• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 382
  • 7
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 394
  • 223
  • 126
  • 101
  • 76
  • 72
  • 70
  • 55
  • 53
  • 52
  • 51
  • 47
  • 42
  • 42
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estados limites de fundações considerando a resposta da superestrutura / Limits states of foundations considering structure response

Camargo, Fabiana Ester de January 2002 (has links)
A superestrutura, suas fundações e o solo formam um sistema. É evidente, portanto, a necessidade de um estudo que englobe todo o sistema, estabelecendo qual a influência dos deslocamentos do solo na superestrutura. Toda fundação sofre deslocamentos verticais, horizontais ou rotacionais, conforme a solicitação a qual está submetida. Os deslocamentos, conforme sua magnitude, terão uma influência sobre a estrutura, que vai desde uma simples redistribuição de cargas até o colapso. O objetivo deste trabalho é analisar a influência dos deslocamentos das fundações em torres de linhas de transmissão de energia. A metodologia adotada foi analisar as torres com apoios indeslocáveis (hipótese usual) e depois substituí-los por apoios flexíveis para verificar o efeito dos deslocamentos das fundações na distribuição das solicitações nas barras das torres. Este trabalho tem, adicionalmente, a intenção de contribuir aos grupos de estruturas e fundações, WG22-08 e WG22-07 da CIGRÉ em âmbito internacional, de forma articulada e coordenada. Assim sendo, este trabalho também objetiva preliminarmente avaliar algumas implicações de procedimentos usuais de análise e projeto, interrelacionados ao objetivo central, incluindo incertezas na modelagem para a previsão do comportamento estrutural sob carregamentos externos e deslocamentos das fundações. Com base nos resultados das aplicações estudadas, propõe-se um procedimento de caráter preliminar, para obtenção de coeficientes a serem aplicados no projeto das fundações e da torre. Estes coeficientes teriam as funções de limitar o deslocamento das fundações sob ação do carregamento máximo e dimensionar a torre de maneira que acréscimos de solicitações nas barras devido ao deslocamento limite possam ser absorvidos pela estrutura. / The structure and its foundations have to be regarded as a system. Therefore, it is clear the importance of studies leading to take into account the influence of foundation displacements on the structure performance. Any foundation undergoes displacements when is subjected to loading. Depending of the magnitude of such displacements, their influence may vary from a simple balance of member forces up to the structure or component collapse. The objective of this dissertation is to analyse the influence of displacements on structures, and in particular on transmission line tower for electrical energy. The approach adopted in this work was to initially consider the tower on fixed foundations and, afterwards, to replace these conditions by others allowing displacements and verify the influence on the member force distribution. In addition, this dissertation also aims to contribute to the Projects of CIGRÉ WG22-08, as well as of WG22-07, "Transmission Line Structures” and “Transmission Line Foundations", respectively. These Projects have a wide range of objectives which may be summarised by "to reach a better understanding of the capability of standard design models to predict the actual behaviour and the actual performance of structures and foundations of transmission lines". Based on the results of analyses carried out, a preliminary approach to establish a "design coefficient" for the combined design of tower and foundation is proposed. This coefficient would establish allowable foundation displacements, as well as the ultimate bar strength, in a such way to obtain a co-ordinated design of the system "structurefoundation".
32

Avaliação numérica de reforço de grupo de estacas pela introdução de estacas adicionais

Cordeiro, Ary Franck Baia 28 March 2007 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2007. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2013-04-16T14:28:28Z No. of bitstreams: 1 2007_AryFranckBaiaCordeiro.pdf: 3135038 bytes, checksum: 2b3649a28968cf8fd75cf0a8eac3e8b1 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2013-04-16T15:31:16Z (GMT) No. of bitstreams: 1 2007_AryFranckBaiaCordeiro.pdf: 3135038 bytes, checksum: 2b3649a28968cf8fd75cf0a8eac3e8b1 (MD5) / Made available in DSpace on 2013-04-16T15:31:16Z (GMT). No. of bitstreams: 1 2007_AryFranckBaiaCordeiro.pdf: 3135038 bytes, checksum: 2b3649a28968cf8fd75cf0a8eac3e8b1 (MD5) / A presente dissertação faz uma revisão geral da evolução do uso do radier estaqueado, as diferenças deste tipo de fundação com os grupos estaqueados convencionais e como esta concepção é importante para avaliar o dano em uma obra. São apresentados os principais danos ocorridos nas fundações estaqueadas e alguns casos reportados na literatura sobre reforço de fundações, previsão de capacidade de carga e recalque. Comenta-se a respeito de dois programas computacionais desenvolvidos especialmente para estas fundações. Alguns casos hipotéticos de grupos de estacas foram analisados, empregando-se um método misto e um programa em elementos finitos (3-D) para avaliar os comportamentos destes casos. Para os fatores de interação foram observadas algumas divergências entre os resultados obtidos por diferentes metodologias de cálculo, mostrando que se deve ter cuidado ao comparar estes resultados, pois, estes podem ter significante influência nos resultados das análises. Foram realizadas análises paramétricas para três grupos originais e destes foram analisadas várias configurações de dano e de reforço, este com propriedades similares e distintas das estacas originais, as quais objetivaram analisar a influência das diversas configurações apresentadas, assim como de cada componente do sistema. Estes resultados são analisados e comparados com as previsões feitas pelo método híbrido (GARP). E finalmente foram apresentados os resultados das análises de capacidade de carga, de resposta carga x recalque do sistema de fundação e a parcela de carga absorvida por cada elemento de tal sistema nas três situações: grupo intacto, grupo danificado e grupo reforçado, baseados, também, nos fatores de segurança por cada estaca e dos fatores de segurança globais. _______________________________________________________________________________________ ABSTRACT / A review of the evolution of the use of piled raft, the differences of this foundation type with the conventional pile groups and as it these conception is important to evaluate the damage in a foundation. The main damages happened in the foundations are presented and some cases moderated in the literature on reinforcement of foundations, forecast of bearing capacity and settlement. It is commented about two softwares developed especially for these foundations. Some hypothetical cases of pile groups were analyzed, being used a mixed method and a program in finite elements (3-D) to evaluate the behaviors of these cases. For the interaction factors some were observed divergences among the results obtained by different calculation methodologies, showing that one should be careful when comparing these results, because, these can have significant influence in the results of the analyses. Parametric analyses were accomplished for three original groups and of these several damage configurations were analyzed and of reinforcement, this with similar properties and different from the original piles, which aimed at to analyze the influence of the several presented configurations, as well as of each component of the system. These results are analyzed and compared with the forecasts done by the hybrid method (GARP). It is finally presented the results of the analyses of load capacity were presented, of answer “load x settlement” of the foundation system and the portion of absorbed load for each element of the system in the three situations: the intact group, the damaged group and reinforced group, based, also, in safety factors for each pile and of the global safety factors.
33

Influência pluviométricas na umidade de solos tropicais como indicador da sucção aplicado à fundações

Souza, Mauro Aparecido Lessa 26 October 2005 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2005. / Submitted by Alexandre Marinho Pimenta (alexmpsin@hotmail.com) on 2009-11-05T20:32:56Z No. of bitstreams: 2 sucção x umidade.pdf: 35516 bytes, checksum: 84c34ff08a89306f7c52dd184aa0cf0b (MD5) dissertação MAURO APARECIDO LESSA DE SOUZA.pdf: 11605668 bytes, checksum: 5a28e954bb0002262a986d5c39d9e61b (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2011-02-03T13:03:37Z (GMT) No. of bitstreams: 2 sucção x umidade.pdf: 35516 bytes, checksum: 84c34ff08a89306f7c52dd184aa0cf0b (MD5) dissertação MAURO APARECIDO LESSA DE SOUZA.pdf: 11605668 bytes, checksum: 5a28e954bb0002262a986d5c39d9e61b (MD5) / Made available in DSpace on 2011-02-03T13:03:37Z (GMT). No. of bitstreams: 2 sucção x umidade.pdf: 35516 bytes, checksum: 84c34ff08a89306f7c52dd184aa0cf0b (MD5) dissertação MAURO APARECIDO LESSA DE SOUZA.pdf: 11605668 bytes, checksum: 5a28e954bb0002262a986d5c39d9e61b (MD5) Previous issue date: 2005-10 / O perfil geológico-geotécnico do solo da cidade de Brasília, DF, possui características típicas de solos tropicais. É um perfil profundamente intemperizado, não apresenta lençol freático nem em camadas mais profundas em nenhum período do ano, por isso o solo nunca se encontra saturado naturalmente. Devido a essas boas condições de drenagem este solo apresenta nos horizontes A e B argila com estrutura macroporosa com elevado índice de vazios. Esta característica é responsável pela colapsibilidade do solo e, por conseguinte, é um grande problema para as fundações assentes neste solo. Por outro lado, a não saturação do solo, é responsável por ele apresentar uma grande parcela de coesão aparente devido à tensão de sucção matricial. Esta propriedade, a qual estimulou a elaboração desta dissertação, pode ser utilizada como uma parcela complementar na capacidade de suporte do solo, ao se projetar uma fundação, se for bem entendido o seu comportamento. Como o único elemento que influencia a sucção matricial no solo está diretamente relacionada ao grau de saturação, e esta, por sua vez, está relacionada com a umidade do solo a qual varia com os índices pluviométricos, então, esta pesquisa utilizou uma mini-estação meteorológica para monitorar os dados climatológicos no período de um ano e paralelamente obtiveram-se vários perfis de umidade do solo distribuídos neste mesmo período. Realizaram-se, ainda, ensaios de DPL (Penetrômetro Dinâmico Leve) durante este período para se verificar no campo a variação de resistência à penetração do solo ao longo do ano. Obtiveram-se as curvas características do solo para cada metro do perfil e em função das umidades do solo obtidas durante a pesquisa, somadas às informações climatológicas obtidas, pôde-se recomendar neste trabalho um valor máximo da tensão de sucção matricial a considerar em um projeto geotécnico para o solo aqui estudado. ____________________________________________________________________________ ABSTRACT / The city of Brasilia has a soil whose characteristics of the geological-geotechnical profile is of a typical tropical soil. Its profile is deeply weathering, it does not present groundwater, at least in deeper layers in no period of the year, as a consequence of it, the soil is never naturally saturated. In this kind of soil, due to its good draining conditions, within A and B horizontals, the found clay is macro porous and has a high void ratio structure. This characteristic is responsible for the collapse of the soil and, consequently, it is a great problem for the foundation's seat in this kind of soil. On the other hand, with non saturated soil, it is natural that it presents a great parcel of apparent cohesion due to the tension of matrix suction. This characteristic, which stimulated the elaboration of this dissertation, can be used as a complementary parcel in the capacity of support of the soil, to design a foundation, if well understood its behavior. As the only element that influences the matrix suction in the soil directly, it is related to the degree of saturation and this, in turn, is related with the moisture content of the soil, which varies with the pluviometric ratios, following that, this research used a meteorological mini-station to monitor the climatological data in the period of one year and parallelly, during the same period, various profiles of the soil's moisture content were obtained. Furthermore, during this period, Dynamic Penetration Light (DPL) studies were realized, on the field, in order to verify the resistance variation of the soil's penetration in the curse of the year. For each metric profile of the soil, soil-water characteristic curves were obtained and in function of the soil's moisture content acquired during the research, complementary climatological information was obtained, due to this work, it was possible to recommend a maxim value of the matrix suction to be considered within a geothecnical project for the soil here studied.
34

Otimização de fundações estaqueadas

Lima, Bruno Salgado 12 March 2007 (has links)
xiv, 118 f. : il. / Submitted by Kathryn Cardim Araujo (kathryn.cardim@gmail.com) on 2009-12-17T14:04:07Z No. of bitstreams: 1 Dissert_Bruno Salgado Lima.pdf: 1205712 bytes, checksum: b0b83e45245c7011cc7564fc4a0eb31d (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2009-12-17T20:42:37Z (GMT) No. of bitstreams: 1 Dissert_Bruno Salgado Lima.pdf: 1205712 bytes, checksum: b0b83e45245c7011cc7564fc4a0eb31d (MD5) / Made available in DSpace on 2009-12-17T20:42:37Z (GMT). No. of bitstreams: 1 Dissert_Bruno Salgado Lima.pdf: 1205712 bytes, checksum: b0b83e45245c7011cc7564fc4a0eb31d (MD5) Previous issue date: 2007-03-12 / Nesta dissertação procurou-se unir dois campos do conhecimento. O primeiro deles é a utilização do radier estaqueado como conceito de fundação, pois a metodologia de cálculo praticada no mercado (grupo de estacas) despreza a capacidade da placa para suporte à carga e a redução de recalques e esforços, considerando o radier (ou bloco) apenas para coroamento do grupo de estacas. O segundo campo é sobre otimização nos projetos de engenharia, já bastante extensa em trabalhos e pesquisas com estrutras de pré-moldados de concreto, mas ainda recém chegada ao campo das fundações. Inicialmente, estudaram-se os métodos utilizados tanto para análise de fundações, quanto métodos para otimização de problemas discretos. A seguir, foram analisados diversos casos de fundação e o comportamento do programa de otimização observando sua sensibilidade comparando-se casos com variação de tipo de carregamento, tipo de solo, ou diâmetro da estaca. Por fim, analisou-se um caso particular de um radier estaqueado em Brasília, onde foram comparadas três análises: a análise convencional como grupo de estacas; uma análise na forma de otimização manual (baseada na experiência do profissional num processo tentativa-erro) e por último a análise realizada pelo programa de otimização. _______________________________________________________________________________ ABSTRACT / In this dissertation it was looked to join two fields of the knowledge. The first one of them is the use of piled raft as foundation concept, therefore the methodology of calculation practised in day-by-day (group of piles) disdains the capacity of the plate for support the load and the reduction of stress and efforts, considering radier (or block) only for linking of the group of props. The second field is about otimization in the projects of engineering, already sufficiently extensive in works and research in estrutras of prefabricated in concrete, but still just arrived at the field of the foundations. Initially, it was studied the methods used for analysis of foundations and methods for otimization of discrete problems. Later, diverse cases of foundation had been analyzed and the behavior of the otimization program, observing its sensitivity comparing itself cases with variation of type of load, type of soil, or diameter of the piles. Finally, a particular case of piled raft in Brasilia was analyzed, where three analyses had been compared: the conventional analysis as group of props; an analysis in the form of manual otimization (based in the experience of the professional in the traditional way to do in a trial error basis) and finally the analysis realized by the otimização program in this work.
35

Estudo experimental do comportamento de fundações escavadas em solos tropicais / Experimental study of the behavior of bored pile foundations founded in tropical soils

Anjos, Gérson Jacques Miranda dos 24 March 2006 (has links)
Tese (doutorado)-Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, Brasília, 2006. / Submitted by Mariana Fonseca Xavier Nunes (nanarteira@hotmail.com) on 2010-09-25T20:13:59Z No. of bitstreams: 1 2006-G+®rson Jacques Miranda dos Anjos.pdf: 7142307 bytes, checksum: 684573087215d3006183234ca06fadd4 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2010-10-14T11:36:44Z (GMT) No. of bitstreams: 1 2006-G+®rson Jacques Miranda dos Anjos.pdf: 7142307 bytes, checksum: 684573087215d3006183234ca06fadd4 (MD5) / Made available in DSpace on 2010-10-14T11:36:44Z (GMT). No. of bitstreams: 1 2006-G+®rson Jacques Miranda dos Anjos.pdf: 7142307 bytes, checksum: 684573087215d3006183234ca06fadd4 (MD5) / Neste trabalho, objetivou-se ampliar o entendimento a respeito da capacidade de suporte e da relação carga-deslocamento de fundações profundas tipicamente empregadas no D.F., a saber, estacas escavadas, tubulões e estacas do tipo hélice contínua. Assim, realizou-se um estudo experimental e numérico do comportamento dessas fundações. Usaram-se resultados de ensaios tipo SPT e CPT como forma de verificação das análises de capacidade de suporte propostas. Além disso, fizeram-se análises em estaca hélice contínua (isolada e em grupos) da capacidade de suporte por métodos que empregam o ensaio SPT. Utilizou-se da metodologia de Fleming (1992) na análise da relação carga-deslocamento das provas de carga. Essa metodologia, que adota funções hiperbólicas para representar a relação carga-deslocamento, tanto do fuste quanto da base, mostrou-se adequada, sobretudo na estimativa da carga de trabalho. Devido à sua simplicidade e fácil aplicação, sua utilização em projetos é, portanto, sugerida. Propôs-se ainda uma adaptação do método de Paikowsky para estimar a carga limite de fundações escavadas a partir de provas de cargas que não foram levadas à condição de ruptura. O método proposto baseia-se nas metodologias de Chin e Davisson, cujo valor da carga limite está associado a um certo valor de deslocamento. Observa-se que não se trata de um método de extrapolação da curva carga-deslocamento. Os resultados, em termos de carga e deslocamento, mostraram-se realistas e satisfatórios, em especial para os deslocamentos associados à carga limite. Avaliou-se também a influência da tensão residual nos resultados de provas de carga instrumentadas. Para esse fim, utilizou-se do software Unipile. Observou-se que negligenciar o efeito da tensão residual conduz a erros na interpretação das cargas em profundidade. Por exemplo, as cargas estimadas na base são menores, enquanto que as do fuste são maiores quando comparadas com a distribuição real obtidas de provas de carga vertical. Por fim, realizaram-se análises numéricas numa estaca escavada e num tubulão executados no Campo Experimental da UnB. Neste caso, utilizou-se tanto de funções de transferência de carga quanto dos softwares Geo4 (módulo Piles) e Plaxis 2D. Os resultados mostraram-se satisfatórios em particular na estimativa da carga de trabalho. _________________________________________________________________________________ ABSTRACT / The main goal of this work was to broaden the understanding about load capacity and loaddisplacement relation of deep foundations founded in the Federal District of Brazil, namely, bored piles, drilled shaft and continuous flight auger. Thus, an extensive experimental and numerical study of those types of foundations was carried out herein. Results of SPT and CPT in situ tests were used as a way to verify the proposed analysis of load capacity. Besides that, load capacity analyses of continuous flight auger, both isolated or in groups, were performed using methods which are based on SPT in situ tests. Flemings (1992) methodology was used to analyze the load-displacement relation of load tests. This methodology, that employs hyperbolic functions to represent the load-displacement relations on both shaft and base, allowed the establishment of realistic results, especially when assessing the load capacity. Due to simplicity and easy application, its usage in current projects is suggested. A method to estimate the limit load of bored foundations from prematurely finished load tests was proposed as well. The method is based on Chins and Davissons methods, whose value of limit load is associated to a value of displacement. It is important to note that the proposed method is not a load-displacement extrapolation curve. The results in terms of load and displacement were realist and satisfactory, particularly with respect to displacements associated to the limit load. The influence of residual stress in load test results was also assessed. The software Unipile was used to accomplish this objective. It was observed that, to neglect the effect of residual stress, leads to errors when interpreting results of load tests. For instance, loads on the base are smaller, while loads on the shaft are greater when compared to the real distribution obtained from compression axial tests. At last, numerical analyses of a bored pile and a drilled shaft performed on our Experimental site were also carried out. In this case, both load transference functions and the software Geo4 (module Piles) and Plaxis 2D were used. The results were effective, especially at estimating the working load.
36

Avaliação experimental de fundações estaqueadas em modelos 1g

Tavares, Marcus Vinicius Costa Ferreira 08 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-09-09T13:50:00Z No. of bitstreams: 1 2012_MarcusViniciusCostaFerreiraTavares.pdf: 12786548 bytes, checksum: 73022e03ab05f4e13af52ea88428c128 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-09-09T15:57:41Z (GMT) No. of bitstreams: 1 2012_MarcusViniciusCostaFerreiraTavares.pdf: 12786548 bytes, checksum: 73022e03ab05f4e13af52ea88428c128 (MD5) / Made available in DSpace on 2013-09-09T15:57:41Z (GMT). No. of bitstreams: 1 2012_MarcusViniciusCostaFerreiraTavares.pdf: 12786548 bytes, checksum: 73022e03ab05f4e13af52ea88428c128 (MD5) / A verticalização das cidades ocasionada pelo crescimento urbano, bem como a construção de estruturas de grande porte, gerou a procura de sistemas estruturais de fundação que suportassem os níveis de carregamento das obras atuais. O aprimoramento das metodologias construtivas viabilizou a execução de fundações estaqueadas. Entretanto, uma compreensão mais aprimorada sobre o comportamento desses sistemas leva os engenheiros a repensarem as hipóteses de transferência de cargas. A ideia do radier estaqueado (radier + estacas) surge como uma alternativa extremamente viável, em termos econômicos, em face da utilização de sistemas convencionais de estaqueamento. Diferenciando-se em relação aos agrupamentos convencionais de estacas, o radier estaqueado não despreza a parcela complementar de capacidade de carga proveniente do contato do bloco, ou radier, com o solo. De forma semelhante aos demais grupos de fundações profundas, as estacas funcionam como redutores de recalques, além de contribuir também para a capacidade de carga total do sistema. Buscando um melhor entendimento das fundações estaqueadas, lançou-se mão de uma modelagem reduzida simples como ferramenta para uma análise qualitativa das características do comportamento mecânico de um radier estaqueado sujeito a condições ideais. A comparação do comportamento das fundações estaqueadas proporcionará uma avaliação dos fatores de interação entre os elementos da fundação (radier e as estacas), bem como o comportamento carga-recalque destas. O material utilizado como solo trata-se de uma areia seca lançada num cilindro de modelagem reduzida 1g, com altura de 0,60 x 10-3 m e diâmetro de 1,15 x10-3 m compactada de modo a garantir um nível de compacidade adequado para instalação do modelo reduzido. O protótipo de fundação é composto por placas metálicas retangulares, que simulam os radiers, e tubos metálicos vazados, e cortados transversalmente, com altura de 2,12x10-1 m, e diâmetro externo de 1,28x10-2 m e diâmetro interno de 0,92 x10-2 m, que simulam as estacas. Os incrementos de carga no modelo reduzido são efetuados com a utilização de um macaco hidráulico instalado adequadamente no cilindro de modelagem reduzida. _______________________________________________________________________________________ ABSTRACT / The verticalization of cities caused by urban growth and the construction of larges structures generated the demand for the structural foundation that could withstand the loading levels of current works. The improvement of methodologies enabled the implementation of constructive piled foundations. However, a more refined understanding of the behavior of these systems leads engineers to rethink the assumptions of load transfer. The idea of piled raft (raft + piles) emerges as an extremely viable alternative in economic terms, due to the use of conventional piling. Differing slightly from the conventional grouping of piles, the raft piled does not neglect the complementary part of load capacity from the contact block, or raft, with the ground. Similar to other groups of deep foundations, the piles act as reducers of settlements, and also contribute to the total carrying capacity of the system. Seeking a better understanding of the piled foundations, this work will use a small and simple 1g modeling as a tool for a qualitative analysis of the characteristics of the mechanical behavior of a piled raft subjected to ideal conditions. The comparison of the behavior of piled foundations provide an assessment of the interaction effects between the elements of the foundation (raft and piles), and the behavior of these load-settlement. The material used as soil was a dry sand compacted in a cylinder mold modeling reduced at 1g condition with a height of 0,60 x 10-3 m and a diameter of 1,15 x10-3 m, so as to ensure an adequate degree of compactness for installation of the reduced model. The prototype of the foundation is composed of rectangular metal plates, which simulates the radiers, metal hollow pipes cut transversely, with a height of 2.12 x10-¹ m and outer diameter of 1.28 x10-2 m internal diameter of 0.92 x10-2 m, which simulate the piles. The increase in load on the scale model are performed using a hydraulic jack properly installed in the small scale system. The theoretical framework used in interpreting the results for the load-settlement behavior is subsidized by the study introduced by Poulos & Davis (1980) plus the simple method of load sharing between the raft and the piles proposed by Randolph (1994). The mechanisms of interaction in piled rafts adopted are those of Hain and Lee proposed in 1978.
37

Estudo do comportamento mecânico e numérico de grupo de estacas do tipo Alluvial Anker em solo poroso do Distrito Federal

Mendoza Bolaños, Cristhian Camilo 09 1900 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-12-03T13:17:55Z No. of bitstreams: 1 2013_CristhianCamiloMendozaBolanos.pdf: 146257921 bytes, checksum: d9481b733aba59c5d3f8f9c5a6da4999 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-02-03T11:31:10Z (GMT) No. of bitstreams: 1 2013_CristhianCamiloMendozaBolanos.pdf: 146257921 bytes, checksum: d9481b733aba59c5d3f8f9c5a6da4999 (MD5) / Made available in DSpace on 2014-02-03T11:31:10Z (GMT). No. of bitstreams: 1 2013_CristhianCamiloMendozaBolanos.pdf: 146257921 bytes, checksum: d9481b733aba59c5d3f8f9c5a6da4999 (MD5) / Este trabalho apresenta um estudo do comportamento mecânico de grupos de estacas e Radier Estaqueados com estacas Alluvial Anker na argila porosa do Distrito Federal. Como passo inicial, estudou-se o comportamento mecânico da argila porosa do Distrito Federal por meio de ensaios triaxiais. Das situações expostas, testou-se três modelos constitutivos que levam em conta a estrutura do solo (Elastoplásticos e hipoplástico) e concluiu-se qual é o modelo que melhor descreve o comportamento da argila. Por outro lado, avaliou-se o comportamento mecânico de grupos de estacas e Radier Estaqueados por meio de provas de carga estáticas no campo experimental da empresa Solotrat. Com os dados obtidos, realizaram-se simulações em elementos finitos (FEM) no programa Abaqus implementado o modelo escolhido para descrever o comportamento de argila do Distrito Federal. Como resultados, obtiveram-se a resistência última de grupos de estacas com e sem suporte da placa; os mecanismos de tensões e deslocamentos gerados no Radier Estaqueados; e a contribuição de carga gerada pelo Radier. Ademais, foram realizadas simulações considerando a variabilidade intrínseca do solo e como resultado obteve-se as percentagens de contribuição do Radier no grupo de estacas, o qual pode varia entre 2% e 25% do total da carga última, dependendo da variabilidade do solo. _______________________________________________________________________________________ ABSTRACT / This work presents a description of the mechanical behavior of pile groups and piled rafts with Alluvial Anker piles types installed in porous clays of the Federal District of Brazil. The initial stage of the study involve a series of triaxial tests carried out on porous clays to obtain help define its mechanical behavior. Three constitutive models that consider the soil structure (elastoplastics and hypoplastic) were evaluated to predict which one better described the observed clay behavior. Moreover, the mechanical behavior of the pile groups and piled raft were validated by means of static load tests performed in the experimental field of the Solotrat company. Using the obtained data, 3D finite element simulations (FEM) were performed using the software Abaqus. The chosen model was implemented to describe the behavior of the clay of the Federal District. The following data was obtained as a result: the ultimate load of pile groups with and without the addition of the raft, the generated stress and settlement mechanisms, and the contribution of the raft in the piled raft. Finally, simulations were performed considering the inherent variability of the soil. The result was obtained as the percentage contribution of the raft in the piled raft, which may fluctuate between 2% and 25% of the total ultimate load depending on these soil is variability.
38

Estados limites de fundações considerando a resposta da superestrutura / Limits states of foundations considering structure response

Camargo, Fabiana Ester de January 2002 (has links)
A superestrutura, suas fundações e o solo formam um sistema. É evidente, portanto, a necessidade de um estudo que englobe todo o sistema, estabelecendo qual a influência dos deslocamentos do solo na superestrutura. Toda fundação sofre deslocamentos verticais, horizontais ou rotacionais, conforme a solicitação a qual está submetida. Os deslocamentos, conforme sua magnitude, terão uma influência sobre a estrutura, que vai desde uma simples redistribuição de cargas até o colapso. O objetivo deste trabalho é analisar a influência dos deslocamentos das fundações em torres de linhas de transmissão de energia. A metodologia adotada foi analisar as torres com apoios indeslocáveis (hipótese usual) e depois substituí-los por apoios flexíveis para verificar o efeito dos deslocamentos das fundações na distribuição das solicitações nas barras das torres. Este trabalho tem, adicionalmente, a intenção de contribuir aos grupos de estruturas e fundações, WG22-08 e WG22-07 da CIGRÉ em âmbito internacional, de forma articulada e coordenada. Assim sendo, este trabalho também objetiva preliminarmente avaliar algumas implicações de procedimentos usuais de análise e projeto, interrelacionados ao objetivo central, incluindo incertezas na modelagem para a previsão do comportamento estrutural sob carregamentos externos e deslocamentos das fundações. Com base nos resultados das aplicações estudadas, propõe-se um procedimento de caráter preliminar, para obtenção de coeficientes a serem aplicados no projeto das fundações e da torre. Estes coeficientes teriam as funções de limitar o deslocamento das fundações sob ação do carregamento máximo e dimensionar a torre de maneira que acréscimos de solicitações nas barras devido ao deslocamento limite possam ser absorvidos pela estrutura. / The structure and its foundations have to be regarded as a system. Therefore, it is clear the importance of studies leading to take into account the influence of foundation displacements on the structure performance. Any foundation undergoes displacements when is subjected to loading. Depending of the magnitude of such displacements, their influence may vary from a simple balance of member forces up to the structure or component collapse. The objective of this dissertation is to analyse the influence of displacements on structures, and in particular on transmission line tower for electrical energy. The approach adopted in this work was to initially consider the tower on fixed foundations and, afterwards, to replace these conditions by others allowing displacements and verify the influence on the member force distribution. In addition, this dissertation also aims to contribute to the Projects of CIGRÉ WG22-08, as well as of WG22-07, "Transmission Line Structures” and “Transmission Line Foundations", respectively. These Projects have a wide range of objectives which may be summarised by "to reach a better understanding of the capability of standard design models to predict the actual behaviour and the actual performance of structures and foundations of transmission lines". Based on the results of analyses carried out, a preliminary approach to establish a "design coefficient" for the combined design of tower and foundation is proposed. This coefficient would establish allowable foundation displacements, as well as the ultimate bar strength, in a such way to obtain a co-ordinated design of the system "structurefoundation".
39

Estudo do ensaio SPT-T e sua aplicação na prática de engenharia de fundações

Peixoto, Anna Silvia Palcheco, 1965- 29 July 2018 (has links)
Orientador: David de Carvalho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-29T05:23:33Z (GMT). No. of bitstreams: 1 Peixoto_AnnaSilviaPalcheco_D.pdf: 8297011 bytes, checksum: 9b545876060623953747f6b523b341d8 (MD5) Previous issue date: 2001 / Doutorado
40

Análise do comportamento de edifícios apoiados em fundação direta no bairro da Ponta da Praia na cidade de Santos. / Behavior analysis of buildings supported by shallow footing in the neighborhood Ponta da Praia in the city of Santos.

Marianna Silva Dias 18 May 2010 (has links)
A pesquisa aborda problemas de recalques que vem ocorrendo na Cidade de Santos desde o início dos anos 40, devido à implantação de edifícios sob fundação direta. O trabalho destaca o Bairro da Ponta da Praia, onde os recalques ocorridos, principalmente os diferencias, foram bem menores que no restante da orla, e a região entre os canais três e seis, denominado pela autora Faixa Crítica, onde estão concentrados diversos edifícios inclinados ao longo da orla. Foi feita uma revisão bibliográfica envolvendo aspectos históricos, geológicos e geotécnicos sobre a cidade de Santos e os principais fatores que a tornaram tão conhecida pelos edifícios tortos ao longo de sua orla. Nessa revisão, apresentaram-se dados sobre o subsolo de Santos, no contexto mais geral dos solos, a Baixada Santista. Foram reapresentados dados de alguns edifícios bastante recalcados e conhecidos na cidade e analisados métodos existentes para estabilização de recalques; alguns casos de aplicação foram relatados. Os estudos foram baseados em uma grande quantidade de sondagens de simples reconhecimento coletadas na cidade; alguns ensaios do cone, CPT e CPTU, também foram analisados. Foi feita uma comparação entre as duas regiões Ponta da Praia e Faixa Crítica, mostrando as diferenças nas espessuras e nas propriedades geotécnicas das camadas de areia superficial. Foram feitos também cálculos para a previsão de recalques no bairro da Ponta da Praia e na Faixa Crítica, levando-se em conta os mecanismos de sobreadensamento das argilas da Baixada Santista e diferenças nas espessuras da camada de areia superficial. Com a análise das sondagens coletadas foi possível responder alguns questionamentos sobre o perfil geotécnico da Orla de Santos, traçar o perfil geotécnico da orla do bairro da Ponta da Praia e traçar seções no sentido transversal à orla, (praia-centro). / The research concerns settlement issues occurring in the city of Santos since the 40s because of the building construction under shallow foundation. The work emphasizes the neighborhood called Ponta da Praia where the settlements mainly the differentials, have been slighter than the rest of the seashore, and the region between the channels three and six, named by the author the Critical Strip several inclined buildings are concentrated along the seashore. A bibliographic revision has been made involving historical, geological and geotechnical aspects about the city of Santos and the mainly facts which became the city well-known due to the inclined buildings along the seashore. The revision presented specific geotechnical data about the Santos subsoil, in the general context the Santos Coastal Plain, named Baixada Santista. Settlement data of some inclined buildings where also presented and current plumbing methods were evaluated and some application cases were reported. The studies were based in a large amount of borings (SPT) executed in the city; and a couple of CPT and CPTU were analyzed. The differences between Ponta da Praia and the Critical Strip were pointed out related to the upper sand layer thickness as well as its geotechnical properties. Also computations were made for the evaluation of settlement in the neighborhood Ponta da Praia an in the Critical Strip taking into account the known clay overconsolidation mechanisms in the Baixada Santista and differences in upper sand layer thickness. With the boring analyses it was possible to answer some questions about the existing geotechnical section of the neighborhood Ponta da Praia and to sketch cross-sections transverse to the seashore (beach city center).

Page generated in 0.0384 seconds