• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • Tagged with
  • 68
  • 68
  • 66
  • 64
  • 45
  • 22
  • 21
  • 21
  • 20
  • 18
  • 18
  • 16
  • 15
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comportamento celular na presença de materiais poliméricos em contato com dentina bovina hígida / Cell behavior in the presence of polymeric materials in contact with sound bovine dentin

Cotto, Ricardo Alfredo Carrillo 24 February 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-06T13:06:21Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Comportamento celular na presença de materiais poliméricos em contato com.pdf: 1901896 bytes, checksum: 9f5a355019ee540c11695dfcdc133773 (MD5) / Made available in DSpace on 2017-07-06T13:06:21Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Comportamento celular na presença de materiais poliméricos em contato com.pdf: 1901896 bytes, checksum: 9f5a355019ee540c11695dfcdc133773 (MD5) Previous issue date: 2017-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Os materiais poliméricos atualmente são muito utilizados em odontologia por terem várias vantagens sobre outros materiais de restauração no entanto, tem-se demonstrando a citotoxicidade dos compostos lixivados após sua polimerização. Assim o objetivo desta tese foi investigar a viabilidade celular dos queratinócitos quando em contato com diferentes tipos de materiais poliméricos restauradores na presença de dentina. Com o propósito de simular diferentes condições clínicas, foram confeccionadas diversas restaurações diretas e indiretas sobre discos de dentina bovina hígida. Iguais procedimentos foram realizados sobre placas de vidro até completar no total 14 grupos experimentais. O grau de conversão de cada um dos materiais foi avaliado. Clinicamente é provável que restaurações usando materiais poliméricos não exerçam considerável agressividade às células gengivais (HaCaT) uma vez que a dentina atua como fator protetor. Os seguintes materiis foram utilizados de acordo com as instruções dos fabricantes: OptiBond FL® (OB), Single Bond Universal® (SBU), Clearfil SE® (CSE), Dyad Flow® (DF), Filtek Z350XT® (Z350), Filtek Z350XT® Flow (FF), Dyad Flow® (DF), Variolink II® (VLII) and Rely U200® (U200). Foram testados três corpos-de-prova para cada grupo de materiais restauradores poliméricos (n=84). Os eludatos das restaurações foram obtidos da incubação das amostras após 1 e 7 dias em cultura celular à 37°C. Células HaCaT foram expostas aos eludatos durante 24 horas e 7 dias e posteriormente realizado o teste de viabilidade com MTT. As provas estatísticas para viabilidade celular mostraram que após o 1º dia o fator material e a interação entre fatores foram ambos significantes (p<0.001) sendo que a presença da dentina foi também um fator significante (p=0.023). Após 7 dias, ambos os fatores e sua interação foram significantes (p<0.001). As análises estatísticas para intervalo de confiança de 95% mostrou que não houve diferenças entre CSE e OB, entre DF, FF e U200, e entre SBU e Z350. Clinicamente, é provável que restaurações utilizando materiais poliméricos não exerçam considerável agressão às células gengivais HaCat. / Polymeric materials are currently widely used in dentistry because they have several advantages over other restorative materials however the cytotoxicity of the leached compounds has been demonstrated after their polymerization. Thus the aim of this thesis was to first investigate the cellular viability of keratinocytes when in contact with different types of restorative polymeric materials in the presence of dentin. The degree of conversion of each of the materials was also evaluated. Clinically is probably that restorations using polymeric materials do not exert considerable aggression to gingival (HaCaT) cells due dentin acts like a protection factor. In order to simulate different clinical conditions, different direct and indirect restorations were performed on dentin bovine disks. Same restorative procedures were performed on glass plates to obtain a total of 14 experimental groups. The following materials were used according to the manufacturers’ instructions: OptiBond FL® (OB), Single Bond Universal® (SBU), Clearfil SE® (CSE), Dyad Flow® (DF), Filtek Z350XT® (Z350), Filtek Z350XT® Flow (FF), Dyad Flow® (DF), Variolink II® (VLII) and Rely U200® (U200). Three specimens for each polymeric restorative materials group were tested (n=84). Restoration extracts were obtained from 1 and 7 days incubation of specimens in cell culture at 37°C. HaCaT keratinocytes were exposed to the extracts for 24h and 7 days and viability was assessed using the MTT assay. Statistics for cell viability after day 1 showed that the factor material and the interaction between factors were both significant (p<0.001) and the presence of dentin was also a significant factor (p=0.023). At day 7, both factors and their interaction were significant (p<0.001). Statistical analyses by 95% confidence interval showed that there was not difference between CSE and OB, among DF, FF and U200, between SBU and Z350. Clinically is probably that restorations using polymeric materials do not exert considerable aggression to gingival (HaCaT) cells
12

Avaliação da influência do material de confecção das matrizes no teste de conversão monomérica por espectrometria no infravermelho de um compósito / Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a composite

Adriana Riedlinger Mont'Alverne Bordalo 18 December 2007 (has links)
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante. / This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm. Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr. The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference.
13

Avaliação in vitro da correlação do manchamento extrínseco de compósitos resinosos com grau de conversão, rugosidade, sorção e solubilidade / In vitro evaluation of the correlation among extrinsic staining, degree of conversion, roughness, sorption and solubility of resin composite

Taciana Emília de Almeida Anfe 14 December 2012 (has links)
Nesta pesquisa in vitro verificou-se a possível correlação do manchamento superficial de resinas compostas com grau de conversão, rugosidade, sorção e solubilidade. Foram testados cinco compósitos: Charisma Opal, Filtek P90, GrandioSO, IPS Empress Direct e NDurance; todos da cor A2. Foram confeccionados 40 espécimes de cada material. Dez espécimes foram destinados aos testes de sorção e solubilidade, que foram divididos em dois grupos (n=5): Grupo 1 (com desidratação prévia) e Grupo 2 (sem desidratação prévia). Trinta espécimes foram destinados aos testes de grau de conversão, rugosidade e manchamento superficial; que foram divididos em dois grupos: Imediato e 24 horas. No grupo Imediato, a leitura do espectro para o cálculo do grau de conversão e a leitura da cor inicial (baseline) foram realizadas imediatamente após a confecção dos espécimes, que foram imersos nas bebidas corantes na sequência. No grupo 24 horas, os espécimes foram mantidos em água destilada a 37oC por 24 h. A leitura do espetro final para o cálculo do grau de conversão e a leitura da cor inicial (baseline) foram realizadas 24 h após a confecção dos espécimes, que só então foram imersos nas bebidas corantes. O polimento e a leitura da rugosidade foram realizados após a leitura do espectro e antes da imersão nas bebidas. Os espécimes foram divididos em três grupos (n=5): água destilada (controle), café e vinho tinto. A amostra foi mantida imersa nas bebidas por 7 dias, com temperatura em 37oC. A leitura da cor final foi realizada após esse período, em ambos os grupos. A diferença de cor foi calcula a partir da fórmula CIEDE2000. A análise estatística foi realizada e o teste de Pearson foi aplicado para a análise da correlação das propriedades testadas. De acordo com a metodologia utilizada neste estudo, não foi possível estabelecer correlação entre manchamento dos compósitos resinosos com grau de conversão, rugosidade superficial, sorção e solubilidade; não foi encontrada diferença no manchamento do grupo que foi submetido imediatamente às bebidas corantes com o grupo que foi submetido ao manchamento após 24 horas da sua confecção; o vinho tinto causou maior alteração de cor do que o café; e o comportamento dos compósitos na presença das bebidas corantes não foi semelhante. Além disso, não houve diferença significativa nas duas metodologias usadas para o teste de sorção e solubilidade. / This in vitro research verified the possible correlation of superficial staining of resin composites with degree of conversion, roughness, sorption and solubility. Five composites were tested: Charisma Opal, Filtek P90, GrandioSO, IPS Empress Direct and NDurance; shade A2. Forty specimens of each material were prepared. Ten specimens were reserved for sorption/solubility tests and were divided into 2 groups (n=5): Group 1 (with previous dehydration) and Group 2 (without previous dehydration). Thirty specimens were reserved for degree of conversion, roughness and staining tests; which were divided into 2 groups: Immediate and 24 hours. In Immediate group, degree of conversion and initial color measurement (baseline) were calculated immediately after sample preparation, which was immersed in coloring beverages. In 24 hours group, specimens were maintained in distilled water at 37oC for 24 h. Initial color measurement (baseline) and degree of conversion were calculated 24 h after sample preparation. Polishing and roughness measurement were made before the immersion of specimens in beverages. Sample was divided into 3 groups (n=5): distilled water (control), coffee and red wine. The specimens were maintained immersed for staining during 7 days at 37oC. Final color measurement was made after this period, in both groups. Color difference was calculated based on CIEDE2000 formula. Statistical analysis was performed and Pearson test was applied to analyze correlation between the properties tested. According to the methodology used in this research, it was not possible to establish correlation between composite staining and degree of conversion, roughness, sorption and solubility; it was not found any difference between Immediate and 24 hours groups; staining caused by red wine were more intense than coffee; the composites behavior in staining was not similar. Despite of this result, there was no significant difference between the sorption/solubility methods tested.
14

Avaliação do grau de conversão monomérica, parâmetros de cinética de polimerização e determinação de monômeros residuais em resinas experimentais / Evaluation of degree of monomer conversion, the polymerization kinetic parameters and determination of residual monomers in experimental resins

Aline Bassi Denis Bordini do Amaral 06 July 2012 (has links)
Este estudo teve como objetivo investigar múltiplos aspectos relacionados a polimerização da resina composta como: o grau de conversão monomérica (GC), parâmetros da cinética de polimerização e a determinação de monômeros residuais TEGDMA e BisGMA, além de avaliar o desempenho de aparelhos fotoativadores. As resinas compostas experimentais foram manipuladas variando-se os fotoiniciadores R1-) canforoquinona/amina, R2-) PPD/amina, R3-) PPD + canforoquinona/amina) e foram utilizados dois aparelhos para a fotoativação (I-) lâmpada halógena (Demetron LC/ SDS Kerr-USA) e II-) LED (Poly 600/Kavo-Brasil) ambos com 600 mW cm-2, por 40 s. O GC após 300 s e os parâmetros de cinética como taxa máxima de conversão (Rpmáx), tempo em que ocorreu a taxa máxima de polimerização (tmáx) e a conversão quando ocorreu a Rpmáx, foram determinados por meio de espectroscopia de absorção no infravermelho em tempo real (RT-FTIR), Os espectros foram coletados dos espécimes (n=5) no modo cinética, durante 305 s, entre 1680 e 1550 cm-1. As 5 primeiras varreduras coletadas serviram para fornecer o espectro de absorção da resina não polimerizada (utilizado no cálculo do GC). Na 6&ordm; varredura, o fotoativador foi ligado (por 40 segundos) enquanto o espectro continuava a ser coletado até 300 s após a ativação da luz. A presença de monômeros residuais (TEGDMA e BisGMA) foi avaliada por meio da cromatografia líquida de alta eficiência (HPLC), sendo que os espécimes (n=6) foram imersos em acetonitrila (5 mL-24 h) com agitação mecânica, o método desenvolvido utilizou: HPLC, coluna C18, fase móvel A: água com trietilamina (0,05%) acidificada com ácido acético (pH 4) e B: acetonitrila, modo de eluição com gradiente (40-85%-17 min/ 55&deg;C), fluxo de 1 mL min-1, detector UV em 210 nm, injeção de 20 &micro;L. Em relação aos resultados de GC após 300 s os maiores valores foram para a resina R1 tanto fotoativada com LED (65,90% &plusmn;1,81) quanto com a lâmpada halógena (64,40% &plusmn;0,83), e os menores valores encontrados foram quando a resina R2 foi fotoativada pelo LED (35,64% &plusmn;1,73) e a única resina que apresentou diferenças significantes em relação as fontes de luz foi a R2. Os valores da Rpmáx diminuíram nas resinas que apresentavam o fotoiniciador PPD. O tempo de ocorrência da taxa máxima de conversão (tmáx) aconteceu mais rapidamente para a resina com CQ. Todas as resinas apresentaram valores de grau de conversão similares no tmáx. Em relação aos resultados de HPLC, a quantidade de monômeros extraídos (M/M%) variou de 1,98% &plusmn;0,16 à 3,34% &plusmn;0,07 para os monômeros TEGDMA e de 3,57% &plusmn;0,30 à 7,57% &plusmn;0,40 para os monômeros BisGMA. A resina R2 apresentou a maior quantidade de monômeros residuais quando fotoativada com ambas as fontes, principalmente quando fotoativada com o LED. As resinas R1 e R3 obtiveram comportamento parecidos para ambos fotoativadores. Conclui-se que a resina R3 pode ser uma boa opção, pois quando comparada com a resina R1 apresentou vantagens como: redução na Rpmáx, bem como o momento em que esta ocorreu (tmáx), além de ser adequadamente fotoativada com aparelhos de LED. / This study aimed to investigate multiple aspects of composite resin polymerization as the degree of monomer conversion (DC), the kinetic parameters of polymerization and the determination of residual monomers TEGDMA and BisGMA, and evaluate the performance of light curing units. The experimental composites were manipulated by varying the photoinitiators R1-) camphorquinone/amine, R2-) PPD/amine, R3-) PPD + camphorquinone/ amine) and two devices were used for the polymerization I-) halogen lamp (Demetron LC / SDS Kerr, USA) and II-) LED (Poly 600/Kavo-Brasil) both with 600 mW cm-2 for 40 s. DC after 300 s and the kinetic parameters such as maximum rate of polymerization conversion (Rpmax), time of occurrence of the maximum rate of polymerisation (tmax) and the conversion occurred when Rpmax were determined by infrared absorption spectroscopy in real time (RT-FTIR), the infrared spectrum was collected from the specimen (n=5) in order kinetics for 305 s, between 1680 and 1550 cm-1. The first 5 scans were used to provide the collected absorption spectrum of the uncured resin (calculated DC). In the sixth scan, the curing unit was connected (by 40 seconds) while the spectrum continued to be collected up to 300 s after activation of the light. The presence of residual monomers (TEGDMA and BisGMA) was assessed by high performance liquid chromatography (HPLC), and the specimens (n=6) were immersed in acetonitrile (5 mL-24 h) with mechanical stirring, the method developed used: HPLC, C18 column, mobile phase A: water with triethylamine (0,05%) acidified with acetic acid (pH 4) and phase B: acetonitrile, gradient elution mode (40-85% -17 min/55 &deg;C), flow 1 mL/min, UV detector at 210 nm, injection of 20 &micro;L. Regarding the results of DC after 300s were the highest values for both R1 resin polymerized with LED (65.90% &plusmn;1.81) and with a halogen lamp (64.40% &plusmn;0.83), and lower values when the resin was found that R2 was polymerized by LED (35.64% &plusmn;1.73) and the only resin that showed significant differences in the sources of light was the R2. The values of the resins decreased Rpmax who had PPD photoinitiator. The time of occurrence of the maximum rate of conversion (tmax) occurred more rapidly for the resin with CQ. And all resins showed values similar degree of conversion in tmax. For HPLC results, the amount of monomer extracted (M/M%) ranged from 1.98% &plusmn;0.16 to 3.34% &plusmn;0.07 for the monomers of TEGDMA and 3.57% &plusmn;0.30 to 7.57% &plusmn;0.40 for the monomers BisGMA. Resin R2 showed the highest amount of residual monomers as polymerized with both sources, especially when polymerized with LED. Resins R1 and R3 had similar behavior for both curing units. In conclusion, the resin R3 can be a good choice, as compared with the resin obtained R1 advantages as reduction in Rpmax as well as the time it occurred (tmax), and be suitably photoactivated with LED devices.
15

Influência do modo de ativação e de uma restauração simulada de porcelana no grau de conversão e na dureza superficial de um cimento resinoso auto-adesivo de cura dual / Influence of polymerization mode and a simulated ceramic restoration on degree of conversion and surface hardness of a dual-cured self-adhesive resin cement

Irma Cunha Matos 28 February 2008 (has links)
Este estudo objetivou analisar o grau de conversão (GC) e a microdureza de um cimento resinoso utilizando diferentes protocolos de ativação, e, caracterizar o cimento quanto à composição monomérica, diâmetro médio das partículas inorgânicas e porcentagem em peso das frações orgânica e inorgânica. Foram preparados quarenta espécimes (8mm de diâmetro, 0,5mm de espessura), sendo metade usada para a determinação do GC e a outra metade usada no teste de microdureza. Os espécimes foram divididos em quatro grupos: GR1 fotoativação realizada diretamente sobre o cimento por 20s, GR2 fotoativação através de um disco de porcelana com 2mm de espessura por 20s, GR3 fotoativação através de um disco de porcelana com 2mm de espessura por 40s, e GR4 fotoativação foi omitida e o material foi polimerizado exclusivamente por seus componentes químicos. A dureza Vickers (HV) e o GC, determinado através de FTIR-ATR, foram realizados imediatamente após a fotoativação (GR1, GR2 e GR3) ou cinco minutos após o início da polimerização (GR4). Após armazenagem em ambiente seco e escuro por 24h, os espécimes foram novamente submetidos aos testes de HV e GC. Para a caracterização do material avaliado, foram realizadas as análises: Termogravimétrica, Espectrometria no Infravermelho, Espectrometria de Ressonância Magnética Nuclear e Microscopia Eletrônica de Varredura. Os resultados foram analisados estatisticamente por ANOVA, teste t e teste de Bonferroni (P&#8804;0,05). Os valores do GC nos períodos imediato e 24h foram, respectivamente: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. Os valores de HV nos períodos imediato e 24h foram, respectivamente: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. A baixa polimerização para o GR4 não permitiu a determinação da dureza inicial e após 24h este valor foi 10.65HV 0.92. O modo de ativação autopolimerizável influenciou negativamente o GC e a HV em relação ao modo de ativação no qual foi utilizada a fotoativação. A restauração simulada de porcelana não influenciou o GC, porém interferiu negativamente na microdureza. O tempo de fotoativação não influenciou os valores do GC e da HV. O GC e microdureza sofreram um aumento significativo após 24h da polimerização inicial, com exceção do GC no período inicial, quando a fotoativação foi realizada através de um disco de porcelana por um tempo de exposição de 20s. Houve uma correlação linear e positiva entre a HV e o GC para o cimento RelyX&#61668; Unicem. Caracterização química: porção orgânica composta por uma mistura de monômeros, tendo o Bis-GMA como monômero-base. Presença de um monômero dimetacrilato contendo hidroxila para se ligar ao ácido fosfórico sob a forma de fosfato. Partículas inorgânicas variando entre 0,4 a 11,2&#61549;m. A fração sólida do material é composta por 96% de partículas inorgânicas. Na fração líquida, a porção orgânica corresponde a 84%. Restou um resíduo incombustível de 16% devido à queima do material em atmosfera de nitrogênio. / The aim of this study was to evaluate the degree of conversion (DC) and the microhardness of a self-adhesive resin cement under different activation protocols, immediately and after 24 hours of the beginning of the polymerization, and, defining cement regarding monomer composition, average diameter of the inorganic fillers and the percentage by weight of the organic and inorganic portions. Forty specimens (8 mm in diameter, 0.5 mm in height) were prepared. Half of them were used to determine DC and the other half were used on the microhardness test. The specimens were divided into four groups: GR1 direct photoactivation for 20s, GR2 photoactivation through 2mm porcelain disc for 20s, GR3 photoactivation through 2 mm porcelain disc for 40 s, and GR4 photoactivation was omitted and curing was reliant on the chemical reaction only. Vickers microhardness (HV) and DC, by FTIR-ATR, were determined immediately after photoactivation (GR1, GR2 e GR3) or after five minutes from the beginning of the polymerization (GR4). After dry storage in the dark, for 24 hours, the samples were submitted to the tests again. In order to define the studied cement, the Thermogravimetric method was applied, as well as the Infrared Spectometry, Nuclear Magnetic Ressonance Spectroscopy and Scanning Electron Microscope. Data were statistically analyzed by one-way ANOVA, t-Test and Bonferroni Test (P&#8804;0,05) and the degree of conversion values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. HV values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. The low DC for GR4 do not permitted to quantify the initial HV value and after 24 hours this values was 10.65HV 0.92. The chemical curing mode showed DC and HV results for both period (initial and after 24 hours), statistically lower than the other groups where the photoactivation was used. The simulated ceramic restoration did not influence monomer conversion, however it negatively influence resin cement hardness. The exposure time did not influence resin cement hardness and monomer conversion. The inical DC and HV were significantly greater than after 24 hours, except for DC for initial period, when the photoactivation was realizded through a porcelain disc for 20s.There was a linear and positive correlation between degree of conversion and microhadness for the self-adhesive resin cement RelyX&#61668; Unicem. Defining the cement: organic portion composed by a mixture of monomers. Bis-GMA is the main monomer. Presence of a dimethacrylate containing hydroxyl to connect to the phosphoric acid as a phosphate. Inorganic fillers raging between 0,4 to 11,2&#61549;m. Powder is composed by 96% of inorganic particles. In liquid fraction, the organic portion corresponds to 84%. There were 16% of waste that did not burn due to nitrogen atmosphere.
16

Estudo do grau de conversão e dureza em compósitos odontológicos fotopolimerizáveis

Menegazzo, Lívia Maluf [UNESP] 22 May 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-05-22Bitstream added on 2014-06-13T19:12:25Z : No. of bitstreams: 1 menegazzo_lm_me_ilha.pdf: 652340 bytes, checksum: 7cd3c65c7db0577bbe66236ac50269ff (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho propõe o estudo do grau de conversão e de dureza de três resinas fotoativadas Fill Magic, TPH Spectrum e Te-Econom, em função do tempo de exposição e do tipo de fonte de luz. Foram utilizadas quatro fontes diferentes, sendo duas halógenas e duas baseadas em LED. O grau de conversão foi avaliado de espectros de absorção no infravermelho próximo e a dureza através de testes Vickers. Cinco amostras de 10 mm de diâmetro e 2 mm de espessura foram preparadas para cada tempo de exposição e tipo de fonte. Após exposição à luz, todas as amostras foram mantidas durante 7 dias em ambiente escuro antes de serem utilizadas para obtenção de espectros e serem submetidas ao teste de dureza. Os espectros foram obtidos em um espectrômetro Nexus 670 da Nicolet e a microdureza Vickers foi obtida com um microdurômetro HMV - 2T da Shimadzu. Os resultados mostraram que o grau de conversão aumenta com o tempo de exposição para fontes com densidade de potência menor que 233 mW/cm2. Não foi observada diferença significativa no grau de conversão nas amostras irradiadas com fontes halógena e LED, ambas com densidade de potência maior que 233 mW/cm2. Não foi possível estabelecer uma relação entre dureza e o tempo de exposição ou a densidade de potência. Entre as resinas, a FM é a que apresentou melhores valores de grau de conversão e a Te-Econom de dureza. / The aim of this study was to evaluate the degree of conversion and hardness of three photo-activated composites (Fill Magic, TPH Spectrum and Te-Econom) as a function of exposure time and type of light source. As visible light source were utilized four different units, two halogen and two light-emitting diodes (LED). The conversion degree was evaluated by near-infrared spectroscopy and the hardness by Vickers tests. Five samples of 10 mm diameter and 2 mm thickness were prepared for each exposure time and light source. The spectra were obtained in a Nexus 670 Nicolet spectrometer and the hardness in a HMV - 2T micro hardness tester (Shimadzu). These measurements were performed after 7 days dark storage. The results showed that the degree of conversion increases with the exposure time for the light units with power density smaller than 233 mW/cm2. No significant differences were observed in degree of conversion in samples irradiated with halogen and LED units, both with power density larger than 233 mW/cm2. There is not correlation between the conversion degree and the micro hardness for all studied composites. The highest values for conversion degree and hardness were obtained with the Fill Magic and Te-Econom composites, respectively.
17

Adesão e grau de conversão: efeito das cores da cerâmica e do agente de fixação resinoso

Passos, Sheila Pestana [UNESP] 18 October 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-10-18Bitstream added on 2014-06-13T20:45:49Z : No. of bitstreams: 1 passos_sp_dr_sjc.pdf: 3848792 bytes, checksum: 3fb1f1393e2dc87d50d66555ecfbb5ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a translucidez de diferentes cores da cerâmica, o grau de conversão de diferentes cores do agente de fixação resinoso e a resistência de união entre a cerâmica e a dentina, variando as cores da cerâmica e do agente de fixação e o tempo de fotoativação. A hipótese é que quanto mais escuros o agente de fixação resinoso e a cerâmica, menor translucidez, menor conversão dos monômeros, mais baixa será a resistência adesiva, portanto maior tempo necessário para fotoativação. Três discos da cerâmica Vita VM7 com dimensão de 20 x 2 mm nas cores Base Dentine 0M1, Base Dentine 2M2 e Base Dentine 5M3 e dois discos com 20 x 2,5 mm da mesma cerâmica nas cores Base Dentine 0M1 e Base Dentine 5M3 foram usados para determinar a percentagem de translucidez através do espectrofotômetro MiniScan. Para se obter o grau de conversão (GC), os cp do agente de fixação (Variolink II; A3 Amarelo e transparente; espessura: 100 μm) foram fotoativados sob um bloco cerâmico (espessura: 2 mm; Base Dentine 0M1, Base Dentine 2M2 e Base Dentine 5M3) por 20 ou 40 s. Cp fotoativados sem o bloco cerâmico foram usados como controle. Dezesseis grupos (n=3) foram avaliados. Espectrometria de Micro- ATR/FTIR foi utilizada para avaliar a extensão da polimerização de todos os cp depois de 24 h. A %GC foi calculada e os dados foram analisados através de ANOVA 1-fator e teste de Tukey ( =0,05). Para avaliar adesão, a dentina da superfície oclusal de 80 molares humanos hígidos foi exposta e condicionada com ácido fosfórico 37% e adesivo (Excite DSC). Oitenta blocos (7,2 x 7,2 x 2,5 mm) da mesma cerâmica, nas cores Base Dentine 0M1 e Base Dentine 5M3, foram confeccionados de acordo com as instruções do fabricante. A superfície cerâmica foi tratada com ácido fluorídrico 10% por 60 s e silanizada. Os blocos cerâmicos de cada cor foram cimentados... / The aim of this study was to evaluate the translucency of different ceramic shades, degree of conversion of different resin cement and the bond strength between a feldspathic ceramic and dentin using different resin cement and ceramic shades, and the activation time. The hypothesis is the darker the resin cement and ceramic, lower the translucency; the lower the degree of monomers conversion, lower the bond strength, then the activation time should be higher. Three discs of Vita VM7 ceramic with 20 x 2 mm and shades: Base Dentine 0M1, Base Dentine 2M2 and Base Dentine 5M3, and two discs with 20 x 2.5 mm of the same ceramic and shades: Base Dentine 0M1 and Base Dentine 5M3 were used to determine the translucency percentage of each sp using the MiniScan espectrophotometer. For measure the degree of conversion (DC), the resin cement (Variolink II; A3 Yellow and transparent) specimens (thickness: 100 μm) were photocured under a ceramic block (2mm-thick; Base Dentine 0M1, Base Dentine 2M2 and Base Dentine 5M3) for 20 or 40 s. Specimen photocured without the ceramic block were used as control. Sixteen groups (n=3) were evaluated. Micro-ATR/FTIR spectrometry was used to evaluate the extent of polymerization of all sp after 24 h. The %DC was calculated and the data were analyzed using ANOVA 1-way and Tukey test ( =0,05). For the microtensile bond strength test, the occlusal dentin surface of eighty molars were exposed and etched with 37% phosphoric acid and an adhesive (Excite DSC) was applied. Eighty blocks (7.2 x 7.2 x 2.5 mm) of Base Dentine 0M1 and Base Dentine 5M3 of Vita VM7 ceramic were produced according to the manufacturers. The ceramic surface was etched with 10% hydrofluoric acid for 60 s, followed by the application of a silane agent and a dualcured resin cement (Variolink II; base and catalyst: A3 Yellow; base and catalyst: transparent), according to the manufacturers’ ...(Complete abstract click electronic access below)
18

Influência do modo de ativação e de uma restauração simulada de porcelana no grau de conversão e na dureza superficial de um cimento resinoso auto-adesivo de cura dual / Influence of polymerization mode and a simulated ceramic restoration on degree of conversion and surface hardness of a dual-cured self-adhesive resin cement

Irma Cunha Matos 28 February 2008 (has links)
Este estudo objetivou analisar o grau de conversão (GC) e a microdureza de um cimento resinoso utilizando diferentes protocolos de ativação, e, caracterizar o cimento quanto à composição monomérica, diâmetro médio das partículas inorgânicas e porcentagem em peso das frações orgânica e inorgânica. Foram preparados quarenta espécimes (8mm de diâmetro, 0,5mm de espessura), sendo metade usada para a determinação do GC e a outra metade usada no teste de microdureza. Os espécimes foram divididos em quatro grupos: GR1 fotoativação realizada diretamente sobre o cimento por 20s, GR2 fotoativação através de um disco de porcelana com 2mm de espessura por 20s, GR3 fotoativação através de um disco de porcelana com 2mm de espessura por 40s, e GR4 fotoativação foi omitida e o material foi polimerizado exclusivamente por seus componentes químicos. A dureza Vickers (HV) e o GC, determinado através de FTIR-ATR, foram realizados imediatamente após a fotoativação (GR1, GR2 e GR3) ou cinco minutos após o início da polimerização (GR4). Após armazenagem em ambiente seco e escuro por 24h, os espécimes foram novamente submetidos aos testes de HV e GC. Para a caracterização do material avaliado, foram realizadas as análises: Termogravimétrica, Espectrometria no Infravermelho, Espectrometria de Ressonância Magnética Nuclear e Microscopia Eletrônica de Varredura. Os resultados foram analisados estatisticamente por ANOVA, teste t e teste de Bonferroni (P&#8804;0,05). Os valores do GC nos períodos imediato e 24h foram, respectivamente: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. Os valores de HV nos períodos imediato e 24h foram, respectivamente: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. A baixa polimerização para o GR4 não permitiu a determinação da dureza inicial e após 24h este valor foi 10.65HV 0.92. O modo de ativação autopolimerizável influenciou negativamente o GC e a HV em relação ao modo de ativação no qual foi utilizada a fotoativação. A restauração simulada de porcelana não influenciou o GC, porém interferiu negativamente na microdureza. O tempo de fotoativação não influenciou os valores do GC e da HV. O GC e microdureza sofreram um aumento significativo após 24h da polimerização inicial, com exceção do GC no período inicial, quando a fotoativação foi realizada através de um disco de porcelana por um tempo de exposição de 20s. Houve uma correlação linear e positiva entre a HV e o GC para o cimento RelyX&#61668; Unicem. Caracterização química: porção orgânica composta por uma mistura de monômeros, tendo o Bis-GMA como monômero-base. Presença de um monômero dimetacrilato contendo hidroxila para se ligar ao ácido fosfórico sob a forma de fosfato. Partículas inorgânicas variando entre 0,4 a 11,2&#61549;m. A fração sólida do material é composta por 96% de partículas inorgânicas. Na fração líquida, a porção orgânica corresponde a 84%. Restou um resíduo incombustível de 16% devido à queima do material em atmosfera de nitrogênio. / The aim of this study was to evaluate the degree of conversion (DC) and the microhardness of a self-adhesive resin cement under different activation protocols, immediately and after 24 hours of the beginning of the polymerization, and, defining cement regarding monomer composition, average diameter of the inorganic fillers and the percentage by weight of the organic and inorganic portions. Forty specimens (8 mm in diameter, 0.5 mm in height) were prepared. Half of them were used to determine DC and the other half were used on the microhardness test. The specimens were divided into four groups: GR1 direct photoactivation for 20s, GR2 photoactivation through 2mm porcelain disc for 20s, GR3 photoactivation through 2 mm porcelain disc for 40 s, and GR4 photoactivation was omitted and curing was reliant on the chemical reaction only. Vickers microhardness (HV) and DC, by FTIR-ATR, were determined immediately after photoactivation (GR1, GR2 e GR3) or after five minutes from the beginning of the polymerization (GR4). After dry storage in the dark, for 24 hours, the samples were submitted to the tests again. In order to define the studied cement, the Thermogravimetric method was applied, as well as the Infrared Spectometry, Nuclear Magnetic Ressonance Spectroscopy and Scanning Electron Microscope. Data were statistically analyzed by one-way ANOVA, t-Test and Bonferroni Test (P&#8804;0,05) and the degree of conversion values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. HV values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. The low DC for GR4 do not permitted to quantify the initial HV value and after 24 hours this values was 10.65HV 0.92. The chemical curing mode showed DC and HV results for both period (initial and after 24 hours), statistically lower than the other groups where the photoactivation was used. The simulated ceramic restoration did not influence monomer conversion, however it negatively influence resin cement hardness. The exposure time did not influence resin cement hardness and monomer conversion. The inical DC and HV were significantly greater than after 24 hours, except for DC for initial period, when the photoactivation was realizded through a porcelain disc for 20s.There was a linear and positive correlation between degree of conversion and microhadness for the self-adhesive resin cement RelyX&#61668; Unicem. Defining the cement: organic portion composed by a mixture of monomers. Bis-GMA is the main monomer. Presence of a dimethacrylate containing hydroxyl to connect to the phosphoric acid as a phosphate. Inorganic fillers raging between 0,4 to 11,2&#61549;m. Powder is composed by 96% of inorganic particles. In liquid fraction, the organic portion corresponds to 84%. There were 16% of waste that did not burn due to nitrogen atmosphere.
19

Avaliação da influência do material de confecção das matrizes no teste de conversão monomérica por espectrometria no infravermelho de um compósito / Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a composite

Adriana Riedlinger Mont'Alverne Bordalo 18 December 2007 (has links)
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante. / This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm. Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr. The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference.
20

"InfluÃncia dos protocolos de fotoativaÃÃo na microdureza e no grau de conversÃo de uma resina composta" / "Influence of curing protocols on microhardness and degree of conversion of a composite resin"

AndrÃa GalvÃo Marinho Bomfim 02 October 2009 (has links)
FundaÃÃo de Amparo à Pesquisa do Estado do Cearà / O objetivo deste trabalho foi avaliar in vitro o grau de conversÃo da resina composta Filtek Z 350 (3M ESPE), na cor A3, empregando a luz halÃgena pelo aparelho VIP (Variable Intensity Polymerizer) JÃnior (Bisco), utilizando trÃs protocolos de fotoativaÃÃo, a saber: convencional 500mW/cm por 40s; gradual 300mW/cm por 3s e, em seguida, 500mW/cm por 30s; pulso tardio 300mW/cm por 3s, com pausa de 3 min; e 300mW/cm por 30s. O grau de conversÃo da resina foi obtido atravÃs do teste de microdureza Knoop e espectrografia Raman. Uma matriz metÃlica, bipartida, com orifÃcio central de 2,5mm de profundidade e 5mm de diÃmetro, foi utilizada para confecÃÃo dos corpos de prova, que foram fotoativados segundo os protocolos descritos. Foram confeccionados cinco corpos de prova de cada tipo de protocolo para o ensaio de microdureza e uma amostra de cada protocolo para o teste de Raman. Os testes foram realizados 24 horas apÃs a polimerizaÃÃo dos corpos de prova, que foram armazenados a seco, ao abrigo da luz e à temperatura ambiente. Na microdureza, cinco indentaÃÃes foram realizadas em cada superfÃcie (topo e base) do corpo de prova com uma carga de 10gf por 10s. O Raman foi realizado no centro da amostra do topo e da base. Os resultados obtidos foram submetidos à AnÃlise de VariÃncia a 2 critÃrios e ao teste de comparaÃÃes mÃltiplas de Student-Newman-Keuls, a um nÃvel de significÃncia de 5%. Pode-se observar que houve diferenÃas estatisticamente significantes entre os protocolos de fotoativaÃÃo utilizados, quando a anÃlise foi realizada no topo dos espÃcimes, sendo que a fotoativaÃÃo convencional apresentou os maiores valores de dureza. Entretanto, quando a mensuraÃÃo da dureza foi realizada na extremidade oposta dos espÃcimes (base), nÃo foram observadas diferenÃas estatisticamente significantes entre os protocolos de fotoativaÃÃo. Contudo, nas comparaÃÃes entre os valores de dureza observados em relaÃÃo à localizaÃÃo da mensuraÃÃo (topo ou base), pode-se observar que os valores obtidos no topo dos espÃcimes foram estatisticamente superiores aos observados na base dos mesmos, com exceÃÃo do protocolo pulso tardio, onde nÃo houve diferenÃa estatÃsticamente significante ente as superfÃcies do topo e da base. O teste de Raman confirmou os resultados achados na microdureza, com o grau de conversÃo da resina, sendo maior nas superfÃcies de topo e com maior conversÃo dos protocolos convencional e soft start. / This study evaluate the degree of conversion of composite resin Filtek Z 350 (3M ESPE), on shade A3, using halogen light VIP (Variable Intensity Polymerizer) Junior (Bisco) utilizing three light curing protocols, they are: standard 500mW/cm by 40 sec; soft start 300mW/cm by 3 sec and after 500mW/cm by 30 sec; pulse delay 300mW/cm by 3 sec, stop by 3 min and 100mW/cm by 30 sec. The degree of conversion of the resin was analyzed by the test of microhardness Knoop and Raman spectrography. Five samples of each type of protocol for the microhardness test had been confectioned and one sample of each protocol for the test of Raman. The tests had been made 24 hours after the polymerization of the samples, that had been stored the dry one, protected from the light and at room temperature. In the microhardness, five indentations had been made in each surface (top and bottom) of the sample with a load of 10gf for 10s. The Raman was obtained from the center of the sample of the top and the bottom surfaces. The results had been submitted the Two-Way ANOVA and to the test of multiple comparisons of Student-Newman-Keuls, to a level of significance of 5%. It can be observed that it had statistical significant differences between the used curing protocols when the analysis was made in the top of specimens, being that the standard curing protocol presented biggest values of hardness. However, when the value of the hardness was obtained from in the opposing extremity of specimens (bottom), statistical significant differences between the curing protocols had not been observed. In the comparisons between the values of hardness observed in relation to the localization of the indentation, it can be observed independently that the values obtained in the top of specimens had been statistical differences, with exception for the protocol pulse delay, where had not significant statistical difference between the surfaces of top and bottom. The test of Raman confirmed the results finds in the microhardness, with the degree of conversion of resin higher in top surface, and with bigger degree of conversion of the conventional and soft start protocols.

Page generated in 0.087 seconds