Protection Mechanisms of Excipients on Lactate Dehydrogenase during Freeze-Thawing and Lyophilization

Mi, Yanli. January 2002 (has links)
Thesis (Ph. D.)--University of Tennessee, Memphis, 2002.
42

Desempenho de eletrocatalisadores PtSnRh suportados em carbono-Sb2O5.SnO2 para a oxidação eletroquímica do etanol, preparados pelo método de redução por álcool / Performance PtSnRh electrocatalysts supported on carbon-Sb2O5.SbO2 for the electro-oxidation of ethanol, prepared by an alcohol-reduction process

CASTRO, JOSE C. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:30Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:48Z (GMT). No. of bitstreams: 0 / Os eletrocatalisadores PtSnRh suportados em carbono-Sb2O5.SnO2, com 20% de massa de metal, foram preparados pelo método de redução por álcool, utilizando H2PtCl6.6H2O (Aldrich), RhCl3.xH2O (Aldrich) e SnCl2.2H2O (Aldrich), como fontes de metais; Sb2O5.SnO2 (ATO) e carbono Vulcan XC72, como suporte; e etileno glicol como agente redutor. Os eletrocatalisadores obtidos foram caracterizados fisicamente por difração de raios-X (DRX) e microscopia eletrônica de transmissão (MET). Por meio dos difratogramas observou-se que os eletrocatalisadores PtSnRh/C-ATO possuem estrutura CFC para a Pt e ligas de Pt, além de vários picos associados ao SnO2 e ATO. Os tamanhos médios dos cristalitos ficaram entre 2 e 4 nm. Por meio das micrografias verificou-se uma boa distribuição das nanopartículas sobre o suporte. Os tamanhos médios das partículas ficaram entre 2 e 3 nm, com boa concordância para os tamanhos médios dos cristalitos. Os desempenhos dos eletrocatalisadores foram analisados por meio de técnicas eletroquímicas e em condições reais de operação utilizando uma célula a combustível unitária alimentada diretamente por etanol. Na cronoamperometria, a temperatura de 50ºC, os eletrocatalisadores com proporção de 85%C+15%ATO para o suporte, apresentaram a melhor atividade, e as proporções atômicas que obtiveram os melhores resultados foram PtSnRh(70:25:05) e (90:05:05). Nos experimentos em célula, o eletrocatalisador PtSnRh(70:25:05)/85C+15ATO apresentou o melhor desempenho. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
43

Estudo experimental comparativo do enxerto homólogo pulmonar tratado pelo processo L-Hydro com o homoenxerto pulmonar a fresco / L-Hydro treated homologous pulmonary graft vs. pulmonary homograft fresco: an experimental, comparative study

Nei Antonio Rey 16 September 2008 (has links)
Os substitutos valvares possuem grande importância pela freqüência da sua utilização e porque de seu bom desempenho depende o sucesso do procedimento cirúrgico realizado. Vários substitutos valvares têm sido empregados, todos com complicações inerentes ao material utilizado, como trombose, calcificação, degeneração, dificuldade de esterilização, custo, complexidade de produção, etc. Buscando disponibilizar homoenxertos preservados de maneira mais simples e econômica, avaliamos uma nova forma de preservação utilizando o polietileno-glicol, método L-Hydro. Este método consiste na extração controlada de substâncias antigênicas e de incorporação de um agente antinflamatório e anti-trombótico. Em dez carneiros jovens substituímos o Tronco Pulmonar, em sete por homoenxertos pulmonares tratados pelo processo L-Hydro e em três por homoenxertos pulmonares a fresco, implantados ortotopicamente e seguidos por 320 dias. Os carneiros foram avaliados por exames laboratoriais e ecocardiográficos. Ao cabo dos 320 dias foram sacrificados, quando se procedeu à avaliação hemodinâmica, radiológica, macroscópica e por microscopia óptica e eletrônica, de varredura e transmissão. Os resultados foram analisados pelo teste t de Student de amostras independentes para os dados contínuos, pela análise de variância para as medidas repetidas e pelo teste exato de Fischer para os dados categóricos. Na evolução clínica e nos exames laboratoriais não conseguimos estabelecer diferenças significativas entre os dois grupos. O ecocardiograma revelou diferença quanto ao gradiente médio pulmonar, significativa aos 10 meses de seguimento, maior no grupo controle do que no grupo L-Hydro. A avaliação radiológica e macroscópica não estabeleceu diferenças. Na avaliação microscópica, óptica e eletrônica, células de revestimento e intersticiais foram encontradas nos dois grupos igualmente. O porcentual de revestimento celular calculado nos dois grupos foi semelhante. Nódulos de celularidade foram observados somente no grupo de homoenxertos a fresco. Em conclusão, estes dados indicam que os dois grupos apresentaram desempenho clínico e hemodinâmico semelhante. Ao ecocardiograma o grupo L-Hydro apresentou melhor desempenho; apresentou também evidências histológicas de repopulação celular intersticial e endotelial. Na análise macro e microscópica, óptica e eletrônica, o grupo L-Hydro apresentou macroscopia, estrutura histológica e ultraestrutural semelhante ao homoenxerto afresco, à exceção de nódulos de maior celularidade intersticial, presentes apenas no homoenxerto a fresco / Valve substitutes are highly important in account of their frequent use and since the success of a surgical procedure depends on their good performance. A variety of valve substitutes have been used, all presenting complications pertaining to their materials, such as thrombosis, calcification, degeneration, sterilization difficulties, cost, production complexity, etc. In an effort to make available homografts preserved in a simpler and less costly way, we evaluated a new preservation form using polyethyleneglycol, the LHydro method. This method consists in the controlled extraction of antigenic substances and the incorporation of an anti-inflammatory and anti-thrombotic agent. We substituted the pulmonary trunk in ten ovines, seven received LHydro treated pulmonary homografts and three received pulmonary homografts fresco, orthotopically implanted and followed-up for 320 days. Ovines where evaluated by means of laboratory tests and echocardiographic exams. At the end of the 320 days, they were euthanized, and hemodynamic, radiology, macroscopic, optic and electronic microscopic, scanning and transmission evaluations were performed. Results were analyzed by Student t test of independent samples for continuous data, by variance analysis of repeated measures, and by Fischer exact test for categorical data. We couldnt establish relevant differences in clinical evolution and laboratory tests between both groups. Echocardiogram revealed a difference in the pulmonary medium gradient, which was significant at the 10 months followup, higher in the control group than in the L-Hydro group. Radiologic and macroscopic evaluations didnt established differences. In the optic and electronic microscopic evaluation, liner and interstitial cells were equally found in both groups. The cell liner percent calculated in both groups was similar. Cellularity nodules were observed only in the homograft fresco group. In conclusion, these data indicate that both groups presented similar clinical and hemodynamic performances. The L-Hydro groups echocardiogram presented a better performance. It also presented histological evidences of interstitial and endothelial cell repopulation. In the macro and optic and electronic microscopic analysis, group L-Hydro presented macroscopy, histological structure and ultra-structural similar to the homograft fresco group, with the exception of nodules with higher interstitial cellularity, present only in the homograft fresco group.
44

Self-diffusivity of a homologous series of ethylene glycols: Experimental measurements, relation with viscosity, correlation and prediction methods

Ascenso, José R., Sequeira, Maria C.M., Avelino, Helena M.N.T., Caetano, Fernando J.P., Faraleira, João M. N. A. 13 July 2022 (has links)
No description available.
45

Estudo da reação de formação de adutos gerados por resina epóxi e polialquileno glicóis. / Study of the reaction of adducts formation generated by epoxy resins and polyalkylene glycols.

Alonso, Thiago Vinícius 21 February 2013 (has links)
A reação entre resinas epóxi e polialquileno glicóis gera um aduto de elevado peso molecular que pode ter aplicações em diferentes segmentos, tais como polímeros usados na composição base de fluidos de têmpera, viscosificantes para lubrificantes e desemulsificantes de petróleo. As condições envolvendo a formação destes adutos possuem referências limitadas na literatura aberta e basicamente envolvem um polialquileno glicol com diferentes funcionalidades, tipicamente duas hidroxilas reagindo com os grupos epóxi presentes na resina epóxi que tipicamente possui funcionalidade igual a dois, a uma temperatura ao redor de 120°C na presença de catalisador de hidróxido de potássio (KOH). O presente trabalho avaliou a formação destes adutos considerando um delineamento experimental de resolução III onde as variáveis de controle foram temperatura, velocidade de agitação do meio reacional, velocidade de adição de resina epóxi, concentração de catalisador e relação molar entre a resina epóxi e o polialquileno glicol. Ao total onze experimentos foram realizados de acordo com o planejamento experimental e incluindo triplicata para avaliação do erro experimental. Diferenças significativas nas características físico químicas dos produtos obtidos tais como viscosidade, teor de epóxi residual e de performance de desemulsificação foram encontradas. Dois produtos apresentaram gelificação. Com um bom nível de confiabilidade estatística pode-se dizer que o peso molecular ponderal médio é influenciado principalmente pelo teor de catalisador seguido da temperatura e proporção molar entre resina epóxi e polialquileno glicol nesta ordem de importância. Com menor nível de significância a conversão é influenciada positivamente com respeito ao incremento do teor de catalisador e da temperatura e pela redução na proporção molar entre resina epóxi e polialquileno glicol. Apesar de terem sido atingidos elevados níveis de conversão de resina epóxi na maioria dos experimentos, pelas analises de GPC foi observado uma grande proporção de polialquileno glicol livre residual nos produtos. Pode-se observar também uma fraca correlação estatística positiva entre a qualidade da separação petróleo-água com respeito à conversão e ao peso molecular numérico médio dos produtos. / The reaction between epoxy resins and polyalkylene glycols generates an adduct of high molecular weight that may have applications in several sectors such as polymers for metal quenchant fluids, demulsifiers and viscosifiers for lubricating oil. The conditions involving the formation of these adducts have limited references in the open literature and basically it involves a polyalkylene glycol having different functionalities, typically two hydroxyl groups reacting with the epoxy groups present in the epoxy resin with typical functionality equal to two at a temperature around 120°C and in the presence of catalyst, potassium hydroxide (KOH). This study evaluated the formation of these adducts considering a resolution III experiment design where the controllable variables were temperature, stirring speed of the reaction medium, rate of addition of epoxy resin, catalyst concentration and molar ratio between the epoxy resin and polyalkylene glycol . In total eleven experiments were carried out according to the experimental design, including three replications at the center point to evaluate the experimental error. Significant differences in chemical and physical characteristics such as viscosity, residual epoxy content and performance of demulsification were found between the synthesized materials. Two products showed gelation. With a good level of statistical reliability it can be considered that the weight average molecular weight is mainly influenced by the amount of catalyst followed by temperature and mole ratio of epoxy resin to polyalkylene glycol in this order of importance. With lower significance level conversion is influenced positively with respect to the increment of the catalyst amount and temperature and by the decrease in molar ratio of epoxy resin and polyalkylene glycol. Despite achieving high levels of conversion of epoxy resin in most of the experiments, by GPC analysis it was observed a large proportion of free residual polyalkylene glycol in the products. It can be observed also a slight positive statistical correlation between the quality of oil-water separation with respect to conversion and number average molecular weight of the products.
46

Mechanisms of the foreign body response to protein and monocyte repellant tetraglyme films /

Mayorga, Luisa E., January 2008 (has links)
Thesis (Ph. D.)--University of Washington, 2008. / Vita. Includes bibliographical references (leaves 298-310).
47

Preparação e caracterização de eletrocatalisadores a base de paládio para oxidação eletroquímica de álcoois em meio alcalino / Preparation and characterization of electrocatalysts based on palladium for electro-oxidation of alcohols in alkaline medium

BRANDALISE, MICHELE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:22Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
48

Estudo da reação de formação de adutos gerados por resina epóxi e polialquileno glicóis. / Study of the reaction of adducts formation generated by epoxy resins and polyalkylene glycols.

Thiago Vinícius Alonso 21 February 2013 (has links)
A reação entre resinas epóxi e polialquileno glicóis gera um aduto de elevado peso molecular que pode ter aplicações em diferentes segmentos, tais como polímeros usados na composição base de fluidos de têmpera, viscosificantes para lubrificantes e desemulsificantes de petróleo. As condições envolvendo a formação destes adutos possuem referências limitadas na literatura aberta e basicamente envolvem um polialquileno glicol com diferentes funcionalidades, tipicamente duas hidroxilas reagindo com os grupos epóxi presentes na resina epóxi que tipicamente possui funcionalidade igual a dois, a uma temperatura ao redor de 120°C na presença de catalisador de hidróxido de potássio (KOH). O presente trabalho avaliou a formação destes adutos considerando um delineamento experimental de resolução III onde as variáveis de controle foram temperatura, velocidade de agitação do meio reacional, velocidade de adição de resina epóxi, concentração de catalisador e relação molar entre a resina epóxi e o polialquileno glicol. Ao total onze experimentos foram realizados de acordo com o planejamento experimental e incluindo triplicata para avaliação do erro experimental. Diferenças significativas nas características físico químicas dos produtos obtidos tais como viscosidade, teor de epóxi residual e de performance de desemulsificação foram encontradas. Dois produtos apresentaram gelificação. Com um bom nível de confiabilidade estatística pode-se dizer que o peso molecular ponderal médio é influenciado principalmente pelo teor de catalisador seguido da temperatura e proporção molar entre resina epóxi e polialquileno glicol nesta ordem de importância. Com menor nível de significância a conversão é influenciada positivamente com respeito ao incremento do teor de catalisador e da temperatura e pela redução na proporção molar entre resina epóxi e polialquileno glicol. Apesar de terem sido atingidos elevados níveis de conversão de resina epóxi na maioria dos experimentos, pelas analises de GPC foi observado uma grande proporção de polialquileno glicol livre residual nos produtos. Pode-se observar também uma fraca correlação estatística positiva entre a qualidade da separação petróleo-água com respeito à conversão e ao peso molecular numérico médio dos produtos. / The reaction between epoxy resins and polyalkylene glycols generates an adduct of high molecular weight that may have applications in several sectors such as polymers for metal quenchant fluids, demulsifiers and viscosifiers for lubricating oil. The conditions involving the formation of these adducts have limited references in the open literature and basically it involves a polyalkylene glycol having different functionalities, typically two hydroxyl groups reacting with the epoxy groups present in the epoxy resin with typical functionality equal to two at a temperature around 120°C and in the presence of catalyst, potassium hydroxide (KOH). This study evaluated the formation of these adducts considering a resolution III experiment design where the controllable variables were temperature, stirring speed of the reaction medium, rate of addition of epoxy resin, catalyst concentration and molar ratio between the epoxy resin and polyalkylene glycol . In total eleven experiments were carried out according to the experimental design, including three replications at the center point to evaluate the experimental error. Significant differences in chemical and physical characteristics such as viscosity, residual epoxy content and performance of demulsification were found between the synthesized materials. Two products showed gelation. With a good level of statistical reliability it can be considered that the weight average molecular weight is mainly influenced by the amount of catalyst followed by temperature and mole ratio of epoxy resin to polyalkylene glycol in this order of importance. With lower significance level conversion is influenced positively with respect to the increment of the catalyst amount and temperature and by the decrease in molar ratio of epoxy resin and polyalkylene glycol. Despite achieving high levels of conversion of epoxy resin in most of the experiments, by GPC analysis it was observed a large proportion of free residual polyalkylene glycol in the products. It can be observed also a slight positive statistical correlation between the quality of oil-water separation with respect to conversion and number average molecular weight of the products.
49

Preparação e caracterização de eletrocatalisadores a base de paládio para oxidação eletroquímica de álcoois em meio alcalino / Preparation and characterization of electrocatalysts based on palladium for electro-oxidation of alcohols in alkaline medium

BRANDALISE, MICHELE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:22Z (GMT). No. of bitstreams: 0 / Neste trabalho foram produzidos eletrocatalisadores Pd/C, Au/C, PdAu/C, PdAuPt/C, PdAuBi/C e PdAuIr/C a partir do método de redução por borohidreto para oxidação eletroquímica de metanol, etanol e etilenoglicol. No método de redução por borohidreto, adiciona-se de uma só vez uma solução alcalina contendo borohidreto de sódio a uma mistura contendo água/2-propanol, precursores metálicos e o suporte de carbono Vulcan XC72. Os eletrocatalisadores obtidos foram caracterizados por espectroscopia de energia dispersiva de raios-X (EDX), difração de raios-X (DRX), microscopia eletrônica de transmissão (MET) e voltametria cíclica. A oxidação eletroquímica do metanol, etanol e etilenoglicol foi estudada por cronoamperometria utilizando a técnica do eletrodo de camada fina porosa. O estudo do mecanismo de oxidação eletroquímica do etanol foi estudado por meio da técnica de espectroscopia no infravermelho com transformada de Fourier (FTIR) in situ. Os melhores eletrocatalisadores foram testados em células alcalinas unitárias alimentadas diretamente por metanol, etanol e etilenoglicol. Estudos preliminares mostraram que a composição atômica adequada para preparar catalisadores ternários é igual a 50:45:05. De acordo com os experimentos eletroquímicos em meio básico, o eletrocatalisador PdAuPt/C (50:45:05) apresentou a maior atividade para oxidação eletroquímica de metanol, enquanto que, nas mesmas condições, o PdAuIr/C foi mais ativo para oxidação do etanol e o PdAuBi/C mais ativo para a oxidação do etilenoglicol. Estes resultados indicam que a adição de ouro na composição dos eletrocatalisadores contribui para uma maior atividade catalítica dos mesmos. Os resultados de FTIR mostraram que o mecanismo da oxidação do etanol se processa de modo indireto, ou seja, a ligação CC não é rompida, formando acetato. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
50

Novel Antimicrobial Topical Gel That Exhibits Inhibitory Effectiveness Toward Common Microbes in Wound Infection

Clark, William Andrew, Ford, Rachel, Vance, Lindsey, Morley, Lexis, Stovall, Thomas, McHale, Leah, Raley, Danny, Fox, Sean 13 June 2019 (has links)
Objectives This research project focused on the inhibitory effectiveness of a novel antimicrobial gel (AMG) towards a panel of common microbes involved in wound infections. Methods A novel antimicrobial topical gel consisting of vitamin E TPGS (tocopherol polyethylene glycol succinate), ascorbyl palmitate, zinc aspartate, lavender oil and deionized distilled water was developed in our laboratory. Various in vitro techniques were used to determine the effectiveness of AMG on prokaryotic and eukaryotic microbes. Results In vitro experiments show that while AMG had varying inhibitory effects on both prokaryotic and eukaryotic microbes, there was a predilection for AMG to inhibit planktonic growth and biofilm formation of Staphylococcus species, most notably Methicillin Resistant Staphylococcus aureus (MRSA). The inhibitory effect of the AMK on planktonic growth was immediate with a four-fold reduction in growth, compared to controls, within 4 to 6 hrs of induction. Within 24 hrs S. aureus growth was minimal and complete inhibition of growth was achieved within 48 hrs. In an in vitro biofilm model, the AMG inhibited Staphylococcus biofilm attachment by 67% (density), 82% (mass) and 95% (viability). On pre-formed established biofilms, the AMG was able to inhibit 47% (density), 47% (mass) and 44% (viability) Staphylococcus biofilms. Antibiotic comparison experiments demonstrated that the MIC (minimum inhibitory concentration) of Mupirocin was Conclusions AMG is nontoxic to humans and canines and demonstrates potential for use in wound infections as an alternative to commonly prescribed antibiotics without the unintended drug resistance seen with antibiotics. AMG is an effective treatment option, this far in vitro, for Staphylococcus infections that are particularly prone to biofilm growth.