Seismic Behaviour of Exterior Beam-Column Joints Reinforced with FRP Bars and StirrupsMady, Mohamed Hassan Abdelhamed 25 August 2011 (has links)
Reinforced concrete beam-column joints (BCJs) are commonly used in structures such as parking garages, multi-storey industrial buildings and road overpasses, which might be exposed to extreme weathering conditions and the application of de-icing salts. The use of the non-corrodible fiber-reinforced polymer (FRP) reinforcing bars in such structures is beneficial to overcome the steel-corrosion problems. However, FRP materials exhibit linear-elastic stress-strain characteristics up to failure, which raises concerns on their performance in BCJs where energy dissipation, through plastic behaviour, is required. The objective of this research project is to assess the seismic behaviour of concrete BCJs reinforced with FRP bars and stirrups.
An experimental program was conducted at the University of Manitoba to participate in achieving this objective. Eight full-scale exterior T-shaped BCJs prototypes were constructed and tested under simulated seismic load conditions. The longitudinal and transversal reinforcement types and ratios for the beam and the columns were the main investigated parameters. The experimental results showed that the GFRP reinforced joints can successfully sustain a 4.0% drift ratio without any significant residual deformation. This indicates the feasibility of using GFRP bars and stirrups as reinforcement in the BCJs subjected to seismic-type loading. It was also concluded that, increasing the beam reinforcement ratio, while satisfying the strong column-weak beam concept, can enhance the ability of the joint to dissipate seismic energy.
An analytical investigation was conducted through constructing a finite element model using ANSYS-software. The model was verified against the experimental results in this research. Then, a parametric study was performed on number of different parameters known to affect such joints including column axial load, concrete compressive strength, flexural strength ratio and joint transverse reinforcement. It was concluded that 70% of the column axial load capacity can be recommended as an upper limit to the applied axial loads on the column to avoid damage occurrence within the joint. It was also concluded that a minimum flexural strength ratio of 1.50 is recommended to ensure the strong-column weak-beam mechanism. In addition, a minimum joint transverse reinforcement ratio of 0.60% is recommended to insure that the failure will not occur in the joint zone.
|
2 |
Seismic Behaviour of Exterior Beam-Column Joints Reinforced with FRP Bars and StirrupsMady, Mohamed Hassan Abdelhamed 25 August 2011 (has links)
Reinforced concrete beam-column joints (BCJs) are commonly used in structures such as parking garages, multi-storey industrial buildings and road overpasses, which might be exposed to extreme weathering conditions and the application of de-icing salts. The use of the non-corrodible fiber-reinforced polymer (FRP) reinforcing bars in such structures is beneficial to overcome the steel-corrosion problems. However, FRP materials exhibit linear-elastic stress-strain characteristics up to failure, which raises concerns on their performance in BCJs where energy dissipation, through plastic behaviour, is required. The objective of this research project is to assess the seismic behaviour of concrete BCJs reinforced with FRP bars and stirrups.
An experimental program was conducted at the University of Manitoba to participate in achieving this objective. Eight full-scale exterior T-shaped BCJs prototypes were constructed and tested under simulated seismic load conditions. The longitudinal and transversal reinforcement types and ratios for the beam and the columns were the main investigated parameters. The experimental results showed that the GFRP reinforced joints can successfully sustain a 4.0% drift ratio without any significant residual deformation. This indicates the feasibility of using GFRP bars and stirrups as reinforcement in the BCJs subjected to seismic-type loading. It was also concluded that, increasing the beam reinforcement ratio, while satisfying the strong column-weak beam concept, can enhance the ability of the joint to dissipate seismic energy.
An analytical investigation was conducted through constructing a finite element model using ANSYS-software. The model was verified against the experimental results in this research. Then, a parametric study was performed on number of different parameters known to affect such joints including column axial load, concrete compressive strength, flexural strength ratio and joint transverse reinforcement. It was concluded that 70% of the column axial load capacity can be recommended as an upper limit to the applied axial loads on the column to avoid damage occurrence within the joint. It was also concluded that a minimum flexural strength ratio of 1.50 is recommended to ensure the strong-column weak-beam mechanism. In addition, a minimum joint transverse reinforcement ratio of 0.60% is recommended to insure that the failure will not occur in the joint zone.
|
3 |
Shear behaviour of continuous concrete beams reinforced with GFRP barsMahmoud, Karam Abdou Awad 26 November 2015 (has links)
Continuous beams represent main structural elements in most reinforced concrete (RC) structures such as parking garages and overpass bridges. Deterioration of such structures due to corrosion of steel reinforcement is common in North America. To overcome the corrosion problems, the use of fiber-reinforced polymer (FRP) bars and stirrups becomes a viable alternative to steel reinforcement. However, to date, the shear behaviour of FRP-RC continuous beams has not been explored yet. As such, the objective of this study is to investigate the shear behaviour of such beams.
In this study, twenty four full-scale continuous concrete beams were constructed and tested. The test beams had rectangular cross section with 200-mm width and a height of 300, 550 or 850 mm and were continuous over two equal spans. The main investigated parameters were concrete strength, type and ratio of longitudinal reinforcement, type and ratio of transverse reinforcement and beam effective depth. Moreover, a 3-D nonlinear finite element model (FEM) was constructed to simulate the behaviour of FRP-RC continuous beams. The model was verified against the experimental results and validated against test results from previous studies. Then, the verified/validated model was used to conduct a parametric study to investigate the effect of a wide range of the parameters on the shear behaviour of GFRP-RC beams.
The experimental and FEM results showed that shear-critical GFRP-RC continuous beams exhibited moment redistribution. Also, it was observed that increasing the concrete strength and the longitudinal reinforcement ratio increased the shear strength significantly. Moreover, the presence of GFRP stirrups significantly enhanced the shear strength of the tested beams. Regarding the size effect, test results showed that there was adverse or no size effect on the shear strength of GFRP-RC continuous beams when they failed in the interior shear span while beams failed in the exterior shear span exhibited clear size effect. Furthermore, a comparison between the test results and the provisions of the available models and FRP standards and design guidelines in North America revealed that these design provisions can be safely applied to continuous beams. / February 2016
|
4 |
Behaviour of continuous concrete beams reinforced with FRP barsEl-Mogy, Mostafa 09 December 2011 (has links)
The non-corrodible nature of FRP bars along with their high strength, light weight and ease of installation made it attractive as reinforcement especially for structures exposed to aggressive environment. In addition, the transparency of FRP bars to magnetic and electrical fields makes them an ideal alternative to traditional steel reinforcement in applications sensitive to electromagnetic fields such as magnetic resonance imaging (MRI) units.
Continuous concrete beams are commonly-used elements in structures such as parking garages and overpasses, which might be exposed to extreme weather conditions and the application of de-icing salts. In such structures, using the non-corrodible FRP bars is a viable alternative to avoid steel-corrosion problems. However, the linear-elastic behaviour of FRP materials makes the ability of continuous beams to redistribute loads and moments questionable. The objective of this research project is to investigate the flexural behaviour of continuous concrete beams reinforced with FRP and their capability of moment redistribution. An experimental program was conducted at the University of Manitoba to realize the research objectives. Ten full-scale continuous concrete beams were constructed and tested to failure in the laboratory. The specimens had a rectangular cross-section of 200×300 mm and continuous over two spans of 2,800 mm each. The main investigated parameters were the amount and material of longitudinal reinforcement, the amount and material of transverse reinforcement and the spacing of used stirrups. The experimental results showed that moment redistribution in FRP-reinforced continuous concrete beams is possible if the reinforcement configuration is chosen properly, and is improved by increasing the amount of transverse reinforcement.
A finite element investigation was conducted using ANSYS-software. A 3-D model was created to simulate the behaviour of continuous beams reinforced with FRP. The model was verified against the experimental results obtained from the present study. This verified model was used to investigate the effect of the concrete compressive strength, longitudinal reinforcement ratio, midspan-to-middle support reinforcement ratio and the amount of transverse reinforcement on the behaviour of FRP-reinforced beams. The analytical results of this parametric investigation along with the experimental results were used to propose an allowable limit for moment redistribution in FRP-reinforced continuous concrete beams.
|
5 |
Behaviour of continuous concrete beams reinforced with FRP barsEl-Mogy, Mostafa 09 December 2011 (has links)
The non-corrodible nature of FRP bars along with their high strength, light weight and ease of installation made it attractive as reinforcement especially for structures exposed to aggressive environment. In addition, the transparency of FRP bars to magnetic and electrical fields makes them an ideal alternative to traditional steel reinforcement in applications sensitive to electromagnetic fields such as magnetic resonance imaging (MRI) units.
Continuous concrete beams are commonly-used elements in structures such as parking garages and overpasses, which might be exposed to extreme weather conditions and the application of de-icing salts. In such structures, using the non-corrodible FRP bars is a viable alternative to avoid steel-corrosion problems. However, the linear-elastic behaviour of FRP materials makes the ability of continuous beams to redistribute loads and moments questionable. The objective of this research project is to investigate the flexural behaviour of continuous concrete beams reinforced with FRP and their capability of moment redistribution. An experimental program was conducted at the University of Manitoba to realize the research objectives. Ten full-scale continuous concrete beams were constructed and tested to failure in the laboratory. The specimens had a rectangular cross-section of 200×300 mm and continuous over two spans of 2,800 mm each. The main investigated parameters were the amount and material of longitudinal reinforcement, the amount and material of transverse reinforcement and the spacing of used stirrups. The experimental results showed that moment redistribution in FRP-reinforced continuous concrete beams is possible if the reinforcement configuration is chosen properly, and is improved by increasing the amount of transverse reinforcement.
A finite element investigation was conducted using ANSYS-software. A 3-D model was created to simulate the behaviour of continuous beams reinforced with FRP. The model was verified against the experimental results obtained from the present study. This verified model was used to investigate the effect of the concrete compressive strength, longitudinal reinforcement ratio, midspan-to-middle support reinforcement ratio and the amount of transverse reinforcement on the behaviour of FRP-reinforced beams. The analytical results of this parametric investigation along with the experimental results were used to propose an allowable limit for moment redistribution in FRP-reinforced continuous concrete beams.
|