 and 2 related to Age, the results showed differences between PI (p=0,046), IT (p=0,044), RF_MD (p=0,040) e RF_VL (p=0,010), between Gender the results showed differences between the variables FD (p=0,039), PI_before (p=0,001) e PI_after (p=0,033). The study concluded that PI can detect bone mineralization changes before and after dental implant placement. FD correlates with the variable IT for younger participants (22 to 45 years old). Age and Gender should be considered regarding imaging exams tests (FD and PI) for dental implant planning.

Page generated in 0.0506 seconds