• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Validação do teste de atividade de vida diária-glittre em indivíduos com a doença de Parkinson / Validation of the glittre daily life activity test in individuals with Parkinson's disease

Silva, Dayse Danielle de Oliveira 07 March 2018 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-20T19:56:10Z No. of bitstreams: 1 Dayse Danielle de Oliveira Silva.pdf: 1056626 bytes, checksum: 3d7b90a2e792675f504f13d5b0cfc13c (MD5) / Made available in DSpace on 2018-07-20T19:56:10Z (GMT). No. of bitstreams: 1 Dayse Danielle de Oliveira Silva.pdf: 1056626 bytes, checksum: 3d7b90a2e792675f504f13d5b0cfc13c (MD5) Previous issue date: 2018-03-07 / Objectives: Study I - To analyze the psychometric properties of the Unified Parkinson's Disease Rating Scale (UPDRS). Study II - Analyze the construct validity and the discriminatory power and verify if the Daily Life Activity-Glittre test (AVD-Glittre) is able to differentiate the stages of Parkinson's Disease (PD). Methods: Study I - systematic review based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyzes (PRISMA). The searches in PubMed, SciELO, PsycINFO, LILACS, PEDro and Cochrane Central Register of Controlled Trials databases occurred between March 1 and May 31, 2017, using the terms "Parkinson's Disease", "Unified Parkinson's Disease Rating Scale "" UPDRS "," outcome assessment "," psychometrics "," reliability "and" reproducibility ", including suggested synonyms, without language restrictions. Study II - cross-sectional, observational study performed at the Respiratory Exercise and Health Laboratory (LERES) at the University of Pará-UEPA from May 2016 to August 2016. Thirty individuals with PD (GP), and 19 healthy individuals in the control group (CG) were submitted to the study. Age from 50 to 80 years, without sex restrictions, hemodynamically stable (BP <140mmHg x 90mmHg), cognitively preserved. All participants had the following parameters before, during and after the tests: Blood Pressure (BP), Heart Rate (HR), Peripheral Oxygen Saturation (SpO2) and effort perception, as well as the perception of fatigue of lower members, by the Modified Borg Scale. Participants of the GP, after the application of the AVD-Glittre test, also underwent UPDRS, the 6-minute Walk Test (6MWT) and the 10-meter Walk Test (TC10m). Results: Study I - 19 studies were analyzed. The internal consistency for sections I to IV presented strong positive evidence. The reproducibility of section IV presented strong negative evidence. All sections presented strong negative evidence for content validity; in the hypothesis test of sections II and III, strong positive evidence was observed. The AVD-Glittre test presented a moderate positive correlation with section II (rho = 0.371, p = 0.043), a moderate to strong positive correlation with section III (rho = 0.658, p = 0.000) and a moderate correlation with the total UPDRS score (rho = 0.552; p = 0.002). There was a negative correlation between the AVD-Glittre test and the 6MWT (rho - 0.772, p <0.001), and a positive correlation, with a strong magnitude with the TC10m (rho = 0.854, p <0.001). The area under the ROC curve (AUC) obtained was 0.855 (confidence interval: 0.753 to 0.957, p = 0.000), characterizing the test as a good discriminatory instrument to differentiate individuals with PD from healthy subjects. Conclusions: Sections II and III presented reliability evidence to assess ADLs and motor performance of individuals with PD, respectively, however the correlation with the AVD-Glittre test was of moderate magnitude. The AVD-Glittre test proved to be valid to assess functional capacity, with discriminatory power to differentiate patients from healthy, but was not able to differentiate the various stages of PD. / Objetivos: Estudo I - Analisar as propriedades psicométricas da Unified Parkinson's Disease Rating Scale (UPDRS). Estudo II - Analisar a validade do construto e o poder discriminatório e verificar se o teste de Atividade de Vida Diária-Glittre (AVD-Glittre) é capaz de diferenciar os diversos estágios da Doença de Parkinson (DP). Métodos: Estudo I – revisão sistemática baseada no Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). As buscas nas bases PubMed, SciELO, PsycINFO, LILACS, PEDro e Cochrane Central Register of Controlled Trials, ocorreram entre 01 de março e 31 de maio de 2017, utilizando-se os termos: “Parkinson’s Disease”, “Unified Parkinson's Disease Rating Scale”, “UPDRS”, “outcome assessment”, “psychometrics”, “reliability” e “reproducibility”, incluindo sinônimos sugeridos, sem restrições de idiomas. Estudo II - estudo observacional, de corte transversal, realizado no Laboratório de Exercício Resistido e Saúde (LERES) da Universidade do Estado do Pará- UEPA, no período de maio a agosto de 2016. Participaram 30 indivíduos com DP, alocados no grupo Parkinson (GP) e 19 indivíduos sadios no grupo controle (GC). Idade entre 50 e 80 anos (GP=62,10 +8,62 e GC= 63,84+8,18), ambos os gêneros, hemodinamicamente estáveis (PA < 140mmHg x 90mmHg), cognitivamente preservados. Foram coletadas a Pressão Arterial (PA), Frequência Cardíaca (FC), Saturação Periférica de Oxigênio (SpO2) e percepção do esforço, assim como a percepção da fadiga de MMII, pela escala de Borg Modificada antes, durante e após os testes. Os participantes do GP também foram submetidos à avaliação pela UPDRS, Teste de Caminhada de 6 minutos (TC6’) e Teste de Caminhada de 10 metros (TC10m). Resultados: Estudo I – 19 estudos foram analisados. A consistência interna para as seções I a IV apresentou forte evidência positiva. A reprodutibilidade da seção IV apresentou uma forte evidência negativa. Todas as seções apresentaram uma forte evidência negativa para validade de conteúdo; no teste de hipóteses das seções II e III foi observada uma forte evidência positiva. Estudo II – O teste AVD-Glittre apresentou correlação positiva, de moderada magnitude com a seção II (rho=0,371; p=0,043), correlação positiva de moderada a forte com a seção III (rho=0,658; p=0,000) e uma correlação moderada com a pontuação total da UPDRS (rho=0,552; p=0,002). Observou-se correlação negativa, de forte magnitude entre o teste AVD-Glittre e o TC6’ (rho - 0,772, p<0,001), e uma correlação positiva, de forte magnitude com o TC10m (rho=0,854, p <0,001). A área sob a curva ROC (AUC) obtida foi de 0,855 (intervalo de confiança: 0,753 a 0,957; p=0,000), caracterizando o teste como um bom instrumento discriminatório para diferenciar indivíduos com DP dos saudáveis. Conclusão: As seções II e III, apresentaram evidências de confiabilidade para avaliar as AVDs e o desempenho motor de indivíduos com DP respectivamente, no entanto a correlação com o teste AVD-Glittre foi de moderada magnitude. O teste AVD-Glittre mostrou-se válido para avaliar a capacidade funcional, com poder discriminatório para diferenciar os doentes dos saudáveis, no entanto não foi capaz de diferenciar os diversos estágios da DP.
2

Reprodutibilidade do teste de Atividade de Vida Diária (AVD) - Glittre em indivíduos com doença de Parkinson / Reproducibility of the Glittre Daily Life activity test in individuals with Parkinson's disease

Sá, Mariana dos Anjos Furtado de 07 March 2018 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-20T20:38:01Z No. of bitstreams: 1 Mariana dos Anjos Furtado de Sá.pdf: 757823 bytes, checksum: c621e732da266331642bb34898bd1ee0 (MD5) / Made available in DSpace on 2018-07-20T20:38:01Z (GMT). No. of bitstreams: 1 Mariana dos Anjos Furtado de Sá.pdf: 757823 bytes, checksum: c621e732da266331642bb34898bd1ee0 (MD5) Previous issue date: 2018-03-07 / Objective: Study I: Identify the evaluation instruments utilized to measure the Functional Capability (FC) and the performance in the activities of daily living (ADL) of people with Parkinson’s disease (PD) in clinical trials in the field of physiotherapy. Study II: Analyze the reproducibility of the ADL test – Glittre in individuals with Parkinson’s disease (PD) and analyze the minimum detectable change in this test results in subjects with PD. Methods and Materials: Study I: A systematic review was carried out with a search in four databases. Extracted terms from Descritores em Ciências da Saúde (DeCS) and Medical Subject Headings (MeSH) were utilized. The terms were Parkinson’s disease, Physiotherapy, Daily Activities, Functional Capability and randomized clinical trials, including the suggested synonyms, in the Portuguese, English and Spanish language. Clinical trials were included in which the outcome were Functional Capability (FC) and/or the Physical Activities of Daily Living (ADL) from subjects with PD submitted to Physical Therapy. Two independent evaluators selected studies based on the eligibility criteria of the PEDro scale. A third evaluator analyzed the differences between the evaluators that selected the studies. Study II: Population sample composed of 30 subjects with PD, mean age 62±9 years old, both sexes (17 men), 8 (26,6%) at the Stage 1 of the Hoehn and Yahr classification, 11 (36,7%) at Stage 2 and 11 (36,7%) at Stage 3. The Glittre test (GT), was made in the intra-rater analysis twice, by the same rater, with a 30-minute interval, and in the inter-rater analysis both tests were made, by two distinct raters, with an interval of 1 to 7 days. The Intraclass correlation coefficient (ICC) was used to the reproducibility analysis and the proposed test by Bland and Altman to agreement analysis. Results: Study I: 10 studies were found, all using the total UPDRS or their II and III domains to evaluate, respectively, the performance of physical activities of daily living and the motor performance. The Timed Up and Go (TUG), was utilized in two out of the ten selected studies, was the only utilized instrument to evaluate the proposed outcomes, already validated to PD, in addition to UPDRS. Several other general measures, such as the 6-minute walk Test (6WT) and the Activity Card Sort (ACS) were cited as tools developed to other clinical populations, with the objective of evaluate the FC and/or ADL. Study II: The results demonstrated that the Glittre test execution time was significantly shorter in the retest (Intra-rater) with ICC= 0,92 (95%, CI= 0,83-0,96; P<0,0001). The results of the second evaluator were significantly shorter ICC= 0,86 (95%, CI = 0,71-0,93; P<0,0001). The MDC was 0,24 minutes (Intra-raters) and 0,62 minutes (Inter-raters). Conclusion: The study I results suggest that validation studies of other instruments are necessary to be utilized, as alternatives, to the evaluation of these outcomes. In the study II, the presented differences among the evaluators demonstrate the best results at the second test, pointing that at least two repetitions are necessary to obtain reliable evaluations. / Objetivo: Estudo I: Identificar os instrumentos de avaliação utilizados para mensurar a capacidade funcional (CF) e o desempenho nas atividades de vida diária (AVD´s) de pessoas com doença de Parkinson (DP) em ensaios clínicos na área da fisioterapia. Estudo II: Analisar a reprodutibilidade do teste de AVD - Glittre em indivíduos com a doença de Parkinson (DP) e analisar a mínima mudança detectável nos resultados deste teste em indivíduos com DP. Materiais e métodos: Estudo I: Foi realizada uma revisão sistemática com uma busca em quatro bases de dados. Foram utilizados termos extraídos dos Descritores em Ciências da Saúde (DeCS) e Medical Subject Headings (MeSH). Os termos foram Doença de Parkinson, fisioterapia, Atividades Diárias, Capacidade Funcional e ensaios clínicos randomizados, incluindo os sinônimos sugeridos, nos idiomas português, inglês e espanhol. Foram incluídos ensaios clínicos em que os desfechos eram a Capacidade Funcional (CF) e/ou as Atividades de Vida Diária (AVD´s) de pessoas com DP submetidas à Fisioterapia. Dois revisores independentes selecionaram os estudos baseados nos critérios de elegibilidade da escala PEDro. Um terceiro revisor avaliou as diferenças entre os revisores que selecionaram os estudos. Estudo II: Amostra populacional composta por 30 indivíduos com DP, idade média 62±9 anos, ambos os sexos (17 homens), 8 (26,6%) no estágio 1 da classificação de Hoehn e Yahr, 11 (36,7%) no estágio 2 e 11 (36,7%) no estágio 3. O teste Glittre (TG) foi realizado duas vezes, pelo mesmo avaliador, com intervalo de 30 minutos, para análise intra-avaliador e na análise interavaliadores os dois testes foram realizados por dois avaliadores distintos, com intervalo de 1 a 7 dias. Utilizou-se o coeficiente de correlação intraclasse (CCI) para análise da reprodutibilidade e o teste proposto por Bland e Altman para análise de concordância. Resultados: Estudo I: 10 estudos foram encontrados, todos utilizaram a UPDRS total ou os seus domínios II e III para avaliar, respectivamente, o desempenho nas atividades de vida diária e o desempenho motor. O Timed Up and Go (TUG) foi utilizado em dois dos dez estudos selecionados, foi o único instrumento utilizado para avaliar os desfechos propostos, já validado para DP, além da UPDRS. Diversas outras medidas genéricas, como o Teste de caminhada de 6 minutos (TC6) e o Activity Card Sort (ACS) foram citadas como ferramentas desenvolvidas para outras populações clínicas, com o objetivo de avaliar a CF e/ou AVD. Estudo II: Os resultados demonstraram que o tempo de execução do teste Glittre era significativamente menor no reteste (intra-avaliador) com CCI= 0,92 (95%, IC= 0,83-0,96; P<0,0001). Resultados do segundo examinador foram significativamente mais baixos CCI=0,86 (95%, IC = 0,71-0,93; P<0,0001). A MMD foi de 0,24 minutos (intra-avaliadores) e de 0,62 minutos (interavaliadores). Conclusão: Os resultados do estudo I sugerem que estudos de validação de outros instrumentos são necessários para serem utilizados, como alternativas, para a avaliação destes desfechos. No estudo II, as diferenças apresentadas entre os avaliadores mostram os melhores resultados no segundo teste, apontando que pelo menos duas repetições são necessárias para obter avaliações confiáveis.
3

Reprodutibilidade do teste de Atividade de Vida Diária AVD-Glittre em indivíduos hemiparéticos decorrente de Acidente Vascular Encefálico (AVE) / Reproducibility of the AVD-Glittre in hemiparetic individuals due to stroke

Teodósio, Amanda da Conceição 13 December 2016 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-23T18:13:52Z No. of bitstreams: 1 Amanda da Conceição Teodósio.pdf: 1530942 bytes, checksum: 16e553986846bcca3d0c579167b8f9bc (MD5) / Made available in DSpace on 2018-07-23T18:13:53Z (GMT). No. of bitstreams: 1 Amanda da Conceição Teodósio.pdf: 1530942 bytes, checksum: 16e553986846bcca3d0c579167b8f9bc (MD5) Previous issue date: 2016-12-13 / The stroke can cause several sequels compromising the neuromuscular, cardiorespiratory system and consequently the performance of the functional activities. For this, an evaluation tool is needed that incorporates the capacity and the functional performance of these individuals. The ADL Glittre test proposes this objective, being already validated in individuals with COPD, but not yet applied in the population with neurological alterations. Objective: To analyze the reproducibility of the ADL Glittre test in hemiparetic individuals due to stroke. METHODS: Patient profiles were plotted for gender, age, anthropometric data, side and site of injury, motor impairment (Fugl Meyer), Mental State (Mini Mental) and Functional Mobility Scale (FMS). The ADL Glittre test was performed with the upper limb not affected, its main outcome being the completion time. For reproducibility, the subject was submitted to four evaluative moments, two intra-rater evaluations and two inter-rater evaluations, adopted randomly. Variables were normalized by the Shapiro-Wilk test, reliability by means of the Intra-Class Correlation Coefficient (ICC), the Intra and Interim Concordance by means of Standard Error of Measure (EPM) and Minimum Changeable Detection (MMD). Results: There was a significant difference in the intra-rater evaluations (1 and 2), but the differences were smaller than the MMD (1.27 and 1.14 seconds). There was no significance in the outcome of the test in the inter-rater evaluations (p = 0.20). Conclusion: The Glittre AVD is reproducible for the hemiparetic population, which I completed in approximately five minutes. Due to the learning effect it is necessary to apply the test and retest. / O AVE pode ocasionar diversas sequelas comprometendo o sistema neuromuscular, cardiorrespiratório e consequentemente o desempenho das atividades funcionais. Para isso, faz-se necessária uma ferramenta de avaliação que incorpore a capacidade e o desempenho funcional desses indivíduos. O teste AVD Glittre propõe esse objetivo, sendo já validado em indivíduos com DPOC, porém ainda não aplicado na população com alterações neurológicas. Objetivo: Analisar a reprodutibilidade do teste de AVD Glittre em indivíduos hemiparéticos decorrente de AVE. Métodos: Os perfis dos pacientes foram traçados avaliando-se sexo, idade, dados antropométricos, lado e local da lesão, comprometimento motor (Fugl Meyer), Estado Mental (Mini mental) e Escala de Mobilidade Funcional (FMS). O teste AVD Glittre foi realizado com o membro superior não acometido, sendo seu desfecho principal o tempo de conclusão. Para a reprodutibilidade o indivíduo foi submetido a quatro momentos avaliativos, duas avaliações intra-avaliadores e duas avaliações inter avaliadores, adotadas de forma aleatorizada. A variáveis foram normalizadas pelo teste Shapiro- Wilk, a confiabilidade por meio do Coeficiente de Correlação Intra classe (CCI), a Concordância Intra e Inter avaliadores por meio do Erro Padrão de Medida (EPM) e pela Mínima Mudança Detectável (MMD). Resultados: Houve diferença significante nas avaliações intra-avaliadores (1 e 2) porém, as diferença foram menores que a MMD (1,27 e 1,14 segundos). Não houve significância no desfecho do teste nas avaliações inter-avaliadores (p=0,20). Conclusão: O AVD Glittre mostra-se reprodutível para a população hemiparética que o concluí aproximadamente em cinco minutos. Devido efeito aprendizado se faz necessário aplicação do teste e reteste.

Page generated in 0.0601 seconds