• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • Tagged with
  • 9
  • 9
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Thesis_HC_04242023.pdf

Haichuan Cao (15347563) 26 April 2023 (has links)
<p>  Present WIMP Dark Matter search strategies are mainly focused on possible direct detection through elastic or inelastic scatterings on atomic nuclei, or with electrons. This approach<br> becomes insensitive to M(DM) < 10 GeV. Indirect DM detection refers to the search for DM-DM or DM-M annihilation, decay debris from DM particles, or other particle production,<br> resulting in detectable species. </p> <p><br>    New physics processes, initiated by cosmic ray or dark matter interactions may be observable in underground indirect search experiments by excess high multiplicity neutron<br> production in nuclear targets. Even for M(DM) < 10 GeV, DM-M interaction is capable of<br> producing large signals, >200 neutrons if the energy is deposited in a Pb target.</p> <p><br></p> <p>  The NMDS-II detector, located at an underground laboratory within the Pyhasälmi<br> complex metal mine in central Finland, collated data for 6504 ± 1 hours at 583 m.w.e.<br> and for 1440 ± 1 hours at 1166 m.w.e.. The detector system consists of a 30 cm cube<br> Pb-target surrounded by 60 He-3 proportional tubes and a two layer Geiger Counter muon<br> detection system. The lead target is used to interact with potential dark matter particles, and<br> neutron numbers are measured with He-3 tubes. The neutron event multiplicity production is<br> compared to Geant4 simulations, starting with the well measured absolute muon momentum<br> and angular distribution flux rate at sea level, then propagating the muon flux through rock<br> while preserving the momentum-angular correlation to a depth 4m above the the detector at<br> the two depth locations. The muon flux modeling is compared to the uncorrelated Miyake<br> model at each depth as verification of the muon propagation simulation. Finally, the Geant4<br> fully simulates the passage of the muon and its induced showers through a model universe<br> 10000 m^2 x 12 m depth, and the simulated response of the detector to the calculated muon<br> flux, is compared with the data. <br>  </p> <p>  The Geant4 prediction and the observed data neutron event multiplicity distributions<br> have matching power law shapes, k × n^(-p), and do not have exponential shapes. For the<br> data collected at 583 m.w.e., p=2.36±0.10 with χ2/DoF = 0.76 and for the simulation<br> p=2.34±0.01 with χ2/DoF = 1.05. At 1166 m.w.e., p=2.29±0.007 for the simulation with  χ2/DoF = 1.16. And for the data the collection with only 6 detected events above multiplicity 5, yields p=2.50 ± 0.35 predicted by the Maximum Likelihood Estimatation method. </p> <p><br></p> <p>  The DM acceptance as a function of mass is found using a proton-Pb spallation model.<br> The dark matter mass is assumed to be equal to the proton kinetic energy and to interact<br> uniformly over the volume of the lead target. The number of excess events is found to be<br> -6.1 ± 5.1, that is no excess events are observed. The upper limit with 90% confidence<br> level is then found assuming 2.3 events. The Poisson estimation then yielding search limits<br> 1.1×10^(-44) cm^(-2) for 10 GeV deposited energy, 1.9×10^(-45) cm^(-2) at 1 GeV and 3.0×10^(-45) cm^(-2) for 500 MeV deposited energy and no acceptance at 100 MeV.<br> </p> <p>    An indirect dark matter search was conducted based on DM-M interactions depositing<br> energy in a Pb-target allowing DM masses to be probed in a region 100 MeV < M(DM) <<br> 10 GeV not accessible to direct dark matter searches. Limits are placed on DM-M energy<br> deposition independent of the DM-M interaction. <br>  <br>  <br>  <br>  </p>
2

Mesure de la dose physique par lms radiochromiques et simulation Monte Carlo pour l'hadronthérapie / Dose measurement using radiochromic lms and Monte Carlo simulation for hadrontherapy

Zahra, Nabil 25 June 2010 (has links)
En raison des forts gradients de dose générés par les interactions des particules avec la matière, les traitements par hadronthérapie nécessitent un contrôle très précis de la dose délivrée au patient. Les codes Monte Carlo représentent des outils indispensables dans la validation des systèmes de planification de traitement utilisé en clinique. Nous nous intéressons dans cette thèse au calcul de la dose physique à l'aide des simulations Monte Carlo Geant4/Gate. Nous étudions l'ajustement de plusieurs paramètres qui peuvent influencer la précision du calcul de dose requise en clinique (2%, 2mm) pour un faisceau d'ions carbone de 300 MeV/u dans l'eau. Ces paramètres sont : le seuil de production des particules secondaires et la taille maximale d'un segment de la trace de particule. Les critères de tolérance sur la valeur et la localisation de la dose sont fixés de manière à avoir le meilleur compromis en termes de distribution spatiale et de temps de calcul. Nous proposons ici des paramètres permettant d'atteindre ces critères de précision. Dans la deuxième partie du travail, nous étudions la réponse des films radiochromiques MDv2-55 pour le contrôle qualité des faisceaux d'ions carbone et protons. Nous avons en particulier observé et étudié l'effet de saturation de ces films dosimétriques pour les irradiations à TEL élevés (≥ 20 KeV/µm) dans des milieux homogènes et hétérogènes. Cet effet est dû à la forte densité d'ionisation autour de la trace de particule. Nous avons proposé et développé un modèle appelé « RADIS RAdiochromic films Dosimetry for Ions using Simulations » qui permet de prédire la réponse de ces films avec la prise en compte de cet effet de saturation. Ce modèle est basé sur la réponse des films en photons et la saturation des films à des dépôts d'énergies linéïques élevés calculée par Monte Carlo. Plusieurs types de faisceaux ont été étudiés : ions carbone, protons et photons à différentes énergies. Ces expérimentations ont été menées au Grand Accélérateur National d'Ions Lourds (GANIL), au Centre de protonthérapie d'Orsay (CPO), au Centre A. Lacassagne (CAL) et au Centre Léon Bérard (CLB). A l'aide du modèle, nous pouvons ainsi reproduire la densité optique des films le long du profil de Bragg pour tous les faisceaux avec une précision meilleure que 2%. / Because of the increase in dose at the end of the range of ions, dose delivery during patient treatment with hadrontherapy should be controlled with high precision. Monte Carlo codes are now considered mandatory for validation of clinical treatment planing and as a new tool for dosimetry of ion beams. In this work, we aimed to calculate the absorbed dose using Monte Carlo simulation Geant4/Gate. The ejffect on the dose calculation accuracy of dierent Geant4 parameters has been studied for mono-energetic carbon ion beams of 300 MeV/u in water. The parameters are : the production threshold of secandary particules and the maximum step limiter of the particle track. Tolerated criterion were choosen to meet the precision required in radiotherapy (2%, 2mm) and to obtain the best compromise on dose distribution and computational time.We propose here the values of parameters in order to satisfy the precision required. In the second part of this work, we will study the response of radiochromic lms MD-v2-55 for quality control in proton and carbon ion beams. We have particularly observed and studie the quenching effect of dosimetric lms for high LET (20 KeV/m) irradiations in homogeneous and heterogeneous medium. This eject is due to the high ionization density around the track of the particule. We have developped a method to predict the response of radiochromic lms taking into account the saturation effect. This model is called the RADIS model forRAdiochromic films. Dosimetry for Ions using Simulations". It is based on the response of lms under photon irradiations and the saturation of lms due to high linear energy deposit calculated by Monte Carlo. Four beams were used in this study and aimed to validate the model for hadrontherapy applications : carbon ions, protons and photons at different energies. Experiments were performed at Grand Accélérateur National d'Ions Lourds (GANIL), Proton therpay center of Orsay (CPO), A. Lacassagne proton center (CAL) and Leon Berard cancer center (CLB). The model showed very good agreement between the measured and calculated optical density with an error less than 2%.
3

Search for dark matter with EDELWEISS-III excluding background from muon-induced neutrons / Recherche de matière noire avec l'expérience EDELWEISS-III excluant le bruit de fond neutron induit par les muons

Kéfélian, Cécile 05 February 2016 (has links)
Le but de l'expérience EDELWEISS est la détection directe de matière noire sousforme de WIMPs, par l'étude de leur diffusion élastique sur les noyaux de germanium des détecteurs bolomètriques. Le plus problématique des bruits de fond provient des neutrons pouvant mimer l'interaction d'un WIMP dans un détecteur. Ces neutrons sont notamment produits par les rares muons cosmiques de haute énergie qui atteignent le laboratoire souterrain malgré les 4800 m w.e. de roche. Les muons résiduels sont détectés par un système veto de 46 modules de scintillateur plastique entourant l'expérience, qui permet de rejeter la plupart du bruit de fond associé. La détermination précise du bruit de fond neutron résiduel induit par ces muons dans EDELWEISS-III, essentielle pour l'identification des WIMPs, est le but de cette thèse. Le taux de bruit de fond dépend de la géométrie de l'expérience ainsi que des matériaux utilisés, qui ont subi d'importantes modifications depuis EDELWEISS-II. Des simulations GEANT4 du passage des muons dans la nouvelle géométrie ont été réalisées afin d'extraire le taux d'événements induits par les muons dans les bolomètres. Ce taux est en bon accord avec le taux mesuré extrait des données du Run308. En parallèle, une limite inférieure sur l'efficacité du veto muon a été extraite à partir des données bolomètres. Une nouvelle méthode basée sur l'utilisation d'une source d'AmBe a été développée afin d'extraire l'efficacité de chaque module de la simulation. À partir de ces résultats, il a été montré que le bruit de fond attendu est négligeable pour la recherche de WIMPs avec les données du Run308 et ne limitera pas la sensibilité future d'EDELWEISS-III / The aim of the EDELWEISS-III experiment is to detect the elastic scattering of WIMPs from the galactic dark matter halo on germanium bolometers. The most problematic background arises from neutrons, which can mimic a WIMP interaction in a detector. Neutrons are notably induced by high energy cosmic ray muons reaching the underground laboratory despite the 4800 m w.e. of rock overburdened. Remaining muons are tagged using an active muon-veto system of 46 plastic scintillator modules surrounding the experiment, which allows to reject most of the associated background. The goal of this thesis was to give a precise estimation of the irreducible muon-induced neutron background, needed to identify a potential WIMP signal. The expected background depends on the geometry of the experiment as well as on the used materials, both strongly modified since EDELWEISS-II. Geant4-based simulations of muons through the modified geometry were performed to derive the rate of events induced by muons in the bolometer array. This rate has been shown to be in good agreement with the measured one extracted from the Run308 data. In parallel, a lower limit on the muon-veto efficiency was derived using bolometer data only. A new method based on an AmBe source was developed to extract precisely the detection efficiency of individual modules from the simulation. From these results, it was shown that the expected background is negligible for the WIMP search analyses performed with the Run308 data and won't limit the future sensitivity of the EDELWEISS-III experiment
4

Etude de faisabilité d'un détecteur dédié à la discrimination bêta/gamma / Study of the feasibility of a detector dedicated to the beta/gamma discrimination

Luo, Yiyan 04 December 2018 (has links)
A des fins de propreté radiologique, les exploitants nucléaires doivent évaluer l'activité surfacique résiduelle, telle que la contamination bêta. Pour cela, les contaminamètres sont essentiels. Dans ce cadre, EDF R&D a proposé un projet de recherche visant à étudier la faisabilité d’un contaminamètre innovant permettant de détecter l’activité surfacique bêta in situ, alors qu’elle est actuellement mesurée ex-situ.L'objectif principal de ce travail est de détecter une contamination bêta surfacique de 0,4 Bq/cm^2 dans un environnement gamma élevé, jusqu'à 100 µSv/h. Cela exige un détecteur ayant une performance de discrimination bêta/gamma élevée. Plusieurs technologies basées sur un scintillateur et/ou un détecteur à gaz ont été étudiées. Des simulations Geant4 ont été effectuées pour optimiser la configuration des technologies retenues (géométrie, matériaux, etc.). Suite à ces simulations, deux prototypes, de type Phoswich, optimisés ont été fabriqués et testés à l’aide de sources bêta et gamma au laboratoire ( LPC Caen). En outre, deux campagnes d’essai ont été menées dans une centrale nucléaire (CNPE de Chinon) afin d'évaluer les performances des prototypes développés dans un bruit de fond gamma réaliste. Les simulations Geant4 et les tests sont discutés dans cette thèse. / For radiological cleanliness purpose, nuclear operators have to assess surface residual activity such as beta contamination. To this aim, contamination monitors are essential. In this context, EDF R&D proposed a research project in order to study the feasibility of an innovative contamination monitor to detect beta surface activity in situ which is until now performed ex situ. The main objective is to detect a 0.4 Bq/cm^2 beta surface contamination in a high gamma background up to 100 μSv/h. This demands the detector to have a high beta/gamma discrimination performance. Several technologies based on scintillator and/or gas filled detector have been investigated. Geant4 simulations have been carried out to optimise the configuration of the chosen detector such as geometry, materials, etc. Two simulation-optimised prototypes based on Phoswich detectors have been developed and tested with beta and gamma sources in a laboratory framework (LPC Caen). Furthermore, two experimental campaigns have been conducted in a nuclear power plant (NPP of Chinon) in order to evaluate the performance of the developed prototypes in a realistic gamma background environment. The Geant4 simulations and the experimental work are discussed in this thesis.
5

Implémentation de la répartition de charge et du mode TOT pour la simulation d’un détecteur Timepix à pixels

Dallaire, Frédérick 03 1900 (has links)
Les détecteurs à pixels Medipix ont été développés par la collaboration Medipix et permettent de faire de l'imagerie en temps réel. Leur surface active de près de $2\cm^2$ est divisée en 65536~pixels de $55\times 55\um^2$ chacun. Seize de ces détecteurs, les Medipix2, sont installés dans l'expérience ATLAS au CERN afin de mesurer en temps réel les champs de radiation produits par les collisions de hadrons au LHC. Ils seront prochainement remplacés par des Timepix, la plus récente version de ces détecteurs, qui permettent de mesurer directement l'énergie déposée dans chaque pixel en mode \textit{time-over-threshold} (TOT) lors du passage d'une particule dans le semi-conducteur. En vue d'améliorer l'analyse des données recueillies avec ces détecteurs Timepix dans ATLAS, un projet de simulation Geant4 a été amorcé par John Id\'rraga à l'Université de Montréal. Dans le cadre de l'expérience ATLAS, cette simulation pourra être utilisée conjointement avec Athena, le programme d'analyse d'ATLAS, et la simulation complète du détecteur ATLAS. Sous l'effet de leur propre répulsion, les porteurs de charge créés dans le semi-conducteur sont diffusés vers les pixels adjacents causant un dépôt d'énergie dans plusieurs pixels sous l'effet du partage de charges. Un modèle effectif de cette diffusion latérale a été développé pour reproduire ce phénomène sans résoudre d'équation différentielle de transport de charge. Ce modèle, ainsi que le mode TOT du Timepix, qui permet de mesurer l'énergie déposée dans le détecteur, ont été inclus dans la simulation afin de reproduire adéquatement les traces laissées par les particules dans le semi-conducteur. On a d'abord étalonné le détecteur pixel par pixel à l'aide d'une source de $\Am$ et de $\Ba$. Ensuite, on a validé la simulation à l'aide de mesures d'interactions de protons et de particules $\alpha$ produits au générateur Tandem van de Graaff du Laboratoire René-J.-A.-Lévesque de l'Université de Montréal. / The pixelated Medipix detectors have been developed by the Medipix Collaboration to perform real-time imaging. The semiconducting chip is divided into 65536 pixels of $55\times 55\um^2$ for a total active area of nearly $2\cm^2$. Because of their sensitivity to all kinds of particles, sixteen Medipix2 detectors (ATLAS-MPX) have been placed in the ATLAS detector and its cavern to measure for the radiation produced by the head-on proton collisions produced at the LHC. At the next ATLAS upgrade, the ATLAS-MPX network will be extended to include the Timepix detectors, the latest version that allows one to measure the total energy deposited in the semiconductor. To improve data analysis, a Geant4 simulation project of a Timepix detector was initiated by John Id\'arraga at the Université de Montréal. In the framework of the ATLAS experiment, this simulation could be used with Athena, the ATLAS analysis software, and the full ATLAS simulation. Due to their repulsivity, the charge carriers created by an incoming particle in the pixelated detector are spread over the surrounding pixels causing a charge sharing effect. An effective model has been developed to reproduce this effect without resolving the charge drift's differential equation. This model and the \textit{time-over-threshold} mode of the Timepix have been included in the simulation to reproduce the tracks left by the striking particles. First, one had to individually calibrate each pixel of the device with $\Am$ and $\Ba$ sources. The simulation's validation has been performed with low energy protons and $\alpha$ particles delivered by the van de Graaff Tandem at the Laboratoire René-J.-A.-Lévesque of the Université de Montréal.
6

A detector for charged particle identification in the forward region of SuperB / Un détecteur pour l’identification des particules chargées dans la région avant de SuperB

Burmistrov, Leonid 09 December 2011 (has links)
Dans cette thèse nous présentons la conception, l'étude des performances et les premiers tests, effectues au Cosmic Muon Telescope situe au SLAC, d'un nouveau détecteur d'identification des particules émises dans la région ''avant'' du détecteur SuperB.Ce détecteur est base une technique de temps de vol (TOF). Pour identifier les particules avec une impulsion jusqu'à 3GeV/c et une distance de vol de l'ordre de deux mètres nous avons besoin d'un détecteur TOF capable de mesurer le temps avec une précision typique de 30 ps. Pour atteindre cet objectif nous avons conçu un composant pour lequel le passage d'une particule chargée produit de la lumière Cherenkov dans un ''fused silica'' (quartz) radiator qui est ensuite détectée par des photodétecteurs tres rapides et une électronique rapide dédiée. Nous l'appelons détecteur DIRC-like TOF.Les photodétecteurs HAMAMATSU SL-10 MCP-PMT ont été caractérises sur faisceau de test au LAL et la résolution en temps d'environ 37 ps a été mesurée. La nouvelle électronique 16-canaux USB WaveCatcher développée au LAL(CNRS/IN2P3) et CEA/IRFU montre un jitter de moins de 10 ps. La géometrie du détecteur a quartz a été étudiée avec une attention particulière a l'aide d'une simulation Geant4. Celle-ci montre que la meilleure géométrie permet d'atteindre une résolution en temps d'environ 90 ps par photoélectron avec au moins 10 photoélectrons détectés, donnant en moyenne la résolution totale désirée de 30 ps.Nous avons construit un prototype d'un tel composant, utilisant les barres de quartz utilisées pour l'expérience Babar et nous l'avons installe dans le Cosmic Ray Telescope au SLAC. Une résolution en temps d'environ 70~ps par photoélectron a été obtenue, en accord avec la simulation.Cette preuve de principe a convaincu la Collaboration SuperB d'adopter un tel composant comme solution de base pour l'identification des particules émises vers l'avant dans SuperB. Le point délicat, encore ouvert, est celui de la résistance de ce détecteur aux bruits de fond de la machine.Dans cette thèse nous présentons aussi les études préliminaires de différents types de bruit de fond et leur effet sur les performances du détecteur DIRC-like TOF. Le processus Bhabha radiatif est de loin la source dominante de bruit de fond. Le taux de photoélectrons de bruit de fond principalement du aux gammas d'énergie d'environ 1.4 MeV est estimée a ~480 kHz/cm^2 ce qui correspond a 2 C/cm^2 de charge d'anode integrée sur 5 ans. Le flux de neutrons traversant l'électronique de front end du détecteur DIRC-like TOF est estimée a ~10^11/cm^2/year. Ces résultats préliminaires sont rassurants. / In this thesis, we present the conception, the performances studies and the first tests in the Cosmic Muon Telescope situated at SLAC of a new detector for the particle identification in the forward region of the SuperB detector.This detector is based on time-of-flight (TOF) technique. To identify the particles with momentum up to 3 GeV/c and flight base around two meters we need a TOF detector able to measure the time with a precision of about 30 ps. To achieve this goal we have conceived a device producing Cherenkov light in a fused silica (quartz) radiator, by a charged particle, which then detected with very fast photodetectors and dedicated ultrafast electronics. We call it, the DIRC-like TOF detector.For what concern the photodetectors, the HAMAMATSU SL-10 MCP-PMT has been characterized at LAL test bunch and the time resolution of about 37 ps has been measured. The new 16-channel USB WaveCatcher electronics developed by LAL (CNRS/IN2P3) and CEA/IRFU has shown to have a jitter of less than 10 ps. The geometry of the quartz detector has been then carefully studied with Geant4 simulation. Which shows that the best detector geometry allow to reach the time resolution of about 90 ps per photoelectron with at least 10 photoelectrons detected, giving in average the desired 30 ps total time resolution.We have constructed a prototype of such device, using the quartz bars available from the Babar experiment, and we have installed it, in the SLAC Cosmic Ray Telescope. A time resolution of about 70 ps per photoelectron was obtained, in agreement with simulation.This proof-of-principle has convinced the SuperB Collaboration to adopt such a device as the baseline for the SuperB particle identification detector in the forward region. The delicate point which is still opened is the resistance of this detector to the machine background.In this thesis we also present preliminary studies of different types of background and their effect on the performances of the DIRC-like TOF detector. Radiative Bhabha process is by far the dominant source of background. The rate of the background photoelectrons caused mainly by the gammas with energy around 1.4 MeV is estimated to be ~480 kHz/cm^2 which corresponds to 2 C/cm^2 of integrated anode charge in 5 years. The neutron flux thought the DIRC-like TOF front end electronics is ~10^11/cm^2/year. These preliminary results are reassuring.
7

Implémentation de la répartition de charge et du mode TOT pour la simulation d’un détecteur Timepix à pixels

Dallaire, Frédérick 03 1900 (has links)
Les détecteurs à pixels Medipix ont été développés par la collaboration Medipix et permettent de faire de l'imagerie en temps réel. Leur surface active de près de $2\cm^2$ est divisée en 65536~pixels de $55\times 55\um^2$ chacun. Seize de ces détecteurs, les Medipix2, sont installés dans l'expérience ATLAS au CERN afin de mesurer en temps réel les champs de radiation produits par les collisions de hadrons au LHC. Ils seront prochainement remplacés par des Timepix, la plus récente version de ces détecteurs, qui permettent de mesurer directement l'énergie déposée dans chaque pixel en mode \textit{time-over-threshold} (TOT) lors du passage d'une particule dans le semi-conducteur. En vue d'améliorer l'analyse des données recueillies avec ces détecteurs Timepix dans ATLAS, un projet de simulation Geant4 a été amorcé par John Id\'rraga à l'Université de Montréal. Dans le cadre de l'expérience ATLAS, cette simulation pourra être utilisée conjointement avec Athena, le programme d'analyse d'ATLAS, et la simulation complète du détecteur ATLAS. Sous l'effet de leur propre répulsion, les porteurs de charge créés dans le semi-conducteur sont diffusés vers les pixels adjacents causant un dépôt d'énergie dans plusieurs pixels sous l'effet du partage de charges. Un modèle effectif de cette diffusion latérale a été développé pour reproduire ce phénomène sans résoudre d'équation différentielle de transport de charge. Ce modèle, ainsi que le mode TOT du Timepix, qui permet de mesurer l'énergie déposée dans le détecteur, ont été inclus dans la simulation afin de reproduire adéquatement les traces laissées par les particules dans le semi-conducteur. On a d'abord étalonné le détecteur pixel par pixel à l'aide d'une source de $\Am$ et de $\Ba$. Ensuite, on a validé la simulation à l'aide de mesures d'interactions de protons et de particules $\alpha$ produits au générateur Tandem van de Graaff du Laboratoire René-J.-A.-Lévesque de l'Université de Montréal. / The pixelated Medipix detectors have been developed by the Medipix Collaboration to perform real-time imaging. The semiconducting chip is divided into 65536 pixels of $55\times 55\um^2$ for a total active area of nearly $2\cm^2$. Because of their sensitivity to all kinds of particles, sixteen Medipix2 detectors (ATLAS-MPX) have been placed in the ATLAS detector and its cavern to measure for the radiation produced by the head-on proton collisions produced at the LHC. At the next ATLAS upgrade, the ATLAS-MPX network will be extended to include the Timepix detectors, the latest version that allows one to measure the total energy deposited in the semiconductor. To improve data analysis, a Geant4 simulation project of a Timepix detector was initiated by John Id\'arraga at the Université de Montréal. In the framework of the ATLAS experiment, this simulation could be used with Athena, the ATLAS analysis software, and the full ATLAS simulation. Due to their repulsivity, the charge carriers created by an incoming particle in the pixelated detector are spread over the surrounding pixels causing a charge sharing effect. An effective model has been developed to reproduce this effect without resolving the charge drift's differential equation. This model and the \textit{time-over-threshold} mode of the Timepix have been included in the simulation to reproduce the tracks left by the striking particles. First, one had to individually calibrate each pixel of the device with $\Am$ and $\Ba$ sources. The simulation's validation has been performed with low energy protons and $\alpha$ particles delivered by the van de Graaff Tandem at the Laboratoire René-J.-A.-Lévesque of the Université de Montréal.
8

Photon elastic scattering background events in the SuperCDMS SNOLAB experiment

Hassan, Noah 10 1900 (has links)
Alors que la nouvelle génération de détecteurs directs de matière sombre est en cours de construction, dans l’espoir de trouver de la matière sombre avec une masse inférieure au GeV, il est important de comprendre comment le rayonnement naturel peut produire un fond d’interactions à faible énergie. Cette thèse s’intéressera à la simulation de la diffusion élastique des rayons γ, une source possible de fonds pour les détecteurs de matière sombre sub-GeV. La simulation utilise le logiciel SuperSim basé sur Geant4 afin de modéliser l’expérience SuperCDMS SNOLAB. Une version modifiée du G4JAEAElasticScatteringModel appelée CDMSJAEAElasticScatteringModel a été mise en oeuvre dans SuperSim afin de simuler les mécanismes de diffusion de photon élastiques Rayleigh, nucléaire Thomson et Delbrück. Le CDMSJAEAElasticScatteringModel ajoute la possibilité pour les particules γ de déposer de l’énergie après avoir été diffusées élastiquement. La validité de ces deux modèles a été vérifiée et des erreurs dans le logicielle ont été rencontrées dans leur traitement des distributions d’angle de diffusion des photons qui déterminent les spectres d’énergie déposée. Les sections efficaces totales sont en accord avec la documentation et d’autres sources. Malgré les erreurs logicielles, la simulation définit une limite inférieure sur le taux de diffusion élastique des rayons γ de ∼ 0,01 et ∼ 0,035 photon diffusé élastiquement par kg par an pour les détecteurs SuperCDMS SNOLAB au germanium et au silicium, respectivement. Ces limites inférieures sont définies à l’aide d’une coupure d’énergie de recul de 1 eV. Cela fait de la diffusion élastique des rayons γ une source importante de bruit de fond pour détecteurs SuperCDMS proposés avec des capacités de discrimination ER/NR à des énergies de recul à l’échelle eV. / While the new generation of direct dark matter detectors are being built in the hopes of finding sub-GeV dark matter, it is important to understand how natural radiation can produce a background of low-energy interactions. This thesis will analyze simulating γ-ray elastic scattering, a possible source of background for sub-GeV dark matter detectors. The simulation uses Geant4-based SuperSim software in order to model the SuperCDMS SNOLAB experiment. A modified version of the G4JAEAElasticScatteringModel called CDMSJAEAElasticScatteringModel was implemented into SuperSim in order to simulate the Rayleigh, nuclear Thomson and Delbrück γ-ray elastic scattering mechanisms. The CDMSJAEAElasticScatteringModel adds the ability for the γ particles to deposit energy after being elastically scattered. The validity of both these models was checked, and errors were encountered in their treatment of photon scattering angle distributions which determine the deposited energy spectra. The total cross sections are consistent with the documentation and other sources. Despite the bug, the simulation does set a lower bound on the γ-ray elastic scattering rate of ∼ 0.01 and ∼ 0.035 elastically scattered photon per kg per year for germanium and silicon SuperCDMS SNOLAB detectors, respectively. These lower bounds are set using a 1 eV recoil energy cutoff. In conclusion, γ-ray elastic scattering a significant source of background for proposed SuperCDMS detectors with ER/NR discrimination capabilities at eV-scale recoil energies.
9

Deeply Virtual Compton Scattering off Helium-4 / La diffusion Compton Profondément Virtuelle sur l'Hélium-4

Hattawy, Mohammad 14 September 2015 (has links)
Les Distributions de Partons Généralisées (GPDs) sont des fonctions de structure riches qui contiennent des informations sur les corrélations de quark/ anti-quark, et sur les corrélations entre l'impulsion longitudinale et la position transversale des partons. Ces GPDs sont accessibles via des réactions exclusives durs tels que la Diffusion Compton Profondément Virtuelle (DVCS pour Deeply Virtual Compton Scattering), à savoir la leptoproduction d'un photon réel où le photon est émis par la cible. La DVCS nucléaire ouvre une nouvelle voie pour explorer la nature des modifications moyennes des hadrons dans le milieu nucléaire. Dans ce travail, nous présentons la première mesure exclusive du processus DVCS sur l'hélium-4 avec un faisceau d'électrons polarisés longitudinalement de 6 GeV et le détecteur CLAS dans le Hall B au Jefferson Lab, États-Unis. L'hélium-4 est d'un intérêt particulier il n'a qu'une seul GPD, en raison de son spin 0. Le but de cette étude est de comprendre les modifications nucléaires de distributions de partons. Dans notre expérience, le détecteur CLAS a été amélioré avec une Chambre à Projection Temporelle Radiale (RTPC pour Radial Time Projection Chamber) pour détecter les noyaux de recul de faible énergie, et un calorimètre intérieur (IC) pour détecter les photons produit à petits angles. Les détails de la structure, de l'étalonnage et du fonctionnement de la RTPC sont présentés. Ensuite, l'analyse des données et la mesure des asymétries faisceau-spin du processus DVCS sont présentés. / The Generalized Parton Distributions (GPDs) are rich structure functions that contain information on quark/anti-quark correlations, and on correlation between longitudinal momentum and the transverse spatial position of partons. These GPDs are accessible via hard exclusive reactions such as Deeply Virtual Compton Scattering (DVCS), i.e. the leptoproduction of a real photon where the photon is emitted by the target hadron. Nuclear DVCS opens a new avenue to explore the nature of medium modifications at the partonic level. In this work, we present the first exclusive measurement of the DVCS process off helium-4 with a longitudinally polarized electron beam of 6 GeV using the CLAS detector in the experimental Hall-B at Jefferson Lab, USA. The helium-4 is of particular interest since the number of GPDs is reduced to one, because of its spin zero. The aim of this study is to understand the nuclear medium modifications of parton distributions. In our experiment, the CLAS detector was upgraded with a Radial Time Projection Chamber (RTPC) to detect the low-energy recoil nuclei, and an Inner Calorimeter (IC) to detect the forward going photons. The details of the structure, calibration and working principle of the RTPC will be presented. Then, the measurement of the beam-spin asymmetries in the DVCS channel will be presented.

Page generated in 0.147 seconds