• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 171
  • 41
  • 9
  • 6
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 350
  • 350
  • 75
  • 68
  • 65
  • 40
  • 40
  • 39
  • 37
  • 34
  • 28
  • 27
  • 25
  • 25
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Fan-Shaped Hole Film Cooling on Turbine Blade and Vane in a Transonic Cascade with High Freestream Turbulence: Experimental and CFD Studies

Xue, Song 23 August 2012 (has links)
The contribution of present research work is to experimentally investigate the effects of blowing ratio and mainstream Mach number/Reynolds number (from 0.6/8.5X10⁵ to 1.0/1.4X10⁶) on the performance of the fan-shaped hole injected turbine blade and vane. The study was operated with high freestream turbulence intensity (12% at the inlet) and large turbulence length scales (0.26 for blade, 0.28 for vane, normalized by the cascade pitch of 58.4mm and 83.3mm respectively). Both convective heat transfer coefficient, in terms of Nusselt number, and adiabatic effectiveness are provided in the results. Present research work also numerically investigates the shock/film cooling interaction. A detailed analysis on the physics of the shock/film cooling interaction in the blade cascade is provided. The results of present research suggests the following major conclusions. Compared to the showerhead only vane, the addition of fan-shaped hole injection on the turbine Nozzle Guide Vane (NGV) increases the Net Heat Flux Reduction (NHFR) 2.6 times while consuming 1.6 times more coolant. For the blade, combined with the surface curvature effect, the increase of Mach number/Reynolds number results in an improved film cooling effectiveness on the blade suction side, but a compromised cooling performance on the blade pressure side. A quick drop of cooling effectiveness occurs at the shock impingement on the blade suction side near the trailing edge. The CFD results indicate that this adiabatic effectiveness drop was caused by the strong secondary flow after shock impingement, which lifts coolant away from the SS surface, and increases the mixing. This secondary flow is related to the spanwise non-uniform of the shock impingement. / Ph. D.
272

Heat Transfer Performance Improvement Technologies for Hot Gas Path Components in Gas Turbines

Ravi, Bharath Viswanath 14 June 2016 (has links)
In the past few decades, the operating temperatures of gas turbine engines have increased significantly with a view towards increasing the overall thermal efficiency and specific power output. As a result of increased turbine inlet temperatures, the hot gas path components downstream of the combustor section are subjected to high heat loads. Though materials with improved temperature capabilities are used in the construction of the hot gas path components, in order to ensure safe and durable operation, the hot gas path components are additionally supplemented with thermal barrier coatings (TBCs) and sophisticated cooling techniques. The present study focusses on two aspects of gas turbine cooling, namely augmented internal cooling and external film cooling. One of the commonly used methods for cooling the vanes involves passing coolant air bled from the compressor through serpentine passages inside the airfoils. The walls of the internal cooling passages are usually roughened with turbulence promoters like ribs to enhance heat transfer. Though the ribs help in augmenting the heat transfer, they have an associated pressure penalty as well. Therefore, it is important to study the thermal-hydraulic performance of ribbed internal cooling passages. The first section of the thesis deals with the numerical investigation of flow and heat transfer characteristics in a ribbed two-pass channel. Four different rib shapes- 45° angled, V-shaped, W-shaped and M-shaped, were studied. This study further aims at exploring the performance of different rib-shapes at a large rib pitch-to-height ratio (p/e=16) which has potential applications in land-based gas turbines operating at high Reynolds numbers. Detailed flow and heat transfer analysis have been presented to illustrate how the innate flow physics associated with the bend region and the different rib shapes contribute to heat transfer enhancement in the two-pass channel. The bend-induced secondary flows were observed to significantly affect the flow and heat transfer distribution in the 2nd pass. The thermal-hydraulic performance of V-shaped and 45° angled ribs were better than W-shaped and M-shaped ribs. The second section of the study deals with the analysis of film cooling performance of different hole configurations on the endwall upstream of a first stage nozzle guide vane. The flow along the endwall of the airfoils is highly complex, dominated by 3-dimensional secondary flows. The presence of complex secondary flows makes the cooling of the airfoil endwalls challenging. These secondary flows strongly influence endwall film cooling and the associated heat transfer. In this study, three different cooling configurations- slot, cylindrical holes and tripod holes were studied. Steady-state experiments were conducted in a low speed, linear cascade wind tunnel. The adiabatic film cooling effectiveness on the endwall was computed based on the spatially resolved temperature data obtained from the infrared camera. The effect of mass flow ratio on the film cooling performance of the different configurations was also explored. For all the configurations, the coolant jets were unable to overcome the strong secondary flows inside the passage at low mass flow ratios. However, the coolant jets were observed to provide much better film coverage at higher mass flow ratios. In case of cylindrical ejection, the effectiveness values were observed to be very low which could be because of jet lift-off. The effectiveness of tripod ejection was comparable to slot ejection at mass flow ratios between 0.5-1.5, while at higher mass flow ratios, slot ejection was observed to outperform tripod ejection. / Master of Science
273

Heat Transfer Coefficient and Adiabatic Effectiveness Measurements for an Internal Turbine Vane Cooling Feature

Prausa, Jeffrey Nathaniel 10 June 2004 (has links)
Aircraft engine manufacturers strive for greater performance and efficiency by continually increasing the turbine inlet temperature. High turbine inlet temperatures significantly degrade the lifetime of components in the turbine. Modern gas turbines operate with turbine inlet temperatures well above the melting temperature of key turbine components. Without active cooling schemes, modern turbines would fail catastrophically. This study will evaluate a novel cooling scheme for turbine airfoils, called microcircuit cooling, in which small cooling channels are located extremely close to the surface of a turbine airfoil. Coolant bled from the compressor passes through the microcircuits and exits through film cooling slots. On further cooling benefit is that the microcircuit passages are filled with irregular pin fin features that serve to increase convective cooling through the channels. Results from this study indicate a strong interaction between the internal microcircuit features and the external film-cooling from the slot exit. Asymmetric cooling patterns downstream of the slot resulted from the asymmetric pin fin design within the microcircuit. Adiabatic effectiveness levels were found to be optimum for the slot design at a blowing ratio of 0.37. The pin fin arrangement along with the impingement cooling at the microcircuit entrance increased the area-averaged heat transfer by a factor of three, relative to an obstructed channel, over a Reynolds range of 5,000 to 15,000. / Master of Science
274

Performance of a Showerhead and Shaped Hole Film Cooled Vane at High Freestream Turbulence and Transonic Conditions

Newman, Andrew Samuel 04 June 2010 (has links)
An experimental study was performed to measure surface Nusselt number and film cooling effectiveness on a film cooled first stage nozzle guide vane using a transient thin film gauge (TFG) technique. The information presented attempts to further characterize the performance of shaped hole film cooling by taking measurements on a row of shaped holes downstream of leading edge showerhead injection on both the pressure and suction surfaces (hereafter PS and SS) of a 1st stage NGV. Tests were performed at engine representative Mach and Reynolds numbers and high inlet turbulence intensity and large length scale at the Virginia Tech Transonic Cascade facility. Three exit Mach/Reynolds number conditions were tested: 1.0/1,400,000; 0.85/1,150,000; and 0.60/850,000 where Reynolds number is based on exit conditions and vane chord. At Mach/Reynolds numbers of 1.0/1,450,000 and 0.85/1,150,000 three blowing ratio conditions were tested: BR = 1.0, 1.5, and 2.0. At a Mach/Reynolds number of 0.60/850,000, two blowing ratio conditions were tested: BR = 1.5 and 2.0. All tests were performed at inlet turbulence intensity of 12% and length scale normalized by leading edge diameter of 0.28. Film cooling effectiveness and heat transfer results compared well with previously published data, showing a marked effectiveness improvement (up to 2.5x) over the showerhead only NGV and agreement with published showerhead-shaped hole data. NHFR was shown to increase substantially (average 2.6x increase) with the addition of shaped holes, with only a small increase (average 1.6x increase) in required coolant mass flow. Heat transfer and effectiveness augmentation with increasing blowing ratio was shown on the pressure side, however the suction side was shown to be less sensitive to changing blowing ratio. Boundary layer transition location was shown to be within a consistent region on the suction side regardless of blowing ratio and exit Mach number. / Master of Science
275

An experimental investigation of the conversion of NO to NO2 in a simulated gas turbine environment

Hunderup, James W. 16 June 2009 (has links)
Unexpectedly high concentrations of NO₂ have been noted in stack emissions from industrial gas turbines. NO₂ formation appears to occur through the so called "HO₂ mechanism II in which NO combines with HO₂ to produce NO₂ and OH. In this study, the formation of NO₂ was investigated through computer modeling and experimental testing. Computer modeling utilized the CHEMKIN chemical kinetics program and a subset of a previously published C-H-O-N system mechanism. Experimental work was conducted using a high pressure flow reactor designed and built in the course of the study. The effects of pressure, temperature, and the presence of a NO₂ promoting hydrocarbon, methane, were investigated. It was discovered that as pressure increased from 1 atm. to 8.5 atm., the rate and amount of NO converted to NO₂ also increased. There also appeared to be a temperature "window" between approximately 800 and 1000 K in which NO to NO₂ conversion readily occurred. The presence of methane was seen to enhance NO conversion to NO₂, and a ratio of [CH₄]/[NO] was found to be a useful parameter in predicting NO₂ formation. Significant NO conversion to NO₂ was noted for [CH₄]/[NO] > 1 at the hydrocarbon injection point. Experimental results validated those trends obtained from modeling with a modified C-H-O-N mechanism. / Master of Science
276

Application of a modified k-[epsilon] turbulence model to gas turbine combustor geometries

Relation, Heather L. 31 October 2009 (has links)
The k-epsilon turbulence model yields inconsistent and diffusive results for swirling and recirculating flows, which are characteristic of combustor geometries. Y. S. Chen and S. W. Kim propose a modification to the k-epsilon turbulence model which has shown improved predictions for several complex flows. This study evaluates the application of the Chen modification of the k-epsilon turbulence model to combustor geometries by applying the modification to two burner test cases which contain the elemental flow characteristics of an industrial gas turbine combustor. The modification is implemented into a commercial computational fluid dynamics (CFD) code. The results show an improved prediction of the location, shape and size of the primary centerline recirculation zone for both cases. The large swirl and axial velocity gradients, which are diffused by the standard k-epsilon model, are preserved by the Chen model. The overprediction of turbulent eddy viscosity in regions of high shear, which is characteristic of k-epsilon, is controlled by the Chen modification. In industrial combustor design, the prediction of the location, size and shape of primary flow features is of paramount importance. The Chen modification can, therefore, be considered a successful improvement to the k-epsilon model and can be considered applicable to combustor geometries. / Master of Science
277

An experimental investigation of turbine blade tip heat transfer and tip gap flows in the supersonic regime

Yang, Timothy T. 11 July 2009 (has links)
Gas turbine blade tip heat transfer and tip gap flow phenomena has been explored experimentally in a stationary cascade for blade exit Mach numbers = 1.2 to 1.4. Experimental results were found to agree well with qualitative predictions performed at GE Aircraft Engines. The pressure distribution in the blade tip cavity of a grooved tip blade was found to vary little with either Mach number or tip gap height. The tip cavity pressure was, however, a strong function of location. The tip cavity pressure distribution coupled with the pressure side distribution near the tip was speculated to drive the leakage flow across the blade tip from mid-chord aft based on surface flow visualization studies using an oil/dye mixture. Heat flux on the tip cavity floor was successfully measured using a thin-film Heat Flux Microsensor. Results of these measurements are consistent with previous studies in the subsonic regime. The convection coefficients on the tip cavity floor were found to be three times those found on the suction side airfoil surface near the trailing edge. Convection coefficients were found not to vary with either tip gap height or Mach number. The fluctuating component of heat flux was found to be at least 25% of the total heat flux. / Master of Science
278

Mechanical behavior and damage mechanisms of woven graphite-polyimide composite materials

Wagnecz, Linda 21 July 2010 (has links)
The behavior of 8-harness satin woven Celion 3000/PMR-15 graphite-polyimide was experimentally investigated. Unnotched and center-notched specimens from (0)₁₅, (0)₂₂, and (0,45,0, - 45,0,0, - 45,0,45,0)₂ laminates were tested. Material properties were measured and damage development documented under monotonic tension, sustained incremental tension, and tension-tension fatigue loading. Damage evaluation techniques included stiffness monitoring, penetrant-enhanced X-ray radiography, laminate deply, and residual strength measurement. Material properties of the woven graphite-polyimide were comparable to those of woven graphite-epoxy. Damage development in woven graphite-polyimide was quite different than in non-woven graphite-epoxy. Matrix cracking was denser and delamination less extensive in the graphite-polyimide material system, and as a result, increases in notched residual tensile strength were much lower. A ply level failure theory was used to successfully predict the notched tensile strength of the (0,45,0, - 45,0,0, - 45,0,45,0)₂ laminate based on experimental data from the (0)₂₂ laminate. A simple method was used to simulate fatigue damage in a (0)₂₂ notched specimen to predict residual strength as a function of fatigue life. The advantages and disadvantages of the ply level failure theory used in this study are discussed. / Master of Science
279

Film Cooling Predictions Along the Tip and Platform of a Turbine Blade

Hohlfeld, Erik Max 11 June 2003 (has links)
Turbine airfoils are exposed to the hottest temperatures in the gas turbine with temperatures typically exceeding the melting point of the blade material. Cooling methods investigated in this computational study included parasitic cooling flow losses, which are inherent to engines, and microcircuit channels. Parasitic losses included dirt purge holes, located along the blade tip, and platform leakage flow, which result from gaps between various turbine components. Microcircuits are a novel cooling technique involving small air passages placed near the airfoil surface to enhance internal cooling. This study evaluated the benefit of external film-cooling flow exhausted from strategically placed microcircuits. Along the blade tip, predictions showed mid-chord cooling was independent of the blowing from microcircuit exits. The formation of a pressure side vortex was found to develop for most microcircuit film-cooling cases. Significant leading edge cooling was obtained from coolant exiting from dirt purge holes with a small tip gap while little cooling was seen with a large tip gap. Along the blade platform, the migration of coolant from the front leakage was shown to cool a considerable part of the platform. Several hot spots were predicted along the platform, which were circumvented through the placement of microcircuit channels. Ingestion of hot mainstream gas was predicted along the aft portion of the gutter and agreed with distress exhibited by actual gas turbine engines. / Master of Science
280

The Effect of Combustor Exit to Nozzle Guide Vane Platform Misalignment on Heat Transfer over an Axisymmetric Endwall at Transonic Conditions

Mayo, David Earl Jr. 01 July 2016 (has links)
This paper presents details of an experimental and computational investigation on the effect of misalignment between the combustor exit and nozzle guide vane endwall on the heat transfer distribution across an axisymmetric converging endwall. The axisymmetric converging endwall investigated was representative of that found on the shroud side of a first stage turbine nozzle section. The experiment was conducted at a nominal exit M of 0.85 and exit Re 1.5 x 10⁶ with an inlet turbulence intensity of 16%. The experiment was conducted in a blowdown transonic linear cascade wind tunnel. Two different inlet configurations were investigated. The first configuration, Case I, was representative of a combustor exit aligned to the nozzle platform, with a gap located at the interface of the tow components. The second configuration, Case II, the endwall platform was offset in the span-wise direction to create a backward facing step at the inlet. This step is representative of a misalignment between the combustor exit and the NGV platform. An infrared camera was used to capture the temperature history on the endwall, from which the endwall heat transfer distribution was determined. A numerical study was also conducted by solving RANS equations using ANSYS Fluent v.15. The numerical results provided insight into the passage flow field which explained the observed heat transfer characteristics. Case I showed the typical characteristics of transonic vane cascade flow, such as the separation line, saddle point, and horseshoe vortices. The presence of a gap at the combustor-nozzle interface facilitated the formation of a separated flow which propagated through the passage. This flow feature caused the passage vortex reattach to the SS vane at 0.44 x/C. The addition of the platform misalignment in Case II caused the flow reattachment region to occur near the vane LE plane. The separated flow which formed at the inlet step, merged with the recirculation region on the endwall platform, forming two counter-rotating auxiliary vortices. These vortices significantly delayed migration of the passage vortex, causing it to reattach on the SS vane at 0.85 x/C. These two flow features also had a significant effect on the endwall heat transfer characteristics. The heat transfer levels on the endwall platform, from -0.50 to +0.50 Cx relative to the vane LE, had an average increase of ~40%. However, downstream of the vane mid-passage, the heat transfer levels showed no appreciable heat transfer augmentation due to flow acceleration through the passage throat. / Master of Science

Page generated in 0.0629 seconds