• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de procedimentos analíticos rápidos para o controle de qualidade de biodiesel / Fast analytical procedures for biodiesel quality control

Soares, Samara 05 March 2018 (has links)
A presente dissertação apresenta os resultados referentes ao desenvolvimento de procedimentos analíticos para a determinação de índice de iodo em biodiesel e óleo vegetal e do teor de éster em biodiesel e em misturas biodiesel:diesel. O primeiro procedimento para a determinação de índice de iodo foi baseado na descoloração de uma solução de I3- monitorada por espectrofotometria. Para amostras de biodiesel e óleo vegetal, foram obtidas respostas lineares nos intervalos de 10-106 g I2/100 g e 20-144 g I2/100 g, respectivamente. O coeficiente de variação (n = 10) e o limite de detecção (99,7% nível de confiança) foram estimados em 5,0% e 2,5 g I2/100 g para amostras de biodiesel, enquanto para amostras de óleos vegetais os valores foram 3,0% e 7 g I2/100 g, respectivamente. Foram consumidos ca. 1,2 mL de amostra, 0,365 mg de I2 e 40 mg de KI, e gerado ca. 2,2 mL de resíduo por determinação. Efeitos de matriz foram constatados e superados por calibração com compatibilização de matriz. Alternativamente, foi desenvolvimento um spot test utilizando imagens digitais, também baseado no consumo de I2 pelos compostos insaturados presentes na amostra, porém envolvendo a deposição de alíquotas de reagente em papel de filtro e a medida do I2 remanescente, na forma do complexo com amido. As medidas foram realizadas com a câmera de um celular e tratadas como reflectância. Resposta linear foi obtida entre 10-106 g I2/100 g de biodiesel, com coeficiente de variação (n = 10) e limite de detecção (99,7% nível de confiança) estimados em 5,0% e 8 g I2/100 g, respectivamente. Foram consumidos 40 ?L de amostra e 50 ?g de I2 e gerado 65 ?L de resíduo por determinação. A determinação do teor de éster baseou-se na formação do complexo violeta entre Fe(III) e hidroxamato, gerado pela reação entre os ésteres de alquila da amostra e hidroxilamina. Foi utilizado um sistema de análises de fluxo, explorando o processo lab-in-syringe, com etanol como solvente mediador para gerar uma única fase entre a amostra hidrofóbica e os reagentes hidrofílicos. Respostas lineares foram obtidas nos intervalos 4-99% (v/v) e 2-40% (v/v) para biodiesel e mistura biodiesel:diesel, respectivamente. Para as amostras de biodiesel, o coeficiente de variação, o limite de detecção e a frequência de amostragem foram estimados em 0,80% (n = 10), 0,36% e 15 h-1, respectivamente, enquanto para a mistura biodiesel:diesel foram 0,20%, 0,03% (v/v) e 12 h-1, respectivamente. Foram consumidos 40 ?L de amostra de biodiesel e 100 ?L da mistura biodiesel:diesel, 0,860 mg de hidroxilamina, 0,145 mg Fe e gerado ca. 3 mL de resíduo. Os resultados obtidos em todos os procedimentos foram concordantes com os obtidos em procedimentos de referência com 95% de confiança. Os procedimentos desenvolvidos são práticos e viáveis para análises on-line e at-line, além de consumirem pequenas quantidades de solventes orgânicos e reagentes e gerarem pequenos volumes de resíduos / The present dissertation is focused on the development of analytical procedures for the determination of iodine value in biodiesel and vegetable oils as well as of ester content in biodiesel and biodiesel:diesel blends. The procedure for the determination of iodine value was based on discoloration of a triiodide solution measured by spectrophotometry. For biodiesel and vegetable oil samples, linear responses were obtained from 10-106 g I2/100 g and 20-144 g I2/100 g, respectively. The coefficient of variation (n = 10) and limit of detection (99.7% confidence level) were 5.0% and 2.5 g I2/100 g, whereas for vegetable oils, the values were 3.0% and 7 g I2/100 g, respectively. About 1.2 mL of sample, 0.365 mg of I2 and 40 mg of KI were consumed per determination, with generation of ca. 2.2 mL of waste. Matrix effects were circumvented by matrix matching. Alternatively, a spot test using digital images was developed, also based on consumption of iodine by unsaturated compounds in the samples, but relying on deposition of reagent aliquots on a filter paper followed by measurement of remaining iodine, through its complex formed with starch. The measurements were performed with a cell phone camera and treated as reflectance. A linear response was obtained within 10 and 106 g I2/100 g of biodiesel. The coefficient of variation (n = 10) and limit of detection were (99.7% confidence level) estimated at 4.9% and 8 g I2/100 g, respectively. About 40 ?L of sample and 50 ?g of I2 were consumed per determination, with generation of ca. 65 ?L of waste per determination. Ester determination was based on reaction of alkyl esters from biodiesel and hydroxylamine, yielding hydroxamate, which was measured by spectrophotometry as an iron(III) complex. The flow-based procedure exploited the lab-in-syringe approach, by using ethanol as mediator solvent to generate a single phase between the hydrophobic sample and the hydrophilic reagents. Linear responses were obtained from 4 to 99% (v/v) and 2 to 40% (v/v) for biodiesel and biodiesel:diesel blends, respectively. For biodiesel samples the coefficient of variation (n = 10), detection limit (99.7% confidence level) and sampling rate were estimated at 0.80%, 0.36%, and 15 h-1, respectively, whereas for biodiesel:diesel blends, the corresponding values were 0.20%, 0.03% (v/v), and 12 h-1, respectively. About 40 µL of biodiesel or 100 µL biodiesel:diesel blends, 0.860 mg of hydroxylamine, and 0.145 mg Fe were consumed per determination, with generation of ca. 3 mL of waste. The results obtained by all the proposed procedures agreed with the reference ones at the 95% confidence level. The proposed procedures are practical and feasible for on-line or at-line analysis, by consuming only low amounts of organic solvents and reagents, and generating low waste volumes
2

Desenvolvimento de procedimentos analíticos rápidos para o controle de qualidade de biodiesel / Fast analytical procedures for biodiesel quality control

Samara Soares 05 March 2018 (has links)
A presente dissertação apresenta os resultados referentes ao desenvolvimento de procedimentos analíticos para a determinação de índice de iodo em biodiesel e óleo vegetal e do teor de éster em biodiesel e em misturas biodiesel:diesel. O primeiro procedimento para a determinação de índice de iodo foi baseado na descoloração de uma solução de I3- monitorada por espectrofotometria. Para amostras de biodiesel e óleo vegetal, foram obtidas respostas lineares nos intervalos de 10-106 g I2/100 g e 20-144 g I2/100 g, respectivamente. O coeficiente de variação (n = 10) e o limite de detecção (99,7% nível de confiança) foram estimados em 5,0% e 2,5 g I2/100 g para amostras de biodiesel, enquanto para amostras de óleos vegetais os valores foram 3,0% e 7 g I2/100 g, respectivamente. Foram consumidos ca. 1,2 mL de amostra, 0,365 mg de I2 e 40 mg de KI, e gerado ca. 2,2 mL de resíduo por determinação. Efeitos de matriz foram constatados e superados por calibração com compatibilização de matriz. Alternativamente, foi desenvolvimento um spot test utilizando imagens digitais, também baseado no consumo de I2 pelos compostos insaturados presentes na amostra, porém envolvendo a deposição de alíquotas de reagente em papel de filtro e a medida do I2 remanescente, na forma do complexo com amido. As medidas foram realizadas com a câmera de um celular e tratadas como reflectância. Resposta linear foi obtida entre 10-106 g I2/100 g de biodiesel, com coeficiente de variação (n = 10) e limite de detecção (99,7% nível de confiança) estimados em 5,0% e 8 g I2/100 g, respectivamente. Foram consumidos 40 ?L de amostra e 50 ?g de I2 e gerado 65 ?L de resíduo por determinação. A determinação do teor de éster baseou-se na formação do complexo violeta entre Fe(III) e hidroxamato, gerado pela reação entre os ésteres de alquila da amostra e hidroxilamina. Foi utilizado um sistema de análises de fluxo, explorando o processo lab-in-syringe, com etanol como solvente mediador para gerar uma única fase entre a amostra hidrofóbica e os reagentes hidrofílicos. Respostas lineares foram obtidas nos intervalos 4-99% (v/v) e 2-40% (v/v) para biodiesel e mistura biodiesel:diesel, respectivamente. Para as amostras de biodiesel, o coeficiente de variação, o limite de detecção e a frequência de amostragem foram estimados em 0,80% (n = 10), 0,36% e 15 h-1, respectivamente, enquanto para a mistura biodiesel:diesel foram 0,20%, 0,03% (v/v) e 12 h-1, respectivamente. Foram consumidos 40 ?L de amostra de biodiesel e 100 ?L da mistura biodiesel:diesel, 0,860 mg de hidroxilamina, 0,145 mg Fe e gerado ca. 3 mL de resíduo. Os resultados obtidos em todos os procedimentos foram concordantes com os obtidos em procedimentos de referência com 95% de confiança. Os procedimentos desenvolvidos são práticos e viáveis para análises on-line e at-line, além de consumirem pequenas quantidades de solventes orgânicos e reagentes e gerarem pequenos volumes de resíduos / The present dissertation is focused on the development of analytical procedures for the determination of iodine value in biodiesel and vegetable oils as well as of ester content in biodiesel and biodiesel:diesel blends. The procedure for the determination of iodine value was based on discoloration of a triiodide solution measured by spectrophotometry. For biodiesel and vegetable oil samples, linear responses were obtained from 10-106 g I2/100 g and 20-144 g I2/100 g, respectively. The coefficient of variation (n = 10) and limit of detection (99.7% confidence level) were 5.0% and 2.5 g I2/100 g, whereas for vegetable oils, the values were 3.0% and 7 g I2/100 g, respectively. About 1.2 mL of sample, 0.365 mg of I2 and 40 mg of KI were consumed per determination, with generation of ca. 2.2 mL of waste. Matrix effects were circumvented by matrix matching. Alternatively, a spot test using digital images was developed, also based on consumption of iodine by unsaturated compounds in the samples, but relying on deposition of reagent aliquots on a filter paper followed by measurement of remaining iodine, through its complex formed with starch. The measurements were performed with a cell phone camera and treated as reflectance. A linear response was obtained within 10 and 106 g I2/100 g of biodiesel. The coefficient of variation (n = 10) and limit of detection were (99.7% confidence level) estimated at 4.9% and 8 g I2/100 g, respectively. About 40 ?L of sample and 50 ?g of I2 were consumed per determination, with generation of ca. 65 ?L of waste per determination. Ester determination was based on reaction of alkyl esters from biodiesel and hydroxylamine, yielding hydroxamate, which was measured by spectrophotometry as an iron(III) complex. The flow-based procedure exploited the lab-in-syringe approach, by using ethanol as mediator solvent to generate a single phase between the hydrophobic sample and the hydrophilic reagents. Linear responses were obtained from 4 to 99% (v/v) and 2 to 40% (v/v) for biodiesel and biodiesel:diesel blends, respectively. For biodiesel samples the coefficient of variation (n = 10), detection limit (99.7% confidence level) and sampling rate were estimated at 0.80%, 0.36%, and 15 h-1, respectively, whereas for biodiesel:diesel blends, the corresponding values were 0.20%, 0.03% (v/v), and 12 h-1, respectively. About 40 µL of biodiesel or 100 µL biodiesel:diesel blends, 0.860 mg of hydroxylamine, and 0.145 mg Fe were consumed per determination, with generation of ca. 3 mL of waste. The results obtained by all the proposed procedures agreed with the reference ones at the 95% confidence level. The proposed procedures are practical and feasible for on-line or at-line analysis, by consuming only low amounts of organic solvents and reagents, and generating low waste volumes
3

[en] ANALYTICAL METHODS BASED ON PHOTOCHEMICALLY INDUCED FLUORESCENCE: SPECTROFLUORIMETRIC AND CHROMATOGRAPHIC APPLICATIONS FOR THE DETERMINATION OF TETRABENAZINE, AMITRIPTYLINE AND VARENICLINE / [pt] MÉTODOS ANALÍTICOS BASEADOS NA INDUÇÃO FOTOQUÍMICA DE FLUORESCÊNCIA: APLICAÇÕES ESPECTROFLUORIMÉTRICAS E CROMATOGRÁFICAS PARA A DETERMINAÇÃO DE TETRABENAZINA, AMITRIPTILINA E VARENICLINA

27 December 2021 (has links)
[pt] A derivatização fotoquímica foi utilizada para induzir ou amplificar a fluorescência de três substâncias utilizadas como princípios ativos em medicamentos: tetrabenazina (TBZ), amitriptilina (AMT) e vareniclina (VRN). Com o aumento de fluorescência após o tratamento com radiação UV, métodos espectrofluorimétricos foram desenvolvidos para determinar a concentração de TBZ, a AMT e a VRN em medicamentos e em matrizes biológicas. A avaliação da abordagem por cromatografia líquida de alta eficiência (HPLC) com detecção por fluorescência tambme foi avaliada para a AMT e VRN. Para a determinação de TBZ, a irradiação por 60 min em meio de NaOH (0,45 mol L-1) permitiu a sua quantificação espectrofluorimétrica com um limite de detecção (LD) de 1,4 x 10-8 mol L-1 e faixa linear até 1,0 x 10-5 mol L-1. O método espectrofluorimétrico foi aplicado para determinar TBZ no medicamento com recuperações entre 88 e 95%. A TBZ também foi determinada em saliva fortificada com o analito em concentração próxima ao do limite de quantificação (LQ) com recuperações maiores que 87%. Estudos usando espectrometria de massas com desorção de plasma estimulada por uma fonte de 252Cf foram realizados para identificar a estrutura do fotoderivado, indicando a fotólise da TBZ via reação de Norrish tipo I e II. Para a determinação de AMT, duas abordagens de derivatização fotoquímica permitiram determinar a substância por espectrofluorimetria e por HPLC. Para o método espectrofluorimétrico, a derivatização foi realizada expondo ao UV por 60 min uma solução de AMT, preparada em HCl 0,027 mol L-1. A faixa de resposta linear se estendeu até 1,0 x 10-5 mol L-1 de AMT com um LD de 4,8 x 10-8 mol L-1. Na abordagem cromatográfica, o processo de derivatização da AMT foi ajustado utilizando 30 min de UV em tampão fosfato pH 3. O método permitiu um LD de 6,9 x 10-9 mol L-1 com faixa linear até 2,5 x 10-6 mol L-1 de AMT. Os métodos desenvolvidos foram aplicados na determinação de AMT em medicamento e em material de referência farmacopéico com recuperações entre 94 e 105% para o método fluorimétrico e entre 99 e 111% para a abordagem cromatográfica. A aplicação na determinação da AMT em plasma humano fortificado na concentração de 1,0 x 10-6 mol L-1 forneceram resultados aceitáveis. Os fotoderivados fluorescentes foram separados e identificados por GC-MS, sendo proposto um mecanismo de fotólise da AMT. Para a determinação de VRN, a derivatização fotoquímica em meio básico permitiu a determinação da substância por espectrofluorimetria, sendo também avaliada uma abordagem por HPLC. A derivatização da VRN, realizada expondo o analito ao UV por 23 min em solução de NaOH 0,64 mol L-1, permitiu um LD de 1,5 x 10-8 mol L-1 e uma faixa linear até 1,0 x 10-6 mol L-1. As condições de fotoderivatização também foram adaptadas para a determinação cromatográfica do analito, irradiando-o por 10 min em meio de tampão borato (0,01 mol L-1 pH 10). A aplicação na determinação da VRN no medicamento com recuperações entre 93 e 102% foi alcançada. Para todos os métodos desenvolvidos foi realizada uma análise metrológica simplificada contemplando as fontes de incerteza mais relevantes para o processo de medição dos analitos: o preparo de soluções; a repetibilidade; a precisão intermediária e a curva analítica. As incertezas de medição para cada um dos métodos propostos foram estimadas em três concentrações distintas, no início, no meio e no fim da faixa linear. Os resultados obtidos foram entre 5,8 e 36% de incerteza do valor nominal das concentrações próximas ao LQ e entre 3,1 e 16% para as concentrações dentro na faixa linear dos métodos. Em todos os métodos desenvolvidos foram utilizados procedimentos de derivatização seguros, energeticamente eficientes e com redução de uso de solventes e substâncias tóxicas, em concordância com os princípios da química verde. / [en] Photochemical derivatization was employed to induce or amplify the fluorescence from three substances with pharmacological activities: tetrabenazine (TBZ); amitriptyline (AMT) and varenicline (VRN). The substantial fluorescence enhancement after UV irradiation allowed the development of methods based on spectrofluorimetry for TBZ, AMT and VRN. The approach was also evaluated in high performance liquid chromatography (HPLC) with fluorimetric detection for the determination of the concentration AMT and VRN in drugs or in biological matrices. For the determination of TBZ, 60 min of UV irradiation of the analyte prepared in NaOH (0.45 mol L-1) allowed its indirect quantification using spectrofluorimetry, with a limit of detection (LOD) of 1.4 x 10-8 mol L-1 and a linear response up to 1.0 x 10-5 mol L-1. Pre-concentration using solid phase extraction improved the LOD in one order of magnitude. The spectrofluorimetric method was applied for the determination of TBZ in a commercial drug, with recoveries between 88 and 95%. TBZ was also determined in analyte fortified saliva at a concentration near the limit of quantitation (LOQ) with recoveries greater than 87%. Studies using plasma desorption mass spectrometry with a 252Cf source, indicated that the photoderivatives of TBZ were obtained through a Norrish Type I and II TBZ photolysis. For the determination of AMT, two photochemical derivatization approaches allowed the determination of the substance by spectrofluorimetry. The approach using HPLC coupled to fluorescence detection was also tested. For the spectrofluorimetric method, the derivatization was achieved after 60 min of UV exposure of a solution of AMT prepared in HCl 0.027 mol L-1. The linear response of the method was up to 1.0 x 10-5 mol L-1 of AMT, with a LOD of 4.8 x 10-8 mol L-1. For the chromatographic method, the derivatization process was adjusted (30 min of UV irradiation in phosphate buffer, pH 3) in order to adapt the reaction for HPLC. The method allowed an LOD of 6.0 x10-9 mol L-1 with a linear range up to 2.5 x 10-6 mol L-1 of AMT. The determination of AMT in drugs and in a pharmacopeial reference material was performed, with recoveries between 94 and 105% for the fluorimetric method and between 99 and 111% using HPLC. The analysis of human plasma was also made using AMT (1.0 x 10-6 mol L-1) fortified samples. The fluorescent photoderivatives were separated and identified by GC-MS, which allowed the proposal of a photolysis mechanism of AMT. For the determination of VRN, the photochemical derivatization in basic medium allowed the determination of the substance by spectrofluorimetry. The derivatization of VRN, performed by exposing the analyte to the UV during 23 minutes in NaOH 0.64 mol L-1, allowed a LOD of 1.5 x10-8 mol L-1 and a linear range extending up to 1.0 x10-6 mol L-1. The derivatization condition were also adapted for the determination of the analyte using HPLC with fluorimetric detection, by irradiating VRN for 10 min in borate buffer (0.01 mol L-1 pH 10). Both methods were applied for the determination of VRN in a commercial drug, with recoveries between 93 and 102%. For all the developed methods, a simplified metrological evaluation was performed, considering the most relevant sources of uncertainty during the measurement process of the analytes studied in this thesis: solution preparation, intra and inter-day precision and the analytical curve. The uncertainty sources for each of the proposed methods were estimated in three different concentrations within the linear range. Measurement uncertainty estimations were between 5.8 and 36% of the nominal concentration in the concentrations near the LOQ and between 3.1 and 16% in the concentrations within the linear range of the methods. Safer, energetically efficient procedures with solvent reduction and without the use of toxic reagents were proposed, in agreement to green chemistry principles.

Page generated in 0.0838 seconds