1 |
[en] EXPERIMENTAL DESIGN AND METROLOGICAL EVALUATION OF LIPASE PRODUCTION BY YARROWIA LIPOLYTICA / [pt] PLANEJAMENTO EXPERIMENTAL E AVALIAÇÃO METROLÓGICA DA PRODUÇÃO DE LIPASES POR YARROWIA LIPOLYTICATATIANA DE MATTOS KERBER 09 October 2007 (has links)
[pt] Objetivo: Otimização da produção de lipases por células de
Yarrowia
lipolytica, através do planejamento experimental e
avaliação dos aspectos
metrológicos envolvidos no processo. Motivação: Embora
existam muitos
trabalhos na literatura que relatem a produção de lipases
por microrganismos,
poucos abordam a otimização do processo através do
planejamento experimental e
nenhum deles considera o rigor metrológico e a estimativa
da incerteza de
medição. Contextualização: As enzimas lipases serão objeto
de estudo por
apresentarem grande versatilidade de aplicações e por
serem produzidas por
muitos microrganismos. As leveduras, no entanto,
apresentam inúmeras vantagens
operacionais sobre os demais microrganismos e entre elas
foi selecionada uma
cultura de Yarrowia lipolytica, isolada no Brasil. A
produção de lipases depende
de muitas variáveis, como temperatura, pH, concentração da
fonte de carbono e
nitrogênio, inóculo, entre outras. Nos processos de
fermentação, onde há interação
entre estas variáveis e a influência de cada uma é
importante, é essencial
estabelecer um método que considere estas interações, e
otimize as condições
experimentais para obtenção de melhores resultados. A
confiabilidade
metrológica do processo é de fundamental importância uma
vez que diferenças
significativas nos resultados são evidenciadas,
principalmente em escala
industrial. Metodologia: Dez experimentos foram planejados
através do método
D-optimal nos quais foram variadas as concentrações da
fonte de carbono, da
fonte de nitrogênio e de inóculo. A estimativa da
incerteza de medição da
atividade lipásica foi feita com base nas recomendações do
Guia para Expressão
da Incerteza de Medição (GUM) e do Guia CG 4 publicado
pela EURACHEM.
Resultados: A maior atividade lipásica obtida foi de 4815
U/L (80,3 (mi)kat/L) com
incerteza expandida de 137 U/L (2,3 (mi)kat/L), nas
seguintes condições: 0,5% de
óleo de oliva (fonte de carbono), 0,7% de peptona (fonte
de nitrogênio) e
10 mg/mL de inóculo. Em termos de produtividade
volumétrica, tais condições
forneceram o valor de 69,28 U/L h. Conclusões: Com estes
resultados, foi possível concluir que a utilização do
planejamento D-optimal favoreceu a
produção em agitador de frascos, já que foi atingida uma
atividade lipásica
superior às alcançadas anteriormente por outros autores
sem otimização, em
frascos agitados (2700 U/L) ou em fermentador (4240 U/L).
Sugere-se a produção
de lipases por células de Yarrowia lipolytica, nas
condições citadas acima, com
vistas à obtenção de materiais de referência certificados,
desde que estudos
posteriores de purificação e estabilidade da lipase obtida
sejam feitos. / [en] Objective: Optimization of lipase production by Yarrowia
lipolytica cells
through experimental design and evaluation of metrological
aspects related to
process. Motivation: Although several published papers are
found describing
lipase production by microorganisms, few of them refer to
process optimization
through experimental design and none of them refer to
metrological evaluation
and the estimate of the uncertainty in measurement.
Context: Microbial lipases
are an important group of biotechnologically valuable
enzymes that present
widely diversified catalytic properties. The interest in
production of these versatile
enzymes increased significantly, due to the vast amplitude
of their industrial
applications. There are many microorganisms able to
produce lipases, but yeasts
present some operational advantages compared to other
microorganisms, and for
this reason a strain of Yarrowia lipolytica was used in
this work. A serie of
factors, individually or in association, can affect
production of such substances
leading to different levels of product concentration and
productivity. Empirical
studies have been traditionally used to determine the
effect of these factors on
process parameters. A possible approach is to vary one
factor while keeping the
other at a constant level, but this approach is time
consuming, does not include the
interaction effects among variables, and does not
necessarily lead to optimized
results. Nowadays, different strategies are employed to
optimize production
parameters. These strategies not only allow process
optimization but can also
establish the dependent and independent variables.
Methodology: Ten
experiments were planned with the D-optimal design in
which concentrations of
inoculum, carbon source and nitrogen source were changed.
The estimate of the
uncertainty in measurement of the lipase activity was
developed based on the
Guide to the Expression of Uncertainty in Measurement
(GUM) and on the Guide
CG 4 published by EURACHEM. Results: The highest lipolytic
activity obtained
was 4815 U/L (80,3 (mi)kat/L) with an expanded uncertainty
of 137 U/L
(2,3 (mi)kat/L), under the following conditions: 0.5% of
olive oil (carbon source),0.7% of peptone (nitrogen
source) and 10 mg/mL of inoculum. In terms of
volumetric productivity, these conditions provided 69.28
U/L h. Conclusions: It
is possible to conclude that the D-optimal design usage
enhanced lipase
production in shaken-flasks. Moreover the activity
obtained in this work was
higher than others previously reported with the same
microorganism, without
experimental design, in shaken-flasks (2700 U/L) or even
in bench-fermenter
(4240 U/L). The production of lipases by Yarrowia
lipolytica cells aiming the
classification as certified reference material can be
recommended after further
purification and stability studies.
|
2 |
[en] DEVELOPMENT OF A METHODOLOGY FOR CALIBRATING A TURBINE METER USED FOR MEASURING THE DISPLACED AIR VOLUME AND DETERMINATION OF ITS UNCERTAINTY OF MEASUREMENT / [pt] DESENVOLVIMENTO DE UMA METODOLOGIA PARA A CALIBRAÇÃO DE UMA TURBINA UTILIZADA PARA MEDIÇÃO DO VOLUME DESLOCADO DE AR E DETERMINAÇÃO DA SUA INCERTEZA DE MEDIÇÃOFLAVIOMAR SOARES DE SOUZA 11 December 2007 (has links)
[pt] Tendo em vista que as normas existentes não apresentam uma
metodologia
em relação à calibração de medidores tipo turbina e a
determinação da incerteza
de medição do volume deslocado de gases neste medidor,
este trabalho apresenta
uma metodologia para sistematizar os processos de
calibração. Para isso, foi
utilizado uma bancada de calibração com uma turbina. Com
os dados obtidos nos
testes foi possível processar os resultados obtidos para a
determinação das
incertezas de medição das variáveis envolvidas e avaliar o
desempenho do
medidor. Os dados experimentais de temperatura, pressão e
rotação da turbina
foram obtidos para ar com uma bancada já existente em um
laboratório de
calibração, tanto para a turbina master como para o
objeto, e os resultados obtidos
neste estudo estão sendo utilizados para sua acreditação
junto à Rede Brasileira
de Calibração (RBC). Os procedimentos de teste foram
desenvolvidos a partir de
normas existentes, especificação dos equipamentos e seu
desempenho, em
condições que permitissem a otimização da incerteza de
medição, calculada de
acordo com o ISO GUM. Assim, foi mostrado que a incerteza
de medição de
volume com a turbina de teste decresce quando o volume de
gás utilizado
aumenta, até um valor aproximadamente constante, definindo
sua condição de
calibração. Finalmente, uma metodologia foi desenvolvida
para determinar o fator
da turbina (K-factor) como uma função contínua do volume
indicado pela turbina de
teste ao longo da sua faixa de utilização, simplificando o
procedimento a ser
utilizado. / [en] Due to the fact that the existing standards don´t have a
methodology related to
the calibration of turbine meters and determination of the
measurement uncertainty
of the displaced gas volume in this meter, this research
presents a methodology for
standardizing the calibration processes. It was made
possible by the use of a
turbine based calibration rig. By processing the data
acquired during the tests, it
was possible to determine the measurement uncertainty of
the involved variables
and to evaluate the meter performance. Its temperature and
pressure, together with
the turbine speed, were measured in an existing rig of a
calibration laboratory, for
both master and test turbines, and the results are being
used to accredit the
laboratory to the Brazilian Calibration Network (RBC). The
test procedures were
developed from existing standards for similar testes,
equipment specification and
performance, and test conditions that allow the
optimization of the uncertainty of
measurement, in accordance to ISO GUM. This way, it was
shown that the
uncertainty of measurement of volume with the test turbine
decreases when the gas
volume increases, up to an approximately constant value,
which determines the
calibration condition. Finally, a methodology was
developed to determine the turbine
calibration factor (K-Factor) as a continuous function of
the indicated value by the
teste turbine along its operation range, simplifying the
procedure to be used.
|
3 |
[en] UNCERTAINTY OF MEASUREMENT IN ARTIFICIAL NEURAL NETWORKS APPLIED ON THE PREVENTATIVE MAINTENANCE OF TRANSFORMERS / [pt] INCERTEZA DE MEDIÇÃO EM REDES NEURAIS ARTIFICIAIS APLICADAS À MANUTENÇÃO PREDITIVA DE TRANSFORMADORESCHRISTIANE SAMPAIO DE ALMEIDA GUSMAN 30 March 2012 (has links)
[pt] Diversas pesquisas sobre monitoramento e diagnóstico de equipamentos do sistema elétrico foram iniciadas com o objetivo de elevar a garantia e confiabilidade no sistema. Autores, não somente no Brasil, desenvolveram pesquisas sobre o tema, dentre eles (Bengtson, 1996; Kovacevic & Dominelli, 2003; Freitas, 2000). O objetivo é garantir a confiabilidade dos equipamentos instalados e incrementar o desempenho aumentando a vida útil dos mesmos. Nesse contexto (Freitas, 2000; Cavaleiro, 2003; dentre outros) discorrem sobre o tema. As redes neurais artificiais são utilizadas como uma das possíveis ferramentas disponíveis para análise, diagnóstico e monitoramento de equipamentos. A inovação deste trabalho está em apresentar uma nova metodologia desenvolvida para analisar a propagação das incertezas de medição das variáveis de entrada em redes neurais artificiais aplicadas à Manutenção Preditiva de Transformadores. Com base nos conceitos da metrologia foram analisados não somente os dados de entrada como também a incerteza de medição associadas aos mesmos. O método desenvolvido permite que se estime a incerteza de medição das variáveis de saída, contribuindo para a avaliação da confiabilidade de modelagens baseadas em redes neurais. Também foi realizado um estudo de caso, no qual se avaliou a propagação das incertezas de medição em sete redes neurais destinadas a estimar a concentração dos gases (saídas das redes) dissolvidos no óleo de transformadores de potência, com base nas características físico-químicas do óleo (variáveis de entrada). A metodologia utilizada baseou-se na introdução de perturbações na
entrada das redes analisadas e na consequente análise de como estas perturbações afetam a saída das redes, permitindo-se assim calcular os coeficientes de sensibilidade de cada entrada. Em seguida, combinando-se as incertezas de medição das variáveis de entrada (disponíveis nos certificados de calibração dos instrumentos utilizados nas respectivas medições), por meio dos coeficientes de sensibilidade, é possível estimar a incerteza de medição das variáveis de saída. / [en] Research about monitoring and diagnostics of electrical system equipment was initiated with the objective of upgrading the guarantee and trust of a system. Authors, not only in Brazil, have developed research about the subject, among them (Bengtson, 1996; Kovacevic & Dominelli, 2003; Freitas, 2000). The objective is to guarantee the confidence in the equipment installed and enhance the performance and increase the durability of the equipment. Within this context (Freitas, 2000; Cavaleiro, 2003; among others) talk about this subject. The artificial Neural Networks are used as one of the possible available tools for analysis, diagnostics and monitoring of equipment. The innovation of this paper is to present a new methodology developed to analyze the propagation of uncertainty measurement variables of input in artificial neural networks applied to predictive maintenance of transformers. Based on the concepts of metrology, not only the input data was analyzed but also the uncertainty measurements that were associated with the equipment. The method that was developed allows us to estimate the measurement of uncertainty of output variables, contributing to the evaluation of confidence of models based on neural networks. There was also a case study, in which the propagation of uncertainties of measurement were evaluated within seven designated neural networks to estimate the concentration of gases (output of the networks) dissolved in potency transformer oil, based on the physical-chemical characteristics of
the oil (input variables). The methodology that was utilized was based on the introduction of perturbation at the input of the networks that were analyzed and the consequent analysis of how these perturbation affect the output of the networks, this way allowing the calculation of the coefficients of sensibility of each entry. Then we match the input variables of the uncertainty measurements (available on the calibration certificates of the instruments utilized on the respective measurements), through the coefficients of sensibility, it is possible to estimate the output variables of the uncertainty measurements.
|
4 |
[en] CELLULOSE SUBSTRATE ROOM-TEMPERATURE PHOSPHORIMETRY FOR THE DETERMINATION OF 2 METHYL INDOL E 7 METHYL INDOL: METHOD DEVELOPMENT, VALIDATION AND CRITICAL EVALUATION OF THE APPLICABILITY OF THE TECHNIQUE / [pt] FOSFORIMETRIA EM TEMPERATURA AMBIENTE EM SUBSTRATO DE CELULOSE PARA A DETERMINAÇÃO DE 2 METIL INDOL E 7 METIL INDOL: DESENVOLVIMENTO DE MÉTODO, VALIDAÇÃO E AVALIAÇÃO CRÍTICA DA APLICABILIDADE DA TÉCNICASELMA CUNHA MELLO 05 November 2008 (has links)
[pt] Neste trabalho, a fosforimetria em temperatura ambiente
em
substrato de celulose foi avaliada como técnica analítica
para a determinação de dois derivados do indol (2 metil
indol e 7 metil indol). As características fosforescentes
dos dois analitos foram estudadas de modo univariado em
função de diversos parâmetros experimentais como a taxa
de
decaimento do sinal fosforescente; tipo e quantidade de
sal
de átomo pesado indutor de fosforescência; quantidade
de surfactante modificador de superfície da celulose e
influência da concentração hidrogeniônica da solução de
analito. Uma vez definidos os fatores relevantes,
planejamentos fatoriais do tipo composto central foram
realizados com o intuito de obter superfícies de resposta
que apontassem possíveis interações entre os fatores e
ajudassem na escolha da melhor condição experimental. As
melhores condições para o 2 metil indol foram obtidas com
soluções carreadoras de etanol/água no seu pH original e
em
substratos contendo TlNO3/SDS ou KI. Condições similares
foram obtidas para o 7 metil indol. Para cada uma das
condições selecionadas, foram realizados estudos
para avaliação dos parâmetros de desempenho que
incluíram:
seletividade, linearidade da faixa de trabalho, limite de
detecção, limite de quantificação, exatidão, precisão,
robustez e cálculo de incerteza de medição do sinal
fosforescente em substrato sólido. Em todos os casos
estudados, a resposta analítica apresentou comportamento
linear em função da massa depositada no substrato [R(2) >
0,99]. Os limites de detecção (média dos valores de
branco +
3sb) e de quantificação (média dos valores de branco +
10sb) ficaram na ordem de 10(-5) de mol L(-1) (na ordem
de
dezenas de ng em termos absolutos). A repetitividade do
método apresentou valores entre 15 e 23 % sendo a
principal
componente da incerteza de medição de sinal
fosforescente.
Este valor foi calculado seguindo o procedimento indicado
pelo ISO GUM, ficando entre 22 a 35% (incerteza
combinada)
dependendo da condição experimental e do analito
usado no processo de cálculo. A seletividade foi avaliada
por meio da comparação das características espectrais de
quatro indóis (indol, 2 metil indol, 3 metil indol e 7
metil indol) e entre compostos nitrogenados de diferentes
famílias (quinolina, 7,8 benzoquinolina e acridina). Os
resultados mostraram que não é possível discriminar os
compostos indólicos. Entretanto é possível obter
seletividade para compostos nitrogenados de diferentes
famílias. / [en] In this work, room-temperature phosphorimetry using
cellulose substrates was evaluated as analytical technique
for the determination of two indol derivatives (2 methyl
indol and 7 methyl indol). The phosphorescence from both
analytes were studied in a univaried way in function of
several experimental parameters such as the phosphorescence
decay rate; type and quantity of phosphorescence inducer
(heavy atom salt); amount of surfactant used as
cellulose surface modifier and the influence of the
hidrogenionic concentration of the analyte carrier
solution. Once defined the relevant factors, central
composite designs were performed in order to obtain
response surfaces that pointed out possible interactions
among factors and lead to the best experimental conditions.
For 2 methyl indol, the best conditions were achieved by
using ethanol/water analyte carrier solution at its
original pH, and substrates containing TlNO3/SDS or
KI. Simillar conditions were found for 7 methyl indol. For
each of the selected conditions, studies were performed
aiming to find the analytical figures of merit
which included: selectivity, linearity of the working
range, limit of detection, limit of quantification,
accuracy, precision, robustness and the uncertainty of the
phosphorescence measurement from the solid substrate. In
all cases, the linear response presented a linear behavior
in function of the mass of the analytes placed on the
substrate [R(2) > 0,99]. Limits of detection (blank signals
average + 3sb) and limits of quantification (blank signals
average + 10sb) were in the mol L(-1) range (absolut values
of tenths of ng). The repeatability of the method presented
values between 15 and 23%, being the main components of the
phosphorescence measurement, which were calculated based on
the procedure indicated in the ISO GUM. The uncertainty
value was between 22 and 35% (combined uncertainty)
epending on the experimental condition and on the
analyte used in the calculation process. The selectivity
towards other indols (indol and 7 methyl indol) and other
classes of nitrogenated polycyclic aromatic compounds was
evaluated by comparing phosphorescence characteristics from
these substances. While no discrimination was possible for
the indols, selectivity in the determination of 2 methyl
indol and 7 methyl indol in the presence of acridine, 7,8
benzoquinoline and quinoline) was found.
|
5 |
[en] DEVELOPMENT OF ANALYTICAL METHODS BASED ON LUMINESCENCE AND ELECTROPHORESIS FOR THE DETERMINATION OF ALKALOIDS (BETA-CARBOLINES, CAMPTOTHECIN AND DERIVATIVES) OF PHARMACOLOGICAL INTEREST / [pt] DESENVOLVIMENTO DE MÉTODOS ANALÍTICOS ESPECTROLUMINESCENTES E ELETROFORÉTICOS PARA A DETERMINAÇÃO DE ALCALOIDES (BETA-CARBOLINAS, CAMPTOTECINA E DERIVADOS) DE INTERESSE FARMACOLÓGICOFLAVIA FERREIRA DE CARVALHO MARQUES 14 October 2009 (has links)
[pt] Métodos analíticos foram desenvolvidos para a determinação seletiva de
alcalóides de interesse farmacológico. Com o objetivo de permitir a determinação
seletiva de camptotecina (CPT) em formulações farmacêuticas de irinotecana
(CPT-11) ou de topotecana (TPT), dois métodos espectrofluorimétricos e um
eletroforético, com detecção por fotometria de absorção, foram propostos. Os
métodos espectrofluorimétricos permitiram a determinação seletiva de CPT
usando um ajuste de alcalinidade do meio associado ao uso de varredura
sincronizada ou de derivada de 2ª ordem. Alternativamente, o procedimento de
derivação fotoquímica (com otimização com planejamento composto central)
eliminou completamente as interferências no sinal do CPT. Nas condições
otimizadas, a espectrofluorimetria permitiu a determinação de CPT em misturas
contendo até 50 vezes mais TPT ou contendo até 10 vezes mais CPT-11. A
resposta analítica indicou faixas lineares de trabalho e homoscedasticidade. O
limite de detecção (LD) foi da ordem de 10(-10) mol L(-1) para o método baseado na
derivação fotoquímica e uma ordem de grandeza a menos para os métodos sem
derivatização fotoquímica. Testes foram feitos em medicamentos a base de TPT
e de CPT-11 e as recuperações ficaram em torno de 100%. Esses resultados
foram comparáveis aos obtidos com método de referência (HPLC). O estudo de
incerteza de medição por fluorimetria indicou que a maior contribuição do
processo era a preparação de solução por avolumação. A contribuição dessa
fonte foi minimizada pela preparação de solução por meio de ajuste de massa,
causando um grande impacto na redução da incerteza expandida. O método
baseado na eletroforese eletrocinética capilar micelar (MEKC) permitiu a
quantificação simultânea de TPT, CPT e CPT-11. Para conseguir o ajuste final
das melhores condições, foi feito um estudo univariado seguido de um
planejamento composto central. Para se melhorar a sensibilidade da detecção
em até 76 vezes, foi utilizado um processo de pré-concentração no capilar por
modo de empilhamento e uma cela de caminho óptico alongado. A escolha do
tampão borato (pH 8,5) contendo SDS e acetonitrila permitiu condições robustas 7
de sinal de tempo de migração. A resposta analítica mostrou faixa linear e
homoscedatidade, além de repetitividade em torno de 3,5%. O LD foi da ordem
de 10(-7) mol L(-1) (TPT) e 10(-8) mol L(-1) (CPT-11 e CPT). Testes de recuperação em
amostras de saliva fortificadas foram feitos e comparados com os obtidos por um
método de referência (HPLC) de forma a mostrar a exatidão adequada para o
método proposto. Para a determinação seletiva de B-carbolinas, a fosforimetria
em substrato sólido (SSRTP) foi utilizada. O ajuste do átomo pesado seletivo e a
aplicação de técnica de varredura sincronizada e de 2ª derivada aumentaram o
grau de seletividade, pois induziu fosforescência dos analitos de interesse na
amostra e melhorou a resolução espectral em relação aos interferentes. O ajuste
da quantidade de HgCl2 (0,81 mg) permitiu a determinação seletiva de harmol na
presença de quantidades até 10 vezes maiores de harmine, harmane,
norharmane e harmaline. O método SSRTP seletivo proposto para determinação
de harmol foi comparado com o resultado obtido por um método de referência
adaptado baseado em MEKC, o qual também mostrou sua capacidade para a
determinação seletiva de harmol na presença dos interferentes. LD absoluto na
ordem de ng e comportamento linear da resposta analítica foram obtidos. No
caso do método analítico desenvolvido para a determinação de harmane na
presença de harmine em chás, estudos de otimização mostraram o AgNO3 como
sal de átomo pesado no substrato, solução de amostra em pH 11 e medições
feitas em 322 nm do espectro de 2ª derivada da varredura sincronizada
((delta)(lambda) = 109 nm). Testes de interferência mostraram que a matriz do chá não tem
influência no sinal do harmane e que nas / [en] Analytical methods were developed for the selective determination of
alkaloids of pharmacological interest. Aiming the selective determination of
camptothecin (CPT) in irinotecan (CPT-11) or topotecan (TPT) based
pharmaceutical formulations, two spectrofluorimetric methods and one
electrophoretic method with absorciometic detection were proposed. The
spectrofluorimetric method allowed the determination of CPT using the
adjustment of the alkalinity of the sample solution associated with the use of
synchronous scanning or 2nd order spectral derivation. Alternativelly, the
photochemical derivatization (optimized by central composite design) completely
eliminated interferences on the CPT signal. The optimized conditions allowed the
spectrofluorimetric determination of CPT in mixtures containing up to 50 times
more TPT or up to 10 times more CPT-11. The analytical response presented
linear working ranges and homocedasticity. The limit of detection (LD) was in the
order of 10(-10) mol L(-1) for the method based on photochemical derivatization and
one order of magnitude higher for the methods without photochemical
derivatization. Tests were made using TPT and CPT-11 based comercial drugs
and recoveries were around 100%. Such results were comparable to those
obtained with the reference method (HPLC). A study of fluorimetric measurement
uncertainty indicated that the greatest contribution in the process was the
preparation of solution by volume. The contribution from this source was
minimized by the preparation of solutions by weight measurement which caused
a major impact in reducing the expanded uncertainty. The method based on
micellar electrokinetic capillary electrophoresis (MEKC) allowed the simultaneous
quantification of TPT, CPT and CPT-11. To achieve final adjustment of
conditions, an univariated study was made followed by a central composite
design. To improve the sensitivity of detection up to 76 times, a pre-concentration
in the capillary by the normal stacking mode was used along with an extended
optical path cell. The choice of borate buffer (pH 8.5) containing SDS and
acetonitrile implicated in robust conditions of signal and migration times. The
response showed analytical linear working range and homocedasticity, and
9 repeatability of around 3.5%. The LD was in the order of 10(-7) mol L(-1) (TPT) and
10(-8) mol L(-1) (CPT-11 and CPT). Recovery tests using spiked saliva samples were
made and compared with those obtained by a reference method (HPLC) to show
the appropriated accuracy for the proposed method. For the selective
determination of B-carbolines, solid surface room temperature phosphorimetry
(SSRTP) was used. The adjustment of the selective heavy atom and the
application of synchronized scanning technique and 2nd order spectral derivation,
increased the degree of selectivity, because induced phosphorescence of the
analytes of interest in the sample and improved spectral resolution. The
adjustment of the amount of HgCl2 (0.81 mg) allowed the selective determination
of harmol in the presence of up to 10 times higher amounts of harmine, harman,
harmaline and norharman. The method proposed for selective SSRTP
determination of harmol was compared with the results obtained by an adapted
method based on MEKC, which also showed its ability to determine harmol in the
presence of interferences. The absolute limit of detection in the ng order and
linear behavior of the analytical response was obtained. For the analytical
method developed for the determination of harman in the presence of harmine in
teas, optimization studies indicated the following conditions: AgNO3 as the heavy
atom salt deposited on the substrate, sample solution at pH 11 and
measurements made at 322 nm of the 2nd order derivated synchronous scanning
spectrum ((delta)(lambda) = 109 nm). Tests showed that, in optimized conditions, the tea
matrix had no influence on the harman signal and and that harman could be
determined in samples containing harmine in concentrations up to two times
higher. The
|
6 |
[en] STUDY OF THE METROLOGICAL RELIABILITY OF SPHYGMOMANOMETERS / [pt] ESTUDO DA CONFIABILIDADE METROLÓGICA DE ESFIGMOMANÔMETROSSERGIO HENRIQUE SILVA JUNIOR 08 October 2008 (has links)
[pt] Observa-se um crescente interesse na determinação da
incerteza de medição para a avaliação de conformidade e
garantia da qualidade, principalmente nos setores de meio-
ambiente, segurança, saúde e indústria, nos quais o
resultado da medição é considerado crítico por lidar
diretamente com seres humanos. Na medição da pressão
arterial, conforme estudos realizados em países como a
Austrália, Inglaterra, Turquia e Brasil, observa-se uma
grande preocupação com a confiabilidade dos resultados
obtidos por esfigmomanômetros mecânicos não invasivos.
Nestes estudos, erros de até 4,4 kPa (33 mmHg) foram
encontrados nos instrumentos avaliados, contra o valor de
erro máximo de 0,53 kPa (4 mmHg) definido
na OIML R 16-1:2002. Atualmente, a avaliação da
confiabilidade dos esfigmomanômetros
mecânicos é obtida considerando apenas o erro de medição,
sem considerar a incerteza de medição. Com a motivação de
contribuir para a garantia da confiabilidade metrológica
dos esfigmomanômetros mecânicos não invasivos,
usados mundialmente em hospitais e residências, o presente
trabalho tem por objetivo associar a incerteza de medição
na avaliação da confiabilidade metrológica
destes instrumentos. Para a realização das medições foi
montado um aparato envolvendo instrumentos de monitoração
ambiental conforme recomendações internacionais
(OIML R-16-1:2002) e nacionais (ABNT NBR-14105:1998 e
NIEDIMEL- 006). Os dados do presente trabalho foram obtidos
por meio de medições diretas em esfigmomanômetros novos e
usados utilizando um padrão de pressão. Foram avaliados: o
erro de medição, a histerese, o erro fiducial e a incerteza
de medição. Os resultados obtidos com o presente trabalho
mostram que, em função da incerteza de medição, o erro
máximo permissível de 0,53 kPa (4 mmHg) pode
não fornecer a confiabilidade adequada. Se for considerado
apenas o erro de medição do manômetro conforme a OIML R 16-
1:2002, 60 % dos esfigmomanômetros avaliados foram
aprovados. Se for considerado o erro e a incerteza de
medição do manômetro, conforme proposto, apenas 12 % dos
esfigmomanômetros foram aprovados. Com base nos resultados
obtidos no presente trabalho, propõe-se reduzir o erro
máximo admissível para estes instrumentos, incorporando a
incerteza de medição, sem a necessidade de realizar na
prática o seu cálculo. Com base nos resultados do presente
trabalho recomenda-se uma revisão na faixa de
erro máximo permissível na avaliação da OIML, em conjunto
com a proposta de uma nova especificação do manômetro usado
nos esfigmomanômetros, com redução do erro intrínseco e
melhora de sua resolução. / [en] It is observed an increasing interest on the estimation of
measurement uncertainty
to deciding on conformity and quality assurance, mainly in
the fields of
environment, safety, health and industry, in which the
measurement results are
critical once they directly deal with human beings.
According to studies performed
in Australia, England, Turkey and Brazil, a great concern
is observed with
the reliability of the results obtained for blood pressure
measurements by noninvasive
mechanical sphygmomanometers. In these studies, errors of
up to 4,4 kPa
(33 mmHg) were obtained in the evaluated instruments,
against the value of maximum
error of 0,53 kPa (4 mmHg) required by OIML R 16-1:2002.
Nowadays,
the evaluation of the reliability of these measurement
instruments for medical diagnosis
is obtained considering only the measurement error
(according to OIML R
16-1:2002), without taking into account the measurement
uncertainty. Motivated
to contribute for the metrological reliability of non-
invasive mechanical sphygmomanometers,
globally used in hospitals and residences, the present work
aims
at developing a model to associate the measurement
uncertainty on the metrological
reliability evaluation of these instruments. In order to
perform the measurements
with the sphygmomanometers, a set-up were prepared with
environmental
monitoring according to international recommendation (OIML
R-16:2002) and
national standards (ABNT NBR-14105:1998 and NIE-DMEL-006).
The data of
the present work were obtained by means of direct
measurements in new and in
use sphygmomanometers, utilizing a pressure pattern.
Calculation of the following
parameters was performed: measurement error, hysteresis,
fiducial error and
measurement uncertainty. The obtained results show that, as
a function of the
measurement uncertainty, the maximum permissible error of
0.53 kPa (4 mmHg)
can be overcome. Considering the manometer measurement
error, according to OIML R 16-1:2002, 60 % of the non-
invasive mechanical sphygmomanometers
evaluated were approved. When considering not only the
measurement error, but
also measurement uncertainty of the manometer, only 12% of
the non-invasive
mechanical sphygmomanometers were approved. Based on the
present results, a
reduction of the maximum permissible error for these
instruments, incorporating
the measurement uncertainty, without the need to calculate
it in the verification
procedure, is proposed. This work recommends not only a
review of OIML maximum
permissible error for sphygmomanometers, but also proposes
a new configuration
of the instrument, with reduction of intrinsic error and
improvement of
resolution.
|
7 |
[en] INTERFEROMETRIC PRIMARY SYSTEM FOR LENGTH MEASUREMENTS AND APPLICATIONS IN NANOMETROLOGY / [pt] SISTEMA INTERFEROMÉTRICO PRIMÁRIO PARA MEDIDAS DE COMPRIMENTO E APLICAÇÕES EM NANOMETROLOGIA02 January 2015 (has links)
[pt] Neste trabalho são apresentados os resultados referentes ao desenvolvimento de um sistema interferométrico primário, o interferômetro Linnik, para medidas de comprimento de amostras na escala micrométrica e nanométrica. O sistema experimental foi caracterizado e otimizado para prover rastreabilidade a degraus de altura, usados como referência na escala de comprimento. As principais fontes de incerteza foram avaliadas, sendo a planicidade do artefato o parâmetro com o maior valor de contribuição para a incerteza final. A estabilidade do sistema de referência pode ser mostrada através da alta reprodutibilidade apresentada ao longo de algumas semanas de medição. Este também serviu como base para prover a rastreabilidade no SI, para instrumentos ópticos tais como OCT, AFM e microscópios confocais, sendo os dois últimos usados na área de nanotecnologia. Estes instrumentos foram calibrados usando como padrão de transferência os degraus de altura, previamente avaliados no interferômetro Linnik. Com isto, foi estabelecida a rastreabilidade na escala de comprimento para alguns institutos no país. / [en] In this work are presented the results related to the development of a primary interferometric system, the Linnik interferometer for length measurements of samples in the micrometer and nanometer scales. The experimental system has been characterized and optimized to provide traceability to step height, used as the reference standards in length scale. The main sources of uncertainty were evaluated, and the flatness of the artifact was the parameter with the highest contribution to the final uncertainty. The stability of the reference system can be demonstrated through the reproducibility that was evaluated over several weeks. This system also served as the basis to provide traceability to the SI for optical instruments such as OCT and confocal microscopes AFM, the latter two being used in the field of nanotechnology. These instruments were calibrated using step heights, as transfer standards, that were previously evaluated in Linnik interferometer. Therefore, it was established the traceability in length scale for some institutes in the country.
|
8 |
[en] CONTRIBUTIONS FOR THE STRENGTHENING OF THE BRAZILIAN NATIONAL LABORATORY OF TIME AND FREQUENCY / [pt] CONTRIBUIÇÕES PARA O FORTALECIMENTO DO LABORATÓRIO NACIONAL BRASILEIRO DE METROLOGIA DE TEMPO E FREQÜÊNCIAJOSE LUIZ MACHADO KRONENBERG 13 December 2007 (has links)
[pt] Objetivos: três são os objetivos centrais da presente
pesquisa de mestrado em
metrologia: (i) no âmbito da missão institucional da
Divisão Serviço da Hora (DSHO)
do Observatório Nacional (ON), desenvolver um diagnóstico
da melhor capacidade de
medição e do sistema da qualidade do Laboratório Primário
de Tempo e Freqüência
(LPTF); (ii) à luz das práticas internacionais, calcular e
expressar as incertezas de
medição associadas à realização e disseminação das
unidades de tempo e freqüência em
âmbito nacional; (iii) em atendimento às exigências do
Acordo de Reconhecimento
Mútuo celebrado pelo Brasil no âmbito da Convenção do
Metro, preparar e
disponibilizar a declaração da melhor capacidade de
medição (CMC) do LPTF, na base
de dados do Bureau International des Poids et Mesures
(BIPM).
Motivação: a presente pesquisa de mestrado foi motivada
pela necessidade de
se: (i) formalizar a melhor capacidade de medição na base
internacional de dados Key
Comparison Data Base (KCDB) do Bureau International des
Poids et Mesures (BIPM);
(ii) adequar a nova estrutura do DSHO/ON às instalações da
recém-construída infraestrutura
laboratorial; (iii) estabelecer a rastreabilidade nacional
em TF para atender à
nova formulação introduzida pelo BIPM (método AV); (iv)
implementar o Plano de
Ações para melhoria do Sistema da Qualidade da DSHO, pré-
condição ao
reconhecimento nacional e internacional da metrologia
brasileira em TF.
Contextualização: em Metrologia, as comparações
interlaboratoriais
constituem-se em prática e exigências para se garantir
padronização e a confiança mútua
nos processos de desenvolvimento e aprimoramento de
métodos e processos de
medição. A medição e difusão da grandeza tempo (data-hora)
necessitam rastreabilidade
permanente e contínua ao padrão mundial, impondo aos
laboratórios que participam da
cadeia de rastreabilidade uma responsabilidade e
dificuldade operacional para
manutenção ininterrupta deste serviço. A melhoria e
manutenção do Sistema da
Qualidade, a caracterização das incertezas de medição e a
divulgação desses dados junto aos foros internacionais por
meio do BIPM constituem responsabilidades da missão
institucional do Laboratório Primário de Tempo e
Freqüência.
Metodologia: o trabalho desenvolveu-se em conformidade aos
seguintes
preceitos metodológicos: (i) diagnóstico e caracterização
dos padrões (primários e
secundários), equipamentos e sistemas de medição
disponíveis; (ii) identificação das
variáveis críticas dos sistemas de medição, com vistas à
determinação das incertezas a
elas associadas, tendo como referência o Guide to the
Expression of Uncertainty in
Measurement (GUM) e a Variância de Allan (avaliação da
estabilidade de osciladores);
(iii) caracterização da estrutura da rastreabilidade
brasileira em tempo e freqüência e
definição do seu status junto ao BIPM (formalizado
mensalmente pela sua Circular-T);
(iv) caracterização da melhor capacidade de medição do
LPTF, para torná-la disponível
na base de dados KCDB do BIPM.
Resultados: à luz das práticas internacionais, os
seguintes resultados foram
consolidados: (i) expressão das incertezas de medição
associadas à realização e
disseminação das unidades de Tempo e Freqüência do LPTF do
Brasil; (ii) expressão e
padronização da melhor capacidade de medição em TF do LPTF
para inclusão na base
de dados internacional KCDB do BIPM; (iii) caracterização
e equacionamento de
questões críticas dos processos de calibração que afetam a
melhor capacidade de
medição e do Sistema da Qualidade da DSHO.
Conclusões: com base numa avaliação crítica do sistema
instalado, o presente
trabalho contribuiu para a consolidação de um sistema de
metrologia primária de TF
mais robusto no Brasil, viabilizando a implementação
operacional de novos padrões e
equipamentos, rotinas de monitorament / [en] Objectives: the three main objectives of the present
research project are as
follows: (i) to develop a diagnosis of the best
calibration and measuring capability and
the quality system of the Brazilian National Time and
Frequency Primary Laboratory (
LPTF ) of the Time Service Division ( DSHO ) of the
National Observatory (ON) ; (ii)
to calculate and express, in accordance with international
practices, the measuring
uncertainties associated with the achievement and
dissemination of the time and
frequency units within the country and (iii) to prepare
and make available the
declaration of the best calibration and measurement
capability (CMC) of the LPTF
according to the database of the Bureau International des
Poids et Measures (BIPM) as
required by the Mutual Recognition Agreement (signed by
Brazil within the scope of
the Convention of the Metre).
Motivation: several factors motivated this master´s degree
research project: (i)
the necessity of making available the best calibration and
measurement capability
according with the international Key Comparison Data Base
(KCDB ) of the Bureau
International de Poids et Measures (BIPM); (ii) the need
to adapt the new structure of
the Time Service Division (DSHO) of the National
Observatory (ON) to the recently
built laboratory infrastructure; (iii) the necessity of
establishing a national traceability of
TF according to the new format introduced by the BIPM (AV
method) and (iv) the
urgent need to implement the Action Plan to improve the
Quality System of the
DSHO, a pre-established condition to both, national and
international recognition.
Context: In metrology, interlaboratory comparisons are
common practice. This
is the recommended procedure to guarantee standardization
and mutual recognition in
the development and improvement of methods of measurement.
Measurement and
dissemination of time (date-hour), in particular, requires
continuous and permanent
traceability to international standards as they impose to
time and frequency laboratories
an uninterrupted provision of this service. The
improvement and surveillance of the
Quality System, the characterization of the measuring
uncertainties and dissemination of time and frequency data
to the relevant international fora to meet BIPM
requirements
constitute responsibilities of the institutional mission
of any Primary Time and
Frequency Laboratory.
Methodology: the present work was developed in accordance
with the
following methodological principles: (i) diagnosis and
characterization of the standards
(primary and secondary), equipment and measuring systems
available at the LPTF; (ii)
identification of the critical variables of the measuring
systems to determine the
uncertainties associated with the measuring of time and
frequency, having the Guide to
the Expression of Uncertainty in Measurement (GUM) and the
Allan Variance
(oscillators stability evaluation) as reference; (iii)
characterization of the Brazilian time
and frequency traceability structure and its formalization
in accordance with the
monthly formalized BIPM Circular-T; (iv) characterization
of the CMC of the LPTF to
make it available at the KCDB of the BIPM.
Results: according to international practices, the
following results were
consolidated: (i) expression of the measuring
uncertainties associated to the realization
and dissemination of time and frequency; (ii) expression
and standardization of the best
calibration and measuring capability in time and frequency
of the LPTF to be included
in the BIPM Key Comparison Data Base; (iii)
characterization and understanding of
critical issues inherent to calibration processes which
directly affect the best
measurement capability and the Quality System of the DSHO.
Conclusion: based on a critical evaluation of the
metrological system in place,
the present work has contributed to the consolidation of a
more robust primary system
of time and frequency in Brazil. Such system allows for
the
|
9 |
[en] FUZZY PROBABILITY ESTIMATION FROM IMPRECISE DATA / [pt] ESTIMAÇÃO DE PROBABILIDADE FUZZY A PARTIR DE DADOS IMPRECISOSALEXANDRE ROBERTO RENTERIA 20 April 2007 (has links)
[pt] Existem três tipos de incerteza: a de natureza aleatória,
a gerada pelo conhecimento
incompleto e a que ocorre em função do conhecimento vago
ou impreciso. Há casos em que
dois tipos de incerteza estão presentes, em especial nos
experimentos aleatórios a partir de
dados imprecisos. Para modelar a aleatoriedade quando a
distribuição de probabilidade que
rege o experimento não é conhecida, deve-se utilizar um
método de estimação nãoparamétrico,
tal como a janela de Parzen. Já a incerteza de medição,
presente em qualquer
medida de uma grandeza física, dá origem a dados
imprecisos, tradicionalmente modelados
por conceitos probabilísticos. Entretanto, como a
probabilidade se aplica à análise de
eventos aleatórios, mas não captura a imprecisão no
evento, esta incerteza pode ser melhor
representada por um número fuzzy segundo a transformação
probabilidade-possibilidade
superior. Neste trabalho é proposto um método de estimação
não-paramétrico baseado em
janela de Parzen para estimação da probabilidade fuzzy a
partir de dados imprecisos. / [en] There are three kinds of uncertainty: one due to
randomness, another due to
incomplete knowledge and a third one due to vague or
imprecise knowledge. Sometimes
two kinds of uncertainty occur at the same time,
especially in random experiments based on
imprecise data. To model randomness when the probability
distribution related to an
experiment is unknown, a non-parametric estimation method
must be used, such as the
Parzen window. Uncertainty in measurement originates
imprecise data, traditionally
modelled through probability concepts. However, as
probability applies to random events
but does not capture their imprecision, this sort of
uncertainty is better represented by a
fuzzy number, through the superior probability-possibility
transformation. This thesis
proposes a non-parametric estimation method based on
Parzen window to estimate fuzzy
probability from imprecise data.
|
10 |
[en] USE OF ULTRASONIC FLOW METERS FOR TRANSFER CUSTODY OF NATURAL GAS / [pt] UTILIZAÇÃO DE MEDIDORES ULTRASSÔNICOS PARA MEDIÇÃO FISCAL DE VAZÃO DE GÁS NATURALCLAUDINEI MARCHETI JUNIOR 09 February 2018 (has links)
[pt] A medição de gás natural pelo princípio do ultrassom se mostra competitiva, sob diversos aspectos, quando comparada com medidores deprimogênios, em especial a placa de orifício. O presente trabalho apresenta uma avaliação técnica da utilização de medidores ultrassônicos de múltiplos feixes em sistemas fiscais e para transferência de custódia. Uma avaliação de conformidade em relação às principais normas internacionais relativas à medição de vazão de gás natural pelo princípio do ultrassom é realizada através de dados coletados, para um mesmo medidor, durante sua calibração em laboratório e durante sua operação no campo. Apresenta também uma análise das ferramentas de diagnósticos disponíveis pelo medidor, comparando os resultados obtidos em laboratório e no campo. Foi proposta uma metodologia para a determinação das estimativas de incerteza da medição da vazão instantânea e do volume de gás em determinado intervalo de tempo. As avaliações de conformidade com as normas e as análises das ferramentas de diagnósticos disponíveis mostram que a utilização de medidores ultrassônicos na medição fiscal de gás natural é tecnicamente viável; além disto, considerando um intervalo de tempo conveniente para a totalização dos volumes medidos, a incerteza de medição pode ser bastante reduzida. / [en] The measurement of natural gas by the ultrasonic principle is shown to be competitive in several aspects when compared with orifice plate meters. This paper presents a technical evaluation of the use of multipath ultrasonic meters for custody transfer. The analysis of the meter performance matching with the requirements of principal international standards for measuring of natural gas flowrate by the ultrasonic principle is made using data collected for the same meter during the calibration in laboratory and during operation in the field. It also presents an analysis of the diagnostic tools available by the meter, comparing the results obtained in laboratory and field. A methodology for determining estimates of measurement uncertainty of flow rate and totalize gas in a given time interval is proposed. Evaluations of compliance with the standards and the analysis of the diagnostic tools available show that the use of ultrasonic meters in the fiscal measurement of natural gas is technically feasible, and that, by varying the time for measuring volumes, the uncertainty of measurement can be quite reduced.
|